Beruflich Dokumente
Kultur Dokumente
Carry out complete alignment survey work by total station along bridge
alignment, cross roads 100m. both sides, 200m. additional length from
both ends of bridge including marking of centre line of alignment, taking
ground level details of existing structures, details of all manholes,
catchpits, existing utility services, light poles, trees, over head electrical
lines, BSNL section pillar/ box, Torrent electrical boxes, PMT including
number marked on them, road dividers, foot paths, etc. within construction
2 area and additional areas/ lengths if required. Rate includes fixing MORT&H fifth revision Section – 1102, 2400
necessary reference pillars, establishing bench mark, establishing
foundation layout on ground, including submission longitudinal section,
cross section and drawing report of survey work in three hard colour copies
with soft copy in CD to Engineer-in-charge as directed for flyover and
approaches. Submission of drawing in hard copy and AutoCAD soft copy
as per specification.
Dismantling/ removing any type of service pipe lines of any dia upto
any depth including excavtion, removing of pipe, back filling, watering,
compaction, including tools, plants and scaffolding wherever necessary,
11 sorting the dismantled material, disposal of unserviceable material and MORT&H fifth revision Section – 202
stacking the serviceable material with all lifts and leads as directed by
engineer in charge.
Removal of existing any type of paving or paving stones of any type, any
size, any thickness in required depth including removing paver with spil
sub base and breaking sub base i.e concrete or metaling etc under the
supervision of concerned department, disposal unserviceable material with
14 all lifts and up to any lead at non objectional place and stacking the As Per Attached Specification Sheet
serviceable material (paver etc) upto near by store of client including
loading, unloading as directed by Engineer-in-charge.
Removal of existing kerb stones of any type, any size, any thickness in
required depth including removing kerb with base PCC including
excavation, disposal unserviceable material with all lifts and up to any lead
15 at non objectional place and stacking the serviceable material (kerb) upto As Per Attached Specification Sheet
near by store of client including loading, unloading as directed by Engineer-
in-charge.
Repairing damaged M.H./ I.C. and rasing M.H. up to road level incl.
removing damaged brick work and repairing by brick masonry in C.M. 1:6
16 and plaster in C.M. 1:4 and fixing C.I. steps and removing manhole cover As Per Attached Specification Sheet
and debris from MH and carting the same as directed.
Submit colour photographs (2592 x 1944 pixels, 5MP) of the work supply
at monthly intervals (set required as per R&B Authority of different stage of
work submitted along with each R.A.Bill), one set (Min. 30 Images) of hard
copy not less than 5" x 7" for the work scarried out during month. Photos
17 As Per Attached Specification Sheet
are also to be submitted in form of soft copy as per directed by engineer in
charge. Photos are also to be submitted in the form of soft copy (DVD/CD)
on monthly basis.
Providing and laying in situ M15 grade bedding concrete for construction
of cast in situ P.C.C block of standard size 900x300x150min or as directed
by Engineer in charge including groove in asphalt road pavment , white
As Per Attached Specification Sheet & CPWD Clause No - 5.4.1 to
22 washing ,shuttering, mixing in batch mix plant, compacting, curing etc.
5.4.10, .4.11.1, 5.4.11.4, 5.4.11.5, 5.4.12, 5.4.13.1, 5.4.13.2, 5.4.13.4
complete true to level and position as directed by Engineer and as per
specification.
Chipping and dressing of the RCC piles upto cut-off level including
cleaning of reinforcement and removal of dismantled materials, etc. for
providing pile caps as directed by Engineer and as per specification.
26 As Per Attached Specification Sheet
A) 1.2 DIA
Chipping and dressing of the RCC piles upto cut-off level B) 1.5 DIA
27 As Per Attached Specification Sheet
Performing Integrity Test (low strain) on all vertical pile. The item shall
include chipping of weak concrete at the top of pile, leveling, bending of
reinforcing bars, preparation of pile head including testing with pile driving
analyser or approved equivalent. To be carried out at least 15 days after
concreting of piles. A specialist approved Agency shall be employed by the
30 Contractor for the test. The test shall be carried out as per relevant ASTM As Per Attached Specification Sheet
code. The item is including complete testing with approved apparatus,
analysis of results and conclusions including submission of test reports in
three hard copies with soft copy in CD.
