Operation &
Original™ Series PLASTIC Pumps Maintenance
WIL-10220-E-02
REPLACES EOM T4/A4P 5/05
TABLE OF CONTENTS
PAGE #
II Ozone
I&
ss
N
Cla
NO C le
Air
Act 90
an s of 19
t
es
n
U.S. ndme
SEbs
e
Am
nc
ep U
D
ta
leting Su
SECTION 1
T4 PLASTIC
CAUTIONS – READ FIRST!
TEMPERATURE LIMITS: CAUTION: Before any maintenance or repair is
Polypropylene 0°C to 79°C 32°F to 175°F attempted, the compressed air line to the pump should
PVDF –12°C to 107°C 10°F to 225°F be disconnected and all air pressure allowed to bleed
PTFE PFA –28.9°C to 107°C –20°F to 225°F from pump. Disconnect all intake, discharge and air
Neoprene –17.8°C to 93.3°C 0°F to 200°F lines. Drain the pump by turning it upside down and
Buna-N® –12.2°C to 82.2°C 10°F to 180°F allowing any fluid to flow into a suitable container.
EPDM –51.1°C to 137.8°C –60°F to 280°F CAUTION: Blow out air line for 10 to 20 seconds
Viton® –40°C to 176.7°C –40°F to 350°F before attaching to pump to make sure all pipe line
Wil-Flex™ –40°C to 107.2°C –40°F to 225°F debris is clear. Use an in-line air filter. A 5µ (micron) air
Polyurethane 12.2°C to 65.6°C 10°F to 150°F filter is recommended.
Saniflex™ –28.9°C to 104.4°C –20°F to 220°F
PTFE 4.4°C to 104.4°C 40°F to 220°F NOTE: Tighten clamp bands and retainers prior to
installation. Fittings may loosen during transportation.
CAUTION: When choosing pump materials, be sure
to check the temperature limits for all wetted compo- NOTE: When installing PTFE diaphragms, it is impor-
nents. Example: Viton® has a maximum limit of 176.7°C tant to tighten outer pistons simultaneously (turning in
(350°F) but polypropylene has a maximum limit of only opposite directions) to ensure tight fit.
79°C (175°F). NOTE: Before starting disassembly, mark a line from
CAUTION: Maximum temperature limits are based each liquid chamber to its corresponding air chamber.
upon mechanical stress only. Certain chemicals will This line will assist in proper alignment during reas-
significantly reduce maximum safe operating tempera- sembly.
tures. Consult engineering guide for chemical compat- CAUTION: Verify the chemical compatibility of the
ibility and temperature limits. process and cleaning fluid to the pump’s component
CAUTION: Always wear safety glasses when operat- materials in the Chemical Resistance Guide (see E4).
ing pump. If diaphragm rupture occurs, material being CAUTION: When removing the end cap using
pumped may be forced out air exhaust. compressed air, the air valve end cap may come out
WARNING: Prevention of static sparking — If static with considerable force. Hand protection such as a
sparking occurs, fire or explosion could result. Pump, padded glove or rag should be used to capture the
valves, and containers must be properly grounded when end cap.
handling flammable fluids and whenever discharge of NOTE: Non lube-free pumps must be lubricated.
static electricity is a hazard. Wilden suggests an arctic 5 weight oil (ISO grade 15).
CAUTION: Do not exceed 8.6 bar (125 psig) air supply Do not over-lubricate air supply. Over-lubrication will
pressure. reduce pump performance.
CAUTION: “Champ” series pumps are made of virgin CAUTION: Only explosion proof (NEMA 7) solenoid
plastic and are not UV stabilized. Direct sunlight for valves should be used in areas where explosion proof
prolonged periods can cause deterioration of plastics. equipment is required.
