Beruflich Dokumente
Kultur Dokumente
Home page
Components General Catalog Components 2D/3D CAD Data
CKD CKD
TOP page Download Service TOP page Library
CD/DVD
CD DVD
CKD CAD Data 2D/3D CAD
Digital Catalog Data Library
Intro 1
Guide to the model selection system
Available systems
● Cylinder selection
● Rotary/oscillating cylinder selection
● Shock absorber selection
● C lean air (F.R.L.) component selection
● Dryer selection
● Technical calculations
Selection results are linked with catalog PDFs and CAD data!
2D CAD
Selection results
Catalog PDF
http://www.ckd.co.jp/english/
Intro 2
I N D E X
3, 4, 5-port valve
Guide for CKD Electronic Catalog Intro Page 1
CATALOG EXPRESS
Related products
Catalogs and CAD data
(2D/3D-CAD) can be downloaded
from the CKD website.
http://catalog-search-e.ckd.co.jp/
Intro 3
Search
Selection
Product group Product name Page Caution
Pilot operated 3, 5-port valve 4GA/B
3, 4, 5-port valve 4GA B A B 1
D /4GE /MN4GD/MN4GE M4GA/B
Small pilot operated 3, 4-port valve
MN3E0/MN4E0 763 MN4GA/B
3, 4, 5-port valve
MN3SO/MN4S0
W4GB4
Pilot operated 5-port valve (small pneumatic valve)
4SA0/4SB0 1205 4TB
4F*0EX
Manual selector valve
Manual selector valve HMV/HSV 1705 4F*0E
Ending
Intro 4
User's Guide (How to browse/use the catalog)
1
Search by product name/model No.
If the product name/model No. are already determined, the desired series page can be found.
Search
4GA1 to 3/4GB1 to 3
Pilot operated 3, 5-port valve 4GA/B
3, 4, 5-port valve 3, 4, 5-port valve 4GA B A B 1
Guide for CKD Electronic Catalog Intro Page 1 D /4GE /MN4GD/MN4GE M4GA/B
4GA1 to 3/4GB1 to 3
Small pilot operated 3, 4-port valve
MN3E0/MN4E0 763 MN4GA/B 4GA/B
User’s Guide Intro Page 5 3, 5-port pilot operated valve (plug-in block manifold) 4GA/B (master)
3, 4, 5-port valve
Master valve Intro Page 13 MN3SO/MN4S0
W4GB4
Serial transmission system Intro Page 14 Pilot operated type 5-port valve (small pneumatic valve)
1205 MN4GD/E
Metal base
4SA0/4SB0 4TB
Recommended alternative products
New products
Intro Page 15
Intro Page 16
Pilot operated type 3, 4, 5-port valve (pneumatic valve)
1231
4L2-4/LMF0 MN4GA/B 4GA4/B4
Pilot operated 3, 5-port valve
4KA/4KB
MN3S0/MN4S0
4GD/E
Direct acting 3-port valve
2, 3-port valve 3QRA/3QRB/3QB 1505 4F W4GB4
System selection Intro Page 39
3QR negative pressure switching unit 4F (master)
"Select by cylinder bore size and operating speed" or 2, 3-port valve
MV3QRA/MV3QRB 1525 4TB
"Select by load value and operating time". PV5G/GMF
2, 3-port valve
Systems Ending Page 1 Large flow rate 3-port valve 3MA/B0
1623 4KA/B
4GA4/B4
Ozone proof components Ending Page 5 NP/NAP/NVP
3PA/B
International System of Units (SI units) Ending Page 18 Pilot operated type explosion-proof 5-port valve 4KA/B
Explosion-proof 4F**0EX 1655 P/M/B
JIS symbol list Ending Page 19 (mastr)
Explosion-
● CE Marking Ending Page 30 proof Pilot operated type explosion-proof 5-port valve (pneumatic valve)
1679
NP/NAP/NVP
MN3E 4F
4F**0E CONTENTS
Manual Explosion-proof
● CKD RoHS Compliance Ending Page 32 Manual selector valve
1705
4F*0EX
4F*0E
MN4E 4F
ISO9001/ISO14001 Certification Ending Page 34 Manual selector valve HMV/HSV (mastr)
Series variation 8
W4GA/B2
Index (alphabetic order) Ending Page 38 Manual selector Quick valve HMV/HSV PV5G
2QV/3QV 1713
valve Electrical connections list (wire connections/circuit)
2QV/3QV 11 GMF
Shock absorbing valve PV5
Related products SKH 1723 SKH Product introduction 2
GMF
W4GB4
Related products
3
Serial transmission HSV
2QV
If flow characteristics C have been decided, the desired series page can be found. (2) Notes on wiring
(3) Exhaust check valve
4F
(mastr)
717
751
TotAirSys
(Total Air)
TotAirSys
Series variation 8 PV5G
(4) How to expand reduced wiring manifold 736
(Gamma)
Electrical connections list (wire connections/circuit) 11 Safety precautions GMF 750 Ending
Always read the precautions in the Introduction and on page 750 before use. 7
Product introduction 2 PV5
GMF
Single valve PV5S-0
Horizontal axis:
Body piping (3GA1 to 3/4GA1 to 3) 12
3 Search by flow characteristics C Effective 3QR
cross-sectional area Search method 1 2 3 4 3QB
Search
3
2-port 3-port 4, 5-port Related products
MV3QR
Individual wiring manifold
1 2 4
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
Search method
*2: The port sizes listed are representative examples.
Search
Flow
3MA/B0
Wiring method
Manifold
characteristics 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
C [dm3/(bar)]
Port
Single unit
Reduced
Eff. X-sectional
0 1 5 6 7 10 20 30 40 50 60 80 100 160
wiring
wiring
area (mm2)
3PA/B
Pilot operated 2-port ● P512* -
miniature pneumatic valve Base piping (M3GB1 to 2/M4GB1 to 3) 112
P512* ● B512* M5, Rc1/8
2-port 3-port 4, 5-port Related products
2-port
B512*
● M512* M5 1583
Reduced wiring manifold
M512*
P/M/B
Vertical axis:
B*P512*
N*P512* ● B*P512* M5, Rc1/8
φ4 Push-in
● N*P512*
as S ≈ 5.0 × C. NP/NAP/
fitting
Series/variation namecross-sectional
*1: Effective Body pipingarea S andtosonic
(M3GA1 conductance to
3-T *(D)/M4GA1 C are
3-Tconverted
*(D))
Direct acting 3-port small
pneumatic valve
● 3MA0
φ4 Barbed
fitting (M3)
NVP
*2: The port sizes
3M Series listed are
· Common
●
representative
terminal examples. cable connector/
3MB0
block/D sub-connector/flat
M3
136 1541
To the front page/index
φ4 Barbed
4F*0EX
● M3MA0
fitting (M5)
Serial transmission
0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
M3, M5
●
■
M3MB0 φ4 Push-in fitting
Series variation
φ4, φ6 Barbed fitting
HMVPage
P513* ● B513* M5 × 0.8, Rc1/8
4 5 6 7 10
B513*
M513*
20 ● ·30
Common 40
M513* terminal block/D
M5
50 sub-connector/flat
60 80 cable100
connector/
160158 1583
φ4 Push-in
●
2QV
N*P513*
fitting
●
Direct acting 3-port valve
3QV
3QRA1 M5
3QR Series
● Related products (in-stop valve spacer/air supply spacer/
3QRB1 M5
1505
● M3QRA1 M5, Rc1/8
SKH
●
Related parts 196
M3QRB1 M5, Rc1/8
M5
●
PCD
Direct acting 3-port valve MV3QRA1
φ4, φ6 Push-in fitting
1525
Manifold specifications sheet 204
MV3QR Series
M5
●
1583
MV3QRB1
φ4, φ6 Push-in fitting
M5
Direct acting 3-port ● 3PA1
Technical data
φ4, φ6 Push-in fitting
pneumatic valve
3P Series ● 3PA2
Rc1/8
φ6, φ8 Push-in fitting Silencer
●
(1) Pneumatic system selection guide
3PB1 Rc1/8
744 TotAirSys
● 3PB2 Rc1/8, Rc1/4
Always read the precautions in the Introduction and on page 750 before use. 7
1541
Intro 5
22 Search byseries
product seri
Ending Page 38 to 63 Search by product Intro Pages 7 to 14
If thefrom
Select product’s series
external name is already
appearance determined,
and product description of each s
the desired series page can be found.
