Sie sind auf Seite 1von 73

Guide to CKD CAD data

How to use CKD’s CAD data


CKD’s CAD data is provided for your use in CAD design.

2D CAD data 3D CAD data


Types of Types of
compatible CAD compatible CAD
· DXF
· DXF
· IGES
· ‌Dedicated CAD
· SAT
types
· Parasolid
· ‌Dedicated CAD
types

Home page
Components General Catalog Components 2D/3D CAD Data
CKD CKD
TOP page Download Service TOP page Library

CD/DVD

CD DVD
CKD CAD Data 2D/3D CAD
Digital Catalog Data Library

How to obtain CAD data


■ To use the CD-ROM or DVD versions, consult with your nearest CKD branch or dealer.
■ To use the website, access the following address:
URL: http://www.ckd.co.jp/english/
If the CAD data you need is not listed, consult with your nearest CKD branch or dealer.

Intro 1
Guide to the model selection system

How to use the model selection system


The CKD system supports selection of the following items.
For your use during model selection and design.

Available systems

● Cylinder selection
● ‌Rotary/oscillating cylinder selection
● Shock absorber selection
● C ‌ lean air (F.R.L.) component selection
● Dryer selection
● Technical calculations

Selection results are linked with catalog PDFs and CAD data!

2D CAD
Selection results
Catalog PDF

Registration is not required-available at any time!

A variety of services such as


CKD product catalogs, PDF, CAD
data and model selection are
available. Feel free to try them.

http://www.ckd.co.jp/english/

Intro 2
I N D E X
3, 4, 5-port valve
Guide for CKD Electronic Catalog Intro Page 1

User’s Guide Intro Page 5

1 Search by product name/model No.


Product name Intro Page 3
Model No. index in alphabetic order Ending Page 38

2 Search by product series Intro Page 7


Select from external appearance and product description of each series.

Master valve Intro Page 13


Serial transmission system Intro Page 14
Recommended alternative products Intro Page 15
New products Intro Page 16

3 Search by flow characteristics C Intro Page 17

4 Search by specifications and variation Intro Page 29

System selection Intro Page 39


"Select by cylinder bore size and operating speed" or 2, 3-port valve
"Select by load value and operating time".

Safety precautions Intro Page 59


* ‌For cautions for individual products, read the cautions for the
corresponding series.

Flow characteristics display method Intro Page 58


Systems Ending Page 1
Ozone proof components Ending Page 5
International System of Units (SI units) Ending Page 18
JIS symbol list Ending Page 19 Explosion-
● CE Marking Ending Page 30 proof

● CKD RoHS Compliance Ending Page 32


ISO9001/ISO14001 Certification Ending Page 34
Index (alphabetic order) Ending Page 38 Manual selector
valve

CATALOG EXPRESS
Related products
Catalogs and CAD data
(2D/3D-CAD) can be downloaded
from the CKD website.
http://catalog-search-e.ckd.co.jp/

Intro 3
Search
Selection
Product group Product name Page Caution
Pilot operated 3, 5-port valve 4GA/B
3, 4, 5-port valve 4GA B A B 1
D /4GE /MN4GD/MN4GE M4GA/B
Small pilot operated 3, 4-port valve
MN3E0/MN4E0 763 MN4GA/B

3, 5-port pilot operated valve (plug-in block manifold) 4GA/B (master)


W4GB2/MW4GA2/MW4GB2/MW4GZ2 863
4GD/E
Pilot operated 5-port valve (plug-in manifold)
W4GB4/W4GZ4/MW4GB4/MW4GZ4 1003 M4GD/E

Pilot operated 4, 5-port valve MN4GD/E


4TB 1079
4GA4/B4
Pilot operated 5-port valve (pneumatic valve)
4L2-4/LMFO 1147 MN3E/MN4E

Pilot operated 3, 4-port valve (pneumatic valve) W4GA/B2


1165

3, 4, 5-port valve
MN3SO/MN4S0
W4GB4
Pilot operated 5-port valve (small pneumatic valve)
4SA0/4SB0 1205 4TB

Pilot operated 3, 4, 5-port valve (pneumatic valve) 4L2-4/LMF0


4KA/4KB 1231
MN3S0/MN4S0
Pilot operated 5-port valve (pneumatic valve)
4F 1337 4SA/B0

Pilot operated 5-port valve (ISO valve) 4KA/B


PV5G/PV5/GMF/PV5S-0 1431
4KA/B (master)
Direct acting 3-port valve
2, 3-port valve 3QRA/3QRB/3QB 1505 4F

3QR negative pressure switching unit 4F (master)


MV3QRA/MV3QRB 1525
PV5G/GMF
Direct acting 3-port valve (small pneumatic valve)
3MA0/3MB0 1541 PV5/GMF

Direct acting 3-port valve (pneumatic valve) PV5S-0 (master)


3PA/3PB 1557
3QR/3QB
Pilot operated 2, 3, 5-port valve (miniature pneumatic valve)
P/M/B 1583 MV3QR
2, 3-port valve

Large flow rate 3-port valve 3MA/B0


NP/NAP/NVP 1623
3PA/B
Pilot operated explosion-proof 5-port valve
Explosion-proof 4F**0EX 1655 P/M/B

Pilot operated explosion-proof 5-port valve (pneumatic valve) NP/NAP/NVP


4F**0E 1679
Manual Explosion-proof

4F*0EX
Manual selector valve
Manual selector valve HMV/HSV 1705 4F*0E

Quick valve HMV/HSV


2QV/3QV 1713
2QV/3QV
Shock absorbing valve
Related products SKH 1723 SKH
Related products

Solenoid valve 3, 4, 5-port valve PCD


PCD 1743
Silencer
Silencer 1745 Total air systems
(Total Air)
Total air systems
Total air systems 1767 (Gamma)

Ending

Intro 4
User's Guide (How to browse/use the catalog)

Quickly search for and select a desired product using methods 1 to 4.

1
Search by product name/model No.
If the product name/model No. are already determined, the desired series page can be found.

● From INDEX ■ From page side indices

Search

I N D E X Product group Product name Page


Selection
Caution

4GA1 to 3/4GB1 to 3
Pilot operated 3, 5-port valve 4GA/B
3, 4, 5-port valve 3, 4, 5-port valve 4GA B A B 1
Guide for CKD Electronic Catalog Intro Page 1 D /4GE /MN4GD/MN4GE M4GA/B

4GA1 to 3/4GB1 to 3
Small pilot operated 3, 4-port valve
MN3E0/MN4E0 763 MN4GA/B 4GA/B
User’s Guide Intro Page 5 3, 5-port pilot operated valve (plug-in block manifold) 4GA/B (master)

Recorded position and range are displayed


W4GB2/MW4GA2/MW4GB2/MW4GZ2 863 M4GA/B
4GD/E
1 Search by product name/model No. Pilot operated 5-port valve (plug-in manifold)

Metal base MN4GA/B


W4GB4/W4GZ4/MW4GB4/MW4GZ4 1003 M4GD/E
Product name Intro Page 3
Pilot operated 4, 5-port valve Pilot operated 3, 5-portMN4GD/E
valve 4GA/B 4GA/B

by shading the model number and grid


Model No. index in alphabetic order Ending Page 38 4TB 1079
(mastr)
4GA4/B4
Pilot operated type 5-port valve (pneumatic valve)
2 Search by product series Intro Page 7 4L2-4/LMFO 1147 MN3E/MN4E 4GD/E
Select from external appearance and product description of each series.
Pilot operated 3, 4-port valve (pneumatic valve)
1165
W4GA/B2 M4GA/B M4GD/E

3, 4, 5-port valve
Master valve Intro Page 13 MN3SO/MN4S0
W4GB4
Serial transmission system Intro Page 14 Pilot operated type 5-port valve (small pneumatic valve)
1205 MN4GD/E

Metal base
4SA0/4SB0 4TB
Recommended alternative products
New products
Intro Page 15
Intro Page 16
Pilot operated type 3, 4, 5-port valve (pneumatic valve)
1231
4L2-4/LMF0 MN4GA/B 4GA4/B4
Pilot operated 3, 5-port valve
4KA/4KB
MN3S0/MN4S0

3 Search by flow characteristics C Intro Page 17


Pilot operated type 5-port valve (pneumatic valve)
4F 1337 4SA/B0 4GA/B MN3E
MN4E
Pilot operated type 5-port valve (ISO valve) 4KA/B (mastr) W4GA/B2
4 Search by specifications and variation Intro Page 29 PV5G/PV5/GMF/PV5S-0 1431
4KA/B (master)

4GD/E
Direct acting 3-port valve
2, 3-port valve 3QRA/3QRB/3QB 1505 4F W4GB4
System selection Intro Page 39
3QR negative pressure switching unit 4F (master)
"Select by cylinder bore size and operating speed" or 2, 3-port valve
MV3QRA/MV3QRB 1525 4TB
"Select by load value and operating time". PV5G/GMF

Safety precautions Intro Page 59


Direct acting 3-port valve (small pneumatic valve)
3MA0/3MB0 1541 PV5/GMF M4GD/E 4L2-4/
LMF0
Direct acting 3-port valve (pneumatic valve) PV5S-0 (master) MN3S0
* For cautions for individual products, read the cautions for the
3PA/3PB 1557
corresponding series. MN4S0
MN4GD/E
3QR/3QB
Pilot operated type 2, 3, 5-port valve (miniature pneumatic valve)
Flow characteristics display method Intro Page 58 P/M/B 1583 MV3QR 4SA/B0

2, 3-port valve
Systems Ending Page 1 Large flow rate 3-port valve 3MA/B0
1623 4KA/B
4GA4/B4
Ozone proof components Ending Page 5 NP/NAP/NVP
3PA/B
International System of Units (SI units) Ending Page 18 Pilot operated type explosion-proof 5-port valve 4KA/B
Explosion-proof 4F**0EX 1655 P/M/B
JIS symbol list Ending Page 19 (mastr)
Explosion-
● CE Marking Ending Page 30 proof Pilot operated type explosion-proof 5-port valve (pneumatic valve)
1679
NP/NAP/NVP
MN3E 4F
4F**0E CONTENTS

Manual Explosion-proof
● CKD RoHS Compliance Ending Page 32 Manual selector valve
1705
4F*0EX

4F*0E
MN4E 4F
ISO9001/ISO14001 Certification Ending Page 34 Manual selector valve HMV/HSV (mastr)
Series variation 8
W4GA/B2
Index (alphabetic order) Ending Page 38 Manual selector Quick valve HMV/HSV PV5G
2QV/3QV 1713
valve Electrical connections list (wire connections/circuit)
2QV/3QV 11 GMF
Shock absorbing valve PV5
Related products SKH 1723 SKH Product introduction 2
GMF

W4GB4
Related products

CATALOG EXPRESS Solenoid valve 3, 4, 5-port valve


1743
PCD Single valve PV5S-0
Related products PCD
Silencer
Catalogs and CAD data
Silencer 1745 Body
Total air systems piping (3GA1 to 3/4GA1 to 3) 12 3QR
(2D/3D-CAD) can be downloaded (Total Air) 3QB
from the CKD website.
http://catalog-search-e.ckd.co.jp/ Total air systems 1767
Base
Total air systems
(Gamma)
piping (3GB1 to 2/4GB1 to 3)
4TB 60
MV3QR
Ending Individual wiring manifold
Body piping (M3GA1 to 3/M4GA1 to 4L2-4/
Intro 3 Intro 4
3MA/B0
3) 96
Base piping (M3GB1 to 2/M4GB1 to LMF0
3) 112 3PA/B

Page Reduced wiring manifold MN3S0


MN4S0
P/M/B
NP/NAP/
Body piping (M3GA1 to 3-T *(D)/M4GA1 to 3-T *(D)) NVP
· Common terminal block/D sub-connector/flat cable connector/ 136
Serial transmission 4SA/B0 4F*0EX
Base piping (M3GB1 to 2-T*(D)/M4GB1 to 3-T*(D)) 4F*0E
· Common terminal block/D sub-connector/flat cable connector/
4KA/B 158 HMV

3
Serial transmission HSV
2QV

Search by flow characteristics C


Related products (in-stop valve spacer/air4KA/B
supply spacer/ 3QV
exhaust spacer/pilot check valve/silencer/plug/DIN rail) 186
(mastr) SKH
Related parts Intro Pages 17PCD
196 to 28
Manifold specifications sheet
4F 204
CONTENTS Technical data
(1) Pneumatic system selection guide 744
Silencer

If flow characteristics C have been decided, the desired series page can be found. (2) Notes on wiring
(3) Exhaust check valve
4F
(mastr)
717
751
TotAirSys
(Total Air)
TotAirSys
Series variation 8 PV5G
(4) How to expand reduced wiring manifold 736
(Gamma)

Electrical connections list (wire connections/circuit) 11 Safety precautions GMF 750 Ending

Always read the precautions in the Introduction and on page 750 before use. 7
Product introduction 2 PV5
GMF
Single valve PV5S-0
Horizontal axis:
Body piping (3GA1 to 3/4GA1 to 3) 12
3 Search by flow characteristics C Effective 3QR
cross-sectional area Search method 1 2 3 4 3QB
Search

Base piping (3GB1 to 2/4GB1 to 3) 60


Ideal model with flow characteristics C can be selected.

3
2-port 3-port 4, 5-port Related products

MV3QR
Individual wiring manifold
1 2 4
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.

Search method
*2: The port sizes listed are representative examples.
Search

Flow

3MA/B0
Wiring method
Manifold
characteristics 0 0.2 0.4 0.6 0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
C [dm3/(bar)]
Port

Single unit

Series Model No. Port size Page


Body piping (M3GA1
2 to3 3/M4GA1 4to 3) 96
Individual

Reduced

Eff. X-sectional
0 1 5 6 7 10 20 30 40 50 60 80 100 160
wiring
wiring

area (mm2)

3PA/B
Pilot operated 2-port ● P512* -
miniature pneumatic valve Base piping (M3GB1 to 2/M4GB1 to 3) 112
P512* ● B512* M5, Rc1/8
2-port 3-port 4, 5-port Related products
2-port

B512*
● M512* M5 1583
Reduced wiring manifold
M512*

P/M/B
Vertical axis:
B*P512*
N*P512* ● B*P512* M5, Rc1/8

φ4 Push-in
● N*P512*

as S ≈ 5.0 × C. NP/NAP/
fitting

Series/variation namecross-sectional
*1: Effective Body pipingarea S andtosonic
(M3GA1 conductance to
3-T *(D)/M4GA1 C are
3-Tconverted
*(D))
Direct acting 3-port small
pneumatic valve
● 3MA0
φ4 Barbed
fitting (M3)
NVP
*2: The port sizes
3M Series listed are
· Common

representative
terminal examples. cable connector/
3MB0

block/D sub-connector/flat
M3

136 1541
To the front page/index
φ4 Barbed

4F*0EX
● M3MA0
fitting (M5)

Serial transmission
0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
M3, M5


M3MB0 φ4 Push-in fitting

Series variation
φ4, φ6 Barbed fitting

Pilot operated 3-port ●


Base piping (M3GB1 to 2-T*(D)/M4GB1 to 3-T*(D))
P513* -
4F*0E
Page

miniature pneumatic valve

HMVPage
P513* ● B513* M5 × 0.8, Rc1/8

4 5 6 7 10
B513*
M513*
20 ● ·30
Common 40
M513* terminal block/D
M5
50 sub-connector/flat
60 80 cable100
connector/
160158 1583

Serial transmission HSV


B*P513*
N*P513* ● B*P513* M5, Rc1/8

φ4 Push-in

2QV
N*P513*
fitting


Direct acting 3-port valve
3QV
3QRA1 M5
3QR Series
● Related products (in-stop valve spacer/air supply spacer/
3QRB1 M5

exhaust spacer/pilot check valve/silencer/plug/DIN rail) 186


3-port

1505
● M3QRA1 M5, Rc1/8
SKH

Related parts 196
M3QRB1 M5, Rc1/8

M5

PCD
Direct acting 3-port valve MV3QRA1
φ4, φ6 Push-in fitting
1525
Manifold specifications sheet 204
MV3QR Series
M5

1583
MV3QRB1
φ4, φ6 Push-in fitting
M5
Direct acting 3-port ● 3PA1

Technical data
φ4, φ6 Push-in fitting
pneumatic valve
3P Series ● 3PA2
Rc1/8
φ6, φ8 Push-in fitting Silencer

(1) Pneumatic system selection guide
3PB1 Rc1/8
744 TotAirSys
● 3PB2 Rc1/8, Rc1/4

● (2) Notes on wiring


M3PA1
M5
φ4, φ6 Push-in fitting
717 1557 (Total Air)

(3) Exhaust check valve
M3PA2
Rc1/8
φ6, φ8 Push-in fitting
751 TotAirSys
● M3PB1
Rc1/8,
φ4, φ6 Push-in fitting (Gamma)
● (4) How to expand reduced wiring manifold
M3PB2
Rc1/8,
φ6, φ8 Push-in fitting 736
Intro 17
Safety precautions 750 Ending
Intro 18

Always read the precautions in the Introduction and on page 750 before use. 7

1541
Intro 5
22 Search byseries
product seri
Ending Page 38 to 63 Search by product Intro Pages 7 to 14
If thefrom
Select product’s series
external name is already
appearance determined,
and product description of each s
the desired series page can be found.

● In alphabetical order 3, 4, 5-port valve (pilot operated


Model No. [index in alphabetical order]
Product
2
Search mm)
Small/medium valve (10/15/18 by product series
Select from external appearance and product description of each series. NEW
Small/medium valve (10/15/18 mm)
indicates models added to the 9th edition.

Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ100 ■ Power consumption: 0


group 3, 4, 5-port valve (pilot operated type)
Small/medium valve (10/15/18 mm) Small/medium valve (10/15/18 mm)
P.1 to
Small/medium valve (10/15/18 mm)

Model No. Model Catalog Page C1040 to 8040-W W.M. combination/Standard White Series Aux comp 58 Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ100 ■ Power consumption: 0.6 W

A C1050 to 8050-W R.M. combination/Standard White Series Aux comp


C1060 to 8060-W F.M. combination/Standard White Series Aux comp
64

70
AVB**7 Air operated valve for high vacuum Flow valves Ending Page 3 C25N-B Governor for medium pressure gas Flow valves 972
AVP**2 Air operated valve for high vacuum Flow valves Ending Page 3 C3070 to 8070-W F.F.M. combination/Standard White Series Aux comp 76
AZ Tube cutter Aux comp 814 CAC4 Clamp cylinder/double acting/single rod Cylinders II 992

B CAC4-G4 Clamp cylinder/Double acting


anti-spatter adherence Cylinders II 1004
NEW
3, 5-port valve equipped with safety function
Page P.7 on NEW
3, 5-port valve equipped with safety function
Page P.221 on NEW
3, 5-port valve equipped with safety function
Page P.339 on

B Booster Cylinder Ending Page 136 CAC-N32/40 Lightweight clamp cylinder/ 4GA/4GB MN4GA/MN4GB 4GD/4GE
B*P51* I Pilot operated 2, 3, 5-port double acting/single rod Cylinders II 1030 Model No. Ports No. Specifications/port size Page Model No. Ports No. Specifications/port size Page Model No. Ports No. Specifications/port size Page
Single valve Manifold/block type (individual wiring/reduced wiring) Single valve
valve/metal base Pneu Val 1604 CAT Cartridge cylinder/single acting, push type Cylinders I 1322 3GA1 to 3 3 Body piping MN3GA 3 Body piping Individual wiring 226 3GD1 to 3 3 Body piping
12 344
4GA1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4 MN4GA 5 φ4 to Rc1/8 Reduced wiring 242 4GD1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4
B110 to 820-W Bracket/for Rotary actuator CAU30 Clean air unit Aux comp 832 3GB1 to 2 3 Base piping MN3GB 3 Base piping Individual wiring 234 3GE1 to 2 3 Base piping
60 384
F.R.L./Standard White Series Aux comp 267 CAV2 Cylinder with valve/double 4GB1 to 3 5 Rc1/8 to Rc3/8 MN4GB 5 φ4 to φ8 Reduced wiring 258 4GE1 to 3 5 Rc1/8 to Rc3/8
Manifold/metal base (individual wiring/reduced wiring) * G screws and NPT screws are also compatible. Manifold/metal base (individual wiring/reduced wiring)
B2019 Regulator Aux comp 344 acting lubrication with valve Cylinders I 694 M3GA1 to 3 3 Body piping Individual wiring 96 M3GD1 to 3 3 Body piping Individual wiring 410

Model No.
M4GA1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4 Reduced wiring 136 M4GD1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4 Reduced wiring 436
B512* S Pilot operated 2-port valve/ CAV2-N Cylinder with valve/double

Catalog name
M3GB1 to 2 3 Base piping Individual wiring 112 M3GE1 to 2 3 Base piping Individual wiring 422
sub-base Pneu Val 1588 acting no-lubrication with valve Cylinders I 694 M4GB1 to 3 5 φ4 to Rc1/4 Reduced wiring 158 M4GE1 to 3 5 φ4 to Rc1/4 Reduced wiring 456

