Sie sind auf Seite 1von 3

Triple-Band Combiner

380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz

• Designed for co-siting purposes AUTO-


SENSE
• Enables feeder sharing
• Integrated auto-sense technology for automatic DC / AISG detection and
bypass functionality. Port 4
Combine Mode (near BTS):
DC/AISG auto-sense for port 1…3 and short circuit detection on port
4. The first port (1, 2 or 3) which is supplied with a DC/AISG signal wil
automatically be by-passed to port 4 Port 1

Split Mode (near antenna): Port 2


Automatic DC/AISG by-pass from port 4 to port 1…3 if no short circuit Port 3 Single Unit
is detected
A detailed manual about auto-Sense technology can be downloaded on our
homepage.
• Suitable for indoor or outdoor applications
• Wall or mast mounting
• Available as a single unit, or for XPol antennas as a double unit
• Built-in lightning protection

Double Unit

Technical Data – – – 2690

Type No. 78211457 clam d


ps 78211458
Single Unit c lu de Double Unit
in
Pass band
Band 1 [MHz] 380 – 960
Band 2 [MHz] 1350 – 2200
Band 3 [MHz] 2300 – 2690
Insertion loss
Port 1 ↔ Port 4 [dB] < 0.2 (380 – 960 MHz)
Port 2 ↔ Port 4 [dB] < 0.2 (1350 – 2200 MHz)
Port 3 ↔ Port 4 [dB] < 0.2 (2300 – 2690 MHz)
Subject to alteration.

Isolation [dB] > 50


VSWR < 1.25
Impedance [Ω] 50
Input power
Band 1 / Band 2 / Band 3 [W] < 300 / < 200 / < 200
Intermodulation products [dBc] < −160 (3rd order; with 2 x 20 W)
Temperature range [°C | °F] −40 ... +60 | −40 ... +140
Connectors 4.3-10 female (long neck)
Application Indoor or outdoor (IP 66)
DC/AISG transparency
936.5174/a

Port 1 ↔ Port 4 [mA] Auto-sense (max. 2000)


Port 2 ↔ Port 4 [mA] Auto-sense (max. 2000)
Port 3 ↔ Port 4 [mA] Auto-sense (max. 2000)
Lightning protection [kA] 3, 10/350 µs pulse
Mounting [mm | in] Wall mounting: With 4 screws (max. 8 | 0.315 diameter) /
Mast mounting: With included clamp set
Weight [kg | lb] Single Unit: 3.7 | 8.2 / Double Unit: 7.2 | 15.9
Dimensions (w x h x d) [mm | in] Single Unit: 196.9 x 214.7 x 67.65 | 7.75 x 8.45 x 2.66 /
Double Unit: 196.9 x 214.7 x 138.65 | 7.75 x 8.45 x 5.45
(without connectors, without mounting brackets)

78211457, 78211458 Page 1 of 3

Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
Triple-Band Combiner

380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz

Accessories (included) Typical Attenuation Curves

Type No. Clamp set suitable for Clamp Set Diagram 1


mast diameter of
Port 1↔Port 4 Port 2↔Port 4 Port 3↔Port 4
0
734365 [mm | in] 45 – 125 | 1.77 – 4.92

Attenuation / dB
-10 380 - 960 1350 - 2200 2300 - 2690

-20

-30

-40

Accessories (order separately) -50

Type No. Description 50-Ohm load -60

78210484 50-Ohm load -70

-80

-90

-100
300 500 700 900 1100 1300 1500 1700 1900 2100 2300 2500 2700 2900
Frequency / MHz

Diagram 2
Port 1↔Port 4 Port 2↔Port 4 Port 3↔Port 4
0,00
Attenuation / dB

-0,10 380 - 960

-0,20

-0,30

1350 - 2200 2300 - 2690


-0,40

-0,50

-0,60

-0,70

-0,80

-0,90

-1,00
300 500 700 900 1100 1300 1500 1700 1900 2100 2300 2500 2700 2900
Frequency / MHz

Subject to alteration.
Please Note:
The mounting plates can be removed by loosening the screws j to m (M5 x 12) and
replaced with other means of mounting, always provided that the max. drilled depth of
7.5 mm is respected with the choice of replacement screws.
As a result of more stringent legal regulations and judgements regarding product
liability, we are obliged to point out certain risks that may arise
when products are used under extraordinary operating conditions.

Extraordinary operating conditions, such as heavy icing or exceptional dynamic stress


(e.g. strain caused by oscillating support structures), may result in the breakage of a mast
mounted device or even cause it to fall to the ground.

These facts must be considered during the site planning process.

The Combiners are designed to operate under the environmental conditions as described
in ETS 300 019-1-4 class 4.1 E and have passed environmental tests as recommended in
936.5174/a

ETS 300 019-2-4.

The installation team must be properly qualified and also be familiar with the
relevant national safety regulations.

The details given in our data sheets have to be followed carefully when installing
the combiners and accessories.

The limits for the coupling torque of RF connectors, re-


commended by the connector manufacturers must be
obeyed.

Terminate unused inputs with a suitable 50-Ohm load, e.g.


78210484.

Any previous datasheet issues have now become invalid.

All specifications are subject to change without notice.


Page 2 of 3 78211457, 78211458 The latest specifications are available at www.kathreinusa.com
Kathrein USA Greenway Plaza II, 2400 Lakeside Blvd., Suite 650, Richardson TX 75082
Phone: 214.238.8800 Fax: 214.238.8801 Email: info@kathrein.com
Triple-Band Combiner

380 – 960 MHz 1350 – 2200 MHz 2300 – 2690 MHz

Dimensions
Subject to alteration.
936.5174/a

78211457, 78211458 Page 3 of 3