SPECIALTY CODES
0100 Wil-Gard II™ 110V 0184 Accu-Flo™, 24V DC coil, PFA coated hardware
0102 Wil-Gard II™ sensor wires ONLY 0185 Accu-Flo™, 24V DC x-proof coil, PFA coated hardware
0103 Wil-Gard II™ 220V 0206 PFA coated hardware, Wil-Gard II™ sensor wires ONLY
0145 Accu-Flo™, 110V AC x-proof coil, Wil-Gard II™ 110V 0360 Accu-Flo™, 24V DC coil, DIN flange
0150 Accu-Flo™, 24V DC coil 0362 Accu-Flo™, 110V AC coil, PFA coated hardware, Wil-Gard II™ 110V
0151 Accu-Flo™, 24V AC / 12V DC coil 0502 PFA coated hardware
0153 Accu-Flo™, 24V AC / 12V DC x-proof coil 0504 DIN flange
0154 Accu-Flo™, 24V DC x-proof coil 0506 DIN flange, PFA coated hardware
0155 Accu-Flo™, 110V coil 0564 Split manifold, inlet ONLY
0156 Accu-Flo™, 110V AC x-proof coil 0567 Split manifold, Accu-Flo™ 24V DC coil
0157 Accu-Flo™, 24 V DC x-proof coil, Intl. PTB approved 0570 Split manifold, Accu-Flo™, 24V AC / 12V DC coil
0159 Accu-Flo™, 24V DC coil, Intl. PTB approved, DIN flange 0603 PFA coated hardware, Wil-Gard II™ 110V
0164 Accu-Flo™, 110V AC coil, Wil-Gard II™ sensor wires ONLY 0604 DIN flange, Wil-Gard II™ 220V
0166 Accu-Flo™, 24V DC coil, Wil-Gard II™ 110V 0606 DIN flange, PFA coated hardware, Wil-Gard II™ 220V
0167 Accu-Flo™, 24V AC / 12V DC coil, Wil-Gard II™ 110V 0608 PFA coated hardware, Wil-Gard II™ 220V
0168 Accu-Flo™, 110V AC coil, Wil-Gard II™ 110V 0612 Ultrapure, PFA coated hardware, male connections
0169 Accu-Flo™, 110V AC coil, PFA coated hardware 0618 Ultrapure, PFA coated hardware, Wil-Gard II™ 110V, male connections
0170 Accu-Flo™, 110V AC x-proof coil, PFA coated hardware 0622 Ultrapure, male connections
0180 Accu-Flo™, 24V AC / 12V DC coil, PFA coated hardware 0624 Ultrapure, Wil-Gard II™ 110V, male connections
0181 Accu-Flo™, 24V AC / 12V DC x-proof coil, PFA coated hardware 0660 Split manifold, Wil-Gard II™ 110V
0183 Accu-Flo™, 24V AC / 12V DC x-proof coil, Wil-Gard II™ 110V 0661 Split manifold PFA coated hardware, Wil-Gard II™ 110V
SECTION 4B
DIMENSIONAL DRAWING
A4 PLASTIC ACCU-FLO™
' DIMENSIONS
MM ITEM METRIC (mm) STANDARD (inch)
&.04
MM %8(!534 A 394 15.5
&.04 B 79 3.1
!)2 ).,%4
C 269 10.6
0 1
D 465 18.3
% E 528 20.8
F 97 3.8
$
G 122 4.8
( H 269 10.6
# J 284 11.2
K 287 11.3
" L 236 9.3
M 180 7.1
! & N 206 8.1
+ * P 13 0.5
,
R 48 RAD. 1.9 RAD.
3 S 64 RAD. 2.5 RAD.
T 15 DIA. 0.6 DIA.
2
. &,!.'%
-
4
SECTION 5B
PERFORMANCE CURVES
T4 PLASTIC ULTRA-FLEX™-FITTED
Height .................................. 528 mm (20.8")
Width ................................... 394 mm (15.5")
Depth .................................. 284 mm (11.2")
Est. Ship Weight........Polypropylene 17 kg (38 lbs)
Air Inlet ....................................10 mm (3/8")
Inlet ..................................... 38 mm (1-1/2")
Outlet .................................. 38 mm (1-1/2")
Suction Lift ......................... 4.88 m Dry (16')
8.23 m Wet (27')
Displacement per
Stroke ........................... 0.68 l (0.18 gal.)1
Max. Flow Rate ................. 235 lpm (62 gpm)
Max. Size Solids ...................4.8 mm (3/16")
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example: To pump 132.5 lpm (35 gpm)
against a discharge pressure head of 2.7 bar
(40 psig) requires 4.1 bar (60 psig) and 51
Nm3/h (30 scfm) air consumption. (See dot
on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air Flow rates indicated on chart were determined by pumping water.
