Beruflich Dokumente
Kultur Dokumente
Motorised switches
Gave Y Series motorised breakdowns. An increasing
changeover switches have been number of countries are approving
designed to perform distant new legislation involving backup
changeover operations. power sources on business and
They secure electromechanical administration installations open
reliability in all sort of applications: to public service. Therefore an
transfer supply-generator with or increasing number of installations
without break, main switch, reverse demand source changeover
switch, by-pass,... products covering this function.
Modern industrial and service Motorised changeover switches
companies require standby power are an ideal response to the
systems in order to avoid high practical requirements of remote
costs related to supply changeover operations.
Product overview
Standard Type Compact Type
Easy connection with sources Space limited installations can
input on top and load output use compact type motorised
on bottom. changeover switches that offer
up to 45% width reduction.
63-100-125A
160-200-250A
www.gave.com 83
Motorised changeover and
automatic transfer switches
Changeover
switching
Performant switching
technology providing
safety isolation, elevated
electrical endurance and
high make/break
capacity. Built-in internal
link integrates two
circuits.
Installation
Easy cable connection
on base mounted
product. No installation
Characteristics
Control terminals
Simple push-in
terminals controlling
the switch. Operations
counter
Compact motor block. 3 shaft pushes
Enabled security and blinking
against unstable digit will
supplies. indicate number
of operations.
Visual
indication
Digital position
readout. Manual
operation red
LED lights on.
Auxiliary
contacts
Operated with Manual
the same shaft operation
as power Possibility to
contacts. perform manual
backup
operation.
Padlockable handle
Up to 4 padlocks on
maintenance
conditions.
Protection
Screen
Suppllied from
origin on cable
lug connection
units.
www.gave.com 85
Motorised changeover and
automatic transfer switches
Dimensions
Changeover 25A
switches 86 86
62,5
30,5
61,5
133,5
64
55
129,3 24
86 86
62,5
30,5
61,5
133,5
64
55
137,3 24
104 194 24
92 81
125
92
16,5 10
195
112
112 88
146,5
97
265 112
112 88
178
165
Switches
144 178
112 112
112 88 112 88
146,5
178
165
97
www.gave.com 87
Motorised changeover and
automatic transfer switches
Reference system
2 25 A 6 63 A A 160 A
Position Rating
Y - 56 3 6 10 1
Version
Electrical scheme 0 automatic
Supply 1 automatic/manual
55x disconnector switch
56x changeover switch Poles 10 12V DC
57x changeover switch without 0 20 24V DC
54x changeover switch with overlapping 1 two poles 40 48V DC
640 star-delta 2 three poles 30 80 a 220V AC
671 motor reversing switch 3 four poles PV photovoltaic
application (12VDC)
Technical data
25A 32A 40A 63A 63A 100A 125A 160A 200A 250A
AC22
terminal
References
3 pole 4 pole 3 pole 4 pole
12V DC 230V AC 12V DC 230V AC 12V DC 230V AC 12V DC 230V AC
Special Applications
Cam technology provides great
flexibility on special applications, we
can add load break cells while keeping
with an extremely compact unit.
By-pass 3+6 or 4+8, motor starting,
motor reversing are typical applications
that can be conducted with motorised
switches that will allways offer local
manual operation when remote
operation overriding is necessary. Motor reversing Motor starting
www.gave.com 89
Motorised changeover and
automatic transfer switches
Automatic
A tom transfer switch (ATS)
Gave Yseries motorised Strong competition has made installations from small business to
changeover switches have been industries, commercial and service large scale facilities.
designed to perform distant companies increasingly dependent
changeover operations. on power supply. Preventing A comprehensive range of
consequences of power failure has
Automatic Transfer Switches has
become a critical element for
They secure electromechanical been developed by Gave based on
customer service and business
reliability in all sort of applications: profitability. his extensive experience on the
transfer supply-generator with Generator and auxiliary power field. Design has been done
or without break, main switch, supply systems have become considering installation
reverse switch, by-pass,... common place on modern requirements and user real needs.
Product overview
Enclosed Automatic Automatic Transfers
Transfer Switch Units Open Type
ATS + Measuring
Open Type
25-400A
25-250A
Special products
ATS
25-3200A
Special ATS
ATS + Emergency
25-3200A
www.gave.com 91
Motorised changeover and
automatic transfer switches
ATS
Automatic Transfer Switches
Gave Y Series motorised - Clutch mechanism detaches - Control electronics protected
changeover switches have been manual switching operation against surge overvoltage
designed to perform remote from motorised mechanism (optional on basic models).
changeover operations. (Y Series 40 to 250A). - Operating cycles timer
- Local padlockable handle for programmable.
According to standards
maintenance operations. - High peformance power
• IEC 60947-3 - Mechanical and electrical 0 supply protected against
• IEC 61000 position equipped from output shortcircuit.
origin. - Changeover power relays
General characteristics • Control element: with 3 pos. Manual button for
- Phase presence and test operations.
• Motorised changeover
sequence control. - Auxiliary contacts for external
- 2 And 4 pole changeovers.
