Sie sind auf Seite 1von 7

Outdoor Emergency Lighting

GARDCO
LIGHTING
EMERGENCY OUTDOOR LIGHTING– EMERGENCY OUTDOOR LIGHTING–
NOW REQUIRED ARCHITECTURAL SOLUTIONS
Typically no provisions at all are made for outdoor emergency lighting. A common solution is a wet location, "frog
The need for outdoor emergency lighting isn't always readily apparent. Common sense however would suggest that
eyes" type emergency luminaire which invariably detracts from the aesthetics of the site. Gardco offers a variety of
many areas requiring outdoor lighting for safety and security might also require emergency lighting in the event of a
architectural emergency outdoor lighting solutions which are discretely housed in the standard luminaires thereby
power outage. Moreover, there are at least three compelling reasons to include outdoor emergency lighting in any
preserving the intent of the architectural design.
outdoor lighting design.

Safety and Security Building Mounted Emergency Luminaires


One of the most natural human conditions is fear of
the dark in unfamiliar circumstances. The potential
for tripping over a curb, an accident, becoming a
crime victim, or simply being unable to locate one's
car will produce considerable anxiety in most people.
In a power outage there is a strong possibility that
there will be no visible ambient light from adjacent
street or building lighting. In the event of heavy cloud
cover, even moonlight or starlight may be non-
existent. It is precisely these frequently occurring
conditions which prescribe the need for emergency
outdoor lighting. The elegant 94 Line of recessed The Gardco 100 Line sconces have The Gardco GP1 is a cutoff luminaire
architectural step and aisle lights become the industry's choice for designed specifically for parking
offers pure, contemporary forms. The architectural, building mounted cutoff garage lighting. Recognizing that a
Liability 94EM series incorporates an integral
battery backup creating a remarkably
luminaires. The standard luminaires are
available in ten shapes, three sizes and
parking garage may be one of the
most dangerous environments during
As in most areas of litigation, the number of outdoor unobtrusive emergency lighting with lamp offerings from 26W compact a power outage, emergency quartz
lighting related liability settlements and the size of system. Furthermore, this recessed fluorescent to 400W HID. Emergency lampholders are offered as a
those settlements are increasing dramatically. With luminaire complies with the ADA units are offered with either (2) 26W or standard option on all Gardco parking
affordable emergency outdoor lighting solutions now requirement for maximum protrusion. (1) 42W compact fluorescent lamps. garage luminaires.
readily available, juries will be increasingly willing to
hold property owners responsible for outdoor
accidents and crimes occurring during power Bollards and Pole Mounted Products
outages. The enormous cost of legal defense in these
cases typically drives the overall liability costs even
higher. Even the settlement of a single minor injury
suit may be much greater than the entire cost of a
comprehensive outdoor emergency lighting system.

Code Requirements

Most local ordinances require compliance with the National Electric Code and the A very subtle method for pathway Where wider area coverage is For confined parking areas such
Life Safety Code of the National Fire Protection Association. The 2000 NFPA Life lighting is the 943B unidirectional desired, post top luminaires are as garage roof tops, emergency
Safety Code specifies that "the extent to which emergency lighting needs to be bollard. This diminutive product traditionally an excellent method illumination may also be required.
provided outside of the building should be to either a public way or a distance provides appropriate pathway for pathway lighting. Gardco is Gardco's extraordinary architectural
from the building that is considered safe" (Section A.7.9.1.1). Depending on the illuminance with no light trespass renowned for their offering of clean site luminaires, such as the Gullwing
behind the luminaire. Using the same contemporary post top products with shown above, are all offered with
provisions of the local ordinances, failure to comply with this code may result in battery backup system as the exceptional lighting performance. emergency quartz lampholders as a
fines or criminal prosecution. These codes are now more strictly enforced than complimentary recessed steplight, These products are offered with an standard option.
ever before. the emergency lighting system may emergency quartz lampholder option.
now be extended away from the
building to the street or parking area.

