Electronic Over Current Relays

Electronic Over Current Relay / Electronic Voltage Relays


Other Protection & Monitoring Devices / Current Transformers

www.junxele.com
CONTENT
2 EOCR-SS Electronic Overload Relay
3 EOCR-SP1/SP2 Electronic Overload Relay
3 EOCR-SP40 Electronic Overload Relay
4 EOCR-DS Electronic Overload Relay
5 EOCR-SSD Digtal Over-current Relay
6 EOCR-3DE/3EZ Digtal Over-current Relay
9 EOCR-3DM/3MS/3MZ Digtal Over-current Relay
12 EVR Electronic AC Voltage Relay
12 EVR-PD Digtal AC Voltage Relay
13 EGR Electronic Ground Fault Relay
13 PMR-44 Electronic Phase Monitoring Relay
14 EOCR-1P Single Phase Relay
15 EOCR-DZ(T) Electronic Ground Fault Relay
16 DCL/DUCR Electronic DC Current Relay
16 DOVR/DUVR Electronic DC Voltage Relay
17 2CT Current Transformer
17 3CT Current Transformer
17 ZCT Current Transformer
18 Dimension
20 LR97D/LT47 Electronic Over Current Relay
24 LR9F Electronic Thermal Overload Relay
28 GMP Electronic Overload Relay
38 3RB20 Electronic Overload Relay
40 RST25 Electronic Overload Relay

www.junxele.com
JUNXELE EOCR-SS
Electronic Overload Relay

Features Wide Adjustment Range


■ Compact Design EOCR has a wide current adjustment range of over
■ Multiple Protection Functions 10:1. It enables three type models to cover a wide
■ Wide Current Adjustment Range (10:1) range from 0.1A up to 600A thus reducing the
■ Ammeter Function number and type of relays that must be inventoried
for spare purposes.
■ Trip Indication LED
■ High Accuracy Looping Option
■ Manual Instantaneous Reset
■ Electrical Remote Reset Some motor size may require only one-third or
one-fourth of particular EOCR current range. These
■ Test Function
installations can be accommodated by looping the
■ Ambient Insensitive motor wire 2 or 3 times through the integral current
EOCR-SS ■ Low Energy Consumption transformers of the EOCR. This reduces the number
■ Fail-safe Operation (No Volt Release) and type of relays inventoried for spare purposes.
Each additional loop will increase the current

2 Integral Current Transformers Over-Current Protection measured as indicated by the following chart.

Electronic Shear-pin Function No. of Time of Current Set.
Over-current protection is provided by tripping the

Independently Adjustable Starting Trip Delay Loops Passing Range(A)
relay when motor operating current (In) exceeds
(D-Time) & Operating Time (O-TIME) 05Type 0 1 0.50 - 6.0A
over-current setting (Is) of EOCR for a period greater 1 2 0.25 - 3.0A
than the preset operating time (O-Time). Looping 2 3 0.17 - 2.0A
Option 3 4 0.12 - 1.5A
Protection 4 5 0.10 - 1.2A
Protective Item Operating (Trip) Time
Over-current O-TIME
Phase Loss O-TIME
Locked Rotor O-TIME + D-TIME

Specification
Current setting Type Range Phase Loss Protection Straight-through-Wiring Looping Option(1-Loop)
05 0.5 - 6A
30 3 - 30A During a phase loss, the motor winding current may External Current Transformer Option
60 5 - 60A increase by 150% or more.
100~(over 60A) Ext. CT Option As the motor winding current increases, the winding Ordering option - 05 type of each model fitted to
Time Start D-TIME 0.2 - 30 sec temperature may also increase and possibly damage an external current transformer can achieve higher
Setting Trip O-TIME 0.2 - 10 sec the winding insulation. ampere ranges. (Ext. CT Option)
Control Voltage 220 90 - 260VAC The quick trip time on EOCR helps to prevent over- Type Current Ratio Current Setting
(50/60Hz) 440 320 - 480VAC current damage to the windings. of Ext. CT Range
Output Relay Mode 1-SPDT(1C) 05 - 0.5 - 6A
Rating 3A/250VAC Resistive 100 100:5 10 - 120A
Ext. CT 200 200:5 20 - 240A
Status Normally Energized 300 300:5 30 - 360A
Option
Time-Current Characteristic Definite 400 400:5 40 - 480A
Operating (Trip) Indication 2-LED 500 500:5 50 - 600A
Mount 35mm Din-rail / Panel 600 600:5 60 - 720A

Typical Wiring ss

Ammeter Function & Trip Indication


Indication LED on the dial plate provides trip
indication and ammeter functions.
External CT Option
The LED starts to flash at the point where motor
current is equal to current setting level (Is), so Manual Instantaneous Reset
user can verify motor current by reading the LOAD
adjustment scale on the dial plate. Pushing RESET button on the dial plate or
This also provides an accurate current setting. interrupting power supply provides a manual
instantaneous reset.
The LED is illuminated when motor current exceeds
Electrical remote reset is also provided by the panel-
current setting (Overload Status). mounted RESET button.
After tripping has occurred, the LED stays on until
the relay is reset. Low Energy Consumption
The trip indication is also an important feature of a EOCR-SS uses only 250mA of power, much less
multiple relay & contactor (starter) installation. than thermal bimetallic overload relays. The result is
significant cost savings over the life of relays (over
20 times cost saving).

2 www.junxele.com
JUNXELE EOCR-SP1 / SP2
Electronic Overload Relay


2 Integral Current Transformers

Fits Directly into IEC or NEMA Contactor

Protection
EOCR Operating (Trip) Time
Protective Item
SP1 SP2
Over-current O-TIME(curve) 5sec
Phase Loss 4sec 4sec
EOCR-SP1/SP2 Locked Rotor O-TIME+10sec D-TIME
Time Characteristic Inverse Definite

Typical Wiring
Specification
EOCR SP1 SP2
Current Setting 01 0.3 - 1.2A 03 - 1.2A
10 1 - 12A 1 - 12A
20 5 - 25A 5 - 25A
Time Start D-TIME 10 sec(Fixed) 1 - 50 sec
Setting Trip O-TIME 1 - 10 5 sec(Fixed)
Control Voltage 110 85 - 150VAC
(50/60Hz) 220 180 - 260VAC
Mode 2-SPST
Output Relay Rating 3A/250VAC Resistive
Status Normally Energized
Time-Current Characteristic Inverse Definite
Trip & Trip Cause Indication 2-LED
Mount Contactor Mounted

EOCR-SP40
Electronic Overload Relay


3 Integral Current Transformers

Electrcnic Shear-pin Function

Independently Adjustable Staring Trip Delay(D-Time)&Trip Time(O-Time)

Fits Directly into IEC or NEMA Contactor

Protection
EOCR-SP40 Protective Item Operating (Trip) Time
Over-current O-TIME
Phase Loss O-TIME
Locked Rotor O-TIME + D-TIME

Typical Wiring Specification


Current Setting Type Range
40 8-40A
30 0.5 - 30 sec
60 0.5 - 10 sec
Time Start D-TIME 0.2 - 30 sec
Setting Trip O-TIME 0.2 - 10 sec
Control Voltage 220 90 - 260VAC
(50/60Hz) 440 320 - 480VAC
Output Relay Mode 2-SPST
Rating 3A/250VAC Resistive
Status Normally Energized
Time-Current Characteristic Definite
Operating (Trip) Indication 2-LED
Mount 35mm Din-rail / Panel

www.junxele.com 3
JUNXELE EOCR-DS/DST
Electronic Overload Relay

■ 3 Integral Current Transformers


■ Electrcnic Shear-pin Function
■ Independently Adjustable Staring Trip Delay(D-Time)&Trip Time(O-Time)
■ EOCR-DS + Power Terminal Kit → EOCR-DST

Protection
Protective Item Operating (Trip) Time
Over-current O-TIME
EOCR-DS EOCR-DST Phase Loss O-TIME
Locked Rotor O-TIME + D-TIME

Typical Wiring Specification


Current Setting Type Range
05 0.5 - 6A
30 3 - 30A
60 5 - 60A
100~ (over 60A) Ext. CT Option
Time Start D-TIME 0.2 - 30 sec
Setting Trip O-TIME 0.2 - 10 sec
Control Voltage 220 90 - 260VAC
(50/60Hz) 440 320 - 480VAC
Output Relay Mode 2-SPST
Rating 3A/250VAC Resistive
D 1,2,3 Status Normally Energized
Time-Current Characteristic Definite
Operating (Trip) Indication 2-LED
Mount 35mm Din-rail / Panel

EOCR-DS1 / DS2 / DS3


Electronic Overload Relay
■ 3 Integral Current Transformers
■ Independently Adjustable Starting Trip Delay & Trip Time
■ EOCR-DS1/2/3 + Power Terminal Kit = EOCR-DS1T/2T/3T
Protection
Protective Item EOCR Operating (Trip) Time
DS1(T) DS2(T) DS3(T)
Over-current O-TIME(curve) O-TIME O-TIME
Phase Loss 4sec 4sec 4sec
EOCR-DS1/DS2/DS3
Locked Rotor D-TIME D-TIME D-TIME
Phase Reversal - - 0.1sec
Typical Wiring Time Characteristic Inverse Definite Definite
Specification
EOCR Type DS1(T) DS2(T) DS3(T)
Current Setting 05 0.5-6A 0.5-6A 0.5-6A
30 3-30A 3-30A 3-30A
60 - 5-60A 5-60A
100~ (over 60A) External CT Option
Time Start D-TIME 0-50 sec 1-50 sec
Setting Trip O-TIME 1-10 0.2-10 sec
Control Voltage 110 85-150VAC
(50/60Hz) 220 180-260VAC
Mode 2-SPST
Output Relay
Rating 3A/250VAC Resistive
Status Normally Energized
Time-Current Characteristic Inverse Definite Definite
Trip&Trip Cause Indication 2-LED
Mount 35mm Din-rail

4 www.junxele.com
JUNXELE EOCR-SSD
Digital Over-Current Relay

Protection

Protective Item Trip Time Description


Over-current O-Time Is<In
Phase Loss 3sec [(MAX - MIN) / MAX] × 100>90
Locked Rotor 0.5sec after elapse dt ≥3times OC setting value