Model No. Model Catalog Page C1040 to 8040-W W.M. combination/Standard White Series Aux comp 58 Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ100 ■ Power consumption: 0.6 W
70
AVB**7 Air operated valve for high vacuum Flow valves Ending Page 3 C25N-B Governor for medium pressure gas Flow valves 972
AVP**2 Air operated valve for high vacuum Flow valves Ending Page 3 C3070 to 8070-W F.F.M. combination/Standard White Series Aux comp 76
AZ Tube cutter Aux comp 814 CAC4 Clamp cylinder/double acting/single rod Cylinders II 992
B Booster Cylinder Ending Page 136 CAC-N32/40 Lightweight clamp cylinder/ 4GA/4GB MN4GA/MN4GB 4GD/4GE
B*P51* I Pilot operated 2, 3, 5-port double acting/single rod Cylinders II 1030 Model No. Ports No. Specifications/port size Page Model No. Ports No. Specifications/port size Page Model No. Ports No. Specifications/port size Page
Single valve Manifold/block type (individual wiring/reduced wiring) Single valve
valve/metal base Pneu Val 1604 CAT Cartridge cylinder/single acting, push type Cylinders I 1322 3GA1 to 3 3 Body piping MN3GA 3 Body piping Individual wiring 226 3GD1 to 3 3 Body piping
12 344
4GA1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4 MN4GA 5 φ4 to Rc1/8 Reduced wiring 242 4GD1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4
B110 to 820-W Bracket/for Rotary actuator CAU30 Clean air unit Aux comp 832 3GB1 to 2 3 Base piping MN3GB 3 Base piping Individual wiring 234 3GE1 to 2 3 Base piping
60 384
F.R.L./Standard White Series Aux comp 267 CAV2 Cylinder with valve/double 4GB1 to 3 5 Rc1/8 to Rc3/8 MN4GB 5 φ4 to φ8 Reduced wiring 258 4GE1 to 3 5 Rc1/8 to Rc3/8
Manifold/metal base (individual wiring/reduced wiring) * G screws and NPT screws are also compatible. Manifold/metal base (individual wiring/reduced wiring)
B2019 Regulator Aux comp 344 acting lubrication with valve Cylinders I 694 M3GA1 to 3 3 Body piping Individual wiring 96 M3GD1 to 3 3 Body piping Individual wiring 410
Model No.
M4GA1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4 Reduced wiring 136 M4GD1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4 Reduced wiring 436
B512* S Pilot operated 2-port valve/ CAV2-N Cylinder with valve/double
Catalog name
M3GB1 to 2 3 Base piping Individual wiring 112 M3GE1 to 2 3 Base piping Individual wiring 422
sub-base Pneu Val 1588 acting no-lubrication with valve Cylinders I 694 M4GB1 to 3 5 φ4 to Rc1/4 Reduced wiring 158 M4GE1 to 3 5 φ4 to Rc1/4 Reduced wiring 456
NEW NEW
B513* S Pilot operated 3-port valve/ CCH Coolant check valve Flow valves 860
* G threads and NPT threads are also compatible.
sub-base
(Abbreviation)
Pneu Val 1588 CG Fiber tube push-in fitting
B5142 S Pilot operated 5-port valve/ (clean-room) Aux comp 802 Page P.7 on Page P.22
Page
sub-base Pneu Val 1588 CHB Air operated 2-port ball valve
B6061 Relief valve Aux comp 348 (compact rotary valve)/double acting Flow valves 662
B7019
BBS-A
F.R. unit Aux comp 338
Balancer unit, automatic pressure adjustment Cylinders II 1216
CHBF Air operated 2-port ball valve (compact
rotary valve)/double acting/full bore Flow valves 662
3, 5-port valve equipped with safety function 3, 5-port valve equipped with safety functio
4GA/4GB MN4GA/MN4GB
CHBF-R* Air operated 2-port ball valve (compact
BBS-O Balancer unit, fixed pressure adjustment Cylinders II 1228 Small/medium valve (10/15/18 mm) Large valve (24 mm) Small valve (7.0/10 mm)
rotary valve)/single acting/full bore Flow valves 662
BHA Compact cross roller parallel hand Cylinders II 1506
CHBF-V* Air operated 2-port ball valve (compact rotary Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ160 ■ Power consumption: 1.0 W Cylinders up to φ32 ■ Power consumption: 0.4 W and up
BHA-FC Mechanical hand Cylinders II 1735 valve)/with solenoid valve/double acting/full bore Flow valves 676
CHBF-X*
Model No. Ports No. Specifications/port size Pa
BHA-LN Air operated 2-port ball valve (compact rotary
Model No. Ports No. Specifications/port size Page
Hand with length measuring sensor/
cross roller parallel hand with sensor Cylinders II 1444 valve)/with solenoid valve/single acting/full bore Flow valves 676
C 60
4GA4 5 606 M3 to φ4 772
MN4GD 5 φ4 to Rc1/8 Reduced wiring 532 φ8 to φ12, Rc3/8
MN4GB 5 φ4 to φ8 Reduced
(compact rotary valve)/double acting Flow valves 670 MN4E00 4
Ending 42
M3GB1 to 2 3 Base piping Individual wiring 112
M4GB1 to 3 5 φ4 to Rc1/4 Reduced wiring 158
* G threads and NPT threads are also compatible.
4
Search by specifications and variation
If the variation format is already determined,
Intro Page 29 to 38
Icons (marks)
the desired product can be found.
ForSmall/medium
easier use of the catalog, each
valve (10/15/18 mm)
item is
Large valve (24 mm)
fications and
4 variation Also known as... Search by specifications and variation
marked and
Cylinders up
in the text.
compatible
to φ100 items
■ Power consumption: 0.6 W are indicated
Cylinders up to φ160 ■ Power consumption: 1
NEW
MN4S0 Series MN4S0 One-sided
0.57 to 0.80 - 1170
port valve
(pneumatic valve) MT4S0 solenoid type
M4KA 1272
4K Series
(pneumatic valve)
M4KB 0.60 to 11 - 1284
dimensions.Page P.511 on Page P.59
One-sided
MN4KB 1304
To the
(A)M4F0
0 0.5 to 0.54 - 4F Series M4F1 to M4F3
796 160
1376
solenoid type 3, 5-port valve equipped with safety function Large flow rate 5-port valve
0.6 to 18
(pneumatic valve) M4F4 to 7 (4F7) 1404
corresponding page
M4F**E Explosion-proof 1694
MN4GD/MN4GE
GMF1 1450
4GA4/4GB4
PV5G/PV5/CMF Series
0 - 0.9
2.8 to 11.6 -
(ISO valve) GMF2 1454
2, 3-port valve
1218
0 0.29 to 0.32 - MN3E0 Series MN3E0
M3GA
0.54
0.70 to 2.5
- One-sided 796
96
Pilot operated
soft spool valve
3G Series
96/410
MN3GA 0.71 to 1.7
-
226 Model No. Ports No. Specifications/port size Page Model No. Ports No. Specifications/port size Pa
0.70 to 8.0
MN3S0 Series MN3S0 One-sided
-
(pneumatic valve)
D
(small pneumatic valve)
226/516
M3MB0
- 0.1 to 0.5 1546
4GA4 5
B 0.71 to 2.3 Direct acting poppet
3QR Series
M3QRA
0.30 to 0.40 - 1528 MN4GD 5 φ4 to Rc1/8 Reduced wiring 532 φ8 to φ12, Rc3/8
234/524
valve M3QRB
E 3P Series M3PA
(pneumatic valve) M3PB
0.31 to 1.1 - 1570
MN3GE 3 Base piping Individual wiring 524 Base piping
A2 Pilot operated P/M/B Series
One-sided 874
B*P51
0.09 to 0.15 -
1588
4GB4 5
poppet valve (Miniature pneumatic valve)
Two 3-port valves integrated
N*P512/3/4 1610
MN4GE 5 φ4 to φ8 Reduced wiring 548 Rc3/8, Rc1/2
B2 1.7 to 2.3 - MN3E0 Seriessolenoid/ 878
MN3E0 0.5 - One-sided 796
Manifold/metal base (individual wiring/reduced wiring)
plug-in type
M3G DA 96/410
Z2 Pilot operated
878
M3G BE 112/422
Body piping Individual w
Vertical axis:
3G Series 0.66 to 1.7 -
soft spool valve MN3G DA 226/516
MN3G BE 234/524 M4GA4 5
MN3S0 Series MN3S0 One-sided φ8 to φ12, Rc3/8 Reduced w
B4 6.4 to 7.4 Series
- nametype
Plug-in 1010
0.50 - 1170
(pneumatic valve) MT3S0 solenoid type
3, 5-port valve equipped with safety function 3, 5-port valve equipped with safety function 3, 5-port valve equipped with safety function
Small/medium valve (10/15/18 mm) Large valve (24 mm) Small valve (7.0/10 mm)
Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ160 ■ Power consumption: 1.0 W Cylinders up to φ32 ■ Power consumption: 0.4 W and up
3, 5-port valve equipped with safety function Large flow rate 5-port valve 3, 4-port valve with valve height of 40 mm or less
Intro 7
Search method 1 2 3 4
3, 4, 5-port valve (pilot operated) 3-port valve (direct acting) 2, 3-port valve (pilot operated) Explosion-proof
2, 3-port valve (for air blow) Master valve Manual selector valve Related products Serial transmission system
Medium valve (manifold pitch 16 mm) Large valve (manifold pitch 25 mm) One-sided solenoid/reduced wiring valve
Cylinders up to φ80 ■ Power consumption: 0.6 W Cylinders up to φ125 ■ Power consumption: 1.2 W Cylinders up to φ180 ■ Power consumption: 1.9 W
IP65 compatible plug-in block manifold 3, 5-port valve IP65 equivalent plug-in manifold 5-port valve Plug-in type block manifold 4, 5-port valve
Reduced wiring valve One-sided solenoid/reduced wiring valve Small (valve width 10 mm)
Cylinders up to φ80 ■ Power consumption: 1.8 W Cylinders up to φ40 ■ Power consumption: 0.6 W Cylinders up to φ25 ■ Power consumption: 0.6 W
Intro 8
2 Search by product series
Select from external appearance and product description of each series. NEW indicates models added to the 9th edition.
