Sie sind auf Seite 1von 2

FLEXIM

More than 25 years of experience in


clamp-on ultrasonic flow measurement technology
Permanent ultrasonic flow meter for Oil reservoir management

FLUXUS® F502FM
FLEXIM AMERICAS
Corporation Ultrasonic Flow Meter for
Headquarters
250-V Executive Drive Upstream Water Flow measurements
Edgewood, NY 11717
Phone: (631) 492-2300
Accurate – Reliable – Durable
FLEXIM has offices located
throughout North America.

Please have a look for your


Technical Data FLUXUS® F502FM local representative at:

Measuring system: Permanent non-invasive ultrasonic flow meter for volume Accurate and cost-efficient
flow and flow velocity measurement of water and glycol www.flexim.com
_______
or call us at:
For pipe size (ID): 1” - 12”
(independent of pipe material and wall thickness) 1-888-852-PIPE Completely maintenance-free
Flow velocity: 0.03 ... 82 ft/s _______
Accuracy: ±1,5% of reading ±0.03 ft/s
Absolutely reliable
Repeatability: 0.25% of reading ±0.03 ft/s
_______
Protection class acc. Transmitter: NEMA 4X (IP66) – FM Class1 Div2
to IEC/EN 60529: Transducers: NEMA 6 (IP67) – FM Class1 Div2
Robust design
Outputs: 2x Current output, 1(2)x Binary

Communication RS485 (sender), Modbus RTU


(optional):

Data logger: >100,000 measured values

BUF502FMV1-1US 12/2018 Subject to change without notification!


Please contact your local FLEXIM support office for more details.
Visit: www.flexim.com/contact
Getting more measurement data with FLUXUS® –
Ideal for optimizing of the oil reservoir management without additional

drilling activities

Water Management Advantages Completely maintenance-free and reliable


______ ______ ______

Water is vital for the development and stimulation of new wells. From the well head to processing and disposal it is pp Water flow measurement FLEXIM was the first clamp-on ultrasonic flow meter manufacturer
necessary to track water for production, environmental and regulatory reasons. Many different types of applications without media contact - to overcome the need of gel as a coupling material between the ultra-
require water flow measurement from fracking, to produced water, to water disposal. Different types of insertion meters no wear and highly reliable sonic transducer and the pipe. Coupling gel can dry out or be washed
are utilized but maintaining these meters can be very time consuming and expensive. The FLUXUS® 502FM is never in pp Installation and set-up away with time when being flooded - operators thus have to regularly
contact with the liquid, or sometimes very high pressures associated with these applications. With the use of permanent without pipe modification check and if necessary replenish the coupling gel. To do so, the trans-
coupling pads and robust mounting tracks the FLUXUS® F502FM is a maintenance free meter. and line shut-down ducers have to be taken from the pipe, covered with new gel, and then
reinstalled. Even experienced staff can make mistakes during this
pp Permanent pipe wall
Effortless and cost-efficient installation coupling - no need for
regular maintenance task.
______ maintenance
pp Robust design - highest Due to its long-term stable permanent coupling pads the FLUXUS®
The FLUXUS® F502FM is installed with no need for pipe modifications and without any process interruption. Moun-
protection against any F502FM overcomes such cost intensive maintenance tasks and en-
ting and device set-up can be completed by just one person in a short time. Thereafter, the FLUXUS® F502FM delivers
mechanical stress sures absolute measurement reliability.
accurate, highly repeatable and long term stable measurements.
pp Superior low flow capabilities
pp Advanced noise suppresion
Unrivalled measurement sensitivity and stability and strong signals for stable
Furthermore, as of its contact-free measurement principle, the
FLUXUS® F502FM shows no signs of wear, something which can
______
measurements even on happen to conventional wetted flow meters, such as electromagnetic
The FLUXUS® F502FM not only accurately and reliably measures over a wide flow velocity ranges, it also features excellent challenging pipes meters, where electrodes and inner liners corrode or deposit is building
low flow capabilities (down to 0.03 ft/s) and is independent from pressure rating. FLUXUS® F502FM an ideal flow meter, pp Independent from pressure up, leading to measurement drift and increased maintenance efforts.
even on high pressure water injection applications and fracking. rating

Applications Designed for challenging applications


______ ______

pp Measurements of water The FLUXUS® F502FM is offered with high-quality built-to-last


injection wells transducers and the most robust mounting system on the market. All
pp Measurement of produced FLEXIM transducers are built without connection on the transducer
water after separator head to protect them against water and dust ingress. The VARIOFIX
mounting system is made of stainless steel and completely covers the
pp Measurements on any other
sensors ensuring long-term excellent installation protection.
water filled pipes
pp All wastewater applications;
influent, effluent, RAS, WAS,
chemical injection
pp Water management of
fracking operations

2 3