CONTENT
2 EOCR-SS Electronic Overload Relay
3 EOCR-SP1/SP2 Electronic Overload Relay
3 EOCR-SP40 Electronic Overload Relay
4 EOCR-DS Electronic Overload Relay
5 EOCR-SSD Digtal Over-current Relay
6 EOCR-3DE/3EZ Digtal Over-current Relay
9 EOCR-3DM/3MS/3MZ Digtal Over-current Relay
12 EVR Electronic AC Voltage Relay
12 EVR-PD Digtal AC Voltage Relay
13 EGR Electronic Ground Fault Relay
13 PMR-44 Electronic Phase Monitoring Relay
14 EOCR-1P Single Phase Relay
15 EOCR-DZ(T) Electronic Ground Fault Relay
16 DCL/DUCR Electronic DC Current Relay
16 DOVR/DUVR Electronic DC Voltage Relay
17 2CT Current Transformer
17 3CT Current Transformer
17 ZCT Current Transformer
18 Dimension
20 LR97D/LT47 Electronic Over Current Relay
24 LR9F Electronic Thermal Overload Relay
28 GMP Electronic Overload Relay
38 3RB20 Electronic Overload Relay
40 RST25 Electronic Overload Relay
www.junxele.com
JUNXELE EOCR-SS
Electronic Overload Relay
Specification
Current setting Type Range Phase Loss Protection Straight-through-Wiring Looping Option(1-Loop)
05 0.5 - 6A
30 3 - 30A During a phase loss, the motor winding current may External Current Transformer Option
60 5 - 60A increase by 150% or more.
100~(over 60A) Ext. CT Option As the motor winding current increases, the winding Ordering option - 05 type of each model fitted to
Time Start D-TIME 0.2 - 30 sec temperature may also increase and possibly damage an external current transformer can achieve higher
Setting Trip O-TIME 0.2 - 10 sec the winding insulation. ampere ranges. (Ext. CT Option)
Control Voltage 220 90 - 260VAC The quick trip time on EOCR helps to prevent over- Type Current Ratio Current Setting
(50/60Hz) 440 320 - 480VAC current damage to the windings. of Ext. CT Range
Output Relay Mode 1-SPDT(1C) 05 - 0.5 - 6A
Rating 3A/250VAC Resistive 100 100:5 10 - 120A
Ext. CT 200 200:5 20 - 240A
Status Normally Energized 300 300:5 30 - 360A
Option
Time-Current Characteristic Definite 400 400:5 40 - 480A
Operating (Trip) Indication 2-LED 500 500:5 50 - 600A
Mount 35mm Din-rail / Panel 600 600:5 60 - 720A
Typical Wiring ss
2 www.junxele.com
JUNXELE EOCR-SP1 / SP2
Electronic Overload Relay
■
2 Integral Current Transformers
■
Fits Directly into IEC or NEMA Contactor
Protection
EOCR Operating (Trip) Time
Protective Item
SP1 SP2
Over-current O-TIME(curve) 5sec
Phase Loss 4sec 4sec
EOCR-SP1/SP2 Locked Rotor O-TIME+10sec D-TIME
Time Characteristic Inverse Definite
Typical Wiring
Specification
EOCR SP1 SP2
Current Setting 01 0.3 - 1.2A 03 - 1.2A
10 1 - 12A 1 - 12A
20 5 - 25A 5 - 25A
Time Start D-TIME 10 sec(Fixed) 1 - 50 sec
Setting Trip O-TIME 1 - 10 5 sec(Fixed)
Control Voltage 110 85 - 150VAC
(50/60Hz) 220 180 - 260VAC
Mode 2-SPST
Output Relay Rating 3A/250VAC Resistive
Status Normally Energized
Time-Current Characteristic Inverse Definite
Trip & Trip Cause Indication 2-LED
Mount Contactor Mounted
EOCR-SP40
Electronic Overload Relay
■
3 Integral Current Transformers
■
Electrcnic Shear-pin Function
■
Independently Adjustable Staring Trip Delay(D-Time)&Trip Time(O-Time)
■
Fits Directly into IEC or NEMA Contactor
Protection
EOCR-SP40 Protective Item Operating (Trip) Time
Over-current O-TIME
Phase Loss O-TIME
Locked Rotor O-TIME + D-TIME
www.junxele.com 3
JUNXELE EOCR-DS/DST
Electronic Overload Relay
Protection
Protective Item Operating (Trip) Time
Over-current O-TIME
EOCR-DS EOCR-DST Phase Loss O-TIME
Locked Rotor O-TIME + D-TIME
4 www.junxele.com
JUNXELE EOCR-SSD
Digital Over-Current Relay
Protection
Specification
■
MCU(Micro Controller Unit) based / 2-CT Type
■
Real Time Processing / Higher Precision
■
Current Setting Range - 05Type : 0.5 ~ 6A / 30Type : 3 ~ 30A / 60Type : 10 ~ 60A
■
Digital display : trip cause / easy troubleshooting
■
Reset : Manual (instantaneous) / Electrical (remote)
■
Load selection by DIP switch : Single phase(1P) / Three phase(3P)
■
Fail safe(N) / Non-fail safe(R)
www.junxele.com 5
JUNXELE EOCR-3DE/3EZ
Digital Over-Current Relay
■
MCU Based
■
3 Integral Current Transformers
■
Over-current, Under-Current, Phase Loss, Phase
Unbalance, Phase Reversal, Locked Rotor Protection
■
Digital Ammeter & Trip cause indication
■
Selectable Trip Time-Current Characteristics
■
Independently Adjustable Starting Trip Delay and Operating
■
Trip Time
+ Load Alerting Function → EOCR-3DE
+ Ground Fault Protection → EOCR-3EZ
Protection
EOCR-3DE/3EZ EOCR-3DE EOCR-3EZ
Protective Item Trip Time Protective Item Trip Time
Over-current O-TIME Over-current O-TIME
Typical Wiring under-current 0.5~30sec Under-current 0.5~30sec
Phase Loss 3 sec Phase Loss 3 sec
Phase Unbalance 8 sec Phase Unbalance 8 sec
Phase Reversal 0.1~0.3 sec Phase Reversal 0.1~0.3 sec
Locked Rotor D-TIME Locked Rotor D-TIME
