FOUNDATIONS NAILING SCHEDULE ABBREVIATIONS TRUSS NOTES

1. BOTTOMS OF ALL FOUNDATIONS SHALL BE LEVEL. CHANGES IN BOTTOM OF ALL NAILS FOR STRUCTURAL WORK SHALL BE COMMON WIRE NAILS CONFORMING TO THE AB ........... ANCHOR BOLT DESIGN LOADS:
FOUNDATION ELEVATION SHALL BE MADE ACCORDING TO STEPPED FOOTING DETAIL FOLLOWING MINIMUM SIZES: BTWN ....... BETWEEN
ON THE TYPICAL DETAIL SHEET. 1 CC ........... CENTER TO CENTER TOP CHORD
2. ALL PILE CAPS, GRADE BEAMS, TIE BEAMS & OTHER FOOTINGS SHALL BE FORMED 8D 0.131"DIA.X2-12" CJ ........... CONSTRUCTION JOINT 14 PSF DL
UNLESS SPECIFICALLY APPROVED BY THE ENGINEER OF RECORD. FOUNDATIONS MAY 10D 0.148"DIA.X3" CJT .......... CONTROL JOINT 20 PSF LL (REDUCIBLE)
BE CAST IN NEAT EXCAVATIONS PROVIDED WRITTEN APPROVAL IS OBTAINED AND 10D SHORTS 0.148"DIA.X1-5 8" PLUS THICKNESS OF S.P. CLR ......... CLEAR 1
FOOTINGS ARE INCREASED 2" IN WIDTH. USE 2X12 PLANK AT EDGE OF EXCAVATION 16D 0.162"DIA.X3-12" 1 CONC ...... CONCRETE BOTTOM CHORD
TO PROTECT AGAINST SLUFFING, AS REQUIRED. 20D 0.192"DIA.X4" CONTIN .... CONTINUOUS 10 PSF DL
3. WORK PERFORMED ON FOUNDATION SHALL BE DONE IN ACCORDANCE WITH THE CP ........... COMPLETE PENETRATION 10 PSF LL (NON-CONCURRANT W/ TOP CHORD LL)
REQUIREMENTS OF THE CURRENT CBC HOLES SHALL BE SUB-DRILLED WHERE NECESSARY TO PREVENT SPLITTING. NAILING NOT DF ........... DOUGLAS FIR
4. REFER TO SOILS REPORT BY ENGEO FOR ADDITIONAL FOUNDATION REQUIREMENTS. NOTED BELOW OR ON PLANS SHALL BE MINIMUM OF NAILS AT EACH CONTACT. DL ........... DEAD LOAD 1. TOP CHORD TO BE MINIMUM 2X4 TYPICAL - 2X4 ALL OTHER MEMBERS (U.N.O.).
REPORT DATED JUNE 9, 2004. 8D NAILS FOR 1" MATERIAL AND 16D NAILS FOR 2" MATERIAL. (E) ........... EXISTING 2. TRUSS MEMBERS SHALL BE DOUGLAS FIR (DF) NO.2 OR BETTER.
2X12 2X12 EJ ............ EXPANSION JOINT 3. WOOD UNDER PLATES MUST BE FREE OF KNOTS, KNOT HOLES AND GREATLY DISTORTED GRAINS.
1. JOISTS TO SILL OR GIRDER, TOENAIL--------------------------------------------------- 3-8D EN ........... EDGE NAILING 4. CALCULATIONS AND TRUSS DRAWINGS SHALL BE SUBMITTED TO THE ARCHITECT AND/OR ENGINEER FOR
1X8 REVIEW PRIOR TO FABRICATION. GIRDER TRUSSES CALCULATIONS SHALL INCLUDE POINT LOADS FROM
2. BRIDGING TO JOISTS, TOENAIL EACH END--------------------------------------------- 2-8D FB ........... FACE OF BLOCK
3. 1"X6" SUBFLOOR OR LESS TO EACH JOIST, FACE NAIL------------------------------ 2-8D FC ........... FACE OF CONCRETE CARRIER TRUSS REACTIONS. ALL CALCULATIONS SHALL BE SIGNED BY A CIVIL ENGINEER REGISTERED IN
FOOTING FF ........... FINISH FLOOR THE STATE OF CALIFORNIA. 1
WIDTH +2"
4. WIDER THAN 1"X6" SUBFLOOR TO EACH JOIST, FACE NAIL------------------------- 3-8D
5. 2" SUBFLOOR TO JOIST OR GIRDER, BLIND & FACE NAIL-------------------------- 2-16D FLR .......... FLOOR 5. FABRICATION AND DESIGN SHALL CONFORM TO THE ICBO, CURRENT EDITION AND TPI-85 OF THE TRUSS
6. SOLE PLATE TO JOIST OR BLOCKING, TYPICAL FACE NAIL-------------- 16D @ 16"O.C. FS ........... FACE OF STUD PLATE INSTITUTE.
