4 core 25 sq mm copper 1 - 0 - - -
4 core 4 sq mm copper 1 - 0 - - -
4 core 16 sq mm copper 1 - 0 - - -
4 core 50 sq mm copper 1 - 0 - - -
2 core 4 sq mm copper 1 - 0 - - -
1 - 0 - - -
13 Approximate cost of cables 11.1 to 11.7
105 681 71,500 40 - 681 27,240
14 1) Supply of 1.5mLx1m B Cast Iron cheque 133 3960 5,26,680 13 - 3,960 51,480
2) Fitting charges of 6mm thick chequer in 133 800 1,06,400 23 - 800 18,400
15 END & CORE TERMINATION-HT CABLE . 0 - - -
185 sq mm 6 3850 23,100 0 - 3,850 -
16 STRAIGHT JOINT FOR LT CABLE 0 - - -
Supply and making straight through joint fo .
185 sq mm 2 7700 15,400 2 - 7,700 15,400
17 EARTHING . -
Arranged Materials and
Supply and providing plate earthing as per 6 16500 99,000 6 - 16,500 99,000 50% waiting for Machinery
Erection at site
Arranged Materials and
Supply and providing pipe earthling as per 3 11000 33,000 3 - 11,000 33,000 50% waiting for Machinery
Erection at site
18 Supply and providing the following sizes of . 0 - - -
450x450x10 mm cast iron gully trap with co 6 7700 46,200 6 - 7,700 46,200
300x300x10mm cast iron gully trap with co 5 5500 27,500 5 - 5,500 27,500
19 Supply and providing test joint for the earth . 0 - - -
Arranged Materials and
2x25x6mm tinned copper strip 6 3080 18,480 6 - 3,080 18,480 50% waiting for Machinery
Erection at site
Arranged Materials and
2x25x3mm tinned copper strip 4 1540 6,160 4 - 1,540 6,160 50% waiting for Machinery
Erection at site
20 Supply and providing earth lead from the te 4 1540 6,160 0 - 1,540 -
25x6mm copper strip tinned at the point of 50 1540 77,000 50 - 1,540 77,000
4.00 mm bare copper conductor (SWG) 50 253 12,650 50 - 253 12,650
21 Supply and laying strips of the following siz . 0 - - -
HEP/QSF/IECS/506 INSPECTION SITE REPORT ON PROJECTS
M/S QCSM, KARAMCODE, KOLLAM Time By Rajes Project QCSM, KARAMCODE
Date 15.08.2020 Chd CIBI Pr. Code
PROJECT PLANNING-BAR CHART Client QCSM Apd Saju REPORT SL.NO. 2
ORIGINAL TENDER -25536 spindles Existing Scope of Instalation - 7296 spindles
Tentaive date
% of stage Progress so far Steps to be taken to
Sl.No Commodity/Activity/ Description of 100%
completed achieved achieve the target
Qty Unit Rate Amount Qty Unit Rate Amount cmpletion
Arranged Materials and
25x3mm copper strip tinned at the point of 300 770 2,31,000 50 - 770 38,500 50% waiting for Machinery
Erection at site
Arranged Materials and
25x 6mm copper strip tinned at the point of 150 1650 2,47,500 150 - 1,650 2,47,500 50% waiting for Machinery
Erection at site
Arranged Materials and
3.15 mm copper conductor (10 SWG) 150 99 14,850 150 - 99 14,850 50% waiting for Machinery
Erection at site
Supply and laying the following sizes of str . 0 - - -
25x 6 mm copper strip tinned at the point o 350 1540 5,39,000 0 - 1,540 -
Arranged Materials and
4.00 mm copper conductor ( 8 SWG) 50 143 7,150 50 - 143 7,150 50% waiting for Machinery
Erection at site
22 MISCELLANEOUS . - - -
Supply and placing 2.5 mm thick and 1m w 20 1320 26,400 2 - 1,320 2,640
Supply and placing 2.5 mm thick and 1m w 100 1100 1,10,000 30 - 1,100 33,000
Supply and providing First Aid Chart duly f 15 1100 16,500 5 - 1,100 5,500
Supply route marker with 10 cm x 10 cm G 5 253 1,265 5 - 253 1,265
Supply and providing 5 Kg Dry chemical po 10 2750 27,500 4 - 2,750 11,000
Supply and providing 9 liter capacity GI fire 5 2530 12,650 3 - 2,530 7,590
23 LIGHTING .
Collected Materials and
1).Supply and wiring of three runs of 1.5 sq 88 1958 1,72,304 58 - 1,958 1,13,564 waiting for False Ceiling
Works at site
Collected Materials and
2). Supply and wiring of two runs of 2.5 squ 20 2970 59,400 10 - 2,970 29,700 waiting for False Ceiling
Works at site
24 Collected Materials and
Renovation of LT wiring in the Plant Area, 1 60000 60,000 1 - 60,000 60,000 waiting for False Ceiling
Works at site
25 PART - KSEB/KSEI CHARGES .
Proposal Waiting for Initial
Charges for preparing the electrical schem 1 60000 60,000 1 - 60,000 60,000 50%
Submitted KSEI Approval ffrom KSEI.
Total Value of the Electrical Workorder Awarded: 173,26,699 - 69,95,569
26 2500A Bus ducts of about 50m total length 2 6,50,000 13,00,000 -
HEP/QSF/IECS/506 INSPECTION SITE REPORT ON PROJECTS
M/S QCSM, KARAMCODE, KOLLAM Time By Rajes Project QCSM, KARAMCODE
Date 15.08.2020 Chd CIBI Pr. Code
PROJECT PLANNING-BAR CHART Client QCSM Apd Saju REPORT SL.NO. 2
ORIGINAL TENDER -25536 spindles Existing Scope of Instalation - 7296 spindles
Tentaive date
% of stage Progress so far Steps to be taken to
Sl.No Commodity/Activity/ Description of 100%
completed achieved achieve the target
Qty Unit Rate Amount Qty Unit Rate Amount cmpletion
Signature Signature
N Prepared
fM Approved N f Remarks
MD