Carrying out High strain Dynamic Test on any working pile / Test pile as
selected by the Engineer-in-charge. The test shall be carried out by
agency approved by engineer in charge as per IRC-Notification 54 and
31 submitting results /reports in three hard copies with soft copy in CD. Item As Per Attached Specification Sheet
includes all necessary arrangements required for the test. (With guided
frame arrangement)
Performing Integrity Test using cross hole sonic logging on pile. The
item shall include chipping of weak concrete at the top of pile, leveling,
bending of reinforcing bars, preparation of pile head including testing. To
be carried out at least 15 days after concreting of piles. A specialist
approved Agency shall be employed by the Contractor for the test. The
test shall be carried out as per relevant ASTM code D6760. The item is
including complete testing with approved apparatus, analysis of results and
conclusions including submission of test reports in three hard copies
32 alognwith soft copy. Payment shall be made for number of pile tested. As Per Attached Specification Sheet
Rate shall include providing of A class MS steel pipes of 50mm outer
diameter (four numbers and upto foundation level of pile) as per technical
specifications, 2.9mm thick (light) as per IS:1239 in pile at time of casting
to be used for cross hole sonic test. Pipe shall extend from ground level to
bottom of pile where pipe shall be sealed at bottom. Rate shall also include
filling of tubes after sonic test using standard cement non-shrink mortar
before casting of pile cap.
Excavation for pile caps, foundation of columns, approach slab, solid slab,
pile cap beam, Staircase Foundation trial pit for investigation of existing
utility line etc. in all categories of soils, such as sand, clay, murrum, gravel,
pebble, boulder, cobble, soft rock, road crust etc. as per specification for
depth below ground level as mention. Including to pay stacking of
excavated stuff as directed by EIC. The rate is inclusive of contractor's
own machinery and equipment, labour, taxes, temporary works,
consumables, lead & lift, shoring, strutting, timbering and buttressing with MORT&H fifth revision Clause-304
33 sand / clay bags and all such measures necessary to retain in position the As Per Attached Specification Sheet & CPWD clause no. 2.0, 2.1, 2.2,
sides of foundation pit and including backfilling the approved excavated 2.3
soil, clearing and carting/ disposal of excess excavated earth for all lead
and lift. The rate is also inclusive of dewatering by manual or mechanical
means, if required.
a) Soils of all types up to 3.0 m depth including ordinary earth, sand
dry/ wet soil, marine clay, boulders, kankars, soft murrum, hard
murrum, etc.
Providing and applying Coal Tar Epoxy protective paint in two coats of
DFT 210 microns for foundations / concerete surfaces in contact with soil
43 complete as per specifications and as directed by the Engineer including As Per Attached Specification Sheet
all leads and lifts etc. complete.
Providing and fixing Spherical bearing in position true to line and level
including cost of all materials fixtures preparing surface for receiving
bearing, grouting of sleeves with non shrink high strength grout, load
testing of bearing, transporting and fixing in position including all leads and
49 MORT&H fifth revision Section -2000 & 2004
lifts etc. complete as per approved design and drawings and as directed by
Engineer. Contractor shall submit shop drawing and data sheet of bearing.
Sample shall be approved.
Providing and filling Selected Sand (with f = 300) in layers not exceeding
20 cms including watering, ramming, compaction etc. complete behind
51 retaining walls as per specifications and as directed by the engineer CPWD specification clause no. 2.23.1, 2.23.2
incharge.
Providing and applying one priming coat and two coats of synthetic
enemal paint brushing with even shade and cleaning the surface from
56 dust,dirt etc. to misc. items of super sturcture, all complete and as directed MORT&H fifth revision Clause 502 & 503
by Engineer and as per specification.
Prime coat
Providing and applying primer coat with bitumen emulsion SS1 on
prepared surface of granular Base including clearing of road surface and
60 MORT&H fifth revision Clause 502
spraying primer at the rate of 7.5 kg/10sqm using mechanical means.
Providing and applying Tack Coat with Cationic Bitumen Emulsion RS1
complying with IS:8887. The tack coat shall be applied by a self-propelled
or towed bitumen pressure sprayer, equipped for spraying the material
61 MORT&H fifth revision Clause 503
uniformly at the rate of 2.5Kg/10 Sqmt. No dilution or heating at site of RS1
bitumen emulsion shall be permitted.
