pump
curve number usgpm (L/s) ft (m) point (bep) motor hp odp tefc
N230202 VMS -10 0 2B 15 0 . 8 (9. 51) 97. 6 (2 9.7) 67. 6 0 % 2 — 5 6C
N 23 0 3 0 2 VMS -10 0 3 B 151 . 2 (9. 54) 147. 3 (4 4 .9) 67. 6 0 % 3 — 18 2TC
N 23 0 4 0 2 VMS -10 0 4B E 13 9.7 (8 . 81) 19 6 . 4 (59.9) 67. 6 0 % 3 — 18 4TC
N 23 0 5 0 2 VMS -10 0 5B 151 . 2 (9. 54) 24 5 . 5 (74 . 8) 67. 6 0 % 5 — 18 4TC
N 23 0 6 0 2 VMS -10 0 6B 14 5 .7 (9.19) 2 94 . 6 (8 9. 8) 67. 6 0 % 5 — 18 4TC
N 23 0 9 0 2 VMS -10 0 9 B 14 6 . 2 (9. 22) 4 4 4 . 4 (13 5 . 5) 67. 6 0 % 7. 5 18 4TC —
N 2312 0 2 VMS -1012B 14 6 . 6 (9. 2 5) 592 . 6 (18 0 . 6) 67. 6 0 % 10 — 215TC
N 2316 0 2 VMS -1016B 151 . 6 (9. 5 6) 79 0 .1 (24 0 . 8) 67. 6 0 % 15 215TC —
N 2 5 010 2 VMS -3 2 01 371 . 0 (2 3 . 41) 8 9. 4 (27. 2) 6 8 .70 % 5 — 18 4TC
N 2 5 0 222 VMS -3 2 0 2 -2 371 . 0 (2 3 . 41) 14 8 . 8 (4 5 . 4) 6 8 .70 % 7. 5 18 4TC —
N 2 5 0 3 22 VMS -3 2 0 3 -2 372 .1 (2 3 . 4 8) 2 37. 0 (72 . 2) 6 8 .70 % 10 — 215TC
N250432 VMS -3 2 0 4 -3 372 .1 (2 3 . 4 8) 314 . 6 (9 5 .9) 6 8 .70 % 15 215TC —
N250502 VMS -3 2 0 5 3 6 6 .1 (2 3 .10) 4 4 9.9 (137.1) 6 8 .70 % 20 — 2 5 6TC
N250602 VMS -3 2 0 6 370 . 6 (2 3 . 3 8) 54 6 .1 (16 6 . 5) 6 8 .70 % 25 — 2 8 4TSC
N 2 6 010 2 VMS - 4 5 01E 5 5 5 . 5 (3 5 . 0 5) 118 . 6 (3 6 .1) 8 3 .10 % 7. 5 — 215TC
N 2 6 0 212 VMS - 4 5 0 2 -1 5 59. 8 (3 5 . 3 2) 2 0 0 . 4 (61 .1) 8 3 .10 % 15 215TC —
N260302 VMS - 4 5 0 3 5 64 . 5 (3 5 . 61) 3 62 . 8 (110 . 6) 83.30% 25 — 2 8 4TSC
N 2 6 0 3 22 VMS - 4 5 0 3 -2 5 64 . 5 (3 5 . 61) 2 9 0 . 2 (8 8 . 5) 8 3 .10 % 20 — 2 5 6TC
N 2 6 0 412 VMS - 4 5 0 4 -1 5 64 . 5 (3 5 . 61) 4 51 . 3 (137. 6) 8 3 .10 % 30 — 2 8 6TSC
N 27010 2 VMS - 64 01E 78 5 . 2 (4 9. 54) 124 .7 (3 8 . 0) 8 4 .70 % 10 — 215TC
N 270 2 0 2 VMS - 64 0 2 811 .7 (51 . 21) 2 51 . 8 (76 .7) 8 4 .70 % 25 — 2 8 4TSC
N 270 212 VMS - 64 0 2 -1 811 .7 (51 . 21) 22 6 . 6 (69.1) 8 4 .70 % 20 — 2 5 6TC
N 270 3 22 VMS - 64 0 3 -2 811 .7 (51 . 21) 3 2 9. 2 (10 0 . 3) 8 4 .70 % 30 — 2 8 6TSC
N 2 8 010 2 VMS -15 01B 2 3 3 . 6 (14 .74) 6 3 . 8 (19. 4) 72 . 5 0 % 2 5 6C —
N280202 VMS -15 0 2B 23 4 . 5 (14 .79) 12 5 . 8 (3 8 . 3) 72 . 5 0 % 5 — 18 4TC
N280302 VMS -15 0 3 B E 2 3 5 . 2 (14 . 8 4) 18 9. 8 (57.9) 72 . 5 0 % 5 — 18 4TC
N280402 VMS -15 0 4B E 2 3 5 . 2 (14 . 8 4) 2 5 3 .1 (77.1) 72 . 5 0 % 7. 5 — 215TC
