Sie sind auf Seite 1von 10

Disclaimer

Our policy is one of continuous development. Accordingly the design of our products may change at any time.
Whilst every effort is made to produce up to date literature, this document should only be regarded as a guide and is intended
for information purposes only.
Its contents do not constitute an offer for sale or advice on the application of any product referred to in it. We cannot be held
responsible for any reliance on any decisions taken on its contents without specific advice.

Page 1 of 10 489554507.xls 09/04/2020


Order form MiCOM P220
Ready-to-use configuration

P220 Numerical Motor Protection P220 C 0

Earth current input


0.002-1 Ion C
Voltage input
None 0
Mounting Option
None (default) 0
Pre-fixed HMI (no withdrawability) 1
Sealed cover 2
Pre-fixed HMI + Sealed cover 3
Auxiliary voltage Digital input voltage
48 - 250 Vdc / 48 - 240 Vac 105 - 145 Vdc H
48 - 250 Vdc / 48 - 240 Vac 110 Vdc -30%/ +20% V
48 - 250 Vdc / 48 - 240 Vac 220 Vdc -30%/ +20% W
24 - 250 Vdc / 48 - 240 Vac 24 - 250 Vdc / 24 - 240 Vac Z
Communication protocol
Modbus / Modbus (if 2nd RS485 available) 1
K-Bus / Courier / Modbus (if 2nd RS485 available) 2
IEC60870-5-103 / Modbus (if 2nd RS485 available) 3
IEC60870-5-103 / IEC60870-5-103 (if 2nd RS485 available) 5
Language Platform
French 0
English / American 1
Spanish 2
German 3
Italian 1) 4
Russian 5
Polish 6
Portuguese 7
Dutch 1) 8
American 1) 9
Czech A
Hungarian 1) B
Greek 1) C
Chinese 3 only D
Turkish 1) E
Platform
SE look&feel Phase 2 2
SE look&feel Phase 2 with larger LCD 3
Option: Temperature / IRIG-B + Sec.comm.Port
+ 5 DI
No 0
IRIG-B / Sec.comm.Port / 5 DI 1
2 thermistors monitoring 3
6 RTDs monitoring A
Optional analogue Output/Outputs
No 0
2 analog outputs 2
Software
version **
NOTES :
1)
Not yet available

09/04/2020
Order form configurator MiCOM P220
Ready-to-use configuration

1-4 5 6 7 8 9 10 11 12 13 14 15

Motor Protection P220 C 0 0 H 1 0 2 0 0 C B


SAP PART NUMBER E220C00H10200CB
Earth Current Input
0.002 - 1 x Nominal Earth Current C
Voltage Input
None 0
Mounting option :
None (default)
Pre-fixed HMI (no withdrawability) 0
Sealed cover
Pre-fixed HMI + Sealed cover
Auxiliary Voltage / Digital input voltage
48 - 250 Vdc / 48 - 240 Vac 105 - 145 Vdc
24 - 250 Vdc / 48 - 240 Vac 110 Vdc - 30% / +20%
H
220 Vdc - 30% / +20%
Communication protocol
Modbus / Modbus (if 2nd RS485 available)
K-Bus / Courier / Modbus (if 2nd RS485 available) 1
IEC60870-5-103 / Modbus (if 2nd RS485 available)
IEC60870-5-103 / IEC60870-5-103 (if 2nd RS485 available)
Default HMI (Human / Machine Interface) Language
French
English / American
Spanish
German
Italian : not available
Russian
Polish 0
Portuguese
Dutch : not available
American : not available
Czech
Hungarian : not available
Greek : not available
Chinese
Hardware Version
Turkish : not available
Phase 2 with standard display 2
Option: Temperature / IRIG-B + Sec.comm.Port + 5 DI
No
IRIG-B / Sec.comm.Port / 5 DI 0
2 thermistors monitoring
6 RTDs monitoring
Optional Analogue Outputs
No 0
Yes
Software Version
Software Version V12.B
Software Version V12.A CB
Software Version V11.C
Software Version V11.A

09/04/2020
Master Text

P220C00H10200CB

Motor Protection

Earth Current Input :


0.002 - 1 x Nominal Earth Current

Page 4 of 10 489554507.xls 09/04/2020


Issue : 015 - RKLI-A7UABP ... S/W version V12.B release - 04/04/16
Issue : 014 - RKLI-9TC5Y2 ... S/W version V10.C withdrawn from offer - 11/2/15
Issue : 013 - As per RKLI-9R9922 - V12.A software version released - 15/12/14
Issue : 012 - As per RKLI-9MSDLV - Dutch language option removed from offer - 22/08/14
Issue : 011 - As per RKLI-9K97DE - V11.C software version released - 28/05/14
Issue : 010 - As per SBIA-94GB5G - ABB Entrelec connector replaced by new interface board and back plate - 19/0
Issue : 009 - As per SBIA-8SCJCR - Equipped boards introduced - 23/05/13
Issue : 008 - As per SBIA-8ZYH6M - SW version V11.C invalidated for Chinese language option - 17/12/12
Issue : 007 - SW Release V11.A per RSCH-8VPCZU - 11/07/12
Issue : 006 - Tendering sheet added - 22/02/12
Issue : 005 - SW Release V10.C per SBIA-8BNGW2. Phase 1 removed from configurator, SW availability updated
Issue : 004 - Cortec code 3 and A for optional temperature monitoring added as per SBIA-8ECC8B
Issue : 003 - Auxiliary Voltage rating for Universal Power Supply option, 'Z', amended to 24-250Vdc/48-240Vac as
Issue : 002 - As per SBIA-89D9PB, phase 2 release - 28/07/10
Issue : 001 - Derived from existing Cortec/Configurator, reformated as other Px2x - 07/04/10
NUMBER DESCRIPTION

P220C00H10200CB
E207030601 Blanking Plate 30TE
E2072078A1 Extension Board
E20720819Z Power Board
E517060101 Operator Label
E517719101 Screws kit
E517725101 Product Label
E517837101 Extractor
E517998101 2 way connector assy
E518326104 Connection Diagram
E518327102 Packing 30TE
E518414110 Assy front interface 30TE
E843992001 Cable tie
EGN0383005 Case and Chassis Assembly
EZB4018118 Self Tapping Screw Flange Head size 4x /4
1 "

EZB4018118 Self Tapping Screw Flange Head size 4x /4


1 "

EZB5017036 Washer Spring Single Coil M3 Steel


EA00026928 VCI Bag
EZB5321126 Screw M3 x 16 Recessed Pan Head Steel
Qty.
Ref
Required

4 1

4
1
4
6 2
PL3/PL5 1
1
1
3, 4, 5, 7, 8 1
6
1
12 12
12 5
10 6
1
9 6
1
1 2 3 4 5 6 7 8 9 10 11 12 13 14

Cortec Landing cell : P220C01W56210BA P 2 2 0 C 0 1 W 5 6 2 1 0 B


Configurator feedback : P220C00H10200CB P 2 2 0 C 0 0 H 1 0 2 0 0 C

Cortec digit control 1 P


Cortec digit control 2 2
Cortec digit control 3 2
Cortec digit control 4 0 C 0
$B$11 1 0
$B$17 1 H
$B$22 1
$B$27 1 1
$B$33 1 0 2
$B$51 1 C
$B$64 1 0
$B$70 1 0
15

A
B double digit in same row

5
6
7
8
9
10
11
12
13
B 14
15
16
0
0
0
0
0
0
0
0
0
0
0
0
0
0