Specification

Over-current Setting Current 05 0.5 ~ 6A


EOCR-SSD 30 3 ~ 30A
60 10 ~ 60A
Starting delay time D-Time 1 ~ 30sec
Trip time O-Time 0.5, 1 ~ 10sec
Reset Manual / Electrical
Operating t-c characteristic Over-current Definite
Tolerance Current I<1A : ± 0.05A, I 1A : ±5%
Time t 3S : ± 0.2s, t>3s : ±5%
Environment Temperature Operation -20℃~60℃
Store -30℃~80℃
Humidity 30~85% RH non-condensing
Control Power ·110 : 110VAC±15%, 50/60Hz
·220 : 220VAC±15%, 50/60Hz
·440 : 440VAC±15%, 50/60Hz
·24 : 240VAC/DC
Output relay 2-SPST 3A / 250VAC , Resistive
Insulation Between casing and circuit Over 10M�, DC500V
Dielectric Strength Between casing and circuit 2000VAC 60Hz, 1min
Between open contacts 1000VAC 60Hz, 1min
Between circuit 2000VAC 60Hz, 1min
Installation 35mm Din Rail or Panel Mounting


MCU(Micro Controller Unit) based / 2-CT Type

Real Time Processing / Higher Precision

Current Setting Range - 05Type : 0.5 ~ 6A / 30Type : 3 ~ 30A / 60Type : 10 ~ 60A

Digital display : trip cause / easy troubleshooting

Reset : Manual (instantaneous) / Electrical (remote)

Load selection by DIP switch : Single phase(1P) / Three phase(3P)

Fail safe(N) / Non-fail safe(R)

www.junxele.com 5
JUNXELE EOCR-3DE/3EZ
Digital Over-Current Relay

MCU Based

3 Integral Current Transformers

Over-current, Under-Current, Phase Loss, Phase
Unbalance, Phase Reversal, Locked Rotor Protection

Digital Ammeter & Trip cause indication

Selectable Trip Time-Current Characteristics

Independently Adjustable Starting Trip Delay and Operating

Trip Time
+ Load Alerting Function → EOCR-3DE
+ Ground Fault Protection → EOCR-3EZ

Protection
EOCR-3DE/3EZ EOCR-3DE EOCR-3EZ
Protective Item Trip Time Protective Item Trip Time
Over-current O-TIME Over-current O-TIME
Typical Wiring under-current 0.5~30sec Under-current 0.5~30sec
Phase Loss 3 sec Phase Loss 3 sec
Phase Unbalance 8 sec Phase Unbalance 8 sec
Phase Reversal 0.1~0.3 sec Phase Reversal 0.1~0.3 sec
Locked Rotor D-TIME Locked Rotor D-TIME
- - Ground Fault 0.05~10 sec

Specification
Model EOCR-3DE EOCR-3EZ
Over Current Setting Range Refer Table #1
Ground Fault Current Setting - 0.02 ~ 3A
Alert Setting 50 ~ 100% / OFF -
Start Delay Time Setting (D-TIME) 1 ~ 200 Sec
Trip Delay Time Setting (O-TIME) INV 1 ~ 30
DEF 0.2 ~ 30 Sec
Control Voltage 24VAC/DC, 110VAC±15%, 220VAC±15%
Output Relay OL 2-SPST 1-SPST
AL/GR AL Relay Ground Fault Relay
Rating 3A/250VAC Resistive
Time Characteristic In/”tc”mode Inverse (See Curve-1)
EOCR-3DE dE/”tc”mode Definite (See Curve-2)
Troubleshooting / Trip Indication LED Display (SSD+LED)
Current Sensing 3-CT
Mounting 35mm Din-rail

Table #1. Current Range


Current Setting Number of Conductors
Extermal CT Ratio Setting of CT Ratio Remark
Range (Amps) thru CT windows
0.5 ~ 60A 1 - OFF(Mode : --) Wide Range
0.25 ~ 3.0A 2 - 2t
0.1 ~ 1.2A 5 - 5t
1 ~ 12A 1 10 : 5 10
1.5 ~ 18A 1 15 : 5 15
2.0 ~ 24A 1 20 : 5 20
2.5 ~ 30A 1 25 : 5 25
3.0 ~ 36A 1 30 : 5 30
4.0 ~ 48A 1 40 : 5 40
EOCR-3EZ 5 ~ 60A 1 50 : 5 50
※Tolerance(3DD/ 3DZ / FD / FDZ / PMZ / SSD) 6 ~ 72A 1 60 : 5 60
7.5 ~ 90A 1 75 : 5 75
I<1A : ±0.05A 10 ~ 120A 1 100 : 5 100
Current
I≥1A : ±5% 12 ~ 144A 1 120 : 5 120
0.05s → Within 0.05s 15 ~ 180A 1 150 : 5 150
20 ~ 240A 1 200 : 5 200
Time t≤3s : ±0.2S 25 ~ 300A 1 250 : 5 250
t>3s : ±5% 30 ~ 360A 1 300 : 5 300
Caution 40 ~ 480A 1 400 : 5 400
50 ~ 600A 1 500 : 5 500
The external CT should be used in case Inverse
60 ~ 720A 1 600 : 5 600
curve(toln setting) is applied over 10Amps.
75 ~ 900A 1 750 : 5 750
80 ~ 960A 1 800 : 5 800

6 www.junxele.com
JUNXELE EOCR-3DE/3EZ Series
Digital Over-Current Relay

Features Looping Option


■ Compact Design Smaller ampere ranges than particular EOCR current range can be covered
■ 3DE/3EZ : Panel Mounting Type by looping the motor wire 2 or 3 times as under described.
■ MCU(Microprocessor Control Unit) Based No. of Current Ratio Current Set.
■ 3 Integral Current Transformers Loops of Ext.CT Range(A)
■ Multiple Protection Functions 05Type 0 1 0.50 - 6.0A
■ Digital Ammeter 1 2 0.25 - 3.0A
Looping 2 3 0.17 - 2.0A
■ Troubleshooting / Trip Cause Memory, Display
Option 3 4 0.12 - 1.5A
■ Adjustable Operating Features by Mode switch
4 5 0.10 - 1.2A Looping Option(1-Loop)
■ Wide Current Adjustment Range
■ Selectable Time-Current Characteristics (Inverse / Definite) External CT Option
■ Manual (Instantaneous) / Electrical (Remote) Reset Higher ampere ranges can be achieved by setting in “CT” mode fitted to an
■ Test Function external current transformer, and the actual motor current display is possible
■ Ambient Insensitive in any case
■ Selectable Fail-safe and Non-fail-safe Operation Modes Value in Current Setting
Type “CT” mode Range (A)
Comparison Table of Model wide Range OFF(--) 0.5 ~ 60A
10 : 5 10 1 ~ 12A
EOCR 3DE 3EZ 15 : 5 15 1.5 ~ 18A
Protection Over - current


● ●
Under - current ● ● 800 : 5 800 80 ~ 960A
Phase Loss ● ●
EOCR-3DE+Extemal CT
Phase Unbalance ● ● Alert Function
Phase Reverse ● ● When motor operating current (In) exceeds the alert setting (As), the alertrelay
Locked Rotor ● ● outputs three kind of signal. The output can be used to warn customers/
Ground Fault - ● operators of possible overloading and avoid unnecessary motor shutdown.
Run Monitor & Load Alert Function ● - The type of output signal is decided by the selection in the “Alo” mode
Selectable Alerting Pulse ● - “A”(Ampere relay): energized whenever CT senses a current
“F”(Flickering): character“A” and current value flashs frequently
Protection Feature “H”(Holding): ON-OFF
“U”(Undercurrent mode): the “AL” output(07┫┣08) is transferred into
Function Mode Description “Uc” output
dE This is provided by the relay tripping when motor operating
current(In) exceeds current setting value in “oc” mode for a
Running state More then
(Definite Normal preset(%) of Alert Trip
period greater than the preset trip time(O-Time in “ot” mode) Setting“ALo”
T-C) (Curve-2)
Over-
tc Flicker“F”

current In This is provided by the relay tripping when motor operating
(Inverse current(In) exceeds current setting value in “oc” mode
T-C) according to the Time-current Characteristic Curve(Curve-1) Hole“H” 2sec
This is provided by the relay tripping when motor operating
Under- Definite current(In) is lower than current setting value in “uc” mode Aux“A”
Uc
current T-C for a perid greater than the preset trip time(Time in “ut”
mode) In = Motor Operating Current / Is = EOCR Over-current Setting / As = Alert
Phase The relay will be operated within 3sec. When the phase failure Setting
PL On
Loss occurs
Fail-safe & Non-fail-safe
This is provided by the relay tripping in phase unbalance
Phase greater than setting % difference in terms of maximum phase The tripping relay can be operated in a fail-safe or non-fail-safe mode
Ub 5~50%
Unbalance current : [(MAX-MIN)/MAX]×100[%]
On In the event of phase reversal, the relay trips in 0.1sec Application of the Fail-safe (Electrically Held) Connection
Phase RP Phase reversal protection function is disabled : this allows the
Reversal Off(--) Faye safe setting in“FS” mode : ON
relay to be used for reversing application
The tripping relay is normally energized with control power supply
Ground Ground fault protection is provided by the relay tripping
Fault Ec 0.03~3A accoding to zero sequence current sensed by ZCT Application of the Non-fail-safe Connection
This is a protection for locked rotor in starting state.The variable
2~10 setting range is 2~10 times oc setting value, but maximum
Fail safe setting in “FS” mode: OFF(--)
Locked In all cases, the failure of the control voltage may not interrupt the process.
Lc Times setting value is limited in case“oc” setting value is greater
Rotor
than 10A. The maximum setting value is calculated by [100/oc
OC
setting value]

This is a protection for locked rotor while motor is working. The


1.5~5 variable setting range is 1.5~5 times oc setting value, but the
Stall Sc Times maximum setting value is limited in case “oc” setting value
OC is greater than 20A The maximun setting value is calculated by
[100/oc seting value]

※T-C : Time-Current Characteristic

www.junxele.com 7
JUNXELE EOCR-3DE/3EZ
Digital Over-Current Relay

LED Display Examples of Trip Cause Indication

■ Over-current Trip
Relay displays a trip, caused by over-current.
which has been detected from phase L1(R/T1).
■ Under-current Trip
Relay displays a trip, caused by under-current.
Digital Ammeter which has been detected from phase L2(S/T2).
3 phase motor currents (In) / Ground fault current are displayed in ■ Phase Loss Trip
sequence on the LED display. Relay displays a trip, caused by phase loss
■ 3DE (Phase Failure) on Phase L2(S/T2)

■ Phase Reversal Trip


Relay displays a trip, caused by phase reversal.

