The design wind loads are calculated in accordance with IS 875 (Part 3)
For Walls
Pressure on Wall due to external coefficient
Wind Angle A B C D
Case-1
Net Pressure on Wall (+Cpi)
Wind Angle A B C D
0 0.9 -0.05 -0.4 -0.4
90 -0.3 -0.3 0.9 0.1
Case-2
Net Pressure on Wall (-Cpi)
Wind Angle A B C D
0 0.5 -0.45 -0.8 -0.8
90 -0.7 -0.7 0.5 -0.3
For Roof
Pressure on Roof due to external coefficient
Wind Angle 0° Wind Angle 90°
Roof Angle EF GH EG FH
5 -0.9 -0.4 -0.8 -0.4
20 -0.4 -0.4 -0.7 -0.6
2.86 -0.971333 -0.4 -0.814267 -0.371467
Case-1
Net Pressure on Roof (+Cpi)
Wind Angle 0° Wind Angle 90°
Roof Angle EF GH EG FH
11.3 -0.771333 -0.2 -0.614267 -0.171467
Case-2
Net Pressure on Roof (-Cpi)
Wind Angle 0° Wind Angle 90°
Roof Angle EF GH EG FH
11.3 -1.171333 -0.6 -1.014267 -0.571467
Seismic Cofficient
Pz = 0.6 x Vz x Vz
Pd = k a x k d x P z