7. SOLE PLATE TO JOIST BLOCKING, AT BRACED WALL PANEL------------ 3-16D PER 16" FTG ......... FOOTING 6. PROVIDE TEMPORARY ERECTION BRACING AS REQUIRED.
CONCRETE 1
8. TOP PLATE TO STUD, END NAIL--------------------------------------------------------- 4-16D GA ........... GAUGE 7. ALLOWABLE STRESS INCREASE FOR LOAD DURATION SHALL BE 25% (PERCENT) MAXIMUM.
9. STUD TO SOLE PLATE------------------------------- 6-8D, TOENAIL OR 4-16D, END NAIL GLB ......... GLUED-LAMINATED BEAM 8. INCREASE FOR ALLOWABLE STRESSES FOR REPETITIVE MEMBERS, SHALL BE PERMISSIBLE.
1. CONCRETE 28 DAY COMPRESSIVE STRENGTH, F'C = 3,000PSI, U.N.O.
10. DOUBLE STUDS, FACE NAIL------------------------------------------------- 16D @ 24" O.C. HDR ......... HEADER 9. EFFECTS OF ECCENTRIC LOADING SHALL BE CONSIDERED IN THE DESIGN OF ALL JOINTS.
2. WATER TO CEMENT RATIO SHALL NOT EXCEED 0.50.
11. DOUBLE TOP PLATES, TYPICAL FACE NAIL-------------------------------- 16D @ 16" O.C. HSB ......... HIGH STRENGTH BOLT (A-325) 10. GENERAL CONTRACTOR TO PROVIDE WEB BRACING AS REQUIRED BY TRUSS MANUFACTURERS DESIGN.
3. MOIST CURE SLABS FOR A MINIMUM OF 3 DAYS.
12. DOUBLE TOP PLATES, LAP SPLICE, U.N.O.-------------------------------------------16-16D HT ........... HEIGHT 11. BUILT-UP GIRDER TRUSSES SHALL BE LAMINATED USING 12" BOLTS AT 24" O.C. MAXIMUM THROUGH ALL
4. CONCRETE MIX DESIGN SHALL BE PREPARED BY A 3RD PARTY INDEPENDENT LABORATORY. SELECTION
13. BLOCKING BETWEEN JOISTS OR RAFTERS TO TOP PLATE, TOENAIL--------------- 3-8D JH ........... JOIST HANGER (SIMPSON) MEMBERS.
OF CONCRETE MIX PROPORTIONS SHALL BE PER THE CALIFORNIA BUILDING CODE.

REVISIONS
14. RIM JOIST TO TOP PLATE, TOENAIL-------------------------------------------- 8D @ 6"O.C. LL ............ LIVE LOAD 12. ALL HARDWARE REQUIRED FOR CONNECTING TRUSSES (JACK TO HIP, HIP TO GIRDER, GIRDER TO GIRDER,
5. CEMENT SHALL CONFORM TO ASTM C-150 TYPE I OR II. 1
15. TOP PLATES, LAPS AND INTERSECTION, FACE NAIL-------------------------------- 2-16D LS ........... LAG SCREW ETC) SHALL BE DESIGNED, DETAILED AND SPECIFIED BY TRUSS FABRICATOR.
6. CONCRETE AGGREGATES SHALL CONFORM TO ASTM C-33. AGGREGATES FOR LIGHTWEIGHT CONCRETE
16. CONTINUOUS HEADER, TWO PIECES, TOENAIL---- 16D @ 16"O.C. ALOG EACH EDGE LSL ......... LAMINATED STRAND LUMBER 13. TRUSS MANUFACTURER SHALL SUBMIT LATEST ICBO APPROVED TEST DATA FOR TRUSS METAL PLATE
SHALL CONFORM TO ASTM C-330.
17. CEILING JOISTS TO PLATE, TOENAIL----------------------------------------------------- 3-8D 2325 Fb, 310 Fv, 1.55E CONNECTIONS TO ARCHITECT AND/OR ENGINEER PRIOR TO FABRICATION.
