EL ETIHAD STEEL FACTORY

Inq #: RFQ-18-162
Client: AL Seal
Project: Shield 5 Program
Scope of Work: Fabrication, Supply and Delivery & Installation of Structural Stee ACTUAL ACTUAL
Issued Date & Version: June 5, 2018 For Steel Quantity: For Painting Purposes:
Length Qty Unit Weight
Item Total Length Surface Area Total Area
No Description Profile Material Grade (m) (nos) (kg/m) Total Weight (kg) (m) (m2/m) (m2) Remarks
1 Column RHS 150x100x8 S355 1.80 48 28.90 2,496.96 86.40 0.48 41.39 Facility - 104
2 Beams - B1 RHS 150x100x8 S355 4.50 44 28.90 5,722.20 198.00 0.48 94.84 Facility - 104
3 Beams - B1 RHS 150x100x8 S355 3.00 40 28.90 3,468.00 120.00 0.48 57.48 Facility - 104
4 Beams - B1 RHS 150x100x8 S355 1.50 40 28.90 1,734.00 60.00 0.48 28.74 Facility - 104
5 Beams - B2 RHS 150x100x8 S355 4.50 8 28.90 1,040.40 36.00 0.48 17.24 Facility - 104
6 Beams - B2 RHS 150x100x8 S355 3.00 20 28.90 1,734.00 60.00 0.48 28.74 Facility - 104
7 Steel Tee T 150x75x12 S355 1.60 100 11.50 1,840.00 160.00 0.45 71.20 Facility - 104
8 Angle @Col. L 75x75x8 S235 1.60 48 9.00 691.20 76.80 0.29 22.43 Facility - 104
9 Angle Conn. @ Tee L 75x75x6 S235 0.05 400 6.87 137.40 20.00 0.29 5.84 Facility - 104
10 Angle Conn. @ B2 L 75x75x10 S235 0.08 56 11.10 46.62 4.20 0.29 1.23 Facility - 104
11 Angle Conn. @ B1 L 65x65x6 S235 0.10 192 5.91 113.47 19.20 0.26 4.90 Facility - 104
12 Allowance for fittings (15%) S235 -- -- -- 2,853.64 -- -- 56.10 Facility - 104
13 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 139.20 m2 -- -- -- -- Facility - 104
14 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 120.00 Lm -- -- -- -- Facility - 104
15 Column SHS 100x100x8 S355 1.80 36 22.60 1,464.48 64.80 0.38 24.56 Facility - 105
16 Beams - B1 RHS 150x100x8 S355 3.00 64 28.90 5,548.80 192.00 0.48 91.97 Facility - 105
17 Beams - B1 RHS 150x100x8 S355 1.50 32 28.90 1,387.20 48.00 0.48 22.99 Facility - 105
18 Beams - B2 RHS 150x100x8 S355 3.00 24 28.90 2,080.80 72.00 0.48 34.49 Facility - 105
19 Steel Tee T 150x75x12 S355 1.60 72 11.50 1,324.80 115.20 0.45 51.26 Facility - 105
20 Angle @Col. L 75x75x8 S235 1.60 36 9.00 518.40 57.60 0.29 16.82 Facility - 105
21 Angle Conn. @ Tee L 75x75x6 S235 0.05 288 6.87 98.93 14.40 0.29 4.20 Facility - 105
22 Angle Conn. @ B2 L 75x75x10 S235 0.08 48 11.10 39.96 3.60 0.29 1.05 Facility - 105
23 Angle Conn. @ B1 L 65x65x6 S235 0.10 160 5.91 94.56 16.00 0.26 4.08 Facility - 105
24 Allowance for fittings (15%) S235 -- -- -- 1,883.69 -- -- 37.71 Facility - 105
25 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 104.40 m2 -- -- -- -- Facility - 105
26 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 48.00 Lm -- -- -- -- Facility - 105
27 Column RHS 150x100x8 S355 1.80 20 28.90 1,040.40 36.00 0.48 17.24 Facility - 109
28 Beams - B1 RHS 150x100x8 S355 4.50 15 28.90 1,950.75 67.50 0.48 32.33 Facility - 109
29 Beams - B1 RHS 150x100x8 S355 3.00 10 28.90 867.00 30.00 0.48 14.37 Facility - 109
30 Beams - B1 RHS 150x100x8 S355 1.50 10 28.90 433.50 15.00 0.48 7.19 Facility - 109
31 Beams - B2 RHS 150x100x8 S355 4.50 5 28.90 650.25 22.50 0.48 10.78 Facility - 109
32 Beams - B2 RHS 150x100x8 S355 3.00 10 28.90 867.00 30.00 0.48 14.37 Facility - 109
33 Steel Tee T 150x75x12 S355 1.60 55 11.50 1,012.00 88.00 0.45 39.16 Facility - 109