■ Phase Unbalance Trip


Relay displays a trip, caused by phase
unbalance. in phase L1(R/T1).
■ Ground fault Trip : EOCR-3DZ/FDZ Only
Relay displays a trip, caused by ground
fault current
■ 3EZ ■ Locked Rotor Trip
Relay displays a trip, caused by locked rotor.
during starting state
■ Locked Rotor Trip
Relay displays a trip, caused by locked rotor.
while motor is working

Time-Current Characteristic Curve

Rotation display of Phase current


Instead of automatic rotation, manual display rotation is possible as
depressing once SET/Store button during an operation. If manual is selected,
the information of phase current L1 is displayed firstly and next information
is displayed continuously like a manner of →L1→L2 →L3→(GR)→L1 …
O-T Setting IEC 947-4
whenever depress SET/Strore button evey once (Curve) (Trip Class)
Digital Trip Cause Indication / Easy Troubleshooting 1-5 10A

- Enter into “trip” mode by depressing once Set/store button, then last trip 6-10 10
cause is showed 11-20 20
- Each phase current is displayed in order whenever depress UP/DN button in 21-30 30
every once under trip mode
- The 2nd trip cause is showed after displaying 3phase current of last trip
- The 3rd trip can be checked by same manner
Test
This is the self-test of this product. If the relay enters into this mode, it begins
to count down preset value of O-time after wating 3sec and becomes trip state
as showing “END” message that means this relay is ready to work.
- “END” message of this test is also stored in “Fault” mode as last trip.
- Not permitted to test this function during the operation to prevent
unnecessary trip
Reset
Depressing the RESET button or interrupting control power resets the relay
immediately. Electrical remote reset is also available through the panel
mounted reset switch.

8 www.junxele.com
JUNXELE EOCR-3DM/3MS/3MZ
Digital Over-Current Relay

Over-current, Under-current, Phase Loss,
Phase reversal,Phase Unbalance, Locked rotor
protection

Short current protection ← 3MS

Ground Fault Protection ← 3MZ

Including Current Transducer : 4~20mA output

Accumulation to Running time

EOCR-3DM
Protection
Trip Time
Protective Item 3DM 3MS 3MZ
Over-current DEF: 0.2 ~ 30sec, INV: 1 ~ 30 DEF: 0.2 ~ 30sec, INV: 1 ~ 30 DEF: 0.2 ~ 30sec, INV: 1 ~ 30
Under-Current 0.5 ~ 30sec(DEF) 0.5 ~ 30sec(DEF) 0.5 ~ 30sec(DEF)
Phase loss 3sec 3sec 3sec
Phase reversal 0.1sec 0.1sec 0.1sec
Phase Unbalance 8sec 8sec 8sec
Locked Roter Lock 0.5sec after dt 0.5sec after dt 0.5sec after dt
Stall 1 ~ 10sec 1 ~ 10sec 1 ~ 10sec
Ground fault - - 0.1 ~ 10sec

Specification
Model 3DM 3MS 3MZ
Current Setting Over-Current(oc) Refer to, Table #1 Refer to, Table #1 Refer to, Table #1
Range Under-Current(uc) 0.5 ~ under OC setting 0.5 ~ under OC setting 0.5 ~ under OC setting
Ground Fault Current(Ec) - - A : 0.03 ~ 2.5A / B : 0.5 ~ 10A
Time Setting Starting Delay Time(dt) OFF ~ 200sec OFF ~ 200sec OFF ~ 200sec
Over-Current Trip Delay(ot) DEF : 0.2 ~ 30sec / INV : 1 ~ 30 DEF : 0.2 ~ 30sec / INV : 1 ~ 30 DEF : 0.2 ~ 30sec / INV : 1 ~ 30
Under-Current Trip Delay(ut) 0.5 ~ 30sec(DEF) 0.5 ~ 30sec(DEF) 0.5 ~ 30sec(DEF)
Ground Fault Trip Delay(Et) - - 0.1 ~ 10sec
Control Power 220 85 ~ 250VAC/DC, 50/60Hz 85 ~ 250VAC/DC, 50/60Hz 85 ~ 250VAC/DC, 50/60Hz
Output Relay OL 2-SPST, 3A/250VAC, Resistive 2-SPST, 3A/250VAC, Resistive 1-SPST, 3A/250VAC, Resistive
AL(GR/SC) 1-SPST(AL) 1-SPST(S.C) 1-SPST(GR)
Environment Temperature Store -30℃ ~ 80℃ -30℃ ~ 80℃ -30℃ ~ 80℃
Operation -20℃ ~ 60℃ -20℃ ~ 60℃ -20℃ ~ 60℃
Humidity 30 ~ 85RH, Without condensation 30 ~ 85RH, Without condensation 30 ~ 85RH, Without condensation
Display 7-Segment LEDs ○ ○ ○
Bar-Graph ○ ○ ○
Mounting 35mm Din-rail 35mm Din-rail 35mm Din-rail

Table #1. Current Range


Type Current Setting range Number of Conductor Position of DIP S/W4 External CT ratio Setting of CT Mode
thru CT windows Remark
05 0.1 ~ 2.0A 5 05 NIL 5t
05 0.25 ~ 5.0A 2 05 NIL 5t
05 0.5 ~ 10A 1 05 NIL 05
※60 5 ~ 70A 1 60 NIL 60
※※20 5 ~ 20A 1 20 NIL 20
10 1.0 ~ 12A 1 05 10 : 5 10
15 1.5 ~ 18A 1 05 15 : 5 15
20 2.0 ~ 24A 1 05 20 : 5 20
25 2.5 ~ 30A 1 05 25 : 5 25
30 3.0 ~ 36A 1 05 30 : 5 30
40 4.0 ~ 48A 1 05 40 : 5 40
50 5.0 ~ 60A 1 05 50 : 5 50
60 6.0 ~ 72A 1 05 60 : 5 60
75 7.5 ~ 90A 1 05 75 : 5 75
100 10 ~ 120A 1 05 100 : 5 100
120 12 ~ 144A 1 05 120 : 5 120
150 15 ~ 180A 1 05 150 : 5 150
200 20 ~ 240A 1 05 200 : 5 200
250 25 ~ 300A 1 05 250 : 5 250
300 30 ~ 360A 1 05 300 : 5 300
400 40 ~ 480A 1 05 400 : 5 400
500 50 ~ 600A 1 05 500 : 5 500
600 60 ~ 720A 1 05 600 : 5 600
750 75 ~ 900A 1 05 750 : 5 750
800 80 ~ 960A 1 05 800 : 5 800
*EOCR-3DM, 3MZ **EOCR-3MS

www.junxele.com 9
JUNXELE EOCR-3DM/3MS/3MZ
Digital Over Current Relay

Features Looping & External CT Option


■ Compact Design Refer to page 10
■ 3DM : Panel Mounting Type
■ MCU(Microprocessor Control Unit) & ASIC Based Alert Function : 3DM
■ 3 Integral Current Transformers When motor operating current (In) exceeds the alert setting (As), the alert
■ Multiple Protection Functions relay outputs three kind of signal. The output can be used to warn customers/
■ Digital Ammeter operators
■ Troubleshooting / Trip Cause Memory, Display of possible overloading and avoid unnecessary motor shutdown.
■ Adjustable Operating Features by Pulse Rotary switch The type of output signal is decided by the selection in the “Alo” mode
■ Wide Current Adjustment Range “A”(Ampere relay): energized whenever CT senses a current
■ Selectable Time-Current Characteristics (Inverse / Definite) “F”(Flickering): character“A” and current value flash frequently
■ Manual Instantaneous / Electrical Remote Auto Reset “H”(Holding): ON-OFF
■ Test Function
■ Ambient Insensitive
■ Selectable Fail-safe and Non-fail-safe Operation Modes

Comparison Table of Model


EOCR 3DM 3MZ
Protection Over - current ● ●
Under - current ● ●
Phase Loss ● ●
Phase Unbalance ● ●
Fail-safe & Non-fail-safe
Phase Reverse ● ●
Locked Rotor ● ● The tripping relay can be operated in a fail-safe or non-fail-safe mode
Ground Fault - ●
Run Monitor & Load Alert Function ● -
Application of the Fail-safe (Electrically Held) Connection
Selectable Alerting Pulse ● -
Faie safe setting in NVR mode : ON
Protection Feature The tripping relay is normally energized with control power supply

Function Dip Switch Description Application of the Non-fail-safe Connection


When motor operating current(In) exceeds preset oc”setting,
DEF
relay will trip after preset O-Time in “ot”setting.The amperage of Fail safe setting in NVR mode: OFF
Over- sw#3 on
In(operating current) does not effct on relay trip time.
current In all cases, the failure of the control voltage may not interrupt the process.
INV The tripping time of relay depends on the amperage of In(operating
sw#3 off current) according to time-current characteristics
Definite This is for idle/dry running protection
Under- time The relay operates when the operating current is less than preset
current characteristic “uc” current after preset “ut” time elapses.
Phase The relay will be operated within 3sec. when the phase failure occurs
Loss This function works during D-Time.
The relay operates within 8sec. when the current diffenence among 3
Phase phases is greater than 50%
Unbalance The calculation formula is(Max-Min)/Max current 100 〉50%

Phase on : enable
In the event of wrong phase sequence, relay will be operated in 0.1sec. ※Tolerance (3DM/ FDM / EVR Series)
Reversal Phase reversal protection function can be disabled by DIP selection.
off : disable
I<1A : ±0.1A
Current
I≥1A : ±5%
A Type: Ground fault protection is provided by the relay tripping sensed by
Ground 0.03-2.5A Zero Phase Current Transformer (Core Balanced Current Transformer) 0.05s → Within 0.05s
Fault B Type : The relay shows the leakage current during operation
Time t<1s : ±0.1s
0.5-10A (3MZ & FMZ)
t≥1s : ±5%
The setting range is 2-10 times of oc setting.
Locked If the starting current exceeds more than setting value after preset
Rotor D-Time elapses, the relay will be energized within 0.5sec.
This function is available on definite time characteristic.

The setting range is 1-10sec.