NEW NEW
B513* S Pilot operated 3-port valve/ CCH Coolant check valve Flow valves 860
* G threads and NPT threads are also compatible.

sub-base
(Abbreviation)
Pneu Val 1588 CG Fiber tube push-in fitting
B5142 S Pilot operated 5-port valve/ (clean-room) Aux comp 802 Page P.7 on Page P.22
Page
sub-base Pneu Val 1588 CHB Air operated 2-port ball valve
B6061 Relief valve Aux comp 348 (compact rotary valve)/double acting Flow valves 662

B7019
BBS-A
F.R. unit Aux comp 338
Balancer unit, automatic pressure adjustment Cylinders II 1216
CHBF Air operated 2-port ball valve (compact
rotary valve)/double acting/full bore Flow valves 662
3, 5-port valve equipped with safety function 3, 5-port valve equipped with safety functio

4GA/4GB MN4GA/MN4GB
CHBF-R* Air operated 2-port ball valve (compact
BBS-O Balancer unit, fixed pressure adjustment Cylinders II 1228 Small/medium valve (10/15/18 mm) Large valve (24 mm) Small valve (7.0/10 mm)
rotary valve)/single acting/full bore Flow valves 662
BHA Compact cross roller parallel hand Cylinders II 1506
CHBF-V* Air operated 2-port ball valve (compact rotary Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ160 ■ Power consumption: 1.0 W Cylinders up to φ32 ■ Power consumption: 0.4 W and up

BHA-FC Mechanical hand Cylinders II 1735 valve)/with solenoid valve/double acting/full bore Flow valves 676
CHBF-X*
Model No. Ports No. Specifications/port size Pa
BHA-LN Air operated 2-port ball valve (compact rotary
Model No. Ports No. Specifications/port size Page
Hand with length measuring sensor/
cross roller parallel hand with sensor Cylinders II 1444 valve)/with solenoid valve/single acting/full bore Flow valves 676

Manifold/block type (individual wiring/reduced w


CHB-R* Air operated 2-port ball valve
BHE
BHE-LN
Centering hand
Hand with length measuring
Cylinders II 1624
(compact rotary valve)/single acting Flow valves 662 Single valve
CHB-V* Air operated 2-port ball valve (compact rotary
sensor/centering hand with sensor Cylinders II 1444
valve)/with solenoid valve/double acting Flow valves 676 3GA1 to 3 3 Body
NEW piping Page P.511 on Page P.599 on MN3GA 3 Body piping Individual
Page P.763 on
BHG Compact cross roller parallel hand with rubber cover Cylinders II 1506
CHB-X* Air operated 2-port ball valve (compact rotary 12
3, 5-port valve equipped with safety function Large flow rate 5-port valve 3, 4-port valve with valve height of 40 mm or less
BHG-LN Hand with length measuring sensor/rubber
covered cross roller parallel hand with sensor Cylinders II 1444
valve)/with solenoid valve/single acting Flow valves 676 4GA1 to 3 5 φ4MN4GD/MN4GE
to φ10, M5, Rc1/8, 1/44GA4/4GB4 MN4GA
MN3E/MN4E 5 φ4 to Rc1/8 Reduced
Model No. Ports No. Specifications/port size Page Model No. Ports No. Specifications/port size Page Model No. Ports No. Specifications/port size Page
CHC Auto hand changer Cylinders II 1724
BSA2
3GB1 to 2 3 Base piping MN3GB 3 Base piping Individual
Miniature cross roller parallel hand Cylinders II 1496 Manifold/block type (individual wiring/reduced wiring) Single valve Block manifold (reduced wiring)
CHG Air operated 3-port ball valve MN3GD 3 Body piping Individual wiring 516 Body piping MN3E00 3

C 60
4GA4 5 606 M3 to φ4 772
MN4GD 5 φ4 to Rc1/8 Reduced wiring 532 φ8 to φ12, Rc3/8

MN4GB 5 φ4 to φ8 Reduced
(compact rotary valve)/double acting Flow valves 670 MN4E00 4

4GB1 to 3 5 Rc1/8 to Rc3/8


MN3GE 3 Base piping Individual wiring 524 Base piping

Model No. Page


4GB4 5 618 Block manifold (individual wiring/reduced wiring)
MN4GE 5 φ4 to φ8 Reduced wiring 548 Rc3/8, Rc1/2
CHG-R* Air operated 3-port ball valve
MN3E0 3
Manifold/metal base (individual wiring/reduced wiring)
C1000 to 8000-P6 F.R.L. combination/copper and PTFE free series Aux comp 238 (compact rotary valve)/single acting Flow valves 670 M5 to φ6 796
Body piping Individual wiring 630

Manifold/metal base (individual wiring/reduced wiring)


M4GA4 5 MN4E0 4
C1000 to 8000-W F.R.L. combination/Standard White Series Aux comp
* G screws and NPT screws are also compatib
φ8 to φ12, Rc3/8 Reduced wiring 662
32 CHG-V* Air operated 3-port ball valve (compact rotary
Base piping Individual wiring 644
M4GB4 5
C1010 to 8010-W W.L. combination/Standard White Series Aux comp 40 valve)/with solenoid valve/double acting Flow valves 682 φ8 to φ12, Rc1/4 to Rc1/2 Reduced wiring 678

C1020 to 8020-W F.R. combination/Standard White Series Aux comp 46


CHG-X* Air operated 3-port ball valve (compact rotary
valve)/with solenoid valve/single acting Flow valves 682
M3GA1 to 3 3 Body piping Individual wiring 96 * G threads and NPT threads are also compatible.

C1030 to 8030-W F.M.R. combination/Standard White Series Aux comp


M4GA1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4 Reduced wiring 136
52 Intro 7
Ending CHL Check valve with push-in fitting Aux comp 710

Ending 42
M3GB1 to 2 3 Base piping Individual wiring 112
M4GB1 to 3 5 φ4 to Rc1/4 Reduced wiring 158
* G threads and NPT threads are also compatible.

4
Search by specifications and variation
If the variation format is already determined,
Intro Page 29 to 38
Icons (marks)
the desired product can be found.

ForSmall/medium
easier use of the catalog, each
valve (10/15/18 mm)
item is
Large valve (24 mm)

fications and
4 variation Also known as... Search by specifications and variation
marked and
Cylinders up

in the text.
compatible
to φ100 items
■ Power consumption: 0.6 W are indicated
Cylinders up to φ160 ■ Power consumption: 1

Individual wiring manifold


Flow characteristic C Effective cross-sectional area
Series name Manifold model No. [dm3/(s·bar)] (mm2) Remarks Page
4, 5-port valve
MN4E0 Series MN4E0 0.5 to 0.54 -
One-sided
solenoid type
796 Mark Meaning Details
4S0 Series M4SA0 - 0.9
1218
(small pneumatic valve) M4SB0 0.29 to 0.32 -
M4G DA 96/410
0.70 to 8.0
M4G BE 112/422
4G Series -
MN4G DA 226/516
0.71 to 2.3
MN4G BE 234/524

CAD data is available for


MW4GA2 One-sided 874
W4G2 Series MW4GB2 1.7 to 2.3 - solenoid/ 878
MW4GZ2 plug-in type 878
Flow characteristic C Effective
Pilot cross-sectional area
old model No. Remarks Page
operated
W4G4 Series MW4GB4 6.4 to 7.4 - Plug-in type 1010

items with CAD marks in Intro Page 1


soft spool valve
[dm3/(s·bar)] (mm2)

NEW
MN4S0 Series MN4S0 One-sided
0.57 to 0.80 - 1170

port valve
(pneumatic valve) MT4S0 solenoid type
M4KA 1272
4K Series
(pneumatic valve)
M4KB 0.60 to 11 - 1284
dimensions.Page P.511 on Page P.59
One-sided
MN4KB 1304

To the
(A)M4F0
0 0.5 to 0.54 - 4F Series M4F1 to M4F3
796 160
1376

solenoid type 3, 5-port valve equipped with safety function Large flow rate 5-port valve
0.6 to 18
(pneumatic valve) M4F4 to 7 (4F7) 1404

corresponding page
M4F**E Explosion-proof 1694

MN4GD/MN4GE
GMF1 1450

4GA4/4GB4
PV5G/PV5/CMF Series

0 - 0.9
2.8 to 11.6 -
(ISO valve) GMF2 1454
2, 3-port valve
1218
0 0.29 to 0.32 - MN3E0 Series MN3E0

M3GA
0.54

0.70 to 2.5
- One-sided 796

96
Pilot operated
soft spool valve
3G Series
96/410
MN3GA 0.71 to 1.7
-
226 Model No. Ports No. Specifications/port size Page Model No. Ports No. Specifications/port size Pa
0.70 to 8.0
MN3S0 Series MN3S0 One-sided

European Standards compliant


0.80 - 1170
(pneumatic valve) MT3S0 solenoid type
Manifold/block type (individual wiring/reduced wiring) Single valve
3K Series
112/422
M3KA

Ending Page 30piping


0.69 - 1272

-
(pneumatic valve)

A MN3GD 3 Body piping Individual wiring 516 Body


products.
3M Series M3MA0

D
(small pneumatic valve)
226/516
M3MB0
- 0.1 to 0.5 1546
4GA4 5
B 0.71 to 2.3 Direct acting poppet
3QR Series
M3QRA
0.30 to 0.40 - 1528 MN4GD 5 φ4 to Rc1/8 Reduced wiring 532 φ8 to φ12, Rc3/8
234/524
valve M3QRB

E 3P Series M3PA
(pneumatic valve) M3PB
0.31 to 1.1 - 1570
MN3GE 3 Base piping Individual wiring 524 Base piping
A2 Pilot operated P/M/B Series
One-sided 874
B*P51
0.09 to 0.15 -
1588
4GB4 5
poppet valve (Miniature pneumatic valve)
Two 3-port valves integrated
N*P512/3/4 1610
MN4GE 5 φ4 to φ8 Reduced wiring 548 Rc3/8, Rc1/2
B2 1.7 to 2.3 - MN3E0 Seriessolenoid/ 878
MN3E0 0.5 - One-sided 796
Manifold/metal base (individual wiring/reduced wiring)
plug-in type
M3G DA 96/410

Z2 Pilot operated
878
M3G BE 112/422
Body piping Individual w
Vertical axis:
3G Series 0.66 to 1.7 -
soft spool valve MN3G DA 226/516
MN3G BE 234/524 M4GA4 5
MN3S0 Series MN3S0 One-sided φ8 to φ12, Rc3/8 Reduced w
B4 6.4 to 7.4 Series
- nametype
Plug-in 1010
0.50 - 1170
(pneumatic valve) MT3S0 solenoid type

Base piping Individual w


Note: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 x C.

RoHS-compliant products. M4GB4 Ending 5 Page 32


φ8 to φ12, Rc1/4 to Rc1/2 Reduced w
0 Intro 29
One-sided
0.57 to 0.80 - 1170
0 solenoid type * G threads and NPT threads are also compat
1272
0.60 to 11 - 1284
Intro 7
B 1304 Intro 6
F0
1376
o M4F3 160
0.6 to 18
2 Search by product series
Select from external appearance and product description of each series. NEW indicates models added to the 9th edition.

3, 4, 5-port valve (pilot operated) P.1 to


Small/medium valve (10/15/18 mm) Small/medium valve (10/15/18 mm) Small/medium valve (10/15/18 mm)
Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ100 ■ Power consumption: 0.6 W

NEW Page P.7 on NEW Page P.221 on NEW Page P.339 on

3, 5-port valve equipped with safety function 3, 5-port valve equipped with safety function 3, 5-port valve equipped with safety function

4GA/4GB MN4GA/MN4GB 4GD/4GE


Model No. No. of Ports Specifications/port size Page Model No. No. of Ports Specifications/port size Page Model No. No. of Ports Specifications/port size Page
Single valve Manifold/block (individual wiring/reduced wiring) Single valve
3GA1 to 3 3 Body piping MN3GA 3 Body piping Individual wiring 226 3GD1 to 3 3 Body piping
12 344
4GA1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4 MN4GA 5 φ4 to Rc1/8 Reduced wiring 242 4GD1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4
3GB1 to 2 3 Base piping MN3GB 3 Base piping Individual wiring 234 3GE1 to 2 3 Base piping
60 384
4GB1 to 3 5 Rc1/8 to Rc3/8 MN4GB 5 φ4 to φ8 Reduced wiring 258 4GE1 to 3 5 Rc1/8 to Rc3/8
Manifold/metal base (individual wiring/reduced wiring) * G screws and NPT screws are also compatible. Manifold/metal base (individual wiring/reduced wiring)
M3GA1 to 3 3 Body piping Individual wiring 96 M3GD1 to 3 3 Body piping Individual wiring 410
M4GA1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4 Reduced wiring136 M4GD1 to 3 5 φ4 to φ10, M5, Rc1/8, 1/4 Reduced wiring 436
M3GB1 to 2 3 Base piping Individual wiring112 M3GE1 to 2 3 Base piping Individual wiring 422
M4GB1 to 3 5 φ4 to Rc1/4 Reduced wiring158 M4GE1 to 3 5 φ4 to Rc1/4 Reduced wiring 456
* G threads and NPT threads are also compatible.

Small/medium valve (10/15/18 mm) Large valve (24 mm) Small valve (7.0/10 mm)
Cylinders up to φ100 ■ Power consumption: 0.6 W Cylinders up to φ160 ■ Power consumption: 1.0 W Cylinders up to φ32 ■ Power consumption: 0.4 W and up

NEW Page P.511 on Page P.599 on Page P.763 on

3, 5-port valve equipped with safety function Large flow rate 5-port valve 3, 4-port valve with valve height of 40 mm or less

MN4GD/MN4GE 4GA4/4GB4 MN3E/MN4E


Model No. No. of Ports Specifications/port size Page Model No. No. of Ports Specifications/port size Page Model No. No. of Ports Specifications/port size Page
Manifold/block (individual wiring/reduced wiring) Single valve Block manifold (reduced wiring)
MN3GD 3 Body piping Individual wiring 516 Body piping MN3E00 3
4GA4 5 606 M3 to φ4 772
MN4GD 5 φ4 to Rc1/8 Reduced wiring 532 φ8 to φ12, Rc3/8
MN3GE 3 Base piping Individual wiring 524 MN4E00 4
Base piping
4GB4 5 618 Block manifold (individual wiring/reduced wiring)
MN4GE 5 φ4 to φ8 Reduced wiring 548 Rc3/8, Rc1/2
Manifold/metal base (individual wiring/reduced wiring) MN3E0 3
M5 to φ6 796
Body piping Individual wiring 630
M4GA4 5 MN4E0 4
φ8 to φ12, Rc3/8 Reduced wiring 662
Base piping Individual wiring 644
M4GB4 5
φ8 to φ12, Rc1/4 to Rc1/2 Reduced wiring 678
* G threads and NPT threads are also compatible.

Intro 7
Search method 1 2 3 4
3, 4, 5-port valve (pilot operated) 3-port valve (direct acting) 2, 3-port valve (pilot operated) Explosion-proof
2, 3-port valve (for air blow) Master valve Manual selector valve Related products Serial transmission system

Medium valve (manifold pitch 16 mm) Large valve (manifold pitch 25 mm) One-sided solenoid/reduced wiring valve
Cylinders up to φ80 ■ Power consumption: 0.6 W Cylinders up to φ125 ■ Power consumption: 1.2 W Cylinders up to φ180 ■ Power consumption: 1.9 W

Page P.863 on Page P.1003 on Page P.1079 on

IP65 compatible plug-in block manifold 3, 5-port valve IP65 equivalent plug-in manifold 5-port valve Plug-in type block manifold 4, 5-port valve

W4G2 W4G4 4TB


Model No. No. of Ports Specifications/port size Page Model No. Specifications/port size Page Model No. No. of Ports Specifications/port size Page
Single valve Single valve Single valve
Base piping Base piping 4TB3 5 Sub-plate piping
W4GB2 5 870 W4GB4 1010 1084
Rc1/4 Rc1/4, Rc3/8 4TB4 Rc1/4 to Rc1/2
Individual wiring manifold Base piping Reduced wiring manifold
W4GZ4 1010
MW3GA2-R1 3 Body piping Rc1/4, Rc3/8 MN4TB1 4 DIN rail
874 1090
MW4GA2-R1 5 Rc1/8, φ4 to φ8 Individual wiring manifold MN4TB2 φ4 to φ10
MW4GB2-R1 5 Base side piping MW4GB4-R1 Base side piping M4TB3 5 Direct mounting method
878 1016 1100
φ4 to φ8 φ8 to φ12, Rc1/4 , Rc3/8 M4TB4 Rc1/4 to Rc1/2
MW4GZ2-R1 5 Base bottom piping MW4GZ4-R1 Base bottom piping
878 1016
φ4 to φ8 Rc1/4, Rc3/8
Reduced wiring manifold Reduced wiring manifold
MW3GA2-T* 3 Body piping MW4GB4-T* Base side piping
884 1020
MW4GA2-T* 5 Rc1/8, φ4 to φ8 φ8 to φ12, Rc1/4, Rc3/8
MW4GB2-T* 5 Base side piping MW4GZ4-T* Base bottom piping
906 1020
φ4 to φ8 Rc1/4, Rc3/8
MW4GZ2-T* 5 Base bottom piping
906 * G screws and NPT screws are also compatible.
φ4 to φ8

Reduced wiring valve One-sided solenoid/reduced wiring valve Small (valve width 10 mm)
Cylinders up to φ80 ■ Power consumption: 1.8 W Cylinders up to φ40 ■ Power consumption: 0.6 W Cylinders up to φ25 ■ Power consumption: 0.6 W

Page P.1147 on Page P.1165 on Page P.1205 on


Plug-in type 5-port valve Block manifold 3, 4-port valve Miniature/space saving 5-port valve
4L2-4/LMFO (pneumatic valve) MN3S0/MN4S0 ( pneumatic
Valve ) 4SA0/4SB0 (small pneumatic valve)
Model No. Specifications/port size Page Model No. No. of Ports Specifications/port size Page Model No. Specifications/port size Page
Single valve Block manifold (individual wiring/reduced wiring) Single valve
4L2-4 Sub-plate piping MN3S0 3 DIN rail 4SA0 Body piping
1150
Rc1/4 MN4S0 4 M5 to φ6 M3, φ4
1170 1210
Reduced wiring manifold MT3S0 3 Direct mounting 4SB0 Sub-plate piping
LMF0 Sub-plate piping MT4S0 4 M5 to φ6 M5
1150
φ4 to Rc1/4 Manifold (individual wiring/reduced wiring)
M4SA0 Body piping
Individual wiring 1218
M3, φ4
M4SB0 Sub-plate piping Individual wiring 1218
M5, φ4 to φ6 Reduced wiring 1222

Intro 8
2 Search by product series
Select from external appearance and product description of each series. NEW indicates models added to the 9th edition.