9. REINFORCING DIMENSIONS SHOWN FOR LOCATION OF REINFORCING ARE TO THE FACE OF MAIN BARS
18. CONTINUOUS HEADER TO STUD, TOENAIL--------------------------------------------- 4-8D LT WT ....... LIGHT WEIGHT 14. TRUSS MANUFACTURER TO PROVIDE PLAN DRAWING SHOWING TRUSS LOCATIONS AND TRUSS PROFILE
AND DENOTE CLEAR COVERAGE. CONCRETE COVERAGE SHALL BE AS FOLLOWS: CONCRETE DEPOSITED

PLAN CHECK COMMENTS - JUNE 13, 2016


19. CEILING JOISTS, LAPS OVER PARTITIONS, FACE NAIL------------------------------ 3-16D LVL .......... LAMINATED VENEER LUMBER SHOP DRAWINGS PRIOR TO FABRICATION.
AGAINST GROUND (EXCEPT SLABS) -3". CONCRETE EXPOSED TO GROUND BUT PLACES IN FORMS -2".
20. CEILING JOISTS TO PARALLEL RAFTERS, FACE NAIL-------------------------------- 3-16D 2600Fb, 285Fv, 1.8E 15. GENERAL CONTRACTOR TO VERIFY ALL DIMENSIONS SHOWN ON TRUSS PROFILES WITH ARCHITECTURAL
SLABS (ON GROUND) -2" CLEAR FROM TOP U.N.O.
21. RAFTER TO PLATE, TOE NAIL-------------------------------------------------------------- 3-8D MFR ......... MANUFACTURER DRAWINGS AND IN FIELD WITH WALL LAYOUT PRIOR TO FABRICATION. PROVIDE SHOP DRAWINGS WITH
10. ALL PREHEATING AND WELDING OF REINFORCING BARS SHALL BE DONE IN ACCORDANCE WITH AWS D1.4
22. 1" BRACE TO EACH STUD & PLATE, FACE NAIL----------------------------------------- 2-8D MI ........... MALLEABLE IRON DIMENSIONS REVIEWED AND APPROVED BY GENERAL CONTRACTOR.
LATEST EDITION AND SHALL BE CONTINUOUSLY INSPECTED BY A QUALIFIED LABORATORY. CONTRACTOR 16. TRUSS MANUFACTURER TO ACCOUNT FOR THE WEIGHT OF ALL MECHANICAL EQUIPMENT IN DESIGN OF ALL
SHALL FURNISH TO THE LABORATORY, REBAR MILL CERTIFICATES. 23. 1"X8" SHEATHING OR LESS TO EACH BEARING---------------------------------------- 3-8D (N) ........... NEW
24. WIDER THAN 1"X8" SHEATHING TO EACH BEARING, FACE NAIL--------------------- 3-8D PTDF ........ PRESSURE TREATED DOUGLAS FIR TRUSSES WHICH SUPPORT SUCH UNITS.
11. REINFORCING STEEL SHALL BE FABRICATED ACCORDING TO "MANUAL OF STANDARD PRACTICE FOR
25. BUILT UP CORNER STUDS--------------------------------------------------- 16D @ 24"O.C. PSL .......... PARALLEL STRAND LUMBER
REINFORCED CONCRETE CONSTRUCTION". 1
26. BUILT UP GIRDER & BEAMS--- 20D @ 32" O.C. AT TOP & BOTTOM AND STAGGERED 2900Fb, 290Fv, 2.0E
12. WIRE FABRIC SHALL CONFORM TO ACI 318-3.5.1, ACI 318-3.5.7, AND ASTM A-1064.
2-20D AT ENDS AT EACH SPLICE NTS ........ NOT TO SCALE 1
13. REINFORCING STEEL SHALL CONFORM TO ASTM A615-GRADE 60 FOR NO. 5 AND LARGER, AND ASTM
OH .......... OPPOSITE HAND
A615-GRADE 40 FOR NO. 4 AND SMALLER, EXCEPT REINFORCING STEEL TO BE WELDED SHALL
CONFORM TO ASTM A706.
27. 2" PLANKS---------------------------------------------------------- 2-16D AT EACH BEARING
28. WOOD STRUCTURAL PANELS: PC ........... PIECE ENGINEERED ITEMS BY OTHERS
1 SUBFLOOR & WALL SHEATHING TO FRAMING PP ........... PARTIAL PENETRATION 1. THE MANUFACTURED TRUSSES CONTAINED IN THESE PLANS SHALL BE DESIGNED BY A LICENSED