If the operating current exceeds more than 180% of preset
Stall “oc” setting the relay will be energized after preset “st” time
elapses

10 www.junxele.com
JUNXELE EOCR-3DM/3MS/3MZ
Digital Over Current Relay

LED Display Examples of Trip Cause Indication

■ Over-current Trip
Relay displays a trip, caused by maximun over-current.10.7A
which has been detected from phase L3(T/T3)
■ Under-current Trip
Relay displays a trip, caused by minimum Under-current.
1.14A which has been detected from pfase L2(S/T3)
Digital Ammeter ■ Locked Rotor Trip
Relay displays a trip, caused by locked rotor and maximum
3 phase motor currents(In) are displayed in sequence on the LED display.
current. 26.9A which has been detected from pfase L1(R/T1)

3DM
■ Locked Rotor Trip
Relay displays a trip, caused by locked rotor while
motor is working

■ Phase reversal Trip


Relay displays a trip, caused by phase reversal

■ Phase Unbalance Trip


Relay displays a trip, caused by Phase unbalance and maximum
current 2.78A which has been detected from phase L1(R/T1)
■ Phase Loss Trip
Relay displays a trip, caused by phase loss which has been
detected from phase L1(R/T1)

3MZ
■ Phase Loss Trip
Relay displays a trip, caused by phase loss which has been
detected from phase L2(S/T2)
■ Phase Loss Trip
Relay displays a trip, caused by phase loss which has been
detected from phase L3(T/T3)
■ Ground Fault Trip
Ground Fault Trip Relay displays a trip, caused by ground
fault current 0.6A which has been detected from ZCT

Time-Current Characteristic Curve


Refer to Curve-1 and Curve-2 on page 11

Digital Trip Cause Indication / Easy Troubleshooting Setting Step of 3DM

- Enter into “FAULT” mode with mode switch by depressing once Set/ Select the mode to adjust with turning
store button, then last trip cause is shown MODE
the MODE/Adjust swith CW or CCW.
- Each phase current is displayed in order whenever turn mode switch right
or left Depress the SET/store button once to
Set
start the setting
Test
This is the self-test of this product. If the relay enters into this mode, it begins Adjust the required amount with MODE/
Adjust
its count down preset value of O-time of “Ot” mode after waiting 3sec and Adjust switch
becomes trip state as showing “END” message that means this relay is
ready to work. Store Depress the SET/store button once to
- “END” message of a result of this test is also stored in “Fault” mode as memorize the setting
last trip.
- Not permitted to test this function during the operation to prevent
unnecessary trip

Reset
Pushing the RESET button or interrupting power resets the relay immediately.
Electrical remote reset is also available through the panel mounted reset
switch. The relay cannot be reset by control power interruption when the hand
reset (H-r) selected in mode.
In this case, it is possible to press the reset button on the relay facia.
Automatic reset is also available if enter into reset mode (rt:A-r) and
reset delay time is adjustable from 0.3sec to 20min

www.junxele.com 11
JUNXELE EVR
Electronic AC Voltage Relay

Features

Compact Design ■
Trip Indication & Troubleshooting → Ascertain Button

Multiple Protection Functions ■
Manual / Electrical Reset

24 Hours Trip Cause Memory ■
Ambient Insensitive
Protection
Protective Item Trip Time
Over-voltage OVR-TIME
Under-voltage UVR-TIME
Phase Loss 0.5 sec
EVR Phase Reversal 0.5 sec
Specification
Typical Wiring EVR - 220 EVR - 380 EVR - 415
Rated Voltage
220V 380V 415V
Voltage Setting OVR-VOLT 220 - 300V 380 - 460V 415 - 500V
UVR-VOLT 160 - 220V 300 - 380V 340 - 415V
Trip Time Setting OVR-TIME 0.5 - 2 sec
UVR-TIME 1 - 5 sec
Phase Loss Trip Time within 0.5 sec
Phase Reversal Trip Time within 0.5 sec (after Supply Power)
Time-current Characteristic Definite
Output Relay 1-SPDT(1C), 5A/250VAC Resistive
Reset M Manual Reset
A Automatic Reset (Reset Time = 5 sec)
Test Trip in 1 sec (after Pushing TEST Button)
ASCERTAIN S/W Trip Cause is memorized for 24 hours and
(Trip Cause Indication) Trip Cause will be indicated via LED
by pushing Ascertain S/W.
Allowable Tolerance Voltage ±5%
Time ±15%

EVR-PD
Digital AC Voltage Relay

Features

MCU & ASIC Based Compact Design ■
Trip Cause Display & Easy Troubleshooting

Multiple Protection Functions ■
Manual / Electrical / Automatic Reset

Wide Voltage Adjustment Range ■
Adjustable Reset Timer

Digital Volt Meter and Digital Setting ■
Ambient Insensitive
Protection
EVR-PD Protective Item Trip Time (EVR-PD)
Over-voltage OVR-TIME
Under-voltage UVR-TIME
Typical Wiring Phase Loss 2 sec
Phase Reversal 0.1 sec
Voltage Unbalance 3 sec
Specification
Voltage Setting Type Over-voltage (O-VOLT) Under-voltage (U-VOLT)
110 110 - 150V 80 - 120V
220 220 - 300V 160 - 240V
440 380 - 500V 300 - 440V
Trip Time Setting O-TIME 0.5 - 10 sec
U-TIME 0.5 - 10 sec
Control Voltage 220 AC/DC85 - 250V
Others AC/DC24, 48V (Optional Order)
Output Relay Mode 1-SPDT(1C)
Rating 3A/250VAC Resistive
Status Normally Energized
Reset SW3=AUTO Reset Time: 1 or 5 sec (DIP-SW4)
SW3=MAN RESET Button
Mounting PD 35mm Din-Rail / Panel

12 www.junxele.com
JUNXELE EGR
Electronic Ground Fault Relay

Features

MCU Based Compact Design ■
Trip & Run Indication LED

Ground Fault Protection with ZCT ■
Manual / Electrical Reset
Protection
Protective Item Trip Time
EGR Ground Fault O-Time

Specification
Typical Wiring
Ground Fault (GF) Type Range
Current Setting 05 50 - 500mA
10 100 - 1,000mA
20 200 - 2,500mA
Trip Time Setting O-TIME 0.2 - 2.0 sec
Reset Manual / Electrical (Push RESET Button or Interrupt
Supply Power)
Power Suppy 110 / 220VAC, 50/60Hz
Output Relay Mode/Rating 1-SPDT(1C), 3A/250VAC Resistive
Status Normally De-energized
Mounting 35mm DIN-Rail / Panel

PMR-44
Electronic Phase Monitoring Relay

Features

MCU Based Compact Design ■
Trip Cause Indication & Troubleshooting

Multiple Protection Functions ■
Manual / Electrical / Automatic Reset

2 - 15% Voltage Unbalance Setting ■
Ambient Insensitive

Fail-safe Operation
Protection
Protective Item Trip Time
Phase Reversal 0.1 sec
Phase Loss 1 sec
Voltage Unbalance 5 sec

Specification
Control Voltage Type Range
220 3Φ 160 - 300VAC, 50/60Hz
PMR-44 440 3Φ 340 - 480VAC, 50/60Hz
Reset Manual (Instantaneous) / Electrical
Automatically reset with 5 sec delay
when supply power comes to normal.
Output Relay Mode 1 - SPDT (1C)
Typical Wiring Rating 5A/250VAC Resistive
Status Normally Energized
Mounting 35mm DIN-rail/Rail

Troubleshooting

www.junxele.com 13
JUNXELE EOCR-1P
Single Phase Relay

Features

Single-phase Over Current Protection

Trip Indication LED

Definite Trip time Characteristic

Mamual (instantaneous)/Electrical (Remote) Reset

Protection
Protective Item Operating (Trip) Time
EOCR-1P
Over-current O-TIME

Specification

Current setting Type Range


05 0.5 - 8A/9A
20 2 -20A
O-TIME 0.2~15sec

Tolerance Current ±10%


Time ±15%
Trip Indication LED
Time characteristics Definite
Control Voltage 110 AC90~150V
220 AC180~260V
Frequency 50/60Hz
Insulation Between Casing & Circuits Over 10MΩ(DC 500V Mugger)
Dielectric Strength Between Casing & Circuits 2kV 50/60Hz 1min
Between Contacts 1kV 50/60Hz 1min
Between Circuits 2kV 50/60Hz 1min
Ambient Temperature Storage -30~80℃
Operation -20~60℃
Mount 35mm Din Rail Mounting

14 www.junxele.com
JUNXELE EOCR-DZ(T)
Electronic Ground Fault Relay

Features

MCU Based

Ground Fault/ Over-Current/Phase Loss/Phase Umbalance/Phase Reverse/Locked Rotor

Definite Trip time characteristic

Manual(Instantaneous)/Electrical (Remoter)Reset

Trip Indication LED

DZ: Window Type Terminal Type

EOCR-DZ+Power Terminal Kit→EOCR-DZT

Protection
Protective Item Operating(Trip)Time
Over-current O-TIME
Phase Loss 4sec
EOCR-DZ
Phase Reverse 0.1sec
Phase Unbalance 8sec
Locked Rotor 10sec
Ground Fault 0.5sec

Comparison Table of Model


PWR PL OL RP GR
Over-Current ○ ○ ● ○ ○
Ground Fault ○ ○ ○ ○ ●
Phase Reverse ○ ○ ○ ● ○
L1 Phase Loss ○ ● ● ○ ○
Phase Loss L2 Phase Loss ○ ● ○ ● ○
L3 Phase Loss ○ ● ○ ○ ●
Phase Umbalance ○ ●-○ ○ ○ ●
※LED: ON(●), OFF(○), ON-OFF(●-○)

Specification
EOCR-DZ(T)
Type Range Ground Fault
Current Setting 05 0.5~6A 0.05~0.8A
10 1.0~10A 0.05~0.8A
60 5.0~60A 0.05~0.8A
60~600 0.5 Type fitted with external CT. 0.05~0.8A
Time Setting Start-Up Delay D-TIME
Operating Delay O-TIME 30sec
RESET Manual Reset/Electrical(Remote) Reset
Time Characteristics Definite
Trip Indication 5LED
Tolerance Current ±10%
EOCR-DZT
Time ±10%
Control Voltage Voltage 110 AC85~150V,50/60Hz
220 AC180~260V,50/60Hz
Output Contacts 1-SPDT AC 250V/3A/250VC
Contacts R Type Normally Energized: 97┦┟98 Colsed
Condititon
N Type Normally De-energized: 95┦┟96 Colsed*Optional
Insulation Between Casing & Circuits Over 10MΩ(DC 500V Mugger)
Between Casing & Circuits 2kV 50/60Hz 1min
Dielectric Strength Between Contacts 1kV 50/60Hz 1min
Between Circuits 2kV 50/60Hz 1min
Storage -20~60℃
Ambient Temperature
Operation -30~80℃
Ambient Humidity 30~85%RH without Condensation
Mouting EOCR-DZ Panel
EOCR-DZT 35mm Din-Rail/Panel

www.junxele.com 15
JUNXELE DCL/DUCR
Electronic DC Current Relay

Features
■ DC Overcurrent Relay for DC Motor delay. It has easier control operation. It has DC
■ The milli-volt(mV) signals generated from Overload and DC Underload protection relays.
the Shunt and power supply are sensed by ■
It has wide DC current protection range from
solid state circuitry and compared with preset 1A to hundreds Amps.
overload setting. ■
DC Ammeter maybe used instead of Shunt
In case sensing overload condition, the (DC Ammeter has its own shunt inside and
internal relay switches contact after the preset keep 50mV maintained.)
DUCR
Protection
Protective Item DCL DUCR
Typical Wiring Over-current O-TIME -
Under-current(Dry-run) - O-TIME
Specification
Current Setting Type Setting Range(DCL) Setting Range(DUCR)
DC Over-current Relay DC Under-current Relay
70 Secondary Voltage of Shunt(10~70m VCD)
Trip time setting O-TIME 30sec(Adjustable)
Reset M Manual(Instantaneous) / Electrical(Remote)
A Auto(Instantaneous) Reset(Option)
Indication LED
Power Supply Voltage 220 110/220VAC
Other Voltage(Option)
440 380/440VAC
Frequency 50/60Hz
Auxiliary Relay N Normally Energized
R Normally De-energized
Mounting Panel

DOVR/DUVR
Electronic DC Voltage Relay

Features

Compact Design ■
Solid State DC Over-voltage / Undervoltage

Definite Trip Time-current Characteristic Protection.