Intro 9
Search method 1 2 3 4
3, 4, 5-port valve (pilot operated) 3-port valve (direct acting) 2, 3-port valve (pilot operated) Explosion-proof
2, 3-port valve (for air blow) Master valve Manual selector valve Related products Serial transmission system
Poppet type 3-port valve Poppet type 3-port valve Poppet type 3-port valve
Intro 10
2 Search by product series
Select from external appearance and product description of each series. NEW indicates models added to the 9th edition.
Explosion-proof P.1655 to
Pilot operated 5-port valve Pilot operated 5-port valve
Cylinders up to φ250 ■ Power consumption: 4 to 4.5 W Cylinders up to φ250 ■ Power consumption: 4 to 4.5 W
Direct acting poppet type 2, 3-port valve Pilot operated poppet type 2-port valve Poppet type 2-port valve
■ Power consumption: 6.7 to 17 W (60 Hz) ■ Power consumption: 6.7 to 17 W (60 Hz) ■ Power consumption: 7 W (60 Hz)
Pressure and explosion proof enclosure d2G4/d2G2 type Pressure and explosion proof enclosure d2G4/d2G2 type Pressure and explosion proof enclosure d2G4 type for air blow
AB/AG (general purpose valve) AD/AP (general purpose valve) PDVE4 (pulse-jet valve)
Model No. Port size Page Model No. Port size Page Model No. Port size Page
2-port valve AP**E4 Rc 1/2 to 50 flange General Purpose
PDVE4 Rc3/4 to Rc2
AB4*E4 Rc1/4, Rc3/8 AD**E4 Rc 1/2 to 50 flange General Purpose Valves
General Purpose
AB41E2 Rc1/4, Rc3/8 ADK**E4 Rc1/2 to Rc1 Valves
Valves
AB41E4-Z Rc1/4, Rc3/8 AP**E2 Rc 1/2 to 50 flange
3-port valve
AG4*E4 Rc1/4, Rc3/8 General Purpose
AG4*E4-Z Rc1/4, Rc3/8 Valves
Intro 11
Search method 1 2 3 4
3, 4, 5-port valve (pilot operated) 3-port valve (direct acting) 2, 3-port valve (pilot operated) Explosion-proof
2, 3-port valve (for air blow) Master valve Manual selector valve Related products Serial transmission system
Direct acting 2-port valve by target fluid Direct acting 3-port valve by target fluid General purpose direct acting 2, 3-port valve
FA/FG/FV (special purpose valve) FA/FG (special purpose valve) AB/AG (general purpose valve)
Model No. Working fluid/port size Page Model No. Working fluid/port size Page Model No. Port size Page
Single valve Single valve Single valve/2-port valve
FAB For compressed air FAG For compressed air AB Rc1/8 to Rc1/2
General
M5 to Rc1/2 M5 to Rc3/8 Manifold/2-port valve
General Purpose
FGB For dry air FGG For dry air GAB Rc1/4
Purpose Valves General
Rc1/8 to 1/2 Rc1/8 to 3/8 Single valve/large bore size 2-port valve
Valves Purpose
FVB For medium vacuum Manifold AB71 Rc1/2 to Rc1
Valves
Rc1/8 to 1/2 GFAG For compressed air Single valve/3-port valve
General
Manifold M5 to Rc1/4 AG Rc1/8 to Rc3/8
Purpose
GFAB For compressed air GFGG For dry air Manifold/3-port valve
Valves
M5 to Rc3/8 Rc1/8 to 1/4 GAG Rc1/8 to Rc3/8
General
GFGB For dry air
Purpose
M5 to Rc3/8
Valves
GFVB For medium vacuum
M5 to Rc3/8
General purpose pilot operated 2-port valve 2-port valve for air blow Pilot operated 2-port valve for large flow rate air blow
Intro 12
2 Search by product series
Select from external appearance and product description of each series. NEW indicates models added to the 9th edition.
Master valve
3, 5-port valve 3, 5-port valve 5-port valve
Cylinders of φ20 to φ100 Cylinders of φ20 to φ160 Cylinders of φ10 to φ250
Slide valve, manual switching valve Quick valve Shock absorbing valve
Intro 13
Search method 1 2 3 4
3, 4, 5-port valve (pilot operated) 3-port valve (direct acting) 2, 3-port valve (pilot operated) Explosion-proof
2, 3-port valve (for air blow) Master valve Manual selector valve Related products Serial transmission system
Related products
Page P.1745 on
OPP3 Flat cable compatible slave unit UW Serial parallel transmission system
OPP4 Thin shape SAVE NET
OPP5 Degree of protection (IP65) CSN High speed transmission system
Intro Page 31
I/O block compatible
OPP6 Miniature 32 point compatible
NEW OPP7 Thin 32 point compatible
NEW OPP8 Thin 32 point compatible
Intro 14
Recommended alternative products
Production of the series below has been discontinued.
Select recommended alternative products instead.
■ 3, 5-port pilot operated valve (small pneumatic valve) ■ Pilot operated 3, 5-port valve
■ Pilot operated 5-port valve (ISO valve) ■ Pilot operated 5-port valve (ISO valve)
4G Series 4G R Series
Intro 15
New products
The new series below are now available.
Intro 16
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.
Single unit
Series Model No. Port size
Individual
Reduced
Eff. X-sectional
0 1 2 3
wiring
wiring
area (mm2)
B512*
M512* ● M512* M5
B*P512*
N*P512* ● B*P512* M5, Rc1/8
φ4 Push-in
● N*P512*
fitting
φ4 Barbed
Direct acting 3-port small ● 3MA0
fitting (M3)
pneumatic valve
● 3MB0 M3
3M Series
φ4 Barbed
● M3MA0
fitting (M5)
M3, M5
● M3MB0 φ4 Push-in fitting
φ4, φ6 Barbed fitting
φ4 Push-in
● N*P513*
fitting
M5
Direct acting 3-port valve ● MV3QRA1
φ4, φ6 Push-in fitting
MV3QR Series
M5
● MV3QRB1
φ4, φ6 Push-in fitting
M5
Direct acting 3-port ● 3PA1
φ4, φ6 Push-in fitting
pneumatic valve Rc1/8
3P Series ● 3PA2
φ6, φ8 Push-in fitting
● 3PB1 Rc1/8
M5
● M3PA1
φ4, φ6 Push-in fitting
Rc1/8
● M3PA2
φ6, φ8 Push-in fitting
Rc1/8,
● M3PB1
φ4, φ6 Push-in fitting
Rc1/8,
● M3PB2
φ6, φ8 Push-in fitting
Intro 17
Search method 1 2 3 4
Search
2-port 3-port 4, 5-port Related products
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.
0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160
1583
1541
1583
1505
1525
1557
Intro 18
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.
Single unit
Series Model No. Port size
Reduced
Individual
Eff. X-sectional
0 1 2 3
wiring
wiring
area (mm2)
M3
Pilot operated 3-port valve ● MN3E00 φ1.8, φ3, φ4
MN3E Series
M5
● ● MN3E0 φ1.8, φ4, φ6 Push-in fitting
Two 3-port valves M5
● ● integrated MN3E0 φ1.8, φ4, φ6 Push-in fitting
M5
Pilot operated 3-port ● 3KA1
φ4, φ6 Push-in fitting
pneumatic valve M5
4K Series ● M3KA1
φ4, φ6 Push-in fitting
MN3S0 M5
Pilot operated 3-port ● ● MT3S0 φ4, φ6 Push-in fitting
pneumatic valve Two 3-port M5
MN4S0 Series valves integrated
● ● MN3SO φ4, φ6 Push-in
MT3SO fitting
M5
Pilot operated 3-port valve ● 3G A 1
D φ1.8, φ4, φ6 Push-in fitting
4G Series
Rc1/8,1/8NPT,G1/8
● 3G A 2
D φ4, φ6, φ8 Push-in fitting
Rc1/4, 1/4NPT, G1/4
● 3G A 3
3-port
NP13
Large flow rate 3-port valve NP14
NP Series ● NAP11
Rc3/8 to Rc2
NVP11
Intro 19
Search method 1 2 3 4
Search
2-port 3-port 4, 5-port Related products
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.
0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160
763
1231
1165
221
863
1743
660
1623
Intro 20
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.