Providing and laying average 50mm D.B.M. with B.T. Aggregate as per
MORT&H specification with Bitumen VG-30 Grade for mixing @ 45.00
Kg./MT. ie. 4.5 % by total weight of mix including heating and mixing the
aggregate & asphalt in continuous batch mix plant and transporting to site
and spreading the same by sensor paver finisher & consolidation with
62 vibratory roller including providing all materials equipments, tools & plant, MORT&H fifth revision Clause 507
fire wood, oil, kerosene, labour charges etc. complete using contractor's
own machinery batch mix plant & sensor paver finisher etc. complete. Rate
shall be inclusive of tack coat @ 2.5 kg/10Sqm.
Bituminous Concrete:
Providing and laying average 40 mm thick Bituminous concrete on
existing bituminous surface with Bitumen Grade VG-30 for tack coat at the
rate of 2.5kg/10 smt with mechanical sprayer and using specification
graded machine crushed with 5.40 % bitumen VG-30 grade by Wt. of total
mix as per specification MORTH including mixing of asphalt with B.T.
63 chips in continuous batch mix plant transporting same as by paver MORT&H fifth revision Clause 504
finisher and consolidation the same with pair of 8 tonnes to 10 tonnes
vibratory roller to achieve desire density and including VG-30 grade
bitumen, cost of emulsion, cost of required tools , plants, all machineries,
equipment fire wood , oil, kerosene, charges etc. complete.
Asphalt Painting
Providing & laying surface painting with applying VG-30 grade and
spraying asphalt with spray set fitted on mechanical bouzer using asphalt
64 at the rate of 5.0 Kg./10 Sqm. On B.T. surface incl. cleaning the surface MORT&H fifth revision section 500
and flushing the stone dust at 0.03 cmt/10 smt etc. complete.
Core cutting
Making and wet drilling accurate and clean holes of specified diameter in
RCC walls, slabs, beam or any other RCC member without vibration by
core cutting (diamond drilling) machine of HILTI, ITW/Split including
65 scaffolding, safety majors, disposing the debris, cleaning for all levels/ all As Per Attached Specification Sheet
height, after approval of engineer in charge etc compete. Measurement
will be taken for the depth of holes in running meter for specified diameter.
Holes shall made by authorized agency.
a) holes upto 102mm dia
Core cutting
66 b) from 102 to 200mm dia As Per Attached Specification Sheet
Chemical Anchor:
68 B) 12mm x 150mm As Per Attached Specification Sheet
Re-baring:
Providing material and labour for Drilling/ Cleaning hole and injecting
grouting chemical with the help of dispenser, into a hole of required size as
per manufacturer/ structural consultant's specification and fixing rebar of
the required diameter subsequently. Fixing methodology shall be followed
as per manufacturer’s guidelines. Steel will be paid under relevant item.
69 Manufacture to submit Rebar Depth Calculation based on design loads & As Per Attached Specification Sheet
other parameters as provided by consultant and in accordance with EOTA-
TR-023/029 “guidelines for post installed rebar connections” for approval.
Rate shall be inclusive of all material, labour, necessary scaffolding etc
complete for all floors, all height as directed by engineer in charge.
a) Dia 8mm and depth 120mm
Re-baring:
70 b) Dia 10mm and depth 150mm As Per Attached Specification Sheet
Re-baring:
71 c) Dia 12mm and depth 180mm As Per Attached Specification Sheet
Re-baring:
72 d) Dia 16mm and depth 240mm As Per Attached Specification Sheet
Trap door
Providing, Supplying and fixing metal single shutter/ double shutter trap
door of any shape any size as per drawing made from 2mm MS sheet
including frames, internal framing, having min 50micron powder coating of
73 approved make and shade and required hardware like hinges, allen key, As Per Attached Specification Sheet
pivot, handle, lock etc. Rate shall be inclusive for providing, loading/
unloading, transporting and installation as per engineer in charge.
Contractor shall submit shop drawing for approval.
Extra for providing and fixing FRP form liner system for circular shape
elements i.e. pier, pier cap etc for expose quality fair finish work with
required pattern/ texture as per drawing and directed by engineer in
charge. New mould/ form liner shall be provided by contractor as per
drawing. Quantity of new form liner shall be depend on time limit and
strategy of execution. Before every repetition, form liner/ mould shall be
properly clean and mould release agent shall be applied as per
manufacturer's specification and get approved by engineer in charge. Rate
76 shall be inclusive of FRP mould with its strengthening material. Contractor As Per Attached Specification Sheet
shall prepare shop drawing based on concept drawing and get approved.
