Sie sind auf Seite 1von 103

Banyule

Standard
Drawings
This page was intentionally left blank
New
Banyule Standard Drawings
Drawing No
ROADS

Road Profiles

Typical Road Profiles Residential R 100A

Typical Road Profiles Residential R 100B

Typical Road Profiles Access & Collector R 105


Level 1 & 2

Typical Road Profiles Low Density Residential R 110


Collector/Acceess/Rural Access

Typical Road Profiles Commercial street/ R 115


Industrial Street

Kerb Profiles

Typical Kerb Profiles ‘B’, ‘SM’ & ‘M’ Type R 150

Typical Industrial Kerb Profiles ‘B’ & ‘M’ Type R 155

Open Invert Channel R 160

Typical Kerb Bedding R 165

Layback for ‘B2’ & ‘B3’ Kerbing R 170

Kerb & Channel Installation Abutting Existing Pavement R 175

Pitcher Kerb R 180

Two Pitcher Tray Kerb & Channel at Crossing R 185

Heavy Duty Kerb Adaptors for ‘B2’ and ‘SM2’ Kerbs R 190

Vehicle Crossovers

Retrofit Residential Vehicle Crossing Detail R 200

New Residential Single Vehicle Crossing Detail R 205

New Residential Shared/Double Vehicle Crossing Detail R 210

New Industrial Vehicle Crossing Detail R 215


New
Banyule Standard Drawings
Drawing No
Typical Swale Drain Vehicle Crossing R 220

Footpaths

Pedestrian Crossing R 250

Kerb Ramp R 255

Typical Footpath Detail R 260

Typical Hot Mix Asphalt Footpath R 265

DRAINAGE

Pipes and Connections

Bedding & Backfilling for Concrete Pipe Drains D 100

Anchor Blocks D 105

Drainage Pipe Anchor Block D 110

Subsurface Drain and Service Conduit Details D 115

Catch Drain Details D 120

House Drain to Kerb & Channel D 125

House Drain Connection D 130

Easement Drain Connection D 135

Property Gully Inlet D 140

Reinforced Concrete Wingwall (In – Situ) D 145

Concrete Endwall for Pipes up to 300mm in Diameter


D 150
(Walkways, Paths & Tracks)

27A Street Drain Connection D 155

27A Street Drain Connection (Limited Cover) D 160

Pit Details

Step Irons D 200

Glass Fibre Reinforced Pit Covers D 205

Junction Pit D 210

Junction Pit - Heavy Duty/Light Duty/Fibre Glass D 215


New
Banyule Standard Drawings
Drawing No
SEP Precast Lintel D 220

Side Entry Pit B-Type Kerb D 225

Side Entry Pit SM-Type Kerb D 230

Side Entry Pit With Precast Lintel D 235

Grated Side Entry Pit D 240

Grated Side Entry Pit Inlet with Concrete Surround D 245

Grating Pit for SM2 Modified Kerb & Channel D 250

Side Entry Pit with Grating D 255

Spoon Pit with Grating D 260

Extended Throat Side Entry Pit D 265

Footpath Grated Pit D 270

Combination Grate & Side Entry Pit D 275

Unhaunched Pits (Side Entry) D 280

Haunched Pits (Side Entry) D 285

Min. Wall Thickness for Reinforcement in Mass


D 290
Concrete Pits (Cast In-Situ)

Depressed Grated Pit D 295

Inlet Catch Pit D 300


Double Side Entry Pits D 305

ANCILLARY

Retaining walls

Low Side Stone Retaining Wall A 100

High Side Stone Retaining Wall A 105

Timber Sleeper Retaining Wall A 110

Reo Detail for Concrete

Reinforced Concrete Pavement Sealant Detail A 150


New
Banyule Standard Drawings
Drawing No
Reinforced Concrete Pavement Isolation Joint A 155

Reinforced Concrete Pavement Joint Detail A 160

Other

Laneway Typical Section A 200

Trenching Backfill
A 205
(Trenches within 1 m of Council Assets)
Roads
This page was intentionally left blank
Road Profiles
This page was intentionally left blank
This page was intentionally left blank
20m ROAD RESERVE

10m 10m

6.250m 6.25m

0.05m 1.5m 4.4m 3.45m 3.45m 4.4m 1.5m 0.05m

LINE OF KERB
LINE OF KERB
F/PATH NATURESTRIP LANE LANE NATURESTRIP F/PATH

0.55m

SM2 KERB
0.55m 0.6m
NBN NBN 0.3m
0.3m BERM
0.25m

SM2 KERB
BERM 0.75m

WATER/GAS ELEC.
CORRIDOR CORRIDOOR
1 IN 30 1 IN 30

FC
G RW AG
S AG
0.6m

0.4m
ELEC PIT
1.000m
SEWER
1.825m 0.4m
NBN/FIBRE OPTICS 1m BACK OF ELEC PIT
2.350m KERB
GAS 1.825m
NBN/FIBRE OPTICS
2.800m
RECYCLED WATER
1.825m
3.300m ELECTRICITY
POTABLE WATER TYPICAL CROSS SECTION
4.950m 20m ROAD RESERVE 1.825m
LIGHT POLES/TREES LIGHT POLES/TREES
( FOR DEVELOPMENT ABUTTING EXISTING
GOVERNMENT ROADS)

ALL MEASUREMENTS IN MILLIMETRES


NOTES:
LAST UPDATED JULY 2019
1. IF ROAD RESERVE WIDTH VARIES FROM TYPICAL SECTIONS THEN TYPICAL ROAD PROFILES RESIDENTIAL
A MODIFIED SECTION IS TO BE SUBMITTED AND APPROVED BY
COUNCIL.
2. WATER/GAS CORRIDOR: ASSUME WATER 100mm CONDUIT AND
GAS 50mm CONDUIT.
3. ELECTRICAL CORRIDOR: ASSUME 2x HV POWER CABLES IN 100mm
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 100A
CONDUITS AND 2x HV POWER CABLES IN 150mm CONDUITS
www.banyule.vic.gov.au
4. ALL CLEARANCES TO COUNCIL ASSETS MUST BE CONFIRMED BY
Approved by: James Kelly NOT TO SCALE
AN AUTHORIZED OFFICER. Manager Delivery & Assets
16m ROAD RESERVE
8m 8m

4.25m 4.25m

LINE OF KERB

LINE OF KERB
0.05m 1.5m 2.4m 2.4m 1.5m 0.05m
F/PATH NATURESTRIP 3.45m 3.45m NATURESTRIP F/PATH
LANE LANE
0.3m
0.3m
0.6m BERM

SM2 KERB
BERM

SM2 KERB
0.55m
WATER/GAS
CORRIDOR NBN
1 IN 30 1 IN 30

FC
G AG E
W AG
S 0.6m
R
0.4m 0.4m
ELEC PIT ELEC PIT
1.00m 1.00m
SEWER NBN/ FIBRE OPTICS
2.000m 2.000m
GAS 1m BACK OF BACK OF 1m ELECTRICITY
2.400m KERB KERB 2.400m
RECYCLED WATER LIGHT POLES/TREES
2.700m
POTABLE WATER
TYPICAL CROSS SECTION
16m ROAD RESERVE

ALL MEASUREMENTS IN MILLIMETRES

NOTES: LAST UPDATED JULY 2019


REFER TO R 100A NOTES
TYPICAL ROAD PROFILES RESIDENTIAL

Banyule's Standard Drawings


A copy can be found on Banyule's website
R 100B
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
16000

3500 (MIN) 7300 (MIN) 3500 (MIN)

50 1500 1500 50

ACCESS STREET

24000 (MIN)

6000 (MIN) 11000 (MIN) 6000 (MIN)

50 2500 2500 50

COLLECTOR STREET - LEVEL 1

34000 (MIN)

6000 (MIN) 7000 (MIN) 6000 (MIN) 7000 (MIN) 6000 (MIN)
(2x 3.5m LANES) (2x 3.5m LANES)

50 2500 2500 50

COLLECTOR STREET - LEVEL 2

ALL MEASUREMENTS IN MILLIMETRES

NOTES:
TYPICAL ROAD PROFILES ACCESS & LAST UPDATED JULY 2019
1. FOR KERB DETAIL REFER TO DRAWINGS R150, R155 COLLECTOR LEVEL 1 & 2
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 105
www.banyule.vic.gov.au
Approved by: James Kelly
Manager Delivery & Assets
NOT TO SCALE
21800

0 - 50 V.P.D. 4000 (MIN) GRAVEL


1635 1635
51 - 150 V.P.D. 4000 (MIN) SEAL
(MIN) (MIN)
+ 150 V.P.D. 6200 (MIN) SEAL

* V.P.D. = VEHICLES PER DAY


RURAL ACCESS

16000 (MIN)

8175 (MIN)

LOW DENSITY RESIDENTIAL COLLECTOR ROAD

21800

1635 1635
6200
(MIN) (MIN)

LOW DENSITY RESIDENTIAL ACCESS ROAD

ALL MEASUREMENTS IN MILLIMETRES

NOTES: TYPICAL ROAD PROFILES LOW DENSITY LAST UPDATED JULY 2019
RESIDENTIAL COLLECTOR / ACCESS /
1. FOR KERB DETAIL REFER TO DRAWINGS R150, R155
RURAL ACCESS
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 110
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
32300 (MIN)

5000 (MIN) 22000 (MIN) 5000 (MIN)

60° PARKING 60° PARKING


5100(MIN) - 6300(MAX) 5100(MIN) - 6300(MAX)

COMMERCIAL STREET

25000 (MIN)

6000 (MIN) 12500 (MIN) 6000 (MIN)

50 1500 1500 50

PARKING PARKING
PARALLEL PARALLEL
FOOTPATH FOOTPATH

INDUSTRIAL STREET

ALL MEASUREMENTS IN MILLIMETRES

NOTES: TYPICAL ROAD PROFILES LAST UPDATED JULY 2019


COMMERCIAL STREET / INDUSTRIAL
1. FOR KERB DETAIL REFER TO DRAWINGS R150, R155
STREET
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 115
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
Kerb Profiles
This page was intentionally left blank
LINE OF KERB LINE OF KERB LINE OF KERB
LINE OF KERB
40 110 300 40 110 300 40 110
190 110

40 25x25mm

25
25

25
25x25mm CHAMFER 10 25x25mm

15
150

150

150

225
R
R

125
R
CHAMFER CHAMFER

25

25

R
300

300

300
R

275
25

25
R

R
150

150

150
140
200 450 450 300

B1 B2 B3 SM1

LINE OF KERB LINE OF KERB LINE OF KERB LINE OF KERB

300 190 110 250 50 300 190 110


25x25mm
25x25mm CHAMFER (TYP.)
40 25x25mm
CHAMFER

15
CHAMFER 10 25x25mm
15

15
225

225
125

125
R
R

R
225

85
CHAMFER

75
75

75
R

40

R
R
R

R
275

275
R

250

250
150

150

140
600 600 600
150 TO 300

SM2 SM2-M (MODIFIED) SM3 EDGE STRIP


NOTES:

1. REFER TO AS. 2876-2000 CONCRETE KERBS AND CHANNELS FOR SPECIFIC


REQUIREMENTS.
2. REFER TO AUSTROADS GUIDE TO ROAD DESIGN PART 3: GEOMETRIC DESIGN FOR
THE RECOMMENDED USE OF KERBS AND CHANNELS.
3. CONCRETE SHALL BE NORMAL CLASS N25 STANDARD STRENGTH GRADE LINE OF KERB LINE OF KERB
COMPLYING WITH THE REQUIREMENTS OF AS. 1379. REFER TO VICROADS 300 300 300 300
STANDARD SPECIFICATION 703 FOR REQUIREMENTS OF CONCRETE TO BE USED IN LINE OF KERB
EXTRUSION MACHINES. 40 25x25mm 50 50
4. BEDDING TO BE COMPACTED CLASS 3 F.C.R. SUPPLIED BY THE CONTRACTOR SHARP SHARP
50 CHAMFER 10 25x25mm
UNLESS OTHERWISE DIRECTED. ( REFER R 165 ) 25 TRANSITION TRANSITION
5. INCREASE OVERALL KERB PROFILE (DEPTH OF CONCRETE):
CHAMFER
15

15

15
a) 80mm FOR COMMERCIAL PROPERTIES
R

R
R

b) 80mm WITH L8TM TRENCH MESH FOR INDUSTRIAL PROPERTIES (MESH TO HAVE
250

250

250
10
175

150
40mm COVER)

140
6. CONCRETE TO BE SMOOTH TROWELLED FINISHED ON TRAY AND KERB.
7. CONCRETE SPONGE FINISHED ON LAYBACK.
8. CONSTRUCTION JOINTS LOCATED:
- 2500mm MAXIMUM SPACING 300
- 75mm MINIMUM DEPTH 600 600
9. ELIMINATE 25mm BULLNOSE ON ALL POSITIVE FALL PEDESTRIAN CROSSINGS.
10. WIDTHS SPECIFIED IN CROSS SECTIONS ARE FACE (LINE) OF KERB MINIMUM.
11. MINIMUM CONCRETE STRENGTH TO BE 25 MPA. M1 M2 M3
12. LINE OF KERB IS USED TO DETERMINE CARRIAGEWAY WIDTHS.

ALL MEASUREMENTS IN MILLIMETRES

NOTES: TYPICAL KERB PROFILES 'B', LAST UPDATED JULY 2019


REFER TO THE NOTES ON THE DRAWING
'SM' & 'M' TYPE
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 150
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
LINE OF KERB LINE OF KERB LINE OF KERB LINE OF KERB LINE OF KERB
50
40 110 300 40 110 300 40 110 25X25mm
25
CHAMFER
(TYP.)

