Features Description
• Superior versatility The Parker Series MV3 Midget Directional Control Valves
provide multiple-function directional control in series, parallel
• Both open and closed center configurations
and series-parallel circuits. Proven for more than 30 years in
• Excellent metering characteristics
thousands of mobile and industrial hydraulic systems, these
• Inlet load drop checks Parker Midget Valves are modular in design and can be
Optional high flow inlets (low ∆P) assembled in a wide variety of circuit configurations.

• Fourth position float

• Combinable with Parker Mini-Pak solenoid operated


directional control valves

• Power beyond feature

Specifications

Operating Pressure: 3000 PSI (207 Bar) maximum.

Power Beyond Pressure Capability: 3000 PSI (207 Bar).


Operating Fluid: Standard petroleum-based.
Leakage C-T at 3000 PSI (207 Bar): 5.4 in3/min. (88.5 cc/min.) at 100°F (38°C), 150 SSU (32 cSt).

Handle Pull Force at 3000 PSI (207 Bar): 15 lbs. (66.6 N) maximum, spring centered or detent.
Filtration Requirement: Recommend 25 micron (nominal). Class 18/15 according to ISO 4406, or cleaner.

1 Parker Hannifin Corporation


Hydraulic Valve Division
Elyria, Ohio, USA
Bulletin HY14-2000-B10/US
Supersedes: VPB-19 dated 1999

Model VA35 Automatic Kick-Out


Available in Tandem and Parallel

Model VA35 automatic kick-out valve sections are used to operate


multiple functions that have a definite sequence of operation with
very little input or effort from the machine operator. Simply move all
the auto kick-out section handles to a detented work position and the
valve does the rest. If tandem sections are used, the section will
activate in upstream to downstream order one after the other.

All pump flow is delivered to the first section function until the pressure of that function rises to the
pressure setting of the back cap. At this point, a small relief valve in the back cap activates and releases
the detent, sending the section's spool back to neutral. The next section in the bank now receives the full
pump flow and the process repeats until all the auto kick-out spools are back in neutral.

If parallel sections are used, the sequence of operation is determined by the pressure needs of each
function. The section with the lowest pressure requirement will move first, the section with the next lowest
pressure requirement would activate next and so forth.

There are also sections available that are controlled by an external pressure signal.