34 Angle @Col. L 75x75x8 S235 1.60 20 9.00 288.00 32.00 0.29 9.34 Facility - 109
35 Angle Conn. @ Tee L 75x75x6 S235 0.05 220 6.87 75.57 11.00 0.29 3.21 Facility - 109
36 Angle Conn. @ B2 L 75x75x10 S235 0.08 30 11.10 24.98 2.25 0.29 0.66 Facility - 109
37 Angle Conn. @ B1 L 65x65x6 S235 0.10 80 5.91 47.28 8.00 0.26 2.04 Facility - 109
38 Allowance for fittings (15%) S235 -- -- -- 1,088.51 -- -- 22.60 Facility - 109
39 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 76.13 m2 -- -- -- -- Facility - 109
40 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 30.00 Lm -- -- -- -- Facility - 109
41 Column SHS 100x100x8 S355 1.80 24 22.60 976.32 43.20 0.38 16.37 Facility - 203A
42 Beams - B1 RHS 150x100x8 S355 3.00 36 28.90 3,121.20 108.00 0.48 51.73 Facility - 203A
43 Beams - B1 RHS 150x100x8 S355 1.50 16 28.90 693.60 24.00 0.48 11.50 Facility - 203A
44 Beams - B2 RHS 150x100x8 S355 3.00 16 28.90 1,387.20 48.00 0.48 22.99 Facility - 203A
45 Steel Tee T 150x75x12 S355 1.60 48 11.50 883.20 76.80 0.45 34.18 Facility - 203A
46 Angle @Col. L 75x75x8 S235 1.60 24 9.00 345.60 38.40 0.29 11.21 Facility - 203A
47 Angle Conn. @ Tee L 75x75x6 S235 0.05 192 6.87 65.95 9.60 0.29 2.80 Facility - 203A
48 Angle Conn. @ B2 L 75x75x10 S235 0.08 32 11.10 26.64 2.40 0.29 0.70 Facility - 203A
49 Angle Conn. @ B1 L 65x65x6 S235 0.10 96 5.91 56.74 9.60 0.26 2.45 Facility - 203A
50 Allowance for fittings (15%) S235 -- -- -- 1,133.47 -- -- 23.09 Facility - 203A
51 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 69.60 m2 -- -- -- -- Facility - 203A
52 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 48.00 Lm -- -- -- -- Facility - 203A
53 Column SHS 100x100x8 S355 1.80 24 22.60 976.32 43.20 0.38 16.37 Facility - 203B
54 Beams - B1 RHS 150x100x8 S355 3.00 36 28.90 3,121.20 108.00 0.48 51.73 Facility - 203B
55 Beams - B1 RHS 150x100x8 S355 1.50 16 28.90 693.60 24.00 0.48 11.50 Facility - 203B
56 Beams - B2 RHS 150x100x8 S355 3.00 16 28.90 1,387.20 48.00 0.48 22.99 Facility - 203B
57 Steel Tee T 150x75x12 S355 1.60 48 11.50 883.20 76.80 0.45 34.18 Facility - 203B
58 Angle @Col. L 75x75x8 S235 1.60 24 9.00 345.60 38.40 0.29 11.21 Facility - 203B
59 Angle Conn. @ Tee L 75x75x6 S235 0.05 192 6.87 65.95 9.60 0.29 2.80 Facility - 203B
60 Angle Conn. @ B2 L 75x75x10 S235 0.08 32 11.10 26.64 2.40 0.29 0.70 Facility - 203B
61 Angle Conn. @ B1 L 65x65x6 S235 0.10 96 5.91 56.74 9.60 0.26 2.45 Facility - 203B
62 Allowance for fittings (15%) S235 -- -- -- 1,133.47 -- -- 23.09 Facility - 203B
63 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 69.60 m2 -- -- -- -- Facility - 203B
64 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 48.00 Lm -- -- -- -- Facility - 203B
65 Column RHS 150x100x8 S355 3.00 56 28.90 4,855.20 168.00 0.48 80.47 Facility - 301
66 Beams - B1 RHS 150x100x8 S355 3.00 48 28.90 4,161.60 144.00 0.48 68.98 Facility - 301
67 Beams - B1 RHS 150x100x8 S355 4.50 52 28.90 6,762.60 234.00 0.48 112.09 Facility - 301
68 Beams - B1 RHS 150x100x8 S355 1.50 48 28.90 2,080.80 72.00 0.48 34.49 Facility - 301
69 Beams - B2 RHS 150x100x8 S355 3.00 44 28.90 3,814.80 132.00 0.48 63.23 Facility - 301
70 Beams - B2 RHS 150x100x8 S355 4.50 8 28.90 1,040.40 36.00 0.48 17.24 Facility - 301