two three
FLUORESCENT BACK-UP SYSTEM QUARTZ LAMP SYSTEMS
Most Gardco outdoor wall sconces are available with the EMR option that allows for path of egress emergency
The emergency quartz options are offered with most Gardco HID
lighting. The luminaire is supplied with an integral LED charge indicator and test switch. A 7.5' whip is provided for
luminaires and are designed to address the problems of providing
wiring to a Bodine B84C* fluorescent emergency ballast – supplied by the contractor or the factory. The emergency
ballast is remotely installed in the plenum safely away from outside temperature extremes. The diagram below emergency lighting during power outages (Q924) and the extended
illustrates how this luminaire can be used for emergency applications. darkness due to the time required for the restriking of HID lamps (QS
and QST). These options are fully described below.
*B94C-CAN in Canada

When the Q924 option is specified in conjunction with a back up


7.5' long, 11 conductor
interconnect cable with inverter system, the emergency lighting system becomes
connector in minimum incorporated into the standard lighting system. In this scenario, both
1/2" conduit.
the standard and the emergency lighting systems are less
4-11/16" susceptible to vandalism and are UL listed for Wet Locations.
Wall switch Junction Box
(by others) (by others)
4-11/16"
Outlet Box
(by others)
Standby Line 277V Lamp Black
Bodine B84C Emergency 7.5' long, 11 conductor This option is also known as "quartz restrike". 120 HID Ballast
Input HID Lamp
Fluorescent Ballasts (by interconnect cable with When power is restored after an outage or Leads Common Common White
others) w/Flexible whips connector in minimum
when the generator or inverter comes on line, Ground Yellow
1/2" conduit.
4" Octagonal the quartz lamp will be energized until the HID Quartz
Black Standby Red
by 2-1/8" deep source strikes an arc and will then immediately Relay
Bodine B84C Emergency
J-box (by others) extinguish. The QS option is covered under UL White Quartz Halogen Lamp
Fluorescent Ballast (by 120V
others) w/ flexible whips 1598 for HID products and is designed for use
Electrical Feed
with only one power circuit (branch circuit).
Sconce Emergency
Plan View (typical) Ready Luminaire
with test switch
and LED indicator

7.5' long,
4" Octagonal
by 2-1/8" deep
Standby Time Delay Line 277V Lamp Black
11 conductor J-box (by others) Like the QS option, the QST relay also Input 120 HID Ballast
interconnect Common Common
HID Lamp
cable with
energizes the quartz lampholder after power is Leads White
Ground
connector restored. However recognizing that HID lamps Yellow
in minimum often take a few minutes to come up to full light Quartz
Black Standby Time Red
1/2" conduit. output, with the QST the quartz lamp will remain Delay Relay

on until the HID lamp reaches approximately White Quartz Halogen Lamp
120V
80% of full light output. This option is also
Sconce 4" Octagonal
by 2-1/8" deep covered under UL 1598.
Wall Switch
J-box (by others) (by others)

Wall switch (by others)

Lampholder Line 277V Lamp


The Q924 option (formally offered as the QEM Normal HID Ballast
Input HID Lamp
option) consists of a quartz lampholder and Leads
Common Common
Section (typical) leads designed for a dedicated power source Ground
separate from the primary HID source. The
Q924 is designed for use with an emergency
Emergency
power supply source (generator or inverter). Input 120V
Leads
Luminaires with this option are listed under Neutral
Quartz Halogen
UL924. Emergency Lamp

four five
EMERGENCY OUTDOOR LIGHTING– 94EM LINE – EMERGENCY AISLE LIGHT AND BOLLARD
A P P L I C AT I O N S The horizontal 942EM and the vertical 943EM recessed steplights are the most inconspicuous wall mounted emergency luminaires
available. Because they meet ADA requirements for maximum projection from the wall, they can be mounted low to the ground and
provide the emergency illumination precisely where it's needed.
The most common applications for outdoor emergency lighting are building perimeters, pathways, commercial
parking garages, and garage rooftops. Because of their clean, architectural styling and low mounting height capability, the 94EM luminaires are also an excellent product
for indoor emergency applications. With the potential for a smoke filled environment, low level emergency lighting systems are often
preferable to ceiling mounted emergency lighting products. However, indoors or outdoors, these elegant, recessed emergency
Building Perimeters Pathways luminaires are a superior aesthetic alternative to the traditional industrial "frog eye" type emergency wall packs.