- - Ground Fault 0.05~10 sec
Specification
Model EOCR-3DE EOCR-3EZ
Over Current Setting Range Refer Table #1
Ground Fault Current Setting - 0.02 ~ 3A
Alert Setting 50 ~ 100% / OFF -
Start Delay Time Setting (D-TIME) 1 ~ 200 Sec
Trip Delay Time Setting (O-TIME) INV 1 ~ 30
DEF 0.2 ~ 30 Sec
Control Voltage 24VAC/DC, 110VAC±15%, 220VAC±15%
Output Relay OL 2-SPST 1-SPST
AL/GR AL Relay Ground Fault Relay
Rating 3A/250VAC Resistive
Time Characteristic In/”tc”mode Inverse (See Curve-1)
EOCR-3DE dE/”tc”mode Definite (See Curve-2)
Troubleshooting / Trip Indication LED Display (SSD+LED)
Current Sensing 3-CT
Mounting 35mm Din-rail
6 www.junxele.com
JUNXELE EOCR-3DE/3EZ Series
Digital Over-Current Relay
…
● ●
Under - current ● ● 800 : 5 800 80 ~ 960A
Phase Loss ● ●
EOCR-3DE+Extemal CT
Phase Unbalance ● ● Alert Function
Phase Reverse ● ● When motor operating current (In) exceeds the alert setting (As), the alertrelay
Locked Rotor ● ● outputs three kind of signal. The output can be used to warn customers/
Ground Fault - ● operators of possible overloading and avoid unnecessary motor shutdown.
Run Monitor & Load Alert Function ● - The type of output signal is decided by the selection in the “Alo” mode
Selectable Alerting Pulse ● - “A”(Ampere relay): energized whenever CT senses a current
“F”(Flickering): character“A” and current value flashs frequently
Protection Feature “H”(Holding): ON-OFF
“U”(Undercurrent mode): the “AL” output(07┫┣08) is transferred into
Function Mode Description “Uc” output
dE This is provided by the relay tripping when motor operating
current(In) exceeds current setting value in “oc” mode for a
Running state More then
(Definite Normal preset(%) of Alert Trip
period greater than the preset trip time(O-Time in “ot” mode) Setting“ALo”
T-C) (Curve-2)
Over-
tc Flicker“F”
current In This is provided by the relay tripping when motor operating
(Inverse current(In) exceeds current setting value in “oc” mode
T-C) according to the Time-current Characteristic Curve(Curve-1) Hole“H” 2sec
This is provided by the relay tripping when motor operating
Under- Definite current(In) is lower than current setting value in “uc” mode Aux“A”
Uc
current T-C for a perid greater than the preset trip time(Time in “ut”
mode) In = Motor Operating Current / Is = EOCR Over-current Setting / As = Alert
Phase The relay will be operated within 3sec. When the phase failure Setting
PL On
Loss occurs
Fail-safe & Non-fail-safe
This is provided by the relay tripping in phase unbalance
Phase greater than setting % difference in terms of maximum phase The tripping relay can be operated in a fail-safe or non-fail-safe mode
Ub 5~50%
Unbalance current : [(MAX-MIN)/MAX]×100[%]
On In the event of phase reversal, the relay trips in 0.1sec Application of the Fail-safe (Electrically Held) Connection
Phase RP Phase reversal protection function is disabled : this allows the
Reversal Off(--) Faye safe setting in“FS” mode : ON
relay to be used for reversing application
The tripping relay is normally energized with control power supply
Ground Ground fault protection is provided by the relay tripping
Fault Ec 0.03~3A accoding to zero sequence current sensed by ZCT Application of the Non-fail-safe Connection
This is a protection for locked rotor in starting state.The variable
2~10 setting range is 2~10 times oc setting value, but maximum
Fail safe setting in “FS” mode: OFF(--)
Locked In all cases, the failure of the control voltage may not interrupt the process.
Lc Times setting value is limited in case“oc” setting value is greater
Rotor
than 10A. The maximum setting value is calculated by [100/oc
OC
setting value]
www.junxele.com 7
JUNXELE EOCR-3DE/3EZ
Digital Over-Current Relay
■ Over-current Trip
Relay displays a trip, caused by over-current.
which has been detected from phase L1(R/T1).
■ Under-current Trip
Relay displays a trip, caused by under-current.
Digital Ammeter which has been detected from phase L2(S/T2).
3 phase motor currents (In) / Ground fault current are displayed in ■ Phase Loss Trip
sequence on the LED display. Relay displays a trip, caused by phase loss
■ 3DE (Phase Failure) on Phase L2(S/T2)
- Enter into “trip” mode by depressing once Set/store button, then last trip 6-10 10
cause is showed 11-20 20
- Each phase current is displayed in order whenever depress UP/DN button in 21-30 30
every once under trip mode
- The 2nd trip cause is showed after displaying 3phase current of last trip
- The 3rd trip can be checked by same manner
Test
This is the self-test of this product. If the relay enters into this mode, it begins
to count down preset value of O-time after wating 3sec and becomes trip state
as showing “END” message that means this relay is ready to work.