3, 4, 5-port valve (pilot operated) P.1 to


Small/medium/large valve (valve width 15/18/23/29 mm) Small/medium/large valve ISO Standards compliant valve
Cylinders up to φ160 ■ Power consumption 1.8 W Cylinders up to φ250 ■ Power consumption: 1.8 to 6 W Cylinders up to φ160 ■ Power consumption: 1.0, 1.2 W

Page P.1231 on Page P.1337 on Page P.1437 on


Compact 3, 4, 5-port valve 8 series lined-up / 5-port valve Valve width 38 to 50 mm / 5-port valve

4KA/4KB (pneumatic valve) 4F (pneumatic valve) PV5G/GMF (DIN terminal box)


Model No. No. of Ports Specifications/port size Page Model No. Specifications/port size Page Model No. Specifications/port size Page
Single valve Single valve Single valve (sub-plate piping)
3KA1 3 Body piping 4F0 to 3 Body piping PV5G-6 ISO size 1
1238 1344 1438
4KA 5 M5 to φ12 M5, Rp1/8 to Rp3/8 Rc1/4, Rc3/8
4KB 5 Sub-plate piping 4F4 to 7 Sub-plate piping PV5G-8 ISO size 2
1256 1358 1444
Rc1/8 to Rc1/2 Rc1/4 to Rc1 Rc3/8 to Rc3/4
Individual wiring manifold/metal base Individual wiring manifold Individual wiring manifold
M3KA1 3 Body piping M4F0 to 3 Body piping GMF1 ISO size 1
1272 1376 1450
M4KA 5 M 5 t o φ1 2 M5, Rp1/8 to Rp3/8 Rc1/4, Rc3/8
M4KB 4 Sub-plate piping M4F4 to 7 Sub-plate piping GMF2 ISO size 2
1284 1404 1454
5 M5 to φ12 Rc1/4 to Rc3/4 Rc3/8, Rc1/2
Individual wiring manifold/block * A4F0 . . . Model No. for the 4F0 single type. Mix manifold
MN4KB 5 Sub-block piping GMFZ ISO sizes 1/2
1304 1458
φ4 to φ10 Mix manifold

ISO Standards compliant valve ISO compliant master valve


Cylinders up to φ160 ■ Power consumption: 1.2 W Cylinders up to φ160

Page P.1465 on Page P.1493 on


Valve width 38 to 50 mm / 5-port valve Valve width 38 to 50 mm / 5-port valve

PV5/GMF (I/O connector) PV5S-0 (ISO compliant master valve)


Model No. Specifications/port size Page Model No. Specifications/port size Page
Single valve (sub-plate piping) PV5S-6-0
Rc1/4, Rc3/8
PV5-6R ISO size 1
1466 1494
Rc1/4, Rc3/8 PV5S-8-0 Rc3/8, Rc1/2,
PV5-8R ISO size 2 Rc3/4
1472
Rc3/8 to Rc3/4
Individual wiring manifold
GMF1 ISO size 1
1478
Rc1/4, Rc3/8
GMF2 ISO size 2
1482
Rc3/8, Rc1/2
Mix manifold
GMFZ ISO sizes 1/2
1486
Mix manifold

Intro 9
Search method 1 2 3 4
3, 4, 5-port valve (pilot operated) 3-port valve (direct acting) 2, 3-port valve (pilot operated) Explosion-proof
2, 3-port valve (for air blow) Master valve Manual selector valve Related products Serial transmission system

3-port valve (direct acting) P.1505 to


Small valve (valve width 10mm) Small valve (valve width 10mm) Small valve (valve width 10mm)
Cylinders up to φ25 ■ Power consumption: 2.0 to 2.4 W Cylinders up to φ25 ■ Power consumption: 2.0 to 2.4 W Cylinders up to φ16 ■ Power consumption: 0.6 W

Page P.1505 on NEW Page P.1525 on Page P.1541 on

Poppet type 3-port valve Poppet type 3-port valve Poppet type 3-port valve

3QRA/3QRB MV3QRA/MV3QRB 3MA0/3MB0 (small pneumatic valve)


Model No. Specifications/port size Page Model No. Specifications/port size Page Model No. Specifications/port size Page
Single valve MV3QRA1 Body piping Single valve
3QRA Body piping M5Nφ6 3MA0 Body piping
1528
M5 MV3QRB1 Sub-plate piping φ4
1510 1544
3QRB Sub-plate piping M5Nφ6 3MB0 Sub-plate piping
M5 M3
Individual wiring manifold Individual wiring manifold
M3QRA Body piping M3MA0 Body piping
M5 to Rc1/8 φ4
1510 1546
M3QRB Sub-plate piping M3MB0 Sub-plate piping
M5 to Rc1/8 φ4, φ6, M3, M5

2, 3-port valve (pilot operated) P.1583 to


Small valve (valve width 15/22 mm) Small valve (valve width 15 mm) Large flow rate
Cylinders up to φ40 ■ Power consumption: 1.8 W Port size M5, Rc1/8, φ4 ■ Power consumption 1.8 W Port size Rc3/8 to Rc2 ■ Power consumption 4 to 8 W / DC

Page P.1557 on Page P.1583 on Page P.1623 on


Pressure balance poppet valve Poppet type 2, 3, 5-port valve 3-port pneumatic/low-vacuum valve

3PA/3PB (pneumatic valve) P/M/B (miniature pneumatic valve) NP/NAP/NVP


Model No. Specifications/port size Page Model No. Specifications/port size Page Model No. Specifications/port size Page
Single valve W2P513 Two 3-port valves integrated NP13/14 Internal pilot solenoid valve
1626
3PA Body piping M5 Rc3/8 to Rc2
M5 to Rc1/8 P512* P513* No sub-base NAP11 Internal pilot air operated
1562 1632
3PB Sub-plate piping P5142 Rc3/8 to Rc2
1588
Rc1/8 to Rc1/4 M512* Sub-base NVP11 External pilot solenoid valve
1636
Individual wiring manifold M513* M5 Rc3/8 to Rc2
M3PA Body piping B512* B513* Sub-base M5
M5 to Rc1/4 B5142
1570
M3PB Sub-plate piping Individual wiring manifold
Rc1/8 to Rc1/4 B*P51** Sub-base
1604
M5, Rc1/8
Block manifold
N*P51** Sub-block
1610
φ4

Intro 10
2 Search by product series
Select from external appearance and product description of each series. NEW indicates models added to the 9th edition.

Explosion-proof P.1655 to
Pilot operated 5-port valve Pilot operated 5-port valve
Cylinders up to φ250 ■ Power consumption: 4 to 4.5 W Cylinders up to φ250 ■ Power consumption: 4 to 4.5 W

NEW Page P.1655 on Page P.1679 on


Explosion proof performance ExdIIBT4 Pressure and explosion proof enclosure d2G4 type

4F**0EX (pneumatic valve) 4F**0E (pneumatic valve)


Model No. Specifications/port size Page Model No. Specifications/port size Page
Single valve Single valve
4F3*0EX Body piping 4F3*0E Body piping
1658 1682
Rp1/4 to Rp3/8 Rp1/4 to Rp3/8
4 4
4F to *0EX Sub-plate piping 4F to*0E Sub-plate piping
1658 1682
7 Rc1/4 to Rc1 7 Rc1/4 to Rc1
Manifold Manifold
M4F3*0EX Body piping M4F3*0E Body piping
1668 1694
Rp1/4 to Rp3/8 Rp1/4 to Rp3/8
4 4
M4F to *0EX Sub-plate piping M4F to *0E Sub-plate piping
1668 1694
7 Rc1/4 to Rc3/4 7 Rc1/4 to Rc3/4

Explosion-proof 2, 3-port valve General Purpose Valves

Direct acting poppet type 2, 3-port valve Pilot operated poppet type 2-port valve Poppet type 2-port valve
■ Power consumption: 6.7 to 17 W (60 Hz) ■ Power consumption: 6.7 to 17 W (60 Hz) ■ Power consumption: 7 W (60 Hz)

Pressure and explosion proof enclosure d2G4/d2G2 type Pressure and explosion proof enclosure d2G4/d2G2 type Pressure and explosion proof enclosure d2G4 type for air blow

AB/AG (general purpose valve) AD/AP (general purpose valve) PDVE4 (pulse-jet valve)
Model No. Port size Page Model No. Port size Page Model No. Port size Page
2-port valve AP**E4 Rc 1/2 to 50 flange General Purpose
PDVE4 Rc3/4 to Rc2
AB4*E4 Rc1/4, Rc3/8 AD**E4 Rc 1/2 to 50 flange General Purpose Valves
General Purpose
AB41E2 Rc1/4, Rc3/8 ADK**E4 Rc1/2 to Rc1 Valves
Valves
AB41E4-Z Rc1/4, Rc3/8 AP**E2 Rc 1/2 to 50 flange
3-port valve
AG4*E4 Rc1/4, Rc3/8 General Purpose
AG4*E4-Z Rc1/4, Rc3/8 Valves

Intro 11
Search method 1 2 3 4
3, 4, 5-port valve (pilot operated) 3-port valve (direct acting) 2, 3-port valve (pilot operated) Explosion-proof
2, 3-port valve (for air blow) Master valve Manual selector valve Related products Serial transmission system

2, 3-port valve (air blow type) General Purpose Valves

Compact poppet valve Compact poppet valve Compact poppet valve


■ Power consumption: 3 to 11.5 W/DC ■ Power consumption: 3 to 11.5 W/DC ■ Power consumption: 3.8 to 11 W (60 Hz)

Direct acting 2-port valve by target fluid Direct acting 3-port valve by target fluid General purpose direct acting 2, 3-port valve

FA/FG/FV (special purpose valve) FA/FG (special purpose valve) AB/AG (general purpose valve)
Model No. Working fluid/port size Page Model No. Working fluid/port size Page Model No. Port size Page
Single valve Single valve Single valve/2-port valve
FAB For compressed air FAG For compressed air AB Rc1/8 to Rc1/2
General
M5 to Rc1/2 M5 to Rc3/8 Manifold/2-port valve
General Purpose
FGB For dry air FGG For dry air GAB Rc1/4
Purpose Valves General
Rc1/8 to 1/2 Rc1/8 to 3/8 Single valve/large bore size 2-port valve
Valves Purpose
FVB For medium vacuum Manifold AB71 Rc1/2 to Rc1
Valves
Rc1/8 to 1/2 GFAG For compressed air Single valve/3-port valve
General
Manifold M5 to Rc1/4 AG Rc1/8 to Rc3/8
Purpose
GFAB For compressed air GFGG For dry air Manifold/3-port valve
Valves
M5 to Rc3/8 Rc1/8 to 1/4 GAG Rc1/8 to Rc3/8
General
GFGB For dry air
Purpose
M5 to Rc3/8
Valves
GFVB For medium vacuum
M5 to Rc3/8

Large poppet type Miniature poppet valve Medium poppet type


■ Power consumption: 3.8 to 48W (60 Hz) ■ Power consumption 0.6 W (DC) ■ Power consumption: 3.4 to 10W (60 Hz)

General purpose pilot operated 2-port valve 2-port valve for air blow Pilot operated 2-port valve for large flow rate air blow

AD/AP (general purpose valve) EXA PD/PDV (pulse-jet valve)


Model No. Port size Page Model No. Port size Page Model No. Port size Page
Piston drive Pilot operated Air operated valve
AP11/12 8A to 25 A General Purpose PD3 Rc3/4 to Rc3
EXA φ6 to φ12
AP21/22 Rc1 1/4 to 50 flange Valves PD2 Rc2
Diaphragm drive Solenoid valve
General General
AD11/12 8 A to 25 A PDV3 Rc3/4 to Rc3
Purpose Purpose
AD21/22 Rc1 1/4 to 50 flange PDV2 Rc2
Valves Valves
Pilot kick piston drive Multiple-series solenoid valve for PD3 operation (direct acting)
APK11/21 Rc 1/4 to 50 flange PJVB Rc1/8, Rc1/4
Pilot kick diaphragm drive Controller for pulsejet valve
ADK11/12/21 Rc 1/4 to 50 flange OMC2 Output step No.: 6, 10

Intro 12
2 Search by product series
Select from external appearance and product description of each series. NEW indicates models added to the 9th edition.

Master valve
3, 5-port valve 3, 5-port valve 5-port valve
Cylinders of φ20 to φ100 Cylinders of φ20 to φ160 Cylinders of φ10 to φ250

NEW Page P.315 on Page P.1323 on Page P.1419 on

4G 4K (pneumatic valve) 4F (pneumatic valve)


Model No. Specifications/port size Page Model No. Specifications/port size Page Model No. Specifications/port size Page
Single valve Single valve Single valve
3GA Body piping 3KA1 Body piping 4F0 to 3 Body piping
318 1324 1420
4GA φ4 to Rc1/4 4KA M5 to φ12 4F4 to 7 Sub-plate piping
4GB Base piping 4KB Sub-plate piping Manifold
328 1330
Rc1/8 to Rc3/8 Rc1/8 to Rc1/2 (A)M4F0 to 3 Body piping
1420
Manifold Manifold M4F4 to 7 Sub-plate piping
M3GA Body piping M3KA1 Body piping
318 1324
M4GA φ4 to Rc1/4 M4KA M5 to φ12
M4GB Base piping M4KB Sub-plate piping
328 1330
φ4 to Rc1/4 M5 to φ12

Manual selector valve Related products


Manual override switching 4-port valve
Cylinders of φ20 to φ160 With push-in fitting φ25 to φ125 cylinder

Page P.1705 on Page P.1713 on Page P.1723 on

Slide valve, manual switching valve Quick valve Shock absorbing valve

HMV/HSV 2QV/3QV SKH


Model No. Port size Page Model No. Port size Page Model No. Specifications Page
HMV Miniature 2QV 2-way valve SKH Variable speed unit
1708 1714
Rc1/4 3QV 3-way valve SKH Deceleration unit 1726
HSV Standard SKH Single-side deceleration unit
1708
Rc1/4 to 3/4

Solenoid valve 3, 4, 5-port valve

PCD Page P.1743 on


Model No. Specifications Page
PCD Pilot operated poppet 3, 4, 5-port valve 1744

Intro 13
Search method 1 2 3 4
3, 4, 5-port valve (pilot operated) 3-port valve (direct acting) 2, 3-port valve (pilot operated) Explosion-proof
2, 3-port valve (for air blow) Master valve Manual selector valve Related products Serial transmission system

Related products

Page P.1745 on

Silencer Total air systems


[Total air systems]
Total air systems
[Gamma system]
Series Piping bore size Page Model No. Specifications/port size Page Page
Metering valve with silencer Detector (mechanical valve) PLC components
1811
SMW2 R1/8, 1/4 1748 MS Small Rc1/8, φ4 Signal control components
FMS M5 MM Medium Rc1/8, φ4
1750 1769
SMW R3/8, 1/2 MAVL Large Rc1/4
Small bore size Circuit device (logic valve)
SL M5 1752 φ4
Resin body
SLW R1/8, 1/4, 3/8, 1/2 1752
SLW-*A-H R1/4, 3/8, 1/2 1754
Large flow rate/small bore size/resin body
SLW-*L R1/4, 3/8 1755
High noise reduction/compact
R1/8, 1/4 1756
SLW-*S
R3/4 1757
Push-in
SLW-H R1/4, 3/8, 1/2 1758
Miniature
SLM
Aluminum body
M3, M5 1759 Serial transmission system
SL R1/4 to 2 1760
Exhaust cleaner
FA*31 Rc3/8 to 2 1764

[Serial transmission system]


Model No. Specifications Page Model No. Specifications
OPP2 Degree of protection (IP64) UNIWIRE ○
R SYSTEM

OPP3 Flat cable compatible slave unit UW Serial parallel transmission system
OPP4 Thin shape SAVE NET
OPP5 Degree of protection (IP65) CSN High speed transmission system
Intro Page 31
I/O block compatible
OPP6 Miniature 32 point compatible
NEW OPP7 Thin 32 point compatible
NEW OPP8 Thin 32 point compatible

Intro 14
Recommended alternative products
Production of the series below has been discontinued.
Select recommended alternative products instead.

Discontinued Recommended alternative product

■ 3, 5-port pilot operated valve (small pneumatic valve) ■ Pilot operated 3, 5-port valve

4SA1/4SB1 Series 4G R Series

■ Direct acting 3, 5-port valve ■ Pilot operated 5-port valve

FS/FD Series 4F Series

■ Pilot operated 5-port valve (ISO valve) ■ Pilot operated 5-port valve (ISO valve)

CMF Series GMF Series

■ Pilot operated 3, 5-port valve ■ Pilot operated 3, 5-port valve

4G Series 4G R Series

Intro 15
New products
The new series below are now available.

■ Pilot operated 3, 5-port valve


4GA/B/4GD/ER Series

■ 3QR negative pressure switching unit


MV3QRA1/MV3QRB1 Series

■ Pilot operated explosion-proof 5-port valve


4F**0EX Series

Intro 16
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.

Wiring method Flow


Manifold
characteristics 0 0.2 0.4 0.6
C [dm3/(bar)]
Port

Single unit
Series Model No. Port size

Individual

Reduced
Eff. X-sectional
0 1 2 3

wiring
wiring
area (mm2)

Pilot operated 2-port ● P512* -


miniature pneumatic valve
P512* ● B512* M5, Rc1/8
2-port

B512*
M512* ● M512* M5
B*P512*
N*P512* ● B*P512* M5, Rc1/8

φ4 Push-in
● N*P512*
fitting
φ4 Barbed
Direct acting 3-port small ● 3MA0
fitting (M3)
pneumatic valve
● 3MB0 M3
3M Series
φ4 Barbed
● M3MA0
fitting (M5)
M3, M5
● M3MB0 φ4 Push-in fitting
φ4, φ6 Barbed fitting

Pilot operated 3-port ● P513* -


miniature pneumatic valve
P513* ● B513* M5 × 0.8, Rc1/8
B513*
M513* ● M513* M5
B*P513*
N*P513* ● B*P513* M5, Rc1/8

φ4 Push-in
● N*P513*
fitting

Direct acting 3-port valve ● 3QRA1 M5


3QR Series
● 3QRB1 M5
3-port

● M3QRA1 M5, Rc1/8

● M3QRB1 M5, Rc1/8

M5
Direct acting 3-port valve ● MV3QRA1
φ4, φ6 Push-in fitting
MV3QR Series
M5
● MV3QRB1
φ4, φ6 Push-in fitting
M5
Direct acting 3-port ● 3PA1
φ4, φ6 Push-in fitting
pneumatic valve Rc1/8
3P Series ● 3PA2
φ6, φ8 Push-in fitting

● 3PB1 Rc1/8

● 3PB2 Rc1/8, Rc1/4

M5
● M3PA1
φ4, φ6 Push-in fitting
Rc1/8
● M3PA2
φ6, φ8 Push-in fitting
Rc1/8,
● M3PB1
φ4, φ6 Push-in fitting
Rc1/8,
● M3PB2
φ6, φ8 Push-in fitting

Intro 17
Search method 1 2 3 4

Search
2-port 3-port 4, 5-port Related products

*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.

0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160

1583

1541

1583

1505

1525

1557

Intro 18
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.

Wiring method Flow


Manifold
characteristics
C [dm3/(bar)]
0 0.2 0.4 0.6
Port

Single unit
Series Model No. Port size

Reduced
Individual
Eff. X-sectional
0 1 2 3

wiring
wiring
area (mm2)
M3
Pilot operated 3-port valve ● MN3E00 φ1.8, φ3, φ4
MN3E Series
M5
● ● MN3E0 φ1.8, φ4, φ6 Push-in fitting
Two 3-port valves M5
● ● integrated MN3E0 φ1.8, φ4, φ6 Push-in fitting

M5
Pilot operated 3-port ● 3KA1
φ4, φ6 Push-in fitting
pneumatic valve M5
4K Series ● M3KA1
φ4, φ6 Push-in fitting
MN3S0 M5
Pilot operated 3-port ● ● MT3S0 φ4, φ6 Push-in fitting
pneumatic valve Two 3-port M5
MN4S0 Series valves integrated
● ● MN3SO φ4, φ6 Push-in
MT3SO fitting

M5
Pilot operated 3-port valve ● 3G A 1
D φ1.8, φ4, φ6 Push-in fitting
4G Series
Rc1/8,1/8NPT,G1/8
● 3G A 2
D φ4, φ6, φ8 Push-in fitting
Rc1/4, 1/4NPT, G1/4
● 3G A 3
3-port

D φ6, φ8, φ10 Push-in fitting


M5
● ● M3G A
D
1
φ1.8, φ4, φ6 Push-in fitting
Rc1/8, 1/8NPT, G1/8
● ● M3G A
D
2
φ4, φ6, φ8 Push-in fitting
Rc1/4, 1/4NPT, G1/4
● ● M3G A
D
3
φ6, φ8, φ10 Push-in fitting
M5
● ● MN3G A
D
1
φ1.8, φ4, φ6 Push-in fitting
Rc1/8, 1/8NPT, G1/8
● ● MN3G A
D
2
φ4, φ6, φ8 Push-in fitting

Pilot operated 3-port valve Rc1/8


W4G2 Series ● MW3GA2 φ4, φ6, φ8
Push-in fitting

Poppet type 3-port valve


PCD Series ● PCD Rc1/4 to Rc1/2

NP13
Large flow rate 3-port valve NP14
NP Series ● NAP11
Rc3/8 to Rc2
NVP11

Intro 19
Search method 1 2 3 4

Search
2-port 3-port 4, 5-port Related products

*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.

0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160

763

1231

1165

221

863

1743

660
1623

Intro 20
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.