Trip & Run Indication (LED)

Confirm actual current and precise setting
possible as it has Voltage Meter.
DOVR Protection
Protective Item DOVR DUVR
Typical Wiring Over-voltage O-TIME -
Under-voltage - O-TIME

Specification
Model DC Over-voltage DC Undervoltage
Voltage Setting Type Voltage Setting Range
10 1~10V -
30 3~30V 3~30V
110 10~110V 20~110V
220 20~220V 30~220V
Others Option
Trip Time Setting Trip Delay O-TIME 0.2~30sec
Reset M Manual(Instandaneous)/Electrical Rester
A Auto(Option)
Control Voltage 220 110/220VAC, 50/60Hz
Others Other voltage option
Auxiliary Relay Mode/Rating 1-SPDT(1C) 3A/250VAC Resistive
Status R Type Normally De-energized
Mounting Panel

16 www.junxele.com
JUNXELE 2CT
Current Transformer

Features

Fitted to EOCR relays for Large Amp Motor Protection

1.0 Measuring Class

For EOCR Only
Specification
Model 2CT-100 2CT-150 2CT-200 2CT-300 2CT-400
Current Ratio 100 : 5A 150 : 5A 200 : 5A 300 : 5A 400 : 5A
Class 1.0 1.0 1.0 1.0 1.0
Budden 5VA 5VA 5VA 5VA 5VA
2CT
Insulation Voltage 600VAC
Dielectric Strength 2kV
Insulation 10MΩ(500VDC Mugger)
Mounting Panel

3CT
Current Transformer

Features

Fitted to EOCR relays for Large Amp Motor Protection

1.0 Measuring Class

For EOCR Only
Specification
Model 3CT-100 3CT-150 3CT-200 3CT-300 3CT-400
Current Ratio 100 : 5A 150 : 5A 200 : 5A 300 : 5A 400 : 5A
Class 1.0 1.0 1.0 1.0 1.0
3CT Budden 5VA 5VA 5VA 5VA 5VA
Insulation Voltage 600VAC
Dielectric Strength 2kV
Insulation 10MΩ(500VDC Mugger)
Mounting Panel

ZCT
Zero Phase Current Transformer

Features

Applicable for Ground Fault Protection Devices (EGR)

Detect Zero Phase Current

For EOCR Only
Specification
Hole Dimension Type Hole
ZCT - 35 35mm
ZCT - 80 80mm
ZCT - 120 120mm
Primary GF Current 200mA
Secondary GF Current 1.5mA
Tolerance ±10%
Budden 10VA
ZCT
Rated Voltage 600VAC
Dielectric Strength 2kV
Insulation 10MΩ(500VAC Mugger)
Mounting Panel

www.junxele.com 17
JUNXELE Dimension

18 www.junxele.com
JUNXELE Dimension

www.junxele.com 19
JUNXELE LR97D/LT47
Electronic Over Current Relay

Presentation
LR97 D and LT47 electronic over current relays have been developed to satisfy machine protection requirements.
These relays have definite time characteristics: current threshold and time based function.
They are particularly recommended for providing mechanical protection on machines with high resistive torque, high
inertia and with strong probability of jamming under steady state conditions.
They can be used for motor protection in the case of long starting times or frequent starting.
The LR97 D relay also incorporates two fixed time protection functions, one of 0.5 seconds against locked rotor and
one of 3 seconds against phase failure.
LR97 D and LT47 can be used to provide mechanical shock protection. In this case, setting the O-Time knob to
minimum will ensure tripping in 0.3 seconds.

Applications
LR97D
LR97 D and LT47 relays are particularly suitable for the following machines:

Monitoring function for excessively long starting time on machines with a risk of difficult starting:

Machines with high resistive torque, high inertia machines.

Monitoring of machines during steady state operation: overtorque detection function

Machines with strong risk of jamming, machines with torque build-up over time,

Mechanical failure monitoring,

Faster detection of malfunctioning on machines where the motor is oversized in relation to its thermal protection I²t.

Motor protection for specific applications:

Machines with long starting times,

Machines with high on-load factor: more than 30 to 50 starts/hour,

Machine with fluctuating load from a steady state, where the thermal image of a thermal overload relay (thermal
memory) is unsuitable in relation to actual overheating of the motor.
Examples of machines:

Conveyors, crushers and mixers,

Fans, pumps and compressors,
LT47 ■
Centrifuges and spin-dryers,

Presses, shearing machines, saws, broaching machines, sanders and lifting hoists.

Description Operation
■ Because of their two separate time settings, LR97 D and LT47 relays can be combined with the motor-starter
LR97D
function:
■ D-Time: starting time, O-Time: trip time during steady state.
■ The D-Time function is only available during the motor starting phase. During this phase the overload detection
function is inhibited in order to allow starting. Under steady state conditions, when the motor current is greater than
the setting current due to an overload or single-phasing, the red LED lights up and the internal relay switches its
contact after a time preset by the O-Time knob.
■ The red LED stays on, indicating that the relay has tripped.
■ The relays are simple to set, in 5 easy steps:
■ Adjust the 3 knobs to maximum (Load, D-Time and O-Time),
■ Adjust the D-Time knob to the value corresponding to the motor starting time.
■ When the motor reaches steady state, adjust the Load knob (turn the knob counter-clockwise until the red LED
starts to flicker).
1 RESET knob
■ Slowly turn the Load knob clockwise until the LED goes out.
2 TEST/STOP knob
■ Set the required tripping time, using the O-Time knob.
3 Ready/Run Indicator
4 Relay tripped indicator Status Signaling
5 Current setting LR97D LT47
6 Adjustment of starting time
To assist fast diagnostics, two LEDs (one green and one red) allow Signaling of the operating status:

LT47

7 Adjustment of tripping time


8 Manual/Auto adjustment
9 Single-phase/3-phase adjustment
10 Retractable fixing lugs

20 www.junxele.com
JUNXELE LR97D/LT47
Electronic Over Current Relay

LR97D Electronic Over Current Relays


Relay Usable For use Relay Reference Weight
setting range range (1) with contactor (2) supply voltage (3)
A A kg
0.3…1.5 0.3…1.3 LC1 D09…D38 a 200…240 V LR97 D015M7 0.172
a 100…120 V LR97 D015F7 0.172
c/a 24 V LR97 D015B 0.172
c/a 48 V LR97 D015E 0.172
1.2…7 1.2…6 LC1 D09…D38 a 200…240 V LR97 D07M7 0.172
a 100…120 V LR97 D07F7 0.172
c/a 24 V LR97 D07B 0.172
c/a 48 V LR97 D07E 0.172
5…25 5…21 LC1 D09…D38 a 200…240 V LR97 D25M7 0.172
LR97D
a 100…120 V LR97 D25F7 0.172
c/a 24 V LR97 D25B 0.172
c/a 48 V LR97 D25E 0.172
20…38 20…34 LC1 D25…D38 a 200…240 V LR97 D38M7 0.172
a 100…120 V LR97 D38F7 0.172
c/a 24 V LR97 D38B 0.172
c/a 48 V LR97 D38E 0.172

LT47 Electronic Over Current Relays


Relay Usable Relay Reference Weight
setting range range (1) supply voltage
A A kg
LT47 relay with manual/electric reset
0.5…6 0.5…5 a 200…240 V LT47 06M7S 0.192
a 100…120 V LT47 06F7S 0.192
c/a 24 V LT47 06BS 0.192
c/a 48 V LT47 06ES 0.192
3…30 3…25 a 200…240 V LT47 30M7S 0.192
a 100…120 V LT47 30F7S 0.192
c/a 24 V LT47 30BS 0.192
c/a 48 V LT47 30ES 0.192
5…60 5…60 a 200…240 V LT47 60M7S 0.192
a 100…120 V LT47 60F7S 0.192
c/a 24 V LT47 60BS 0.192
c/a 48 V LT47 60ES 0.192
LT47 relay with automatic reset
0.5…6 0.5…5 a 200…240 V LT47 06M7A 0.192
a 100…120 V LT47 06F7A 0.192
c/a 24 V LT47 06BA 0.192
c/a 48 V LT47 06EA 0.192
3…30 3…25 a 200…240 V LT47 30M7A 0.192
a 100…120 V LT47 30F7A 0.192
c/a 24 V LT47 30BA 0.192
c/a 48 V LT47 30EA 0.192
5…60 5…60 a 200…240 V LT47 60M7A 0.192
a 100…120 V LT47 60F7A 0.192
c/a 24 V LT47 60BA 0.192
LT47
c/a 48 V LT47 60EA 0.192

Accessories (to be ordered separately)


Description For Sold in Unit Weight
use with lots of reference kg
Pre-wiring kits allowing connection of LC1 D09…D18 10 LAD 7C1 0.002
the LR97 D relay N/C contact directly LC1 D25…D38 10 LAD 7C2 0.003
to the contactor
Terminal block for clip-on mounting on LR97 D 1 LAD 7B106 0.100
35 mm rail (AM1 DP200)
(1) To allow adjustment of the tripping sensitivity, see adjustment method (page 24517/2)
(2) Please see pages 0246Q/2 and 0246Q/3
(3) If a pre-wiring kit is used, it is no longer possible to electrically wire Signaling of tripped status

www.junxele.com 21
JUNXELE LR97D/LT47
Electronic Over Current Relay

Auxiliary Contact Characteristics


Relay type LR97 D●●●●● LT47 D●●●●●
Contact type 1 NO/NC 1 N/O+N/C
Conventional thermal current A 3 3
Maximum hold consumption V ~24 ~48 ~110 ~220 ~24 ~48 ~110 ~220
of controlled contactor coils Conforming to IEC 60947 VA 70 140 360 360 70 140 360 360
(occasional operating cycles V …24 …48 …110 …220 …24 …48 …110 …220
of contact 95-96) W 55 55 28 28 55 55 28 28
Short-circuit protection By gG, BS fuses. Maximum A 3 3
rating or GB2 circuit-breaker
Connection by cable or lug-clamps Min. mm2 1 x 0.75 1x1
Flexible cable without cable end 1 or 2 conductors Max. mm2 2 x 2.5 2 x 2.5
Flexible cable Min. mm2 1 x 0.34 1x1
1 or 2 conductors
with cable end Max. mm2 1 x 1.5 + 1 x 2.5 2 x 2.5
External Ø of lugs mm 7 7
Ø of screw mm M3 M3.5
Tightening torque N.m 0.6…1.2 0.8…1.7