- Voltage monitoring signalling and genset
- Ratings from 25A to 3200A.
thresholds adjustable. command.
- Local manual emergency
- Control elements fuse
operation.
protected.
System reference
25 A 100 A 400 A 1600 A
002 010 040 160
32 A 125 A 630 A 2000 A
003 012 063 200
40 A 160 A 800 A 2500 A
004 016 080 250
63 A 200 A 1000 A 3200 A
005 AC22 020 100 320
CA Enclosed automatic transfer switch 63 A 250 A 1250 A
PL Open automatic transfer switch
006 025 125
Serie Rating
CA 0 1 2 006 P
Model Version
1 control logic P Surge protector device*
2 control logic + synoptic mains/genset
No SPD protection
4 control logic + synoptic&measuring mains/genset
E emergency * included in measuring and emergency models
Poles
2 two poles
4 four poles
Functionality
Simple "Plug&Play"
transfer. Extensive
range covering
• Complete set: - Solid door fixed with two or multiple function
- Components integrated on three hinges. possibilities such as
metal steel enclosure IP55 - 3mm standard double bar signalling, measuring,
with embedded cable entry lock. Wide variety of lock emergency,...
plate with neoprene seal. transformations available.
- Foamed-in polyurethane - Ventilation and thermal
gasket guarantees solutions available.
Installation
Wall mounting panels
watertightness for years. - Terminal connection with
with large cable
- Fixing brackets, fastened with flexible cable up to 35mm2
entries and
screws from the outside, can on transfers ratings up to
straightforward
be placed horizontally or 125A.
terminal connection.
vertically. - Cable lug connection from
- Epoxy polyester texturised 160A up to 250A.
powder coating colour grey - Busbar connection on 400A Switching
RAL-7035. and above ratings. Well established
changeover switching
technology with
excellent electrical and
mechanical endurance
charateristics.
Control
User friendly logic
control easy to
program by adjusting
analogic rotary
selectors. Signalling
leds inform about
relays status.
Reliability
Local operation
guarantees safe
disconnection and
transfer operation
under all
circumstances.
www.gave.com 93
Motorised changeover and
automatic transfer switches
Characteristics
Control logic
Phase control relays and timers easy
configuration by frontal
potentiometers. Leds indicate relay
status.
Operation counter
Three pushes on shaft and display Overvoltage surge protector.
blinks 5 numbers indicating Control logic protected against
number of operations. lightning disturbances.
Manual operation
Embedded bottom plate. Integrated handle for local backup
Removable entry plate provides operation. Padlockable for safety
large accessibility. maintenance.
Auxiliary contacts.
Fuse protection External signalling and genset
Control logic fuse protected. command.
www.gave.com 95
Motorised changeover and
automatic transfer switches
Start
FAULT ` Genset GENSET
Grupo
Changeover to position 2
Industry and
Services
Stop MAIN
Genset SUPPLY
Changeover to position 1
up to 40 A
Logic overvoltage protected
Description A 2 poles 4 poles
2 poles 4 poles
ATS synoptic 40 CA022004 CA024004 CA022004P CA024004P
from 63 to 125 A
Logic overvoltage protected
Description A 2 poles 4 poles
2 poles 4 poles
ATS synoptic 63 CA022006 CA024006 CA022006P CA024006P
ATS synoptic 100 CA022010 CA024010 CA022010P CA024010P
ATS synoptic 125 CA022012 CA024012 CA022012P CA024012P
Dimensions
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2
FA
RF1 TM1 RF2 TM2
425
500
1 2 3 4 5 6 7
R0 S0 T0 N0 R S T N R1 S1 T1 N1
MANUAL
POSITION
230
500
425
www.gave.com 97
Motorised changeover and
automatic transfer switches
Dimensions
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2
FA 1 2 3 4 5 6 7
RF1 TM1 RF2 TM2
525
600
0
1 2
230
motorswitch
600
525
Dimensions
800
70
55
40
55
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2
1 2 3 4 5 6 7
25
25
400
17.5
M6X
120
105
25
90
96 55 35
596
50
Dimensions
A B
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2
1 2 3 4 5 6 7
A B
In (A) A B C
800-1600 A 800 600 1700
2000-3200 A 800 800 1700
www.gave.com 99
Motorised changeover and
automatic transfer switches
up to 40 A
Description A 2 poles 4 poles
ATS + Measuring 40 CA042004 CA044004
Dimensions
525
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2
FA
RF1 TM1 RF2 TM2
525
600
L1 L2 L3 N
R0 S0 T0 N0 R S T N
230
MANUAL
POSITION
1 2 3 4 5 6 7
R1 S1 T1 N1
600
from 63 to 125 A
Description A 2 poles 4 poles
ATS + Measuring 63 CA042006 CA044006
ATS + Measuring 100 CA042010 CA044010
ATS + Measuring 125 CA042012 CA044012
Dimensions
600
525
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2 RL
FA 1 2 3 4 5 6 7
600
L1 L2 L3 N
POSITION MANUAL
rojo/red: replace rojo/red: replace rojo/red: replace N/PE
R0 S0 T0 N0 R S T N 0
1 2
motorswitch
230
R1 S1 T1 N1
600
Dimensions
600
525
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2 RL
FA 1 2 3 4 5 6 7
600
1 2
230
motorswitch
PST-N
IEC61643-1
400V
20kA
T2 Imax 40kA
1.5V
N
EN61643-11
N/PE
Up
Uc
In
rojo/red: replace
PST-40
IEC61643-1
250V
230V
20kA
40kA
1.5V
L3
T2 Imax
EN61643-11
Up
Un
Uc
In
rojo/red: replace
PST-40
IEC61643-1
250V
230V
20kA
40kA
1.5V
L2
T2 Imax
EN61643-11
Up
Un
Uc
In
rojo/red: replace
PST-40
IEC61643-1
250V
230V
20kA
40kA
1.5V
L1
T2 Imax
EN61643-11
Up
Un
Uc
In
600
www.gave.com 101
Motorised changeover and
automatic transfer switches
Main characteristics
Signalling
Identify Control
System diagram
Initial status. Mains supply OK.