C [dm3/(bar)]
Single unit
Series Port size
No. Eff. X-sectional
Reduced
Individual
0 1 2 3
wiring
wiring
area (mm2)
Pilot operated 5-port ● W2P513* M5
miniature pneumatic valve
P514* ● P5142 _
B514*
● B5142 M5
W2P513*
B*P514* M5
● B*P5142
Rc1/8
N*P514*
● N*P5142 φ4 Push-in fitting
● 4SB0 M5
M3
● M4SA0
φ4 Barbed fitting
M5
● ● M4SB0 φ4 Push-in fitting
φ4, φ6 Barbed fitting
φ4, φ6 Push-in
MN4S0 Series ● ● MT4S0 fitting
M5
Pilot operated 5-port valve ● 4G A 1
D φ1.8, φ4, φ6 Push-in fitting
4G Series
Rc1/8, 1/8NPT, G1/8
● 4G A 2
D φ4, φ6, φ8 Push-in fitting
Rc1/4, 1/4NPT, G1/4
● 4G A 3
D φ6, φ8, φ10 Push-in fitting
Rc3/8, 3/8NPT, G3/8
● 4G A 4
D φ8, φ10, φ12 Push-in fitting
A M5
● ● M4G D1 φ1.8, φ4, φ6 Push-in fitting
A Rc1/8, 1/8NPT, G1/8
● ● M4G D2 φ4, φ6, φ8 Push-in fitting
A Rc1/4, 1/4NPT, G1/4
● ● M4G D3 φ6, φ8, φ10 Push-in fitting
Rc3/8, 3/8NPT, G3/8
● ● M4GA4 φ8, φ10, φ12 Push-in fitting
Rc1/8, 1/8NPT,
● 4G B 1
E G1/8
Rc1/4, 1/4NPT,
● 4G B 2
E G1/4
Rc1/4, 1/4NPT, G1/4
● 4G B 3
E Rc3/8, 3/8NPT, G3/8
Rc3/8, 3/8NPT, G3/8
● ● 4GB4 Rc1/2, 1/2NPT, G1/2
M5
● ● M4G B
E
1
φ1.8, φ4, φ6 Push-in fitting
Rc1/8, 1/8NPT, G1/8
● ● M4G B
E
2
φ4, φ6, φ8 Push-in fitting
Rc1/4, 1/4NPT, G1/4
● ● M4G B
E
3
φ6, φ8, φ10 Push-in fitting
1/4(RC, NPT, G),
3/8(RC, NPT, G),
● ● M4GB4 1/2(RC, NPT, G)
φ8, φ10, φ12 push-in fitting
Intro 21
Search method 1 2 3 4
Search
2-port 3-port 4, 5-port Related products
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.
0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160
1583
1205
763
1165
Intro 22
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.
Single unit
Port
Reduced
Individual
Eff. X-sectional
0 1 2 3
wiring
wiring
area (mm2)
M5
Pilot operated 5-port valve ● ● MN4G A
D
1
φ4, φ6 Push-in fitting
4G Series
Rc1/8, 1/8NPT, G1/8
● ● MN4G A
D
2
φ4, φ6, φ8 Push-in fitting
φ4, φ6 Push-in
● ● MN4G B
E
1
fitting
φ4, φ6, φ8
● ● MN4G B
E
2
Push-in fitting
● W4GB2 Rc1/4
Pilot operated 5-port valve
W4G2 Series Rc1/8
● ● MW4GA2 φ4, φ6, φ8 Push-in fitting
φ4, φ6, φ8
● ● MW4GB2 Push-in fitting
φ4, φ6, φ8
● ● MW4GZ2 Push-in fitting
Rc1/4, Rc3/8
● ● MW4GB4 φ8, φ10, φ12 push-in *3
M5
● 4KA1
Pilot operated 5-port φ4, φ6 Push-in fitting
pneumatic valve Rc1/8
● 4KA2
φ6, φ8 Push-in fitting
4K Series
4 , 5 -port valve
Rc1/4
● 4KA3
φ8, φ10 Push-in fitting
Rc3/8
● 4KA4
φ10, φ12 Push-in fitting
M5
● M4KA1
φ4, φ6 Push-in fitting
Rc1/8
● M4KA2
φ6, φ8 Push-in fitting
Rc1/4
● M4KA3
φ8, φ10 Push-in fitting
Rc3/8
● M4KA4
φ10, φ12 Push-in fitting
● 4KB1 Rc1/8
M5, Rc1/8
● M4KB1
φ6 Push-in fitting
Rc1/8, Rc1/4
● M4KB2
φ6, φ8 Push-in fitting
Rc1/4, Rc3/8
● M4KB3
φ8, φ10 Push-in fitting
Rc3/8, Rc1/2
● M4KB4
φ10, φ12 Push-in fitting
φ4, φ6, φ8
● MN4KB1
Push-in fitting
φ6, φ8, φ10
● MN4KB2
Push-in fitting
Intro 23
Search method 1 2 3 4
Search
2-port 3-port 4, 5-port Related products
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.
*3: G threads and NPT threads are also compatible.
0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160
221
863
1003
1231
Intro 24
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.
Single unit
Port
Individual
Reduced
Eff. X-sectional
0 1 2 3
wiring
wiring
area (mm2)
● 4F2 Rp1/4
● M4F2 Rp1/4
Rp1/4
● M4F3
Rp3/8
● M4F4 Rc1/4
● M4F5 Rc3/8
● M4F6 Rc1/2
● M4F7 Rc3/4
ISO valve
● PV5G-8, PV5-8 Rc3/8 to Rc3/4
PV5G/
PV5/ ● GMF1 Rc1/4, Rc3/8
GMF
Series ● GMF2 Rc3/8, Rc1/2
Intro 25
Search method 1 2 3 4
Search
2-port 3-port 4, 5-port Related products
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.
0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160
1079
1337
1147
1431
Intro 26
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.
Single unit
Port
Individual
Reduced
Eff. X-sectional
0 1 2 3
wiring
wiring
area (mm2)
● M4F4*0EX Rc1/4
● M4F5*0EX Rc3/8
● M4F6*0EX Rc1/2
● M4F7*0EX Rc3/4
4 , 5 -port valve
● M4F4*0E Rc1/4
● M4F5*0E Rc3/8
● M4F6*0E Rc1/2
● M4F7*0E Rc3/4
●
2
SKH5 3 5 0 Rc3/8 / Rc1/2
Rc1/4 / Rc3/8 /
●
2
SKH3 3 5 8
Rc1/2
Rc1/4 / Rc3/8 /
●
2
SKH4 3 5 8
Rc1/2
Rc1/4 / Rc3/8 /
● SKH318
Rc1/2
Rc1/4 / Rc3/8 /
● SKH418
Rc1/2
Intro 27
Search method 1 2 3 4
Search
2-port 3-port 4, 5-port Related products
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.
0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160
1655
1679
1743
1705
1723
Intro 28
4 Search by specifications and variation
M3G DA 96/410
Pilot operated M3G BE 112/422
3G Series 0.66 to 1.7 -
soft spool valve MN3G DA 226/516
MN3G BE 234/524
MN3S0 Series MN3S0 One-sided
0.50 - 1170
(pneumatic valve) MT3S0 solenoid type
Note: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 x C.
Intro 29
Search method 1 2 3 4
Search
Individual wiring manifolds, reduced wiring manifolds, reduced wiring slave units, reduced wiring blocks, copper and PTFE free,
ozone-proof specifications, rechargeable batteries, clean-room specifications, coolant proof products, manual switching valves
Intro 30
4 Search by specifications and variation
Intro 31
Search method 1 2 3 4
Search
Individual wiring manifolds, reduced wiring manifolds, reduced wiring slave units, reduced wiring blocks, copper and PTFE free,
ozone-proof specifications, rechargeable batteries, clean-room specifications, coolant proof products, manual switching valves
Reduced wiring
slave unit
(serial transmission)
Intro 32
4 Search by specifications and variation
Reduced 固
定 固定
wiring block
確 時リ 確認時リ
認
後 テナ 後1テナ
1
. は .4は
4
N 方向 N・方向
・
m に寄 mでに寄
で
ね せレ ねじせレ
じ
固 ール 固定ール
定
し に爪 してに爪
て
下 掛け 下さ掛け
さ
い い。
。
D sub-connector (T3*) Flat cable connector (T5*) Common terminal block (T1*)
● Quick connections using cables ● Quick connections using cables ● Valve wiring only requires
with connectors with connectors signal wires and a single
● Processing of relay terminal ● Processing of relay terminal block common wire
block and common wiring is and common wiring is not required ● A relay terminal block is not
not required ● An amplification circuit required
embedded is also available
Intro 33
Search method 1 2 3 4
Search
Individual wiring manifolds, reduced wiring manifolds, reduced wiring slave units, reduced wiring blocks, copper and PTFE free,
ozone-proof specifications, rechargeable batteries, clean-room specifications, coolant proof products, manual switching valves
Intro 34
4 Search by specifications and variation
Intro 35
Search method 1 2 3 4
Search
Individual wiring manifolds, reduced wiring manifolds, reduced wiring slave units, reduced wiring blocks, copper and PTFE free,
ozone-proof specifications, rechargeable batteries, clean-room specifications, coolant proof products, manual switching valves
Intro 36
4 Search by specifications and variation
Search
Individual wiring manifolds, reduced wiring manifolds, reduced wiring slave units, reduced wiring blocks, copper and PTFE free,
ozone-proof specifications, rechargeable batteries, clean-room specifications, coolant proof products, manual switching valves
Intro 38
SystemSystem
selectionselection
Even beginners can easily make a model selection.
Workpiece
To Intro Page 40
Workpiece
To Intro Page 51
Intro 39
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time
Selection
Selecting from cylinder bore size and operation speed
Select appropriate fluid control components Refer to Table 2 and select appropriate fluid control
from bore size and theoretical reference components (valve, speed controller, silencer,
speed, and select [required flow rate] piping) and [required flow rate] for corresponding
cylinder bore size and theoretical reference speed.