15
40 25x25mm

R
25

25
25

R
25x25mm CHAMFER 10

R
25x25mm
150

150

150

10
R
R
CHAMFER CHAMFER

25

25

330
280
R

255
25

380

380

380
R
230

230

220
50 75 75
300 50
50 300

200 450 450 N12 BARS @ 150mm N12 BARS @ 150mm


CENTRES OR EQUIVALENT CENTRES OR EQUIVALENT
B1 (INDUSTRIAL) B2 (INDUSTRIAL) B3 (INDUSTRIAL) EDGE STRIP (INDUSTRIAL) M1 (INDUSTRIAL)

LINE OF KERB LINE OF KERB


LINE OF KERB
300 300 300 300
ALL SET OUT TAKEN TO BACK OF
40 25x25mm 50 50 KERB UNLESS OTHERWISE SPECIFIED
SHARP SHARP
CHAMFER 10 25x25mm
TRANSITION TRANSITION 300 150 750
CHAMFER
15

15
'B' KERB
R

R
REFER PLANS (INDUSTRIAL) 15x15mm

280
280

FOR PAVEMENT BEYOND CHAMFER


230

220

LEVELS
40 25x25mm
CHAMFER

90
50 75 75 50 75 75
600 600 10

320
50

230
N12 BARS @ 150mm N12 BARS @ 150mm
CENTRES OR EQUIVALENT CENTRES OR EQUIVALENT

M2 (INDUSTRIAL) M3 (INDUSTRIAL)
APPROVED
NOTES: NOTES (CONT.): SUBGRADE
6. CONCRETE TO BE SMOOTH TROWELLED FINISHED ON TRAY AND KERB.
1200 150
1. REFER TO AS. 2876-2000 CONCRETE KERBS AND CHANNELS FOR SPECIFIC
7. CONCRETE SPONGE FINISHED ON LAYBACK.
REQUIREMENTS.
8. CONSTRUCTION JOINTS LOCATED: 75mm MIN COMPACTED DEPTH N12 BARS @ 150mm CENTRES
2. REFER TO AUSTROADS GUIDE TO ROAD DESIGN PART 3: GEOMETRIC DESIGN OR EQUIVALENT FOR FULL
FOR THE RECOMMENDED USE OF KERBS AND CHANNELS.
- 2500mm MAXIMUM SPACING "CLASS 3" (MIN) FCR BEDDING
3. CONCRETE SHALL BE NORMAL CLASS N25 STANDARD STRENGTH GRADE
- 75mm MINIMUM DEPTH LENGTH OF LAYBACK
9. ELIMINATE 25mm BULLNOSE ON ALL POSITIVE FALL PEDESTRIAN CROSSINGS.
COMPLYING WITH THE REQUIREMENTS OF AS. 1379. REFER TO VICROADS
10. WIDTHS SPECIFIED IN CROSS SECTIONS ARE FACE (LINE) OF KERB MINIMUM.
STANDARD SPECIFICATION 703 FOR REQUIREMENTS OF CONCRETE TO BE USED
11. MINIMUM CONCRETE STRENGTH TO BE 25 MPA. TYPICAL INDUSTRIAL KERB LAYBACK
IN EXTRUSION MACHINES.
12. LINE OF KERB IS USED TO DETERMINE CARRIAGEWAY WIDTHS.
4. BEDDING TO BE COMPACTED CLASS 3 F.C.R. SUPPLIED BY THE CONTRACTOR
UNLESS OTHERWISE DIRECTED. ( REFER R 165)
5. INCREASE OVERALL KERB PROFILE (DEPTH OF CONCRETE):
a) 80mm FOR COMMERCIAL PROPERTIES
b) 80mm WITH L8TM TRENCH MESH FOR INDUSTRIAL PROPERTIES (MESH TO
HAVE 40mm COVER)
ALL MEASUREMENTS IN MILLIMETRES

NOTE: TYPICAL INDUSTRIAL KERB LAST UPDATED JULY 2019


REFER TO THE NOTES ON THE DRAWING
PROFILES 'B' & 'M' TYPE
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 155
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
25
600

300

10R
50

200
80
80 80

600 OPEN INVERT CHANNEL

75 300 75

75
100

450

450 OPEN INVERT CHANNEL

NOTES:

1. CONCRETE STRENGTH TO BE 25 MPa


2. ALL DIMENSIONS ARE IN MILLIMETRES
3. AREA SHOWN HATCHED IS TO BE CUT BY TEMPLATE FOR ALL CONSTRUCTION JOINTS
4. CONSTRUCTION JOINTS TO BE NOT GREATER THAN 3m APART AND ARE TO BE AT
REGULAR INTERVALS
5. ALL OPEN INVERT CHANNELS SHALL BE LAID ON A LAYER OF 50mm COMPACTED DEPTH OF
20mm CLASS 2 FINE CRUSHED ROCK

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


OPEN INVERT CHANNEL
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 160
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
ALL SET OUT TAKEN BACK OF
KERB UNLESS OTHERWISE
SPECIFIED

LINE OF KERB

75mm MIN COMPACTED DEPTH APPROVED 150


"CLASS 3" (MIN) FCR BEDDING OR SUBGRADE KERB BEDDING TO
EXTENSION OF ROAD PAVEMENT EXTEND PAST B.O.K.
LAYERS, WHICH EVER IS GREATER

TYPICAL KERB BEDDING

NOTES:

1. BEDDING TO BE COMPACTED CLASS 3 F.C.R. SUPPLIED BY THE CONTRACTOR


UNLESS OTHERWISE DIRECTED

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


TYPICAL KERB BEDDING
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 165
www.banyule.vic.gov.au
Approved by: James Kelly
Manager Delivery & Assets
NOT TO SCALE
LINE OF KERB

ALL SET OUT TAKEN TO BACK OF


KERB UNLESS OTHERWISE
SPECIFIED

300 150 750

REFER PLANS
FOR PAVEMENT
LEVELS
15x15mm
CHAMFER
40

90
25
R
10

290
EXISTING 10R
R

ROAD SURFACE 10
150

APPROVED
SUBGRADE

1200 150

75mm MIN COMPACTED DEPTH INDUSTRIAL AREAS REQUIRE


"CLASS 3" (MIN) FCR BEDDING 3XN12 BARS @ 150mm CENTRES
OR EQUIVALENT FOR FULL
LENGTH OF LAYBACK
TYPICAL SECTION
NOTES:

1. REFER TO AS. 2876-2000 CONCRETE KERBS AND CHANNELS FOR SPECIFIC REQUIREMENTS
2. BEDDING TO BE COMPACTED CLASS 3 F.C.R. SUPPLIED BY THE CONTRACTOR UNLESS
OTHERWISE DIRECTED
3. INCREASE DEPTH OF CONCRETE
a) 80mm FOR COMMERCIAL PROPERTIES
b) 80mm WITH SL72 MESH FOR INDUSTRIAL PROPERTIES (MESH TO HAVE 40mm COVER)
4. CONCRETE TO BE SMOOTH TROWELLED FINISHED ON TRAY AND KERB
5. CONCRETE SPONGE FINISHED ON LAYBACK
6. CONSTRUCTION JOINTS LOCATED - 2500mm MAXIMUM SPACING
- 75mm MINIMUM DEPTH
7. ELIMINATE 25mm BULLNOSE ON ALL POSITIVE FALL PEDESTRIAN CROSSINGS
8. WIDTHS SPECIFIED IN CROSS SECTIONS ARE FACE (LINE) OF KERB

ALL MEASUREMENTS IN MILLIMETRES

LAYBACK FOR 'B2' & 'B3' LAST UPDATED JULY 2019

KERBING
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 170
www.banyule.vic.gov.au
Approved by: James Kelly
Manager Delivery & Assets
NOT TO SCALE
LINE OF KERB

NEW KERB PROFILE MINIMUM SEAL OVERLAP

KEY FOR ASPHALT


MATCH EXISTING
INVERTS. 600 MIN 300 MIN

SAWCUT LINE
EXISTING
PAVEMENT

75mm MIN COMPACTED DEPTH


30mm COMPACTED DEPTH TYPE N
"CLASS 3" (MIN) FCR BEDDING OR
EXISTING SUBGRADE 10mm NOM. SIZE ASPHALT U.N.O.
EXTENSION OF ROAD PAVEMENT
LAYERS, WHICH EVER IS GREATER NEW PAVEMENT COMPRISING OF:
CLASS 2 FCR COMPACTED TO MIN 98%,
DEPTH TO BE MIN 250mm OR MATCH
TYPICAL SECTION TO EXISTING PAVEMENT

NOTES:

1. REFER TO AS. 2876-2000 CONCRETE KERBS AND CHANNELS


2. BEDDING TO BE COMPACTED CLASS 3 F.C.R. SUPPLIED BY THE CONTACTOR UNLESS
OTHERWISE DIRECTED
3. CONCRETE TO BE SMOOTH TROWELLED FINISHED ON TRAY AND KERB
4. CONSTRUCTION JOINTS LOCATED - 2500mm MAXIMUM SPACING
- 75mm MINIMUM DEPTH
5. ELIMINATE 25mm BULLNOSE ON ALL POSITIVE FALL PEDESTRIAN CROSSINGS
6. WIDTHS SPECIFIED IN CROSS SECTIONS ARE FACE (LINE) OF KERB.

ALL MEASUREMENTS IN MILLIMETRES

KERB AND CHANNEL INSTALLATION LAST UPDATED JULY 2019


ABUTTING EXISTING PAVEMENT
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 175
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
CONSTANT

25
150 150
NATURE STRIP NATURE STRIP
ROAD PAVEMENT

125
ROAD PAVEMENT

200
50
200

50

150
75

50
100
200
50
BOXING LEVEL

20 MPa CONCRETE BEDDING 20 MPa CONCRETE BEDDING

ONE PITCHER KERB PITCHER EDGE STRIP


CONSTANT
25

150
NATURE STRIP
20
ROAD PAVEMENT
125

50
200

150
75
50

200 BOXING LEVEL

20 MPa CONCRETE BEDDING

TWO PITCHER KERB

CONSTANT

25

150
NATURE STRIP

20
125

ROAD PAVEMENT
50
200

150
75
50

200 BOXING LEVEL


20
20 MPa CONCRETE BEDDING

THREE PITCHER KERB


NOTES:

1. PITCHER SIZES QUOTED ARE AN AVERAGE SIZE ONLY.


2. ALL GROUTED JOINTS TO BE AVERAGE 20mm WIDE BY DEPTH OF PITCHER FLUSH FINISH ONLY.
MORTAR TO BE CHARCOAL COLOURED.
3. PITCHERS TO BE BROOMED AFTER GROUTING HAS BEEN PLACED TO REMOVE EXCESS GROUTING.
4. WHEN RECONSTRUCTING EXISTING THE NUMBER OF PAVERS IS TO MATCH ORIGINAL DETAIL
5. WHEN INSTALLING NEW PAVERS THE PATTERN IS TO BE CONSISTENT WITH SURROUNDING AREA OR AS
DIRECTED BY THE ENGINEER.

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


PITCHER KERB
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 180
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
TWO KERB PITCHERS & ONE CONCRETE VEHICLE CROSSING
LAYBACK PITCHER CUT TO FIT

CHANNEL INVERT

KERB TRANSITION

LAYBACK PITCHER SET TO


GRADE OF VEHICLE CROSSING
CONC
RETE 20
VEHIC
LE CR 20
OSSING ROAD PAVEMENT
50

150

50 200
BOXING LEVEL

20 MPa CONCRETE BEDDING

SECTION A-A TWO PITCHER CHANNEL

NOTES:

1. PITCHER SIZES SHOWN ARE AVERAGE SIZES ONLY. USE PITCHERS OF BEST FIT
2. ALL GROUTED JOINTS TO BE AVERAGE 20mm WIDE BY DEPTH OF PITCHER, FLUSH FINISH
ONLY. MORTAR TO BE CHARCOAL COLOURED.
3. PITCHERS TO BE BROOMED AFTER GROUTING HAS BEEN PLACED, TO REMOVE EXCESS
GROUTING.
4. FOR REVERSE FALL CROSSINGS INVERT TO TOP OF LAY BACK DIMENSION 100mm.

ALL MEASUREMENTS IN MILLIMETRES

TWO PITCHER TRAY KERB & LAST UPDATED JULY 2019


CHANNEL AT CROSSING
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 185
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
B2 KERB ADAPTOR
INSERT 100mm DIA
KERB ADAPTOR

EXISTING B2 KERB
PROFILE

B2 KERB ADAPTOR B2 KERB WITH HEAVY


DUTY KERB ADAPTOR
SECTIONAL VIEW

INSERT 100mm DIA


KERB ADAPTOR

SM2 KERB ADAPTOR

EXISTING SM2 KERB


PROFILE

SM2 KERB WITH HEAVY DUTY


SM2 KERB ADAPTOR KERB ADAPTOR
SECTIONAL VIEW
NOTES:

ALL KERB ADAPTORS ARE TO BE AN APPROVED


PROPRIETARY PRODUCT CONSTRUCTED FROM HEAVY
DUTY HOT DIPPED GALVANIZED MILD STEEL. KERB
IS TO BE NEATLY SAW CUT & KERB ADAPTOR EPOXIED
INTO POSITION. B2 KERB ADAPTOR NOW AVAILABLE IN
GALVANIZED STEEL.

ALL MEASUREMENTS IN MILLIMETRES

HEAVY DUTY KERB ADAPTORS FOR LAST UPDATED JULY 2019


'B2' AND 'SM2' KERBS
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 190
www.banyule.vic.gov.au
Approved by: James Kelly
Manager Delivery & Assets
NOT TO SCALE
This page was intentionally left blank
Vehicle Crossovers
This page was intentionally left blank
TRANSITION FROM EXISTING 100mm THICK
(FOOTPATH IN VEHICLE CROSS OVER)
TO 150mm THICK OVER 1 BAY
3000
TRANSITION (Max 6000)

PROPERTY A LINE

EJ

EJ
MATCH EXIST

EXIST.FOOTPATH 1

1
EXIST.FOOTPATH

N)
MI
Pa TJ
5M
SPLAY TO BE ( 2 AL
AB R DOWELS BARS AT 600 CTS MAX
DDA COMPLIANT SL NT
.C. H CE
VARIES

R S
K
IC ME
TH 2
m SL7 SL72 MESH REINFORCEMENT
5m CENTRALLY PLACED ON
NATURE STRIP 12
BARS CHAIRS
TJ
LAY
750

BACK NATURE STRIP

TJ
TJ

KERB & CHANNEL


LIP OF KERB
A
DOWEL BARS TO BE
750 4000 (MIN) - 6000 (MAX) 750 USED WHEN NEW
LAYBACK FORMED
PLAN

150mm THICK R.C. SLAB 25MPa MIN (DESIRABLE GRADE 1 IN 15,


ABSOLUTE MAX 1 IN 10 REFER CLAUSE 12.9.1)
TOOLED
JOINT
40mm CROSSFALL DOWEL 750mm LAYBACK
ACROSS FOOTPATH BAR

75mm MIN COMPACTED DEPTH KERB & CHANNEL


"CLASS 3" 20mm FCR BEDDING

FOOTPATH

IF REVERSE FALL IS REQUIRED


LEGEND
DESIGN OF VEHICLE CROSSING EJ
TO BE ON A SITE SPECIFIC BASIS CROSS SECTION A-A EXPANSION JOINT
TJ
TOOLED JOINTS
NOTES:

1. THIS DRAWING DETAILS DIMENSIONS FOR STANDARD RESIDENTIAL CROSSINGS ONLY.


2. CROSSING WIDTHS EXCEEDING THE MAXIMUM ALLOWABLE WILL REQUIRE APPLICATION FOR SPECIAL CONSIDERATION.
3. JOINTS AND DOWEL BARS ARE REQUIRED ON EITHER SIDE OF THE CROSSING AT THE INTERFACE WITH THE FOOTPATH.
PROVISION SHALL BE MADE IN EXISTING CONCRETE SECTIONS BY DRILLING HOLES TO A MINIMUM DEPTH OF 150mm AND
INSERTING R12 X 300mm LONG DOWEL BARS.
4. AN APPROVED JOINT FILLER SHALL BE PLACED ON EITHER SIDE OF THE CROSSING AGAINST FOOTPATH SLABS. DOWEL BARS
ARE TO HAVE AN APPROVED BOND BREAKER APPLIED TO THE END OF THE BAR INSERTED INTO THE EXISTING CONCRETE
FOOTPATH SECTIONS REFER A 155.
5. ADDITIONAL TOOLED JOINT REQUIRED IF DISTANCE FROM BACK OF KERB TO FOOTPATH IS GREATER THAN 3000 AND SHALL BE
PLACED AT THE MIDPOINT OF THE DISTANCE.
6. THE MAXIMUM NUMBER OF CROSSINGS, WHERE ANY CROSSING EXCEEDS 3.5 METRES WIDTH, SHALL BE ONE (1) CROSSING
WITH THE MAXIMUM WIDTH OF THAT CROSSING TO BE 6.0 METRES. CROSSINGS TO ADJACENT PROPERTIES SHALL BE EITHER
FULLY COMBINED, AND OF MAXIMUM WIDTH OF 6.0 METRES, OR ELSE HAVE A MINIMUM SEPARATION OF 9 METRES.
7. FOOTPATHS OF 75mm THICKNESS ARE ACCEPTABLE ONLY WHERE THE LOTS ARE DEVELOPED ALREADY AND THE RISK OF SITE
CONSTRUCTION DAMAGE IS NEGLIGIBLE. WHERE GREENFIELD SITES AND FUTURE HOUSING IS STILL TO BE DONE, THEN THE
DEPTH OF THE FOOTPATH SHALL BE 125mm THROUGHOUT.