Total execution method shall be as per manufacturer's specification and
approved by Architect before start the work. Mock-up shall be carried out
with approved sample as suggested by Architect. Finished area of circular
shape concrete surface (which is casted with FRP mould) shall be
measured for payment. Contractor get prior to approved FRP mould for
repetition. After competition of project FRP form liner/ mould shall be
property of Contactor.
Extra for providing and fixing texture finish FRP form liner system of
Reckli or equivalent for any type of shape elements i.e. pylon etc for
any type of pattern for expose quality fair finish work with required pattern/
texture as per drawing and directed by engineer in charge. New mould/
form liner shall be provided by contractor as per drawing. Quantity of new
form liner shall be depend on time limit and strategy of execution. Before
every repetition, form liner/ mould shall be properly clean and mould
release agent shall be applied as per manufacturer's specification and get
approved by engineer in charge. Rate shall be inclusive of FRP mould with
77 its strengthening material. Contractor shall prepare shop drawing based on As Per Attached Specification Sheet
concept drawing and get approved. Total execution method shall be as per
manufacturer's specification and approved by Architect before start the
work. Mock-up shall be carried out with approved sample as suggested by
Architect. Finished area of concrete surface (which is casted with texture
finished FRP mould) shall be measured for payment. Contractor get prior
to approved FRP mould for repetition. After competition of project FRP
form liner/ mould shall be property of Contactor.
Providing and fixing to wall ceiling and floor 10.0 KgF/Sqcm working
pressure PVC 200mm dia pipes of the following outside diameter, low
81 density, complete with special flange compression type fittings, wall clips As Per Attached Specification Sheet
etc. making good wall ceiling and floor.
Providing and fixing grating in 200mm dia PVC pipe at bottom of pier to
protect from any insects, grabage dump etc as per drawing and as directed
82 As Per Attached Specification Sheet
by engineer in charge.
Providing and laying weep holes in abutment and return by using PVC
pipes of 100 mm dia. With laying in proper grade and filling with no fine
85 concrete etc complete as per specifications and as directed by engineer in MORT&H fifth revision Section -2706
charge.
Providing and fixing road side delineator of ht. 1200 mm made of M.S
tube size 100 x 80mm having thickness 1.2mm of ht. 900 mm - and
balance 300mm of MS Angle 25 x 25 x 3mm. Having Micro prismatic retro-
reflective panel confirming to IRC 67-2012 type .~V HIP and of size 80mm
x 150mm on both sides as per clause no. 800 of MORT&H. Complete clause no. 800 of MORT&H
87
delineator processed by heat treatment process to makes it resistant to all clause No. 806 of MORT&H specification 5th revision 2013
weather effects fixed in C.C. '1:2:4 block size of 300 x 300 x 450mm. as
clause No. 806 of MORT&H specification 5th revision 2013.
Providing & Installing Cable Monitoring System for Cable Stayed Bridge
area. System should be for 6 cables, one system for central deck and 2
pair of system for Pylon. Optimum system should be provided for
measuring & monitoring basic structural parameters like Strength, Stress,
Deflection etc of cables, deflection of central deck and pylon however
90 As Per Attached Specification Sheet
advance approval from EIC to be taken for finalization of entire system.
Contractor shall prepare and submit shop drawing as per client’s
requirement. Item shall execute only after prior approval of Engineer in
charge and as per approved shop drawing.
Box cutting the road surface in all sorts of soil, murrum to proper slope &
camber for making a base for road work including removing the excavated
91 stuff & depositing on the road side as R & B general specification for Road Work item No – 9, Page 23.
directed upto any lead any lift.
Extra for Providing and fixing formwork for fair finish exposed concrete
surfaces (vertical or horizontal surface or any shape) for plain fair finish
surface elements for under space elements i.e.toe wall, planter wall etc in
desired pattern and size as per drawing and specifications using film
faced/ laminated shuttering plywood or steel formwork for RCC elements
as specified below including neat cleaning the exposed concrete surface,
rendering (if required), as directed by the engineer-in-charge. Rate shall be
applicable for all levels, all places and all shapes. The contractor shall
submit shuttering pattern/ shop drawing including tie-rod hole position
based on architectural conceptual design with control line. Item shall be
executed only after shuttering pattern approved by Architect/ engineer in
94 charge. Same kind of shuttering material should be only used for standard As Per Attached Specification Sheet
and residual sizes. Concrete surfaces shall be finished smooth fair faced
where indicated as such on the drawings. These areas shall be entirely
free from honey combing, stains, fins, lipping, nail or screw marks, raised
grain marks, air holes or any other imperfections. They shall also be of
even texture throughout. Mock up for all exposed work to be got approved
from architects in all respect prior to concrete production. Architect
reserves right to reject part or all work of sub standard or not in
confirmation to sample approved as per mock up. Contractor shall get prior
approval for reuse the shuttering material for repetition. Shuttering ply shall
be used for only two repetition and steel plate shall be used for seven
repetition.