- “END” message of this test is also stored in “Fault” mode as last trip.
- Not permitted to test this function during the operation to prevent
unnecessary trip
Reset
Depressing the RESET button or interrupting control power resets the relay
immediately. Electrical remote reset is also available through the panel
mounted reset switch.
8 www.junxele.com
JUNXELE EOCR-3DM/3MS/3MZ
Digital Over-Current Relay
■
Over-current, Under-current, Phase Loss,
Phase reversal,Phase Unbalance, Locked rotor
protection
■
Short current protection ← 3MS
■
Ground Fault Protection ← 3MZ
■
Including Current Transducer : 4~20mA output
■
Accumulation to Running time
EOCR-3DM
Protection
Trip Time
Protective Item 3DM 3MS 3MZ
Over-current DEF: 0.2 ~ 30sec, INV: 1 ~ 30 DEF: 0.2 ~ 30sec, INV: 1 ~ 30 DEF: 0.2 ~ 30sec, INV: 1 ~ 30
Under-Current 0.5 ~ 30sec(DEF) 0.5 ~ 30sec(DEF) 0.5 ~ 30sec(DEF)
Phase loss 3sec 3sec 3sec
Phase reversal 0.1sec 0.1sec 0.1sec
Phase Unbalance 8sec 8sec 8sec
Locked Roter Lock 0.5sec after dt 0.5sec after dt 0.5sec after dt
Stall 1 ~ 10sec 1 ~ 10sec 1 ~ 10sec
Ground fault - - 0.1 ~ 10sec
Specification
Model 3DM 3MS 3MZ
Current Setting Over-Current(oc) Refer to, Table #1 Refer to, Table #1 Refer to, Table #1
Range Under-Current(uc) 0.5 ~ under OC setting 0.5 ~ under OC setting 0.5 ~ under OC setting
Ground Fault Current(Ec) - - A : 0.03 ~ 2.5A / B : 0.5 ~ 10A
Time Setting Starting Delay Time(dt) OFF ~ 200sec OFF ~ 200sec OFF ~ 200sec
Over-Current Trip Delay(ot) DEF : 0.2 ~ 30sec / INV : 1 ~ 30 DEF : 0.2 ~ 30sec / INV : 1 ~ 30 DEF : 0.2 ~ 30sec / INV : 1 ~ 30
Under-Current Trip Delay(ut) 0.5 ~ 30sec(DEF) 0.5 ~ 30sec(DEF) 0.5 ~ 30sec(DEF)
Ground Fault Trip Delay(Et) - - 0.1 ~ 10sec
Control Power 220 85 ~ 250VAC/DC, 50/60Hz 85 ~ 250VAC/DC, 50/60Hz 85 ~ 250VAC/DC, 50/60Hz
Output Relay OL 2-SPST, 3A/250VAC, Resistive 2-SPST, 3A/250VAC, Resistive 1-SPST, 3A/250VAC, Resistive
AL(GR/SC) 1-SPST(AL) 1-SPST(S.C) 1-SPST(GR)
Environment Temperature Store -30℃ ~ 80℃ -30℃ ~ 80℃ -30℃ ~ 80℃
Operation -20℃ ~ 60℃ -20℃ ~ 60℃ -20℃ ~ 60℃
Humidity 30 ~ 85RH, Without condensation 30 ~ 85RH, Without condensation 30 ~ 85RH, Without condensation
Display 7-Segment LEDs ○ ○ ○
Bar-Graph ○ ○ ○
Mounting 35mm Din-rail 35mm Din-rail 35mm Din-rail
www.junxele.com 9
JUNXELE EOCR-3DM/3MS/3MZ
Digital Over Current Relay
Phase on : enable
In the event of wrong phase sequence, relay will be operated in 0.1sec. ※Tolerance (3DM/ FDM / EVR Series)
Reversal Phase reversal protection function can be disabled by DIP selection.
off : disable
I<1A : ±0.1A
Current
I≥1A : ±5%
A Type: Ground fault protection is provided by the relay tripping sensed by
Ground 0.03-2.5A Zero Phase Current Transformer (Core Balanced Current Transformer) 0.05s → Within 0.05s
Fault B Type : The relay shows the leakage current during operation
Time t<1s : ±0.1s
0.5-10A (3MZ & FMZ)
t≥1s : ±5%
The setting range is 2-10 times of oc setting.
Locked If the starting current exceeds more than setting value after preset
Rotor D-Time elapses, the relay will be energized within 0.5sec.
This function is available on definite time characteristic.
10 www.junxele.com
JUNXELE EOCR-3DM/3MS/3MZ
Digital Over Current Relay
■ Over-current Trip
Relay displays a trip, caused by maximun over-current.10.7A
which has been detected from phase L3(T/T3)
■ Under-current Trip
Relay displays a trip, caused by minimum Under-current.
1.14A which has been detected from pfase L2(S/T3)
Digital Ammeter ■ Locked Rotor Trip
Relay displays a trip, caused by locked rotor and maximum
3 phase motor currents(In) are displayed in sequence on the LED display.
current. 26.9A which has been detected from pfase L1(R/T1)
3DM
■ Locked Rotor Trip
Relay displays a trip, caused by locked rotor while
motor is working
3MZ
■ Phase Loss Trip
Relay displays a trip, caused by phase loss which has been
detected from phase L2(S/T2)
■ Phase Loss Trip
Relay displays a trip, caused by phase loss which has been
detected from phase L3(T/T3)
■ Ground Fault Trip
Ground Fault Trip Relay displays a trip, caused by ground
fault current 0.6A which has been detected from ZCT
- Enter into “FAULT” mode with mode switch by depressing once Set/ Select the mode to adjust with turning
store button, then last trip cause is shown MODE
the MODE/Adjust swith CW or CCW.