14. SPLICES IN CONTINUOUS REINFORCEMENT FOR A CLASS "A" LAP SPLICE FOR NORMAL WEIGHT NAILS SPACED @ 6"O.C.
1 " AND LESS--------------------------------------------------- 6D RDWD ...... REDWOOD PROFESSIONAL AND REVIEWED FOR BUILDING DESIGN COMPLIANCE BY CULLUMBER ENGINEERING. TRUSS
CONCRETE WHERE LESS THAN 12" OF CONCRETE IS BELOW THE LAP SPLICE SHALL BE 48 BAR 2
AT EDGES, 12"O.C. @
19 " - 1"-------------------------------------------------------- 8D SC ........... SHEAR CONNECTOR DESIGN AND ANY REVISED ROOF PLANS SHALL ALSO BE REVIEWED AND APPROVED BY THE ENGINEER OF
DIAMETERS AND SPLICES IN ADJACENT BARS SHALL BE NOT LESS THAN 5'-0" APART. CLASS "B" LAP 32
INTERMEDIATE
1- 18" - 1-14"---------------------------------------------------- 10D SDSTS ..... SELF DRILLING SELF TAPPING SCREW RECORD AND MUST BE SUBMITTED TO BUILDING AUTHORITY AND APPROVED BEFORE TRUSS INSTALLATION.
SPLICES SHALL BE 63 BAR DIAMETERS. SPLICE CONTINUOUS BARS IN SPANDRELS, GRADE BEAMS, ECT., SUPPORTS EXCEPT 6" AT
COMBINATION SUBFLOOR UNDERLAYMENT TO FRAMING SP ........... STRUCTURAL PLYWOOD

NO.
AS FOLLOWS: TOP BARS AT MID-SPAN; BOTTOM BARS AT CENTERLINE AT SUPPORT, UNLESS NOTED ALL SUPPORTS WHERE

1
3 " - 1"--------------------------------------------------------- 8D SPEN ........ STRUCTURAL PLYWOOD EDGE NAILING
OTHERWISE. SPLICES IN WWF SHALL BE 1.5 MESHES WIDE. 4
SPANS ARE 48" OR
1- 18" - 1- 14"--------------------------------------------------- 10D STFNR ...... STIFFENER
15. REINFORCING, DOWELS, BOLTS, ANCHORS, SLEEVES, ETC., TO BE EMBEDDED IN CONCRETE SHALL BE
TIED SECURELY IN POSITION BEFORE PLACING CONCRETE PER ACI 318-12.18. 29. PANEL SIDING TO FRAMING
MORE. FOR NAILING OF
BRACED WALL PANELS
STGGRD ... STAGGERED SPECIAL INSPECTION
1 " OR LESS---------------------------------------------------- 6D
2
T&B .......... TOP & BOTTOM 1. THIS PROJECT WILL REQUIRE SPECIAL INSPECTION PER SECTION 1705 OF THE 2013 CBC. THE
16. CONSTRUCTION JOINTS SHALL BE MADE ROUGH AND SURFACE FREE OF LOOSE DEBRIS. CONCRETE MY OR SHEAR WALLS, SEE
5 "--------------------------------------------------------------- 8D
8
T&G .......... TONGUE & GROOVE OWNER IS REQUIRED TO CONTRACT WITH A QUALIFIED AND REGIONALLY APPROVED SPECIAL INSPECTION
BE ROUGHENED BY SAND BLASTING OR CHIPPING THE ENTIRE SURFACE TO PRODUCE 14" DEEP PLAN. TN ........... TOE NAIL AGENCY MEETING THE REQUIREMENTS OF CBC 1704A.1. THE OWNER WILL BE RESPONSIBLE FOR

STRUCTURAL NOTES AND SPECIFICATIONS


DEFORMATIONS. TOF ......... TOP OF FRAMING COORDINATING AND SCHEDULING THE SPECIAL INSPECTIONS DURING THE CONSTRUCTION WORK AS
17. REMOVE ALL DEBRIS FROM FORMS BEFORE CASTING ANY CONCRETE.
18. 3'-0" SHALL BE THE MAXIMUM ALLOWED FREE FALL FOR CONCRETE TO MORE CLOSELY CONFORM TO ACI
GENERAL CONSTRUCTION NOTES: TOS ......... TOP OF STEAL REQUIRED PER THE BELOW TABLE. OWNER IS TO PROVIDE BUILDING DEPARTMENT WITH REQUIRED
1. THE INFORMATION ON THIS SET OF CONSTRUCTION DOCUMENT IS RELATED TO UNO ......... UNLESS NOTED OTHERWISE NOTIFICATIONS UPON COMPLETION OF SPECIAL INSPECTION WITH DOCUMENTATION FROM THE SPECIAL
318-5.10. W/ ........... WITH

(PLAN-2554) STATE HIGHWAY 104


1 THE BASIC DESIGN INTENT AND FRAMING DETAILS. THEY ARE INTENDED AS A INSPECTION AGENCY. ENGINEER OF RECORD IS TO BE NOTIFIED IF ANY VARIATIONS TO PLANS HAVE BEEN
19. CONSOLIDATE CONCRETE PLACED IN FORMS BY MECHANICAL VIBRATING EQUIPMENT SUPPLEMENTED BY W/O ......... WITHOUT
HAND-SPADING, RODDING OR TAMPING. USE EQUIPMENT AND PROCEDURES FOR CONSOLIDATION OF CONSTRUCTION AID, NOT A SUBSTITUTE FOR GENERALLY ACCEPTED GOOD DONE DURING THE CONSTRUCTION PROCESS.