71 Steel Tee T 150x75x12 S355 2.30 172 11.50 4,549.40 395.60 0.45 176.04 Facility - 301
72 Angle @Col. L 75x75x8 S235 2.30 56 9.00 1,159.20 128.80 0.29 37.61 Facility - 301
73 Angle Conn. @ Tee L 75x75x6 S235 0.05 688 6.87 236.33 34.40 0.29 10.04 Facility - 301
74 Angle Conn. @ B2 L 75x75x10 S235 0.08 104 11.10 86.58 7.80 0.29 2.28 Facility - 301
75 Angle Conn. @ B1 L 65x65x6 S235 0.10 320 5.91 189.12 32.00 0.26 8.16 Facility - 301
76 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 361.20 m2 -- -- -- -- Facility - 301
77 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 132.00 Lm -- -- -- -- Facility - 301
78 Column RHS 150x100x8 S355 3.00 16 28.90 1,387.20 48.00 0.48 22.99 Facility - 301
79 Beams - B1 RHS 150x100x8 S355 4.50 8 28.90 1,040.40 36.00 0.48 17.24 Facility - 301

496796876.xlsx Page 1
EL ETIHAD STEEL FACTORY
Inq #: RFQ-18-162
Client: AL Seal
Project: Shield 5 Program
Scope of Work: Fabrication, Supply and Delivery & Installation of Structural Stee ACTUAL ACTUAL
Issued Date & Version: June 5, 2018 For Steel Quantity: For Painting Purposes:
Length Qty Unit Weight
Item Total Length Surface Area Total Area
No Description Profile Material Grade (m) (nos) (kg/m) Total Weight (kg) (m) (m2/m) (m2) Remarks
80 Beams - B1 RHS 150x100x8 S355 2.25 8 28.90 520.20 18.00 0.48 8.62 Facility - 301
81 Beams - B1 RHS 150x100x8 S355 3.00 12 28.90 1,040.40 36.00 0.48 17.24 Facility - 301
82 Angle Conn. @ B1 L 65x65x6 S235 0.10 64 5.91 37.82 6.40 0.26 1.63 Facility - 301
83 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 24.00 Lm -- -- -- -- Facility - 301
84 Column RHS 150x100x8 S355 3.00 16 28.90 1,387.20 48.00 0.48 22.99 Facility - 301
85 Beams - B1 RHS 150x100x8 S355 3.00 20 28.90 1,734.00 60.00 0.48 28.74 Facility - 301
86 Beams - B1 RHS 150x100x8 S355 1.50 8 28.90 346.80 12.00 0.48 5.75 Facility - 301
87 Angle Conn. @ B1 L 65x65x6 S235 0.10 64 5.91 37.82 6.40 0.26 1.63 Facility - 301
88 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 24.00 Lm -- -- -- -- Facility - 301
89 Allowance for fittings (15%) S235 -- -- -- 5,470.18 -- -- 110.62 Facility - 301
90 Column RHS 150x100x10 S355 3.00 63 35.30 6,671.70 189.00 0.47 89.59 Facility - 303
91 Beams - B1 RHS 150x100x8 S355 3.00 132 28.90 11,444.40 396.00 0.48 189.68 Facility - 303
92 Beams - B1 RHS 150x100x8 S355 1.50 72 28.90 3,121.20 108.00 0.48 51.73 Facility - 303
93 Beams - B2 RHS 150x100x8 S355 3.00 30 28.90 2,601.00 90.00 0.48 43.11 Facility - 303
94 Steel Tee T 150x75x12 S355 2.30 90 11.50 2,380.50 207.00 0.45 92.12 Facility - 303
95 Angle @Col. L 75x75x8 S235 2.30 63 9.00 1,304.10 144.90 0.29 42.31 Facility - 303
96 Angle Conn. @ Tee L 75x75x6 S235 0.05 360 6.87 123.66 18.00 0.29 5.26 Facility - 303
97 Angle Conn. @ B2 L 75x75x10 S235 0.08 60 11.10 49.95 4.50 0.29 1.31 Facility - 303
98 Angle Conn. @ B1 L 65x65x6 S235 0.10 312 5.91 184.39 31.20 0.26 7.96 Facility - 303
99 Allowance for fittings (15%) S235 -- -- -- 4,182.14 -- -- 78.46 Facility - 303
100 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 193.50 m2 -- -- -- -- Facility - 303
101 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 108.00 Lm -- -- -- -- Facility - 303
102 Column RHS 150x100x10 S355 3.00 64 35.30 6,777.60 192.00 0.47 91.01 Facility - 304