Wiring method Flow


Manifold Model
characteristics 0 0.2 0.4 0.6
Port

C [dm3/(bar)]

Single unit
Series Port size
No. Eff. X-sectional

Reduced
Individual
0 1 2 3

wiring
wiring
area (mm2)
Pilot operated 5-port ● W2P513* M5
miniature pneumatic valve
P514* ● P5142 _
B514*
● B5142 M5
W2P513*
B*P514* M5
● B*P5142
Rc1/8
N*P514*
● N*P5142 φ4 Push-in fitting

Pilot operated 5-port small M3


pneumatic valve ● 4SA0
4S0 Series φ4 Barbed fitting

● 4SB0 M5

M3
● M4SA0
φ4 Barbed fitting

M5
● ● M4SB0 φ4 Push-in fitting
φ4, φ6 Barbed fitting

Pilot operated 4-port valve M3


● MN4E00 φ1.8, φ3, φ4
MN4E Series
M5
● ● MN4E0 φ1.8, φ4, φ6 Push-in fitting
Pilot operated 4-port ● ● MN4S0 M5
pneumatic valve
4, 5-port valve

φ4, φ6 Push-in
MN4S0 Series ● ● MT4S0 fitting

M5
Pilot operated 5-port valve ● 4G A 1
D φ1.8, φ4, φ6 Push-in fitting
4G Series
Rc1/8, 1/8NPT, G1/8
● 4G A 2
D φ4, φ6, φ8 Push-in fitting
Rc1/4, 1/4NPT, G1/4
● 4G A 3
D φ6, φ8, φ10 Push-in fitting
Rc3/8, 3/8NPT, G3/8
● 4G A 4
D φ8, φ10, φ12 Push-in fitting
A M5
● ● M4G D1 φ1.8, φ4, φ6 Push-in fitting
A Rc1/8, 1/8NPT, G1/8
● ● M4G D2 φ4, φ6, φ8 Push-in fitting
A Rc1/4, 1/4NPT, G1/4
● ● M4G D3 φ6, φ8, φ10 Push-in fitting
Rc3/8, 3/8NPT, G3/8
● ● M4GA4 φ8, φ10, φ12 Push-in fitting
Rc1/8, 1/8NPT,
● 4G B 1
E G1/8
Rc1/4, 1/4NPT,
● 4G B 2
E G1/4
Rc1/4, 1/4NPT, G1/4
● 4G B 3
E Rc3/8, 3/8NPT, G3/8
Rc3/8, 3/8NPT, G3/8
● ● 4GB4 Rc1/2, 1/2NPT, G1/2
M5
● ● M4G B
E
1
φ1.8, φ4, φ6 Push-in fitting
Rc1/8, 1/8NPT, G1/8
● ● M4G B
E
2
φ4, φ6, φ8 Push-in fitting
Rc1/4, 1/4NPT, G1/4
● ● M4G B
E
3
φ6, φ8, φ10 Push-in fitting
1/4(RC, NPT, G),
3/8(RC, NPT, G),
● ● M4GB4 1/2(RC, NPT, G)
φ8, φ10, φ12 push-in fitting

Intro 21
Search method 1 2 3 4

Search
2-port 3-port 4, 5-port Related products

*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.

0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160

1583

1205

763

1165

Intro 22
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.

Wiring method Flow


Manifold
characteristics 0 0.2 0.4 0.6
C [dm3/(bar)]

Single unit
Port

Series Model No. Port size

Reduced
Individual
Eff. X-sectional
0 1 2 3

wiring

wiring
area (mm2)
M5
Pilot operated 5-port valve ● ● MN4G A
D
1
φ4, φ6 Push-in fitting
4G Series
Rc1/8, 1/8NPT, G1/8
● ● MN4G A
D
2
φ4, φ6, φ8 Push-in fitting
φ4, φ6 Push-in
● ● MN4G B
E
1
fitting
φ4, φ6, φ8
● ● MN4G B
E
2
Push-in fitting

● W4GB2 Rc1/4
Pilot operated 5-port valve
W4G2 Series Rc1/8
● ● MW4GA2 φ4, φ6, φ8 Push-in fitting
φ4, φ6, φ8
● ● MW4GB2 Push-in fitting
φ4, φ6, φ8
● ● MW4GZ2 Push-in fitting

● W4GB4 Rc1/4, Rc3/8 *3


Pilot operated 5-port valve
W4G4 Series
● W4GZ4 Rc1/4, Rc3/8 *3

Rc1/4, Rc3/8
● ● MW4GB4 φ8, φ10, φ12 push-in *3
M5
● 4KA1
Pilot operated 5-port φ4, φ6 Push-in fitting
pneumatic valve Rc1/8
● 4KA2
φ6, φ8 Push-in fitting
4K Series
4 , 5 -port valve

Rc1/4
● 4KA3
φ8, φ10 Push-in fitting
Rc3/8
● 4KA4
φ10, φ12 Push-in fitting
M5
● M4KA1
φ4, φ6 Push-in fitting
Rc1/8
● M4KA2
φ6, φ8 Push-in fitting
Rc1/4
● M4KA3
φ8, φ10 Push-in fitting
Rc3/8
● M4KA4
φ10, φ12 Push-in fitting

● 4KB1 Rc1/8

● 4KB2 Rc1/8, Rc1/4

● 4KB3 Rc1/4, Rc3/8

● 4KB4 Rc3/8, Rc1/2

M5, Rc1/8
● M4KB1
φ6 Push-in fitting
Rc1/8, Rc1/4
● M4KB2
φ6, φ8 Push-in fitting
Rc1/4, Rc3/8
● M4KB3
φ8, φ10 Push-in fitting
Rc3/8, Rc1/2
● M4KB4
φ10, φ12 Push-in fitting
φ4, φ6, φ8
● MN4KB1
Push-in fitting
φ6, φ8, φ10
● MN4KB2
Push-in fitting

Intro 23
Search method 1 2 3 4

Search
2-port 3-port 4, 5-port Related products

*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.
*3: G threads and NPT threads are also compatible.

0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160

221

863

1003

1231

Intro 24
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.

Wiring method Flow


Manifold
characteristics
C [dm3/(bar)]
0 0.2 0.4 0.6

Single unit
Port

Series Model No. Port size

Individual

Reduced
Eff. X-sectional
0 1 2 3

wiring

wiring
area (mm2)

Pilot operated 4, 5-port valve ● MN4TB1 φ4, φ6, φ8 Push-in fitting


4T Series
(Plug-in type) ● MN4TB2 φ6, φ8, φ10 Push-in fitting

● 4TB3 Rc1/4, Rc3/8

● 4TB4 Rc3/8, Rc1/2

● M4TB3 Rc1/4, Rc3/8

● M4TB4 Rc3/8, Rc1/2

Pilot operated 5-port ● 4F0 M5, Rp1/8


pneumatic valve
4F Series ● 4F1 Rp1/8, Rp1/4

● 4F2 Rp1/4

● 4F3 Rp1/4, Rp3/8

● 4F4 Rc1/4, Rc3/8

● 4F5 Rc3/8, Rc1/2

● 4F6 Rc1/2, Rc3/4


4 , 5 -port valve

● 4F7 Rc3/4, Rc1

● M4F0 M5, Rp1/8

● M4F1 Rp1/8, Rp1/4

● M4F2 Rp1/4

Rp1/4
● M4F3
Rp3/8

● M4F4 Rc1/4

● M4F5 Rc3/8

● M4F6 Rc1/2

● M4F7 Rc3/4

Pilot operated 5-port ● 4L2-4 Rc1/4


pneumatic valve
4L2-4/LMFO Series Rc1/8, Rc1/4
(Plug-in type) ● LMF0 φ4, φ6 Push-in fitting

Pilot operated 5-port ● PV5G-6, PV5-6 Rc1/4, Rc3/8

ISO valve
● PV5G-8, PV5-8 Rc3/8 to Rc3/4
PV5G/
PV5/ ● GMF1 Rc1/4, Rc3/8
GMF
Series ● GMF2 Rc3/8, Rc1/2

Intro 25
Search method 1 2 3 4

Search
2-port 3-port 4, 5-port Related products

*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.

0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160

1079

1337

1147

1431

Intro 26
3 Search by flow characteristics C
Ideal model with flow characteristics C can be selected.

Wiring method Flow


Manifold
characteristics
C [dm3/(bar)]
0 0.2 0.4 0.6

Single unit
Port

Series Model No. Port size

Individual

Reduced
Eff. X-sectional
0 1 2 3

wiring

wiring
area (mm2)

Explosion proof 5-port ● 4F3*0EX Rp1/4, Rp3/8

pneumatic valve ● 4F4*0EX Rc1/4, Rc2/8


4F**0EX Series
● 4F5*0EX Rc3/8, Rc1/2

● 4F6*0EX Rc1/2, Rc3/4

● 4F7*0EX Rc3/4, Rc1

● M4F3*0EX Rp1/4, Rp3/8

● M4F4*0EX Rc1/4

● M4F5*0EX Rc3/8

● M4F6*0EX Rc1/2

● M4F7*0EX Rc3/4
4 , 5 -port valve

Explosion proof 5-port ● 4F3*0E Rp1/4, Rp3/8

pneumatic valve ● 4F4*0E Rc1/4, Rc2/8


4F**0E Series
● 4F5*0E Rc3/8, Rc1/2

● 4F6*0E Rc1/2, Rc3/4

● 4F7*0E Rc3/4, Rc1

● M4F3*0E Rp1/4, Rp3/8

● M4F4*0E Rc1/4

● M4F5*0E Rc3/8

● M4F6*0E Rc1/2

● M4F7*0E Rc3/4

Pilot operated 4-port valve Rc1/4, Rc3/8,


● PCD
Rc1/2
PCD Series

Manual override switching ● HMV Rc1/4


4-port valve
HMV/HSV Series ● HSV Rc1/4 to Rc3/4

Shock absorbing valve ●


2 
SKH3 3 5 0 Rc3/8 / Rc1/2
SKH Series

2 
SKH4 3 5 0 Rc3/8 / Rc1/2
Related products


2 
SKH5 3 5 0 Rc3/8 / Rc1/2

Rc1/4 / Rc3/8 /

2 
SKH3 3 5 8
Rc1/2
Rc1/4 / Rc3/8 /

2 
SKH4 3 5 8
Rc1/2
Rc1/4 / Rc3/8 /
● SKH318
Rc1/2
Rc1/4 / Rc3/8 /
● SKH418
Rc1/2

Intro 27
Search method 1 2 3 4

Search
2-port 3-port 4, 5-port Related products

*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: The port sizes listed are representative examples.

0.8 1.0 1.2 1.4 2.0 4.0 6.0 8.0 10.0 12.0 16.0 20.0 32.0
Page
4 5 6 7 10 20 30 40 50 60 80 100 160

1655

1679

1743

1705

1723

Intro 28
4 Search by specifications and variation

Individual wiring manifold


Flow characteristic C Effective cross-sectional area
Series name Manifold model No. [dm3/(s·bar)] (mm2) Remarks Page
4, 5-port valve
One-sided
MN4E0 Series MN4E0 0.5 to 0.54 - 796
solenoid type
4S0 Series M4SA0 - 0.9
1218
(small pneumatic valve) M4SB0 0.29 to 0.32 -
M4G DA 96/410
0.70 to 8.0
M4G BE 112/422
4G Series -
MN4G DA 226/516
0.71 to 2.3
MN4G BE 234/524
MW4GA2 One-sided 874
W4G2 Series MW4GB2 1.7 to 2.3 - solenoid/ 878
MW4GZ2 plug-in type 878
Pilot operated
W4G4 Series MW4GB4 6.4 to 7.4 - Plug-in type 1010
soft spool valve
MN4S0 Series MN4S0 One-sided
0.57 to 0.80 - 1170
(pneumatic valve) MT4S0 solenoid type
M4KA 1272
4K Series
M4KB 0.60 to 11 - 1284
(pneumatic valve)
MN4KB 1304
(A)M4F0
1376
4F Series M4F1 to M4F3 160
0.6 to 18
(pneumatic valve) M4F4 to 7 (4F7) 1404
M4F**E Explosion-proof 1694
PV5G/PV5/CMF Series GMF1 1450
2.8 to 11.6 -
(ISO valve) GMF2 1454
2, 3-port valve
MN3E0 Series MN3E0 0.54 - One-sided 796

M3GA 0.70 to 2.5 96


3G Series -
Pilot operated MN3GA 0.71 to 1.7 226
soft spool valve MN3S0 Series MN3S0 One-sided
0.80 - 1170
(pneumatic valve) MT3S0 solenoid type
3K Series M3KA
0.69 - 1272
(pneumatic valve)
3M Series M3MA0
- 0.1 to 0.5 1546
(small pneumatic valve) M3MB0
Direct acting poppet M3QRA
3QR Series 0.30 to 0.40 - 1528
valve M3QRB
3P Series M3PA
0.31 to 1.1 - 1570
(pneumatic valve) M3PB
Pilot operated P/M/B Series B*P51 1588
0.09 to 0.15 -
poppet valve (Miniature pneumatic valve) N*P512/3/4 1610
Two 3-port valves integrated
MN3E0 Series MN3E0 0.5 - One-sided 796

M3G DA 96/410
Pilot operated M3G BE 112/422
3G Series 0.66 to 1.7 -
soft spool valve MN3G DA 226/516
MN3G BE 234/524
MN3S0 Series MN3S0 One-sided
0.50 - 1170
(pneumatic valve) MT3S0 solenoid type
Note: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 x C.

Intro 29
Search method 1 2 3 4

Search
Individual wiring manifolds, reduced wiring manifolds, reduced wiring slave units, reduced wiring blocks, copper and PTFE free,
ozone-proof specifications, rechargeable batteries, clean-room specifications, coolant proof products, manual switching valves

Reduced wiring manifolds


Flow characteristic C
Series name Manifold model No. [dm3/(s·bar)] Remarks Page
4, 5-port valve
MN4E00 0.32 One-sided 772
MN4E Series
MN4E0 0.50 to 0.54 solenoid type 796
4S0 Series
M4SB0 0.29 to 0.32 1222
(small pneumatic valve)
M4G DA 136/436
0.70 to 8.0
M4G BE 153/456
4G Series
MN4G DA 242/532
0.71 to 2.3
MN4G BE 258/548
MW4GA2 One-sided 884
W4G2 Series MW4GB2 1.7 to 2.3 solenoid/ 906
Pilot operated plug-in type
MW4GZ2 906
soft spool valve
Plug-in
W4G4 Series MW4GB4 6.4 to 7.4 1020
type
MN4S0 Series MN4S0 One-sided
0.57 to 0.80 1170
(pneumatic valve) MT4S0 solenoid type
MN4TB1 0.51 to 1.6
One-sided 1100
MN4TB2 2.1 to 2.8
4TB Series solenoid/
M4TB3 4.9 to 8.8
plug-in type 1084
M4TB4 9.6 to 13.8
4L2-4/LMF0 Series Plug-in
LMF0 1.8 to 2.9 1150
(pneumatic valve) type
3-port valve
MN3E00 0.32 One-sided 772
MN3E Series
MN3E0 0.54 solenoid type 796
M3G DA 0.70 to 2.5 136/436
3G Series
Pilot operated MN3G DA 0.71 to 1.7 242/532
soft spool valve One-sided
W3G2 Series MW3GA2 1.7 884
solenoid type
MN3S0 Series MN3S0 One-sided
0.80 1170
(pneumatic valve) MT3S0 solenoid type
Two 3-port valves integrated
MN3E00 0.32 One-sided 772
MN3E Series
MN3E0 0.50 solenoid type 796
M3G DA 136/436
Pilot operated M3G BE 153/456
3G Series 0.66 to 1.7
soft spool valve MN3G DA 242/532
MN3G BE 250/548
MN3S0 Series MN3S0 One-sided
0.50 1170
(pneumatic valve) MT3S0 solenoid type
Note: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 x C.

Intro 30
4 Search by specifications and variation

Reduced wiring slave unit


PLC manufacturer Communication system Wiring block model No. Slave unit series Incorporated valve
T6G1 OPP2 Series MW4G4, MN4TB, M4TB, LMF0
T6G1 OPP3 Series MN4S0, MN4E, MN4G, M4G
CC-Link Partner T7G1 OPP4 Series MN4G
Association CC-Link
T8G1/2/7 OPP5 Series MW4G2
Mitsubishi Electric (ver1.10)
Corporation T7G1/2 OPP6 Series MN4E
T8G1/2
OPP7 Series M4G, MN4G
T8GP1/2
T6D1 OPP2 Series MW4G4, MN4TB, M4TB, LMF0
ODVA T7D1 OPP4 Series MN4G
DeviceNet
OMRON Corporation T8D1/2/7 OPP5 Series MW4G2
T7D1/2 OPP6 Series MN4E
T6C0/1 OPP2 Series MW4G4, MN4TB, M4TB, LMF0
T6C0/1 OPP3 Series MN4S0, MN4E, MN4G, M4G
OMRON Corporation CompoBus/S
T7C0/1 OPP4 Series MN4G
T8C1/6 OPP5 Series MW4G2
Japan Profibus Association T8P1/2
PROFIBUS-DP OPP7 Series M4G, MN4G
SIEMENS Corporation T8PP1/2
T8EC1/2
OPP7 Series M4G, MN4G
OMRON Corporation T8ECP1/2
EtherCAT
Beckhoff Automation T7EC1/2
OPP8 Series MW4G
T7ECP1/2
T8EN1/2
ODVA TAG JAPAN EtherNet/IP OPP7 Series M4G, MN4G
T8ENP1/2
OPP2 Series MW4G4, MN4TB, M4TB, LMF0
CKD UNIWIRE SYSTEM T6A0/1
OPP3 Series MN4S0, MN4E, MN4G, M4G
KURODA Pneumatics
Ltd. UNIWIRE H OPP2 Series MW4G4, MN4TB, M4TB, LMF0
T6J0/1
SYSTEM OPP3 Series MN4S0, MN4E, MN4G, M4G
T6E0/1 OPP3 Series MN4S0, MN4E, MN4G, M4G
S-LINK
SUNX T7E0/1 OPP4 Series MN4G
S-LINK V T7N1/2 OPP6 Series MN4E
Ontec SAVENET T7L1 OPP4 Series MN4G
Japan AS-i Association AS-i T8MA/6 OPP5 Series MW4G2
● Contact CKD for information on compatibility with other networks.
*1 When making arrangements for a reduced wiring manifold, the wiring block model No. will be displayed in the following manner.
(Example) MN4GA210- Port size - T7D1 Option - Station No. - Voltage

M: Manifold Wiring block model No.


MN: Block manifold
*2 The shape of the slave unit is as follows.
OPP2 Degree of protection (IP65) OPP3 Flat cable compatible slave unit OPP5 Degree of protection (IP65), connector connections
OPP4 Thin shape OPP6 Miniature 32 point compatible

Intro 31
Search method 1 2 3 4

Search
Individual wiring manifolds, reduced wiring manifolds, reduced wiring slave units, reduced wiring blocks, copper and PTFE free,
ozone-proof specifications, rechargeable batteries, clean-room specifications, coolant proof products, manual switching valves

Reduced wiring
slave unit
(serial transmission)

Serial transmission (OPP4) Serial transmission (OPP3) Serial transmission (OPP2)


● Thin slave unit ● The valve and slave unit can be ● A protective structure equivalent
● Easily connected/detached easily connected with connectors. to IP65 rating has been prepared.
with the slot-in system. ● Low-profile slave unit with ● It is possible to identify valve
height kept low. (At assembly) operations with the slave unit display.

Serial transmission (OPP5) Serial transmission (OPP6) Serial transmission (OPP7)


● Dust-proof/jet-proof protective ● Compact close contact type ● Thin slave unit
structure (IP65). ● Low-profile slave unit with height ● Easily connected/detached
● Power supply wires and communication wires kept the lowest in the series, with the slot-in system.
can be easily connected with connectors. compatible with up to 32 points.

Serial transmission (OPP8)


● High speed EtherCAT
communication supported
● A protective structure equivalent
to IP65 rating has been
prepared.

Intro 32
4 Search by specifications and variation

Reduced wiring block


Incorporated
Wiring method Wiring block model No. Incorporated valve model No. Remarks
valve Page
D sub-connector T30/R (24-pin) MN4E 763
T50/R (with power supply terminal 16 points) MN4G, M4G *1) ‌MW4G2 is not compatible with 1
MW4G2 (*1) T50 and T52. 863
T51/R (18-pin)
*2) M‌ N4SO and MN4TB are
Flat cable connector T52/R (8-pin) MN4SO (*2) not compatible with T51 1165
T53/R (24-pin) MN4TB (*2) and T52. 1079
T50A (16-pin) MN4TB Amplification circuit embedded 1079
Multi-connector T20 (16-pin) MW4G2 863
MN4G, M4G 1
MW4G2 (*2) 863
MW4G4 (*2) *2) ‌MW4G2, MW4G4, MN4TB,
T10/R (M3 screw system) 1003
Common terminal and M4TB are not
T11/R (clamping system) MN4SO compatible with T11. 1165
MN4TB (*2) 1079
M4TB (*2) 1079
TM1A (10-pin)
TM**: RITS connector
Intermediate wiring block TM1C (5-pin) MN4E 763
TM52: Flat cable connector
TM52 (8-pin)

Reduced 固
定 固定

wiring block
確 時リ 確認時リ

後 テナ 後1テナ

. は  .4は 

N 方向 N・方向

m に寄 mでに寄

ね せレ ねじせレ

固 ール 固定ール

し に爪 してに爪

下 掛け 下さ掛け

い い。

D sub-connector (T3*) Flat cable connector (T5*) Common terminal block (T1*)
● Quick connections using cables ● Quick connections using cables ● Valve wiring only requires
with connectors with connectors signal wires and a single
● Processing of relay terminal ● Processing of relay terminal block common wire
block and common wiring is and common wiring is not required ● A relay terminal block is not
not required ● An amplification circuit required
embedded is also available

Intermediate wiring block (TM*)


● Reduced wiring connection to
the center of the manifold is
possible.
● 10P flat cable connector and 6P
RITS connectors are available.
● No more trouble with
insufficient control points.