- Each phase current is displayed in order whenever turn mode switch right
or left Depress the SET/store button once to
Set
start the setting
Test
This is the self-test of this product. If the relay enters into this mode, it begins Adjust the required amount with MODE/
Adjust
its count down preset value of O-time of “Ot” mode after waiting 3sec and Adjust switch
becomes trip state as showing “END” message that means this relay is
ready to work. Store Depress the SET/store button once to
- “END” message of a result of this test is also stored in “Fault” mode as memorize the setting
last trip.
- Not permitted to test this function during the operation to prevent
unnecessary trip
Reset
Pushing the RESET button or interrupting power resets the relay immediately.
Electrical remote reset is also available through the panel mounted reset
switch. The relay cannot be reset by control power interruption when the hand
reset (H-r) selected in mode.
In this case, it is possible to press the reset button on the relay facia.
Automatic reset is also available if enter into reset mode (rt:A-r) and
reset delay time is adjustable from 0.3sec to 20min
www.junxele.com 11
JUNXELE EVR
Electronic AC Voltage Relay
Features
■
Compact Design ■
Trip Indication & Troubleshooting → Ascertain Button
■
Multiple Protection Functions ■
Manual / Electrical Reset
■
24 Hours Trip Cause Memory ■
Ambient Insensitive
Protection
Protective Item Trip Time
Over-voltage OVR-TIME
Under-voltage UVR-TIME
Phase Loss 0.5 sec
EVR Phase Reversal 0.5 sec
Specification
Typical Wiring EVR - 220 EVR - 380 EVR - 415
Rated Voltage
220V 380V 415V
Voltage Setting OVR-VOLT 220 - 300V 380 - 460V 415 - 500V
UVR-VOLT 160 - 220V 300 - 380V 340 - 415V
Trip Time Setting OVR-TIME 0.5 - 2 sec
UVR-TIME 1 - 5 sec
Phase Loss Trip Time within 0.5 sec
Phase Reversal Trip Time within 0.5 sec (after Supply Power)
Time-current Characteristic Definite
Output Relay 1-SPDT(1C), 5A/250VAC Resistive
Reset M Manual Reset
A Automatic Reset (Reset Time = 5 sec)
Test Trip in 1 sec (after Pushing TEST Button)
ASCERTAIN S/W Trip Cause is memorized for 24 hours and
(Trip Cause Indication) Trip Cause will be indicated via LED
by pushing Ascertain S/W.
Allowable Tolerance Voltage ±5%
Time ±15%
EVR-PD
Digital AC Voltage Relay
Features
■
MCU & ASIC Based Compact Design ■
Trip Cause Display & Easy Troubleshooting
■
Multiple Protection Functions ■
Manual / Electrical / Automatic Reset
■
Wide Voltage Adjustment Range ■
Adjustable Reset Timer
■
Digital Volt Meter and Digital Setting ■
Ambient Insensitive
Protection
EVR-PD Protective Item Trip Time (EVR-PD)
Over-voltage OVR-TIME
Under-voltage UVR-TIME
Typical Wiring Phase Loss 2 sec
Phase Reversal 0.1 sec
Voltage Unbalance 3 sec
Specification
Voltage Setting Type Over-voltage (O-VOLT) Under-voltage (U-VOLT)
110 110 - 150V 80 - 120V
220 220 - 300V 160 - 240V
440 380 - 500V 300 - 440V
Trip Time Setting O-TIME 0.5 - 10 sec
U-TIME 0.5 - 10 sec
Control Voltage 220 AC/DC85 - 250V
Others AC/DC24, 48V (Optional Order)
Output Relay Mode 1-SPDT(1C)
Rating 3A/250VAC Resistive
Status Normally Energized
Reset SW3=AUTO Reset Time: 1 or 5 sec (DIP-SW4)
SW3=MAN RESET Button
Mounting PD 35mm Din-Rail / Panel
12 www.junxele.com
JUNXELE EGR
Electronic Ground Fault Relay
Features
■
MCU Based Compact Design ■
Trip & Run Indication LED
■
Ground Fault Protection with ZCT ■
Manual / Electrical Reset
Protection
Protective Item Trip Time
EGR Ground Fault O-Time
Specification
Typical Wiring
Ground Fault (GF) Type Range
Current Setting 05 50 - 500mA
10 100 - 1,000mA
20 200 - 2,500mA
Trip Time Setting O-TIME 0.2 - 2.0 sec
Reset Manual / Electrical (Push RESET Button or Interrupt
Supply Power)
Power Suppy 110 / 220VAC, 50/60Hz
Output Relay Mode/Rating 1-SPDT(1C), 3A/250VAC Resistive
Status Normally De-energized
Mounting 35mm DIN-Rail / Panel
PMR-44
Electronic Phase Monitoring Relay
Features
■
MCU Based Compact Design ■
Trip Cause Indication & Troubleshooting
■
Multiple Protection Functions ■
Manual / Electrical / Automatic Reset
■
2 - 15% Voltage Unbalance Setting ■
Ambient Insensitive
■
Fail-safe Operation
Protection
Protective Item Trip Time
Phase Reversal 0.1 sec
Phase Loss 1 sec
Voltage Unbalance 5 sec
Specification
Control Voltage Type Range
220 3Φ 160 - 300VAC, 50/60Hz
PMR-44 440 3Φ 340 - 480VAC, 50/60Hz
Reset Manual (Instantaneous) / Electrical
Automatically reset with 5 sec delay
when supply power comes to normal.