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


RETROFIT RESIDENTIAL VEHICLE
CROSSING DETAIL
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 200
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
EXISTING 100mm FOOTPATH
3000 MIN
TO BE REMOVED AND REPLACED
5600 MAX
WITH 150mm THICK SL72 REINFORCED
25MPa CONCRETE A
PROPERTY / BUILDING LINE

FOOTPATH
WHERE ANY NEW CONCRETE ABUTS EXISTING
1500
CONCRETE INSTALL R14Ø DOWELS IN 150mm
THICK CONCRETE DOWELS @ MAX 150 CTS

NATURE STRIP
INFILL SECTION

NATURE STRIP
VARIES

PLACE SL72 MESH CENTRAL


TO 25MPa CONCRETE OR GREATER
PAVING USING BAR CHAIRS

LAY
750

BACK
BACK OF KERB

LIP OF KERB
EXTENT OF KERB & CHANNEL TO REMOVE A
ANY DAMAGE TO ROAD SEAL TO BE REINSTATED 750 750
BY CONTRACTOR TO COUNCILS APPROVAL 4500 MIN
7100 MAX

BOUNDARY
PLAN

LINE
25MPa CONCRETE 1500mm 50
EXISTING ROAD (DESIRABLE GRADE 1IN15, MAX 1IN10)
PAVEMENT
750mm LAYBACK 40mm CROSSFALL
ACROSS FOOTPATH
MATCH INTO
EXISTING TOK 150

50
50 50mm MIN COMPACTED DEPTH
"CLASS 3" 20mm FOR BEDDING

75mm MIN COMPACTED DEPTH


"CLASS 3" 20mm FOR BEDDING

BOUNDARY
SECTION A-A (STANDARD)

LINE
EXISTING ROAD 125
PAVEMENT 1500mm 50
750mm LAYBACK
40mm CROSSFALL
MATCH INTO ACROSS FOOTPATH
EXISTING TOK
150

50 50
50mm MIN COMPACTED DEPTH
"CLASS 3" 20mm FOR BEDDING
25mm DISHED CHANNEL (FOR IDEAL
SITUATION, CAN BE MODIFIED TO SUIT
75mm MIN COMPACTED DEPTH LOCAL CONDITIONS WITH APPROVAL)
"CLASS 3" 20mm FOR BEDDING
SECTION A-A (REVERSE FALL)
(ONLY TO BE USED WITH COUNCILS APPROVAL)

NOTES:
LEGEND:
1. BULL NOSE MAY BE APPLICABLE FOR GRADES STEEPER
THAN 1IN15 CONSTRUCTION JOINTS
2. LAYBACK & CROSSOVER, TO BE CONSTRUCTED IN PLAIN
CONCRETE ONLY (NO COLOURED CONCRETE BEYOND
PROPERTY BOUNDARY) T.O.K. DENOTES TOP OF KERB.
3. STIPPLE FINISH REQUIRED

ALL MEASUREMENTS IN MILLIMETRES

NEW RESIDENTIAL SINGLE LAST UPDATED JULY 2019


VEHICLE CROSSING DETAIL
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 205
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
EXISTING 75mm FOOTPATH 3000 STANDARD 3000 STANDARD
BE REMOVED AND REPLACED
WITH 125mm THICK SL72 REINFORCED
25 MPA CONCRETE
A PROPERTY / BUILDING LINE

EJ

EJ
FOOTPATH

WHERE ANY NEW CONCRETE ABUTS EXISTING


1500mm

CONCRETE INSTALL R14Ø DOWELS IN 125mm


500 500 THICK CONCRETE OR R10Ø DOWELS IN 75mm
THICK CONCRETE DOWELS @ MAX 600 CTS

NATURE STRIP PLACE SL72 MESH CENTRAL TO


INFILL SECTION

25 MPA CONCRETE PAVING


USING BAR CHAIRS
VARIES

7200 MAX
NATURE STRIP

LAY
750

BACK
BACK OF KERB

LIP OF KERB
A
600 600
EXTENT OF KERB & CHANNEL TO REMOVE
ANY DAMAGE TO ROAD SEAL TO BE REINSTATED

BOUNDARY
BY CONTRACTOR TO COUNCILS APPROVAL

PLAN

LINE
25MPa CONCRETE 1500mm 50
EXISTING ROAD (DESIRABLE GRADE 1IN15, MAX 1IN 10)
PAVEMENT
750mm LAYBACK 40mm CROSSFALL
ACROSS FOOTPATH
MATCH INTO
EXISTING TOK 125

50
50 50mm MIN COMPACTED DEPTH
"CLASS 3" 20mm FOR BEDDING

75mm MIN COMPACTED DEPTH

BOUNDARY
"CLASS 3" 20mm FOR BEDDING
SECTION A-A (STANDARD)

LINE
EXISTING ROAD 125
PAVEMENT 1500mm 50
750mm LAYBACK
40mm CROSSFALL
MATCH INTO ACROSS FOOTPATH
EXISTING TOK

150

50 50mm MIN COMPACTED DEPTH 50


"CLASS 3" 20mm FOR BEDDING
25mm DISHED CHANNEL (FOR IDEAL
SITUATION, CAN BE MODIFIED TO SUIT
75mm MIN COMPACTED DEPTH LOCAL CONDITIONS WITH APPROVAL)
"CLASS 3" 20mm FOR BEDDING
SECTION A-A (REVERSE FALL)
(ONLY TO BE USED WITH COUNCILS APPROVAL)

NOTES:

1. LAYBACK & CROSSOVER, TO BE CONSTRUCTED IN PLAIN CONCRETE ONLY (NO


COLOURED CONCRETE BEYOND PROPERTY BOUNDARY) T.O.K DENOTES TOP OF KERB. LEGEND:
2. REINFORCEMENT MESH TO BE CENTRALLY PLACED.
3. 150mm CONCRETE DEPTH WITH BAR CHAIRS. CONSTRUCTION JOINTS

EJ
EXPANSION JOINT

ALL MEASUREMENTS IN MILLIMETRES

NEW RESIDENTIAL SHARED / DOUBLE LAST UPDATED JULY 2019


VEHICLE CROSSING DETAILS
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 210
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
EXISTING 100mm FOOTPATH
BE REMOVED AND REPLACED
WITH 200mm THICK SL72 (2 No. LAYERS)
REINFORCED 32 MPA CONCRETE

EXTEND 200mm REINFORCED 32 MPA 6500 STANDARD


CONCRETE 500mm BEYOND VEHICLE
CROSSING AT THE FOOTPATH

A PROPERTY / BUILDING LINE


FOOTPATH
1500mm

PLACE SL72 MESH CENTRAL TO


INFILL SECTION

25 MPA CONCRETE PAVING


USING BAR CHAIRS
VARIES

7200 MAX

LAY
750

BACK
BACK OF KERB

A LIP OF KERB

600 EXTENT OF KERB & CHANNEL TO REMOVE 600


ANY DAMAGE TO ROAD SEAL TO BE REINSTATED

BOUNDARY
BY CONTRACTOR TO COUNCILS APPROVAL

PLAN

LINE
(25 MPa CONCRETE) 1500mm 50
EXISTING ROAD
PAVEMENT
40mm CROSSFALL
750mm LAYBACK 50mm (SL82) ACROSS FOOTPATH
MATCH INTO
EXISTING TOK 200

50
50 50mm MIN COMPACTED DEPTH
"CLASS 2" 20mm FOR BEDDING

75mm MIN COMPACTED DEPTH


"CLASS 3" 20mm FOR BEDDING
SECTION A-A (STANDARD)

NOTES:

1. T.O.K DENOTES TOP OF KERB


2. TOOL JOINT TO BE DETERMINED ON SITE LEGEND:
3. CONCRETE COVER FOR CROSSOVER 200MM WITH 2xSL72
REINFORCED WITH BAR CHAIRS CONSTRUCTION JOINTS
4. CROSSFALL GRADE AT 1 IN 10

ALL MEASUREMENTS IN MILLIMETRES

NEW INDUSTRIAL VEHICLE LAST UPDATED JULY 2019


CROSSING DETAIL
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 215
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
VARIES VARIES

CULVERT TO EXTEND
0.5m (MIN) PAST EDGE
OF CROSSING
REFER TO R 205 (BOTH SIDES)
4000 MIN (MAX 6000)

EDGE OF SEAL

(MAX 6000)
3000 MIN
A A

150 THICK R.C. (25 MPA MIN) VEHICLE


CROSSING WITH SL72 MESH 50mm
BELOW TOP.

LOW PROFILE CONCRETE ENDWALL AT


EACH END OF CULVERT (REFER D 150
FOR DETAILS). INSTALL PRECAST
CONCRETE DRIVEABLE ENDWALL (BOTH
ENDS OF CULVERT) WHEN ENDWALL IS
WITHING 1.5m OF THE EDGE OF SEAL. NOTES:
1. THIS ARRANGEMENT IS INTENDED FOR
RURAL LOW DENSITY RESIDENTIAL ACCESS

BOUNDARY
PROPERTY
WAYS.
2. COUNCIL RESERVES THE RIGHT TO DIRECT
THE USE OF CULVERT END WALL TYPE.
3. THIS IS A TYPICAL CROSSING PLAN. SLIGHT
VARIATIONS MAY OCCUR AFTER INSPECTION
AND APPROVAL OF LOCATION BY COUNCIL.
4. PRIOR TO THE CONSTRUCTION, THE
CROSSING LOCATION SHALL BE APPROVED
BY COUNCIL.
5. ALL WORKS TO BE COMPLETED TO THE
SATISFACTION OF COUNCIL.
6. MAINTENANCE OF THE CROSSOVER REMAINS
THE RESPONSIBILITY OF THE LAND OWNER.
7. DRIVEABLE ENDWALLS TO BE USED WITHIN
VERGE 1.5m OF THE EDGE OF SEAL
8. FOR ACCURATE CLEAR ZONE GUIDELINES
REFER TO AUSTROADS 'GUIDE TO ROAD
DESIGN - PART 6: ROADSIDE DESIGN, SAFETY
AND BARRIERS' TABLE 4.1: 'CLEAR ZONES
PLAN DISTANCES FROM EDGE OF THROUGH
TRAVELLED WAY'
9. TABLE DRAINS ARE NOT TO BE CLOSER THAN
1.0m FROM FENCE LINES OR SERVICES.
10. CULVERT TO BE LOCATED AT LEAST 600mm
FROM EDGE OF SEAL
125 THICK R.C. (25 MPA MIN) 11. PIPE DIAMETER MIN IS 225 OR GREATER PIPE
TABLE VEHICLE CROSSING WITH SL72 SIZE TO BE DETERMINED BY AUTHORISED
PAVEMENT SHOULDER DRAIN MESH 50mm BELOW TOP. OFFICER
12. CROSSING PAVEMENT TO BE SEALED WHERE
ABUTS A SEALED ROAD.
13. GATE OFFSET DIMENSIONS:

STANDARD VEHICLE MINIMUM GATE OFFSET FROM


TYPE EDGE OF THROUGH LANE (m)
CAR (5.0m) 8.2
FINE CRUSHED ROCK BACK FILL FOR 50 THICK CLASS 3 FINE CRUSHED RIGID TRUCK (12.0m) 12.5
R.C.P. UNDER VEHICLE CROSSING. ROCK BEDDING LAYER SEMI (19.0m) 22

SECTION A-A B-DOUBLE (25.0m) 28

ALL MEASUREMENTS IN MILLIMETRES

TYPICAL SWALE DRAIN LAST UPDATED JULY 2019


VEHICLE CROSSING
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 220
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
This page was intentionally left blank
Footpaths
This page was intentionally left blank
50 - NEW AREAS
300 - EXIST. AREAS 1500

EJ

NATURE STRIP
T
EN
M
N
IG
AL
G
150 - 'B' TYPE

IN
D
300 - 'SM' TYPE

IL
U
/B
T
EE
R
50-NEW AREAS ST
300-EXIST AREAS
RADIUS VARIES T.P.

CONTRACTION JOINTS

750
EJ

EJ
A A
1500

1500
750
RADIUS VARIES

R IP
ST 600 MIN
R E
TU
NA
NATURE STRIP

EJ

LEGEND

EXPANSION JOINT EJ
600
CONTRACTION JOINTS
T.P.

150 FOR 'B' TYPE


300 FOR 'SM' TYPE 750 1500 750

TYPICAL ARRANGEMENT PLAN

FOOTPATH PRAM CROSSING (KERB RAMP)


NOTES:
1. LOCATION OF CROSSING, GRADE AND DIMENSIONS TO BE CASE BY
1500 MAX
CASE & TO BE APPROVED BY COUNCIL.
1 IN 8 MAX 2. CROSSING GENERALLY TO BE LOCATED AT TANGENT POINTS.
3. CONCRETE TO BE SMOOTH TROWELLED FINISH ON TRAY.
4. CONCRETE TO BE FINE SOFT HAIR BROOM FINISH ON LAYBACK.
5. MINIMUM CONCRETE STRENGTH TO BE 25MPA.
6. BEDDING TO BE COMPACTED CLASS 3 (OR BETTER) F.C.R.
SUPPLIED BY THE CONTRACTOR UNLESS OTHERWISE DIRECTED.
7. IF SPRAY IS NOT REQUIRED FOOTPATH IS TO CONTINUE THROUGH
TO LAYBACKS.
50mm COMPACTED DEPTH
8. TGI'S (TILES), WHERE REQUIRED, ARE TO BE INSTALLED TO
OF CLASS 3, 20mm NOM. SIZE 600
AS1428.4
FINE CRUSHED ROCK.