Providing and laying Brick masonry works in foundation & Plinth using
common burnt clay building bricks confirming to IS 1077-1986 having
crushing strength not less than 35 kg/Sq.cm in cement mortar 1:5 (1
cement : 5 coarse sand) in any shape and all depth upto ground floor level
95 CPWD specifications clause no. 6.2.3, 6.2.4, 6.2.5, 6.2.6, 6.2.7,
including curing, scaffolding racking/ flush jointing etc. complete, as
directed by Engineer in Charge. For all civil, plumbing, electrical &
infrastructure works.
Providing and laying average 20mm thick double coat mala finish
plaster consisting of average 15mm thick wired finished backing coat of
CM 1:4 (1 cement : 4 coarse sand) and average 5- 6mm thick uniform
coat using steel trovel, in CM 1:3 (1 cement : 3 sand) on brickwork / RCC
work at all levels/ all shapes and for all sizes with necessary scaffolding, CPWD specifications clause no. 13.1.1, 13.1.2, . 13.1.4, 13.1.5, 13.1.6,
96 curing, making drip moulds, grooves (at junction of slab & beam, two 13.1.7, 13.1.8, 13.1.9.1, 13.1.9.3, 13.9.5, 13.9.6, 13.1.9.7, 13.1.9.9 ,
different materials like brick & concrete surfaces, periphery of openings, 13.2
below sills, above lintels, above skirting - horizontally or vertically), forming
pattas, closed hacking to RCC surface as per drawing / specifications and
direction of Engineer - in - charge. for all civil, plumbing, electrical &
infrastructure works.
Precast Planter
Supplying, Providing & fixing, hoisting, stacking and arranging in position
Precast Rectangle planter made out of three piece with base (approximate
560mm x 360mm x 80mm) and three ring module (approximate 800mm x
101 As Per Attached Specification Sheet
600mm x 240mm) of approved make, shape and as per approved sample
as per drawing. The rate includes carting upto any lead from store to site
as per directed by engineer in charge.
ACP sheet signage for Road and Bridge on Gantry/ Pole/ cantilever:
Providing, fabricationg and fixing 4 mm thick ACP sign of any shape and
size of approved make to be cut on CNC router cutting and smoothen all
corners and edges. Matter shall be cut in 3M Reflective vinyl and paste on
it as per design and detail and as per manufacturer's specifications. UV
stabilized lamination shall be done on it. The ACP sheet shall be fixed with
SS 304 fastner, screw, clamp, adhesive, tap, etc on any type of MS
structure. Content of sign shall be letters (In Gujarati & English), graphics,
maps, logo, border, etc as per IRC standard in required colour as per
104 design, drawing and approved by Architect and Engineer in charge. Cost of As Per Attached Specification Sheet
MS Structure and Civil works shall be paid as per relevant tender items.
The rate shall also include cost of scaffolding, drilling, fabrication, finishing,
adhesive material etc at all height and all lead. The contractor should
submit the shop drawings based on concept design and do the sampling
and get it approval before mass production. Signage shall be used for
Gantry type signage, Cantilever type signage, road signage (directional,
informetry, cautionary, warning, hazard, Mandatary)
Providing and fixing SS 304 grade powder coated dust bin / litter bin of
capacity 50 Ltr each bin with pole of approved make and as per approved
sample. Dust bin shall be floor mounted with both side pivot for tilting
having stand arrangement. Both bin shall be covered with SS sheet. Dust
bin shall be having chemical resistant, blended with stabilizers, Anti
112 Corrosive, Anti Acidic, Non toxic and free from joints, welds or rims; open As Per Attached Specification Sheet
from either side for easy garbage drop even from distance, Dustbin shall
be as per approved and seperate Dustbin for Dry and wet Waste shallbe
provided (Green and Blue Colour Demarcation on it)
Inauguration plate
Providing and fixing best quality 18-20mm thick mirror polished telephone
black granite for inauguration plate. Granite of required size shall be fixed
with cement mortar on concrete wall/ pylon as per drawing and as directed
by engineer in charge. Exposed edges of granite shall be champhered and
113 As Per Attached Specification Sheet
polishe. Inauguration plate shall contain border, letter/ write-up (in English/
Gujarati/ Hindi Language), graphic, logo of any size, shape or pattern with
engraving and golden paint of approved make and shade.