supply pressure.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
SECTION 5D
PERFORMANCE CURVES
T4 PLASTIC PTFE-FITTED
Height.................................. 528 mm (20.8")
Width ................................... 394 mm (15.5")
Depth .................................. 284 mm (11.2")
Est. Ship Weight........Polypropylene 17 kg (38 lbs)
Air Inlet ....................................10 mm (3/8")
Inlet ..................................... 38 mm (1-1/2")
Outlet .................................. 38 mm (1-1/2")
Suction Lift ........................... 2.74 m Dry (9')
8.53 m Wet (28')
Displacement per
Stroke ........................... 0.53 l (0.14 gal.)1
Max. Flow Rate ................. 235 lpm (62 gpm)
Max. Size Solids ...................4.8 mm (3/16")
1
Displacement per stroke was calculated at 4.8 bar
(70 psig) air inlet pressure against a 2 bar (30 psig)
head pressure.
Example: To pump 94.6 lpm (25 gpm)
against a discharge pressure head of 2.7 bar
(40 psig) requires 4.1 bar (60 psig) and 51
Nm3/h (30 scfm) air consumption. (See dot
on chart.)
Caution: Do not exceed 8.6 bar (125 psig) air Flow rates indicated on chart were determined by pumping water.
supply pressure.
For optimum life and performance, pumps should be specified so that daily operation parameters
will fall in the center of the pump performance curve.
SECTION 5F
70/30 OPERATING CONDITION
A4 PLASTIC ACCU-FLO™ TPE-FITTED
This curve demonstrates the flow
created when the stroke rate is modi-
fied under a static air and fluid pres-
sure condition. This curve can be
applied to different pressure conditions
to estimate the change in flow due to
stroke rate.
SECTION 5H
70/30 OPERATING CONDITION
A4 PLASTIC ACCU-FLO™ PTFE-FITTED
This curve demonstrates the flow
created when the stroke rate is modi-
fied under a static air and fluid pres-
sure condition. This curve can be
applied to different pressure conditions
to estimate the change in flow due to
stroke rate.
Suction lift curves are calibrated for pumps operating at and discharge elbows, viscosity of pumping fluid, elevation
305 m (1,000') above sea level. This chart is meant to be (atmospheric pressure) and pipe friction loss all affect the
a guide only. There are many variables which can affect amount of suction lift your pump will attain.
your pump’s operating characteristics. The number of intake
SECTION 6B – ACCU-FLO™
SUCTION LIFT CURVES & DATA
Suction lift curves are calibrated for pumps operating at and discharge elbows, viscosity of pumping fluid, elevation
305 m (1,000') above sea level. This chart is meant to be (atmospheric pressure) and pipe friction loss all affect the
a guide only. There are many variables which can affect amount of suction lift your pump will attain.
your pump’s operating characteristics. The number of intake
WIL-10220-E-02 9 WILDEN PUMP & ENGINEERING, LLC
SECTION 7A
INSTALLATION – T4 PLASTIC
AIR-OPERATED PUMPS
The Model T4 Plastic pump has a 38 mm (1-1/2") inlet and affected if proper attention is not given to elevation (see pump
38 mm (1-1/2") outlet and is designed for flows to 307 lpm performance chart).
(81 gpm). A variety of diaphragms, valve balls, valve seats,
and o-rings are available to satisfy temperature, chemical 4. PIPING: Final determination of the pump site should not be
compatibility, abrasion and flex concerns. made until the piping problems of each possible location have
been evaluated. The impact of current and future installations
The suction pipe size should be at least 38 mm (1-1/2") should be considered ahead of time to make sure that inadver-
diameter or larger if highly viscous material is being pumped. tent restrictions are not created for any remaining sites.
The suction hose must be non-collapsible, reinforced type
The best choice possible will be a site involving the shortest
as the T4 is capable of pulling a high vacuum. Discharge
and the straightest hook-up of suction and discharge piping.
piping should be at least 38 mm (1-1/2"); larger diameter can
Unnecessary elbows, bends, and fittings should be avoided.
be used to reduce friction losses. It is critical that all fittings
Pipe sizes should be selected so as to keep friction losses
and connections are airtight or a reduction or loss of pump
within practical limits. All piping should be supported inde-
suction capability will result.
pendently of the pump. In addition, it should line up without
For T4 Champ models, Wilden offers 150 lb. standard or placing stress on the pump fittings.
