Sie sind auf Seite 1von 12

Resistivity 2-D Survey

School : SK Sg. Siong


District : Sibu
Survey Date : 24th and 25th January 2010
Prepared by : Kevin Carradine ak Atet and Mohd Sazaly
Basarian
Checked by : 1. Mohd. Rizal Abd. Rashid
2. Khairul Rizzal Roslan

400m 200m 0m
Water
tank Toilet

Quarters
Dining hall

Classroom
Line 5

Classroom
400m 0m

Line 4
Tank 3
Line 2 ad
Tank 2 ro Football field
y Line 3

Quarters
ck
Pump house

Existing
ro
Tubewell
all
m
400m
S
0m Line 1

Quarters
Tank 1
Line 6
0m
Quarters 200m

School gate
Toilet
School gate

0m 200m
0m

Figure 1. SK. Sg. Siong survey layout plan


RESULT AND INTERPRETATION
SK SG. SIONG, SIBU
LINE 1: POLE DIPOLE LS ARRAY

Clayey sand
sand mixture

Figure 2: Pseudosection profile for Line 1

Figure 3: Pseudosection profile for Line 1 with topography.


This survey line was stretched 400 metres and cut across the football field of SK Sg. Siong. The surface is
mainly covered by clayey sand mixture. Underneath the football field shows high resistivity indicate sand
on the subsurface.
RESULTS AND INTERPRETATION
SK SG. SIONG, SIBU
LINE 2: POLE DIPOLE LS ARRAY

Saturated zone

Clayey sand

Figure 4: Pseudosection profile for Line 2.

Figure 5: Pseudosection profile for Line 2 with topography.


This survey line intersects with line 1 and parallel to the nearby river. Penetration depth is up to 140.7
metres. Clayey sand is found at depth 17.9 metres until 140.7 metres. Saturated zone is believed to get its
recharge from the nearby river.
RESULTS AND INTERPRETATION
SK SG. SIONG, SIBU
LINE 3: POLE DIPOLE S ARRAY
Intersect with Intersect with Intersect with
Line 5 Line 1 Line 6

Saturated zone
bedrock

Figure 6: Pseudosection profile for Line 3.

Figure 7: Pseudosection profile for Line 3 with topography.


This survey line intersects line 1, line 5 and line 6. Its penetration depth is up to 87.9 metres. From this
pseudosection, underneath this survey line is mostly clayey sand (dark blue to dark green in colour).

RESULTS AND INTERPRETATION


SK SG. SIONG, SIBU
LINE 4: POLE DIPOLE S ARRAY
Intersect with Intersect with Intersect with
Line 5 Line 1 Line 6

Saturated zone

Figure 8: Pseudosection profile for Line 4.

Figure 9: Pseudosection profile for Line 4 with topography.


This survey line intersects line 5, line 1 and line 6. Generally this area is covered by clay and sand mixture.

RESULTS AND INTERPRETATION


SK SG. SIONG, SIBU
LINE 5: POLE DIPOLE S ARRAY
Intersect with Intersect with
Line 2 Line 3

Saturated area

Figure 10: Pseudosection profile for Line 5.

Figure 11: Pseudosection profile for Line 5 with topography.


This survey line lies across the football field parallel to Line 1. Subsurface penetration is up to 77.5 metres.
Subsurface features here is mainly covered by clayey sand (light green to dark green in colour).
RESULTS AND INTERPRETATION
SK SG. SIONG, SIBU
LINE 6: POLE DIPOLE S ARRAY
Intersect with
Intersect with
Line 2
Line 3

Saturated zone

Figure 12: Pseudosection profile for Line 6.

Figure 13: Pseudosection profile for Line 6 with topography.


This survey line is set up parallel to the line 1 and line 5. Subsurface penetration is up to 87.9 metres and
its feature here is mainly covered by clayey sand (light green to dark green in colour). This line proves that
underneath school area have potential for fresh groundwater.
TUBEWELL PROPOSAL
SK SG. SIONG, SIBU
LINE 6: POLE DIPOLE S ARRAY

Proposed
Tubewell (PW1)
N 02°27.56.8’
E111°57.14.8’

Figure 14: Pseudosection profile for tubewell proposal at Line 6.

Proposed
Resistivit Water Type Depth of
Site Survey Line Tubewell (Along
y (Ωm) Posibilities Tubewell
Survey Line)
85 m
SK Sg. Siong, Line 6
10 - 120 Groundwater (fresh) N 02°27.56.8’ 40 m – 50 m
Sibu PDP4S
E111°57.14.8’
TUBEWELL PROPOSAL
SK SG. SIONG, SIBU
LINE 2: POLE DIPOLE LS ARRAY

Proposed
Tubewell (PW2)
N 02°27.55.6’
E 111°57.15.5’

Figure 15: Pseudosection profile for tubewell proposal at line 2.

Proposed
Resistivit Water Type Depth of
Site Survey Line Tubewell (Along
y (Ωm) Posibilities Tubewell
Survey Line)
217 m
SK Sg. Siong, Line 2
10 - 120 Groundwater (fresh) N 02°27.55.6’ 90 m – 100 m
Sibu PDP4LS
E 111°57.15.5’
TUBEWELL PROPOSAL
SK SG. SIONG, SIBU
LINE 3: POLE DIPOLE S ARRAY

Proposed
Tubewell (PW3)
N 02°27.56.2’
E 111°57.13.3’

Figure 16: Pseudosection profile for tubewell proposal at line 3.

Proposed
Resistivit Water Type Depth of
Site Survey Line Tubewell (Along
y (Ωm) Posibilities Tubewell
Survey Line)
115 m
SK Sg. Siong, Line 3
10 - 120 Groundwater (fresh) N 02°27.56.2’ 50 m – 60 m
Sibu PDP4S
E 111°57.13.3’

Interpretation:
All of this line provides a visible data in search for fresh groundwater. Resistivity value from 10Ωm to
120Ωm (blue colour to green colour) in pseudosection indicate there is fresh groundwater underneath.

Comment:
Existing tubewell cannot yield enough water since its screen pipe has collapsed. Proposed well is located
40 meters from existing tubewell.
SITE PHOTOS

School Signboard

Terrameter SAS4000 setup

Remote Cable Layout