Output Relay Mode 1 - SPDT (1C)
Typical Wiring Rating 5A/250VAC Resistive
Status Normally Energized
Mounting 35mm DIN-rail/Rail
Troubleshooting
www.junxele.com 13
JUNXELE EOCR-1P
Single Phase Relay
Features
■
Single-phase Over Current Protection
■
Trip Indication LED
■
Definite Trip time Characteristic
■
Mamual (instantaneous)/Electrical (Remote) Reset
Protection
Protective Item Operating (Trip) Time
EOCR-1P
Over-current O-TIME
Specification
14 www.junxele.com
JUNXELE EOCR-DZ(T)
Electronic Ground Fault Relay
Features
■
MCU Based
■
Ground Fault/ Over-Current/Phase Loss/Phase Umbalance/Phase Reverse/Locked Rotor
■
Definite Trip time characteristic
■
Manual(Instantaneous)/Electrical (Remoter)Reset
■
Trip Indication LED
■
DZ: Window Type Terminal Type
■
EOCR-DZ+Power Terminal Kit→EOCR-DZT
Protection
Protective Item Operating(Trip)Time
Over-current O-TIME
Phase Loss 4sec
EOCR-DZ
Phase Reverse 0.1sec
Phase Unbalance 8sec
Locked Rotor 10sec
Ground Fault 0.5sec
Specification
EOCR-DZ(T)
Type Range Ground Fault
Current Setting 05 0.5~6A 0.05~0.8A
10 1.0~10A 0.05~0.8A
60 5.0~60A 0.05~0.8A
60~600 0.5 Type fitted with external CT. 0.05~0.8A
Time Setting Start-Up Delay D-TIME
Operating Delay O-TIME 30sec
RESET Manual Reset/Electrical(Remote) Reset
Time Characteristics Definite
Trip Indication 5LED
Tolerance Current ±10%
EOCR-DZT
Time ±10%
Control Voltage Voltage 110 AC85~150V,50/60Hz
220 AC180~260V,50/60Hz
Output Contacts 1-SPDT AC 250V/3A/250VC
Contacts R Type Normally Energized: 97┦┟98 Colsed
Condititon
N Type Normally De-energized: 95┦┟96 Colsed*Optional
Insulation Between Casing & Circuits Over 10MΩ(DC 500V Mugger)
Between Casing & Circuits 2kV 50/60Hz 1min
Dielectric Strength Between Contacts 1kV 50/60Hz 1min
Between Circuits 2kV 50/60Hz 1min
Storage -20~60℃
Ambient Temperature
Operation -30~80℃
Ambient Humidity 30~85%RH without Condensation
Mouting EOCR-DZ Panel
EOCR-DZT 35mm Din-Rail/Panel
www.junxele.com 15
JUNXELE DCL/DUCR
Electronic DC Current Relay
Features
■ DC Overcurrent Relay for DC Motor delay. It has easier control operation. It has DC
■ The milli-volt(mV) signals generated from Overload and DC Underload protection relays.
the Shunt and power supply are sensed by ■
It has wide DC current protection range from
solid state circuitry and compared with preset 1A to hundreds Amps.
overload setting. ■
DC Ammeter maybe used instead of Shunt
In case sensing overload condition, the (DC Ammeter has its own shunt inside and
internal relay switches contact after the preset keep 50mV maintained.)
DUCR
Protection
Protective Item DCL DUCR
Typical Wiring Over-current O-TIME -
Under-current(Dry-run) - O-TIME
Specification
Current Setting Type Setting Range(DCL) Setting Range(DUCR)
DC Over-current Relay DC Under-current Relay
70 Secondary Voltage of Shunt(10~70m VCD)
Trip time setting O-TIME 30sec(Adjustable)
Reset M Manual(Instantaneous) / Electrical(Remote)
A Auto(Instantaneous) Reset(Option)
Indication LED
Power Supply Voltage 220 110/220VAC
Other Voltage(Option)
440 380/440VAC
Frequency 50/60Hz
Auxiliary Relay N Normally Energized
R Normally De-energized
Mounting Panel
DOVR/DUVR
Electronic DC Voltage Relay
Features
■
Compact Design ■
Solid State DC Over-voltage / Undervoltage
■
Definite Trip Time-current Characteristic Protection.
■
Trip & Run Indication (LED)
■
Confirm actual current and precise setting
possible as it has Voltage Meter.