Electrical Characteristics of Power Circuit


Relay type LR97 D015●●to LR97 D38●● LT47 ●●●●
LR97 D25
Setting range Depending on model A 0.3…38 0.5…60
Tripping class Adjustable Adjustable
Rated insulation voltage (Ui) Conforming to IEC 60947-4-1 V 690 690
Conforming to UL, CSA V 600 600
Rated impulse withstand voltage (Uimp) kV 6 6
Frequency limits Of the operating current Hz 50…60 50…60
Connection by cable or lug-clamps
Flexible cable without cable end Min. mm2 1.5 2.5 -
1 conductor Max. 10 10 -
Flexible cable Min. mm2 1 1 -
1 conductor -
with cable end Max. 4 4
External Ø of lugs mm 10 12 -
Ø of screw mm M4 M4 -
Tightening torque N.m 2 2 -

Operating Characteristics
Relay type LR97 D●●●●● LR97 D●●●S LR97 D●●●S
Adjustment Current A “Load” knob “Load” knob “Load” knob
Time D-time s 0.5…30 0.5…30 -
knob
O-time s 0.2/0.3…10 0.2/0.3…10 0.2/0.3…30
knob
R-time s - - 1…120
knob
Reset Manual Reset button Reset button Reset button
Automatic 120 sfixed - R-time knob: 1-120 s
Electrical By interruption of power By interruption of power By interruption of power
supply (minimum 0.1 s) supply (minimum 0.1 s) supply (minimum 0.1 s)
Tripping On starting Steady state On starting Steady state -
Protection functions
Inhibited After Inhibited After After O-time
Overload Imax > Isetting during during
D-time O-time D-time O-time
Locked rotor, mechanical Tripping After < 0.5 s Inhibited After After O-time
jamming I > 3 x Isetting D-time during O-time
D-time
Sensitivity to phase failure Tripping <3s <3s Inhibited After O-time After O-time
during
D-time
Status and fault Signaling (see table page 24517/2) 2 LEDs 2 LEDs 2 LEDs
TEST/STOP function Test No load No load No load
Stop Under load Under load Under load
Sealing Yes Yes Yes

22 www.junxele.com
JUNXELE LR97D/LT47
Electronic Over Current Relay

LR97D Dimensions LT47 Dimensions

LR97D c Mounting LT47 Mounting


Direct mounting beneath contactor
c
b
b

67,5 45

67,5 45

LC1 D09…D18 D25…D38


b 123 137 Note: Can be mounted on rail.
C See pages 24531/2 and 24531/3

LR97D Schemes LT47 Schemes

www.junxele.com 23
JUNXELE LR9F Series
Electronic Thermal Overload Relay
Presentation

LR9F electronic protection relays are especially suited to the operating conditions of motors.
They provide protection against:
■ thermal overload of 3-phase or single-phase balanced or unbalanced circuits;
■ phase failure and large phase unbalance,
■ protracted starting times,
■ prolonged stalled rotor condition.

LR9F electronic protection relays are mounted directly below an LC1 F type
contactor. They cover a range from 30 to 630 A, in eight ratings.
The settings can be locked by sealing the transparent protective cover.
A reset button is mounted on the front of the relay.
Two versions are available:
■ simplified version: class 10: LR9 F●3●●, class 20: LR9 F●5●●.

■ conplete version: class 10, 10A or class 20, selectable, conforming to EN 60947-4-1: LR9 F●●.
This latter version includes an alarm function which makes it possible to forestall tripping by load shedding.

1.radjustment dial
2.Test button
3.Stop button
4.Reset button
5.Trip indicator
6.Setting locked by sealing the cover

Setting-up the special functions of LR9F thermal overload relays


Setting the relay
■ Lift the transparent cover 7 to gain access to the various settings.
■ Adjustment is achieved by turning dial 1 which is graduated directly in Amperes.
■ The setting can be locked by sealing the cover 6.

“Stop” function 3
Stop

■ The “Stop” function is obtained by pressing the red “STOP” button 3.


■ Pressing the Test button:
■ actuates the N/C contact,
■ has no effect on the N/O contact.
■ The “STOP” button can be locked by fitting a “U” clip
(reference: LA7 D901).

“Test” function 2
Test

■ The “Test” function is obtained by pressing the red “TEST” button 2


with a screwdriver.
■ Operation of the “TEST” button simulates tripping of the relay and:
■ actuates both the N/O and N/C contacts,
■ actuates the trip indicator 5.

Trip indicator

24 www.junxele.com
JUNXELE LR9F Series
Electronic Thermal Overload Relay
Thermal overload relays:
■ Compensated and differential,
■ With relay trip indicator,

■ For a.c.,

■ For direct mounting on contactor or independent mounting (1).

Relay Fuses to be used For direct mounting Weight


setting range with selected relay beneath contactor LC1
aM gG
A A A kg
Class 10
LR9 D5369 30…50 50 80 F115…F185 LR9 F5357 0.885
48…80 80 125 F115…F185 LR9 F5363 0.900
60…100 100 200 F115…F185 LR9 F5367 0.900
90…150 150 250 F115…F185 LR9 F5369 0.885
132…220 220 315 F185…F400 LR9 F5371 0.950
200…330 330 500 F225…F500 LR9 F7375 2.320
300…500 500 800 F225…F500 LR9 F7379 2.320
380…630 630 800 F400…F630 and LR9 F7381 4.160
F800

LR9 F5367

LR9 F7375

3-pole electronic thermal overload relays, model LR9F


Accessories (to be ordered separately)

Mounting plates for overload relay

For use with relays Reference Weight(kg)

LR9 F5●57, F5 ●63, F5●67, F5●69, F5●71, LA7 F901 0.100


LR9 F57, F63, F67, F69, F71
LA7 F901

LR9 F7●75, F7●79, F7●81, LA7 F902


LR9 F75, F79, F81

LA7 F902

www.junxele.com 25
JUNXELE LR9F Series
Electronic Thermal Overload Relay

3-pole electronic thermal overload relays, model LR9F


Operating characteristics

Relay type LR9 F5●57, F57 F5●63, F63 F5●71, F71 F7●75, F75 F7●81, F81
F5●67, F67 F7●79, F79
F5●69, F69

Rated insulation voltage (Ui) Conforming to IEC 60947-4 V 1000

Rated operational voltage (Ue) Conforming to VDE 0110 gr C V 1000


Rated impulse Conforming to IEC 60947-1 kV 8
withstand voltage (Uimp)

Rated operational current (Ie) A 30 to 630


Short-circuit protection and coordination See pages: 24540/2, 24540/3, 24544/2 and 24544/3
Frequency limits Of the operating current Hz 50…60. For other frequencies, please consult your Regional Sales Office (1)
Power circuit connections Width of terminal lug mm 20 20 25 30 LR9 F7●75 40
and LR9 F75
40 LR9 F7●79
and LR9 F79
Clamping screw M6 M8 M10 M10 M12

Tightening torque N.m 10 18 35 35 58

3-pole electronic thermal overload relays, model LR9F


Operating characteristics

Tripping class Conforming to IEC 60947-4-1 10, 10 A and 20


Temperature compensation ℃ - 20…+ 70
Reset Manual on front of relay
Fault indication On front of relay
Test function On front of relay
Stop function Actuation of N/C contact, without affecting N/O contact

Tripping thresholds Conforming to Alarm A 1.05±0.06 In


EC 60947-4-1 Tripping A 1.12±0.06 In
Sensitivity to Conforming to Tripping in 4 s ± 20 % in the event of phase failure
phase failure IEC 60947-4-1

Adjustment Setting dial on front of relay


(nominal motor current)

Security sealing Yes

26 www.junxele.com
JUNXELE LR9F Series
Electronic Thermal Overload Relay

Common side view LR9 F5●71, F71 LR9 F5●57, F5●63, F5●67,
LR9 F5●69, F57, F63, F67, F69

(1)Terminal shroud LA9 F70● (2) 6.5 x 13.5 for LR9 F5●57 and F57. 8.5 x 13.5 for LR9 F5●63, F5●67, F5●69, F63, F67, F69
Common side view LR9 F7●75, F7●79, F7●81, LR9 F7●81 (for mounting beneath LC1 F630 and F800),
LR9 F75, F79, F81 LR9 F81

(1)Terminal shroud
LA9 F70●

P1 P2
LR9 F7●75, F75 48 48
LR9 F7●79, F7●81, F79, F81 55 55

Direct mounting beneath contactor LC1 F Schemes LR9 F5●57…F7●81

Contactors LC1 With LR9 relays P1 H1 H2 H1


F115 F5●57, F5●63, F5●67, F5●69, 240 30 50 120
F57, F63, F67, F69
F150 F5●57, F5●63, F5●67, F5●69 246 30 50 120
F57, F63, F67, F69
F185 F5●57, F5●63, F5●67, F5●69 250 30 50 120
F57, F63, F67, F69
F225 F5●71, F71 273 40 50 120
F7●75, F7●79, F75, F79 308 50 58 120
F265 F5●71, F71 279 40 58 120
F7●75, F7●79, F75, F79 314 60 58 120
F330 F7●75, F7●79, F75, F79 317 60 58 120
F400 F7●75, F7●79, F7●81, F75, F79, F81 317 60 58 180
F500 F7●75, F7●79, F7●81, F75, F79, F81 346 70 58 180
F630, F800 F7●81, F81 510 110 58 180

www.junxele.com 27
JUNXELE GMP Series
Electronic Overload Relay

Ratings

Model GMP22-2P GMP22-2P(1a1b) GMP22-2S GMP22- GMP22-2T GMP22-


GMP22-3P/3PR 3S/3SR 3T/3TR
Type Pin type Screw type Tunnel type
No. of CT 2CT 2CT 3CT 2CT 3CT 2CT 3CT
Protection Overcurrent ● ● ● ● ● ● ●