Emergency Aisle Light Emergency Bollard


The 94EM series of The 943BEM bollard is an
emergency steplights elegant solution for
utilize an integral emergency pathway
emergency pack lighting. This unidirec-
consisting of a high- tional bollard provides
temperature nickel- appropriate illuminance on
cadmium battery with the pathway with no light
charger and electronic trespass behind the
circuitry. When AC power fails, the luminaire immediately switches luminaire. Using the same
to the emergency mode, keeping one lamp illuminated at a battery backup system
reduced lumen output for a minimum of 90 minutes. When AC as the complimentary
power is restored, the emergency battery system automatically recessed steplights, the
returns to the charging mode. The indicator light is mounted 943BEM extends the emergency lighting system away
Stepping outside of building during a power outage should A safe parking area or public street may be located a behind the prismatic glass and the test switch is discreetly placed from the building to the street or parking area.
provide a sense of relief. If however all street lighting is also considerable distance from the building. In addition, public within the horizontal tiers of the die cast faceplate.
out, the building exterior may seem equally unsafe. If the parks, campuses, or deserted office complexes may be
cause of the power interruption is weather related, this will especially unsafe environments during a power outage. By 8.5"
5.5"
increase the likelihood of heavy cloud cover eliminating helpful simply providing a few emergency bollards or post top 13" 8.5"
5.5"

moonlight or starlight. Building mounted emergency luminaires along the primary pathways, pedestrian traffic can 5.5"
luminaires may provide sufficient illumination to enable be safely directed as required. 13"
15.8"
pedestrians to proceed to a safer location.
5.5" 5"
943EMB25 = 25"
943EMB40 = 40"

Commercial Parking Garages Garage Rooftops 8"


(RF) Stacked
Specular Louvers
Behind Tempered
Glass

5.5" (RFPLY) Stacked


Specular Louvers
Behind Clear
943EMB25 Polycarbonate

8.5" 943EMB40

Ordering
Prefix
942EM – Emergency Horizontal Steplight
PREFIX WALL TYPE WATTAGE FACEPLATE VOLTAGE FINISH 943EM – Emergency Vertical Steplight
943B25EM – Emergency 25" Bollard
942EM D/C 213TFE PG* 120 BGP 943B40EM – Emergency 40" Bollard

943EM RF 277 BLP Wall Type


D/C – Suitable for drywall or concrete pour applications.
Insulating material if present, must be kept at least 3 inches
943B25EM BOLLARD RFPLY BRP away from the luminaire. Units are thermally protected.

Commercial parking garages can be one of the most On a clear moonlit evening, it may not be too difficult for 943B40EM NP Faceplate
PG – Prismatic Glass
foreboding environments in a power outage. In addition to pedestrians to locate their vehicles in parking lots or on
WP RF – Stacked specular louvers behind tempered glass
normal anxiety about crime, there is a high probability for garage rooftops. However during a storm or blizzard when RFPLY – Stacked specular louvers behind clear
polycarbonate
tripping over curbs and obstructions. In addition, the simple power outages are more likely to occur, this can be an OC
act of locating a vehicle in a brightly lit parking structure may extremely frustrating and unsafe exercise. Utilizing quartz Finish
become an impossibility in a fully darkened garage. emergency lampholders in the site luminaires can be a simple SC BGP – Beige Paint OC – Optional Color Paint
way to provide adequate lighting for pedestrians in this BLP – Black Paint Specify RAL designation as
BRP – Bronze Paint shown in Color Selection Guide.
environment. Example: 942EM-D/C-213TFE-PG-277-BLP *942EM Only
NP – Natural Paint Ex: OC-RAL7024
WP – White Paint SC – Special Color Paint
Specify. Must supply color ship

six seven
100EM LINE – EMERGENCY SCONCES 100EM LINE – EMERGENCY SCONCES
The 100EM LINE is a series of luminaires that is perfectly suited for 101 103 / 104 107 111
exterior emergency applications. In addition, their elegant forms
make them equally appropriate for providing emergency 7" 7" 7.5" 5.34"

illumination to commercial interior spaces. These sconces are


available with battery/emergency ballasted compact fluorescent 16.25" 9" 18" 9"
21.25" 11.5" 12.13" 7"

lamps. The indicator and test switch are clearly visible through the
lens. The door frame hinges for quick access to the test switch. The 102 106 108
sconces may be configured for switched or unswitched operation.
25 7/16"