DOVR Protection
Protective Item DOVR DUVR
Typical Wiring Over-voltage O-TIME -
Under-voltage - O-TIME
Specification
Model DC Over-voltage DC Undervoltage
Voltage Setting Type Voltage Setting Range
10 1~10V -
30 3~30V 3~30V
110 10~110V 20~110V
220 20~220V 30~220V
Others Option
Trip Time Setting Trip Delay O-TIME 0.2~30sec
Reset M Manual(Instandaneous)/Electrical Rester
A Auto(Option)
Control Voltage 220 110/220VAC, 50/60Hz
Others Other voltage option
Auxiliary Relay Mode/Rating 1-SPDT(1C) 3A/250VAC Resistive
Status R Type Normally De-energized
Mounting Panel
16 www.junxele.com
JUNXELE 2CT
Current Transformer
Features
■
Fitted to EOCR relays for Large Amp Motor Protection
■
1.0 Measuring Class
■
For EOCR Only
Specification
Model 2CT-100 2CT-150 2CT-200 2CT-300 2CT-400
Current Ratio 100 : 5A 150 : 5A 200 : 5A 300 : 5A 400 : 5A
Class 1.0 1.0 1.0 1.0 1.0
Budden 5VA 5VA 5VA 5VA 5VA
2CT
Insulation Voltage 600VAC
Dielectric Strength 2kV
Insulation 10MΩ(500VDC Mugger)
Mounting Panel
3CT
Current Transformer
Features
■
Fitted to EOCR relays for Large Amp Motor Protection
■
1.0 Measuring Class
■
For EOCR Only
Specification
Model 3CT-100 3CT-150 3CT-200 3CT-300 3CT-400
Current Ratio 100 : 5A 150 : 5A 200 : 5A 300 : 5A 400 : 5A
Class 1.0 1.0 1.0 1.0 1.0
3CT Budden 5VA 5VA 5VA 5VA 5VA
Insulation Voltage 600VAC
Dielectric Strength 2kV
Insulation 10MΩ(500VDC Mugger)
Mounting Panel
ZCT
Zero Phase Current Transformer
Features
■
Applicable for Ground Fault Protection Devices (EGR)
■
Detect Zero Phase Current
■
For EOCR Only
Specification
Hole Dimension Type Hole
ZCT - 35 35mm
ZCT - 80 80mm
ZCT - 120 120mm
Primary GF Current 200mA
Secondary GF Current 1.5mA
Tolerance ±10%
Budden 10VA
ZCT
Rated Voltage 600VAC
Dielectric Strength 2kV
Insulation 10MΩ(500VAC Mugger)
Mounting Panel
www.junxele.com 17
JUNXELE Dimension
18 www.junxele.com
JUNXELE Dimension
www.junxele.com 19
JUNXELE LR97D/LT47
Electronic Over Current Relay
Presentation
LR97 D and LT47 electronic over current relays have been developed to satisfy machine protection requirements.
These relays have definite time characteristics: current threshold and time based function.
They are particularly recommended for providing mechanical protection on machines with high resistive torque, high
inertia and with strong probability of jamming under steady state conditions.
They can be used for motor protection in the case of long starting times or frequent starting.
The LR97 D relay also incorporates two fixed time protection functions, one of 0.5 seconds against locked rotor and
one of 3 seconds against phase failure.
LR97 D and LT47 can be used to provide mechanical shock protection. In this case, setting the O-Time knob to
minimum will ensure tripping in 0.3 seconds.
Applications
LR97D
LR97 D and LT47 relays are particularly suitable for the following machines:
■
Monitoring function for excessively long starting time on machines with a risk of difficult starting:
■
Machines with high resistive torque, high inertia machines.
■
Monitoring of machines during steady state operation: overtorque detection function
■
Machines with strong risk of jamming, machines with torque build-up over time,
■
Mechanical failure monitoring,
■
Faster detection of malfunctioning on machines where the motor is oversized in relation to its thermal protection I²t.
■
Motor protection for specific applications:
■
Machines with long starting times,
■
Machines with high on-load factor: more than 30 to 50 starts/hour,
■
Machine with fluctuating load from a steady state, where the thermal image of a thermal overload relay (thermal
memory) is unsuitable in relation to actual overheating of the motor.
Examples of machines:
■
Conveyors, crushers and mixers,
■
Fans, pumps and compressors,
LT47 ■
Centrifuges and spin-dryers,
■
Presses, shearing machines, saws, broaching machines, sanders and lifting hoists.
Description Operation
■ Because of their two separate time settings, LR97 D and LT47 relays can be combined with the motor-starter
LR97D
function:
■ D-Time: starting time, O-Time: trip time during steady state.
■ The D-Time function is only available during the motor starting phase. During this phase the overload detection
function is inhibited in order to allow starting. Under steady state conditions, when the motor current is greater than
the setting current due to an overload or single-phasing, the red LED lights up and the internal relay switches its
contact after a time preset by the O-Time knob.
■ The red LED stays on, indicating that the relay has tripped.
■ The relays are simple to set, in 5 easy steps:
■ Adjust the 3 knobs to maximum (Load, D-Time and O-Time),
■ Adjust the D-Time knob to the value corresponding to the motor starting time.
■ When the motor reaches steady state, adjust the Load knob (turn the knob counter-clockwise until the red LED
starts to flicker).
1 RESET knob
■ Slowly turn the Load knob clockwise until the LED goes out.
2 TEST/STOP knob
■ Set the required tripping time, using the O-Time knob.
3 Ready/Run Indicator
4 Relay tripped indicator Status Signaling
5 Current setting LR97D LT47
6 Adjustment of starting time
To assist fast diagnostics, two LEDs (one green and one red) allow Signaling of the operating status:
LT47
20 www.junxele.com
JUNXELE LR97D/LT47
Electronic Over Current Relay
www.junxele.com 21
JUNXELE LR97D/LT47
Electronic Over Current Relay
Operating Characteristics
Relay type LR97 D●●●●● LR97 D●●●S LR97 D●●●S
Adjustment Current A “Load” knob “Load” knob “Load” knob
Time D-time s 0.5…30 0.5…30 -
knob
O-time s 0.2/0.3…10 0.2/0.3…10 0.2/0.3…30
knob
R-time s - - 1…120
knob
Reset Manual Reset button Reset button Reset button
Automatic 120 sfixed - R-time knob: 1-120 s
Electrical By interruption of power By interruption of power By interruption of power
supply (minimum 0.1 s) supply (minimum 0.1 s) supply (minimum 0.1 s)
Tripping On starting Steady state On starting Steady state -
Protection functions
Inhibited After Inhibited After After O-time
Overload Imax > Isetting during during
D-time O-time D-time O-time
Locked rotor, mechanical Tripping After < 0.5 s Inhibited After After O-time
jamming I > 3 x Isetting D-time during O-time
D-time
Sensitivity to phase failure Tripping <3s <3s Inhibited After O-time After O-time
during
D-time
Status and fault Signaling (see table page 24517/2) 2 LEDs 2 LEDs 2 LEDs
TEST/STOP function Test No load No load No load
Stop Under load Under load Under load
Sealing Yes Yes Yes
22 www.junxele.com
JUNXELE LR97D/LT47
Electronic Over Current Relay
67,5 45
67,5 45
www.junxele.com 23
JUNXELE LR9F Series
Electronic Thermal Overload Relay
Presentation
LR9F electronic protection relays are especially suited to the operating conditions of motors.