Intro 33
Search method 1 2 3 4

Search
Individual wiring manifolds, reduced wiring manifolds, reduced wiring slave units, reduced wiring blocks, copper and PTFE free,
ozone-proof specifications, rechargeable batteries, clean-room specifications, coolant proof products, manual switching valves

Copper and PTFE free Copper-based materials are not used.

Flow characteristics C Effective cross-sectional area


Series name Variation model No. [dm3/(s·bar)] (mm2) Remarks Page
4, 5-port valve
W2P513*-*-P6 0.12 to 0.15
P/M/B Series P5142-*-P6 0.09
Pilot operated
(Miniature pneumatic B5142-*-P6 0.09 - 1583
poppet valve
valve) B*P5142-*-P6 0.09
N*P5142-*-P6 0.09
4TB3*-*-P6 4.9 to 7.8 One-sided solenoid/
4TB4*-*-P6 9.8 to 14.6 plug-in type
M4TB3*-*-P6 4.9 to 8.8 Note) 4‌ T3 and 4T4
4TB Series - are standard 1079
M4TB4*-*-P6 9.6 to 13.8 specifications
with DC.
MN4TB1*-*-P6 0.51 to 1.6 (Model P6 will
MN4TB2*-*-P6 2.1 to 2.8 not be required.)
Pilot operated
4KA*-*-P6 0.60 to 11
soft spool valve
4KB*-*-P6 063 to 13
4K Series
M4KA*-*-P6 0.69 to 11 - 1231
(pneumatic valve)
M4KB*-*-P6 0.60 to 9.4
MN4KB*-*-P6 0.60 to 3.1
4F Series 4F*-*-P6 (M)4F0 is not
1.5 to 18 160(4F7) 1337
(pneumatic valve) M4F*-*-P6 supported.
Shock absorbing valve SKH*-*-P6 4.1 to 16.3 - 1723
2, 3-port valve
Pilot operated 3K Series 3KA1*-*-P6 0.65
- 1231
soft spool valve (pneumatic valve) M3KA1*-*-P6 0.69
P512/3*-*-P6 0.1
P/M/B Series M512/3*-*-P6 0.1
Pilot operated
(Miniature pneumatic B512/3*-*-P6 0.1 - 1583
poppet valve
valve) B*P512/3*-*-P6 0.11 to 0.15
N*P512/3-*-P6 0.11 to 0.15
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 x C.
*2: Other series are compatible as well. Contact CKD separately.

Intro 34
4 Search by specifications and variation

Main rubber parts used are ozone proof items

Ozone-proof specification product


Flow characteristics C Effective cross-sectional area
Series name Variation model No. [dm3/(s·bar)] (mm2) Remarks Page
4, 5-port valve
MN4E0 Series MN4E0*-*-A-* 0.50 to 0.54 - One-sided solenoid type 763
4SA0*-*-P11 - 0.90
4S0 Series 4SB0*-*-P11 0.29 to 0.33 -
1205
(small pneumatic valve) M4SA0*-*-P11 - 0.90
M4SB0*-*-P11 0.29 to 0.32 -
4G DA *-*-A-* 0.70 to 8.0
4G BE *-*-A-* 1.1 to 11
M4G DA *-*-A-* 0.70 to 8.0
4G Series - 1
M4G BE *-*-A-* 0.70 to 8.3
MN4G DA *-*-A-* 0.71 to 2.3
MN4G BE *-*-A-* 0.71 to 2.2
W4GB2*-*-A-* 2.1 to 2.5
Pilot operated One-sided
MW4GA2*-*-A-* 1.7 to 2.3
soft spool valve W4G2 Series - solenoid 863
MW4GB2*-*-A-* 1.7 to 2.3
type
MW4GZ2*-*-A-* 1.7 to 2.3
W4GB4*-*-A-*
6.4 to 7.3
W4G4 Series W4GZ4*-*-A-* - 1003
MW4GB4*-*-A-* 6.4 to 7.4
MN4S0 Series MN4S0*-*-P11 One-sided
0.57 to 0.80 - 1165
(pneumatic valve) MT4S0*-*-P11 solenoid type
4KA*-*-P11 0.60 to 11
4KB*-*-P11 0.63 to 13
4K Series
M4KA*-*-P11 0.69 to 11 - 1231
(pneumatic valve)
M4KB*-*-P11 0.60 to 9.4
MN4KB*-*-P11 0.60 to 3.1
● Ozone-proof components are available as a custom order. (However, the MN4E0 series, 4G series, W4G2 series, and W4G4 series are available as options.)
Note: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 x C.

Intro 35
Search method 1 2 3 4

Search
Individual wiring manifolds, reduced wiring manifolds, reduced wiring slave units, reduced wiring blocks, copper and PTFE free,
ozone-proof specifications, rechargeable batteries, clean-room specifications, coolant proof products, manual switching valves

Main rubber parts used are ozone proof items

Ozone-proof specification product


Flow characteristics C Effective cross-sectional area
Series name Variation model No. [dm3/(s·bar)] (mm2) Remarks Page
3-port valve
MN3E0 Series MN3E0*-*-A-* 0.54 One-sided solenoid type 763
3G DA *-*-A-* 0.70 to 3.9
3G Series M3G DA *-*-A-* 0.66 to 3.3 - 1
MN3G DA *-*-A-* 0.68 to 2.3
Pilot operated
W3G2 Series MW3GA2*-*-A-* 1.7 to 2.3 - One-sided solenoid type 863
soft spool valve
MN3S0 Series MN3S0-*-*-P11 One-sided
0.80 - 1165
(pneumatic valve) MT3S0-*-*-P11 solenoid type

3K Series 3KA*-*-P11 0.65


- 1231
(pneumatic valve) M3KA*-*-P11 0.69
3MA0*-*-P11
3M Series 3MB0*-*-P11
- 0.1 to 0.15 1541
(small pneumatic valve) M3MA0*-*-P11
Direct acting poppet M3MB0*-*-P11
valve 3PA*-*-P11 0.34 to 1.1
3P Series 3PB*-*-P11 0.33 to 1.0
- 1557
(pneumatic valve) M3PA*-*-P11 0.37 to 1.1
M3PB*-*-P11 0.32 to 0.93
Two 3-port valves integrated
MN3E0 Series MN3E0*-*-A-* 0.50 - One-sided solenoid type 763
3G DA *-*-A-* 0.66 to 1.8
3G BE *-*-A-* 0.92 to 1.7
Pilot operated
M3G DA *-*-A-* 0.66 to 1.7
soft spool valve 3G Series - 1
M3G BE *-*-A-* 0.67 to 1.6
MN3G DA *-*-A-* 0.68 to 1.6
MN3G BE *-*-A-* 0.66 to 1.6
● Ozone-proof components are available as a custom order. (However, the MN4E0 series, 4G series, and W4G2 series are available as options.)
Note: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 x C.

Intro 36
4 Search by specifications and variation

Pneumatic components exclusively for materials which can


Specifications for rechargeable battery be used in the rechargeable battery manufacturing process.
Flow characteristics C
Series name Variation model No. [dm3/(s·bar)] Remarks Page
4, 5-port valve
4G DA *-*-P4 0.66 to 4.0
4G BE *-*-P4 1.0 to 4.2
M4G DA *-*-P4 0.66 to 3.3 CC-
4G Series
M4G BE *-*-P4 0.67 to 3.3 1226A
MN4G DA *-*-P4 0.68 to 2.3
MN4G BE *-*-P4 0.66 to 2.2
Pilot operated
W4GB2*-*-P40 2.1 to 2.5
soft spool valve One-sided
MW4GA2*-*-P40 1.7 to 2.3 CC-
W4G2 Series solenoid
MW4GB2*-*-P40 1.7 to 2.3 plug-in type 1226A
MW4GZ2*-*-P40 1.7 to 2.3
W4GB4*-*-P40 6.4 to 7.7
CC-
W4G4 Series MW4GB4*-*-P40 6.4 to 8.3 Plug-in type
1226A
MW4GZ4*-*-P40 6.4 to 8.3
3-port valve
3G DA *-*-P4 0.70 to 3.9
Pilot operated 3G Series M3G DA *-*-P4 0.66 to 3.3 CC-
soft spool valve MN3G DA *-*-P4 0.68 to 2.3 1226A
W3G2 Series MW3GAZ*-*-P40 1.7 One-sided solenoid type
Two 3-port valves integrated
3G DA *-*-P4 0.66 to 2.2
3G BE *-*-P4 1.0 to 2.1
Pilot operated M3G DA *-*-P4 0.66 to 1.7 CC-
3G Series
soft spool valve M3G BE *-*-P4 0.67 to 1.6 1226A
MN3G DA *-*-P4 0.68 to 1.6
MN3G BE *-*-P4 0.66 to 1.6
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: Refer to Catalog No. CC-947 “Components for rechargeable battery production P4* Series”.

Anti-dust generation pneumatic


Clean-room specifications components usable in clean rooms.
Flow characteristics C
Series name Variation model No. [dm3/(s·bar)] Remarks Page
4, 5-port valve
MN4E Series MN4E*-*-P70 0.30 to 0.54 One-sided solenoid type 763
4G DA *-*-P7* 0.66 to 4.0
Pilot operated
M4G DA *-*-P7* 0.66 to 3.3
soft spool valve 4G Series 1
4G BE *-*-P7* 1.0 to 4.2
M4G BE *-*-P7* 0.67 to 3.3
3-port valve
MN3E Series MN3E*-*-P70 0.30 to 0.54 One-sided solenoid type 763
Pilot operated
3G DA *-*-P7* 0.70 to 3.9
soft spool valve 3G Series 1
M3G DA *-*-P7* 0.66 to 3.3
Two 3-port valves integrated
MN3E Series MN3E*-*-P70 0.30 to ,0.50 One-sided solenoid type 763
3G DA *-*-P7* 0.66 to 2.2
3G BE *-*-P7* 1.0 to 2.1
Pilot operated
M3G DA *-*-P7* 0.66 to 1.7
soft spool valve 3G Series 1
M3G BE *-*-P7* 0.67 to 1.6
MN3G DA *-*-P7* 0.68 to 1.6
MN3G BE *-*-P7* 0.66 to 1.6
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C.
*2: Refer to Catalog No. CB-033SA “Pneumatic components for clean room specifications.”
Intro 37
Search method 1 2 3 4

Search
Individual wiring manifolds, reduced wiring manifolds, reduced wiring slave units, reduced wiring blocks, copper and PTFE free,
ozone-proof specifications, rechargeable batteries, clean-room specifications, coolant proof products, manual switching valves

Pneumatic components using valve materials


Coolant proof product with excellent oil resistance and water resistance.
Flow characteristics C
Series name Variation model No. [dm3/(s·bar)] Remarks Page
4, 5-port valve
4G DA *-*-A-* 0.70 to 8.0
4G BE *-*-A-* 1.1 to 11
M4G DA *-*-A-* 0.70 to 8.0
4G Series 1
M4G BE *-*-A-* 0.70 to 8.3
MN4G DA *-*-A-* 0.71 to 2.3
MN4G BE *-*-A-* 0.71 to 2.2
W4GB2*-*-A-* 2.1 to 2.5
MW4GA2*-*-A-* 1.7 to 2.3 One-sided
W4G2 Series solenoid/ 863
MW4GB2*-*-A-* 1.7 to 2.3 Plug-in type
Pilot operated MW4GZ2*-*-A-* 1.7 to 2.3
soft spool valve W4GB4*-*-A-* 6.4 to 7.3
W4G4 Series Plug-in type 1003
MW4GB4*-*-A-* 6.4 to 7.4
MN4TB1*-*-A-* 0.51 to 1.6 *2
MN4TB2*-*-A-* 2.1 to 2.8 One-sided CC-N-375A
4TB Series solenoid/
M4TB3*-*-A-* 4.9 to 8.8 Plug-in type Guide to
M4TB4*-*-A-* 9.6 to 13.8 pneumatic
devices
4K Series 4KA*-*-A 0.60 to 11 compatible
(pneumatic valve) 4KB*-*-A 0.63 to 13 with cutting oil
PV5G/PV5 Series PV5G-*-*-*-A-*
2.8 to 6.9 1431
(ISO valve) PV5-*-*-A-*-TC
3-port valve
3G DA *-*-A-* 0.70 to 3.9
3G Series M3G DA *-*-A-* 0.66 to 3.3 1
MN3G DA *-*-A-* 0.68 to 2.3
Pilot operated
W3G2 Series MW3GA2*-*-A-* 1.7 One-sided solenoid type 863
soft spool valve *2
3K Series CC-N-375A
3KA1*-*-A 0.65 Guide to pneumatic
(pneumatic valve) devices compatible
with cutting oil
Two 3-port valves integrated
3G DA *-*-A-* 0.66 to 1.8
3G BE *-*-A-* 0.92 to 1.7
Pilot operated M3G DA *-*-A-* 0.66 to 1.7
3G Series 1
soft spool valve M3G BE *-*-A-* 0.67 to 1.6
MN3G DA *-*-A-* 0.68 to 1.6
MN3G BE *-*-A-* 0.66 to 1.6
*1: Effective cross-sectional area S and sonic conductance C are converted as S ≈ 5.0 × C. *2: Refer to Catalog No. CC-N-375A “Guide to pneumatic devices compatible with coolants”.

Manual selector valve


Flow characteristic
Series name Model No. C[dm3/(s·bar)] Eff. X-sectional area (mm2) Remarks Page
4-port valve
Miniature HMV 1.5 to 1.6 -
1705
Standard HSV 7.2 to 10.3 -
3-port valve
Compact mechanical valve MS - 1.6 to 2.5 Detector
Medium mechanical valve MM - 1.6 to 2.5 total air 1767
Large mechanical valve MAVL - 31 system
Quick valve 3QV - - φ4 to φ12 1713
2-port valve
Quick valve 2QV - - φ4 to φ12 1713

Intro 38
SystemSystem
selectionselection
Even beginners can easily make a model selection.

How to make a system selection


An overview of the selection is available
with the following two conditions.

When selecting peripheral pneumatic components, having determined


cylinder bore size and operation speed

Operation speed Bore size

Workpiece

To Intro Page 40

When selecting peripheral pneumatic components, having determined bore


size from cylinder load and operating time

Load conditions Bore size


Operation time

Workpiece

To Intro Page 51

Intro 39
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time

Selection
Selecting from cylinder bore size and operation speed

Whether the cylinder bore size and cylinder


[Confirming conditions] being used are driven with relative high or low
speed is determined as a condition.
Check cylinder tube bore size
and cylinder operation speed Using Table 1 as a reference, select the theoretical
reference speed of the cylinder.
Select the theoretical reference speed
(1) Bore size φ□
(2) Operation speed 
Low speed/medium speed/
From Table 1 high speed/ultra-high speed

Select appropriate fluid control components Refer to Table 2 and select appropriate fluid control
from bore size and theoretical reference components (valve, speed controller, silencer,
speed, and select [required flow rate] piping) and [required flow rate] for corresponding
cylinder bore size and theoretical reference speed.
From to Table 2

Refer to Table 3, and select a component with a


[max. flow rate] higher than the [Required flow rate]
Select the clean air system
value.
components When controlling multiple cylinders with a set of
clean air system components, select the clean air
From to Table 3 system component having a [max. flow rate] higher
than the [total of required flow rates].

* The relationship of the cylinder bore size and speed for the valve (4G Series/4K
Series) is shown in a graph.
"A combination of the valve and the cylinder's standard system" (Example) Intro
Pages 49 to 50

(1) The cylinder average speed is obtained from the combination of the valve and piping system. It is expressed as the cylinder's
piston speed calculated by dividing the stroke length by the time that the piston rod takes from start to end of movement with the
cylinder rod installed facing upward. When the load factor is 50%, the average speed should be approximately the cylinder's
piston speed multiplied by 0.5. (Refer to Intro Page 53 for the relation of load factor and theoretical reference speed. )
(2) The cylinder theoretical reference speed is the value of when one cylinder moves independently.
(3) The valve's effective cross-sectional area used in the calculation for Table 2 is the 2-position value.
(4) This selection guide is for reference. With the CKD sizing program, confirm conditions to be actually used.

Intro 40
System selection

STEP1 Conditions confirmation/theoretical reference speed selection


As a condition, it is predetermined whether bore size and cylinder are to be operated at a relatively high speed or at a
relatively low speed.

Table 1
Degree of
cylinder speed Low speed Medium speed High speed Ultra high speed
Theoretical reference
speed (mm/s)
250 500 750 1,000

STEP2 Fluid control components selection


Select appropriate fluid control components (valve, speed controller, silencer, piping) and [required flow rate] for bore size
and theoretical reference speed selected from Table 1.
Table 2
Theoretical reference Required composite
Required flow rate
Bore size (mm) speed (mm/s) effective cross-sectional area Valve
(ℓ/min) (ANR)
Note) (mm2) Single solenoid
MN4E010
φ6 500 5 0.1
4SA010/4SB010
MN4E010
φ10 500 14 0.2
4SA010/4SB010
MN4E010
φ16 500 36 0.5
4SA010/4SB010
4KA110/4KB110
250 29 0.5
4GA110R/4GB110R
500 56 0.9
φ20 4KA110/4KB110
750 84 1.4
4GA110R/4GB110R
1,000 112 1.8

250 44 0.8 4KA110/4KB110

500 88 1.4 4GA110R/4GB110R


φ25
750 132 2.1 4KB110/4GB110R

1,000 175 2.8 4KB210/4GB210R


4KA110/4KB110
250 73 1.3
4GA110R/4GB110R
500 143 2.9
φ32 4KA210/4KB210
750 215 3.5
4GA210R/4GB210R
1,000 286 4.6

Note) The above table indicates theoretical reference speed at cylinder bore size.
Refer to the individual specifications of each model for the working piston speed range.

Intro 41
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time

Selection
*1: Refer to Intro Page 57 for piping specifications.

Suitable control components


Pneumatic auxiliary components Piping *1
Double solenoid Speed controller Silencer Piping (between valve and cylinder)
MN4E020
SC3W-M5-4 SLM-M5,SLM-M3 φ4 x φ2.5 nylon tube
4SA020/4SB020
MN4E020
SC3W-M5-4 SLM-M5,SLM-M3 φ4 x φ2.5 nylon tube
4SA020/4SB020
MN4E020
SC3W-M5-4 SLM-M5,SLM-M3 φ4 x φ2.5 nylon tube
4SA020/4SB020
4KA120/4KB120 SC3W-6-6
SLM-M5,SLW-6A φ6 x φ4 nylon tube
4GA120R/4GB120R SCL2-06-H66

4KA120/4KB120 SC3W-6-6
SLM-M5,SLW-6A φ6 x φ4 nylon tube
4GA120R/4GB120R SCL2-06-H66

4KA120/4KB120 SC3W-6-6
SLM-M5,SLW-6A φ6 x φ4 nylon tube
4GA120R/4GB120R SCL2-06-H66

4KB120/4GB120R SC1-6 SLW-6A,SL-M5 φ8 x φ5.7 nylon tube

4KB220/4GB220R SCL2-08-H88 SLW-6S,SLW-6A φ8 x φ5.7 nylon tube


4KA120/4KB120 SC3W-6-6
SLM-M5,SLW-6A φ6 x φ4 nylon tube
4GA120R/4GB120R SCL2-06-H66

4KA220/4KB220 SC1-6
SLW-6S,SLW-6A φ8 x φ5.7 nylon tube
4GA220R/4GB220R SCL2-08-H88

Intro 42
System selection
Theoretical reference Required composite
Required flow rate
Bore size (mm) speed (mm/s) effective cross-sectional area Valve
(ℓ/min) (ANR)
Note) (mm2) Single solenoid
250 110 1.7
4KA210/4KB210
500 230 3.3
4GA210R/4GB210R
φ40
750 340 5.0

1,000 450 6.6

250 180 2.6


4KA210/4KB210
4GA210R/4GB210R
500 350 5.2
φ50
750 530 7.7 4GA310R/4GB310R
4GA310R/4GB310R
1,000 710 10.4
4F310/4F410
4KA210/4KB210
250 280 4.1
4GA310R/4GB310R
500 560 8.2 4GA310R/4GB310R
φ63
4KA310/4KB310
750 840 12.3
4F310/4F410
1,000 1,100 16.4 4F510

250 450 6.6 4KB210/4F210-08


4F410-10/4F310-10
500 910 13.2
4KB310-10
φ80
750 1,400 19.8
4KB410-15
4F510-15
1,000 1,800 26.4

4GA410-10/4GB410-10
250 710 10.3 4F410-10/4F310-10
4KB310-10

500 1,400 20.6


φ100 4GB410-15
4KB410-15/4F510-15
750 2,100 30.9

1,000 2,800 41.2 4F610-20

Note) The above table indicates theoretical reference speed at cylinder bore size.
Refer to the individual specifications of each model for the working piston speed range.

Intro 43
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time

Selection
*1: Refer to Intro Page 57 for piping specifications.