BUILDING PRACTICES AND COMPLIANCE WITH CURRENT CALIFORNIA STATE WP .......... WORK POINT
CONCRETE IN ACCORDANCE WITH THE RECOMMENDED PRACTICES OF ACI 309 TO SUIT THE TYPE OF WS .......... WOOD SCREW
CONCRETE AND PROJECT CONDITIONS. BUILDING CODES. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR PROVIDING 2. PERIODIC SPECIAL INSPECTION SHALL BE REQUIRED FOR ANY SHEARWALLS TYPE "3" OR HIGHER
WWF ........ WELDED WIRE FABRIC

SACRAMENTO, CA 95815
20. NO WOOD SPREADERS ALLOWED. NO WOOD STAKES ALLOWED IN AREAS TO BE CONCRETED. STANDARD CONSTRUCTION DETAILS AND PROCEDURES TO ENSURE A WHERE FASTENER SPACING IS MORE THAN 4" PER SECTION 1705.10.1 OF THE 2013 CBC. SHEARWALL
PROFESSIONALLY FINISHED, STRUCTURALLY SOUND, AND WEATHERPROOF ............ CENTERLINE TYPES "1" AND "2" SHALL NOT BE REQUIRED TO BE SPECIAL INSPECTED.
21. ALL SAW CUTTING SHALL BE DONE AFTER INITIAL SET HAS OCCURRED TO AVOID TEARING OR DAMAGE ............ PLATE
BY THE SWABBED, BUT BEFORE INITIAL SHRINKING HAS OCCURRED. COMPLETED PROJECT.
2. THE GENERAL CONTRACTOR IS RESPONSIBLE FOR ENSURING THAT ALL WORK #CL ............ NUMBER OF POUNDS
22. DRILL THROUGH STEEL COLUMNS, BEAMS AND PLATES TO PASS CONTINUOUS REINFORCING. ⍁PL ............. SQUARE
23. ADDITIONAL REINFORCING IN PRECAST OR TILT-UP PANELS REQUIRED FOR LIFTING STRESSES SHALL BE AND CONSTRUCTION MEETS ALL CURRENT FEDERAL, STATE, COUNTY, AND
LOCAL CODES, ORDINANCES, REGULATIONS, ETC. THESE CODES ARE TO BE Ø ............ ROUND OR DIAMETER REFERENCED
SUPPLIED BY THE CONTRACTOR. ......... CONTINUOUS WOOD IN SECTION VERIFICATION AND INSPECTION CONTINUOUS PERIODIC
24. PROVIDE 2-NO.5X4'-0" DIAGONAL REINFORCING AT MID-DEPTH OF SLAB AT ALL REENTRANT CORNERS CONSIDERED PART OF THE SPECIFICATIONS FOR THIS BUILDING AND SHOULD STANDARD
BE ADHERED TO EVEN IF THEY ARE IN VARIANCE OF THE PLAN. ......... WOOD BLOCKING IN SECTION
TYPICAL. ......... END OF WOOD PIECE ACI 318: CH.
3. DIMENSIONS SHALL TAKE PRECEDENCE OVER SCALE DRAWING (DO NOT SCALE 5. VERIFYING USE OF REQUIRED DESIGN MIX. --- X
DRAWING.) 4, 5.2-5.4
WOOD 4. THE ENGINEER HAS NOT BEEN ENGAGED FOR CONSTANT CONSTRUCTION STRUCTURAL INDEX
1 SUPERVISION AND ASSUMES NO RESPONSIBILITY FOR CONSTRUCTION
1. ALL WOOD IN DIRECT CONTACT WITH EARTH OR CONCRETE SHALL BE PRESSURE TREATED SN1 STRUCTURAL NOTES AND SPECIFICATIONS 6. AT THE TIME FRESH CONCRETE IS ASTM C 172,
COORDINATING WITH THESE PLANS, NOR RESPONSIBILITY FOR CONSTRUCTION
DOUGLAS FIR.