They provide protection against:
■ thermal overload of 3-phase or single-phase balanced or unbalanced circuits;
■ phase failure and large phase unbalance,
■ protracted starting times,
■ prolonged stalled rotor condition.
LR9F electronic protection relays are mounted directly below an LC1 F type
contactor. They cover a range from 30 to 630 A, in eight ratings.
The settings can be locked by sealing the transparent protective cover.
A reset button is mounted on the front of the relay.
Two versions are available:
■ simplified version: class 10: LR9 F●3●●, class 20: LR9 F●5●●.
■ conplete version: class 10, 10A or class 20, selectable, conforming to EN 60947-4-1: LR9 F●●.
This latter version includes an alarm function which makes it possible to forestall tripping by load shedding.
1.radjustment dial
2.Test button
3.Stop button
4.Reset button
5.Trip indicator
6.Setting locked by sealing the cover
“Stop” function 3
Stop
“Test” function 2
Test
Trip indicator
24 www.junxele.com
JUNXELE LR9F Series
Electronic Thermal Overload Relay
Thermal overload relays:
■ Compensated and differential,
■ With relay trip indicator,
■ For a.c.,
LR9 F5367
LR9 F7375
LA7 F902
www.junxele.com 25
JUNXELE LR9F Series
Electronic Thermal Overload Relay
Relay type LR9 F5●57, F57 F5●63, F63 F5●71, F71 F7●75, F75 F7●81, F81
F5●67, F67 F7●79, F79
F5●69, F69
26 www.junxele.com
JUNXELE LR9F Series
Electronic Thermal Overload Relay
Common side view LR9 F5●71, F71 LR9 F5●57, F5●63, F5●67,
LR9 F5●69, F57, F63, F67, F69
(1)Terminal shroud LA9 F70● (2) 6.5 x 13.5 for LR9 F5●57 and F57. 8.5 x 13.5 for LR9 F5●63, F5●67, F5●69, F63, F67, F69
Common side view LR9 F7●75, F7●79, F7●81, LR9 F7●81 (for mounting beneath LC1 F630 and F800),
LR9 F75, F79, F81 LR9 F81
(1)Terminal shroud
LA9 F70●
P1 P2
LR9 F7●75, F75 48 48
LR9 F7●79, F7●81, F79, F81 55 55
www.junxele.com 27
JUNXELE GMP Series
Electronic Overload Relay
Ratings
Stall ● ● ● ● ● ● ●
Asymmetry _ _ ● _ ● _ ●
28 www.junxele.com
JUNXELE GMP Series
Electronic Overload Relay
Ratings
Phase failure ● ● ● ● ● ● ● ●
Stall ● ● ● ● ● ● ● ●
Asymmetry _ ● _ ● _ ● _ ●
Direct/Separate mount
Mounting type Direct mount onto a MC Separate mount(Screw or Din-rail)
(Screw or Din-rail )
GMC-50, GMC-65,
Applied MC GMC-32, GMC-40
GMC-75, GMC-85
www.junxele.com 29
JUNXELE GMP Series
Electronic Overload Relay
Description
■ Wide and adjustable current range
■ Adjustable trip time (trip class 5-10-15-20-30)
■ Designed suitable for use with contactors
Directly mountable on the GM-9, 12, 18, 22 contactors Separate mount versions are also available Separately
mountable on 35mm DIN rail or with screws
■ 1NO+1NC trip contacts
■ Manual reset as standard (Automatic reset optional)
GMP22-3P
Extended Protective Functions
Selection
30 www.junxele.com
JUNXELE GMP Series
Electronic Overload Relay
Description
■ Wide and adjustable current range
■ Adjustable trip time (trip class 5-10-15-20-30)
■ Designed suitable for use with contactors
Selection
www.junxele.com 31
JUNXELE GMP Series
Electronic Overload Relay
Description
■ Wide and adjustable current range
■ Adjustable trip time (trip class 5-10-15-20-30)
■ Designed suitable for use with contactors GM-50, 65, 75, 85
Separately mountable on 35mm DIN rail or with screws
■ 1NO+1NC trip contacts
■ Manual reset as standard (Automatic reset optional)
■ Extended protective functions
Selection
Technical Information
32 www.junxele.com
JUNXELE GMP Series
Electronic Overload Relays
Description
■ Small size, economical ■ Definite time characteristics
■ Delay time setting in starting and operation ■ Wide current setting range
■ Over current, phase failure protection ■ Screw or Din-rail mounting
Model GMP60T
Type Tunnel type
No. of CT 2
0.5~6
Current setting
3~30
range(A)
5~60
Operating time characteristics Definite time characteristics
Starting time 0.2~30
Time setting
Operating time 0.2~15
(sec.)
Reset time Manual reset
Allowable Current ±5%
error Time ±5%(or ±0.5 sec.)
Voltage 180~260V (110V / 440V) Note2
Control power
Frequency 50/ 60Hz
Contact 1SPDT(1c)
Contact configuration Aux.