Suitable control components


Pneumatic auxiliary components Piping *1
Double solenoid Speed controller Silencer Piping (between valve and cylinder)
SC3W-6-6
SLM-M5,SLW-6A φ6 x φ4 nylon tube
SCL2-06-H66
4KA220/4KB220 SC1-6
SLW-6S,SLW-6A φ8 x φ5.7 nylon tube
4GA220R/4GB220R SCL2-08-H88
SC1-8 SLW-8A,SLW-6A φ10 x φ7.2 nylon tube

SC1-8 SLW-8A,SLW-8S φ10 x φ7.2 nylon tube


SC1-6
SLW-6A,SLW-6S φ8 x φ5.7 nylon tube
4KA220/4KB220 SCL2-08-H88
4GA220R/4GB220R
SC1-8 SLW-8A,SLW-6A φ10 x φ7.2 nylon tube

4GA320R/4GB320R SCL2-10-H1010 SLW-8A,SLW-8S φ10 x φ7.2 nylon tube


4GA320R/4GB320R φ15 x φ11.5 nylon tube or
SC1-10 SLW-10A
4F320/4F420 Rc3/8 steel pipe
4KA220/4KB220 SC1-6
SLW-6S,SLW-6A φ8 x φ5.7 nylon tube
4GA320R/4GB320R SCL2-08-H88
SC1-8
4GA320R/4GB320R SLW-8A,SLW-8S φ10 x φ7.2 nylon tube
SCL2-10-H1010
4KA320/4KB320 φ15 x φ11.5 nylon tube or
SC1-10 SLW-10A
4F320/4F420 Rc3/8 steel pipe
4F520 SC1-15 SLW-15A Rc1/2 steel pipe
SC1-8
4KB220/4F220-08 SLW-8A,SLW-8S φ10 x φ7.2 nylon tube
SCL2-10-H1010
4F420-10/4F320-10 φ15 x φ11.5 nylon tube or
SC1-10 SLW-10A
4KB320-10 Rc3/8 steel pipe
SC1-15 SLW-15A Rc1/2 steel pipe
4KB420-15
4F520-15
SC-20A SLW-15A Rc1/2 steel pipe

4GA420-10/4GB420-10
φ15 x φ11.5 nylon tube or
4F420-10/4F320-10 SC1-10 SLW-10A
Rc3/8 steel pipe
4KB320-10

SC1-15 SLW-15A Rc1/2 steel pipe


4GB420-15
4KB420-15/4F520-15
SC-20A SLW-15A Rc1/2 steel pipe

4F620-20 SC-20A SL-20A,SLW-20S Rc3/4 steel pipe

Intro 44
System selection
Theoretical reference Required composite
Required flow rate
Bore size (mm) speed (mm/s) effective cross-sectional area Valve
(ℓ/min) (ANR)
Note) (mm2) Single solenoid
250 1,100 16.1
4GB410-15
4KB410-15/4F510-15
500 2,200 32.2
φ125
750 3,300 48.2
4F610-20
1,000 4,400 64.4
4GB410-15
250 1,400 20.2
4KB410-15/4F510-15
500 2,800 40.4
φ140 4F610-20
750 4,200 60.5

1,000 5,500 80.8 4F710-25


4GB410-15
250 1,800 26.3
4KB410-15/4F510-15
500 3,600 52.6 4F610-20
φ160
750 5,400 79.0 4F710-20

1,000 7,200 104.7 -


4KB410-15
250 2,300 33.3
4F510-15
500 4,600 66.6 4F710-20
φ180
750 6,900 100.0 4F710-25

1,000 9,200 132.5 -

250 2,800 41.2 4F610-20

500 5,600 82.4 4F710-25


φ200
750 8,400 122.7 -

1,000 11,200 163.6 -

250 4,400 64.3 4F710-20

400 7,000 103.0 4F710-25


φ250
750 13,200 191.7 -

1,000 17,600 255.6 -

Intro 45
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time

Selection
*1: Refer to Intro Page 57 for piping specifications.

Suitable control components


Pneumatic auxiliary components Piping *1
Double solenoid Speed controller Silencer Piping (between valve and cylinder)
SC1-15 SLW-15A Rc1/2 steel pipe
4GB420-15
4KB420-15/4F520-15
SC-20A SLW-15A Rc1/2 steel pipe

SC-20A SL-20A,SLW-20S Rc3/4 steel pipe


4F620-20
SC-20A SL-20A Rc3/4 steel pipe
4GB420-15
SC1-15 SLW-15A Rc1/2 steel pipe
4KB420-15/4F520-15
SL-20A,SLW-20S Rc3/4 steel pipe
4F620-20 SC-20A
SL-20A Rc3/4 steel pipe

4F720-25 SC-20A SL-25A Rc1 steel pipe


4GB420-15
SC-20A SLW-15A Rc1/2 steel pipe
4KB420-15/4F520-15
4F620-20 SC-20A SL-20A Rc3/4 steel pipe

4F720-20 SC-20A SL-20A Rc3/4 steel pipe

- - - -
4KB420-15
SC-20A SLW-15A Rc1/2 steel pipe
4F520-15
4F720-20 SC-20A SL-20A Rc3/4 steel pipe

4F720-25 SC-25A SL-25A Rc1 steel pipe

- - - -

4F620-20 SC-20A SL-20A,SLW-20S Rc3/4 steel pipe

4F720-25 SC-25A SL-25A Rc1 steel pipe

- - - -

- - - -

4F720-20 SC-20A SL-20A Rc3/4 steel pipe

4F720-25 SC-25A SL-25A Rc1 steel pipe

- - - -

- - - -

Intro 46
System selection

STEP 3 Clean air system components selection


Select a component with a max. flow rate equal to or higher than the [required flow rate] value in Table 2.
When controlling multiple cylinders with a single set of clean air system components, select the clean air system component with [max. flow rate] higher than [total required flow rates].
Table 3
F.R.L kit F.R. unit
Max flow Max flow
Model No. Port size Model No. Port size
( Atm pressℓ/minconv value ) ( Atm press
ℓ/min
conv value )
C1000-6-W Rc1/8 450 W1000-6-W Rc1/8 800
C1000-8-W Rc1/4 630 W1000-8-W Rc1/4 1,150
C2000-8-W Rc1/4 1,200 W2000-8-W Rc1/4 1,500
C2000-10-W Rc3/8 1,700 W2000-10-W Rc3/8 2,000
C2500-8-W Rc1/4 1,200 W3000-8-W Rc1/4 2,150
C2500-10-W Rc3/8 1,700 W3000-10-W Rc3/8 2,430
C3000-8-W Rc1/4 1,280 W4000-8-W Rc1/4 2,500
C3000-10-W Rc3/8 1,750 W4000-10-W Rc3/8 4,350
C4000-8-W Rc1/4 1,430 W4000-15-W Rc1/2 4,750
C4000-10-W Rc3/8 2,400 W8000-20-W Rc3/4 10,000
C4000-15-W Rc1/2 3,000 W8000-25-W Rc1 10,000
C6500-20-W Rc3/4 4,500 B7019-1C Rc1/8 500
C6500-25-W Rc1 5,000 B7019-2C Rc1/4 900
C8000-20-W Rc3/4 7,000
C8000-25-W Rc1 7,500
K60570-1C-GB Rc1/8 200
K60570-2C-GB Rc1/4 300

Explanation of technical terms

[Theoretical reference speed]: indicates degree of cylinder speed, expressed as the following formula.
(This value coincides with speed at no load. When load is applied, speed drops considerably.)

VO =1920 × S S
A =2445 × D2 (1)
VO : Theoretical reference speed (mm/s)
A: Cylinder sectional area (cm2)
S: Composite effective cross-sectional area of circuit (exhaust air side) (mm2)
D: Cylinder bore size (cm)

When expressed as a graph, the theoretical reference speed is the speed within the
range where the cylinder moves at a uniform speed
VO = (mm/s)
Stroke ℓ

t3
t1: Time until movement starts
t2: Time of primary delay
t3: Operating time with constant velocity
: Stroke length

* Note/t1 and t2 differ depending on load. At no load, this can be ignored to no ill effect. Time

Intro 47
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time

Selection
■ F.R.L. kit, unit, regulator ■ Air filter ■ Lubricator
Primary pressure 0.7 MPa, set pressure Primary pressure 0.7 MPa, Primary pressure 0.5 MPa,
0.5 MPa, pressure drop 0.1 MPa pressure drop 0.02 MPa pressure drop 0.03 MPa

Air filter (F) Regulator (R) Lubricator (L)


Max flow Max flow Max flow
Model No. Port size ℓ/min Model No. Port size ℓ/min Model No. Port size ℓ/min
(Atm press conv ) (Atm press conv) (Atm press conv)
F1000-6-W Rc1/8 460 R1000-6-W Rc1/8 770 L1000-6-W Rc1/8 550
F1000-8-W Rc1/4 610 R1000-8-W Rc1/4 1,350 L1000-8-W Rc1/4 700
F2000-8-W Rc1/4 1,300 R2000-8-W Rc1/4 1,750 L3000-8-W Rc1/4 1,100
F2000-10-W Rc3/8 1,700 R2000-10-W Rc3/8 2,500 L3000-10-W Rc3/8 2,250
F3000-8-W Rc1/4 1,230 R3000-8-W Rc1/4 2,000 L4000-8-W Rc1/4 1,000
F3000-10-W Rc3/8 1,500 R3000-10-W Rc3/8 2,600 L4000-10-W Rc3/8 1,700
F4000-8-W Rc1/4 1,320 R4000-8-W Rc1/4 2,500 L4000-15-W Rc1/2 2,700
F4000-10-W Rc3/8 2,140 R4000-10-W Rc3/8 4,400 L8000-20-W Rc3/4 6,300
F4000-15-W Rc1/2 3,000 R4000-15-W Rc1/2 5,000 L8000-25-W Rc1 10,000
F6000-20-W Rc3/4 5,600 R6000-20-W Rc3/4 7,000 A3019-1C Rc1/8 100
F6000-25-W Rc1 6,200 R6000-25-W Rc1 7,700 A3019-2C Rc1/4 400
F8000-20-W Rc3/4 6,400 R8000-20-W Rc3/4 14,000 3003E-6C Rc3/4 3,500
F8000-25-W Rc1 6,800 R8000-25-W Rc1 11,000 3003E-8C Rc1 4,000
A1019-1C Rc1/8 550 B2019-1C Rc1/8 500
A1019-2C Rc1/4 700 B2019-2C Rc1/4 500
1138-6C-E Rc3/8 5,500 2215-6C Rc3/4 14,000
1138-8C-E Rc1 7,000 2215-8C Rc1 14,000
2215-10C Rc1 1/4 14,000

[Required flow rate]: indicates instantaneous flow rate for operating a cylinder with velocity VO , expressed with the following formula.
Values in the table are when P = 0.5 MPa. The required flow rate is a value necessary to select clean air system components.

Avo (P+0.101) × 60
Q≈ (2)
0.101×104
Q: Required flow rate ( /min) (ANR)
P: Supply pressure (MPa)

[Required effective sectional area]: indicates composite effective cross-sectional area for the exhaust circuit required for
moving the cylinder at speed VO .
(Composite effective cross-sectional area of valve, speed controller, silencer or piping)

[Proper standard system]: indicates the most appropriate combination of valve, speed controller, silencer and bore size for
operating a cylinder with velocity VO . The combination in the table is for a pipe length of 1 m.

Intro 48
System selection

A combination of the valve and the cylinder's standard system (example)


(1) The cylinder average speed is obtained from the combination of the valve and piping system. It is
expressed as the cylinder's piston speed calculated by dividing the stroke length by the time that the
piston rod takes from start to end of movement with the cylinder rod installed facing upward. When the
load factor is 50%, the average speed should be approximately the cylinder's piston speed multiplied by
0.5. (Refer to Intro Page 51 for the relation of load factor and theoretical reference speed. )
(2) The cylinder's average speed is that when one cylinder is operated independently.
(3) T
‌ he effective cross-sectional area of the solenoid valve used for the calculation below is the 2-position
value.
(4) This selection guide is for reference. Check the selection with actual conditions using a sizing program.
(5) Graph for the 4G and 4K Series valve (2-position single, base piping) is shown as an example.

4G Series (With internal exhaust check valve)

(Example) The connection component system No. is ●


2 for the 4G1 with a C6 port size.

Base piping
Series Solenoid valve Speed Composite effective System No.
Model No. Silencer Piping (1 m) cross-sectional area (mm2)
port size controller Pipe length (1 m)
M4GB110R C4 SC3W-6-4 SLW-6S φ4×φ2.5 1.4 ●
1
4G1
M4GB110R C6 SC1-6 SLW-6S φ6×φ4 2.8 ●
2

M4GB210R C6 SC1-8 SLW-8S φ6×φ4 4.5 ●


3
4G2
M4GB210R C8 SC1-10 SLW-8S φ8×φ5.7 6.7 ●
4

M4GB310R C10 SC1-10 SLW-10L φ10×φ7.2 10.1 ●


5
4G3
M4GB310R C10 SC1-15 SLW-10L φ12×φ8.9 11.5 ●
6

* The system No. is indicated in the following graph.


(mm/s)
1000

4
(Example) When using system ● 2 with φ40 cylinder diameter,

the cylinder's average speed is about 450 mm/s.


Cylinder average speed

750

3

5 (Note that this differs with working conditions.)

2

6

1
500

250

100
6 20 40 63 80 100(mm)

Cylinder bore size (φ)

Intro 49
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time

Selection
MN4G Series (With internal exhaust check valve)

Solenoid valve Composite effective


Series Speed controller Piping (1 m) Common exhaust piping System No.
port size X-sectional area (mm2)

C4 SC3W-M5-4 φ4×φ2.5 φ6×φ4×3 m 0.9 ●


1

MN4G1 C4 SC3W-6-4 φ4×φ2.5 φ6×φ4×3 m 1.4 ●


2

C6 SC1-6 φ6×φ4 φ8×φ5.7×3 m 2.8 ●


3

C6 SC1-6 φ6×φ4 φ8×φ5.7×3 m 3.8 ●


4
MN4G2
C8 SC1-8 φ8×φ5.7 φ10×φ7.2×3 m 6.0 ●
5

* The system No. is indicated in the following graph.


(mm/s) * This graph applies to common exhaust.
1000

750
Cylinder average speed


2 ●
3 ●
4 ●
5

500

1

250

0
20 30 40 50 63 (mm)
Cylinder bore size (φ)

4K Series
Solenoid valve Composite effective
Series Speed controller Silencer Piping (1 m) System No.
port size X-sectional area (mm2)

4KB110 C6 SC1-6 SLW-6S φ6×φ4 3.2 ●


1

4KB210 C8 SC1-8 SLW-8S φ8×φ5.7 7.7 ●


2

4KB310 C10 SC1-10 SLW-10L φ10×φ7.2 14.1 ●


3

4KB410 C15 SC1-15 SLW-15A φ12×φ8.9 23.6 ●


4

* The system No. is indicated in the following graph.


(mm/s)

1000

1

2 ●
3 ●
4
Cylinder average speed

800

600

400

200

6 10 16 20 32 40 50 63 80 100 125 140 160 180 (mm)

Cylinder bore size (φ)

Intro 50
System selection

Selecting from the load value and operation time

■ How to select
When load (N) and cylinder required operation time (S) are already decided, use [System
selection 2] to select an appropriate model. Follow the following procedures.

STEP 1 Confirming conditions


[Confirming conditions] (1) Load F= □ (N)
Load value (N), (2) Required operation time t = □ (s)
Required operation time (S) (3) Stroke L= □ (mm)
(4) Pressure P= □ (MPa)
M : Weight of body (kg)
μ : Friction coefficient (normally μ≈ 0.3)
F : Load (N)
g : 9.8 m/s2
Selecting cylinder bore size

From Graph 1 ● Vertical

Selecting theoretical reference speed


F=Mg
From Graph 2
● Horizontal

Selecting a suitable system


F=μMg
From Graph 3

Selecting suitable components

From Table 1
Intro 51
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time

Selection
STEP 2 Selecting cylinder bore size
According to the nomogram for cylinder bore size, select the cylinder bore size and read the load
factor at the same time. (Normally, for value F of “Step 1 Confirming conditions”, read the cylinder
bore size whose load factor is close to 50% )
Cylinder bore size D = φ□
(Example) When F = 800N , P = 0.5 MPa , cylinder bore size is φ63 at Load factor 50% .

Graph 1 Nomogram to find cylinder bore size

800

Load factor Load factor Load factor

Intro 52
System selection

STEP 3 Selecting theoretical reference speed


According to t-vo graph, read vo value to obtain the required operation time t (sec).

vo =□
‌ hen Load factor 50%
(Example) W and Stroke length of 200mm cylinder operate with 1.0sec ,

theoretical reference speed is 450 mm/s .

Graph 2 t-vo graph

Load factor 0% Load factor 25%


Pipe length 1 m Pipe length 1 m
Operation time t (s)
Operation time t (s)

Str
ok
el
en
gth
Str
ok
el
en
gth

Cylinder theoretical reference speed Cylinder theoretical reference speed

Intro 53
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time

Selection
Load factor 50% Load factor 70%
Pipe length 1 m Pipe length 1 m
Operation time t (s)

Operation time t (s)

Str
oke
len
gth
Str
oke
len
gth

Cylinder theoretical reference speed Cylinder theoretical reference speed


450

Intro 54
System selection

STEP 4 Selecting a suitable system


In the system selection table, find the cross point of vo obtained in [STEP 3 Selecting theoretical reference
speed] and φD obtained in [STEP 2 Selecting cylinder bore size], and from the cross point, trace a line extended
straight up to read the system code.

System code □
(Example) ‌In order to operate φ63 cylinder at theoretical reference speed 450 mm/s , C1 system is
ideal.

Graph 3 System selection table

C system D system
Cylinder theoretical reference speed V0 (mm/s)

450

Composite effective cross-sectional area of circuit S (mm2)

Intro 55
Selecting from cylinder bore size and operation speed
Selecting from the load value and operation time

Selection
STEP 5 Selecting suitable components
According to the standard system table, confirm the model No. of proper system components with the code
found in [STEP 4 Selecting a suitable system].