MEANS, METHODS, TECHNIQUES, SEQUENCE, OR PROCEDURES, OR FOR
S1.0 FOUNDATION AND LOWER SHEARWALL PLAN SAMPLED TO FABRICATE SPECIMENS FOR ASTM C 31,
2. BEARING AND SHEAR WALLS SHALL HAVE DOUBLE TOP PLATES, LAPPED AT WALL AND PARTITION S2.0 UPPER FLOOR SHEARWALL PLAN STRENGTH TESTS, PERFORM SLUMP AND X ---
INTERSECTION WITH 3-16D NAILS. SAFETY PRECAUTIONS AND PROGRAMS IN CONNECTION WITH THE WORK.
S3.O MAIN FLOOR SHEARWALL PLAN ACI 318:
THERE ARE NO WARRANTIES FOR A SPECIFIC USE EXPRESSED OR IMPLIED IN AIR CONTENT TESTS, AND DETERMINE THE 5.6, 5.8
3. PROVIDE SOLID BLOCKING BETWEEN JOISTS AND RAFTERS AT ALL SUPPORTS. S4.0 FLOOR AND LOWER ROOF FRAMING PLAN
4. PROVIDE BLOCKING AT ALL CEILING LEVELS. 1
THE USE OF THESE PLANS.
S5.0 ROOF FRAMING PLAN - ELEV A
TEMPERATURE OF THE CONCRETE.
5. ALL STRUCTURAL WOOD SHALL CONFORM WITH THE FOLLOWING SPECIFICATION: 5. REFER TO ARCHITECTURAL SHEETS FOR FLOOR PLANS, EXTERIOR ELEVATIONS,
S6.0 ROOF FRAMING PLAN - ELEV B
DOUGLAS FIR - COAST REGION - WCLIB GRADING RULES NO.17 DF NO.2, U.N.O. AND WINDOW AND DOOR SIZES AND TYPES.
S7.0 ROOF FRAMING PLAN - ELEV C 7. INSPECTION OF CONCRETE AND ACI 318:
REDWOOD - CALIFORNIA REDWOOD ASSOCIATION GRADING RULES, LATEST EDITION. PT1 POST TENSION DETAILS SHOTCRETE PLACEMENT FOR PROPER X --- 5.9, 5.10
GLUED LAMINATED BEAMS - SHALL BE 24F-V4 OR 24F-V8 FOR CANTILEVERED BEAMS. BEAMS
SHALL ALSO BE MANUFACTURED AND IDENTIFIED AS REQUIRED IN ANSI/AITC A190.1 AND
GENERAL COMMENT: SD1
SD2
STRUCTURAL DETAILS
STRUCTURAL DETAILS
APPLICATION TECHNIQUES.
ASTM D3737. STANDARD SPEC. FOR STRUCTURAL GLUED LAMINATED TIMBER AITC 117 THE NOTES, RECOMMENDATIONS, AND CONSIDERATIONS INCLUDED HEREIN ARE SD3 STRUCTURAL DETAILS
LATEST EDITION. SUBMIT SHOP DRAWINGS PRIOR TO FABRICATION OF GLUED-LAMINATED OFFERED IN GOOD FAITH FOR CONTRACTOR REFERENCE. THESE NOTES ARE NOT 8. INSPECTION FOR MAINTENANCE OF ACI 318:
MEMBERS.
PLYWOOD - U.S. PRODUCT STANDARDS PS1 AND PS2. PLYWOOD SHALL BE APA RATED EXPOSURE
ALL-INCLUSIVE AND DO NOT, BY ANY MEANS, INCLUDE ALL THE INFORMATION
NECESSARY TO COVER ALL ASPECTS OF THE CONSTRUCTION PROJECT. THESE
DESIGN CRITERIA SPECIFIED CURING TEMPERATURE --- X 5.11-5.13
1, OR EXTERIOR, AS REQUIRED; STRUCTURAL 1 AND C-D TO MEET PS1 AND PS2 AS REQUIRED. NOTES ARE SUPERCEDED BY THE CONTRACTOR'S EXPERIENCE, BEST JUDGEMENT, SEISMIC CRITERIA AND TECHNIQUES.
