Beruflich Dokumente
Kultur Dokumente
1
Frosio course hand-out: Section 15 Tech data & calculations
Technical Data
• Most of the product data we need
for carrying out inspections and for
carrying out necessary calculations
can be found in the Technical Data
Sheets (TDS) and/or in the Material
Safety Data Sheets (MSDS).
2
Frosio course hand-out: Section 15 Tech data & calculations
CALCULATIONS
• Can you calculate how high wet thickness to apply
of a product with 65% solid content that has been
diluted 15%, in order to achieve a dry film
thickness of 60 microns, and how much will the
total paint and thinner cost should when applying
two such coats on the outside of a cylindrical 8
meter high tank with diameter 12 meter, when the
loss is estimated to be 35% and the purchase price
is $8.25 for the paint and $2.90 for the thinner?
3
Frosio course hand-out: Section 15 Tech data & calculations
Calculations : Paint
Abbreviations
• RATIO: 1 : 1 : 1000
4
Frosio course hand-out: Section 15 Tech data & calculations
WFT x % VS
Formula: DFT = 100
Example:
WFT = 250 Pm
% VS = 50 %
250 x 50
DFT = = 125 Pm
100
DFT x 100 %
Formula : WFT = % VS
Example:
DFT = 100 Pm
% VS = 65 %
5
Frosio course hand-out: Section 15 Tech data & calculations
Example:
DFT = 100 Pm
% VS = 65 %
Added thinner = 20 %
6
Frosio course hand-out: Section 15 Tech data & calculations
% VS x 10
Formula: = m2/litre
DFT
65 x 10
Spreading rate: = 6,5m2/litre
100
Paint DFT % VS
Epoxy mastic 200 microns 85 %
Polyurethane topcoat 50 “ 50 %
7
Frosio course hand-out: Section 15 Tech data & calculations
2
Formula: Area, m x DFT
10 x % VS
500 x 50
Polyurethane topcoat = 50,0 litre
10 x 50
500 x 200
Epoxy mastic 10 x 85 x 0,6 = 196 litre
8
Frosio course hand-out: Section 15 Tech data & calculations
Dead Volume
Increases the Volume of Paint Required
2
Total Dead volume, litre = Area (m ) x DV x 100
% VS x LF
9
Frosio course hand-out: Section 15 Tech data & calculations
500 x 200
Epoxy mastic (EM) = 196 litre (EM)
10 x 85 x 0,6
10