metric flanges. The following details should be noted when
Expansion joints can be installed to aid in absorbing the
mating these to pipe works: forces created by the natural reciprocating action of the
• A 60–80 shore gasket that covers the entire flange face pump. If the pump is to be bolted down to a solid foundation,
should be used. a mounting pad placed between the pump and foundation
• The gasket should be between .075" and .175" thickness. will assist in minimizing pump vibration. Flexible connections
• Mating flanges with flat as opposed to raised surfaces between the pump and rigid piping will also assist in minimiz-
should be used for proper mechanical sealing. ing pump vibration. If quick-closing valves are installed at any
• The flanges should be tightened to a minimum of 6.8 N·m point in the discharge system, or if pulsation within a system
(5 ft-lbs) but no more than 13.5 N·m (10 ft-lbs). becomes a problem, a surge suppressor should be installed
A non-raised surfaced-flange adapter should be utilized when to protect the pump, piping and gauges from surges and
mating to the pump’s inlet and discharge manifolds for proper water hammer.
sealing. When pumps are installed in applications involving flooded
INSTALLATION: Months of careful planning, study, and selec- suction or suction head pressures, a gate valve should be
tion efforts can result in unsatisfactory pump performance if installed in the suction line to permit closing of the line for
installation details are left to chance. pump service.
Premature failure and long term dissatisfaction can be avoided The T4 can be used in submersible applications only when both
if reasonable care is exercised throughout the installation wetted and non-wetted portions are compatible with the mate-
process. rial being pumped. If the pump is to be used in a submersible
application, a hose should be attached to the pump’s air exhaust
LOCATION: Noise, safety, and other logistical factors usually and the exhaust air piped above the liquid level.
dictate that “utility” equipment be situated away from the
production floor. Multiple installations with conflicting require- If the pump is to be used in a self-priming application, be
ments can result in congestion of utility areas, leaving few sure that all connections are airtight and that the suction lift is
choices for siting of additional pumps. within the pump’s ability. Note: Materials of construction and
elastomer material have an effect on suction lift parameters.
Within the framework of these and other existing conditions, every Please refer to pump performance data.
pump should be located in such a way that four key factors are
balanced against each other to maximum advantage. Pumps in service with a positive suction head are most effi-
cient when inlet pressure is limited to 0.5–0.7 bar (7–10 psig).
1. ACCESS: First of all, the location should be accessible. If Premature diaphragm failure may occur if positive suction is
it’s easy to reach the pump, maintenance personnel will have 0.8 bar (11 psig) and higher.
an easier time carrying out routine inspections and adjust-
THE MODEL T4 WILL PASS 4.8 mm (3/16") SOLIDS. WHEN-
ments. Should major repairs become necessary, ease of
EVER THE POSSIBILITY EXISTS THAT LARGER SOLID
access can play a key role in speeding the repair process and
OBJECTS MAY BE SUCKED INTO THE PUMP, A STRAINER
reducing total downtime.
SHOULD BE USED ON THE SUCTION LINE.
2. AIR SUPPLY: Every pump location should have an air line
CAUTION: DO NOT EXCEED 8.6 BAR (125 PSIG) AIR
large enough to supply the volume of air necessary to achieve
SUPPLY PRESSURE.
the desired pumping rate (see pump performance chart). Use
air pressure up to a maximum of 8.6 bar (125 psig) depending PUMPS SHOULD BE THOROUGHLY FLUSHED WITH
upon pumping requirements.The use of an air filter before the WATER BEFORE INSTALLING INTO PROCESS LINES.
pump will ensure that the majority of any pipeline contaminants FDA AND USDA PUMPS SHOULD BE CLEANED AND/OR
will be eliminated. For best results, the pumps should use an SANITIZED BEFORE USE ON EDIBLE PRODUCTS.
air filter, regulator, and lubricator system.
BLOW OUT AIR LINE FOR 10 TO 20 SECONDS BEFORE
3. ELEVATION: Selecting a site that is well within the pump’s ATTACHING TO PUMP TO MAKE SURE ALL PIPE LINE
suction lift capability will assure that loss-of-prime troubles will DEBRIS IS CLEAR. ALWAYS USE AN IN-LINE AIR
be eliminated. In addition, pump efficiency can be adversely FILTER.
WILDEN PUMP & ENGINEERING, LLC 10 WIL-10220-E-02
SUGGESTED INSTALLATION
'!5'%
#/-").!4)/. /04)/.!, 3(54 /&&
&),4%2 6!,6%
2%'5,!4/2
,5"2)#!4/2
&,%8)",%
#/..%#4)/.