Phase control relay RF1 detects failure on Mains supply. Yellow
pilot lights on.
Volt free output contact changes status commanding Generator
start. Changeover switches to position 0. Blue pilot lights on.
Phase control relay RF2 detects Genset output is OK.
Timer TM1 delays transfer to Genset.
Transfer to Genset is operated. Position 0 blue pilot lights off.
Genset green pilot lights on.
Failure on Mains supply is over.
Timer TM2 counts return time before retransfer.
Retransfer is operated and output contact returns to intial status
commnanding Genset stop.
Grupo
Changeover position 2
Industry and
services
STOP MAIN
GENSET SUPPLY
Changeover position 1
Emergency stop Emergency stop. Push latching mushroom with trigger action according to EN 418.
Changeover switchs to position 0 with priority from its current position or logic. Blue
pilot lights on indicating changeover switch on position 0 and red pilot lights on
indicating emergency stop.
Turn mushroom to release. Automatic transfer command return to logic control.
www.gave.com 103
Motorised changeover and
automatic transfer switches
from 63 to 125 A
Description A 2 poles 4 poles
ATS + emergency 63 CA0E2006 CA0E4006
ATS + emergency 100 CA0E2010 CA0E4010
ATS + emergency 125 CA0E2012 CA0E4012
Dimensions
525 525
75 75
F1 F2 F3 F4 R1 RS R3 F5 F6 F7 F8 R2 F1 F2 F3 F4 R1 RS R3 F5 F6 F7 F8 R2
525
600
L L L N L L L N
POSITION MANUAL
R1 S1 T1 N1 1 2 3 4 5 6 7 0 1 2 3 4 5 6 7
R0 S0 T0 N0 R S T N R0 S0 T0 N0 R S T N R1 S1 T1 N1
MANUAL
POSITION
1 2
230
motorswitch
FA
FA
BAT
BAT
600
Dimensions
525
F1 F2 F3 F4 R1 RS RL F5 F6 F7 F8 R2
BA 1 2 3 4 5 6 7
600
FA
1 2
230
motorswitch
PST-N
IEC61643-1
400V
20kA
T2 Imax 40kA
1.5V
N
EN61643-11
N/PE
Up
Uc
In
rojo/red: replace
PST-40
IEC61643-1
250V
230V
20kA
T2 Imax 40kA
1.5V
L3
EN61643-11
Up
Un
Uc
In
rojo/red: replace
PST-40
IEC61643-1
250V
230V
20kA
T2 Imax 40kA
1.5V
L2
EN61643-11
Up
Un
Uc
In
rojo/red: replace
PST-40
IEC61643-1
250V
230V
20kA
T2 Imax 40kA
1.5V
L1
EN61643-11
Up
Un
Uc
In
600
Dimensions
800
70
55
40
55
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2
1 2 3 4 5 6 7
25
25
400
17.5
M6X
120
105
25
90
96 55 35
596
50
Dimensions
A B
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2
1 2 3 4 5 6 7
In (A) A B C
800-1600 A 800 600 1700
2000-3200 A 800 800 1700
C
www.gave.com 105
Motorised changeover and
automatic transfer switches
up to 40 A
Description A 2 poles 4 poles
Basic ATS Open Type 40 PL012004 PL014004
from 63 to 125 A
Description A 2 poles 4 poles
Basic ATS Open Type 63 PL012006 PL014006
Basic ATS Open Type 100 PL012010 PL014010
Basic ATS Open Type 125 PL012012 PL014012
Dimensions
75 75
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2
FA
RF1 TM1 RF2 TM2
FA
RF1 TM1 RF2 TM2
450
550
POSITION MANUAL
1 2 3 4 5 6 7
R0 S0 T0 N0 R S T N R1 S1 T1 N1
MANUAL
POSITION
1 2 3 4 5 6 7
R0 S0 T0 N0 R S T N R1 S1 T1 N1
0
1 2
motorswitch
450
550
Dimensions 75
F1 F2 F3 F4 R1 RS F5 F6 F7 F8 R2
FA 1 2 3 4 5 6 7
1 2
motorswitch
550
www.gave.com 107