SECTION A-A

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


PEDESTRIAN CROSSING
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 250
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
FOOT

B
PATH

1500 MIN

100

ROLLOVER
KERB (SM2)
BARRIER
100-190 KERB (B2)

A 1520 MAX A

INVERT CHANNEL
OF

PLAN B

900 1000 MIN 900


WING WING

ELEVATION A-A

DOWEL JOINT
REFER NOTE 5 1:8 DESIRABLE MAX BARRIER KERB (B2)
300 300

FOOTPATH

50mm COMPACTED 100


CLASS 2 CRUSHED
ROCK BEDDING 190
1520 MAX
SECTION B-B
NOTES:
FILLET INVERT
500 MIN RADIUS 1. CONCRETE THICKNESSES SHOWN THUS: 100
150 2. CONCRETE STRENGTH TO BE 25MPa.
125 3. CROSSINGS WITHIN INDUSTRIAL AREAS TO BE
40 REINFORCED WITH SL72 MESH
4. ADJACENT NATURE STRIP AREAS TO BE TOPSOILED &
SEEDED
150 5. 5. R12 DOWELS @ 500 CRS, TO BE PROVIDED WHERE
FOOTPATH IS CONSTRUCTED BEFORE CROSSING
INFILL

300 300
LAYBACK DETAIL
ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


KERB RAMP
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 255
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
SL72 MESH PLACED CENTRALLY
50 - NEW AREAS
THROUGHOUT 25 MPA (MIN) CONCRETE
300 - EXIST. AREAS
PAVING USING BAR CHAIRS.
B
BOUNDARY LINE

TJ
TJ

TJ

TJ

TJ

EJ
(3000mm SHARED PATH)
1500mm STANDARD F.P

REFER TO NOTE 3
900
A C
225

EXPANSION JOINT
225mm DISHED CHANNEL TO BE C B
CONSTRUCTED IN VERGE
REVERSE FALL SITUATIONS
WHERE APPROVED BY COUNCIL
PLAN

SL72 MESH SLAB REINFORCEMENT CENTRAL


(ONLY IN VEHICLE PART OF FOOTPATH AT 150mm DEEP
TJ

TJ

TJ

TJ

TJ
EJ

D
50mm THICK LAYER OF CLASS 3 FCR
BEDDING COMPACTED TO 90% MODIFIED
SECTION A-A
TYPICAL 100mm & 150mm FOOTPATH SECTION
1500mm FOOT PATH (3000mm SHARED PATH)

SL72 MESH SLAB 50


75 BOUNDARY LINE
REINFORCEMENT CENTRAL
1 IN 40 CROSSFALL LEGEND:
D

EXPANSION JOINT

50mm THICK LAYER OF CLASS 3 FCR TOOLED JOINTS


NATURE STRIP BEDDING COMPACTED TO 90% @ 900mm CRS.
MODIFIED
SECTION B-B
TYPICAL 100mm & 150mm FOOTPATH SECTION

25
FALL FALL

NOTES: NATURE STRIP


1. 'D' = DEPTH OF CONCRETE FOOTPATH
TYPICAL RESIDENTIAL 'D'= 100mm THICK (25 MPa)
TYPICAL VEHICLE CROSSOVER 'D'= 150mm THICK (25 MPa)
TYPICAL INDUSTRIAL / COMMERCIAL 'D' = 150mm (32MPa)
2. TOOLED JOINTS TO BE MADE WITH T-IRON
3. 900mm SPACING FOR NEW SUBDIVISIONS. 75 225
4. FOR EXISTING FOOTPATH, SPACING FOR THE BAYS WILL DISHED CHANNEL
BE DETERMINED BY AUTHORISED OFFICER SECTION C-C
(ONLY TO BE USED WITH COUNCIL APPROVAL)
ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


TYPICAL FOOTPATH DETAIL
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 260
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
50 - NEW AREAS
300 - EXIST. AREAS REFER TO NOTE 1
B
BOUNDARY LINE
(3000mm SHARED PATH)
1500mm STANDARD F.P
225

225mm DISHED CHANNEL TO BE B


CONSTRUCTED IN VERGE
REVERSE FALL SITUATIONS
WHERE APPROVED BY COUNCIL
1800mm OVERLAY

PLAN

1500mm (3000mm SHARED PATH)

50 BOUNDARY LINE
75

1 IN 40 CROSSFALL
D

NATURAL
SURFACE

40mm COMPACTED DEPTH TYPE 'N' ASPHALT (SIZE 7mm)

100mm THICK LAYER OF CLASS 2 FCR (FOOTPATH MIX)

TYPICAL 140mm ASPHALT FOOTPATH SECTION


NOTES:

1. 'D' = DEPTH OF ASPHALT FOOTPATH TYPICAL ASPHALT


FOOTPATH DEPTH 'D'= 140mm VARIED 'D' MAY OCCUR
DEPENDANT ON CBE TYPE
2. ALL PLUMBER CUTS 90° FROM THE FRONT OF THE
PROPERTY TO THE KERB & CHANNEL, MUST BE
REINSTATED FROM THE FRONT OF THE PROPERTY TO
THE BACK OF KERB WITH AN OVERLAY OF 1.8 METERS.
3. ALL PLUMBER CUTS RUNNING PARALLEL TO PROPERTY
LINE MUST BE REINSTATED FROM PROPERTY BOUNDARY
TO BACK OF KERB OR NATURESTRIP.
4. ALL WORKS TO BE COMPLETED TO THE SATISFACTION OF
COUNCIL

ALL MEASUREMENTS IN MILLIMETRES

TYPICAL HOT MIX LAST UPDATED JULY 2019


ASPHALT FOOTPATH
Banyule's Standard Drawings
A copy can be found on Banyule's website
R 265
www.banyule.vic.gov.au
Approved by: James Kelly
Manager Delivery & Assets
NOT TO SCALE
Drainage
This page was intentionally left blank
Pipes and Connections
This page was intentionally left blank
FINISHED SURFACE
C REINSTATEMENT TO EXTEND 500mm BEYOND EITHER SIDE OF TRENCH
500
L
UNDISTURBED PAVEMENT
REINSTATEMENT PAVEMENT TO MATCH OR EXCEED
PERFORMANCE OF EXISTING

BACKFILL
150 COMPACTED FINE CRUSHED ROCK
MIN

HAUNCH ZONE
D/2

COMPACTED FINE CRUSHED ROCK


BED ZONE
ROCK/SOIL 50mm COMPACTED FINE CRUSHED ROCK

TRENCHES UNDER PAVEMENT AND/OR K&C

FOR ALL UTILITY TRENCHES UNDER ALL EXISTING PAVED AREAS, ALL PROPOSED
PAVED AREAS SHOWN ON THE DRAWINGS AND ALL FUTURE ROAD PAVEMENTS

150 C FINISHED SURFACE


MIN L
BACKFILL
50mm OF APPROVED TOPSOIL FOR NATURE STRIPS.
150mm OF APPROVED TOPSOIL FOR ALL OTHER AREAS.
BACKFILL
TO INFLUENCE LINE

COMPACTED ORDINARY FILL WITHOUT


STONES IN EXCESS OF 100mm MAX. DIMENSION
MIN 300

OVERLAY ZONE
COMPACTED ORDINARY FILL WITHOUT
STONES IN EXCESS OF 50mm MAX. DIMENSION
D
HAUNCH ZONE
D/2

COMPACTED FINE CRUSHED ROCK


BED ZONE
ROCK/SOIL 50mm COMPACTED FINE CRUSHED ROCK
E
N
LI

TRENCH BEHIND KERB & CHANNEL


E
C
EN
U
FL

C
&
IN

K FINISHED SURFACE
45

F NATURAL GROUND SURFACE


O
150 C
MIN L BACKFILL
50mm OF APPROVED TOPSOIL FOR NATURE STRIPS.
150mm OF APPROVED TOPSOIL FOR ALL OTHER AREAS.

BACKFILL
COMPACTED ORDINARY FILL WITHOUT
STONES IN EXCESS OF 100mm MAX. DIMENSION
MIN
150

OVERLAY ZONE
COMPACTED ORDINARY FILL WITHOUT
STONES IN EXCESS OF 50mm MAX. DIMENSION
D
HAUNCH ZONE
D/2

COMPACTED FINE CRUSHED ROCK


BED ZONE
50mm COMPACTED FINE CRUSHED ROCK
ROCK/SOIL
TRENCH IN NATURE STRIP
NOTES:

1. TRENCH WIDTH TO BE NOMINAL DIAMETER OF PIPE PLUS 300mm UNDER ROADWAYS, 225mm LONGITUDINAL TO ROAD.
2. ALL F.C.R. TO BE 20mm MAX. SIZE 'A' GRADE MATERIAL UNLESS OTHERWISE SPECIFIED.
3. ALL BACKFILLING AND BEDDING TO BE COMPACTED AS SPECIFIED.
4. FOR BEDDING & BACKFILLING FOR PLASTIC PIPES REFER TO MANUFACTURER'S SPECIFICATION.

ALL MEASUREMENTS IN MILLIMETRES

BEDDING & BACKFILLING FOR LAST UPDATED JULY 2019


CONCRETE PIPE DRAINS
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 100
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
FINISHED
A SURFACE

150 TRENCH WIDTH = EXT. PIPE 150


MIN DIAMETER + 300mm MIN

MIN
150
END VIEW

BOTTOM OF TRENCH

MIN
150
A
FINISH
E D
SURFA
CE

150
MIN

NOTES:
MIN
150

1. WHERE POSSIBLE, ANCHOR BLOCKS


TO BE LOCATED AT PIPE JOINTS.
2. PITS MAY BE REGARDED AS ANCHOR
BLOCKS.
3. ANCHOR BLOCKS NOT REQUIRED FOR
GRADES FLATTER THAN 1IN10.
PIPE

DRAIN
SECTION A-A

BOTTO
M OF T
RENCH
MIN
150

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


ANCHOR BLOCKS
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 105
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
WIDTH OF TRENCH
(O.D. +300)

150
O.D.
* 'O.D.' DENOTES OUTSIDE DIAMETER

150

225

ELEVATION

300

RUBBER RING JOINT


150
O.D
225

75
PIPE BEDDING

COLLAR TO BE LOCATED
UPSTREAM OF ANCHOR
PLAN

NOTES:

1. FOR USE ON PIPE AT GRADES OF 1IN10 OR GREATER.


2. TO BE CONSTRUCTED AT A MAXIMUM OF 10m CTRS.
3. CONCRETE STRENGTH TO BE 25MPa.

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


DRAINAGE PIPE ANCHOR BLOCK
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 110
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
MARK APPROPRIATE SYMBOL (W,G,E,T,O)
ON FACE OF KERB BOTH SIDES OF ROADWAY

375 PAVEMENT
MIN

SUBGRADE
MIN
100
MIN
300

CONDUIT
GRADE 1:100 MIN.

SIZE 10 SCREENINGS OR TYPE A FILTER MATERIAL AS


SPECIFIED OR SHOWN ON THE DRAWINGS.
MIN
25

225
MIN

65 MIN NOM. DIAMETER


'AGROFLEX' SUBSURFACE DRAIN
WITH FILTERSOK (IF SPECIFIED)

NOTES:

1. SUBSURFACE DRAINS ARE TO BE CONNECTED TO DRAINAGE PITS.


2. ALL CONDUIT DETAILS TO BE AS PER RELEVANT AUTHORITY'S REQUIREMENTS.
3. ALL ROADWAY CONDUIT POSITIONS ARE TO BE CLEARLY IDENTIFIED ON BOTH SIDES OF THE ROADWAY BY
THE APPROPRIATE SYMBOL (EG. W (WATER), G (GAS) ETC.) IMPRESSED INTO THE FACE OF THE KERB
VERTICALLY ABOVE THE CONDUITS.

ALL MEASUREMENTS IN MILLIMETRES

SUBSURFACE DRAIN AND LAST UPDATED JULY 2019


SERVICE CONDUIT DETAILS
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 115
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
NATURAL
SURFACE

300
6:1
6:1
100mm DEPTH TOPSOIL OR
HYDROMULCH AS SPECIFIED

TYPICAL GRASS CATCH DRAIN SECTION

TOPSOIL OR HYDROMULCH
AS SPECIFIED
NATURAL TYPE 1, 150mm DIA. MIN.
SURFACE ROCK BEACHING GRASS
AS SPECIFIED

300
6:1 6:1

300
300

50mm CRUSHED ROCK


OR NATURAL GRAVEL
GEOTEXTILE AS SPECIFIED
AS SPECIFIED

TYPICAL BEACHED CATCH DRAIN

NOTE:
COMPACTED EARTH
MOUND 1. CATCH DRAINS SHALL BE CONSTRUCTED
UNDISTURBED WHERE INDICATED ON ALIGNMENT PLANS.
300 NATURAL SURFACE 2. CATCH DRAINS LOCATION RELATIVE TO THE
BATTER SHALL BE DETERMINED BY THE
150 MIN COUNCIL REPRESENTATIVE.
6 TO 1
1 3. CATCH DRAINS SHALL BE GRADED TO
4 TO
CULVERTS OR EXISTING LOW POINTS.
4. CATCH DRAINS SHALL BE LINED WITH TOPSOIL
OR HYDROMULCH AS SHOWN.
5. REFER TO D 300 FOR INLET CATCH PIT
DETAILS.

TYPICAL MOUNDED CATCH DRAIN

UNDISTURBED
NATURAL SURFACE
FIL
LB
AT
TE
R
STRIPPED SURFACE

TYPICAL CATCH DRAIN AT TOE OF BATTER

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


CATCH DRAIN DETAILS
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 120
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
LINE OF KERB

INSPECTION SHAFT TO TEMPORARILY EXTEND 300


ABOVE FINISHED SURFACE LEVEL (WITH PUSH ON CAP)
DURING CONSTRUCTION PHASE OF WORKS.

CONCRETE FOOTPATH
'SM2' PROFILE
125mm DEPTH WITH SL72 MESH

PROPERTY LINE
'HEAVY DUTY KERB ADAPTORS FOR
B2 & SM2 KERBS' FOR FURTHER DETAIL.
LINE OF KERB

SEWER CLASS M - PVC 50mm COMPACTED DEPTH OF TEMPORARY CAP


'B2' PROFILE PIPE 150Ø ONLY APPROVED BEDDING SAND

DESIGN MINIMUM GRADE 1:100


ABSOLUTE MINIMUM GRADE 1:150

TYPICAL CROSS SECTION

NOTES:

1. LOCATION OF HOUSE DRAINS WITHIN PROPERTY BOUNDARY


TO BE MARKED WITH AN APPROVED TAPE TIED TO EXTEND
THROUGH FINISHED SURFACE FOR EASY LOCATION BY
BUILDERS.
2. F.C.R. BACKFILL TO BE USED UNDER ROAD PAVEMENT

ALL MEASUREMENTS IN MILLIMETRES

HOUSE DRAIN TO KERB & LAST UPDATED JULY 2019


CHANNEL
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 125
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
WHERE A CHANGE OF GRADE IS NECESSARY,
CONSTRUCT THIS SECTION OF DRAIN AS SHOWN CEMENT
BELOW IN TYPE 2 MORTAR
BAND

FOOTPATH GRADE 1:40 KERB


ADAPTOR

150 Ø PIPE MIN. GRADE 1 in 100

300x300x75 CONCRETE PAD


HOUSE DRAIN TYPE 1 ROAD
PAVEMENT

Ø100-150 THREADED
MIN 100mm, MAX 200mm SOCKET AND CAP.
INVERT 300 BELOW TOP OF KERB

ROAD
AS REQUIRED PAVEMENT
27A

15 FOOTPATH GRADE 1:40



PV
C

MIN. GRADE 1 in 40

SEE DETAIL FOR CONNECTION

100-150 Ø PIPE
HOUSE DRAIN TYPE 2 LENGTH AS REQUIRED

PROVIDE MINIMUM 80 mm WIDE THICK


CONCRETE BAND AROUND FAUCET
BEND MAIN DRAIN REINFORCING INTO BAND
AROUND FAUCET

80 - 150 MAX
POINT UP JOINT WITH CEMENT MORTAR

CUT FAUCET FLUSH WITH INSIDE OF MAIN DRAIN

FOR MAIN DRAINS 300 Ø PROVIDE 300 WIDE x 80 MIN


THICKNESS CONCRETE COLLAR AROUND MAIN
>Ø300mm DRAIN

CONNECTION DETAILS

NOTES:

1. FOR PIPES SMALLER THAN Ø300mm A PIT MUST BE CONSTRUCTED OVER PIPE TO COUNCIL SPECIFICATIONS.
2. A27 CONNECTION TO BE CONSTRUCTED VERTICALLY TO TOP OF PIPE, UNLESS PIPE DIAMETER IS GREATER THAN 600mm
WHERE CONNECTION IS TO BE MADE WITHIN TOP 1/3 OF PIPE.
3. WHERE CONNECTION CANNOT BE MADE IN ACCORDANCE WITH THIS STANDARD, A JUNCTION PIT MUST BE
CONSTRUCTED
4. FOR KERB ADAPTOR DETAILS REFER DRAWING R 190

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


HOUSE DRAIN CONNECTIONS
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 130
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
450 x 450 GRATED
COLLECTION PIT
40

NATURAL
SURFACE
CAST IN 1.0m (MIN) 100Ø SN6 SWJ
U-PVC PROPERTY CONNECTION
STUB AT 1 IN 100 GRADE (MIN).
STUB TO BE CAPPED IF FOR FLOW
30
FUTURE CONNECTION.