The 100EM series luminaires utilize an integral emergency pack 8.25" 9.13"
7 1/8"
consisting of a high-temperature nickel-cadmium battery with
22 1/8"
charger and electronic circuitry on an open circuit board. The 16.5" 9" 18" 9"

100EMR luminaires utilize remote emergency battery packs and


electronic circuitry (which must be ordered separately with the
luminaire or provided by others). The 100EMR series should be
utilized in applications with extreme ambient temperature conditions. When AC power fails, the 100EM/EMR luminaire
immediately switches to the emergency mode, keeping one or two lamps illuminated at a reduced lumen output for
Ordering
a minimum of 90 minutes. When AC power is restored, the emergency battery system automatically returns to the Distribution
PREFIX DISTRIBUTION WATTAGE VOLTAGE RING 2 FINISH OPTIONS MT – Medium Throw
charging mode.
101EM MT 42TRF 120 AR BGP B84C 3
Ring (108 series only)
101EMR 226QF 1 277 LR BLP PCB AR – Aluminum ring painted to match housing, unless
102EM OR BRP SL specified differently
LR – Luminaire supplied without ring
Choice of Exquisite Daytime Forms 102EMR SR NP WG OR – Optional color ring. Specify color,
103EM WP WS Choice of Blue, Green, Red, Amber, White (clear)
SR – Brushed stainless steel ring
103EMR OC
104 EM SC
Finish
104EMR
BGP – Beige Paint OC – Optional Color Paint
106EM BLP – Black Paint Specify RAL designation as
106EMR BRP – Bronze Paint shown in Color Selection Guide.
NP – Natural Paint Ex: OC-RAL7024
107EM WP – White Paint SC – Special Color Paint
107EMR Specify. Must supply color ship
111EMR Mini Wedge 101EM/101EMR Square Wedge 102EM/102EMR Round Wedge 103EM/103EMR Up/Downlight 108EM Options
108EMR B84C – (EMR series only) Bodine Emergency Pack.
111EMR Must be ordered here or supplied by others.
PCB – Button type photocontrol
SL - Solite® diffusing lens
Example: 101EM-MT-42TRF-277-BRP-WS WG – Wire guard
1 = Not available on EMR series 2 = 108 series only 3 = EMR series only. Not included standard WS – Wall mounted box for surface or through wall conduit feed

HID Sconces with Emergency Quartz Options

104EM/104EMR Half Cylinder 106EM/106EMR Quarter Sphere 107EM/107EMR Gullwing 108EM/108EMR Circa
Where higher light levels are required in the non-
emergency mode, the HID sconces are a perfect choice.
The standard HID sconces are available in ten shapes,
Complimentary Non-Emergency Sconces three sizes, and with lamp offerings up to 400 watts in
either metal halide or high pressure sodium. Most of these
The graceful styling, exceptional performance, "full cutoff" illumination, remarkable versatility, and rugged construction products are offered with quartz standby (restrike),
have made the standard Gardco 100 Line the industry leader in commercial outdoor sconces. By applying the 100EM standby time delay, or quartz emergency lampholder
series on the same site as the standard 100 Line, you can achieve low brightness illumination, an elegant daytime options. These options are fully described on page five.
form, and a concealed exterior emergency lighting system.

