BS EN 12681-1:2017

EN 12681-1:2017 (E)

Table A.2 — Image quality requirements for testing class B

Minimum wire Maximum step Minimum Maximum step


Penetrated thickness
IQI value hole IQI value wire IQI value hole IQI value
Lower Upper
thickness limit thickness limit IQI at source side IQI at film sidea
mm mm
2 W 18 H2 W 18 H2
>2 3,5 W 17 H3 W 17 H3
> 3,5 5 W 16 H4 W 16 H4
>5 7 W 15 H5 W 15 H5
>7 10 W 14 H6 W 14 H6
> 10 15 W 13 H7 W 13 H7
> 15 25 W 12 H8 W 12 H8
> 25 32 W 11 H9 W 11 H9
> 32 40 W 10 H 10 W 11 H9
> 40 55 W9 H 11 W 10 H 10
> 55 85 W8 H 12 W9 H 11
> 85 150 W7 H 13 W8 H 12
> 150 200 W6 H 14 W7 H 13
> 200 250 W5 H 15 W7 H 13
> 250 380 W4 H 15 W7 H 13
> 380 W3 H 16 W7 H 13
a IQI may be located on film side only, if positioning on source side is not possible

Tables A.1 and A.2 show the minimum image quality values for metallic materials. If the image quality is
disturbed by mottling effects the image quality values may be determined in accordance with
EN ISO 19232-4 by agreement between the contracting parties.
In the case where Ir 192 or Se 75 sources are used, IQI values worse than the ones listed in Tables A.1 to
A.2 may be accepted as shown in Table A.3.