!)2
3(54
/&&
6!,6% .%%$,% $)3#(!2'%
6!,6%
%15!,):%2§
&,%8)",% 352'% $!-0%.%2
#/..%#4)/.3 0)0% #/..%#4)/. /04)/.!,
349,% /04)/.!,
-5&&,%2
35#4)/. ACCU-FLO™ PUMPS: Accu-Flo™ pumps function with solenoid valves and
require an electrical control circuit to supply pulses. Under normal operating
conditions, the control circuit is sufficient for starting and stopping the pump.
However, the shut-off valve (user supplied) installed in the air supply line
NOTE: In the event of a power failure, the shutoff
can be used to stop the pump if necessary. Therefore, it should be located
valve should be closed, if the restarting of the
far enough away from the pumping equipment such that it can be reached
pump is not desireable once power is regained.
safely in an emergency situation.
SECTION 7D
INSTALLATION – A4 PLASTIC
ACCU-FLO™ PUMPS
Before installing your A4 Accu-Flo™ pump, review Section Pumps in service with a positive suction head are most effi-
7A for general installation suggestions including Location, cient when inlet pressure is limited to 0.5–0.7 bar (7–10 psig).
Access, Air Supply, Elevation, and Piping. Premature diaphragm failure may occur if positive suction
head is 0.8 bar (11 psig) and higher.
The Accu-Flo™ Model A4 has a 38 mm (1-1/2") inlet and 38
mm (1-1/2") outlet and is designed for flow to 235 lpm (62 The solenoid valve is rated for continuous duty; however,
gpm). This maximum flow rate was calculated at 300 strokes stopping on an even number stroke count insures that the
per minute with 100 psig air inlet against 0 psig discharge electrical power is off when pump is stopped. This practice is
head. The A4 Plastic pump is manufactured with wetted safer and also eliminates unwanted strokes when the system
parts of polypropylene or PVDF. The center section of the A4 is shut down and electrical power is off.
Plastic pump is of aluminum or polypropylene construction. THE MODEL A4 WILL PASS 4.8 mm (3/16") SOLIDS. WHEN-
A variety of diaphragms, valve balls, and o-rings are available EVER THE POSSIBILITY EXISTS THAT LARGER SOLID
to satisfy temperature, chemical compatibility, abrasion and OBJECTS MAY BE SUCKED INTO THE PUMP, A STRAINER
flex concerns. SHOULD BE USED ON THE SUCTION LINE.
All wiring used to operate the pump should be placed and
connected according to the proper electrical codes. It is WARNING: Before installation, consult chart in Section
important that the wiring is of adequate gauge to carry 10B to ensure proper electrical connection.
the current required to operate the pump. In addition, it is
necessary that the electrical power supply is large enough
to supply the current required to operate the pump. Wiring WARNING: The solenoid valve should not be used in
should be above ground level if possible (in case of fluid an area where explosion proof equipment is required
spill or leakage), and all wiring and connections which could unless NEMA 7 valve is specified.
become wet or damp should be made watertight.
If the pump is to be used in a self-priming application, be There are three coil options available in both NEMA 4 and
sure that all connections are airtight and that the suction lift is NEMA 7 ratings. One coil allows for 110V AC operation, one
within the pump’s ability. Note: Materials of construction and
allows for 24V DC operation, and the third allows for either
elastomer material have an effect on suction lift parameters.
Please refer to pump performance data. 24V AC or 12V DC operation. See Section 10B for options
and part numbers.
ACCU-FLO™ PLUMBING
CONNECTIONS
SECTION 7E – ACCU-FLO™
SUGGESTED OPERATION AND
MAINTENANCE INSTRUCTIONS
OPERATION: The speed of the pump is controlled electrically. A red button on the side of the air valve is a manual override;
Since each stroke is controlled by an electrical signal, the when actuated it will shift the valve as if an electric current
pump is ideal for batching and other electrically controlled had actuated the solenoid.
dispensing applications.