Ratings 5A 250Vac, resistive load
s/w
Operation 95┤├96close
Insulation resistance Min. 50�at 500Vdc
Surge insurance(IEC 1000-4-5) 7kV(6times for 1min. Interval)
Fast transient burst(IEC 1000-4-4) 2.5kV/5min
Environment Operation -25~70℃
Temperature Storage -50~80℃
Relative humidity 46~85 RH(No freezing)
Trip indicator LED
Dimension(mm) W× ×H× ×D 72×63×69
Mounting type Separate mount(Screw & Din-rail)
Applied MC GMC-9, 12, 18, 32, 40, 50
Ordering Information
Specify catalog number
www.junxele.com 33
JUNXELE GMP Series
Electronic Overload Relay
DCT( Current transformer)
Ratings
Number of sensors
2CT
Types (GMP80-□)
DCT-100 100 : 5A
DCT-150 150 : 5A
CT ratio
DCT-200 200 : 5A
DCT-300 300 : 5A
DCT-400 400 : 5A
Class 1.0
Burden 5VA
Insulation voltage 600VAC
Insulated impulse voltage 2kV
Insulation resistance 10MΩ(DC 500V Mugger)
Mounting Panel
Note: Please use DCT for LG Electronic Motor Protection Relay only.
Dimension
34 www.junxele.com
JUNXELE GMP Series
Electronic Overload Relay
GMP22-2P
GMP22-3P
GMP22-3PR
GMP40-2P
GMP40-3P
GMP40-3PR
GMP22-2S
GMP22-3S
GMP22-3SR
GMP40-2S
GMP40-3S
GMP40-3SR
GMP22-2T
GMP22-3T
GMP22-3TR
GMP40-2T
GMP40-3T
GMP40-3TR
www.junxele.com 35
JUNXELE GMP Series
Electronic Overload Relay
GMP80-2S
GMP80-3S
GMP80-3SR
GMP80-2S
Terminal Configuration
Circuit Diagram
36 www.junxele.com
JUNXELE GMP Series
Electronic Overload Relay
GMP 60T
GMP60T
Circuit Diagram
Terminal Configuration
www.junxele.com 37
JUNXELE 3RB20 Series
Electronic Overload Relay
3RB20 for Standard Applications
3RB20 overload relays with screw connection on auxiliary current side for direct mounting1)2) and stand-alone
installation2)3), CLASS 10
Features and technical specifications:
■
Overload protection, phase failure protection and unbalance protection
■
Internal power supply
■
Auxiliary contacts 1 NO + 1 NC
■
Manual and automatic RESET
■
Switch position indicator
■
TEST function and self-monitoring
S00 0.04 … 0.09 0.1 … 0.4 2 3RB20 6-1RB0 1 1 unit 101 0.200
▲
3RB20 16-1RB0
3RB20 26-1QB0
3RB20 36-1UB0
38 www.junxele.com
JUNXELE 3RB20 Series
Electronic Overload Relay
Extended protective functions
Size Rating for Set current Short-circuit DT Order Price PU PS* PG Weight
Con- induction value protection No. per PU (UNIT, per PU
tactor motor of the with fuse, SET, M) approx.
4) Rated inverse- type of
value5) time delayed coordination
overload trip 2, gL/gG
operational
class6)
kW A A
▲
11 … 45 25 … 100 200 3RB20 46-1EB0 1 1 unit 101 0.560
▲
1…4 1 1 unit 101 0.450
3RB20 46-1EB0
3RB20 56-1FW2
and size 90 … 450 160 … 630 800 3RB20 66-1MC2 1 1 unit 101 1.820
▲
14
(3TF68/
3TF69)
3RB20 66-1MC2
1) The relays with an Order No. ending with “0” are designed for direct mounting. With the matching
terminal brackets (see Accessories) the sizes S00 and S0 can also be installed as stand-alone units.
2) The relays with an Order No. ending with “2” are designed for direct mounting and stand-alone
installation. For 3TF68/3TF69 contactors, direct mounting is not possible.
3) The relays with an Order No. ending with “1” are designed for stand-aloneinstallation.
4) Observe maximum rated operational current of the devices.
5) Standard value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
6) Maximum fuse for overload relay, type of coordination 2. For fuse values in conjunction with contactors, see
Technical Specifications, Short-Circuit Protection with Fuses for Motor Feeders.
7) The relays with an Order No. with “W” in penultimate position are equipped with a straight-through
transformer.
www.junxele.com 39
JUNXELE RST 25
Electronic Voltage Relay
Operation Instructions
The electronic phase relay RST 25 offers phase, philure shift, phase flashing, asymmetric, Phase sequence and
also under and overvoltage control.
Connection
Undervoltage
The desired undervoltage limit can be adjusted down to-25% UN.
Asymmetry
The adjusting over-and undervoltage limit, the asymmetric limit is slso adjusted.
Time Delay
The switch off time can be adjusted by the potentiometer “Time Delay” from 0.1……5 seconds. With this
function it is possible to adjust the time for the identification of the failure.
Contactor Control
If a phase fails during operation at load or one of the contacts of the contactor or circuit Breaker is
defective,(contact bounce or scorched contacts), RST 25 recognizes the failure, And also the feedback voltage,
and switches off depending on the setting of “Time Delay”. The RST 25 controls the phase shift. If there is a
phase failure the angle from the feedback Voltage is 30°. The RST 25 recognizes this failure.
40 www.junxele.com
JUNXELE RST 25
Electronic Overload Relay
Technical Data
Housing as per VDE 0304, fixed by means of snap in lock on caprail(DIN 50022-35). Non-Inflammable,
resistant to temperatures up to 150°C. Air-gap and leak resistance according Go VDE 0100. DIN 57110,
C500 VE/600 VG. Material of terminals CuSN6 gold. Cross-section of connecting Lead 2χ2.5mm2. protection
against electrical shock, M4-screws.
www.junxele.com 41