From to Table 2
* The relationship of the cylinder bore size and speed for the valve (4G Series/4K
Series) is shown in a graph.
"A combination of the valve and the cylinder's standard system" (Example) Intro
Pages 49 to 50
(1) The cylinder average speed is obtained from the combination of the valve and piping system. It is expressed as the cylinder's
piston speed calculated by dividing the stroke length by the time that the piston rod takes from start to end of movement with the
cylinder rod installed facing upward. When the load factor is 50%, the average speed should be approximately the cylinder's
piston speed multiplied by 0.5. (Refer to Intro Page 53 for the relation of load factor and theoretical reference speed. )
(2) The cylinder theoretical reference speed is the value of when one cylinder moves independently.
(3) The valve's effective cross-sectional area used in the calculation for Table 2 is the 2-position value.
(4) This selection guide is for reference. With the CKD sizing program, confirm conditions to be actually used.
Intro 40
System selection
Table 1
Degree of
cylinder speed Low speed Medium speed High speed Ultra high speed
Theoretical reference
speed (mm/s)
250 500 750 1,000
Note) The above table indicates theoretical reference speed at cylinder bore size.
Refer to the individual specifications of each model for the working piston speed range.
Intro 41
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time
Selection
*1: Refer to Intro Page 57 for piping specifications.
4KA120/4KB120 SC3W-6-6
SLM-M5,SLW-6A φ6 x φ4 nylon tube
4GA120R/4GB120R SCL2-06-H66
4KA120/4KB120 SC3W-6-6
SLM-M5,SLW-6A φ6 x φ4 nylon tube
4GA120R/4GB120R SCL2-06-H66
4KA220/4KB220 SC1-6
SLW-6S,SLW-6A φ8 x φ5.7 nylon tube
4GA220R/4GB220R SCL2-08-H88
Intro 42
System selection
Theoretical reference Required composite
Required flow rate
Bore size (mm) speed (mm/s) effective cross-sectional area Valve
(ℓ/min) (ANR)
Note) (mm2) Single solenoid
250 110 1.7
4KA210/4KB210
500 230 3.3
4GA210R/4GB210R
φ40
750 340 5.0
4GA410-10/4GB410-10
250 710 10.3 4F410-10/4F310-10
4KB310-10
Note) The above table indicates theoretical reference speed at cylinder bore size.
Refer to the individual specifications of each model for the working piston speed range.
Intro 43
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time
Selection
*1: Refer to Intro Page 57 for piping specifications.
4GA420-10/4GB420-10
φ15 x φ11.5 nylon tube or
4F420-10/4F320-10 SC1-10 SLW-10A
Rc3/8 steel pipe
4KB320-10
Intro 44
System selection
Theoretical reference Required composite
Required flow rate
Bore size (mm) speed (mm/s) effective cross-sectional area Valve
(ℓ/min) (ANR)
Note) (mm2) Single solenoid
250 1,100 16.1
4GB410-15
4KB410-15/4F510-15
500 2,200 32.2
φ125
750 3,300 48.2
4F610-20
1,000 4,400 64.4
4GB410-15
250 1,400 20.2
4KB410-15/4F510-15
500 2,800 40.4
φ140 4F610-20
750 4,200 60.5
Intro 45
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time
Selection
*1: Refer to Intro Page 57 for piping specifications.
- - - -
4KB420-15
SC-20A SLW-15A Rc1/2 steel pipe
4F520-15
4F720-20 SC-20A SL-20A Rc3/4 steel pipe
- - - -
- - - -
- - - -
- - - -
- - - -
Intro 46
System selection
[Theoretical reference speed]: indicates degree of cylinder speed, expressed as the following formula.
(This value coincides with speed at no load. When load is applied, speed drops considerably.)
VO =1920 × S S
A =2445 × D2 (1)
VO : Theoretical reference speed (mm/s)
A: Cylinder sectional area (cm2)
S: Composite effective cross-sectional area of circuit (exhaust air side) (mm2)
D: Cylinder bore size (cm)
When expressed as a graph, the theoretical reference speed is the speed within the
range where the cylinder moves at a uniform speed
VO = (mm/s)
Stroke ℓ
t3
t1: Time until movement starts
t2: Time of primary delay
t3: Operating time with constant velocity
: Stroke length
* Note/t1 and t2 differ depending on load. At no load, this can be ignored to no ill effect. Time
Intro 47
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time
Selection
■ F.R.L. kit, unit, regulator ■ Air filter ■ Lubricator
Primary pressure 0.7 MPa, set pressure Primary pressure 0.7 MPa, Primary pressure 0.5 MPa,
0.5 MPa, pressure drop 0.1 MPa pressure drop 0.02 MPa pressure drop 0.03 MPa
[Required flow rate]: indicates instantaneous flow rate for operating a cylinder with velocity VO , expressed with the following formula.
Values in the table are when P = 0.5 MPa. The required flow rate is a value necessary to select clean air system components.
Avo (P+0.101) × 60
Q≈ (2)
0.101×104
Q: Required flow rate ( /min) (ANR)
P: Supply pressure (MPa)
[Required effective sectional area]: indicates composite effective cross-sectional area for the exhaust circuit required for
moving the cylinder at speed VO .
(Composite effective cross-sectional area of valve, speed controller, silencer or piping)
[Proper standard system]: indicates the most appropriate combination of valve, speed controller, silencer and bore size for
operating a cylinder with velocity VO . The combination in the table is for a pipe length of 1 m.
Intro 48
System selection
Base piping
Series Solenoid valve Speed Composite effective System No.
Model No. Silencer Piping (1 m) cross-sectional area (mm2)
port size controller Pipe length (1 m)
M4GB110R C4 SC3W-6-4 SLW-6S φ4×φ2.5 1.4 ●
1
4G1
M4GB110R C6 SC1-6 SLW-6S φ6×φ4 2.8 ●
2
750
●
3
●
5 (Note that this differs with working conditions.)
●
2
●
6
●
1
500
250
100
6 20 40 63 80 100(mm)
Intro 49
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time
Selection
MN4G Series (With internal exhaust check valve)
750
Cylinder average speed
●
2 ●
3 ●
4 ●
5
500
●
1
250
0
20 30 40 50 63 (mm)
Cylinder bore size (φ)
4K Series
Solenoid valve Composite effective
Series Speed controller Silencer Piping (1 m) System No.
port size X-sectional area (mm2)
1000
●
1
●
2 ●
3 ●
4
Cylinder average speed
800
600
400
200
Intro 50
System selection
■ How to select
When load (N) and cylinder required operation time (S) are already decided, use [System
selection 2] to select an appropriate model. Follow the following procedures.
From Table 1
Intro 51
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time
Selection
STEP 2 Selecting cylinder bore size
According to the nomogram for cylinder bore size, select the cylinder bore size and read the load
factor at the same time. (Normally, for value F of “Step 1 Confirming conditions”, read the cylinder
bore size whose load factor is close to 50% )
Cylinder bore size D = φ□
(Example) When F = 800N , P = 0.5 MPa , cylinder bore size is φ63 at Load factor 50% .
800
Intro 52
System selection
vo =□
hen Load factor 50%
(Example) W and Stroke length of 200mm cylinder operate with 1.0sec ,
Str
ok
el
en
gth
Str
ok
el
en
gth
Intro 53
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time
Selection
Load factor 50% Load factor 70%
Pipe length 1 m Pipe length 1 m
Operation time t (s)
Str
oke
len
gth
Str
oke
len
gth
Intro 54
System selection
System code □
(Example) In order to operate φ63 cylinder at theoretical reference speed 450 mm/s , C1 system is
ideal.
C system D system
Cylinder theoretical reference speed V0 (mm/s)
450
Intro 55
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time
Selection
STEP 5 Selecting suitable components
According to the standard system table, confirm the model No. of proper system components with the code
found in [STEP 4 Selecting a suitable system].
(Example) CI system
Valve □ Valve: Single 4KB210-08 or 4GB310R-08
Double 4KB220-08 or 4GB320R-08
Speed controller □ Speed controller: SCI-8
Silencer □ Silencer: SLW-8A
Piping □ Piping: φ10 x φ7.2 nylon tube 1 m
4GB210R-08 4GB220R-08
SC1-8 SLW-8A φ10×φ7.2
C1 4KB210-08 4KB220-08 7.8
SCL2-10-H1010 SLW-8S Nylon tube
4F210-08 4F220-08
4GB410-15 4GB420-15
C3 4F510-15 4F520-15 SC1-15 SLW-15A Rc1/2 steel pipe 27
4KB410-15 4KB420-15
4GB410-15 4GB420-15
C4 4F510-15 4F520-15 SC-20A SLW-15A Rc1/2 steel pipe 38
4KB410-15 4KB420-15
Intro 56
System selection Supplemental materials
Effective cross-sectional area for steel pipes and nylon tubes, and recommended max. flow rate for gas pipes
Effective cross-sectional area of steel pipe Effective cross-sectional area of nylon tube
100
80
2000 60
2B
40
1000
Bore size
1 21 B 30
(mm)
1 41 B
20
500
φ10
1B
10 φ9
3 8 φ8
4 B φ7.5
6 φ7
φ6.5
100 2
1
B 4 φ6
φ4
1
4 B
1
Effective cross-sectional area (mm2)
0.8
1 φ3
8 B 0.6
10
0.4 φ2.5
0.3
5 φ2
0.2 φ1.8
0.1
0 0.5 1 2 3 5 10 20 0.5 1 2 3 4 6 8 10 20 30
Intro 57
Flow characteristics display method
Selection
1. Flow characteristics display
The catalog specifications indicate the flow rate as follows.