(Example) CI system
Valve □ Valve: Single 4KB210-08 or 4GB310R-08
Double 4KB220-08 or 4GB320R-08
Speed controller □ Speed controller: SCI-8
Silencer □ Silencer: SLW-8A
Piping □ Piping: φ10 x φ7.2 nylon tube 1 m

Table 1 Standard system table

Standard Valve Speed Composite eff


system Silencer Piping X-sect area
No. Single solenoid Double solenoid controller (mm2) pipe 1 m
4SB010-M5 4SB020-M5 SC3W-M5-4 φ4 × φ2.5
A SLM-M5 0.9
4KA110-GS4 4KA120-GS4 (SC-M5) Nylon tube

4KA110-GS6 4KA120-GS6 SC3W-6-6 SLM-M5 φ6×φ4


B1 2.0
4KB110-06 4KB120-06 SCL2-06-H66 SLW-6A Nylon tube

4KB110-06 SC1-6 SL-M5 φ8 × φ5.7


B2 4KB120-06 3.0
4GB110R-06 SCL2-08-H88 SLW-6A Nylon tube

4GB210R-06 SC1-6 SLW-6A φ8 × φ5.7


B3 4KB220-06 5.2
4KB210-06 SCL2-08-H88 SLW-6S Nylon tube

4GB210R-08 4GB220R-08 SC1-8 SLW-6A φ10×φ7.2


B4 6.4
4KB210-08 4KB220-08 SCL2-10-H1010 SLW-8A Nylon tube

4GB210R-08 4GB220R-08
SC1-8 SLW-8A φ10×φ7.2
C1 4KB210-08 4KB220-08 7.8
SCL2-10-H1010 SLW-8S Nylon tube
4F210-08 4F220-08

4GB310R-10 4GB320R-10 φ10 × φ7.2


C2 4F310-10 4F320-10 SC1-10 SLW-10A Nylon tube or Rc3/8 12
4KB310-10 4KB320-10 steel pipe

4GB410-15 4GB420-15
C3 4F510-15 4F520-15 SC1-15 SLW-15A Rc1/2 steel pipe 27
4KB410-15 4KB420-15

4GB410-15 4GB420-15
C4 4F510-15 4F520-15 SC-20A SLW-15A Rc1/2 steel pipe 38
4KB410-15 4KB420-15

D1 4F610-20 4F620-20 SC-20A SL-20A Rc3/4 steel pipe 64

D2 4F710-20 4F720-20 SC-20A SL-20A Rc3/4 steel pipe 80

D3 4F710-25 4F720-25 SC-25A SL-25A Rc1 steel pipe 112

Intro 56
System selection Supplemental materials

Effective cross-sectional area for steel pipes and nylon tubes, and recommended max. flow rate for gas pipes
Effective cross-sectional area of steel pipe Effective cross-sectional area of nylon tube
100
80
2000 60
2B
40
1000
Bore size
1 21 B 30
(mm)
1 41 B
20
500
φ10
1B
10 φ9
3 8 φ8
4 B φ7.5
6 φ7
φ6.5
100 2
1
B 4 φ6

Effective cross-sectional area (mm2)


3 φ5.5
3 φ5
8 B
50 2
φ4.5

φ4
1
4 B
1
Effective cross-sectional area (mm2)

0.8
1 φ3
8 B 0.6
10
0.4 φ2.5

0.3
5 φ2
0.2 φ1.8

0.1
0 0.5 1 2 3 5 10 20 0.5 1 2 3 4 6 8 10 20 30

Pipe length (m) Tube length (m)

Recommended max. flow rate table of gas tube


Nominal (Remarks)
1
/8B 1
/4B 3
/8B 1
/2B 3
/4B 1B 11/4B 11/2B
size In the main line where the piping distance tends to increase, it is
Pressure drop necessary to consider a pressure drop occurring at the end of the
0.124 0.0707 0.0576 0.0425 0.0276 0.0209 0.0133 0.0105
MPa (*1)
main line when air passes.
Inlet pressure
Recommended max. flow rate (ℓ/min) The recommended max. flow rate refers to the max. flow rate that
MPa
0.05 127 244 518 838 1,465 2,460 3,870 5,150 can be recommended in the range of allowable pressure drop with
0.1 146 282 598 965 1,690 2,828 4,460 5,950 respect to piping length, determined from actual use.
0.15 163 314 668 1,076 1,885 3,150 4,960 6,630
This does not mean that a higher flow is not possible, but rather that
0.2 179 344 730 1,180 2,060 3,450 5,430 7,280
0.3 206 395 840 1,360 2,375 3,900 6,300 8,400 the pressure will further decrease if the flow exceeds this value.
0.4 230 442 940 1,520 2,660 4,450 7,000 9,360
0.5 252 485 1,030 1,660 2,920 4,875 7,700 10,250
0.6 272 523 1,110 1,800 3,140 5,250 8,300 11,050
0.7 292 558 1,185 1,920 3,350 5,620 8,870 11,800
0.8 308 592 1,260 2,035 3,560 5,970 9,430 12,570
0.9 324 623 1,325 2,140 3,745 6,290 9,900 13,220
1.0 340 654 1,395 2,250 3,930 6,600 10,400 13,880
1.2 370 717 1,510 2,450 4,280 7,150 11,250 15,040
1.4 398 763 1,625 2,624 4,590 7,700 12,100 16,200
1.5 410 790 1,680 2,710 4,740 7,930 12,550 16,780

*1: ‌Inlet pressure = 0.5 MPa


Gas pipe length: 10 m

Intro 57
Flow characteristics display method

Selection
1. Flow characteristics display
The catalog specifications indicate the flow rate as follows.
Components Display Unit Standards
ISO 6358:1989 “Pneumatic fluid power - Components using compressible fluids
New JIS compliant indication C,b
- Determination of flow-rate characteristics” JIS B 8390:2000 (ISO 6358 translation)
Pneumatic JIS B 8373:1993 “Pneumatic 2-port solenoid valves”
JIS B 8374:1993 “Pneumatic 3-port solenoid valves”
components S
Conventional indication JIS B 8375:1993 “Pneumatic 4, 5-port solenoid valves”
JIS B 8379:1995 “Pneumatic noise reduction device”
Cv ANSI(NFPA)T3. 21. 3:1990

2. Explanation
The flow characteristics of the solenoid valves were conventionally indicated with the effective cross-sectional area S. However, JIS
was revised (JIS B 8390:2000), and these are now indicated with the sonic conductance C and critical pressure ratio b.

● Sonic conductance C: Value obtained by dividing the passage weight flow of the
component in the choke flow by the sum of the upstream absolute

Mass flow rate


pressure and standard state density. (sonic conductance) S ≈ 5.0 C
(Conventional sizing is possible with C.)
● Critical pressure ratio b:  Pressure ratio at which choked flow results if smaller than this value
(downstream pressure/upstream pressure) (critical pressure ratio)
● Effective cross-sectional area S (mm2): 
The value of the ideal restricted cross-sectional area without friction Critical
or compressed flow, calculated from the pressure changes inside pressure
the air tank when the choke flow is released from the components ratio b
mounted on the air tank.
Subsonic flow Choked flow
* Choke flow: Flow at which upstream pressure is higher than downstream pressure, and speeds at certain
sections of components reach acoustic velocity. The fluid’s mass flow rate is proportional to
the upstream pressure, and is not dependent on downstream pressure. (Choked flow) Fig. 1 ‌Mass flow characteristics for
upstream pressure
Flow rate formula

Depending on the actual unit, they are shown as follows.

Q : Air flow rate [dm3/min(ANR)], SI unit


P2+0.1 dm 3 (cubic decimeter) can also be
Choked flow when ≤b expressed with ℓ (liter). 1dm3 = 1ℓ
P1+0.1
C : Sonic conductance [dm3/(s·bar)]

293 b : Critical pressure ratio [-]


Q=600×C(P1+0.1) ………………(1) P1 : Upstream pressure [MPa]
273+t
P2 : Downstream pressure [MPa]
P2+0.1 t : Temperature (°C)
Subsonic flow when >b
P1+0.1

2
P2+0.1
-b 293
Q=600×C(P1+0.1) 1- P1+0.1 ………………(2)
273+t
1-b

To calculate effective cross-sectional area S, substitute the value C obtained with C = S/5 above in the above formula.
For subsonic flow, substitute b = 0.5 in formula (2).

Intro 58
Safety Precautions
Be sure to read this section before use.

When designing and manufacturing equipment using CKD products, the manufacturer is obligated
to ensure that the safety of the mechanism, pneumatic control circuit and/or water control circuit
and the system that runs the electrical controls are secured.
It is important to select, use, handle and maintain CKD products appropriately to ensure their safe
usage.
Observe warnings and precautions to ensure device safety.
Check that device safety is ensured, and manufacture a safe device.

WARNING
1 This product is designed and manufactured as a general industrial machine part.
It must be handled by an operator having sufficient knowledge and experience.

2 Use this product in accordance with specifications.


This product must be used within its stated specifications. In addition, never modify or additionally machine this product.
This product is intended for use in general industrial machinery equipment or parts. It is not intended for use
outdoors (except for products with outdoor specifications) or for use under the following conditions or environments.
(Note that this product can be used when CKD is consulted prior to its usage and the customer consents to CKD
product specifications. The customer should provide safety measures to avoid danger in the event of problems.)
●1 Use
‌ for applications requiring safety, including nuclear energy, railways, aircraft, marine vessels, vehicles, medical devices, devices or applications in
contact with beverages or foodstuffs, amusement devices, emergency cutoff circuits, press machines, brake circuits, or safety devices or applications.
●2 Use for applications where life or assets could be significantly affected, and special safety measures are required.

3 Observe organization standards and regulations, etc., related to the safety of the device design and control, etc.
ISO4414, JIS B 8370 (General rules for pneumatic systems)
JFPS2008 (Principles for pneumatic cylinder selection and use)
Including the High Pressure Gas Safety Act, Industrial Safety and Health Act, other safety rules, organization
standards and regulations, etc.

4 Do not handle, pipe, or remove devices before confirming safety.



1 Inspect and service the machine and devices after confirming safety of the entire system related to this product.

2 Note that there may be hot or charged sections even after operation is stopped.


3 When inspecting or servicing the device, turn OFF the energy source (air supply or water supply), and turn
OFF power to the facility. Discharge any compressed air from the system, and pay enough attention to
possible water leakage and leakage of electricity.

4 When starting or restarting a machine or device that incorporates pneumatic components, make sure to
secure system safety, such as pop-out prevention measures.

5 Observe the warnings and cautions on the following pages to prevent accidents.

■ Precautions are ranked as “DANGER”, “WARNING”, and “CAUTION” in this section.

DANGER: In the case where the product operation is mishandled and/or when the urgency of a
dangerous situation is high, it may lead to fatalities or serious injuries.

WARNING: A dangerous situation may occur if handling is mistaken, leading to fatal or serious
injuries.

CAUTION: A dangerous situation may occur if handling is mistaken, leading to minor injuries or
property damage.

Note that some items indicated with “CAUTION” may lead to serious results depending on the conditions.
All items contain important information and must be observed.

Intro 59
Limited warranty and disclaimer
1 Warranty period

Caution
This warranty is valid for one (1) year after delivery to the customer’s designated site.

2 Scope of warranty
In case any defect clearly attributable to CKD is found during the warranty period, CKD shall, at its own
discretion, repair the defect or replace the relevant product in whole or in part and at no cost, according to its
own judgment.

Note that the following failures are excluded from the warranty scope:
(1) Failures due to use outside the conditions and environments set forth in the catalog or these specifications.
(2) Failures resulting from factors other than this product
(3) Failures caused by improper use of the product.
(4) Failures resulting from modifications or repairs made without CKD consent.
(5) ‌Failures caused by matters that could not be predicted with the technologies in practice when the product
was delivered.
(6) Failures resulting from natural disasters or accidents for which CKD is not liable.

The warranty covers the actual delivered product, as a single unit, and does not cover any damages resulting
from losses induced by malfunctions in the delivered product.

3 Compatibility check
The customer is responsible for confirming the compatibility of CKD products with the customer’s systems,
machines and equipment.

Precautions for export


1 Security Trade Control
The products in this catalog and their related technologies may require approval before export or provision.
For the sake of maintaining world peace and safety, there may be cases in which approval under the Foreign
Exchange and Foreign Trade Control Law is required in advance, depending on the country to where the
product or related technology is being exported or provided.
The scope of products and related technologies requiring approval are listed in the Export Trade Control Order
Appendix Table 1 or Foreign Exchange Order Appendix Table.
The Export Trade Control Order Appendix Table 1 and Foreign Exchange Order Appendix Table contain the
following two types of information.
· “List controls” specified for items 1 to 15
· “Catch-all controls” that do not indicate specifications by item, but restriction by application (Section 16)

List control, which is specified in item 1 to 15


(When product could be used for weapons of mass destruction or for development of regular arms, etc.)
Listed in the “Export Trade Control Order Appendix Table 1” or
Products that require
“Foreign Exchange Order Appendix Table”
authorization
or the range of
relevant technology Catch-all control restricted by application (item 16)

Listed in the “Export Trade Control Order Appendix Table 1” or


“Foreign Exchange Order Appendix Table”
An application for approval is
received by the Security Export Licensing Division of the Ministry of Economy, Trade and Industry or
local bureaus of the Ministry of Economy, Trade and Industry.

2 Products and related technologies in this catalog


The products and related technologies in this catalog are subject to the catch-all control of the Foreign
Exchange and Foreign Trade Control Law.
When exporting or providing the products or related technologies in this catalog, ensure that they are not used
for arms or weapons.

3 Contact
Contact your local CKD Sales Office for information on the Security Trade Control of products and related
technologies in this catalog.

Intro 60
Design/selection
■ Take measures to prevent physical harm or property
1. Checking the specifications
damage in the event of failure of this product.
WARNING CAUTION
■ Use the product in the range of conditions specified
■ Check for leakage current to avoid malfunction caused
for the product.
by leakage current from other fluid control components.
The product in this catalog is designed for use only in a compressed air
system. Use with pressure or temperature exceeding the specifications ● When using a programmable controller, leakage current
may affect the solenoid valve and cause malfunction.
range may result in damage or operation faults. (Refer to specifications)
Note that the values that are affected by leakage current
Contact CKD when using fluids other than compressed air.
depend on the solenoid valve.
Programmable controller
2. Safety design
WARNING
■ Understand the characteristics of compressed air
before designing a pneumatic circuit.
● The same functions as the mechanical, hydraulic, and
electrical methods cannot be anticipated if instantaneous Using 100 VAC 3.0 mA or less (*1)
stopping and holding are required during an emergency stop. Using 200 VAC 1.5 mA or less
● Pop-out, air discharge, or leakage due to air compression Using 12 VDC 1.5 mA or less (*2)
and expansion may occur. Using 24 VDC 1.8 mA or less (*2)
● The supply and exhaust of the valve must operate simultaneously. *1: 1.2 mA or less for the 4G Series.
When the supply is operated in advance, the actuator *2: 1.0 mA or less with the MN4S0 series, 4S0 series, and 3M0 series.
switching will be delayed.
When the exhaust is operated in advance, the actuator speed ■ Observe the following precautions when using
will be uncontrollable, causing the popping out phenomenon.
nylon tubes or urethane tubes for piping material.
● Use flame-resistant tubes or metal steel pipes in an
■ Make sure that the switching signals of the
environment where spattering may occur.
2-position and 3-position double solenoids are ● Use hydraulic hose when piping is for both hydraulic and
never energized at the same time. pneumatic use.
● When using the standard push-in fitting on the spiral tube,
■ When using a 3-position all ports closed valve with fix the base of the tube with a hose clamp.
a custom stroke, the properties of compressed air Rotation may occur, causing a reduction in holding force.
make it impossible to brake at an accurate position. ● Use a fastening fitting in a high-temperature atmosphere.
The push-in fitting cannot be used.
In addition, as valves and cylinders, etc., are designed
to allow small volumes of air leakage, pressure retention
applications are not available, as they may cause the 3. Working environment
stop position to change or cause a pressure drop.
WARNING
■ Pay attention to the electric circuit during emergency ■ Confirm before use that the product will withstand
stop and to the cylinder operation during power outages. the working environment.
● If the 2-position double solenoid is started and then switched, it will hold
● This product cannot be used in an atmosphere containing
that status unless a reverse operation electrical signal is input.
corrosive gas, chemical liquids, solvents, water or steam. If
water, oil, or metal chips (spatter or cutting chips, etc.) could
■ Install
 a “pressure switch” and “shut-off valve” on come in contact with the product, provide appropriate protection.
the device’s compressed air supply side. ● Consult with CKD if ozone is generated in the supplied
● The pressure switch will disable operation until the set pressure air. (Ozone-proof products are available.)
is reached. The shut-off valve releases compressed air into the ● Products other than explosion-proof solenoid valves cannot
pneumatic pressure circuit to prevent accidents caused by be used in an atmosphere containing explosive gas.
operation of pneumatic components under residual pressure.
■ Install the product where it will not be exposed to
Valve

Cylinder
rain, water, direct sunlight, or high temperatures.
Compressor
Shut-off valve Pressure switch
(The explosion-proof 4F ** OE series and outdoor 4F-W
series are available for outdoor use.)

■ Do not use this product in a corrosive environment.


■ Do
 not constrict the air supply piping. Use in such an environment could lead to damage or
● A drop in pressure due to simultaneous operation of operation failure.
multiple stations may cause malfunctions.
Intro 61
■ Usedry compressed air that does not cause
CAUTION

Caution
moisture inside the piping.
■ Use clean air.
● If compressed air contains chemicals, synthetic oils
containing organic solvents, salt, or corrosive gas, do not
use as it can cause damage and/or operation failure.

4. Durability
Air filter
WARNING (5 μm or less)
Dryer
■ Decide on a method of lubricating pneumatic
components, and provide correct maintenance. ● Moisture will occur if the temperature drops in the
● Is it a no-lubrication? pneumatic piping or pneumatic components.
● Is it a lubrication? ● Operation faults could occur if moisture enters the air flow path
of pneumatic components and temporarily blocks passage.
Specify either of the above for control of lubricant.
● Moisture could cause rust, making the pneumatic
components fail.
■ Ultra dry air is not suitable for pneumatic components. ● The drain will flush the lubricant oil and cause a
● Ultra dry compressed air will shorten the life of pneumatic lubrication defect.
components. For use, be sure to use a solenoid valve for
DC voltage drive.
■ Usecompressed air that does not contain oil
■ Continuous energizing during use may accelerate oxides, tar, carbon, etc., from the air compressor.
degradation of the solenoid valve. Contact CKD ● If oil oxides, tar, or carbon enter the pneumatic
components and solidify, resistance at the sliding section
when using the solenoid valve under such conditions. will increase, leading to operation failure.
● When using a product with continuous energization, be ● If the supplied lubricant mixes with oil oxides, tar, carbon,
sure to use items with DC voltage specifications or fluoro etc., the sliding section of the pneumatic component
rubber specifications. could be worn down.

5. Pneumatic source ■ Use compressed air that does not contain solid
foreign matter.
CAUTION ● Any solid foreign matter in the compressed air can enter
■ Install
the pneumatic components and cause wear or locking in
a pneumatic filter just before the pneumatic
the sliding parts.
component in the circuit.

Air filter
(5 μm or less)

■ Do not supply anything other than compressed air.

■ Use clean compressed air that does not contain


corrosive gases.

Intro 62
6. Usage method 8. Clearly indicated in the instruction manual
WARNING CAUTION
■ Do not narrow the exhaust port of the manifold valves. ■ Indicate the maintenance conditions in the device’s
● There may be cases where other cylinders are subject to instruction manual.
unintended operation due to back pressure generated from ● The product's performance may drop too low to maintain
the exhaust of the switching valve. In this case, individually an appropriate safety level depending on usage
install a manifold two-sided exhaust type or a single exhaust conditions, working environment and maintenance status.
spacer equipped type with the valve causing the situation. With correct maintenance, the product functions can be
used to the fullest.
CAUTION
■ Make sure that the instantaneous energizing/
manual override of the double solenoid 2 position
valve is 0.1 seconds or more.
However, as the cylinder may malfunction due to
secondary side load conditions, it is recommended
that energizing/manual override is performed until
the cylinder reaches the stroke end position.

■ Formanual override of the push type, push the


manual override straight.

■ Do not use the product with the air supply port


throttled or released to atmospheric pressure.

Do not restrict the


air supply port!

● With the internal pilot, the supply pressure may drop lower
than the specified range and cause malfunctioning. In this
case, use the external pilot.

■C
 ontinuous energizing for long periods may
accelerate degradation of the solenoid valve. Consult
with CKD when energizing this device continuously.
Furthermore, use caution under the following
working conditions, as with continuous energization:
-W‌ hen performing continuous energizing for a long
period of time or when the energized time in a single
day will be longer than the non-energized time
Install with an eye to heat dissipation.

■W
 ith the internal pilot solenoid valve, turn the power
on after applying the supply pressure.
The main valve may stop at an unintended position
and prevent proper switching.

7. Securing of space
CAUTION
■ Secure sufficient space around the solenoid valve
for installation, removal, wiring, and piping work.

Intro 63
Mounting, installation and adjustment

Caution
1. Installation 2. Pre-operation confirmation
WARNING CAUTION
■ When mounting a valve, do not use a mounting ■ When supplying compressed air after connecting
method that relies on support from the piping. pipes, do not suddenly apply high pressure.
● Mount and fix the valve body. ● The pipe connection could dislocate, causing the pipe
tube to fly out, leading to accidents.
■ After mounting, do not clean or paint with water or solvent. ● Caution: If compressed air is supplied too slowly, sealing pressure
● Otherwise some resin parts may be damaged. may not be generated depending on the internal sealing
● Paint could plug the pilot exhaust port and result in malfunctions. mechanism of the solenoid valve and may cause air leakage.

■ Do not narrow the exhaust port to a smaller one ■ As air leakage may occur when compressed air is
than the bore size of the piping connection port. supplied with the two 3-port valves integrated
(The pilot exhaust port is also included as an (differential pressure return) without piping to the
exhaust port) output port, be sure to supply the compressed air
● Either attach a silencer or install a solenoid valve so that after piping the output port.
the exhaust port is facing downwards.
An inhale effect may be generated at the exhaust port ■ Before supplying compressed air after connecting pipes,
due to valving element operations and cause the intake of check that there are no air leaks at any pipe connections.
foreign matter near the exhaust port. ● Apply a leakage detection agent to pipe connections with
If the exhaust port is facing upwards, foreign matter may a brush and check for air leaks.
fall into it.
● The actuator will not operate correctly if the exhaust air is not
discharged smoothly. With the manifold, the exhaust air may 3. Adjustment
prevent the correct operation of other solenoid valves.
WARNING
■ Do not block the pilot exhaust port (PR port).
■ When the manual operation device of the solenoid
● Pilot pressure will not be discharged and will fail to operate.
valve has been operated, always be sure to operate
■ Remove the valve packaging and dust-proof seal of the device after reset to the origin (default position).
the piping port just before starting piping. Be sure to check that the non-locking has
● Removing the dust-proof seal of the piping port before the automatically returned or that the locking is in a
piping work starts could allow foreign matter to enter the state where the lock is released (OFF state).
valve from the piping port and cause failure or misoperation.
[Example] OFF OFF
■ Check that tubing is not worn or damaged.
● Tubing could collapse, rupture, or become dislocated. ON ON

When locked Unlocked

Note: ‌As this varies depending on the model, refer to the


pages of each model for operation methods.

● The solenoid valve will operate as soon as the pneumatic


source power is turned ON, which is hazardous.
● When the manual override device is used for operation at
the operating position, abnormal operation is a risk.