TREES PLANTATION
Supplying and planting of trees of specified variety in gound surface
including pestisides, termite treatment, and planting of mature plants. Soil
mounts 2' - 3' in size. Tree plantation should be carried on neatly
accurately and with perfection as per drawing and instruction given by the
EIC. Plants shall be planted by manual/ machanical means and rate shall
be inclusive of all material, labour, equipments as per description. Plant
114 must be supply in bag size of 25"X25" or above. Plastic bags or pots As Per Attached Specification Sheet
should be removed carefully and soil around the roots should not be
dropped or disturbed much. Bill shall be placed after completion of
maintenance period but not before stabilizing the hedges. Rates for
mortality to be inclusive. Supporting tripod shall be provided, if required to
make plant in proper vertical position. Work shall be done as shown in the
drawing or as directed and approved by EIC.
Bitumen Cutting
Providing and cutting in bituminous pavement. Cutting to be done with
heavy duty tandom cutting machine consist of diamond blade. Minimum
cutting depth shall be 75 mm from the finished level. Cutting shall be
perfeclty in line. The width and depth of the removal of asphalt towards
kerb stone shall be as per the drawing. Bitumen shall be carefully removed
117 so that the the cutting edge towards the road should not be disturbed. The As Per Attached Specification Sheet
work of removal of the asphalt will be considered in this item as running
meter of the cutting done by machine. One cutting line will be considered
per length of the kerb stone. Bitumen and other debris shall be disposed
for all lead and all lift as per the instruction of the engineer in charge.
Surroundings shall be cleaned to the satisfaction of the engineer in charge.
Providing and fixing rumblers strips of required size with any design
suggested by Architectect/ EIC like bottom design, chequered design, anti
skid pattern specially designed for road grip as per drawing & sample
approved by Architect which is covered with premix bituminous carpet at
119 As Per Attached Specification Sheet
1m centre to centre at approved locations to control speed marked with
white strips of road marking paint etc complete as directed by Engineer in
charge.
ELECTRICAL WORKS
Notes:
1) For more detailed description of any material or item contained in the
BOQ, please refer Electrical Works Specifications. If the detailed specs for
a particular item is not contained in the Part-II technical specification, the
description given in the BOQ shall have to be referred.
120 2) All items mentioned in the tender shall be executed as per the As Per Attached Specification Sheet
instruction and direction of Engineer-in-charge.
Miniature circuit breaker single pole 1A to 32A suitable to operate on 240 V
A.C. system and having breaking capacity 10 KA to be erected in existing
box. confirming to IS 8828/1996 with ISI Mark Cat.III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C
Curve) having 10KA breaking capacity & confirms to IS :8828 in existing
122 As Per Attached Specification Sheet
box having following capacity (a) 6 to 32 Amp. Cat III
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C
Curve) having 10KA breaking capacity & confirms to IS :8828 in existing
123 As Per Attached Specification Sheet
box having following capacity (c) 63 Amp. Cat.III
Approved make Four pole moulded case circuit breaker having breaking
capacity ICU of 35 KA. at 415 V. having Normal current rating up to
200A.with variable Thermal & magnetic release suitable to work on
125 A.C.supply 50 c/s. with all internal connections & complete erected in As Per Attached Specification Sheet
existing 16 G.M.S.housing. ICS=100% of ICU only Cat III
Providing & erecting weather proof, dust & vermin proof, floor mounted
front operated indoor type cubical panel board necessary IP-42 protection
and above as per requirement made from 14 SWG thick CRC M.S. sheet
for outer body & doors, 16 SWG thick CRC M.S.sheet for internal partitions
with necessary supporting angles, flats including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per requirements &
instruction of engineer-in-charge with erection of supplied switch gears,
BUSBARS, with suitable size of inter connecting PVC copper wire / copper-
aluminium strips, rubber grommets, rib, bakelite control fuses for
measuring instruments, earth bus & earth bolts, foundation flange - bolts-
126 base Plates, sufficient nos. of hinged doors, handles with locking As Per Attached Specification Sheet
arrangement and rubber gasket heavy duty end terminal connection
complete. The Panel shall be painted with epoxy powder coating. (The
rates excludes the cost of switchgears, bus bars, inter connecting mains &
Copper Aluminium strips, meters, Fuses etc. The dimension shall be
measured excluding base beams) The panel shall be supplied with
following approved manufacturers with following size. (A) The standard
companies switch gear shall be used and only manufacturers at CPRI
approved factory for beneficial use (i) with 350mm depth
Supplying and erecting triple pole & neutral 440V / 500V panel mounting
Copper Busbars with four equal Nos. of electrolyte bus having current
density not more than 1.6 Amp. / sq.mm (Rated current / cross section
area) duly wrapped with colour insulating tape for phase sequence of
128 following current carrying capacity, erected with necessary bus bar As Per Attached Specification Sheet
supports /insulators, main cable socket to each bar, erected in existing
cubical panel with necessary connections. (A) Suitable for 100 Amp.