N280502 VMS -15 0 5B 2 3 3 . 8 (14 .75) 3 22 . 5 (9 8 . 3) 72 . 5 0 % 10 — 215TC
N 2 8 070 2 VMS -15 07B 2 3 5 . 2 (14 . 8 4) 4 42 .9 (13 5 . 0) 72 . 5 0 % 15 215TC —
N 2 810 0 2 VMS -1510 B 2 3 6 . 5 (14 .92) 6 3 9.9 (19 5 . 0) 72 . 5 0 % 20 — 2 5 6TC
N 2 812 0 2 VMS -1512B 2 3 6 . 5 (14 .92) 78 2 .9 (2 3 8 . 6) 72 . 5 0 % 25 — 2 8 4TSC
N 2 9 010 2 VMS -2 0 01B 2 67. 3 (16 . 8 6) 73 . 5 (22 . 4) 73 . 0 0 % 3 — 18 2TC
N290202 VMS -2 0 0 2B 2 62 . 6 (16 . 57) 14 3 . 5 (4 3 .7) 73 . 0 0 % 5 — 18 4TC
N290302 VMS -2 0 0 3 B 2 62 .7 (16 . 57) 216 . 5 (6 6 . 0) 73 . 0 0 % 7. 5 18 4TC —
Notes:
1 nsf 61 and nsf 372 certified complete package assembly.
2 Standard right hand connection orientation illustrated, please
indicate alternate connection orientation, if required.
3 All pumps are equal.
4 Standard grooved header connections.
Optional flanged ansi 150# or 300# connections available.
5 Optional tank shipped loose, installed by others.
Design envelope 6800 g submit ta l
2 duty pumps, Domestic water booster n230202 - n290302
Note: All dimensions are inches (mm), tolerances are (+/-) ½" (12 mm) unless otherwise specified.
su bmi tta l Design envelope 6800 g
n230202 - n290302 2 duty pumps, Domestic water booster
q [l/min]
0 50 100 150 200 250 300 400
280
900
p h h
[psi] [ft] vms 1016/15 hp vms 10b - 60 hz - 3450 rpm [m]
348 800 vms 1015/15 hp 240
vms 1014/15 hp
700
290
200
vms 1012/10 hp
600
vms 1011/10 hp
vms 1008/7.5 hp
174 400 120
vms 1007/7.5 hp
vms 1006/5 hp
300
116 vms 1005/5 hp 80
vms 1004/5 hp
200
vms 1003/3 hp
58 40
100 vms 1002/2 hp
vms 1001/1 hp
0 0 0
0 10 20 3 40 50 60 70 80 U.S.g.p.m.
0 2 4 6 8 10 12 14 16 18 20 q [m3/h]
80
1.5
% 60 [%]
p2 1
[hp] Single Impeller hp
0.5 40
0 20
0 10 20 3 40 50 60 70 80 U.S.g.p.m.
8
20
npsh npsh
[ft] 10 4 [m]
0 0
0 10 20 3 40 50 60 70 80 U.S.g.p.m.
note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
Design envelope 6800 g submit ta l
2 duty pumps, Domestic water booster n230202 - n290302
q [l/min]
0 100 200 300 400 500
280
900
p h h
vms 1512b/25hp [m]
[psi] [ft] vms 15b - 60 hz - 3500 rpm
348 800
vms 1511b/25hp 240
vms 1510b/20hp
700
290
200
vms 1509b/20hp
600
vms 1508b/20hp
232 160
500 vms 1507b/15hp
vms 1506b/15hp
174 400 120
vms 1505b/10hp
300
vms 1504b/10hp
116 80
vms 1503b/7.5hp
200
vms 1502b/5hp
58 40
100
vms 1501b/2hp
0 0 0
0 20 40 60 80 100 120 U.S.g.p.m.