Phase failure ●Note1) ● ● ● ● ● ●

Stall ● ● ● ● ● ● ●

Asymmetry _ _ ● _ ● _ ●

Reverse phase _ _ ●(3PR) _ ●(3SR) _ ●(3TR)

Current setting range(A) 0.3~1.5


1~5
4.4~22
Operating time characteristics Inverse time characteristics(GMP22-2PD: Definite time characteristics)

Time setting Inverse time 0~30 sec

(sec) Definite D-time 0.2~60 sec for GMP22-2PD


O-time 5sec (Fixed) for GMP22-2PD
Tolerance Current ±5%
Time ±5%(or±0.5sec)
Control Voltage AC 110V/220V(±10%) AC 100~260V
Power Frequency 50/60Hz
Aux. contact Contact 1SPDT(1c) Note2) 2SPST(When power applied, 1a1b)
Ratings 5A/250VAC Resistive load 3A/250VAC Resistive load
Operate (95┤├ 96 Close) (95┤├96 Close) (97┤├98 Open)
Insulation resistance Min 100M�at 500Vdc
Surge endurance(IEC 1000-4-5) 1.2×50μs�6kV Apply the standard wave
Fast transient burst(IEC 1000-4-4) 2.5kV/5min.
Environment Operation -25~70℃
Temperature Storage -30~80℃
Relative humidity 30~90%RH(No freezing)
Trip indicator Red LED Red/Green LED Red LED Red/Green LED Red LED Red/Green LED
Dimension(mm) W× ×H× ×D 44×71×78 53×77.5×87.5 53×68×87.5 53×68×87.5
Mounting type Direct mount onto a MC Separate mount(Screw or Din-rail) Note3)
Applied MC GMC-9, GMC-12, GMC-18, GMC-22

Note1) When it is 2CT model, only two-phase protection is available


Note2) 1a1b Aux. switch is optional in GMP 22-2P model
Note3) The bracket for Din-rail mount is optional

28 www.junxele.com
JUNXELE GMP Series
Electronic Overload Relay

Ratings

Model GMP40-2P GMP40- GMP40-2S GMP40- GMP40-2T GMP40- GMP80-2S GMP80-


3P/3PR 3S/3SR 3T/3TR 3S/3SR
Type Pin type Screw type Tunnel type Screw type
No. of CT 2CT 3CT 2CT 3CT 2CT 3CT 2CT 3CT
Protection Overcurrent ● ● ● ● ● ● ● ●

Phase failure ● ● ● ● ● ● ● ●

Stall ● ● ● ● ● ● ● ●
Asymmetry _ ● _ ● _ ● _ ●

Reverse phase _ ●(3PR) _ ●(3SR) _ ●(3TR) _ ●(3SR)

Current setting range(A) 4~20


16~80
8~40
Operating time characteristics Inverse time characteristics
Time setting Inverse time 0~30 sec
(sec) Reset time Manual reset (Prompt)
Reset after 1 Min.(Optional)
Tolerance Current ±5%
Time ±5%(or±0.5sec)
Control Voltage AC 100~260V
Power Frequency 50/60Hz
Aux. contact Contact 2SPST(When power applied, 1a1b)
Ratings 3A/250VAC Resistive load
Operate (95┤├96 Close) (97┤├98 Open)
Insulation resistance Min 100M�at 500Vdc
Surge endurance(IEC 1000-4-5) 1.2×50μs�6kV Apply the standard wave
Fast transient burst(IEC 1000-4-4) 2.5kV/5min.
Environment Operation -25~70℃
Temperature Storage -30~80℃
Relative humidity 30~90%RH((No freezing)
Trip indicator Red LED Red/Green LED Red LED Red/Green LED Red LED Red/Green LED Red LED 2Red LEDs
Dimension(mm) W× ×H× ×D 53×77.5×87.5 53×68×87.5 53×38×87.5 89×77.5×97.4

Direct/Separate mount
Mounting type Direct mount onto a MC Separate mount(Screw or Din-rail)
(Screw or Din-rail )
GMC-50, GMC-65,
Applied MC GMC-32, GMC-40
GMC-75, GMC-85

www.junxele.com 29
JUNXELE GMP Series
Electronic Overload Relay
Description
■ Wide and adjustable current range
■ Adjustable trip time (trip class 5-10-15-20-30)
■ Designed suitable for use with contactors
Directly mountable on the GM-9, 12, 18, 22 contactors Separate mount versions are also available Separately
mountable on 35mm DIN rail or with screws
■ 1NO+1NC trip contacts
■ Manual reset as standard (Automatic reset optional)
GMP22-3P
Extended Protective Functions

Number of sensors 2CT 3CT 3CT


Types (GMP22-□) (-2P, -2T, -2S) (-3P, -3T, -3S) (-3PR, -3TR, -3SR)
Overcurrent
Phase loss
Functions Locked rotor
Phase unbalance
Phase reversed

Selection

Mount/Connection Sensor Setting range Catalog No.


Directly on a contactor 0.3 - 1.5A GMP22 - 2P · 1.5
2-sensor
( 2 CT ) 1 - 5A GMP22 - 2P ·�5
4.4 - 22A GMP22 - 2P�· 22
0.3 - 1.5A GMP22 - 3P�· 1.5
GMP22-2P 3-sensor
( 3 CT ) 1 - 5A GMP22 - 3P�· 5
4.4 - 22A GMP22 - 3P�· 22
3-sensor 0.3 - 1.5A GMP22 - 3PR�· 1.5
Reverse phase 1 - 5A GMP22 - 3PR�· 5
detection
4.4 - 22A GMP22 - 3PR�· 22
Separate mount ① 0.3 - 1.5A GMP22 - 2S�· 1.5
2-sensor
Cable connection 1 - 5A GMP22 - 2S�· 5
( 2 CT )
with a screw ② 4.4 - 22A GMP22 - 2S�· 22
0.3 - 1.5A GMP22 - 3S�· 1.5
3-sensor
GMP22-3S ( 3 CT ) 1 - 5A GMP22 - 3S�· 5
4.4 - 22A GMP22 - 3S�· 22
3-sensor 0.3 - 1.5A GMP22 - 3SR�· 1.5
Reverse phase 1 - 5A GMP22 - 3SR�· 5
detection
4.4 - 22A GMP22 - 3SR�· 22
Separate mount ① 0.3 - 1.5A GMP22 - 2T�· 1.5
2-sensor 1 - 5A GMP22 - 2T�· 5
Connection ( 2 CT )
without a screw ② 4.4 - 22A GMP22 - 2T�· 22
- cables pass 0.3 - 1.5A GMP22 - 3T�· 1.5
through CT holes 3-sensor
1 - 5A GMP22 - 3T�· 5
( 3 CT )
4.4 - 22A GMP22 - 3T�· 22
GMP22-3T 3-sensor 0.3 - 1.5A GMP22 - 3TR�· 1.5
Reverse phase 1 - 5A GMP22 - 3TR�· 5
detection
4.4 - 22A GMP22 - 3TR�· 22

30 www.junxele.com
JUNXELE GMP Series
Electronic Overload Relay
Description
■ Wide and adjustable current range
■ Adjustable trip time (trip class 5-10-15-20-30)
■ Designed suitable for use with contactors

Directly mountable on the GM-32, 40 contactors


Separate mount versions are also available
Separately mountable on 35mm DIN rail or with screws
■ 1NO+1NC trip contacts
GMP40-3P
■ Manual reset as standard (Automatic reset optional)

Extended Protective Functions


Number of sensors 2CT 3CT 3CT
Types (GMP40-□) (-2P, -2T, -2S) (-3P, -3T, -3S) (-3PR, -3TR, -3SR)
Overcurrent
Phase loss
Functions
Locked rotor
Phase unbalance
Phase reversed

Selection

Mount/Connection Sensor Setting range Catalog No.


GMP40-3P Directly on a contactor 2-sensor 4 - 20A GMP40 - 2P · 20
( 2 CT ) 8 - 40A GMP40-2P · 40
3-sensor 4 - 20A GMP40-3P · 20
( 3 CT ) 8 - 40A GMP40-3P · 40
3-sensor 4 - 20A GMP40-3PR · 20
Reverse phase 8 - 40A GMP40-3PR · 40
detection
Separate mount ① 2-sensor 4 - 20A GMP40 - 2S · 20
( 2 CT ) 8 - 40A GMP40-2S · 40
Cable connection
with a screw ② 3-sensor 4 - 20A GMP40-3S · 20
( 3 CT ) 8 - 40A GMP40-3S · 40
GMP40-3S
3-sensor 4 - 20A GMP40-3SR · 20
Reverse phase 8 - 40A GMP40-3SR · 40
detection

Separate mount ① 2-sensor 4 - 20A GMP40 - 2T · 20


( 2 CT ) 8 - 40A GMP40-2T · 40
Connection
with a screw ② 3-sensor 4 - 20A GMP40-3T · 20
- cables pass ( 3 CT ) 8 - 40A GMP40-3T · 40
through CT holes 4 - 20A GMP40-3TR · 20
3-sensor
Reverse phase 8 - 40A GMP40-3TR · 40
detection
GMP40-3T

www.junxele.com 31
JUNXELE GMP Series
Electronic Overload Relay
Description
■ Wide and adjustable current range
■ Adjustable trip time (trip class 5-10-15-20-30)
■ Designed suitable for use with contactors GM-50, 65, 75, 85
Separately mountable on 35mm DIN rail or with screws
■ 1NO+1NC trip contacts
■ Manual reset as standard (Automatic reset optional)
■ Extended protective functions

GMP80-2S Extended Protective Functions

Number of sensors 2CT 3CT 3CT


Types (GMP80-□) (-2S) ( -3S) (-3SR)
Overcurrent
Phase loss
Functions Locked rotor
Phase unbalance
Phase reversed

Selection

Mount/Connection Sensor Setting range Catalog No.