VARIES 500 MIN.


DEPTH TO PIPE
150Ø SN8 SWJ U-PVC RISER

20mm NOM SIZE CLASS 3 FINE CRUSHED


ROCK COMPACTED TO 95%MODIFIED
RELATIVE COMPACTION IN 150mm THICK
LAYERS

CONNECT TO STORMWATER PIPE WITH 150Ø


'CONCONECT' OR APPROVED EQUIVALENT. TO BE
INSTALLED AS PER MANUFACTURERS
RECOMMENDATIONS. RISER TO JOIN WITH PIPE
CONNECTOR VIA SWJ.

EASEMENT DRAIN
DIAMETER VARIES

WEAVE STYLE GRATE


TO BE USED
SIDE ELEVATION
EASEMENT
DRAIN
258 GRATE TO BE CLASS B "BICYCLE SAFE"
A IN ACCORDANCE WITH
AUSTRALIAN STANDARDS
258

40
FINISH
SURFAC
ED 6 FINISHED
E SURFACE
100

DEPTH VARIES
PROPERTY
CONNECTION

190
258

A 258 100 450 100


EASEMENT
DRAIN

SECTION A-A
COLLECTION PIT - PLAN
NOTES:
1. EDGE CONCRETE AROUND PERIMETER OF GRATE.
2. TOP OF GRATE 40mm (MIN) BELOW FINISHED SURFACE.
3. DO NOT BOND GRATE TO CONCRETE TO ALLOW EASY ACCESS TO PIT.
4. CONCRETE TO BE SMOOTH TROWELLED FINISH.
5. GRATE FRAME TO BE OILED IF INSTALLED IN WET CONCRETE.
6. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS
7. SEAL UP AND MAKE GOOD PIPE CONNECTION / INSERTION TO PIT.
8. PROPERTY CONNECTION MIN 150Ø PIPE
9. AS THE DEPTH VARIES THE SIZE OF THE INLET PIT CHANGES
CORRESPONDINGLY.

ALL MEASUREMENTS IN MILLIMETRES

EASEMENT DRAIN LAST UPDATED JULY 2019

CONNECTION
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 135
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
A A

PLAN

SURFACE
NATURAL
2
1:
2 1: MIN 100
MAX 300

50

PRECAST 450 DIA CONCRETE DISH


SECTION A-A WITH 150 DIA CAST IRON GRATE

150 DIA SHAFT TO BARREL DRAIN.


SEE S.D. D 130 FOR CONNECTION DETAILS.

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


PROPERTY GULLY INLET
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 140
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
TYPE 1 TYPE 2 TYPE 3
*SLOPE AT 1.5:1 *SLOPE AT 2:1 *SLOPE AT 3:1

B C D F B C D F B C D F

138 1037 197 240 138 1129 262 320 275 1312 393 480

221 1286 315 385 294 1433 420 513 441 1727 630 769

307 1547 438 535 409 1752 584 713 613 2161 876 1069

394 1804 563 687 525 2066 750 916 788 2591 1125 1373

* THEORETICAL SLOPE WINGWALL MEASURED AT RIGHT ANGLES TO THE ROADWAY


** A2= A + E + EXTERNAL DIAMETER OF PIPE A
# APPROXIMATE ONLY 200 E 200

NOM EXTERNAL
PIPE PIPE A** E H
DIA DIA*
300 362 762 300 531
375 445 845 300 610 A2/2

B
450 534 934 300 692 B
525 616 1016 300 775
FOR LARGER PIPE DIAMETERS REFER
TO VICROADS SD1931 REV 8
A2
A
H

SEE NOTE 1 200


400

400 D
APPROX 200
END ELEVATION 12 DIA BAR
SL CONTINUOUS
OP
E* AROUND TOP
20 OF STRUCTURE.
200 200

SIZE AND EXTENT


40
OF BEACHING TO
BE DESIGNED TO
F

BEDDING AS 40 CONTROL EROSION


35°
SPECIFIED
D

200 SECTION A-A


B A B 164
C

SECTION B-B
NOTES:
200
1. PIT TO BE CONSTRUCTED IN 2 STAGES 2-TOP 500mm OF PIT IN
CONJUNCTION WITH KERB AND CHANNEL.
50 2. WHERE PIT AT LOW POINT CONSTRUCT - 100mm DIA, P.V.C. PIPE
WITH CONSTRUCTION WORKS TO DRAIN WATER FROM PAVEMENT.
V

3. AT LOW POINT TRANSITION 600mm BOTH SIDES.


4. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS.
5. FIBERGLASS PIT LIDS WITH EA FRAME AND LIGHTWEIGHT LOCKING
200

LID OR APPROVED EQUIVALENT CONSTRUCTED AND INSTALLED IN


50 ACCORDANCE WITH AS3996 MAY BE USED INSTEAD OF CONCRETE.
6. PRECAST LINTEL TO MATCH REQUIRED KERB TYPE (SM2,B2)

SECTION A-A
V = VARIABLE HEIGHT OF
THE WINGWALL

ALL MEASUREMENTS IN MILLIMETRES

REINFORCED CONCRETE LAST UPDATED JULY 2019


WINGWALL (IN-SITU)
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 145
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
A

TOP OF BATTER

INDICATES A CURVED AND


GRADED SURFACE

TOE
TOE

SIZE AND EXTENT OF


BEACHING TO BE DESIGNED
A
TO CONTROL EROSION

PLAN

1 No. N12 BAR


PLACED CENTRALLY 400
200
TOP OF BATTER

800 +PIPE O.D.Ø

END ELEVATION
230
200

NOTES:
100
1. COMPACTION PRESSURE BEHIND ENDWALLS IS NOT TO EXCEED
12.5kPa. REFER (1.5 TONNE VIBRATORY ROLLER).
2. A MAXIMUM PIPE SIZE OF 300Ø FOR THIS ENDWALL ARRANGEMENT.
3. NOT TO BE USED WHERE GENERAL VEHICULAR TRAFFIC IS PRESENT,
(MAINTENANCE OR EMERGENCY VEHICLES EXCEPTED).
4. ALTERNATIVELY PRECAST ENDWALL MAY BE USED WHERE
APPROVED BY COUNCIL.
5. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS.

SECTION A-A

ALL MEASUREMENTS IN MILLIMETRES


CONCRETE ENDWALL FOR PIPES UP TO LAST UPDATED JULY 2019
300mm IN DIAMETER (WALKWAYS, PATHS &
TRACKS)
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 150
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
INSPECTION SHAFT TO TEMPORARILY EXTEND
500 ABOVE FINISHED SURFACE LEVEL DURING
CONSTRUCTION PHASE OF WORKS.

THE LETTER 'D' IS TO BE


PROPERTY LINE IMPRINTED IN THE FACE
300 MIN.
OF KERB (40mm HIGH)
REINSTATE WITH
INSTALL SEEDED TOPSOIL
PAVER AT TO 100mm DEPTH
FINISHED
300x300x50
SURFACE
LINE OF KERB
LEVEL TO I.O.
150 FINISHED

150
600 BELOW TOP OF KERB
(DESIRABLE MINIMUM)

SCREW
ON CAP
EXISTING/NEW
150Ø SN6 SWJ
KERB PROFILE
U-PVC RISER FOR
INSPECTION
OPENING

SUB-BASE PAVEMENT LAYER


CONNECTION
FUTURE PROPERTY

100Ø SN6 150-100Ø 150Ø SN6 SWJ


SWJ U-PVC REDUCER U-PVC 'T' JUNCTION
'T' JUNCTION OFFSET TAPER
CONNECT TO STORMWATER PIPE
WITH 150Ø 'CONCONECT' OR
APPROVED EQUIVALENT. TO BE
100Ø MIN PIPE SIZE INSTALLED AS PER MANUFACTURERS
RECOMMENDATIONS. RISER TO JOIN
WITH PIPE CONNECTOR VIA SWJ.
PROPERTY CONNECTION
POINT TO BE CAPPED.

NOTES:
1. REFER TO PLUMBING CODE OF AUSTRALIA FOR
ALL PIPE LAYING AND JOINTING REQUIREMENTS.

TYPICAL CROSS SECTION

ALL MEASUREMENTS IN MILLIMETRES

27A STREET DRAIN LAST UPDATED JULY 2019


CONNECTION
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 155
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
INSPECTION SHAFT TO TEMPORARILY EXTEND
500 ABOVE FINISHED SURFACE LEVEL DURING
CONSTRUCTION PHASE OF WORKS. REINSTATE WITH SEEDED
TOPSOIL TO 100mm DEPTH

PROPERTY LINE
300 MIN.
THE LETTER 'D' IS TO BE IMPRINTED IN
THE FACE OF KERB (40mm HIGH)
INSTALL
FINISHED PAVER AT
SURFACE 300x300x50
LEVEL TO I.O.
150 FINISHED

LINE OF KERB
600 BELOW TOP OF KERB
(DESIRABLE MINIMUM)

300
SCREW ON CAP
150Ø SEWER SN6 EXISTING/NEW
U-PVC RISER FOR KERB PROFILE
INSPECTION OPENING
FUTURE PROPERTY
CONNECTION

100Ø SEWER 150-100Ø SUB-BASE PAVEMENT LAYER


250 MIN.

SN6 U-PVC REDUCER


'T' JUNCTION OFFSET TAPER 150Ø SEWER CLASS
M-PVC 'Y' JUNCTION

150Ø CONNECT TO
STORMWATER PIPE WITH
100Ø MIN PIPE SIZE
45°

'CONCONECT' OR APPROVED
EQUIVALENT. TO BE INSTALLED
AS PER MANUFACTURERS
PROPERTY CONNECTION
RECOMMENDATIONS.
POINT TO BE CAPPED.

TYPICAL CROSS SECTION


NOTES:
1. 1. REFER TO PLUMBING CODE OF AUSTRALIA FOR
ALL PIPE LAYING AND JOINTING REQUIREMENTS.

ALL MEASUREMENTS IN MILLIMETRES

27A STREET DRAIN LAST UPDATED JULY 2019


CONNECTION (LIMITED COVER)
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 160
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
This page was intentionally left blank
Pit Details
This page was intentionally left blank
PIT WALL

A A
24 DIAM BAR

200

40
350

PLAN
75

250
STEP IRON DETAIL

300
PLAN VIEW

50
25

MAX
300

STEP IRON DETAIL


SECTION VIEW

SECTION A-A
NOTES:

1. PITS DEEPER THAN 900mm SHALL BE FITTED WITH STEP IRONS


2. STEP IRONS SHALL BE LOCATED:
-DIRECTLY BELOW THE OPENING IN THE COVER
-DESIRABLY ON A WALL WITHOUT PIPE OPENINGS
-DESIRABLY ON ONE OF THE LONG SIDES OF THE PIT
3. MATERIAL FOR STEP IRONS SHALL BE STRUCTURAL GRADE 250 TO AS1204
4. STEP IRONS SHALL HAVE SHARP EDGES ROUNDED AND BE HOT DIP GALVANISED AFTER FABRICATION
5. APPROVED PROPRIETORY STEP IRONS MAY BE USED AND SHALL BE INSTALLED ACCORDING TO THE
MANAFACTURERS INSTRUCTIONS

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


STEP IRONS
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 200
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
LIGHTWEIGHT GLASS FIBRE REINFORCED PIT COVER
WITH STEEL SURROUND

75x50x5 GALVANISED
GROUT TO FILL 50 GAP
IRON FRAME
BETWEEN TOP OF PIT
WALL AND FRAME

LINTEL

50 SPACER

50
10 DIA x 100
DYNABOLT

JUNCTION PIT SECTION SIDE ENTRY PIT SECTION

1100

50 X 5 CORNER SECTION
800

WELDED FLUSH WITH TOP

FRAME DETAIL

LIGHTWEIGHT GLASS FIBRE REINFORCED 1085


PIT LID
40
40
785

6 RECESS

LOCKING MECHANISM TO BE ALL


STAINLESS STEEL COMPONENTS AND
BE USED WITH MATCHING LIFTING
HANDLE
LID DETAIL
NOTES:

1. ALL DIMENSIONS ARE IN MILLIMETRES


2. THESE LIDS ARE TO BE USED ON ALL NEW PITS AND PIT RECONSTRUCTIONS WITHIN NATURE STRIPS,
EASEMENTS AND RESERVES
3. FOR LIDS WITHIN THE ROAD CARRIAGEWAY USE RELEVANT RATED GATIC LID OR AN APPROVED
EQUIVALENT
4. DETAILS GIVEN ARE BASED ON PIT LIDS SUPPLIED BY 'TERRA FIRMA ENGINEERING P/L'.
OTHER APPROVED MANUFACTURERS MAY BE USED. LOCKING MECHANISMS MUST USE THE SAME KEY.
5. DIMENSIONS GIVEN ARE FOR 900x600 JP's AND 900x675 SEP'S.

ALL MEASUREMENTS IN MILLIMETRES

GLASS FIBRE REINFORCED PIT LAST UPDATED JULY 2019


COVERS
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 205
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
PIT LID AS PER STD DWG
D 205

A
NOTCH STEP IRONS
65 DIA. WEEPHOLES
IF SPECIFIED: SEE NOTE 3
T L OR SUBSURFACE
DRAIN CONNECTIONS SEE NOTE 5.
L/2 L/2 ON UPHILL SIDE
OR ABUTTING
ROAD PAVEMENT

NOMINAL DEPTH TO OUTLET


1 HOUSE DRAIN
W/2

CONNECTION
:2
AS SPECIFIED
W

W/2

Ø
A

CONCRETE
PIT CHAMBER SHAPED TO
SETOUT POINT PIPE INVERT
FOR HALF DIA.