CDX (C-D EXPOSURE 1) OR OSB (ORIENTED STRAND BOARD) @ FLOORS AND ROOF - U.N.O. AND LOCAL ACCEPTABLE BUILDING CODES. THE DRAWINGS, ILLUSTRATIONS, AND SDC D
6. PRESSURE TREATED DOUGLAS FIR - AWPA (AMERICAN WOOD PRESERVERS' ASSOCIATION) U1. DIAGRAMS INCLUDED IN THIS PACKAGE ARE FOR THE DESIGN OF THE BUILDING 1 SITE CLASS D
USE CATEGORY UC2 FOR INTERIOR USE. WATERBORNE PRESERVATIVES SHALL HAVE A MINIMUM AND ARE TO BE USED IN COORDINATION OF THE WORK. THE CONTRACTOR IS RISK CATAGORY II 9. INSPECTION OF PRESTRESSED CONCRETE
RETENTION LEVEL OF 0.25 LB/FT^3 AND SHALL NOT CONTAIN CHROMIUM, COPPER, OR RESPONSIBLE FOR THE INTEGRITY OF ALL ASSEMBLIES AND ALL WORK IS TO SEISMIC IMPORTANCE FACTOR 1.00
RESPONSE MODIFICATION FACTOR 6.5 a. APPLICATION OF PRESTRESSING FORCES. X --- ACI 318:
ARSENATE. NEWLY EXPOSED SURFACES, RESULTING FROM FIELD MODIFICATIONS SUCH AS CONFORM TO ACCEPTED RESIDENTIAL CONSTRUCTION STANDARDS.
CUTTING, BORING, OR HANDLING, SHALL BE FIELD TREATED IN ACCORDANCE WITH AWPA M-4. SEISMIC FORCE RESISTING SYSTEM LIGHT FRAME WOOD SHEAR WALL b. GROUTING OF BONDED PRESTRESSING X 18.20 ACI
318: 18.18.4

PROJECT
7. HOLES FOR BOLTS IN WOOD SHALL BE BORED WITH A BIT OF THE SAME NOMINAL DIAMETER AS TENDONS IN THE SEISMIC
THE BOLT PLUS 116". SHEARWALL NOTES: Ss 0.459g FORCE-RESISTING SYSTEM.

TITLE
8. HOLES FOR LAG SCREW SHALL BE BORED TO THE SAME DIAMETER AND DEPTH AS THE SHANK S1 0.234g
1. MIN 2X FRAMING MEMBERS OR BLOCKING REQUIRED AT ALL PANEL EDGES IN Sds 0.439g
AND THE REST NO LARGER THAN THE ROOT OF THE THREAD. SHEAR WALL.
9. LAG SCREWS AND WOOD SCREWS SHALL BE SCREWED AND NOT DRIVEN INTO PLACE. SOAP MAY Sd1 0.301g SEAL
2. TABLE VALUES ARE BASED ON 16" O.C. STUD SPACING. Cs 0.07g 11. VERIFICATION OF IN-SITU CONCRETE
BE USED TO LUBRICATE THE SCREWS. 3. ALL ANCHOR BOLTS IN WALLS INCLUDING SHEARWALLS REQUIRE 3"x3"x.229"
10. ALL BOLTS AND LAG SCREWS SHALL BE PROVIDED WITH METAL WASHERS UNDER HEADS AND Ωo 3.0 1 STRENGTH, PRIOR TO STRESSING OF
THICK PLATE WASHERS. ONE EDGE OF THE STEEL PLATE WASHER SHALL EXTEND
NUTS WHICH BEAR ON WOOD. APPLIES ALSO TO INSERTED EXPANDING FASTENERS, RED HEAD TO WITHIN 1/2" OF THE MUDSILL ON THE SIDE(S) WITH APA RATED WOOD
Cd 4.0 TENDONS IN POST-TENSIONED CONCRETE --- X ACI 318: 6.2
ECT. ANAYSIS PROCESS EQUIVALENT LATERAL FORCE AND PRIOR TO REMOVAL OF SHORES AND
SHEATHING. THE HOLE IN THE PLATE WASHER IS PERMITTED TO BE DIAGONALLY SEISMIC BASE SHEAR 1.9 KIPS (LEFT TO RIGHT-UPPER)
BOLT DIAMETER MI WASHER STEEL WASHER FORMS FROM BEAMS AND STRUCTURAL
SLOTTED WITH A WIDTH OF UP TO 3/16" (44 mm) LARGER THAN THE BOLT 2.0 KIPS (FRONT TO BACK-UPPER)
1 " DIA.
2
15
2" DIA. X 16" 3" X 3" X 14" DIAMETER AND A SLOT LENGTH NOT TO EXCEED 1 3/4" (44 mm), PROVIDED A SLABS.
4.1 KIPS (LEFT TO RIGHT-MAIN)
5 " DIA.
