Beruflich Dokumente
Kultur Dokumente
MANIKANDAN.V.P Madampillaidharmam,
Rajakrishnapuram (po),
Mobile:+91-9489131519 Rathapuram (tk)Tirunelveli Rural,
E-mail: manikandan241992@gmail.com Tamil Nadu – 627114.,
India
SUMMARY:
EDUCATION QUALIFICATION:
BE In Mechanical Engineering
COMPUTER KNOWLEDGE:
Design software ; Auto CAD, CATIA v5
Word processing : MS office
Operating System : WIN XP, Vista, 7, 8
CERTIFICATIONS:
PROFESSIONAL EXPERIENCE:
SEPARATOR
Having experience in 2 phase and 3 phase (horizontal, vertical, Sphere) separator
maintenance to change mist pad, vertex breaker, coalescing plates, deflected etc.
Involved in startup shutdown and commissioning procedure all type of separators.
Done hydro test and pneumatic test as per the procedure and pressure.
PUMPS:
Dismantling and reassembling of all centrifugal and reciprocating pumps i.e. single
and multi-stage, vertical and horizontal type. Piston pumps, chemical dosing pumps,
Methanol Injection pump, etc.
Involved in repair such as plunger changing, activities such as mechanical seal
assembling and aligning the pump with Rim and Face method, Dial Indicator.
Overhauling the Pumps and Pump Bearings, Pump flanges and shaft alignment, Shaft
sleeves and flange settings and moving parts alignment.
Change the Pump Casings, Impellers, Check the water and oil leakage of the Bearing
shaft seals, Check, replace the shaft, and Pump packing.
COMPRESSOR
Overhauling air and gas compressor both rotary as well as reciprocating, maintaining
the required clearance for piston ring gap.
Changing gas seal cups, bearing, suction and discharge valves as well as maintenance
of lube oil circuit and coolers.
PUMP ALIGNMENT
To align the pump and motor using Rim and Face method (Radial, Axial) as well as
Reverse Alignment. Using proper fittings, clamps including magnetic clamps, spacer
(shim) and get the accurate result, 0.01mm to 0.05mm. Dial indicator alignment.
Experience in Hydro test and pneumatic test of all valves, pipes, and vessels
pressurized by high pressure pump. To set the operation pressure and waiting 30
minutes, check the leakage. If the leakage occurs through the flange, tight the Flange
and continue Retest
To run the motor using motor data sheet, referring the suction and discharge pressure
value and monitoring whole status of motor and pump action as well as using vibration
meter and temperature gun to get the reading every 15 minutes and also prepare the
mechanical running log. On any fault, to attend as per instruction.
Safety Devices:
Familiar with handling of Safety Equipments, H2S Monitor, Gas Detector, Breathing
Apparatus, Fire detection systems ( U.V. Sensors, Fusible Plug etc.,) and Fire
Extinguishes.
Personal Profile:
D.O.B :24/01/1992
Father’s Name : Mr. V.PONNUSAMY
Marital status : Single
Nationality : Indian
Languages know : English, Hindi, Tamil, Malayalam
Personal Profile
Passport No : K9943998
Place of Issue : MADURAI
Date of Issue : 21/02/2013
Date of Expiry : 21/02/2023
Declaration:
I hereby declare that all details furnished above are true and correct to the best of my knowledge.
Yours sincerely
MANIKANDAN.V.P