Components Display Unit Standards
ISO 6358:1989 “Pneumatic fluid power - Components using compressible fluids
New JIS compliant indication C,b
- Determination of flow-rate characteristics” JIS B 8390:2000 (ISO 6358 translation)
Pneumatic JIS B 8373:1993 “Pneumatic 2-port solenoid valves”
JIS B 8374:1993 “Pneumatic 3-port solenoid valves”
components S
Conventional indication JIS B 8375:1993 “Pneumatic 4, 5-port solenoid valves”
JIS B 8379:1995 “Pneumatic noise reduction device”
Cv ANSI(NFPA)T3. 21. 3:1990
2. Explanation
The flow characteristics of the solenoid valves were conventionally indicated with the effective cross-sectional area S. However, JIS
was revised (JIS B 8390:2000), and these are now indicated with the sonic conductance C and critical pressure ratio b.
● Sonic conductance C: Value obtained by dividing the passage weight flow of the
component in the choke flow by the sum of the upstream absolute
2
P2+0.1
-b 293
Q=600×C(P1+0.1) 1- P1+0.1 ………………(2)
273+t
1-b
To calculate effective cross-sectional area S, substitute the value C obtained with C = S/5 above in the above formula.
For subsonic flow, substitute b = 0.5 in formula (2).
Intro 58
Safety Precautions
Be sure to read this section before use.
When designing and manufacturing equipment using CKD products, the manufacturer is obligated
to ensure that the safety of the mechanism, pneumatic control circuit and/or water control circuit
and the system that runs the electrical controls are secured.
It is important to select, use, handle and maintain CKD products appropriately to ensure their safe
usage.
Observe warnings and precautions to ensure device safety.
Check that device safety is ensured, and manufacture a safe device.
WARNING
1 This product is designed and manufactured as a general industrial machine part.
It must be handled by an operator having sufficient knowledge and experience.
3 Observe organization standards and regulations, etc., related to the safety of the device design and control, etc.
ISO4414, JIS B 8370 (General rules for pneumatic systems)
JFPS2008 (Principles for pneumatic cylinder selection and use)
Including the High Pressure Gas Safety Act, Industrial Safety and Health Act, other safety rules, organization
standards and regulations, etc.
●
3 When inspecting or servicing the device, turn OFF the energy source (air supply or water supply), and turn
OFF power to the facility. Discharge any compressed air from the system, and pay enough attention to
possible water leakage and leakage of electricity.
●
4 When starting or restarting a machine or device that incorporates pneumatic components, make sure to
secure system safety, such as pop-out prevention measures.
5 Observe the warnings and cautions on the following pages to prevent accidents.
DANGER: In the case where the product operation is mishandled and/or when the urgency of a
dangerous situation is high, it may lead to fatalities or serious injuries.
WARNING: A dangerous situation may occur if handling is mistaken, leading to fatal or serious
injuries.
CAUTION: A dangerous situation may occur if handling is mistaken, leading to minor injuries or
property damage.
Note that some items indicated with “CAUTION” may lead to serious results depending on the conditions.
All items contain important information and must be observed.
Intro 59
Limited warranty and disclaimer
1 Warranty period
Caution
This warranty is valid for one (1) year after delivery to the customer’s designated site.
2 Scope of warranty
In case any defect clearly attributable to CKD is found during the warranty period, CKD shall, at its own
discretion, repair the defect or replace the relevant product in whole or in part and at no cost, according to its
own judgment.
Note that the following failures are excluded from the warranty scope:
(1) Failures due to use outside the conditions and environments set forth in the catalog or these specifications.
(2) Failures resulting from factors other than this product
(3) Failures caused by improper use of the product.
(4) Failures resulting from modifications or repairs made without CKD consent.
(5) Failures caused by matters that could not be predicted with the technologies in practice when the product
was delivered.
(6) Failures resulting from natural disasters or accidents for which CKD is not liable.
The warranty covers the actual delivered product, as a single unit, and does not cover any damages resulting
from losses induced by malfunctions in the delivered product.
3 Compatibility check
The customer is responsible for confirming the compatibility of CKD products with the customer’s systems,
machines and equipment.
3 Contact
Contact your local CKD Sales Office for information on the Security Trade Control of products and related
technologies in this catalog.
Intro 60
Design/selection
■ Take measures to prevent physical harm or property
1. Checking the specifications
damage in the event of failure of this product.
WARNING CAUTION
■ Use the product in the range of conditions specified
■ Check for leakage current to avoid malfunction caused
for the product.
by leakage current from other fluid control components.
The product in this catalog is designed for use only in a compressed air
system. Use with pressure or temperature exceeding the specifications ● When using a programmable controller, leakage current
may affect the solenoid valve and cause malfunction.
range may result in damage or operation faults. (Refer to specifications)
Note that the values that are affected by leakage current
Contact CKD when using fluids other than compressed air.
depend on the solenoid valve.
Programmable controller
2. Safety design
WARNING
■ Understand the characteristics of compressed air
before designing a pneumatic circuit.
● The same functions as the mechanical, hydraulic, and
electrical methods cannot be anticipated if instantaneous Using 100 VAC 3.0 mA or less (*1)
stopping and holding are required during an emergency stop. Using 200 VAC 1.5 mA or less
● Pop-out, air discharge, or leakage due to air compression Using 12 VDC 1.5 mA or less (*2)
and expansion may occur. Using 24 VDC 1.8 mA or less (*2)
● The supply and exhaust of the valve must operate simultaneously. *1: 1.2 mA or less for the 4G Series.
When the supply is operated in advance, the actuator *2: 1.0 mA or less with the MN4S0 series, 4S0 series, and 3M0 series.
switching will be delayed.
When the exhaust is operated in advance, the actuator speed ■ Observe the following precautions when using
will be uncontrollable, causing the popping out phenomenon.
nylon tubes or urethane tubes for piping material.
● Use flame-resistant tubes or metal steel pipes in an
■ Make sure that the switching signals of the
environment where spattering may occur.
2-position and 3-position double solenoids are ● Use hydraulic hose when piping is for both hydraulic and
never energized at the same time. pneumatic use.
● When using the standard push-in fitting on the spiral tube,
■ When using a 3-position all ports closed valve with fix the base of the tube with a hose clamp.
a custom stroke, the properties of compressed air Rotation may occur, causing a reduction in holding force.
make it impossible to brake at an accurate position. ● Use a fastening fitting in a high-temperature atmosphere.
The push-in fitting cannot be used.
In addition, as valves and cylinders, etc., are designed
to allow small volumes of air leakage, pressure retention
applications are not available, as they may cause the 3. Working environment
stop position to change or cause a pressure drop.
WARNING
■ Pay attention to the electric circuit during emergency ■ Confirm before use that the product will withstand
stop and to the cylinder operation during power outages. the working environment.
● If the 2-position double solenoid is started and then switched, it will hold
● This product cannot be used in an atmosphere containing
that status unless a reverse operation electrical signal is input.
corrosive gas, chemical liquids, solvents, water or steam. If
water, oil, or metal chips (spatter or cutting chips, etc.) could
■ Install
a “pressure switch” and “shut-off valve” on come in contact with the product, provide appropriate protection.
the device’s compressed air supply side. ● Consult with CKD if ozone is generated in the supplied
● The pressure switch will disable operation until the set pressure air. (Ozone-proof products are available.)
is reached. The shut-off valve releases compressed air into the ● Products other than explosion-proof solenoid valves cannot
pneumatic pressure circuit to prevent accidents caused by be used in an atmosphere containing explosive gas.
operation of pneumatic components under residual pressure.
■ Install the product where it will not be exposed to
Valve
Cylinder
rain, water, direct sunlight, or high temperatures.
Compressor
Shut-off valve Pressure switch
(The explosion-proof 4F ** OE series and outdoor 4F-W
series are available for outdoor use.)
Caution
moisture inside the piping.
■ Use clean air.
● If compressed air contains chemicals, synthetic oils
containing organic solvents, salt, or corrosive gas, do not
use as it can cause damage and/or operation failure.
4. Durability
Air filter
WARNING (5 μm or less)
Dryer
■ Decide on a method of lubricating pneumatic
components, and provide correct maintenance. ● Moisture will occur if the temperature drops in the
● Is it a no-lubrication? pneumatic piping or pneumatic components.
● Is it a lubrication? ● Operation faults could occur if moisture enters the air flow path
of pneumatic components and temporarily blocks passage.
Specify either of the above for control of lubricant.
● Moisture could cause rust, making the pneumatic
components fail.
■ Ultra dry air is not suitable for pneumatic components. ● The drain will flush the lubricant oil and cause a
● Ultra dry compressed air will shorten the life of pneumatic lubrication defect.
components. For use, be sure to use a solenoid valve for
DC voltage drive.