Capacity
Supplying & erecting approved make Digital time switch having lithium cell
6 years operative and operate battery backup 1 channel day clock with 14
memory programme, suitable to operate on 240V + 5%, 16A with, floating
contacts Minimum switching setup time 1 minimum & LCD display. Also
132 comprised permanent ON/OFF switching. Programming switches & housed As Per Attached Specification Sheet
in fire proof thermoplastic enclosure & transparent cover erected as
required with necessary connection erected as directed
Supplying & erecting power contactor for time switch complete erected as
133 per direction Cat III [D] 4 pole 440V 40 Amp. As Per Attached Specification Sheet
Providing & erecting L.T. Current Transformer with bar primary 50/5 to
1000/5 ratio 15 VA burden erected in existing CRCA box duly secured with
137 As Per Attached Specification Sheet
insulating materials connected to the meter
Supplying and erecting approved make set of indicator lamps of LED type
lamp, lens cover, Bakelite holder complete erected with necessary
138 As Per Attached Specification Sheet
connections.
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694,
IEC - 227 erected in existing pipe of following size (Specifically for control
139 panel, relays, power switchgears, motor starters & control wiring) with As Per Attached Specification Sheet
required size of copper lugs, nuts and bolts if required. (b) One wire 1.50
sq. mm
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694,
IEC - 227 erected in existing pipe of following size (Specifically for control
140 panel, relays, power switchgears, motor starters & control wiring) with As Per Attached Specification Sheet
required size of copper lugs, nuts and bolts if required. (c) One wire 2.50
sq. mm
Mains with ISI marked, 1.5KV grade electrolyte multi stranded, annealed
copper conductor with heat resistant PVC insulated conforms to IS 694,
IEC - 227 erected in existing pipe of following size (Specifically for control
141 panel, relays, power switchgears, motor starters & control wiring) with As Per Attached Specification Sheet
required size of copper lugs, nuts and bolts if required. (d) One wire 4.00
sq. mm
32 A x 415 V plug & socket with interlocked switched socket, FP MCB and
surface mounting box IP 66 with DIN rail for 5 module equivalent to
legrand make Cat no.56674 but without cost of wiring and piping. Scope
143 As Per Attached Specification Sheet
also includes necessary foundation, cable entry pipes etc complete in all
respect as per drawing.
Covering of cable with second class bricks or cement tiles laid cover the
cable crosswise & also on both sides with covering of 7. 5 Cms. layer of
146 As Per Attached Specification Sheet
sand above & below cable (16 bricks per meter)
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
156 insulating tape etc for following size of cables. As Per Attached Specification Sheet
(B) 3 & 1/2 core 35/50 Sq. mm
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
157 insulating tape etc for following size of cables. (f) 2 to 4 core 25 Sq. mm As Per Attached Specification Sheet
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
158 insulating tape etc for following size of cables. (e) 2 to 4 core 16 Sq. mm As Per Attached Specification Sheet
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
159 insulating tape etc for following size of cables. (d) 2 to 4 core 10 Sq. mm As Per Attached Specification Sheet
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
160 insulating tape etc for following size of cables. (c) 2 to 4 core 6 Sq. mm As Per Attached Specification Sheet
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
161 insulating tape etc for following size of cables. (b) 2 to 4 core 4 Sq. mm As Per Attached Specification Sheet
Providing and erecting ISI mark Medium class RIGID PVC PIPES of
following size complete to be erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed with adhesive solution &
172 As Per Attached Specification Sheet
Clamps with following dia of pipes, in approved manner as directed.