eight nine
EMERGENCY QUARTZ OPTIONS EMERGENCY QUARTZ OPTIONS
Quadra
P o s t To p L u m i n a i r e s F o r P a t h w a y I l l u m i n a t i o n
The Gardco Quadra garage luminaire offers a unique Type 1R rectangular lighting
distribution which was designed for the specific geometric characteristics of Cutoff post top luminaires provide excellent pathway The Gardco
commercial parking structures. This extraordinary optical system directs peak lighting by producing low glare illumination and a Round Form 10
confined distribution from a pedestrian scale source. post top series
candlepower in the corners resulting in higher minimum light levels, fewer dark
features a pure
zones, minimum wasteful pattern overlap, and more uniform illumination. In addition, Specifying a quartz lampholder in the luminaire head and semi-spherical
the cutoff design significantly reduces discomforting glare in drivers' eyes. Also, the a backup emergency system will extend these benefits to or cylindrical
uplight window fills in dark ceiling coffers creating a less foreboding environment. periods of power outages. Furthermore, the units are form with a
distinctive
thoroughly sealed against the elements and the backup
architectural
power source (by others) is unaffected by outdoor reveal.
temperature extremes.
Ordering Dimensions

PREFIX WATTAGE VOLTAGE OPTIONS


GP1 70HPS 120 QS – Quartz Standby, DC Bayonet Lampholder
100HPS 277 QST – Quartz Standby, Timed Bayonet Lampholder
150HPS Q924 – Quartz Emergency Lampholder Only
16.25"
Site Luminaires
70MH POLY – Polycarbonate downlight lens
TP – Spanner Head Tamper Resistant Screws An emergency quartz lampholder option is offered on many Gardco site luminaires. Consequently, no sacrifice in the
100MH
F – Fusing quality of area lighting is required when specifying an emergency outdoor lighting system for confined sites such as
150MH
DR – Supplementary Downlight Reflector parking structure rooftops. All feature the unique Form10X optical system which provides high light levels, uniform
175MH (Provides additional area illumination and masks uplight)
illumination, wide pole spacings, sharp cutoff of glare, and excellent energy efficiency.
175PSMH BX – Bird Excluding Shroud
200MH JB – Balanced J-Box with offset knockout
(For non-rigid sway pendant mount)
LFI – Lamp factory installed
11.5" The Gardco Square
IRS – Instant Restrike (HPS only. Consult factory) Overall to These Round Form10
TM – Trunnion Mount
Top of
Mounting Plate
Form 10 series is the arm mounted units
KWR – Kilowatt Reduction Option (Consult factory) classic rectilinear cutoff feature pure forms
11"
Luminaire luminaire which has set which subtly
the standard for high compliment
performance site lighting architectural details
Example: GP1-150HPS-277-Q925-LFI products for over a such as domes,
quarter of a century. arches and columns.

Designer Canopy Luminaire


The Gardco Designer Canopy Luminaire is semi-recessed, but fully
elegant. The optical systems offered in this ceiling mounted unit feature
deeply recessed lamp positioning to provide sharp visual cutoff to the
lamp and lamp images at normal viewing angles. Luminaires are A form inspired by Circa is the newest
available with either downlight or wall wash distributions. birds soaring in flight, Gardco site luminaire
The Designer Canopy Luminaire features a silicone gasket which the Gardco Gullwing and is characterized
excludes moisture, dust, insects and pollutants. By simply specifying is a luminaire without by a remarkably low
quartz emergency lampholders with the Designer Canopy Luminaire in compromise. The profile and a distinctive
conjunction with a back up inverter system, the emergency lighting elimination of the architectural ring.
mounting arm Although designed for
system can be artfully incorporated into this extraordinary lighting conventional arm
system without detracting from the architectural design. In addition, provides the striking
mounting, it presents
both the quartz standby and the quartz standby time delay options are effect that pole and
an especially seamless
luminaire become a transition when mast
available with the Designer Canopy Luminaire. These are all fully
single natural entity. arm mounted.
described on page five.

ten eleven
For complimentary, non-emergency product lines, these brochures may be obtained from your
local Gardco representative or by visiting www.sitelighting.com.

100 Line Sconces Step and Aisle Lights Garage Luminaires Canopy Luminaires

DESIGNER CANOPY LUMINAIRE


B U I L D I N G M O U N T E D

GARDCO
GARDCO
LIGHTING
LIGHTING

2661 Alvarado Street


San Leandro, CA 94577
800/227-0758
510/357-6900 in California
Fax: 510/357-3088
sitelighting.com
© Gardco Copyright 2002
Genlyte Thomas Group LLC
All Rights Reserved.
International Copyright Secured.
79103-28/902

Das könnte Ihnen auch gefallen