0 Bewertungen0% fanden dieses Dokument nützlich (0 Abstimmungen)
2K Ansichten1 Seite
This document summarizes the calculation of stresses on a pipe support connecting a 16" header to a 14" trunnion. The maximum combined circumferential stress on the header is calculated to be 99.8 N/mm2, which is 49% of the allowable stress of 205.5 N/mm2. This indicates the header stresses are acceptable. Additionally, the unity check calculation for the 14" trunnion results in a value of 0%, which is less than the allowed value of 1.0, indicating the trunnion unity check is also acceptable. Therefore, both the header and trunnion stresses are within allowable limits based on this calculation.
This document summarizes the calculation of stresses on a pipe support connecting a 16" header to a 14" trunnion. The maximum combined circumferential stress on the header is calculated to be 99.8 N/mm2, which is 49% of the allowable stress of 205.5 N/mm2. This indicates the header stresses are acceptable. Additionally, the unity check calculation for the 14" trunnion results in a value of 0%, which is less than the allowed value of 1.0, indicating the trunnion unity check is also acceptable. Therefore, both the header and trunnion stresses are within allowable limits based on this calculation.
Copyright:
Attribution Non-Commercial (BY-NC)
Verfügbare Formate
Als XLS, PDF, TXT herunterladen oder online auf Scribd lesen
This document summarizes the calculation of stresses on a pipe support connecting a 16" header to a 14" trunnion. The maximum combined circumferential stress on the header is calculated to be 99.8 N/mm2, which is 49% of the allowable stress of 205.5 N/mm2. This indicates the header stresses are acceptable. Additionally, the unity check calculation for the 14" trunnion results in a value of 0%, which is less than the allowed value of 1.0, indicating the trunnion unity check is also acceptable. Therefore, both the header and trunnion stresses are within allowable limits based on this calculation.
Copyright:
Attribution Non-Commercial (BY-NC)
Verfügbare Formate
Als XLS, PDF, TXT herunterladen oder online auf Scribd lesen
Job №: 119784 Area: 46 Line Number: 46-SM-1111-1CS1S02H1-4"-IH
GA №: Stress Sketch Number:
INPUT DATA: Metric or Imperial Sizes : IMP
Nominal Pipe Size = 16" (400) Diameter (D) = 406.4 mm Radius (R) = 203.2 mm (inc. rolling Nominal Thickness (T) = 12.7 mm Pipe Minimum Thickness = 9.513 mm tolerance)
Corrosion Allowance = 1.6 mm Effective Wall Thickness (t) = 9.513 mm
Nom.Trunnion Size = 14" (350) Diameter (d) = 355.6 mm Radius (r) = 177.8 mm
Trunnion Wall Thickness = 9525 mm Longitudinal Force (Fl) = 2360 N
Pad Nominal Thickness = 0 mm Circumferential Force (Fc) = 2434 N Moment Arm (L) = 700 mm Direct Axial Load (Fa) = 33256 N Max Design Pressure (P) = 28 bar Maximum Operating Temp. = 150 C° Material Type = CS Allowable Stress (Sh) =. 137 N/mm²