(c) 32 mm
Providing and erecting ISI mark Medium class RIGID PVC PIPES of
following size complete to be erected on/in wall or ceiling erected with
necessary PVC fittings & Junction boxes fixed with adhesive solution &
173 As Per Attached Specification Sheet
Clamps with following dia of pipes, in approved manner as directed. (d) 40
mm
Providing & laying ISI marked Rigid PVC pipe having 6Kg / cm2 (Class-3)
to be erected at road crossing on or floor as directed for laying of cable.
174 The pipes as following size of dia & weight per 6 mtr. As Per Attached Specification Sheet
(B) 50 mm Dia. (2.5Kg/6RMT)
Providing & laying approved make Double walled corrugated pipes (DWC)
of polyethylene(conforming to IS 14930 II )with necessary connecting
accessories of same material at required depth for laying of cable. below
175 ground / road surface for enclosing cable and back filling the same to As Per Attached Specification Sheet
make ground as per original.
120 MM OD DWC Pipe
90 MM OD DWC Pipe
176 As Per Attached Specification Sheet
50 MM OD DWC Pipe
177 As Per Attached Specification Sheet
Supply, erecting,testing, commissioning of 4 Mtr. GI decorative pole
of 165 OD X 4.80 mm thk. With 400 X 12 mm round flange with integral
type junction box with necessasory reducer / coupler for fixing of
light fixtures (post top lantern) & Hinged access door with allen key &
gasket require to access the integral junction box, integrated junction box
having 6 way connector, 1 No. 2A SP MCB with din rail channel, 8mm thk.
Hylem sheet, 12x2 mm thk. GI Patti Clamp, with necessary required
hardware, necessary welding & Fabrication work complete in all respect as
178 per given detail with one coat of zinc oxide complete in all respect as per As Per Attached Specification Sheet
Drawing. Rate shall be including PU paint of shade as per drawing or as
directed by Architect and rate shall be exclusive of foundation work
earthing complete in all respect as per requirement as per site condition
with cost of the chemical grouted Anchor fastener. (Sample to be
approved)
2) Pole Numbering to be carried out by contractor as instructed by Site in
charge as per Client's requirement. (Aprrox Weight 100Kg)
Supply & Installation of GI Pole made out of B CLASS ERW G.I. PIPE
for road having Height - 9.0 metre having thickness of 4.8 mm, 165
mm outer uniform dia., with base plate of 450 x 450 x 16 mm with
stiffener plate with 2 Nos Seprate integral type junction box ( For Street
light & Signage) ,( in existing concrete foundation with necessary
reinforcement ), j bolt, necessary hardware as per detail, with necessary
Reducer / Coupler / for fixing of light fixtures & Hinged access door with
welded chain between pole and hinged door with Allen key require to
access the integral junction box, Fabrication work complete in all respect
as per given detail with one coat of zinc oxide complete in all respect as
180 per Drawing. Rate shall be including two coats of PU paint of shade as per As Per Attached Specification Sheet
drawing or as directed by Architect ( effective length should be 9000mm
above GF) (Sample to be approved )
1) with necessary 2 Nos 6 way connector, 3 Nos. 2A SP MCB with din rail
channel, 8mm thk. Hylem sheet, 12x2 mm thk. GI Patti Clamp, with
necessary required hardware, necessary welding & Fabrication work (if
required) complete in all respect.
2) Pole Numbering to be carried out by contractor as instructed by Site in
charge as per Client's requirement. (Aprrox Weight 210Kg)
“ B ” class Galvanised iron pipe having smooth finished bore of the pipe on
both ends erected nuts and bolts along the pole / wall shaping the pipe as
183 per site requirement. Pipe dia as following. (c ) 40 mm dia. As Per Attached Specification Sheet
Terminal board of size 5.0 x 127 x 152.4 mm.bakelite sheet with 15 Amp.
kitkat pattern porcelain fuse unit with suitable brass studs with nuts,
185 washers and clamps of size 25mm x 3mm suitable for pole painted with As Per Attached Specification Sheet
one coat of red lead paint.