PLAN SECTION A-A

WALL
INTERNAL SIZE MAX DEPTH MAX PIPE DIA
THICKNESS
(L X W) (D) (ø)
(T)
600 X 600 900 300 150
900 X 600 2400 600 150
1000 X 750 2400 750 150
LARGER SIZES TO BE SPECIFIED BY ENGINEER

NOTES:

1. PIT WALLS ARE TO BE REINFORCED WITH SL72 MESH UNLESS SPECIFIED OTHERWISE
2. PIT WALLS ARE TO BE PLASTERED AS REQUIRED TO PRODUCE A SMOOTH CHAMBER
WITHOUT VOIDS
3. USE STEP IRONS AS PER VICROADS STD DWG 1041 OR AN APPROVED EQUIVALENT FOR
ALL PITS DEEPER THAN 900.
4. LIDS AND FRAMES AS SPECIFIED IN STD DWG D 205.
5. PROVIDE LIGHTWEIGHT COMPOSITE PIT LID AS PER BCC STD DWG D 205.
6. PROVIDE 100mm DEEP NOTCH IN WALL WHERE SPECIFIED FOR TABLE DRAIN INLET.

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


JUNCTION PIT
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 210
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
PIT WIDTH 'W' A A
W/2

PLAN
FINISHED SURFACE LEVEL

VARIES BETWEEN HEAVY


& MEDIUM DUTY PIT LIDS

REINFORCEMENT MESH TO BE
PLACED CENTRALLY

FLOW
150 FLOW

REINFORCEMENT DETAILS
PIT LENGTH 'L'
REINFORCEMENT
OR WIDTH 'W'

UP TO 1200 SL92

150 PIT LENGTH 'L' 150 1201 TO 1800 RL918


REFER PIT SCHEDULE
1801 TO 2400 RL1218

SECTION A-A MINIMUM PIT SIZES (EASEMENTS)


PIT DEPTH PIT SIZE

< 1000 600 x 600


NOTES:
1000 to 1200 600 x 900
1. HEAVY DUTY COVERS TO BE USED WHEN SUBJECT TO TRAFFICABLE
LOADS (AS3996 CLASS D - 210 kN) OR APPROVED EQUIVALENT. > 1200 900 x 900
MEDIUM DUTY COVERS TO BE USED IN OFF ROAD USE
(AS3996 CLASS B - 80kN) OR APPROVED EQUIVALENT.
2. CONCRETE STRENGTH FC = 25MPa. (MIN) AT 28 DAYS.
3. JUNCTION PIT IN ROAD RESERVE TO HAVE MINIMUM INTERNAL PIT
DIMENSIONS OF 600 X 900. MINIMUM PIT SIZES (ROAD RESERVE)
PIT DEPTH PIT SIZE

< 1200 600 x 900

> 1200 900 x 900

ALL MEASUREMENTS IN MILLIMETRES

JUNCTION PIT - HEAVY DUTY/LIGHT DUTY/ LAST UPDATED JULY 2019


FIBRE GLASS

Banyule's Standard Drawings


A copy can be found on Banyule's website
D 215
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
1350

375
5 No 12 DIAM MS RODS -
25 MIN COVER
900

75
ELEVATION 225

LINTEL TO BE CONSTRUCTED
USING 25 Mpa CONCRETE
VIBRATED IN MOULD

PLAN (B-TYPE)
76

CHANNEL INVERT 110

75 75

100
125
150
100

225
100

375
250

150
180 75
80

225
300

SECTION B-B SECTION A-A


1350

350

5 No 12 DIAM MS
RODS - 25 MIN COVER 900

75 ELEVATION 225
300

LINTEL TO BE CONSTRUCTED
USING 25 Mpa CONCRETE
VIBRATED IN MOULD

PLAN (SM-TYPE)
ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


SEP PRECAST LINTEL
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 220
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
PIT LID AS PER STD DWG D 220
150 150
LINTEL

10
0
450 MIN

850 MIN
75 COLLAR FOR AG DRAIN
CONNECTION

250
HOUSE DRAIN
CONNECTION
POINT
450

150 675 150

SECTION A-A

PRECAST RC LINTEL AS PER


STD DWG D 220
SECTION B-B
TOP OF KERB

INVERT OF CHANNEL

150
2000

900
150

150
PLAN
NOTES:

1. PIT LID AS PER D 205


2. STEP IRONS TO USED FOR PITS WITH DEPTHS GREATER THAN 900mm.
3. WHENEVER DOUBLE SEP's ARE NEEDED CONSTRUCT TWO SEPARATE
PITS 300 APART.
4. HOUSE DRAIN CONNECTION COLLARS ARE TO BE LOCATED TO GIVE
ADEQUATE FALL FROM LOWEST POINT OF ALLOTMENT.

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


SIDE ENTRY PIT B-TYPE KERB
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 225
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
PIT LID AS PER
BCC STD DWG
B022

10
450 MIN

0
15
0
75

HOUSE DRAIN
CONNECTION
POINT

90
COLLAR
150 675 150 FOR AG DRAIN
CONNECTION
SECTION A-A
SECTION B-B

PRECAST RC LINTEL AS PER


STD DRG B026
TOP OF KERB

150
HANNEL

900
INVERT OF C

150

PLAN

NOTES
1. PIT LID AS PER BCC STD DWG D205.
2. STEP IRONS TO USED FOR PITS WITH DEPTHS GREATER THAN 900mm.
3. WHENEVER DOUBLE SEP's ARE NEEDED CONSTRUCT TWO SEPARATE
PITS 300 APART.
4. HOUSE DRAIN CONNECTION COLLARS ARE TO BE LOCATED TO GIVE
ADEQUATE FALL FROM LOWEST POINT OF ALLOTMENT.

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


SIDE ENTRY PIT SM-TYPE KERB
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 230
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
INTERNAL OPENING OF
COVER 600mm x 350mm D

TRANSITION
NOTES:

KERB

600mm
1. PIT TO BE CONSTRUCTED IN 2 STAGES 2-TOP 500mm OF PIT
IN CONJUNCTION WITH KERB AND CHANNEL.
2. WHERE PIT AT LOW POINT CONSTRUCT - 100mm DIA, P.V.C. B
PIPE WITH CONSTRUCTION WORKS TO DRAIN WATER FROM
PAVEMENT. 150
3. AT LOW POINT TRANSITION 600mm BOTH SIDES.
4. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS.
5. FIBERGLASS PIT LIDS WITH EA FRAME AND LIGHTWEIGHT
LOCKING LID OR APPROVED EQUIVALENT CONSTRUCTED
AND INSTALLED IN ACCORDANCE WITH AS3996 MAY BE

INSERT 730
USED INSTEAD OF CONCRETE.
6. PRECAST LINTEL TO MATCH REQUIRED KERB TYPE (SM2,B2) A A

900
7. REFER TO D 225 FOR MINIMUM HOUSE DRAIN CONNECTION.

150

TRANSITION
600mm
480

OF
150 600

BACK
B PLAN

100 THROAT

PRECAST LINTEL
(REFER NOTE 6) 50
100

195
150
DEPTH VARIES

100mm DIA. A.G. DRAINS


TO BE PLACED ON BOTH
20 SIDES
D
150

150 900 150 150 900 150

SECTION B-B SECTION A-A


ALL MEASUREMENTS IN MILLIMETRES

SIDE ENTRY PIT WITH LAST UPDATED JULY 2019


PRECAST LINTEL
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 235
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
A
500

230
ANCHOR BAR
12 DIAM x 150 MS
280

1500

750
30x30 CHAMFER ON TOP
FLANGE ONLY
SECTION A-A
125 x 65 13.4KG/M
CHANNEL
900

GRATE FRAME
HINGE PIN
64 x 64 x 10 MS ANGLE
16 DIAM MS ROD 15 LONG

ANCHOR BAR END BAR


12 DIAM x 150 MS 50 x16 MS

416
1500

1028
900

LOAD BARS
50 x 16 @ 69 CRS
A

GRATE DETAIL
(O/A SIZE 500 x 1000)

PLAN 524

GRATE REMOVED
GRATE FRAME
NOTES:

1. DETAILS FOR THE ABOVE GRATE HAVE BEEN DERIVED FROM THAT MANUFACTURED BY
'R & S GRATING'. SIMILAR BICYCLE SAFE GRATINGS FROM OTHER MANUFACTURERS MAY BE USED.
2. GRATE FRAME SHALL BE CONSTRUCTED FROM 64x64x10 MS ANGLE AND BE WELDED TO
25x65 13.4kg/m TF CHANNEL
3. GRATE UNITS SHALL BE MADE FROM 50x16 MS WITH 40x12 WEAVE BARS AND
CONTINUOUSLY WELDED ALL ROUND
4. GRATE AND FRAME SHALL BE HOT DIP GALVANISED TO AS 1650/1989 UNLESS SPECIFIED OTHERWISE.
5. PITS DEEPER THAN 1000 SHALL BE FITTED WITH STEP IRONS

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


GRATED SIDE ENTRY PIT
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 240
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
WEAVE STYLE GRATE TO BE USED
A
SEE NOTE 3

BACK OF KERB
PIT WIDTH 'W'

INVERT OF CHANNEL

LIP OF KERB

900
A CHANNEL DEPTH TRANSITION

PIT LENGTH 'L' GRATE & SURROUND TO BE CLASS D 'BICYCLE


SAFE' IN ACCORDANCE WITH AUSTRALIAN
STANDARDS.
PLAN

LINE OF KERB
REINFORCEMENT DETAILS
PIT LENGTH 'L' OR
REINFORCEMENT
CHANNEL INVERT 40mm WIDTH 'W'
DEEPER ACROSS UP TO 1200 SL92
THROAT OF PIT 1201 TO 1800 RL918

1801 TO 2400 RL1218

100
THROAT

REINFORCEMENT MESH TO
BE PLACED CENTRALLY.
PROVIDE BLOCKOUTS FOR
SUBSOIL DRAIN ADAPTOR ON
BOTH SIDES OF PIT
150

NOTES:
SEE NOTE 3 1. REFER TO R 150 FOR KERB DETAILS.
2. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS.
150 600 150 3. WHERE NO SUBSOIL DRAIN INSTALLED, OR WHERE
GRAVEL BACKFILL IS USED, OR WHERE EXPANSIVE
CLAYS ARE PRESENT; INSTALL 1m LONG SUBSOIL DRAIN
SECTION A-A AT THE BOTTOM OF THE PIT.
4. STEP IRONS REQUIRED FOR DEPTHS GREATER THAN
900mm. REFER D 200 FOR THE DETAIL DRAWING.

ALL MEASUREMENTS IN MILLIMETRES

GRATED SIDE ENTRY PIT INLET LAST UPDATED JULY 2019

WITH CONCRETE SURROUND


Banyule's Standard Drawings
A copy can be found on Banyule's website
D 245
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
WEAVE STYLE GRATE TO BE USED

ROLLOVER KERB
SEE NOTE 4

500

150
A A
1000
1300

900
150
NOTES:
500

1. REFER TO SD100 FR KERB DETAILS.


462 BACK OF KERB 2. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28
DAYS.
3. CLASS D LOADING IS REQUIRED FOR LID.
4. WHERE NO SUBSOIL DRAIN INSTALLED, OR
WHERE GRAVEL BACKFILL IS USED, OR WHERE
EXPANSIVE CLAYS ARE PRESENT; INSTALL 1m
PLAN LONG SUBSOIL DRAIN AT THE BOTTOM OF THE
PIT.
5. STEP IRONS REQUIRED FOR DEPTHS GREATER
THAN 900mm. REFER D 200 FOR THE DETAIL
DRAWING.

GRATE & SURROUND TO BE


CLASS 'D' ("BICYCLE SAFE") LINE OF KERB
PIT LID TO BE CONCRETE TYPE, OR
APPROVED EQUIVALENT MUST BE USED
150 435 226

462
600 MIN

300 Ø

PROVIDE 2 No 100mm STUBS


IN REAR WALL AS DIRECTED
150

APPROVED FCR BEDDING

100mm DIA. A.G. DRAINS TO BE


150

PLACED ON BOTH SIDES

SEE NOTE4
150 600 150

SECTION A-A

ALL MEASUREMENTS IN MILLIMETRES

GRATING PIT FOR SM2 LAST UPDATED JULY 2019


MODIFIED KERB & CHANNEL
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 250
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
WEAVE STYLE GRATE TO BE USED
INTERNAL OPENING OF
COVER 600mm x 350mm

KERB
150
GRATE & SURROUND TO BE
CLASS D 'BICYCLE SAFE' IN
ACCORDANCE WITH AUSTRALIAN
STANDARDS
COVER INSERT
730x480mm INSERT T30
900 ('L')

TAPER ON SIDE
LIFTING HOLE/S
TO BE PROVIDED
150

600mm TRANSITION
480

OF
SEE NOTE 2
150 600 ('W') 150
BACK

PLAN
LINE OF KERB
CHANNEL TO BE
TRANSITIONED
100 THROAT 0.60m ON BOTH
SIDES OF GRATING
STAGE TWO

PIT TO BE CONSTRUCTED IN
TWO STAGES
STAGE 2 - TOP 500mm OF PIT
IN CONJUNCTION WITH KERB
AND CHANNEL 300
50
STAGE ONE

150

SEE NOTE 2 150 600 ('W') 150 600

SECTION A-A

NOTES:

1. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS


2. WHERE NO SUBSOIL DRAIN INSTALLED, OR WHERE GRAVEL
BACKFILL IS USED, OR WHERE EXPANSIVE CLAYS ARE PRESENT;
INSTALL 1m LONG SUBSOIL DRAIN AT THE BOTTOM OF THE PIT.
3. STEP IRONS ARE REQUIRED FOR DEPTHS GREATER THAN 900mm.
REFER D 200 FOR THE DETAIL DRAWING.

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


SIDE ENTRY PIT WITH GRATING
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 255
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
WEAVE STYLE GRATE TO BE USED

600 450 APPROX.


175
GRATE TO BE CLASS B
"BICYCLE SAFE" IN ACCORDANCE A
WITH AUSTRALIAN STANDARDS
R2.0
0 R1
R1. .0

450 APPROX.

610
0 R2.0
230 R2.

SPOONDRAIN SPOONDRAIN

100 115 CONCRETE PATH


CLEAR OPENING
MATCH EDGE PATH
30mm
A

PLAN

GRATE TO BE CLASS B "BICYCLE SAFE" IN


ACCORDANCE WITH
AUSTRALIAN STANDARDS
40
NATUR 10
E STRIP
100

FOOTPATH

EDGE PATH

DEPTH VARIES

100 370 (MIN) 100

NOTES: SECTION A-A


1. EDGE CONCRETE AROUND PERIMETER OF GRATE.
2. TOP OF GRATE 50mm BELOW EDGE OF PATH.
3. DO NOT BOND GRATE TO TO CONCRETE TO ALLOW EASY ACCESS TO PIT.
4. CONCRETE TO BE SMOOTH TROWELLED FINISH.
5. GRATE FRAME TO BE OILED IF INSTALLED IN WET CONCRETE.
6. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


SPOON PIT WITH GRATING
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 260
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
A A

PIT CHAMBER
SETOUT POINT

INVERT

LIP
BACK OF KERB
PLAN
(COVERS REMOVED)

COVER EXTENSION
AS SPECIFIED

THROAT
100 MIN

IN.
E 1:4 M
SLOP
ALTERNATE ARRANGEMENT
FOR ROLLOVER KERB
150
SEE NOTE 2
SERVICE CONDUIT
MIN. 150 CLEARANCE ALL ROUND

NOTES:
SECTION A-A
1. FOR STANDARD COVER EXTENSIONS REFER VICROADS STANDARD DRAWING
SD1051 ISSUE C
2. Y12 DEFORMED STARTER BARS TO BE PROVIDED WHERE EXTENDED THROAT
IS TO BE CONSTRUCTED TO AN EXISTING PIT.

