LABORATORY TEST REPORT ON UPVC PROFILE PROVIDED

S.No Test Carried Out IS Code IS Code Result

Requirement

1. Tensile Strength at IS 13360 (Part 6 N/mm2 45 N/mm2

Break 5, Sec 2):

1996

2. Elongation at Break IS 13360 (Part 200 % min 221%

5, Sec 2):

1996

3. Vicat Softening IS 13360 (Part 345.150K min 356.150K

Temperature 6, Sec 1):

1999

4. Hardness (Shored) IS 13360 (Part 70 min 78

5, Sec 11):

1992

5. Density IS 13360 (Part 0.51 - 0.59 1.45 gm/cc

3, Sec 1): gm/cc

1995

6. Heat Reversion IS 13360 shall not be > 0.30%

(Appendix A) 2

7. Heat Ageing IS 13360 No bubble or No crack,


EE Engineering Construction Services
An ISO 9001:2000 Certified Company

(Appendix B) crack shall damage

appear observed

8. Resistance to Impact IS 13360 Shall not No puncture or

by falling mass (Appendix C) damage or damage

puncture observed

9. Impact Strength IS 13360 (Part Shall be 6 18.5 KJ/mm2

5, Sec 5): KJ/mm2 min

1996

10. Colour Fastness IS 13360 Shall be min Better than

(Appendix D) 4. on grey grey scale No.4

scale

11. Impact Strength after IS 13360 Shall be 16.8 KJ/mm2

exposure to artificial (Appendix E) min.70% of

ageing original value