■ Usecompressed air that does not contain oil
■ Continuous energizing during use may accelerate oxides, tar, carbon, etc., from the air compressor.
degradation of the solenoid valve. Contact CKD ● If oil oxides, tar, or carbon enter the pneumatic
components and solidify, resistance at the sliding section
when using the solenoid valve under such conditions. will increase, leading to operation failure.
● When using a product with continuous energization, be ● If the supplied lubricant mixes with oil oxides, tar, carbon,
sure to use items with DC voltage specifications or fluoro etc., the sliding section of the pneumatic component
rubber specifications. could be worn down.
5. Pneumatic source ■ Use compressed air that does not contain solid
foreign matter.
CAUTION ● Any solid foreign matter in the compressed air can enter
■ Install
the pneumatic components and cause wear or locking in
a pneumatic filter just before the pneumatic
the sliding parts.
component in the circuit.
Air filter
(5 μm or less)
Intro 62
6. Usage method 8. Clearly indicated in the instruction manual
WARNING CAUTION
■ Do not narrow the exhaust port of the manifold valves. ■ Indicate the maintenance conditions in the device’s
● There may be cases where other cylinders are subject to instruction manual.
unintended operation due to back pressure generated from ● The product's performance may drop too low to maintain
the exhaust of the switching valve. In this case, individually an appropriate safety level depending on usage
install a manifold two-sided exhaust type or a single exhaust conditions, working environment and maintenance status.
spacer equipped type with the valve causing the situation. With correct maintenance, the product functions can be
used to the fullest.
CAUTION
■ Make sure that the instantaneous energizing/
manual override of the double solenoid 2 position
valve is 0.1 seconds or more.
However, as the cylinder may malfunction due to
secondary side load conditions, it is recommended
that energizing/manual override is performed until
the cylinder reaches the stroke end position.
● With the internal pilot, the supply pressure may drop lower
than the specified range and cause malfunctioning. In this
case, use the external pilot.
■C
ontinuous energizing for long periods may
accelerate degradation of the solenoid valve. Consult
with CKD when energizing this device continuously.
Furthermore, use caution under the following
working conditions, as with continuous energization:
-W hen performing continuous energizing for a long
period of time or when the energized time in a single
day will be longer than the non-energized time
Install with an eye to heat dissipation.
■W
ith the internal pilot solenoid valve, turn the power
on after applying the supply pressure.
The main valve may stop at an unintended position
and prevent proper switching.
7. Securing of space
CAUTION
■ Secure sufficient space around the solenoid valve
for installation, removal, wiring, and piping work.
Intro 63
Mounting, installation and adjustment
Caution
1. Installation 2. Pre-operation confirmation
WARNING CAUTION
■ When mounting a valve, do not use a mounting ■ When supplying compressed air after connecting
method that relies on support from the piping. pipes, do not suddenly apply high pressure.
● Mount and fix the valve body. ● The pipe connection could dislocate, causing the pipe
tube to fly out, leading to accidents.
■ After mounting, do not clean or paint with water or solvent. ● Caution: If compressed air is supplied too slowly, sealing pressure
● Otherwise some resin parts may be damaged. may not be generated depending on the internal sealing
● Paint could plug the pilot exhaust port and result in malfunctions. mechanism of the solenoid valve and may cause air leakage.
■ Do not narrow the exhaust port to a smaller one ■ As air leakage may occur when compressed air is
than the bore size of the piping connection port. supplied with the two 3-port valves integrated
(The pilot exhaust port is also included as an (differential pressure return) without piping to the
exhaust port) output port, be sure to supply the compressed air
● Either attach a silencer or install a solenoid valve so that after piping the output port.
the exhaust port is facing downwards.
An inhale effect may be generated at the exhaust port ■ Before supplying compressed air after connecting pipes,
due to valving element operations and cause the intake of check that there are no air leaks at any pipe connections.
foreign matter near the exhaust port. ● Apply a leakage detection agent to pipe connections with
If the exhaust port is facing upwards, foreign matter may a brush and check for air leaks.
fall into it.
● The actuator will not operate correctly if the exhaust air is not
discharged smoothly. With the manifold, the exhaust air may 3. Adjustment
prevent the correct operation of other solenoid valves.
WARNING
■ Do not block the pilot exhaust port (PR port).
■ When the manual operation device of the solenoid
● Pilot pressure will not be discharged and will fail to operate.
valve has been operated, always be sure to operate
■ Remove the valve packaging and dust-proof seal of the device after reset to the origin (default position).
the piping port just before starting piping. Be sure to check that the non-locking has
● Removing the dust-proof seal of the piping port before the automatically returned or that the locking is in a
piping work starts could allow foreign matter to enter the state where the lock is released (OFF state).
valve from the piping port and cause failure or misoperation.
[Example] OFF OFF
■ Check that tubing is not worn or damaged.
● Tubing could collapse, rupture, or become dislocated. ON ON
Intro 64
■ Connect piping so that connections are not
4. Piping
dislocated by equipment movement, vibration, or
CAUTION tension.
● Control of actuator speed will be disabled if piping on the
■ When connecting pipes, wrap sealing tape in the exhaust side of the pneumatic circuit is disengaged.
opposite direction from the threading, from the ● When using the chuck holding mechanism, the chuck
inside position to within 2 mm from the pipe end. may be released, creating a hazardous state.
● Cut the push-in fitting tube at right angles with a dedicated
● If sealing tape protrudes from the pipe threads, it could be
tool.
cut when screwing the bolts in. This could cause the tape
● Confirm that the tube has been inserted properly, and
to enter the solenoid valve, causing failures.
make sure that there is no tension during use. The tube
could be dislocated or damaged if there is any tension.
Solid Solid
liquid liquid
sealant sealant ■ Make
sure that there is no torsion, tension or
moment load applied to the fitting or the tube.
■ Alwaysflush just before piping pneumatic ■ Securely insert the tube to the tube end, and make
components. sure that the tube cannot be pulled off.
● Any foreign matter that has entered during piping must be
removed so it does not enter the pneumatic components.
■ Cut the tube with a dedicated cutter and always at
a right angle.
Removing
foreign matter
M3 0.3 to 0.6
M5 1.0 to 1.5
Rc 1/8 3 to 5
Rc 1/4 6 to 8
Rc 3/8 13 to 15
Rc 1/2 16 to 18
Rc 3/4 19 to 40
Rc 1 41 to 70
Intro 65
Use/maintenance
Caution
1. Maintenance and inspection 2. Removal
WARNING WARNING
■ When the manual operation device of the valve has ■ Beforeconducting maintenance, turn the power
been operated, always be sure to operate the OFF, stop the supply of compressed air and make
device after reset to the origin (default position). sure that there is no residual pressure.
Be sure to check that the non-locking has ● Observe the conditions to ensure safety.
automatically returned or that the locking is in a
state where the lock is released (OFF state).
[Example]
OFF OFF Power supply
OFF
ON ON
Note: A
s this varies depending on the model, refer to the 3. Disassembly/assembly
pages of each model for operation methods.
WARNING
● The solenoid valve will operate as soon as the power is
turned ON, which is hazardous. ■ Read the relevant product’s instruction manual
● When the manual override device is used for operation at thoroughly and fully familiarize yourself with the
the operating position, abnormal operation is a risk.
task before disassembling or assembling the
■ Conduct daily inspections and regular inspections to solenoid valve.
ensure that maintenance control is done correctly. ● Personnel must be fully familiar with solenoid valve structure
and operational principles and safety requirements.
● If maintenance is not correctly managed, the product's
● Pneumatic Pressure Skill Test Class 2 or higher level is
functions could deteriorate markedly and lead to a
required.
shortened service life, faults and accidents.
6. Lubricator control
● Is the oil volume adjustment normal?
7. Lubricant control
● Is the lubricant that is being supplied an official item?
Intro 66
Reduced wiring valve / product-specific cautions (MN4E, M(N)4G AB , MW4G2, MW4G4, MN4S0, M(N)4TB Series)
CAUTION
Install the wiring while sufficiently checking the polarity, voltage, and terminal numbers.
● Voltage drop may occur due to simultaneous energizing or cable length.
Confirm that the voltage drop for the solenoid is within 10% of the rated voltage.
(1) Serial transmission (with T6*, T7*, and T8*) (2) Connector (T50, T50A)
● These models are dedicated for use with a working ● As it is necessary to match the signal arrangement of the
voltage of 24 VDC. PLC output unit with the signal arrangement on the valve
side, direct connections with a PLC are currently limited.
● If operation may be affected by noise, wire the power supply Establish connections with wiring connection examples
independently for each manifold solenoid valve when possible. (MN4E series: page 834, M4G AB /MN4G AB series: page 722,
MN4S0 series: page 1194, M4TB/MN4TB series: page
● Keep the power supply cable as short as possible. 1128) as a reference. For the cables, use dedicated
cables for each PLC manufacturer.
● Do not share power with an inverter or components
causing motor noise, etc. ● These models are dedicated for use with a working
voltage of 12 and 24 VDC.
● Do not lay the power wire, signal wire, and other power
● When connecting the T50, T50A type to a general output
cables in parallel.
unit, use the + terminal (20, 10) of the 20P connector as
the + side common, and use the NPN transistor output
● The slave units are dedicated for each manufacturer.
open collector type for the drive circuit.
There is no compatibility.
Contact CKD when using the PNP transistor output.