0 5 10 15 20 25 q [m3/h]
80
2.5
%
60 [%]
p2 2
[hp]
1.5 40
Single impeller hp
1 20
0 20 40 60 80 100 120 U.S.g.p.m.
8
20
npsh 4
npsh
[ft] 10 [m]
0 0
0 20 40 60 80 100 120 U.S.g.p.m.
note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
su bmi tta l Design envelope 6800 g
n230202 - n290302 2 duty pumps, Domestic water booster
q [l/min]
0 100 200 300 400 500 600
280
900
p h h
[psi] [ft] vms 20b - 60 hz - 3450 rpm [m]
348 800 vms 2010/25 hp
240
vms 2009/25 hp
700
290
vms 2008/20 hp
200
600
vms 2007/20 hp
232 160
500
vms 2006/15 hp
vms 2004/10 hp
300
116 80
vms 2003/7.5 hp
200
vms 2002/5 hp
58 40
100 vms 2001/3 hp
0 0 0
0 20 40 60 80 100 120 140 U.S.g.p.m.
40q [m /h]
3
0 5 10 15 20 25 30
3 80
%
60 [%]
p2 2.5
[hp]
2 40
Single Impeller hp
1.5 20
0 20 40 60 80 100 120 140 U.S.g.p.m.
12
30
npsh 8 npsh
20
[ft] 4
[m]
10
0 0
0 20 40 60 80 100 120 140 U.S.g.p.m.
note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
Design envelope 6800 g submit ta l
2 duty pumps, Domestic water booster n230202 - n290302
335 1100
H H
(m) (ft) vms 32 - 60 hz - 3500 rpm
304 1000 vms 3210-1
min. flow
244 800
vms 3208-3
vms 3207
213 700
vms 3206
183 600
vms 3205
152 500
122 400 20 6
vms 3204-3
vms 3203
91 300 15 4.5
nsph(m)
nsph(ft)
vms 3203-2
vms 3201
30 100 5 1.5
npsh
0 0 0 0
0 20 40 60 80 100 120 140 160 180 200
us gpm
0 5 9 14 18 23 27 32 36 41 45
q m3/h
80
70
60
50
eff.% 40
30
20
10
0
0 20 40 60 80 100 120 140 160 180 200
us gpm
note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
su bmi tta l Design envelope 6800 g
n230202 - n290302 2 duty pumps, Domestic water booster
274 900
H H
(m) (ft)
vms 4507-2 vms 45 - 60 hz - 3500 rpm
244 800 min. flow
vms 4506
213 700
vms 4505
183 600
152 500
vms 4504-1
122 400 20 6
vms 4503
vms 4503-2
91 300 15 4.5
nsph(m)
nsph(ft)
vms 4502-1
61 200 10 3
0 0 0 0
0 50 100 150 200 250 300
us gpm
0 11 13 34 45 57 68
q m3/h
90
80
70
60
eff.% 50
40
30
20
10
0
0 50 100 150 200 250 300
us gpm
note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
Design envelope 6800 g submit ta l
2 duty pumps, Domestic water booster n230202 - n290302
183 600
H H vms 64 - 60 hz - 3500 rpm
(m) (ft) vms 6404 min. flow
vms 6403
122 400
vms 6403-2
91 300
vms 6402
vms 6402-1
61 200 20 6
vms 6401
15 4.5
nsph(m)
nsph(ft)
vms 6401-1
30 100 10 3
5 1.5
npsh
0 0 0 0
0 50 100 150 200 250 300 350 400 450
us gpm
0 11 13 34 45 57 68 80 91 102
q m /h 3
90
80
70
60
eff.% 50
40
30
20
10
note: Pump curves are shown for information purpose only and should not be used for selection. Individual pump curves don’t represent the performance of a complete package
as they ignore losses and control constraints. Please refer to Curves and diagrams on Armstrong’s website for a detailed performance envelope for the specific booster model.
su bmi tta l Design envelope 6800 g
n230202 - n290302 2 duty pumps, Domestic water booster
10
4 11 2 6 discharge
connection
grooved
3 j1 standard
b
c max
f
8 7
5
9
j
d
suction
g a connection
h 1 grooved
10 e standard
item description
manchester
+44 (0) 8444 145 145
bangalore
+91 (0) 80 4906 3555
shanghai
+86 21 3756 6696
a r m s t r o n g f lu i d t e c h n o lo g y
são paulo established 1934 a r m s t r o n g f lu i d t e c h n o lo g y. c o m
+55 11 4785 1330