RECORDS: When service is required, a record should be
Although the speed of the pump is controlled electrically, the made of all necessary repairs and replacements. Over a
air pressure is important. Air pressure displaces the fluid, and period of time, such records can become a valuable tool for
if the pressure is insufficient to complete the physical stroke predicting and preventing future maintenance problems and
before an electronic impulse signals the pump to shift, the unscheduled downtime. In addition, accurate records make
stroke will not be completed, and the displacement per stroke it possible to identify pumps that are poorly suited to their
will be reduced. This does not harm the unit in any way, but applications.
it may cause inaccuracy when attempting to batch specific MAINTENANCE AND INSPECTIONS: Since each applica-
quantities with high precision. tion is unique, maintenance schedules may be different for
every pump. Frequency of use, line pressure, viscosity and
The solenoid operated pump is permanently lubricated during abrasiveness of process fluid all affect the parts life of a
assembly, and requires no additional lubrication under normal Wilden pump. Periodic inspections have been found to offer
operation. If the unit runs under extreme conditions (continu- the best means for preventing unscheduled pump downtime.
ous operation at high speeds), it may be necessary to relu- Personnel familiar with the pump’s construction and service
bricate the center block with a Buna-N compatible NLGI should be informed of any abnormalities that are detected
Grade 2 white EP bearing grease every 50 million cycles. during operation. Internal maintenance is not recommended
Continuous lubrication with a compatible oil is not harmful, for Accu-Flo™ solenoid air valves. When worn or damaged,
and will provide longer seal life, but it may flush all grease out a new air valve body, coil or terminal connector must be
of the unit. purchased. Please consult section 9C for part numbers
WIL-10220-E-02 13 WILDEN PUMP & ENGINEERING, LLC
SECTION 7F – AIR-CONTROLLED
TROUBLESHOOTING
Pump will not run or runs slowly. ing may occur. Replace ball check valves and o-rings
1. Check air inlet screen and air filter for debris. with the proper elastomers.
2. Check for sticking air valve, flush air valve in solvent. 3. Check to make sure all suction connections are air tight,
3. Check for worn out air valve. If piston face in air valve is especially clamp bands around intake balls.
shiny instead of dull, air valve is probably worn beyond Pump air valve freezes.
working tolerances and must be replaced.
4. Check center block Glyd™ rings. If worn excessively, Check for excessive moisture in compressed air. Either
they will not seal and air will simply flow through pump install dryer or hot air generator for compressed air.
and out air exhaust. Use only Wilden Glyd™ rings as they Air bubbles in pump discharge.
are of special construction. 1. Check for ruptured diaphragm.
5. Check for rotating piston in air valve. 2. Check tightness of clamp bands, especially at intake
6. Check type of lubricant being used. A higher viscosity manifold.
oil than suggested may cause the piston to stick or run
erratically. Wilden suggests the use of an oil with arctic Product comes out air exhaust.
characteristics (ISO 15-5 wt.). 1. Check for diaphragm rupture.
Pump runs but little or no product flows. 2. Check tightness of piston plates to shaft.
1. Check for pump cavitation; slow pump speed down to Pump rattles.
match thickness of material being pumped. 1. See E9 Troubleshooting Guide.
2. Check for sticking ball check valves. If material being 2. Create false discharge head or suction lift.
pumped is not compatible with pump elastomers, swell-
SECTION 7G – ACCU-FLO™
TROUBLESHOOTING
Pump will not run. Pump air passages blocked with ice.
1. Check for pressurized air at the inlet. (Min. 3.1 bar [45 Check for excessive moisture in compressed air line. As
psig].) the air expands out the exhaust during the operation of the
2. Check air inlet and filter for debris. pump, water vapor entrapped in the compressed air can
3. Connect a test lamp to the two wires which run to pump freeze and block the air passageways in the pump. If this
and ensure that the lamp cycles on and off. occurs, it may be necessary to install a coalescing filter, an
4. Make sure that the air valve manual override (small red air dryer, or a hot air generator for the compressed air.
knob on front of valve) is switched to the “0” position.
5. Check pilot pressure vent at the top of the operator/coil Air bubbles in pump discharge.
assembly to ensure that it is not clogged. 1. Check for ruptured diaphragm.
6. Check for a worn out air valve. If air continually blows out 2. Check tightness of clamp bands, and the integrity of the
the exhaust in very large quantities, the air valve seals o-rings, especially at intake manifold.
may be worn beyond their ability to function. In this case, Product comes out air exhaust.
the valve must be replaced.
NOTE: Before the valve is scrapped, it is possible that it may 1. Check for diaphragm rupture.
be saved by completely disassembling the valve, cleaning all 2. Check tightness of piston plates to shaft.
components and relubricating the valve. Pump rattles.