8 23 4" DIA. X 1516" 3" X 3" X 14" STANDARD CUT WASHER IS PLACED BETWEEN THE PLATE WASHER AND THE NUT. 4.3 KIPS (FRONT TO BACK-MAIN)
3 " DIA.
4 3" DIA. X 716" 3" X 3" X 516" 4. SOLE PLATE NAILING LESS THAN 6" O.C. SHALL BE STAGGERED 1/2" ABOUT THE GRAVITY LOADING
7 " DIA.
8 3 2" DIA. X 16" 312" X 312" X 3 8"
1 7 CENTERLINE OF THE SOLID RIM. ROOF LIVE 20psf 1 12. INSPECT FORMWORK FOR SHAPE,
5. (2) ANCHOR BOLTS MINIMUM PER SHEAR WALL. LOCATION, AND DIMENSIONS OF THE --- X ACI 318:
1" DIA. 4" DIA. X 12" 33 4" X 33 4" X 3 8" ROOF DEAD 14psf
6. 3X and 4X MEMBERS AT ADJOINING PANEL EDGES MUST BE A SINGLE MEMBER. FLOOR LIVE 40psf
1
CONCRETE MEMBER BEING FORMED 6.1.1
7. FOR SHEAR WALLS ON RAISED WOOD, FOUNDATIONS AND UPPER FLOORS
11. ALL BOLTS AND LAG SCREWS SHALL BE TIGHTENED ON INSTALLATION AND RETIGHTENED BEFORE SCALE: AS NOTED
REQUIRING LTP5 CLIPS AT THE 2x SOLE PLATE, A MINIMUM OF (1) CLIPS MUST WIND CRITERIA
CLOSING IN OR AT COMPLETION OF JOB. 17 MAR 2016
ALWAYS BE INSTALLED. ULTIMATE WIND, Vult 110mph DATE:
12. BLOCK SP JOINTS WITH 2X4 FLAT BLOCKING WHERE NOTED ON ROOF OR FLOOR FRAMING PLANS
8. SOLE PLATE TO RIM, OR SOLE PLATE TO BEAM/BLOCKING TO BE 2X U.O.N. BASIC WIND, Vasd 85mph DRAWN BY: S.M.
AND WITH BLOCKING SAME AS STUDS AT WALLS.
9. WHEN A SHEARWALL IS LOCATED IN A FIRE PROTECTED WALL, THE FIELD NAILING WIND EXPOSURE B
13. LAY ALL STRUCTURAL PLYWOOD ON ROOF AND FLOORS WITH FACE GRAIN PERPENDICULAR TO CHECKED BY: W.C.
SHALL BE 8" O.C. MAX REGARDLESS OF THE SHEAR WALL SPECIFICATIONS. INTERNAL PRESSURE COEFF +1-0.18 1
SUPPORT UNLESS NOTED OTHERWISE. 1 EDGE NAILING AND NAIL SIZE SHALL BE THE SAME AS SPECIFIED ON THE PLANS. Iw 1.0 JOB NO.:
14. CONNECTOR HARDWARE MODEL NUMBER ARE THOSE FOR SIMPSON SRONG-TIE COMPANY.
10. DRYWALL SCREWS ARE PERMITTED TO SUBSTITUTE FOR THE 5D AND 6D NAILS.
EQUIVALENT CONNECTORS WITH ICC ACCEPTANCE MAY BE SUBSTITUTED WITH WRITTEN FILE NAME: IONE 2254
11. ALL FIELD NAILING SHALL BE @ 12" O.C. MAX, U.N.O. SOIL BEARING 1500psf
APPROVAL FROM THE ENGINEER OF RECORD. ALL JOIST HANGARS SHALL BE SIMPSON U SERIES
12. FOR SHEARWALL TYPES 3 AND HIGHER, SDS SCREWS AND LTP CLIPS SHALL BE SHEET NO.
UNLESS NOTED OTHERWISE.
USED IN COMBINATION TO PROVIDE THE NECESSARY CAPACITY. CODES
15. FASTENERS FOR PRESERVATIVE TREATED & FIRE RETARDANT TREATED WOOD SHALL DE OF HOP
DIPPED ZINC COATED GALVANIZED STEEL (PER ASTM A153, CLASS G185), STAINLESS STEEL,
SILICON BRONZE OR COPPER. THE COATING WEIGHTS FOR ZINC COATED FASTENERS SHALL BE IN
ACCORDANCE WITH ASTM A 153.
1 ASCE 7-10
CBC 2013
ACI 318-11
SN1
2012 NDS

Das könnte Ihnen auch gefallen