Sie sind auf Seite 1von 16

EQUIPMENT NUMERAL CALCULATOR FOR A SHIP

Based on the Equipment Number and DNV Rules, the minimum required anchoring/mooring
equipment number and specifications are also recommended

Formula
EN = Δ2/3 + 2 B H + 0.1 A
 Δ = Rule Displacement in MT
B = Rule Breadth in m
H = effective height in m from the summer load waterline to the top of the uppermost deckhouse, measured as follows:
H = a + Σ hi
a = distance in m from the summer load waterline amidships to the upper deck at side (Freeboard)

hii = height in m on the center line of each tier of houses having a breadth greater than B/4.
For the lowest tier, hii shall be measured at center line from the upper deck,
or from a notional deck line where there is local discontinuity in the upper deck

References
1. DNV Rules for Classification of Ships (New building) - Part 3 Chapter 3, Section 3 Anchoring and Mooring Equipment 
Table 1: Vessel Inputs
INPUT PARAMETER Symbol Value Units
Displacement (Molded) Δ 3333 MT
Length on Waterline at Summer Loadline LWL 67.9 m
Length Between Perpendilars LBP 66.8 m
Breadth (Molded) B 16 m
Depth (Molded) D 7 m
Summer Loadline Draft d 5.8 m
Fiig 1: Deck House Height Fiig 2:: Bullwarks wiith heiight > 1..5 m
(shaded area to be added)

Table 2: HEIGHT AND AREAS O DECKHOUSES AND SUPERSTRUCTURES

Profile
Effective
Length (Li), m Area Default
Height (hi), m
=(hi x Li)(m)2

DECKHOUSE 10.81 12.58 135.9898


BULLWARK 2 3.59 7.1876
TOTAL 12.81 143.1774

EQUIPMENT NUMBER CALCULATION


Input parameter Symbol Value
Displacement (molded) Breadth (molded) Δ 3333
Breadth B 16
Rule Length L 65.184
Freeboard from Summer Load line a 1.2
Summation of heights of deckhouses Σh 12.81

Effective Height from Summer Loadline to top of Deckhouses H 14.01

Profile area of Hull AH 78.2208

Profile area of Superstructures and Deckhouses AS 143.1774

Profile area of Superstructures and A 221.3982


EQUIPMENT NUMBER
694

Equipment Number selection from Table 1 of DNVGL-RU-SHIP-Pt3Ch11. Edition October

Stockless Stud-link chain cables Towline (guidance) Mooring lines 1)


(guidance)
bower anchors

Total Diameter and Steel or fibre ropes Steel or


length steel grade fibre
Number

m VL K1 VL K2 VL K3 Minimum Minimum Number Length


mm mm mm length breaking of each
Equip- Mass per m strength m
Equipment ment anchor kN
number letter kg
400 to 449 2 1290 385 36 32 28 180 250 4 140

mno
450 to 499 mno 2 1440 412.5 38 34 30 180 277 4 140

500 to 549 2 1590 412.5 40 34 30 190 306 4 160

550 to 599 2 1740 440 42 36 32 190 338 4 160

600 to 659 pqr 2 1920 440 44 38 34 190 371 4 160

660 to 719 2 2100 440 46 40 36 190 406 4 160

720 to 779 2 2280 467.5 48 42 36 190 441 4 170

780 to 839 stu 2 2460 467.5 50 44 38 190 480 4 170

840 to 909 2 2640 467.5 52 46 40 190 518 4 170

910 to 979 2 2850 495 54 48 42 190 559 4 170

980 to 1059 vwx 2 3060 495 56 50 44 200 603 4 180

1060 to 1139 2 3300 495 58 50 46 200 647 4 180

1140 to 1219 2 3540 522.5 60 52 46 200 691 4 180

1220 to 1299 yzA 2 3780 522.5 62 54 48 200 738 4 180

1300 to 1389 2 4050 522.5 64 56 50 200 786 4 180

1390 to 1479 2 4320 550 66 58 50 200 836 4 180

1480 to 1569 BCD 2 4590 550 68 60 52 220 888 5 190

1570 to 1669 2 4890 550 70 62 54 220 941 5 190

1670 to 1789 2 5250 577.5 73 64 56 220 1024 5 190


EFG
1790 to 1929 2 5610 577.5 76 66 58 220 1109 5 190
1930 to 2079 2 6000 577.5 78 68 60 220 1168 5 190
2080 to 2229 2 6450 605 81 70 62 240 1259 5 200

2230 to 2379 HIJ 2 6900 605 84 73 64 240 1356 5 200

2380 to 2529 2 7350 605 87 76 66 240 1453 5 200

2530 to 2699 2 7800 632.5 90 78 68 260 1471 6 200

2700 to 2869 KLM 2 8300 632.5 92 81 70 260 1471 6 200

2870 to 3039 2 8700 632.5 95 84 73 260 1471 6 200

3040 to 3209 2 9300 660 97 84 76 280 1471 6 200

3210 to 3399 NOP 2 9900 660 100 87 78 280 1471 6 200

3400 to 3599 2 10500 660 102 90 78 280 1471 6 200


measured as follows:

Mooring Equipment 
Units
MT
m
m
m
m
m
S

Profile
Area Default
=(hi x Li)(m)2

135.9898
7.1876
143.1774
ng lines 1)
(guidance)

ropes

Minimum
breaking
strength
kN

98
108

123

132

147

157

172

186

201

216

230

250

270

284

309

324

324

333

353
378
402
422

451

480

480

490

500

520

554

588
Project Spreadsheets to BS 8110
Client Advisory Group Made by
Location Level -1 Base B1 Single column RMW
PAD FOUNDATION DESIGN to BS 8110: base Checked
Originated from RCC81.xls on CD © 1999 BCA for RCC chg

A. Design Parameters:
Concrete Density = 0.00 Mpa
Concrete Strength = 0.00 Mpa
Steel Yield Strength =
Water Density =
Concrete Cover =

B. BLOCK GEOMETRY
Length = 3.00 m
Breadth = 2.00 m
Depth = 2.00 m

C. DESIGN LOAD:
Max Tension in M cable = 157.00 kN
Equiment Number =

D. DESIGN LOAD:
Date Page
26-Nov-99 113
Revision Job No
- R68