Sie sind auf Seite 1von 2

860 10006

860 10026
Central Control Unit
The Central Control Unit provides the site interface between
the several RCU’s and the control system, whether it be a
local laptop, remote laptop, or via Ethernet to the system
switch. AC or DC-powered, the Central Control Unit also
provides all logical controls and DC power to the RCU’s. For
indoor use only.
Specifications: ##5)NTERFACES
Connectors 3 x 8 pin connector
according to IEC 60130-9, female, X23
conforms to AISG X6X6
tightening torque for 0.4–0.7 ft-lbf
attaching connectors hand tighten only ##5
Power supply from BTS #ENTRAL#ONTROL5NIT
860 10006 DC: -48 V /max. 1.7 A
AC: 100 V–240 V / 50–60 Hz
max. 1.6 A

X/PEN
#OLLECTOR
%THERNET
23
860 10026 DC: -48 V /max. 1.7 A
Power supply to RCU 3 x +29 V / max. 1.7 A (in total)
3 x +13 V / max. 3.8 A (in total)
Total output power 50 W max.
.ETWORK !LARM

!#n6
MAX!
ONLY
$#n6
MAX!

'.$
Interface to RCU and TMA RS 485 / power supply
)NTERFACES )NTERFACE
Protocol to RCU and TMA HDLC hex-coded command set
conforms to AISG
Interface to BTS Ethernet (10 base T) and RS 232
Protocols to BTS TCP/IP, PPP, HTTP/HTML, UDP,
DHCP, FTP, SNMP, ICMP/PING
Alarm interface to BTS 8 x open collector output
user programmable %XAMPLESOF##5n2#5CONNECTIONS
Max number of RCU's 27 (depending on cable configuration*)
see charts on reverse for details
Max number of DTMA's 6 (depending on cable configuration*)
Temperature range -25°C – +55°C
Dimensions 19 inches x 1 HU (height unit)
19 x 9.8 x 1.7 inches
(483 x 250 x 43.6 mm)
Shipping dimensions 23.5 x 14.4 x 5.8 inches
(597 x 367 x 148 mm)
Standards EN 60950-1 (Safety)
EN 55022 (Emission)
EN 55024 (Immunity)
UL 60950-1, 1st edition
Certifications CE
FCC 15.107 Class B
UL
* For specific configuration requirements call Kathrein Scala Division
Communication Sales Engineering.

Order Information: TO##5


Model Description
860 10006 Central control unit, AC/DC power supply
860 10026 Central control unit, DC power supply
Both units include the Central Control Unit, Manual, DC Cable,
ethernet crossover cable. The 860-10006 also includes U.S. and
European syle AC Power Cords.

Optional Accessories:
Description
Null modem RS-232 cable for connection t o a local laptop computer KATHREIN 860 10006, 860 10026

Tested To Comply
With FCC Standards
This device complies with part 15 of the FCC Rules.
Operation is subject to the following two conditions:
(1) This device may not cause harmful interference,
and (2) this device must accept any interference
received, including interference that may cause
10729-K undesired operation.
936.2310/f
Kathrein Inc., Scala Division Post Office Box 4580 Medford, OR 97501 (USA) Phone: (541) 779-6500 Fax: (541) 779-3991
Email: communications@kathrein.com Internet: www.kathrein-scala.com
860 10006
860 10026
Central Control Unit
19 inches The maximum control cable length (Lmax)
(483 mm) depends on the type of RET configuration.
In star configuration with one control cable
1.7 inches for each sector, the max. length of the con-
(43.6 mm) trol cable depends on the number of RCUs
17 inches per sector (N_RCU/sector). In daisy-chain
(432.4 mm) configuration, the max. length depends on
the total number of RCUs (n_RCU).
The length values are listed in the tables
below.
9.8 inches
(250 mm)
Star Configuration
9 inches N_RCU/sector L1max in m
(228.8 mm) 1 220
2 190
3 170
4 150
5 130
6 110
7 100
8 90
Star Configuration Daisy-chain Configuration 9 90

Daisy-chain Configuration
N_RCU Lmax in m
1 280
2 270
3 260
4 250
5 240
6 230
7 220
8 210
9 200
10 190
11 180
12 170
13 170
14 160
15 150
16 140
17 140
18 130
19 130
20 120
21 120
22 110
23 110
24 110
25 100
26 100
27 100

All specifications are subject to change without notice. The latest specifications are available at www.kathrein-scala.com.