Advanced multilevel Inverter system

Maximum 98.6% efficiency

High voltage MPPT window: up to 950V

Featuring compact footprint: 1.33 m2

Featuring compact footprint


This advanced inverter design significantly reduces
size, achieving the smallest 630 kW inverter.

Grid Connection Features


TMEIC developed the grid connection features
working with Japanese power companies. All of
TMEIC’s utility scale inverters include the latest
Advanced Multilevel Inverter interconnection technology. These features include:
-56% of switching loss reduction • Power factor control
SOLAR WARE 630 redefines the PV utility scale • Reactive/Active power control
solar inverter solution in reliability, efficiency and • Fault ride through
productivity. TMEIC sets the standard of Utility - Voltage ride through (low voltage ride
scale installation with its own proprietary design through)
resulting the most advanced multilevel inverter - Frequency ride through
system by reducing the switching loss by 56%. • TMEIC’s proprietary anti-islanding technique
utilizes a slip mode frequency shift method

SOLAR WARE 630 Performance


SOLAR WARE 630 PVL-L630E
99
98 INV
52R
72B1
97
x8
Efficiency(%)

96
95 72B2

94 x8 Serial
Controller port Communication Unit PC
93
RS-232C .Modbus-TCP
92 .Ethernet(Socket)
.RS-485
91 PLC
550V-50Hz
90
LCD Panel
0 20 40 60 80 100
Load(%)
Type PVL-L0630E
Input Side Maximum DC Power 771kW
(DC) Maximum DC Voltage 1000V
MPPT Operating Range 540~950V *1
Maximum DC Current 1403A
Maximum Number of Input 16
Output Side Nominal AC Output Power 630kW
(AC) Nominal AC Voltage 380V 3-phase, 3-wire system
Nominal AC Frequency 50 / 60Hz
Nominal AC Currenct 957A
Power Factor >0.99 (Rated Power)
Harmonic Distortion of AC Current < 5% (Rated Power)
Maximum Efficiency 98.6%
European Efficiency 98.3%
Environmental Enclosure Protection Ratings IP2X (Indoors)
Conditions Relative Humidity 15% to 95% (not condensating)
Ambient Temperature Range -20 oC to + 50 oC (-4F to 122F) *2

Max. Altitude Above Sea Level 2000m


Protective Input (DC) Side Ground Fault, DC Reverse Current, Over Voltage, Over Current
Functions Grid (AC) Side Anti-islanding, Over/Under Voltage, Over/Under Frequency, Over Current
Grid Assistance Reactive/Active Power Control, Fault Ride Through, Power Factor Control
User Interface Local Control Panel LCD (3.8inch, QVGA) with Touch-Screen, Emergency Shut-off Button
Communications Ethernet (Socket / Modbus TCP), Serial (RS485 / RS232C)
Fault Analysis Fault Event Log, Waveform Acquisition via SD card
Compliance Low Voltage Directive: 2006/95/EC (EN50178)
EMC Directive: 2004/108/EC (EN61000-6-2, EN55011)
Cooling Method Forced air cooling
Inverter Dimensions (H x W x D) 2075mm x 1900mm x 700mm (81.7” x 74.8” x 28.7”)
Unit Weight 1300kg (2866lbs)
Note): *1:Transition mode between MPPT and constant DC voltage operation from 540 to 550V
o o
*2: Need optional heater below -10 C(14F) , Power de-rating over +40 C(104F)

75mm MAINTENANCE SPACE


3.0” AIR FLOW 300mm
11.8”

29.5mm
1.2”

EMERGENCY
STOP BUTON
2300mm
2075mm 90.5”
81.7” 1900mm
74.8”

VENTILATION
AIR FILTER
AIR FLOW

FLOOR LEVEL
100mm 500mm 900mm 500mm
3.9” 19.7” 35.4” 19.7” 30mm 700mm
DC INTERFACE INVERTER AC INTERFACE 1.2” 27.6”
1900mm 600mm 730mm
74.8” 23.6” 28.7”

FRONT VIEW RIGHT SIDE VIEW

TOSHIBA MITSUBISHI-ELECTRIC INDUSTRIAL SYSTEMS CORPORATION


Power Electronics Systems Division, Photovoltaic System Center
Email: info-pv@tmeic.co.jp • www.tmeic.co.jp
Contents subject to change without notice
TMEIC Corporation • Roanoke, Virginia • Email: info@tmeic.com • www.tmeic.com C-0039-1110-D(*)

Das könnte Ihnen auch gefallen