K
SYMBOL TEST CONDITION MIN TYP MAX MIN TYP MAX UNITS
IR VR = 400V - - 100 - - - µA
VR = 600V - - - - - 100 µA
DEFINITIONS
VF = Instantaneous forward voltage (pw = 300µs, D = 2%).
IR = Instantaneous reverse current.
trr = Reverse recovery time at dIF/dt = 100A/µs (See Figure 6), summation of ta + tb.
ta = Time to reach peak reverse current at dIF/dt = 100A/µs (See Figure 6).
tb = Time from peak IRM to projected zero crossing of IRM based on a straight line from peak IRM through 25% of IRM (See Figure 6).
RθJC = Thermal resistance junction to case.
pw = pulse width.
D = duty cycle.
80 500
100
IR, REVERSE CURRENT (µA)
175oC
IF, FORWARD CURRENT (A)
10
100oC 0.1
25oC 0.01
25oC
1 0.001
0 0.5 1.0 1.5 2.0 0 100 200 300 400 500 600
VF , FORWARD VOLTAGE (V) VR, REVERSE VOLTAGE (V)
FIGURE 1. FORWARD CURRENT vs FORWARD VOLTAGE FIGURE 2. REVERSE CURRENT vs REVERSE VOLTAGE
60 16
30 8
ta 6
20
4
tb
10 2
0
0 120 130 140 150 160 170 180
1 10 20
IF , FORWARD CURRENT (A) TC, CASE TEMPERATURE (oC)
FIGURE 3. trr , ta AND tb CURVES vs FORWARD CURRENT FIGURE 4. CURRENT DERATING CURVE
I = 1A
L = 40mH
R < 0.1Ω
EAVL = 1/2LI2 [VR(AVL) /(VR(AVL) - VDD)]
VAVL
Q1 = IGBT (BVCES > DUT VR(AVL))
L R
CURRENT +
VDD IL IL
SENSE
Q1 I V
VDD
DUT -
t0 t1 t2 t
FIGURE 7. AVALANCHE ENERGY TEST CIRCUIT FIGURE 8. AVALANCHE CURRENT AND VOLTAGE
WAVEFORMS
FAIRCHILD’S PRODUCTS ARE NOT AUTHORIZED FOR USE AS CRITICAL COMPONENTS IN LIFE SUPPORT
DEVICES OR SYSTEMS WITHOUT THE EXPRESS WRITTEN APPROVAL OF FAIRCHILD SEMICONDUCTOR CORPORATION.
As used herein:
1. Life support devices or systems are devices or 2. A critical component is any component of a life
systems which, (a) are intended for surgical implant into support device or system whose failure to perform can
the body, or (b) support or sustain life, or (c) whose be reasonably expected to cause the failure of the life
failure to perform when properly used in accordance support device or system, or to affect its safety or
with instructions for use provided in the labeling, can be effectiveness.
reasonably expected to result in significant injury to the
user.
PRODUCT STATUS DEFINITIONS
Definition of Terms
Advance Information Formative or This datasheet contains the design specifications for
In Design product development. Specifications may change in
any manner without notice.
No Identification Needed Full Production This datasheet contains final specifications. Fairchild
Semiconductor reserves the right to make changes at
any time without notice in order to improve design.
Rev. H4