Pump runs but little or no fluid comes out. 1. See E9 Troubleshooting Guide.
1. Check that the discharge isolation valve is not closed. 2. Create false discharge head or suction lift.
2. Check that the electronic signal is slow enough that the Solenoid buzzes or solenoid burnout.
pump is able to complete each physical stroke before 1. Incorrect voltage, faulty or dirty solenoid.
it is signaled to change direction. The time required to
complete the stroke is determined by a variety of factors Solenoid valve fails to shift electrically but shifts with
which include fluid viscosity and head pressure. The manual override.
shaft can be viewed if the muffler is removed to verify 1. Incorrect voltage, defective coil or wiring.
that the pump is stroking.
3. Check for pump cavitation; slow pump speed down to Solenoid valve fails to shift electrically or with manual
match the thickness of the material being pumped. override.
4. Check for sticking ball check valves. If the material being 1. Inadequate air supply, contamination, inadequate or
pumped is not compatible with the pump elastomers, improper lubrication, mechanical binding in the valve.
swelling may occur. Replace ball check valves and o-ring
with the proper elastomers. Valve shifts but fails to return.
5. Check to make sure that all suction connections are air 1. Broken spring, mechanical binding.
tight, and that the clamp bands are properly tightened.
Excessive leaking from air valve vent.
1. Worn seals in air valve.
WILDEN PUMP & ENGINEERING, LLC 14 WIL-10220-E-02
SECTION 8A
T4 PLASTIC
DIRECTIONS FOR DISASSEMBLY/REASSEMBLY
CAUTION: Before any maintenance or repair is attempted,
the compressed air line to the pump should be disconnected
and all air pressure allowed to bleed from the pump. Discon-
nect all intake, discharge, and air lines. Drain the pump by
turning it upside down and allowing any fluid to flow into
a suitable container. Be aware of any hazardous effects of
contact with your process fluid.
The Wilden model T4 has a 38 mm (1-1/2") inlet and outlet
and is designed for flows up to 307 lpm (81 gpm). The model
T4 plastic is available in polypropylene wetted parts. The air
valve is manufactured of brass, PTFE-coated brass, nickel-
plated brass or stainless steel. All o-rings used in the pump
are of a special material and shore hardness which should
only be replaced with factory-supplied parts.
TOOLS REQUIRED:
1/2" Wrench
3/16" Allen Wrench
Adjustable Wrench
Vise equipped with soft jaws (such as plywood, plastic DISASSEMBLY: Figure 1
or other suitable material)
Step 1.
NOTE: The model used for these instructions incorporates
Before starting disassembly, mark a line from each liquid
rubber diaphragms, balls, and seats. Models with PTFE
chamber to its corresponding air chamber. This line will
diaphragms, balls and seats are the same except where
assist in proper alignment during reassembly.
noted. The procedures for A4 Accu-Flo™ pumps are the
same except for the air distribution system.
Figure B Figure C
END CAP
Figure D
Grooves In
Bushing Which
Contain Glyd™ Rings
Figure B
AIR VALVE
P/N 04-3800-09-07 AIR INLET PISTON CENTER BLOCK
P/N 08-3210-55-225
Figure E
AIR FILTER
SCREEN
END CAP
T4
PLASTIC 27
AIR-
OPERATED
32
29
28
34
24
33
23
11 26
14
12 25
13
2
22
16
9
3
20
1 35
18
10
Standard
Assembly
19 35 21 39
Outer Ultra-Flex™ Inner 17
Piston Diaphragm Piston Ultra-Flex™ Shaft
Spacer
36
5
37
8
7 Ultra-Flex™
Assembly™
31 30
15 16
T4
PLASTIC
PTFE-
FITTED
./4% 04&% DIAPHRAGM MODELS ASSEMBLED WITH
04&% GASKET KIT AT FACTORY NOT SHOWN
A4
PLASTIC
ACCU-FLO™
NEMA 7 / UL / CSA
Voltage ±10% Current (A)
AC AC
DC Power (W) DC Resistivity
Part Number 60 Hz 50 Hz ±10% Inrush Holding (Ω)
00-2110-99-153 12 24 22 7 .60 .55 .32 19
00-2110-99-154 24 48 44 7 .30 .30 .18 75
00-2110-99-156 60 120 110 7 .12 .13 .06 475