Intro 64
■ Connect piping so that connections are not
4. Piping
dislocated by equipment movement, vibration, or
CAUTION tension.
● Control of actuator speed will be disabled if piping on the
■ When connecting pipes, wrap sealing tape in the exhaust side of the pneumatic circuit is disengaged.
opposite direction from the threading, from the ● When using the chuck holding mechanism, the chuck
inside position to within 2 mm from the pipe end. may be released, creating a hazardous state.
● Cut the push-in fitting tube at right angles with a dedicated
● If sealing tape protrudes from the pipe threads, it could be
tool.
cut when screwing the bolts in. This could cause the tape
● Confirm that the tube has been inserted properly, and
to enter the solenoid valve, causing failures.
make sure that there is no tension during use. The tube
could be dislocated or damaged if there is any tension.
Solid Solid
liquid liquid
sealant sealant ■ Make
sure that there is no torsion, tension or
moment load applied to the fitting or the tube.

■ Use the designated tube.


OK OK ● Particularly in the case of super-flexible urethane tubes,
attach insert sleeves for use.

■ Alwaysflush just before piping pneumatic ■ Securely insert the tube to the tube end, and make
components. sure that the tube cannot be pulled off.
● Any foreign matter that has entered during piping must be
removed so it does not enter the pneumatic components.
■ Cut the tube with a dedicated cutter and always at
a right angle.

Removing
foreign matter

■ Useappropriate torque to tighten the pipes


when connecting them.
● The purpose is to prevent air leakage
and damage to bolts.
First tighten the bolts by hand to
ensure that the threads are not
damaged, then use a tool.

Port thread Tightening torque N·m

M3   0.3 to 0.6
M5  1.0 to 1.5
Rc 1/8   3 to 5
Rc 1/4   6 to 8
Rc 3/8 13 to 15
Rc 1/2 16 to 18
Rc 3/4 19 to 40
Rc 1 41 to 70

■ When piping to the product


Properly connect pipes by confirming the piping
port position with the display, etc., on the product.
Incorrect piping may cause irregular operation of
the actuator.

Intro 65
Use/maintenance

Caution
1. Maintenance and inspection 2. Removal
WARNING WARNING
■ When the manual operation device of the valve has ■ Beforeconducting maintenance, turn the power
been operated, always be sure to operate the OFF, stop the supply of compressed air and make
device after reset to the origin (default position). sure that there is no residual pressure.
Be sure to check that the non-locking has ● Observe the conditions to ensure safety.
automatically returned or that the locking is in a
state where the lock is released (OFF state).
[Example]
OFF OFF Power supply
OFF
ON ON

When locked Unlocked

Note: A
‌ s this varies depending on the model, refer to the 3. Disassembly/assembly
pages of each model for operation methods.
WARNING
● The solenoid valve will operate as soon as the power is
turned ON, which is hazardous. ■ Read the relevant product’s instruction manual
● When the manual override device is used for operation at thoroughly and fully familiarize yourself with the
the operating position, abnormal operation is a risk.
task before disassembling or assembling the
■ Conduct daily inspections and regular inspections to solenoid valve.
ensure that maintenance control is done correctly. ● Personnel must be fully familiar with solenoid valve structure
and operational principles and safety requirements.
● If maintenance is not correctly managed, the product's
● Pneumatic Pressure Skill Test Class 2 or higher level is
functions could deteriorate markedly and lead to a
required.
shortened service life, faults and accidents.

1. Pressure management of supplied compressed air pressure 4. Pneumatic source


● Is the set pressure supplied? Does the pressure gauge
indicate the set pressure while the equipment is operating?
CAUTION
■ The no-lubrication function cannot be maintained
Max.
once lubrication has been applied to a no-
lubrication valve.
Once lubrication has been applied, it will be
Min. necessary to continue lubricating the valve.
● Decide on lubrication or no-lubrication for the pneumatic
components and ensure that implementation of the
2. Control of pneumatics filter corresponding method is properly managed.
● Is the drain correctly discharged? ● With the lubrication method, lubricants other than class 1
Is the bowl or element clean enough to use? turbine oil ISO VG32 (no additives) cannot be used.

3. Control of compressed air leaks from piping connections


● Is the state of the connection, especially at movable
sections, normal?

4. Valve operational status control


● Are operations delayed? Is exhaust normal?

5. Control of pneumatic actuator operation


● Is operation smooth? Is the end stop state normal?
Is coupling with the load normal?

6. Lubricator control
● Is the oil volume adjustment normal?

7. Lubricant control
● Is the lubricant that is being supplied an official item?
Intro 66
Reduced wiring valve / product-specific cautions (MN4E, M(N)4G AB , MW4G2, MW4G4, MN4S0, M(N)4TB Series)

CAUTION
Install the wiring while sufficiently checking the polarity, voltage, and terminal numbers.
● Voltage drop may occur due to simultaneous energizing or cable length.
Confirm that the voltage drop for the solenoid is within 10% of the rated voltage.

(1) Serial transmission (with T6*, T7*, and T8*) (2) Connector (T50, T50A)

● These models are dedicated for use with a working ● As it is necessary to match the signal arrangement of the
voltage of 24 VDC. PLC output unit with the signal arrangement on the valve
side, direct connections with a PLC are currently limited.
● If operation may be affected by noise, wire the power supply Establish connections with wiring connection examples
independently for each manifold solenoid valve when possible. (MN4E series: page 834, M4G AB /MN4G AB series: page 722,
MN4S0 series: page 1194, M4TB/MN4TB series: page
● Keep the power supply cable as short as possible. 1128) as a reference. For the cables, use dedicated
cables for each PLC manufacturer.
● Do not share power with an inverter or components
causing motor noise, etc. ● These models are dedicated for use with a working
voltage of 12 and 24 VDC.
● Do not lay the power wire, signal wire, and other power
● When connecting the T50, T50A type to a general output
cables in parallel.
unit, use the + terminal (20, 10) of the 20P connector as
the + side common, and use the NPN transistor output
● The slave units are dedicated for each manufacturer.
open collector type for the drive circuit.
There is no compatibility.
Contact CKD when using the PNP transistor output.

● For how to wire the slave unit, follow the instructions provided ● When wiring of the T50, T50A has been installed
from the PLC manufacturer. The terminal numbers of the slave according to the wiring connection examples (M4TB,
unit are displayed on the attachment side of the slave unit. MN4TB series: page 1128), supply the power supply from
the terminal included as an accessory.
● For information regarding the PLC, please contact the In this case, be sure not to make a mistake with the
corresponding PLC manufacturer. polarity. Making a mistake will cause a short circuit.
Contact CKD for inquiries regarding the UNIWIRE system (embedded fuse will blow)
and SAVE NET.
● Do not connect this solenoid valve to the input unit as
● When installing a manifold solenoid valve vertically, install major faults could occur in this device and in peripherals.
the slave unit at the top end. Connect this solenoid valve to the output unit.
Although common connectors are employed with the input
● With the T8* series, be sure to use waterproof caps and units and output units of the relay terminal series by
waterproof plugs on connectors of the I/O slave units that OMRON and Panasonic Electric Works Co., Ltd., the pin
will not be used. arrangement and polarity of the power supply are different.
The pin arrangement of the T50 type of this solenoid valve
aa
bb

is the same pin arrangement as the above output unit.


aa
bb

A
PU
SH
O
N
B
PU

A
SH
O
N
B

C 020
N

KD
4S
C 02
N

KD 0
4S

CAUTION
■ Install
so that no force is applied to the connector
section. The fixing screws may loosen if force is
applied to the connector section.
● The connector rotates upwards and sideways.
T6* T7* Further fasten the fixing screws after installation of the
(4G Series)
solenoid valve can fix the connectors.
● Make sure that the tightening torque of the fixing screws
is 0.3 to 0.36 N·m.
12
/14
a
b
a

1P
b

A
PU
SH
O
N
B

A
PU
SH
O
N
B

C 020
N

5R
KD
4S

2B /
C 020
N

KD

2B
4S

2B

2B

4A

T7* T8*
(MN4E Series) Fixing screw
(W4G2 Series)

Intro 67
Reduced wiring valve / product-specific cautions (MN4E, M(N)4G AB , MW4G2, MW4G4, MN4S0, M(N)4TB Series)

Caution
CAUTION (4) Terminal block (T10, 11)
(3) Connector (T30, T31, T51, T52, T53, TM*) ● Install the terminal block in a location that is out of reach
or place a cover on the unit.
● These models are dedicated for use with a working
voltage of 12 and 24 VDC.





A

PU
SH
O
N
B
● Use the 4S0 Series with the + common.
A

PU
SH
O
N
B

C 020
N

KD
4S
C 020
N

KD
4S
CAUTION
■ Install
so that no force is applied to the connector
section. The fixing screws may loosen if force is
applied to the connector section.
● The connector rotates upwards and sideways.
Further fasten the fixing screws after installation of the
solenoid valve can fix the connectors.
● Make sure that the tightening torque of the fixing screws T10 terminal T11 terminal
is 0.3 to 0.36 N·m. appearance appearance



A
PU
SH
O
N
B

A
PU
SH
O
N
B

C 020
N

KD
4S
C 020
N

KD
4S

Fixing screw

(5) Multi-connector (T20)

● Be sure to disconnect the power supply before inserting/


removing the connectors.

● Plug the connectors in all the way to ensure that the lock
is engaged.

1P

2B 3/5R

2B

2B

2B
4A

4A

4A

4A

4A

Intro 68
Electrical connection list (Single valve/individual wiring manifold)
* Refer to Intro Pages 30 to 33 for reduced wiring manifolds.
● Selection of electrical connections, manual operating devices, and options : Yes
Description Voltage (V) Electrical
Series
Page (Power consumption W) connections
3QR Series 1505 1 2 3 4 5 Grommet lead wire

6 7 8 9 10 1 Circuit diagram a

Standard *1 11 12 13 14 15
12 VDC (2.0 W)
24 VDC (1.8 W) 16 17 18 19 20
21 22 23 24 25
*1: ‌Some models differ depending on the
specifications. 26 27 28 29 30

3M Series 1541
Standard
1 2 3 4 5
6 7 8 9 10
24 VDC (0.6 W)
Option 11 12 13 14 15
12 VDC (0.6 W) 16 17 18 19 20 Compact terminal box
6 VDC (0.9 W)
5 VDC (0.9 W) 21 22 23 24 25 6 None S
Circuit diagram b
26 27 28 29 30

Miniature pneumatic valve series 1 2 3 4 5


2, 3-port valve

P/M/B5123 1583 Standard


100 VAC (1.8/1.4 W)
6 7 8 9 10

200 VAC (1.8/1.4 W) 11 12 13 14 15


( 50/60 Hz) 16 17 18 19 20
12 VDC (1.8 W)
*1: ‌The A type connector is only supported with 24 VDC (1.8 W)
21 22 23 24 25
manifolds. 26 *1 28 29 30

3P Series 1557 Standard


100 VAC (1.8/1.4 W)
*1
1 2 3 4 5
11
DIN terminal box
None
6 7 8 9 10
200 VAC (1.8/1.4 W) Circuit diagram a
( 50/60 Hz) 11 12 13 14 15
24 VDC (1.8 W)
Option 16 17 18 19 20
110 VAC ( 50/60 Hz)
220 VAC ( 50/60 Hz) 21 22 23 24 25
12 VDC
*1: Some models in the 3P series differ in part. 26 27 28 29 30

4K Series  1231 Standard


100 VAC (1.8/1.4 W)
1 2 3 4 5

(3KA1) 200 VAC (1.8/1.4 W)


6 7 8 9 10
( 50/60 Hz) 11 12 13 14 15
24 VDC (1.8 W)
Option 16 17 18 19 20 Round terminal box with light
110 VAC ( 50/60 Hz)
220 VAC (50/60 Hz) 21 22 23 24 25 16 + Ground (A-15a) equipped
Circuit diagram f
12 VDC
26 27 28 29 30

Miniature pneumatic valve series 1 2 3 4 5


Single valve 1583 Standard 6 7 8 9 10
W2P51* 100 VAC (1.8/1.4 W)
200 VAC (1.8/1.4 W) 11 12 13 14 15
P/B5142 ( 50/60 Hz)
16 17 18 19 20
Individual wiring manifold 12 VDC (1.8 W)
B*5142 24 VDC (1.8 W) 21 22 23 24 25
N*5142 26 27 28 29 30
C type connector
4S0 Series  1205 Standard
1 2 3 4 5
21 None N S L
6 7 8 9 10
24 VDC (0.6 W) Circuit diagram g
Option 11 12 13 14 15
12 VDC (0.6 W) 16 17 18 19 20
4, 5-port valve

6 VDC (0.9 W)
5 VDC (0.9 W) 21 22 23 24 25
26 27 28 29 30

4K Series  1231 Standard


100 VAC (1.8/1.4 W)
1 2 3 4 5
6 7 8 9 10
200 VAC (1.8/1.4 W)
( 50/60 Hz) 11 12 13 14 15
24 VDC (1.8 W)
Option 16 17 18 19 20 D type connector
110 VAC ( 50/60 Hz)
220 VAC (50/60 Hz) 21 22 23 24 25 26 None N S L
Circuit diagram g
12 VDC
26 27 28 29 30

4F Series  1337 Standard


100 VAC (1.8/1.4 W)
1 2 3 4 5
6 7 8 9 10
200 VAC (1.8/1.4 W)
( 50/60 Hz) 11 12 13 14 15
24 VDC (1.8 W)
Option 16 17 18 19 20
110 VAC ( 50/60 Hz)
220 VAC ( 50/60 Hz) 21 22 23 24 25
12 VDC (4F0, 4F1 standard)
26 27 28 29 30

Intro 69
Refer to the next page for circuit diagrams a to h .

Caution
Electrical connections None : Without lead wire I : With lead wire L : With indicator lamp
(wiring method) S : With surge suppressor N : Without socket

Grommet lead wire Conduit lead wire Compact terminal box (G1/4) Compact terminal box
2 S 3 4 None 5 None L
Circuit diagram b Circuit diagram a Circuit diagram a Circuit diagram c

Lead wire 300mm


90°

Compact terminal box Terminal box Terminal box Terminal box


7 I L 8 None 9 None L 10 None L S
Circuit diagram d Circuit diagram a Circuit diagram c Circuit diagram c

Lead wire length 300mm

DIN terminal box Round terminal box Round terminal box Round terminal box
12 None L 13 (G1/2 / G3/4) 14 L 15 + Ground (A-15a) equipped
Circuit diagram c Circuit diagram e Circuit diagram f Circuit diagram e

Refer to the
next page
for circuit
C type connector C type connector C type connector C type connector diagrams
17 I 18 None 19 I S L 20 None S L of the electrical
Circuit diagram a Circuit diagram a Circuit diagram g Circuit diagram g connections.

Lead wire 300mm Lead wire 300mm


(11/ 0.16) (11/ 0.16)

D type connector D type connector D type connector D type connector


22 I 23 None 24 I S L 25 None S L
Circuit diagram a Circuit diagram a Circuit diagram g Circuit diagram g

Lead wire 300mm

Lead wire 300mm

A type connector A type connector A type connector Terminal block


27 I S L 28 S L 29 N S L 30 VA connector
Circuit diagram g Circuit diagram g Circuit diagram g
4T only *1

*2: The voltage of the 4T series is similar to 4K and the electrical connections are NO.30.

Intro 70
Electrical connection list (single valve/individual wiring manifold)
● Selection of electrical connections, manual operating devices, and options : Yes
Voltage (V)
Series Page (Power Electrical
consumption W)
connections
Grommet lead wire
31 I
4G1 to 3 Series 7
31 32 33 34 35 36 Circuit diagram a
100 VAC
24 VDC (0.6 W) 37 38 39 40 41 42
MN4G Series 221 12 VDC (0.6 W)
3, 5-port valve

43 44 45
100 VAC

4G4 Series 599


110 VAC
24 VDC (1.0 W)
12 VDC (1.0 W)
31 32 33 34 35 36 Note) 100 VAC is not compatible.
100 VAC
W4G2 Series 863 24 VDC (0.6 W)
12 VDC (0.6 W)
37 38 39 40 41 42
37
E type connector
with socket/terminal
43 44 45 S L Circuit diagram g

100 VAC 31 32 33 34 35 36

W4G4 Series 1003


110 VAC
24 VDC (1.2 W)
37 38 39 40 41 42
12 VDC (1.2 W) 43 44 45
5-port valve

100 VAC 200 VAC 31 32 33 34 35 36

PV5G Series 1437


110 VAC 220 VAC
24 VDC (1.2 W)
37 38 39 40 41 42
12 VDC (1.2 W) 43 44 45
DIN terminal box
31 32 33 34 35 36 44 S L

PV5 Series 1465 24 VDC (1.2 W) 37 38 39 40 41 42


43 44 45
3, 4-port valve

MN4E0 Series 763


24 VDC (0.6 W)
12 VDC (0.6 W)
46 47

MN4S0 Series 1165 48

Circuit diagram
With surge suppressor and
a Basic c With indicator lamp f Round terminal box/with lamp g indicator lamp, cont.
* With the 4G1 to 3 Series
( to ) AC
( to )
AC A B C
AC
( to )
( to )
Y
(±) SOL (±)
DC
DC
(±) A B C DC
(±)
-
The DC model has a surge suppressor Y * A type connector for DC only
+
SOL
* For W4G2 Series
* With the 4G1 to 3 Series (Single)

( )
d Compact terminal box/with lamp g With surge suppressor and indicator lamp
AC
( to ) COM
SOLa
( to ) A
AC ( to )
( ) AC AC (±) COM
( to ) DC SOLa
Red
(±) A
DC (±)
DC (Double)
(±)
( to ) B
* Grommet lead wire for DC only Black
SOLb

* For 4SO/4S1 AC ( to ) COM


b With surge suppressor e Round terminal box/basic (+) Red
SOLa
( to ) A

A B C (±)
B
(-) Black SOLb
Y DC (±) COM
* ‌Note that models with surge suppressor
SOL and lamp have polarity. SOLa
* Diode is used as a surge suppressor. A
(±)

Intro 71
For circuit diagrams of ○
a ,○
g , and ○
h , refer to the circuit diagrams of the following table.

Caution
Electrical connections (wiring method)
None :
Without lead wire I : With lead wire L : With indicator lamp
S : With surge suppressor N : Without socket
E type connector E type connector E type connector E type connector E type connector
32 I 33 N 34 With socket/terminal 35 I S L 36 N L S
Circuit diagram a Circuit diagram a Circuit diagram g Circuit diagram g
For AC voltages, the
● Lead wire length a dimension is 3.5 mm
300 mm longer than for DC
500 mm
1m voltages.
2m
3m

A type connector (downward) DIN terminal box EJ type connector with cover EJ type connector with cover Terminal block I/O connector
38 N 39 S L 40 I 41 I S L 42 L S 43 I S L
Circuit diagram g Circuit diagram h Circuit diagram a Circuit diagram h Circuit diagram g Circuit diagram g

2:B 1:COM

Unused 4:A
● ● ●
B COM A

I/O connector Individual wiring D-connector D* Individual wiring D-connector socket Individual wiring connector
45 I S L 46 I S L 47 None, with socket/terminal D* 48 with lead wire C I S L
Circuit diagram g I S L Circuit diagram g Circuit diagram g
* MN3E0/MN4E0 only * MN3E0/MN4E0 only ● Lead wire length
C : 300 mm
C0: 500 mm
C1:1000 mm
C2:2000 mm

2:B 1:COM(NPN)

3:COM(PNP) 4:A

DIN terminal box with Optional surge suppressor DIN terminal box with surge
h surge suppressor/lamp i attached (AC/DC) j suppressor/lamp
* With the MN4E Series * With the 4G Series Surge suppressor
(Single)
( to ) (Single)
( to ) AC included
a ( to ) Use a surge suppressor
(+, -)
AC when controlling the unit
R
Varistor
LED a Red with semiconductors. AC
sol ( to )
COM (+)
(-, +) DC Use a lead wire that is
(±) (-) 20/0.18.
(Double) Black With the DC model, only
DC Diode
the grommet lead wire is No.1 No.3 No.2
a SOL COM b SOL
a
(+, -)
(±) Diode has polarity. the suppression type in
LED
R the figure below.
a
5
23.
COM sol
(-, +) DC
16

b
b LED sol
(+, -) R
8

No.1 No.3 No.2

* For MN4S0 Series (Double)


a SOL COM b SOL

(Single)
a
(+, -)

R Power supply side AC


Varistor LED a
COM sol
Please - +
(-, +) be careful (Black) (Red)
Lead wire
(Double) Aluminum plate No.1 No.3 No.2
a SOL COM b SOL
a
for connection
(+, -) Diode
R
Varistor LED a
COM sol Lid
(-, +)
DC
Solenoid valve side
Varistor b
sol
The AC and DC/B types
b LED
(+, -) R have a varistor.
(There is no polarity.) No.1 No.3 No.2
a SOL COM b SOL

Intro 72
Intro 73

Das könnte Ihnen auch gefallen