Construction (Design and Management) Regulations

Design risk assessments are carried out throughout the design stage of this project in accordance with company
procedures and manuals. Where reasonably possible all areas of risk applicable to design and end use of the
construction have been identified and then eliminated, mitigated or recorded as a residual risk. Note that general
risks of which a competent designer or contractor should be aware are not included. This drawing is to be read in
conjunction with the Pre-construction Information and all related documents prepared in accordance with the current
Construction (Design and Management) Regulations 2015 and all applicable Health and Safety legislation as
currently amended.

Wall Type No: W01 Acoustic Rating: 45dB Fire Rating: FR30 mins Wall Type No: W02/W02* Acoustic Rating: 45dB Fire Rating: FR30 mins Wall Type No: W03 Acoustic Rating: -/- Fire Rating: -/- mins Wall Type No: W04 Acoustic Rating: 45dB Fire Rating: FR30 mins
Description: Main flat internal wall, achieves 51dB

Single layer of 15mm thick Knauf Soundshield


Single layer of 15mm thick Knauf Soundshield Plus, taped joints, 3mm plaster skim finish Skimmed and painted wall finish
Plus, taped joints, 3mm plaster skim finish
Single layer of 15mm thick Knauf Soundshield
Plus, taped joints, 3mm plaster skim finish
10mm Dab zone
Blockwork, 100mm
70mm (0.55) Knauf ‘C’ Studs, @600mm
70mm (0.55) Knauf ‘C’ Studs, @600mm
centres
centres
Blockwork, 100mm

Skimmed and painted wall finish

Single layer of 15mm thick Knauf Soundshield


Plus, taped joints, 3mm plaster skim finish

Wall type W02* - 70mm studs to be replaced py 50mm studs and should have two layers of plasterboard. Partition
type mostly used to enclose columns and ofset plasterboard in external walls to allow for a flush finish.
In wet areas replace 15mm Soundshield Plus with 15mm Performance Plus; In wet areas replace 15mm Soundshield Plus with 15mm Performance Plus;

Wall Type No: W05 Acoustic Rating: 45dB Fire Rating: FR30 mins Wall Type No: W06 Acoustic Rating: -/- Fire Rating: -/- mins Wall Type No: W07 Acoustic Rating: -/- Fire Rating: FR60 mins Wall Type No: W08 Acoustic Rating: -/- Fire Rating: -/- mins
Description: Cascading flue riser enclosing wall

Single layer of 15mm thick Knauf Soundshield


Single layer of 15mm thick Knauf Soundshield Plus, taped joints, 3mm plaster skim finish
Knauf Fire Panel, 12.5mm Plus, taped joints, 3mm plaster skim finish

Knauf Fire Panel, 12.5mm 10mm Dab zone Single layer of 15mm thick Knauf Soundshield 10mm Dab zone
Plus, taped joints, 3mm plaster skim finish

60mm Knauf ‘C-T’ Studs @600mm centres Cast-in-place concrete, 200mm thick, as per
SE drawings Cast-in-place concrete, 200mm thick, as per
SE drawings

19mm Knauf Core Board secured between 10mm Dab zone


studs
10mm Dab zone
Skimmed and painted wall finish

2no. layers of 15mm thick Knauf Soundshield


Plus, staggered joints, taped joints, 3mm
plaster skim finish

C02 Riser wall type amended; Some door sizes increased, 29/03/2018
bathroom partitions populated AB | NM
C01 W01 and W02 two layers of plasterboard reduced to one, 09/02/2018
window openings and dimensions amended, some walls
moved, cupboards added for electrical equipment AB | NM
C00 Wall types amended AB | NM 02/02/2018
T01 Revised Wall Types 24/07/2017
T00 Tender issue 08/06/2017
REV DESCRIPTION | DRAWN BY | CHECKED BY | APPROVED DATE
BY
RIBA PLAN OF WORK 2013 WORKSTAGE LEVEL OF MODEL DEFINITION (LoD)
In wet areas replace the outer layer with 15mm Knauf Performance Plus to which adhesive and Stage 5 - Construction LoD 350 - Coordinated Model
tiles are to be applied
PURPOSE OF ISSUE - SUITABLE FOR ... BS1192 +A1:2015 STATUS
Construction Status D4 - Manufacture

Wall Type No: W09 Acoustic Rating: -/- Fire Rating: -/- mins Wall Type No: W10 Acoustic Rating: -/- Fire Rating: -/- mins Wall Type No: W11 Acoustic Rating: -/- Fire Rating: -/- mins
Description: Riser wall

2no. layers of 15mm thick Knauf Soundshield


Plus, staggered joints, taped joints, 3mm 15mm Knauf Fire Panel
plaster skim finish

2no. layers of 15mm thick Knauf Soundshield


Plus, staggered joints, taped joints, 3mm 70mm (0.55) Knauf ‘C’ Studs, @600mm
plaster skim finish centres
Knauf I Studs, 50mm

Void, 13mm Resilient bars 15mm Knauf Fire Panel

12mm plywood patressing to meet equipment


requirements
70mm (0.55) Knauf ‘C’ Studs, @600mm
centres

15mm Knauf Fire Panel

CARDIFF LONDON WREXHAM


029 2052 8140 0207 138 3560 01978 357 887
www.lawray.co.uk
CLIENT
Laxcon Developments
In wet areas replace the outer layer with 15mm Knauf Performance Plus to which adhesive and
tiles are to be applied
PROJECT TITLE
219 Alexandra Avenue

C02 C02 DRAWING TITLE


Wall type amended Wall type amended Wall Types - Flat walls
Print Date: 29/03/2018 16:28:52

PROJECT No SCALE @ A1
419 1:5
DRAWING No PROJECT - ORIGINATOR - VOLUME - LEVEL - TYPE - ROLE - REVISION
(BS1192:2007 CLASS/NUMBER
+A1:2015)
ALA-LAW-XX-XX-DDT AR-220103 C02
DO NOT SCALE Any discrepancy or query concerning this drawing should be referred to the Architect
Copyright © LAWRAY LIMITED
File Name: C:\_RevitLocal\ALA-LAW-X-X-RVT-AR-000002_Central_aurimasbartkus@lawray.co.uk.rvt Registered Office: Greenmeadow Springs, 1 Cae Gwyrdd, Tongwynlais, CARDIFF CF15 7AB
Reg. Co. No. 2724178, VAT Reg. No. 134 2146 06

Das könnte Ihnen auch gefallen