Command Module

Integrated System Control—Monitor and program Key Features:


your network of smoke detection devices.
• Network control of 127
detectors.
The AIR-Intelligence Command Module provides a single location display, control and
• RS-485 communications
interfacing option for systems of up to 127 detectors. The Command Module allows
built in as standard for
global programming of all detector functions simultaneously. The integral bargraph
networking and remote
automatically displays the status of the detector with the highest alarm level to identify
communications.
potential problem areas.
• Built-in Short Isolators for
Contact Monitors enable detectors from alternative manufacturers to be monitored where
optimum reliability.
necessary ensuring optimum flexibility for the end user. The PIN protected programmer
enables global entry of all detector settings to significantly reduce commissioning time. • Integral Serial Interface
programmable for TAP text
The Command Module is fully compatible with all AIR-Intelligence detectors and devices
messages/paging or BACnet
such as the Remote Display Unit for interconnection of large quantities of AIR-Intelligence
BMS communications.
detection devices.
• RS-232 serial interface for
SenseNET PC Graphical
Management System.

Options Available: PC Remote


Software
• Internal detector option
• 19” Rack mounting version All AIR-Intelligence detectors
are supplied with PC remote
• Addressable Protocol Interface software, permitting easy
Cards (APIC) available for system configuration, viewing
popular industry signaling line of event log, diagnostic
circuit protocols. checking of system and the
ability to view ClassiFire
Approvals Artificial Intelligence in real-
time.
Approved/listed by cULus and
FM. Other major North American
certification agency approvals in
process.
Command Module
Networking Applications
• Aircraft Hangars
• Airport Terminals
• Anti-Smoking Enforcement
• Atria
• Cable Tunnels
• Ceiling Voids & Raised Floors
• Cleanrooms
• Coal Conveyers
• Computer Cabinets
• Computer Rooms
• Corrections Facilities
• Electronic Data Processing
(EDP) Centers
Specifications • Engine Rooms
Model Number Command Module • Escalators
Bar-graph Segments 26 • Flour Mills
Maximum Number of Detectors 127 • Food Preparation Areas
Maximum Number of RDUs 500 • Freezer Warehouses

Cable Entries Six (6) top, Six (6) rear • Heritage Buildings

One (1) RS-232 external • High-End Residential


One (1) RS-232 internal • Hospitals
Interfaces
Two (2) RS-485 (data bus in & out) • Hotel Lobbies
Two (2) APIC Addressable Loop (loop in & out)
• Metro Tunnels
One (1) N.O. Fire-1
• Museums
One (1) N.O. Fire-2
Relay Outputs One (1) N.O. Pre Alarm • Paper Mills
One (1) N.O. Auxiliary • Record Storage Facilities
One (1) N.C. Fault • Recycling Centers
Front panel, PC Local (RS-232) or PC Remote • Semiconductor Fabrication
Programming
(RS-485 / TCIP) • Telecommunications Facilities
Supported Languages English, French, German, Spanish and Swedish • Textile Areas
Network Data Bus RS-485 • Tobacco Plants
Maximum Data Bus Length 4,000 ft. between detectors • Warehouses and Distribution
Supply Voltage 21.6V - 26.4 VDC Centers
Current Consumption 250 mA @ 24 VDC • Wood Recycling
ANSI/UL 268: 14° to 100°F (-10° to 38°C)
Operating Temperature Range
CEA 4022: 14° to 140°F (-10° to 60°C)
Weight 11.5 lbs (5.2 kg)
16.8”W x 14.6”H x 3.7”D
Size
427 mm x 372 mm x 95 mm
Operating Humidity Range 0 - 90% (non-condensing)
Enclosure Protection IP-50

USA: Mebane, NC www.edwardsutcfs.com


Canada: Owen Sound, ON www.chubbedwards.com © 2013 UTC Climate Controls & Security.
E--005 Rev. AB
AIR-Intelligence, ClassiFire, LDD 3D3 and SenseNET
are trademarks of UTC Climate Controls & Security. Effective: April 2010