● For how to wire the slave unit, follow the instructions provided ● When wiring of the T50, T50A has been installed
from the PLC manufacturer. The terminal numbers of the slave according to the wiring connection examples (M4TB,
unit are displayed on the attachment side of the slave unit. MN4TB series: page 1128), supply the power supply from
the terminal included as an accessory.
● For information regarding the PLC, please contact the In this case, be sure not to make a mistake with the
corresponding PLC manufacturer. polarity. Making a mistake will cause a short circuit.
Contact CKD for inquiries regarding the UNIWIRE system (embedded fuse will blow)
and SAVE NET.
● Do not connect this solenoid valve to the input unit as
● When installing a manifold solenoid valve vertically, install major faults could occur in this device and in peripherals.
the slave unit at the top end. Connect this solenoid valve to the output unit.
Although common connectors are employed with the input
● With the T8* series, be sure to use waterproof caps and units and output units of the relay terminal series by
waterproof plugs on connectors of the I/O slave units that OMRON and Panasonic Electric Works Co., Ltd., the pin
will not be used. arrangement and polarity of the power supply are different.
The pin arrangement of the T50 type of this solenoid valve
aa
bb
A
PU
SH
O
N
B
PU
A
SH
O
N
B
C 020
N
KD
4S
C 02
N
KD 0
4S
CAUTION
■ Install
so that no force is applied to the connector
section. The fixing screws may loosen if force is
applied to the connector section.
● The connector rotates upwards and sideways.
T6* T7* Further fasten the fixing screws after installation of the
(4G Series)
solenoid valve can fix the connectors.
● Make sure that the tightening torque of the fixing screws
is 0.3 to 0.36 N·m.
12
/14
a
b
a
1P
b
A
PU
SH
O
N
B
A
PU
SH
O
N
B
C 020
N
5R
KD
4S
2B /
C 020
N
KD
2B
4S
2B
2B
4A
T7* T8*
(MN4E Series) Fixing screw
(W4G2 Series)
Intro 67
Reduced wiring valve / product-specific cautions (MN4E, M(N)4G AB , MW4G2, MW4G4, MN4S0, M(N)4TB Series)
Caution
CAUTION (4) Terminal block (T10, 11)
(3) Connector (T30, T31, T51, T52, T53, TM*) ● Install the terminal block in a location that is out of reach
or place a cover on the unit.
● These models are dedicated for use with a working
voltage of 12 and 24 VDC.
a
b
a
b
A
PU
SH
O
N
B
● Use the 4S0 Series with the + common.
A
PU
SH
O
N
B
C 020
N
KD
4S
C 020
N
KD
4S
CAUTION
■ Install
so that no force is applied to the connector
section. The fixing screws may loosen if force is
applied to the connector section.
● The connector rotates upwards and sideways.
Further fasten the fixing screws after installation of the
solenoid valve can fix the connectors.
● Make sure that the tightening torque of the fixing screws T10 terminal T11 terminal
is 0.3 to 0.36 N·m. appearance appearance
a
b
a
b
A
PU
SH
O
N
B
A
PU
SH
O
N
B
C 020
N
KD
4S
C 020
N
KD
4S
Fixing screw
● Plug the connectors in all the way to ensure that the lock
is engaged.
1P
2B 3/5R
2B
2B
2B
4A
4A
4A
4A
4A
Intro 68
Electrical connection list (Single valve/individual wiring manifold)
* Refer to Intro Pages 30 to 33 for reduced wiring manifolds.
● Selection of electrical connections, manual operating devices, and options : Yes
Description Voltage (V) Electrical
Series
Page (Power consumption W) connections
3QR Series 1505 1 2 3 4 5 Grommet lead wire
6 7 8 9 10 1 Circuit diagram a
Standard *1 11 12 13 14 15
12 VDC (2.0 W)
24 VDC (1.8 W) 16 17 18 19 20
21 22 23 24 25
*1: Some models differ depending on the
specifications. 26 27 28 29 30
3M Series 1541
Standard
1 2 3 4 5
6 7 8 9 10
24 VDC (0.6 W)
Option 11 12 13 14 15
12 VDC (0.6 W) 16 17 18 19 20 Compact terminal box
6 VDC (0.9 W)
5 VDC (0.9 W) 21 22 23 24 25 6 None S
Circuit diagram b
26 27 28 29 30
6 VDC (0.9 W)
5 VDC (0.9 W) 21 22 23 24 25
26 27 28 29 30
Intro 69
Refer to the next page for circuit diagrams a to h .
Caution
Electrical connections None : Without lead wire I : With lead wire L : With indicator lamp
(wiring method) S : With surge suppressor N : Without socket
Grommet lead wire Conduit lead wire Compact terminal box (G1/4) Compact terminal box
2 S 3 4 None 5 None L
Circuit diagram b Circuit diagram a Circuit diagram a Circuit diagram c
DIN terminal box Round terminal box Round terminal box Round terminal box
12 None L 13 (G1/2 / G3/4) 14 L 15 + Ground (A-15a) equipped
Circuit diagram c Circuit diagram e Circuit diagram f Circuit diagram e
Refer to the
next page
for circuit
C type connector C type connector C type connector C type connector diagrams
17 I 18 None 19 I S L 20 None S L of the electrical
Circuit diagram a Circuit diagram a Circuit diagram g Circuit diagram g connections.
*2: The voltage of the 4T series is similar to 4K and the electrical connections are NO.30.
Intro 70
Electrical connection list (single valve/individual wiring manifold)
● Selection of electrical connections, manual operating devices, and options : Yes
Voltage (V)
Series Page (Power Electrical
consumption W)
connections
Grommet lead wire
31 I
4G1 to 3 Series 7
31 32 33 34 35 36 Circuit diagram a
100 VAC
24 VDC (0.6 W) 37 38 39 40 41 42
MN4G Series 221 12 VDC (0.6 W)
3, 5-port valve
43 44 45
100 VAC
100 VAC 31 32 33 34 35 36
Circuit diagram
With surge suppressor and
a Basic c With indicator lamp f Round terminal box/with lamp g indicator lamp, cont.
* With the 4G1 to 3 Series
( to ) AC
( to )
AC A B C
AC
( to )
( to )
Y
(±) SOL (±)
DC
DC
(±) A B C DC
(±)
-
The DC model has a surge suppressor Y * A type connector for DC only
+
SOL
* For W4G2 Series
* With the 4G1 to 3 Series (Single)
( )
d Compact terminal box/with lamp g With surge suppressor and indicator lamp
AC
( to ) COM
SOLa
( to ) A
AC ( to )
( ) AC AC (±) COM
( to ) DC SOLa
Red
(±) A
DC (±)
DC (Double)
(±)
( to ) B
* Grommet lead wire for DC only Black
SOLb
A B C (±)
B
(-) Black SOLb
Y DC (±) COM
* Note that models with surge suppressor
SOL and lamp have polarity. SOLa
* Diode is used as a surge suppressor. A
(±)
Intro 71
For circuit diagrams of ○
a ,○
g , and ○
h , refer to the circuit diagrams of the following table.
Caution
Electrical connections (wiring method)
None :
Without lead wire I : With lead wire L : With indicator lamp
S : With surge suppressor N : Without socket
E type connector E type connector E type connector E type connector E type connector
32 I 33 N 34 With socket/terminal 35 I S L 36 N L S
Circuit diagram a Circuit diagram a Circuit diagram g Circuit diagram g
For AC voltages, the
● Lead wire length a dimension is 3.5 mm
300 mm longer than for DC
500 mm
1m voltages.
2m
3m
A type connector (downward) DIN terminal box EJ type connector with cover EJ type connector with cover Terminal block I/O connector
38 N 39 S L 40 I 41 I S L 42 L S 43 I S L
Circuit diagram g Circuit diagram h Circuit diagram a Circuit diagram h Circuit diagram g Circuit diagram g
2:B 1:COM
Unused 4:A
● ● ●
B COM A
I/O connector Individual wiring D-connector D* Individual wiring D-connector socket Individual wiring connector
45 I S L 46 I S L 47 None, with socket/terminal D* 48 with lead wire C I S L
Circuit diagram g I S L Circuit diagram g Circuit diagram g
* MN3E0/MN4E0 only * MN3E0/MN4E0 only ● Lead wire length
C : 300 mm
C0: 500 mm
C1:1000 mm
C2:2000 mm
2:B 1:COM(NPN)
3:COM(PNP) 4:A
DIN terminal box with Optional surge suppressor DIN terminal box with surge
h surge suppressor/lamp i attached (AC/DC) j suppressor/lamp
* With the MN4E Series * With the 4G Series Surge suppressor
(Single)
( to ) (Single)
( to ) AC included
a ( to ) Use a surge suppressor
(+, -)
AC when controlling the unit
R
Varistor
LED a Red with semiconductors. AC
sol ( to )
COM (+)
(-, +) DC Use a lead wire that is
(±) (-) 20/0.18.
(Double) Black With the DC model, only
DC Diode
the grommet lead wire is No.1 No.3 No.2
a SOL COM b SOL
a
(+, -)
(±) Diode has polarity. the suppression type in
LED
R the figure below.
a
5
23.
COM sol
(-, +) DC
16
b
b LED sol
(+, -) R
8
(Single)
a
(+, -)
Intro 72
Intro 73