ALL MEASUREMENTS IN MILLIMETRES

EXTENDED THROAT SIDE LAST UPDATED JULY 2019

ENTRY PIT
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 265
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
300X300
MEDIUM DUTY
HINGED GRATE
AND FRAME
150 DIA. UPVC
TO NEAREST PIT NATURE STRIP A 100 THICK
AT MIN 1 IN 40 CONCRETE
GRADE APRON

75 THICK
CONCRETE
WING

VEHICLE
CROSSING

FOOTPATH 150 THICK


CONCRETE A
INFILL

PLAN
NATURE STR
IP
FOOTPATH
50

250
1

0
1:

15

100

100 300 100

SECTION A-A
NOTES:

1. GRATE & FRAME TO BE HOT DIPPED GALVANISED AFTER WELDING.


2. GRATED PIT IS NOT TO BE LOCATED IN PEDESTRIAN/CYCLE TRAFFIC
AREAS
3. HEAL PROOF GRATE TO BE USED FOR PEDESTRIAN TRAFFIC, OTHERWISE
WEAVE GRATE IS REQUIRED

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


FOOTPATH GRATED PIT
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 270
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
CHANNEL FLOW
DIRECTION OF
NOTES:

150
1. GRATE & SIDE ENTRY PIT FOR PIPE DIA.
UP TO 450mm
2. STEP IRONS TO BE PROVIDED IN ALL
LINE OF LIP OF KERB CHANNEL

100mm
PITS GREATER THAN 1000mm IN DEPTH

LINE OF BACK OF KERB


PVC 3. PROVIDE 100mm PVC STUB IN BOTH PIT
STUBS WALLS 700mm BELOW SURFACE FOR AG
DRAIN (ON BOTH ENDS OF PIT AT LOW

900
POINT).
4. PROVIDE 2 x 100mm PVC STUBS IN REAR
WALL OF PIT 500mm BELOW SURFACE
FOR HOUSE DRAIN CONNECTIONS AS
FOR DIRECTED.
DETAILS OF 5. CONCRETE STRENGTH F'C = 25MPa.
GRATE &
FRAME SEE

150
D 240

PLAN
PRECAST LINTEL TO D 220
PIT LID AS PER TO D 205
600
80

100

FOR DETAILS OF
400
GRATE
450
700

& FRAME
SEE D 240
250
300
100

100mm PVC
150

STUBS

150
STEP IRONS TO BE
INSTALLED AS PER D 200
D

3:1
50mm COMPACTED 3:1

DEPTH OF CLASS 3
D/2

FCR
SECTION A-A
150

630 150 600 150

ALL MEASUREMENTS IN MILLIMETRES

COMBINATION GRATE & SIDE LAST UPDATED JULY 2019

ENTRY PIT
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 275
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
SUITABLE FIBRE GLASS PIT COVER OR GATIC LID TO BE
DETERMINED BY AUTHORISED OFFICER LINE OF KERB
150 150

THROAT
100 MIN

OF PAVEMENT
MIN DEPTH TO
75
1000

UNDERSIDE
120 DIA HOLE IN
SIDE WALLS TO 20
50 MIN 50 MIN
'D'

ACCOMMODATE
PAVEMENT DRAINS
IN BOTH SIDES

Ø
150

PRECAST PIT
150 'W' 150
600MIN

PITS UP TO 3600mm DEPTH

150
MIN
300

450

NOTES:
300
MIN
1. MINIMUM PIT SIZES:
450
PIPE DIAMETER
BASE DIMENSIONS 'W'
JP SEP
250 UP TO 450Ø UP TO 450Ø 600

450Ø & UPWARDS 450Ø & UPWARDS 900


MIN
300

2. PIPES GREATER THAN 450mm DIA. MAY REQUIRE HAUNCHING. REFER TO D 285.
600

3. FOR DETAILS OF SPECIFIC PITS, REFER TO PIT SCHEDULE.


4. PIT REINFORCEMENT SHALL HAVE 300mm MIN LAPS. CLEAR COVER TO BE 50mm
MIN. CORNER RETURN REINFORCEMENT MAY BE FABRIC OR EQUIVALENT BARS.
300 5. FOR TOP OF PIT DETAILS, REFER TO PIT SCHEDULE AND RELEVANT STANDARD
MIN DRAWINGS.
6. PRECAST PITS WITH THINNER WALLS AND LESS STEEL MAY BE ACCEPTED
600 WHERE THE MANUFACTURER CAN DEMONSTRATE THAT THE PITS HAVE
ADEQUATE CAPACITY TO SUPPORT A COMBINATION OF THE FOLLOWING LOADS:
- EARTH PRESSURE WITH 210 kN SURCHARGE
PLAN VIEW
- HYDROSTATIC PRESSURE
- COMPACTION PRESSURE (25 kPa MIN)
CORNER DETAILS - VERTICAL LOAD 210 kN
7. SUBSURFACE DRAIN HOLES TO BE SEALED IF NOT USED.
REINFORCEMENT DETAILS 8. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS.
9. EXCAVATED MATERIAL SHOULD NOT BE USED AROUND PIT SURROUND. 3%
PIT LENGTH 'L' OR
WIDTH 'W'
REINFORCEMENT CEMENT STABLISER MUST BE USED.
10. STEP IRONS ARE REQUIRED FOR ALL PITS WHICH ARE ≥ 1M IN DEPTH
UP TO 1200 SL92

1201 TO 1800 RL918

1801 TO 2400 RL1218

ALL MEASUREMENTS IN MILLIMETRES

UNHAUNCHED PITS LAST UPDATED JULY 2019


(SIDE ENTRY)
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 280
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
SUITABLE FIBRE GLASS PIT COVER OR GATIC LID TO BE
DETERMINED BY AUTHORISED OFFICER
150 600 150

LINE OF KERB

75 75
THROAT 110

OF PAVEMENT
MIN DEPTH TO
UNDERSIDE
225
'D'

50 MIN 50 MIN

20

'BH'
Ø

150 120 DIA HOLE IN SIDE WALLS TO


150 'BW' 150 ACCOMMODATE PAVEMENT
DRAINS IN BOTH SIDES.

PITS UP TO 3600mm DEPTH PRECAST PIT

150 NOTES:
300 1. PIPES LESS THAN 525mm DIA. MAY NOT REQUIRE HAUNCHING. REFER D 280.
MIN 2. PITS WITH HAUNCHING IN TWO DIRECTIONS REQUIRE SPECIAL STRUCTURAL DESIGN.
3. FOR DETAILS OF SPECIFIC PITS, REFER TO PIT SCHEDULE.
4. PIT REINFORCEMENT SHALL HAVE 300mm MIN LAPS. CLEAR COVER TO BE 50mm MIN.
CORNER RETURN REINFORCEMENT MAY BE FABRIC OR EQUIVALENT BARS.
450

5. FOR TOP OF PIT DETAILS, REFER TO PIT SCHEDULE AND RELEVANT STANDARD DRAWINGS.
6. PRECAST PITS WITH THINNER WALLS AND LESS STEEL MAY BE ACCEPTED WHERE THE
MANUFACTURER CAN DEMONSTRATE THAT THE PITS HAVE ADEQUATE CAPACITY TO
300
SUPPORT A COMBINATION OF THE FOLLOWING LOADS:
MIN
- EARTH PRESSURE WITH 210kN SURCHARGE
450 - HYDROSTATIC PRESSURE
- COMPACTION PRESSURE (25 kPa MIN)
- VERTICAL LOAD 210 kN
7. SUBSURFACE DRAIN HOLES TO BE SEALED IF NOT USED.
250
300 8. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS.
MIN 9. STEP IRONS REQUIRED FOR DEPTHS GREATER THAN 900mm. REFER D 200 FOR THE DETAIL
DRAWING.
600

300 PIT SIZING


MIN REINFORCEMENT DETAILS
'BW' & 'BH' 'Ø'
PIT BASE LENGTH 'BL' (mm) (mm)
600 REINFORCEMENT
OR BASE WIDTH 'BW' 900 525
UP TO 1200 SL92 " 600
" 675
PLAN VIEW 1201 TO 1800 RL918
" 750
CORNER DETAILS 1801 TO 2400 RL1218 " 825
1200 900
" 975
" 1050
" 1125
1500 1200

ALL MEASUREMENTS IN MILLIMETRES

HAUNCHED PITS LAST UPDATED JULY 2019


(SIDE ENTRY)
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 285
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
T1

H1
L

H2
PLAN

T2

6.0
SECTION
RE ULD BY C
SH CASE

5.4
INF
A
O
OR E DE SE B

4.8
DEPTH (H1 AND H2), METRES

CE
B
225

DC
200

4.2
175

ON ED O
SIG ASI
A
150

CR

3.6
N
mm
(T1

ET N
WA T2),

E
AN

3.0
D
LL
TH ILLIM

2.7
ICK
M
NE TRE

2.4
SS
E

2.1
S

1.8

1.5
0.45 0.6 0.9 1.2 1.5

PIT LENGTH(L), METRES

ALL MEASUREMENTS IN MILLIMETRES

MIN. WALL THICKNESS FOR REINFORCEMENT LAST UPDATED JULY 2019


IN MASS CONCRETE PITS (CAST IN-SITU)

Banyule's Standard Drawings


A copy can be found on Banyule's website
D 290
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
FINISHED SURFACE LEVEL

450 150 150 450

150
100

REINFORCEMENT DETAILS
PIT LENGTH 'L' OR
REINFORCEMENT
WIDTH 'W'
UP TO 1200 SL92
REINFORCEMENT MESH
1201 TO 1800 RL918 TO BE PLACED
1801 TO 2400 RL1218 CENTRALLY.

150

APPROVED FCR
BEDDING
150 PIT WIDTH 'W' 150
REFER PIT SCHEDULE
A
SECTION A-A

WEAVE STYLE GRATE TO BE USED

B FLOW B
'W'

NOTES:
1. CONCRETE STRENGTH F'C = 25MPa.
(MIN) AT 28 DAYS.

'L'

APPROVED GRATE & FRAME TO BE


A INSTALLED TO MANUFACTURERS
SPECIFICATIONS.
REFER TO PIT SCHEDULE FOR DETAILS
PLAN 100
NOT TO SCALE
25
NOTES:
FLOW
1. HEAVY DUTY COVERS TO BE USED WHEN SUBJECT TO
TRAFFICABLE LOADS (AS3996 CLASS D - 210kN) OR
APPROVED EQUIVALENT.
MEDIUM DUTY COVERS TO BE USED IN OFF ROAD USE
(AS3996 CLASS B - 80kN) OR APPROVED EQUIVALENT.
2. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS.
ALTERNATIVE
PROVIDING FOR SECTION B-B
FLOWS IN BOTH
DIRECTIONS

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


DEPRESSED GRATED PIT
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 295
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
150 900 150

CONCRETE COVER WITH APPROVED LIFTING


B ANCHORS & F81 MESH PLACED CENTRALLY.
GATIC COVER OR APPROVED EQUIVALENT TO
BE USED IN ROAD RESERVES OR OPENING ON
BOTH SIDES.

SEE NOTE 4
REINFORCEMENT DETAILS
PIT LENGTH 'L' OR
REINFORCEMENT
A A WIDTH 'W'
UP TO 1200 SL92

1201 TO 1800 RL918

1801 TO 2400 RL1218

40mm N.B.
GALVANISED NOTES:
HEAVY WEIGHT 1. PLACEMENT OF PIT WITHIN ROAD RESERVE /
B PIPE CAST INTO MUNICIPAL RESERVE SUBJECT TO COUNCIL
PIT WALLS APPROVAL.
75 MIN INLET TO BE FULL LENGTH 2. REFER TO PIT SCHEDULE FOR CORRECT PIT
ORIENTATION.
3. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28
PLAN DAYS.
NOT TO SCALE 4. WHERE NO SUBSOIL DRAIN INSTALLED, OR WHERE
GRAVEL BACKFILL IS USED, OR WHERE EXPANSIVE
CLAYS ARE PRESENT; INSTALL 1m LONG SUBSOIL
DRAIN AT THE BOTTOM OF THE PIT.

25x25mm
CHAMFER
1 2
in
1 1/ 'W'+300
1/ 1
2 in
1
125

40mm N.B.
GALVANISED
HEAVY WEIGHT
300

PIPE CAST INTO PIT


150

WALLS

100x100 CHAMFER PROVIDE BLOCKOUTS


R 150
FOR SUBSOIL DRAIN
ADAPTOR ON BOTH
SIDES OF PIT

REINFORCEMENT
SHAPE BASE MESH TO BE
AS SHOWN PLACED
CENTRALLY.
150

SEE NOTE 4

150 900 150 150 600 150

SECTION A-A SECTION B-B

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


INLET CATCH PIT
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 300
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
A
150 1900 150
FIBRE GLASS LIDS TO BE
INSTALLED TO MANUFACTURERS
SPECIFICATIONS.

SEE NOTE 3

EXPANSION JOINTS EXPANSION JOINTS

1000 A 1000
CHANNEL DEPTH TRANSITION CHANNEL DEPTH TRANSITION
PLAN
NOT TO SCALE

LINE OF KERB

450 BACK OF KERB 25 MAX MORTAR


(LINE OF SET-OUT) PACKING

CHANNEL INVERT 40mm DEEPER


ACROSS THROAT OF PIT

180
110
PRE-CAST LINTEL TO SUIT THROAT
75

PROVIDE BLOCKOUTS FOR SUBSOIL


DRAIN ADAPTOR ON BOTH SIDES OF PIT
150

SEE NOTE 3

150 600 150

SECTION A-A

REINFORCEMENT DETAILS NOTES:


PIT LENGTH 'L' OR
REINFORCEMENT 1. REFER TO SD100 FR KERB DETAILS.
WIDTH 'W'
2. CONCRETE STRENGTH F'C = 25MPa. (MIN) AT 28 DAYS.
UP TO 1200 SL92
3. WHERE NO SUBSOIL DRAIN INSTALLED, OR WHERE GRAVEL BACKFILL IS
1201 TO 1800 RL918 USED, OR WHERE EXPANSIVE CLAYS ARE PRESENT; INSTALL 1m LONG
1801 TO 2400 RL1218
SUBSOIL DRAIN AT THE BOTTOM OF THE PIT.

