PRODUCT INFORMATION DISASSEMBLY- AND RE-ASSEMBLY ADVISE
- This product meets the requirements regarding - Remove shaving unit, to prevent damages during repairs.
interference suppression on radio and TV. - Remove the screws A1 (2 x).
- After the product has been repaired, it should function - Remove cover. (see Fig. 1)
properly and has to meet the safety requirements as - To remove the trimmer, first
officially laid down at this moment. disassemble the trimmer slide
by pushing down the locking
TECHNICAL INFORMATION pegs (2 x “X” in exploded
view) and move the slide
- Voltage : 100-240 V 50/60 Hz slightly outwards.
- Power consumption : Motor depending - Make room between trimmer
- Motor voltage : 54 V and cover with a small screw-
- Power system : Mains driver (“Y” in exploded view).
- Shaving heads : HQ4 - 4222 036 05450 - Remove screws B1 (2 x).
- SAP coding : HQ5426 - The PC-board with motor
Fig. 1
and hairchamber can now be
removed from the housing.
- Detach the motor clamping springs (item 16) on the
bearing block with a small screwdriver.
REPAIR INSTRUCTION
- No specific issues
OPTIONAL (accessories)
- Pouch - 4222 036 05570