Separate mount 2-sensor 16 - 80A GMP80-2S.80
( 2 CT )
Cable connection with a 3-sensor 16 - 80A GMP80-2S.80
screw ( 3 CT )
3-sensor
Reverse phase 16 - 80A GMP80-3SR.80
detection

Technical Information

Relay control voltage 100 to 260V AC 50/60Hz


Auxiliary contact 3A/250VAC at resistive load
1NO( 97-98 ) + 1NC( 95-96 )
Setting tolerance Current ±5%
Time ±5% ( or ±0.5sec )
Insulation resistance Min 100M�at 500V DC
Impulse withstand voltage 1.2x50μs�5kV ( IEC1000-4-5 )
Fast transient burst 2kV/5min ( IEC1000-4-4 )
Ambient temperature -25 to 70℃for operation
-30 to 80℃for storage
Humidity 30 to 90% RH

32 www.junxele.com
JUNXELE GMP Series
Electronic Overload Relays
Description
■ Small size, economical ■ Definite time characteristics
■ Delay time setting in starting and operation ■ Wide current setting range
■ Over current, phase failure protection ■ Screw or Din-rail mounting

Extended Protective Functions

Number of sensors 2CT


Types (GMP-60T)
Overcurrent
Phase loss △ Note1)
GMP60T Functions Locked rotor
Phase unbalance
Phase reversed

Ratings (Tunnel type)

Model GMP60T
Type Tunnel type
No. of CT 2
0.5~6
Current setting
3~30
range(A)
5~60
Operating time characteristics Definite time characteristics
Starting time 0.2~30
Time setting
Operating time 0.2~15
(sec.)
Reset time Manual reset
Allowable Current ±5%
error Time ±5%(or ±0.5 sec.)
Voltage 180~260V (110V / 440V) Note2
Control power
Frequency 50/ 60Hz
Contact 1SPDT(1c)
Contact configuration Aux.
Ratings 5A 250Vac, resistive load
s/w
Operation 95┤├96close
Insulation resistance Min. 50�at 500Vdc
Surge insurance(IEC 1000-4-5) 7kV(6times for 1min. Interval)
Fast transient burst(IEC 1000-4-4) 2.5kV/5min
Environment Operation -25~70℃
Temperature Storage -50~80℃
Relative humidity 46~85 RH(No freezing)
Trip indicator LED
Dimension(mm) W× ×H× ×D 72×63×69
Mounting type Separate mount(Screw & Din-rail)
Applied MC GMC-9, 12, 18, 32, 40, 50

Ordering Information
Specify catalog number

Tunnel type EMPR protects the current under 0.1A


■The tunnel type EMPR with 0.5~6A nominal current, can detect the current under 0.1A If we increase the
number of times of a wire pass through the CT (Tunnel), the EMPR can detect the lower current

No. of times to pass through Current setting range


1 0.5~6
2 0.25~3
3 0.17~2
4 0.12~1.5

www.junxele.com 33
JUNXELE GMP Series
Electronic Overload Relay
DCT( Current transformer)

Ratings
Number of sensors
2CT
Types (GMP80-□)
DCT-100 100 : 5A
DCT-150 150 : 5A
CT ratio
DCT-200 200 : 5A
DCT-300 300 : 5A
DCT-400 400 : 5A
Class 1.0
Burden 5VA
Insulation voltage 600VAC
Insulated impulse voltage 2kV
Insulation resistance 10MΩ(DC 500V Mugger)
Mounting Panel
Note: Please use DCT for LG Electronic Motor Protection Relay only.

Dimension

34 www.junxele.com
JUNXELE GMP Series
Electronic Overload Relay
GMP22-2P
GMP22-3P
GMP22-3PR

Terminal configuration : See Fig. 1 on the next page 0.18kg

GMP40-2P
GMP40-3P
GMP40-3PR

Terminal configuration : See Fig. 1 on the next page 0.20kg/0.22kg

GMP22-2S
GMP22-3S
GMP22-3SR
GMP40-2S
GMP40-3S
GMP40-3SR

GMP22-2T
GMP22-3T
GMP22-3TR
GMP40-2T
GMP40-3T
GMP40-3TR

www.junxele.com 35
JUNXELE GMP Series
Electronic Overload Relay
GMP80-2S
GMP80-3S
GMP80-3SR

GMP80-2S

Terminal configuration : See Fig. 2 0.42kg/0.46kg

Terminal Configuration

Circuit Diagram

Without additional CTs In case of using additional CTs

36 www.junxele.com
JUNXELE GMP Series
Electronic Overload Relay
GMP 60T

GMP60T

Circuit Diagram

Terminal Configuration

www.junxele.com 37
JUNXELE 3RB20 Series
Electronic Overload Relay
3RB20 for Standard Applications
3RB20 overload relays with screw connection on auxiliary current side for direct mounting1)2) and stand-alone
installation2)3), CLASS 10
Features and technical specifications:

Overload protection, phase failure protection and unbalance protection

Internal power supply

Auxiliary contacts 1 NO + 1 NC

Manual and automatic RESET

Switch position indicator

TEST function and self-monitoring

Extended protective functions


Size Rating for Set current Short-circuit DT Order Price PU PS* PG Weight
Con- induction value protection No. per PU (UNIT, per PU
tactor motor of the with fuse, SET, M) approx.
4) Rated inverse- type of
value5) time delayed coordination
overload trip 2, gL/gG
operational
class6)
kW A A

S00 0.04 … 0.09 0.1 … 0.4 2 3RB20 6-1RB0 1 1 unit 101 0.200

0.12 … 0.37 0.32 … 1.25 6 3RB20 6-1NB0 1 1 unit 101 0.200


0.55 … 1.5 1…4 20 3RB20 6-1PB0 1 1 unit 101 0.200


1.1 … 5.5 3 … 12 35 3RB20 6-1SB0 1 1 unit 101 0.200


3RB20 16-1RB0

S0 1.1 … 5.5 3 … 12 35 3RB20 26-1SB0 1 1 unit 101 0.200


3 … 11 6 … 25 3RB20 26-1QB0 1 1 unit 101 0.200


3RB20 26-1QB0

S2 3 … 11 6 … 25 35 3RB20 36-1QB0 1 1 unit 101 0.360


7.5 … 22 12.5 … 50 100 3RB20 36-1UB0 1 1 unit 101 0.230


1 1 unit 101 0.360


1 1 unit 101 0.230

3RB20 36-1UB0

38 www.junxele.com
JUNXELE 3RB20 Series
Electronic Overload Relay
Extended protective functions
Size Rating for Set current Short-circuit DT Order Price PU PS* PG Weight
Con- induction value protection No. per PU (UNIT, per PU
tactor motor of the with fuse, SET, M) approx.
4) Rated inverse- type of
value5) time delayed coordination
overload trip 2, gL/gG
operational
class6)
kW A A

S3 7.5 … 22 12.5 … 50 125 3RB20 46-1UB0 1 1 unit 101 0.560


11 … 45 25 … 100 200 3RB20 46-1EB0 1 1 unit 101 0.560


1…4 1 1 unit 101 0.450

3RB20 46-1EB0

S6 22 … 90 50 … 2003 355 3RB20 56-1FC2 1 1 unit 101 1.030


1 1 unit 101 0.690

3RB20 56-1FW2

S10/S12 22 … 110 55 … 250 500 3RB20 66-1GC2 1 1 unit 101 1.820


and size 90 … 450 160 … 630 800 3RB20 66-1MC2 1 1 unit 101 1.820

14
(3TF68/
3TF69)

3RB20 66-1MC2

1) The relays with an Order No. ending with “0” are designed for direct mounting. With the matching
terminal brackets (see Accessories) the sizes S00 and S0 can also be installed as stand-alone units.
2) The relays with an Order No. ending with “2” are designed for direct mounting and stand-alone
installation. For 3TF68/3TF69 contactors, direct mounting is not possible.
3) The relays with an Order No. ending with “1” are designed for stand-aloneinstallation.
4) Observe maximum rated operational current of the devices.
5) Standard value for 4-pole standard motors at 50 Hz 400 V AC. The actual
starting and rated data of the motor to be protected must be considered
when selecting the units.
6) Maximum fuse for overload relay, type of coordination 2. For fuse values in conjunction with contactors, see
Technical Specifications, Short-Circuit Protection with Fuses for Motor Feeders.
7) The relays with an Order No. with “W” in penultimate position are equipped with a straight-through
transformer.

www.junxele.com 39
JUNXELE RST 25
Electronic Voltage Relay

PHASE FAILURE, PHASE SEQUENCE, ASYMMETRIC,


UNDERVOLTAGE AND OVERVOLTAGE RELAY

Operation Instructions

The electronic phase relay RST 25 offers phase, philure shift, phase flashing, asymmetric, Phase sequence and
also under and overvoltage control.

Connection

The RST 25 can be connected as following in the installation diagram:


FIG1: connection of the relay before operation.
When the relay is connected as in FIG 1, the there yellow LED’ sL1, L2 and L3 light up when
RST 25 The power supply A1 phase L, the A2 Neutral, and the three phases “L1”, “L2”and “L3”are
connected.
If there is no under or overvoltage, phase failure or phase sequence, the green LED lights up,
(terminals 11 and 14 are closed )and the relay is ready for self retaining.
It is also possible to connect the power supply after operation in FIG2.
By both FIG’ s 1 and 2, the terminal “PE” must be grounded.

Undervoltage
The desired undervoltage limit can be adjusted down to-25% UN.

Asymmetry
The adjusting over-and undervoltage limit, the asymmetric limit is slso adjusted.

Time Delay

The switch off time can be adjusted by the potentiometer “Time Delay” from 0.1……5 seconds. With this
function it is possible to adjust the time for the identification of the failure.

Contactor Control

If a phase fails during operation at load or one of the contacts of the contactor or circuit Breaker is
defective,(contact bounce or scorched contacts), RST 25 recognizes the failure, And also the feedback voltage,
and switches off depending on the setting of “Time Delay”. The RST 25 controls the phase shift. If there is a
phase failure the angle from the feedback Voltage is 30°. The RST 25 recognizes this failure.

40 www.junxele.com
JUNXELE RST 25
Electronic Overload Relay

Technical Data

Mains voltage 3χ400V, 40-60Hz


Power Supply 185… 250V AC(Optional when placing order)
Power Consumption 2VA
Ambient Temperature 25° …65°
Phase Angle 120°±8°@UN=UU
Under voltage Adjustable to -25% UN
Overvoltage Adjustable to +25% UN
Tripping time 0.1…5 seconds
Life of the Instrument 20χ106 mechanical switchings
Air-gap and Leakage path Group C, 250V, VDE 0110
RST 25
Relay Output 1 C/0 contact, 16A, 250V VDE, SEV, SEMKO, AgCdO
High-voltage test 2500V
Shock voltage test 5KV VDE0435
Housing Type 1P 40, DIN 40 050
Weight 325g
Dimension H=75mm, W=45mm, D=120mm

Housing as per VDE 0304, fixed by means of snap in lock on caprail(DIN 50022-35). Non-Inflammable,
resistant to temperatures up to 150°C. Air-gap and leak resistance according Go VDE 0100. DIN 57110,
C500 VE/600 VG. Material of terminals CuSN6 gold. Cross-section of connecting Lead 2χ2.5mm2. protection
against electrical shock, M4-screws.