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


DOUBLE SIDE ENTRY PITS
Banyule's Standard Drawings
A copy can be found on Banyule's website
D 305
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
ANCILLARY
This page was intentionally left blank
Retaining walls
This page was intentionally left blank
FORM CAVITY FOR FENCE POSTS AS
REQUIRED AND AS DIRECTED
300

FOOTPATH OR LAYER OF LOAM

RAKE ON BACK OF WALL


VARIES WITH BASE
WIDTH OF WALL

BACKFILL WITH 20mm ONE


SIZE SCREENINGS OR
BOUNDARY LINE OTHER APPROVED POROUS
MATERIAL

WALL HEIGHT
WRAP BACKFILL
SCREENINGS IN GEOFABRIC

GEOFABRIC PLACED TO
PREVENT SCREENINGS
ENTERING 50mm
WEEPHOLE

SURFACE
FOOTING
DEPTH

EXISTING 300 MIN. BASE FOUNDATION TO BE


APPROVED BY ENGINEER BEFORE
PROCEEDING FURTHER
BASE WIDTH
50mm PVC PIPE WEEP HOLE
AT 5m SPACINGS

NOTE: FOR WALL HEIGHTS, FOOTING DEPTH AND BASE


WIDTHS NOT SHOWN ON TABLE SEE FIG 1.
WALL FOOTING BASE
HEIGHT (m) DEPTH (m) WIDTH (m)
1.2 0.48 0.72
1.8 0.68 1.08
2.4 0.85 1.45
3.0 1.00 1.80

ALL MEASUREMENTS IN MILLIMETRES

LOW SIDE STONE RETAINING LAST UPDATED JULY 2019

WALL
Banyule's Standard Drawings
A copy can be found on Banyule's website
A 100
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
FORM CAVITY OF SUITABLE DIMENSION
FOR STEEL POLE OR PINE LOG AS
300 REQUIRED AND AS DIRECTED BY THE
SUPERVISING ENGINEER.

BACK FILL WITH 20mm


ONE SIZE SCREENINGS
OR OTHER APPROVED
POROUS MATERIAL * SLOPE VARIES FOR HEIGHTS OVER 1.7m

WALL HEIGHT NOTE: FOR WALL HEIGHTS 1.7m AND


OVER REFER TO TABLE 1 FOR BASE
150
WIDTHS AND FOOTING DEPTHS
BACK FILL
SCREENINGS TO
BE WRAPPED WITH
GEOFABRIC
FORM A LARGE LETTER "O"
(AT LEAST 75mm HIGH) IN
CONCRETE OF KERB
WHEREVER A DRAIN
FOOTPATH CONNECTION TO THE PIPE
DRAIN OR AG DRAIN IS
MADE
300 MIN.

50Min. 150Max.
150
Ø100mm 1 in 40 Min.

INVERT OF Ø100mm
AG PIPE COUNCIL APPROVED
SADDLE PIPE DRAIN

NOTE:

STONE SHALL BE CLEAN SOUND HARD BLUESTONE OR OTHER APPROVED HARD STONE IN SELECTED COLOUR
TONINGS AND SHALL BE BUILT IN CONCRETE AS SPECIFIED. ALL SPACES BETWEEN STONES BEING COMPLETELY
FILLED JOINTS ON THE EXPOSED FACE SHALL BE POINTED UP WITH MORTAR CONSISTING OF 1 PART CEMENT AND 5
PARTS APPR. SAND AND SHALL BE LEFT GENERALLY RECESSED BELOW THE FACE OF THE WALL AS DIRECTED

TABLE 1
FOR WALL HEIGHTS 1.7m AND OVER

WALL FOOTING BASE WALL FOOTING BASE


HEIGHT (m) DEPTH (m) WIDTH (m) HEIGHT (m) DEPTH (m) WIDTH (m)
1.7 0.30 0.79 2.4 0.45 1.17
1.8 0.45 0.86 2.5 0.45 1.23
1.9 0.45 0.91 2.6 0.45 1.27
2.0 0.45 0.96 2.7 0.45 1.31
2.1 0.45 1.01 2.8 0.60 1.36
2.2 0.45 1.06 2.9 0.60 1.41
2.3 0.45 1.10 3.0 0.60 1.45

ALL MEASUREMENTS IN MILLIMETRES

HIGH SIDE STONE RETAINING LAST UPDATED JULY 2019

WALL
Banyule's Standard Drawings
A copy can be found on Banyule's website
A 105
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
20mm CRUSHED ROCK NO FINES
DRAINAGE LAYER WITH Ø100mm
PVC "AG" DRAIN AT BASE OF WALL.

1.0
SLOPE FACE OF WALL
BACK
AX
1:4 M
100UC14 HOT-DIP GALVANIZED
STEEL SOLDIERS AT 2400
CENTRES,

HEIGHT OF SOIL
RETAINED 'H'
200X75 F7 HARDWOOD
EXISTING

(1000 MAX)
TIMBER OR CONCRETE
SLEEPERS SURFACE
PROFILE

DEPTH = H/2, MIN 300mm

Ø350mm 25MPa
CONCRETE FOOTING

TYPICAL SECTION

ALL MEASUREMENTS IN MILLIMETRES

TIMBER SLEEPER RETAINING LAST UPDATED JULY 2019

WALL
Banyule's Standard Drawings
A copy can be found on Banyule's website
A 110
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
This page was intentionally left blank
Reo Detail for Concrete
This page was intentionally left blank
12
2 mm BELOW SURFACE
SEALANT MATERIAL

15
SAWN JOINT FACE

SLAB DEPTH/4
TAPE BOND-BREAKER BETWEEN
SEALANT & CONCRETE

INITIAL SAW CUT

INDUCED CRACK

SEALANT DETAIL TYPE 1

12 2 mm BELOW SURFACE
SEALANT MATERIAL

SAWN JOINT FACE


SLAB DEPTH/4

25

ROPE OR ROD BACK-UP MATERIAL

INITIAL SAW CUT

INDUCED CRACK

SEALANT DETAIL TYPE 2

ALL MEASUREMENTS IN MILLIMETRES

REINFORCED CONCRETE LAST UPDATED JULY 2019


PAVEMENT SEALANT DETAILS
Banyule's Standard Drawings
A copy can be found on Banyule's website
A 150
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
TJ

TJ
IJ IJ

TJ
TJ
TJ TJ
IJ

IJ

TJ
IJ
TJ
IJ
TJ

TJ

TJ

TJ
TJ
PIT / ACCESS HOLE AT EDGE (PLAN) PIT / ACCESS HOLE NOT AT EDGE (PLAN)

LEGEND:

ISOLATION JOINT

TOOLED JOINTS

10mm THICK BITUMEN 75


IMPREGNATED FIBREBOARD OR AN
1
APPROVED EQUIVALENT FILLER -

EXISTING STRUCTURE / SLAB


SLAB REINFORCEMENT

D+50
D
SLAB EDGE THICKENING

10 100 300

TYPICAL SECTION

TOP 10MM TO BE FILLED WITH APPROVED POURING GRADE


SEALANT TO MANUFACTURER'S SPECIFICATIONS

10

10MM THICK BITUMEN IMPREGNATED FIBREBOARD


OR AN APPROVED EQUIVALENT FILLER

NOTES: DETAIL 1
NOT TO SCALE -
1. EXPANSION FOAM TO BE USED AT PERIMETER
OF ANY PIT
2. ALL SQUARE AND RECTANGULAR PIT/ACCESS
HOLES MUST HAVE TOOL JOINTS AT 45 DEGREE
ANGLE TO THE HORIZONTAL OR VERTICAL
3. 'D' DENOTES DEPTH OF PAVEMENT

ALL MEASUREMENTS IN MILLIMETRES

REINFORCED CONCRETE LAST UPDATED JULY 2019


PAVEMENT ISOLATION JOINT
Banyule's Standard Drawings
A copy can be found on Banyule's website
A 155
www.banyule.vic.gov.au
Approved by: James Kelly
Manager Delivery & Assets
NOT TO SCALE
F72 REINFORCEMENT
AS PER R 260
FUTURE SLAB

75

D
D/2
400

VERTICAL FACE TO BE FORMED


WITH AN APPROVED METHOD

TYPICAL FUTURE CONSTRUCTION JOINT

5 x 40mm DEEP SAW CUT TO BE FILLED WITH APPROVED


POURING GRADE SEALANT TO MANUFACTURER'S
SPECIFICATIONS. TOOL SEALANT TO FORM 5MM RECESS.
SEALANT COLOUR TO MATCH PAVEMENT SURROUND

CONTINUOUS SLAB REINFORCEMENT

INDUCED CRACK

TYPICAL SAWN CONTRACTION JOINT

* 'D' DENOTES DEPTH OF FOOTPATH

ALL MEASUREMENTS IN MILLIMETRES

REINFORCED CONCRETE LAST UPDATED JULY 2019


PAVEMENT JOINT DETAIL
Banyule's Standard Drawings
A copy can be found on Banyule's website
A 160
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
This page was intentionally left blank
Other
This page was intentionally left blank
3050 TYPICAL

CENTRAL INVERT
(Fence line)

(Fence line)
Building line

Building line
50 MIN.
1 in 30 1 in 30

10mm FOAM JOINT ON BOTH 10mm FOAM JOINT ON BOTH SIDES


SIDES OF LANEWAY
600 MIN.
OF LANEWAY

200mm THICK MIN. 32MPa CONCRETE


REINFORCED WITH SL82 MESH CENTRALLY LOCATED ON
WHERE PIPE IS TO BE PROVIDED, BACK FILL TRENCH 100MM HIGH BAR CHAIRS
WITH FINE CRUSH ROCKS, AS PER BCC STD DWG D 100

MIN.50mm THICK COMPACTED DEPTH Class 2 FCR BEDDING


PIPE

APPROVED SUBGRADE MIN. 50mm TO 150mm SUBJECT


REFER TO BCC STD DWG B023 FOR PIT SPECIFICATION TO SOIL TEST
AND PIPE SIZE

SAWCUT 3mm WIDE x 30mm DEEP


FILLED WITH APPROVED SEALANT
BROOM FINISH COLOURED PAVING
200

50
SAWCUT JOINT
PLACE AT MAXIMUM 2m SPACING
SAWCUT TO BE MADE 18-24 HOURS AFTER POURING

RESERVOIR 30mm DEEP


15mm WIDE FILLED 75 75
WITH APPROVED SEALANT
BOND BREAKER
200

50

DOWEL BARS 20mm DIA.


@ 300mm CTRS x 450mm LONG

CONSTRUCTION JOINT
PLACE AT LOCATIONS MARKED ON PLANS PLUS TRANSVERSE JOINTS
MAXIMUM OF 15m SPACING

15
APPROVED SEALANT
200

75 75
50
50

350 350
EXPANDING CORK

EXPANSION & ISOLATION JOINT


PLACE AROUND PITS & ALONG ALL EDGES OF STRUCTURES

NOTES:

1. CONCRETE STRENGTH SHOULD BE MIN. 25MPa TO 32MPa, SEASON DEPENDENT, SUBJECT TO BCC APPROVAL
2. SUBGRADE TO BE GRADED AND ROLLED TO THE SATISFACTION OF COUNCIL'S SUPERINTENDENT PRIOR LAYING
CONCRETE
3. PREVAILING SUGARED CONDITIONS DETERMENT THICKENS OF BEDDING, SUBJECT TO BCC APPROVAL
4. EXPANSION JOINTS TO BE EVERY 12 METERS AND AROUND POLES, MANEHOLES AND OTHER SERVICE AUTHORITY
FIXTURES
5. CHAIRS TO BE USED TO SUPPORT F82x2 REINFORCEMENT MESH
6. SURFACE FINISH IS TO BE A ROUGH BROOM FINISH
7. PIT COVERS TO BE HEAVY DUTY GATIC LIDS OR BIKE SAFE GRATED COVERS, SUBJECT TO BCC APPROVAL
8. TRAFFIC SIGNS AND LINEMARKING REQUIRED TO BE APPROVED BY BCC TRANSPORT UNIT
9. MAINTENANCE PERIOD OF 12 MONTHS IS REQUIRED FROM COMPLETION OF WORKS

ALL MEASUREMENTS IN MILLIMETRES

LAST UPDATED JULY 2019


LANEWAY TYPICAL SECTION
Banyule's Standard Drawings
A copy can be found on Banyule's website
A 200
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
ASPHALT SURFACE SHOULD BE REINSTATED
TO IT'S ORIGINAL DEPTH (LIKE FOR LIKE)

SURFACE TO MATCH EXISTING, INCLUDING DEPTH


WEARING SURFACE
CUT WEARING SURFACE
WITH SAW TO FORM A
STRAIGHT EDGE

300mm COMPACTED DEPTH 150mm COMPACTED DEPTH


300

300
CLASS 2 F.C.R. IN 2 x 150mm CLASS 3 F.C.R.
LAYERS. TOP (BASE)
COMPACTED TO 98% MODIFIED
DENSITY RATIO.
LOWER (SUB BASE) LAYER
COMPACTED TO 98% MODIFIED
DENSITY RATIO.
VARIES (MIN. 150mm)

VARIES (MIN. 150mm)


CLASS 2 F.C.R. (OR APPROVED
EQUIVALENT MATERIAL). APPROVED GRANULAR
BACKFILL AND COMPACTED BACKFILL RAMMED OR
MECHANICALLY IN 150mm ROLLED IN 150mm LAYERS
LAYERS USING VIBRATING TO 98% MODIFIED DENSITY
RAMMER TO 98% MODIFIED RATIO.
DENSITY RATIO.

AUTHORITY'S MARKER TAPE AUTHORITY'S MARKER TAPE


150

150
AUTHORITY'S SERVICE ZONE AUTHORITY'S SERVICE ZONE
INCLUDING ATTACHMENTS INCLUDING ATTACHMENTS
AND APPENDAGES AND APPENDAGES

GRANULAR BEDDING MATERIAL GRANULAR BEDDING MATERIAL


INDEX LESS THAN 3 INDEX LESS THAN 3

ANY UNSUITABLE MATERIAL ANY UNSUITABLE MATERIAL


TO BE REMOVED FROM FLOOR TO BE REMOVED FROM FLOOR
OF TRENCH OF TRENCH

TRENCHES UNDER ROADS TRENCHES UNDER FOOTPATHS

RE-SEED AND LEVEL TO


MATCH EXISTING

COUNCIL APPROVED
300

NOTES:
TOPSOIL AND SEEDED.
1. COMPULSORY MEASURES FOR THE PROTECTION OF TRENCHES
1.5 OR MORE IN DEPTH ARE TO COMPLY WITH THE
REQUIREMENTS OF THE MINES ACT 1958 & OH&S ACT 1985.
2. BITUMEN ROAD SURFACE SHALL BE CUT WITH A APPROPRIATE
EQUIPMENT (ROAD SAW, DEMO SAW).
3. UNDER THE ROAD MANAGEMENT ACT 2004 THESE WORKS SHALL
BE GUARANTEED FOR 12 MONTHS.
4. ALL WORKS TO BE COMPACTED TO THE SATISFACTION OF
VARIES (MIN. 150mm)

COUNCIL

AUTHORITY'S MARKER TAPE


150

AUTHORITY'S SERVICE ZONE


INCLUDING ATTACHMENTS
AND APPENDAGES

GRANULAR BEDDING MATERIAL


INDEX LESS THAN 3

ANY UNSUITABLE MATERIAL


TO BE REMOVED FROM FLOOR
OF TRENCH

TRENCHES UNDER SWALES


ALL MEASUREMENTS IN MILLIMETRES

TRENCHING BACKFILL LAST UPDATED JULY 2019


(TRENCHES WITHIN 1m OF COUNCIL ASSETS)

Banyule's Standard Drawings


A copy can be found on Banyule's website
A 205
www.banyule.vic.gov.au
Approved by: James Kelly NOT TO SCALE
Manager Delivery & Assets
This page was intentionally left blank