103 Beams - B1 RHS 150x100x8 S355 4.50 57 28.90 7,412.85 256.50 0.48 122.86 Facility - 304
104 Beams - B1 RHS 150x100x8 S355 3.00 50 28.90 4,335.00 150.00 0.48 71.85 Facility - 304
105 Beams - B1 RHS 150x100x8 S355 1.50 50 28.90 2,167.50 75.00 0.48 35.93 Facility - 304
106 Beams - B2 RHS 150x100x8 S355 4.50 11 28.90 1,430.55 49.50 0.48 23.71 Facility - 304
107 Beams - B2 RHS 150x100x8 S355 3.00 17 28.90 1,473.90 51.00 0.48 24.43 Facility - 304
108 Steel Tee T 150x75x12 S355 2.30 106 11.50 2,803.70 243.80 0.45 108.49 Facility - 304
109 Angle @Col. L 75x75x8 S235 2.30 64 9.00 1,324.80 147.20 0.29 42.98 Facility - 304
110 Angle Conn. @ Tee L 75x75x6 S235 0.05 424 6.87 145.64 21.20 0.29 6.19 Facility - 304
111 Angle Conn. @ B2 L 75x75x10 S235 0.08 56 11.10 46.62 4.20 0.29 1.23 Facility - 304
112 Angle Conn. @ B1 L 65x65x6 S235 0.10 328 5.91 193.85 32.80 0.26 8.36 Facility - 304
113 Allowance for fittings (15%) S235 -- -- -- 4,216.80 -- -- 80.56 Facility - 304
114 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 216.08 m2 -- -- -- -- Facility - 304
115 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 150.00 Lm -- -- -- -- Facility - 304
116 Column RHS 150x100x10 S355 3.00 108 35.30 11,437.20 324.00 0.47 153.58 Facility - 308
117 Beams - B1 RHS 150x100x8 S355 4.50 96 28.90 12,484.80 432.00 0.48 206.93 Facility - 308
118 Beams - B1 RHS 150x100x8 S355 3.00 84 28.90 7,282.80 252.00 0.48 120.71 Facility - 308
119 Beams - B1 RHS 150x100x8 S355 1.50 84 28.90 3,641.40 126.00 0.48 60.35 Facility - 308
120 Beams - B2 RHS 150x100x8 S355 4.50 18 28.90 2,340.90 81.00 0.48 38.80 Facility - 308
121 Beams - B2 RHS 150x100x8 S355 3.00 42 28.90 3,641.40 126.00 0.48 60.35 Facility - 308
122 Steel Tee T 150x75x12 S355 2.30 216 11.50 5,713.20 496.80 0.45 221.08 Facility - 308
123 Angle @Col. L 75x75x8 S235 2.30 108 9.00 2,235.60 248.40 0.29 72.53 Facility - 308
124 Angle Conn. @ Tee L 75x75x6 S235 0.05 864 6.87 296.78 43.20 0.29 12.61 Facility - 308
125 Angle Conn. @ B2 L 75x75x10 S235 0.08 120 11.10 99.90 9.00 0.29 2.63 Facility - 308
126 Angle Conn. @ B1 L 65x65x6 S235 0.10 504 5.91 297.86 50.40 0.26 12.85 Facility - 308
127 Allowance for fittings (15%) S235 -- -- -- 7,420.78 -- -- 144.36 Facility - 308
128 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 445.05 m2 -- -- -- -- Facility - 308
129 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 252.00 Lm -- -- -- -- Facility - 308
130 Column SHS 100x100x8 S355 1.80 48 22.60 1,952.64 86.40 0.38 32.75 Facility - 311
131 Beams - B1 RHS 150x100x8 S355 3.00 92 28.90 7,976.40 276.00 0.48 132.20 Facility - 311
132 Beams - B1 RHS 150x100x8 S355 1.50 48 28.90 2,080.80 72.00 0.48 34.49 Facility - 311
133 Beams - B2 RHS 150x100x8 S355 3.00 28 28.90 2,427.60 84.00 0.48 40.24 Facility - 311
134 Steel Tee T 150x75x12 S355 1.60 84 11.50 1,545.60 134.40 0.45 59.81 Facility - 311
135 Angle @Col. L 75x75x8 S235 1.60 48 9.00 691.20 76.80 0.29 22.43 Facility - 311
136 Angle Conn. @ Tee L 75x75x6 S235 0.05 336 6.87 115.42 16.80 0.29 4.91 Facility - 311
137 Angle Conn. @ B2 L 75x75x10 S235 0.08 56 11.10 46.62 4.20 0.29 1.23 Facility - 311
138 Angle Conn. @ B1 L 65x65x6 S235 0.10 272 5.91 160.75 27.20 0.26 6.94 Facility - 311
139 Allowance for fittings (15%) S235 -- -- -- 2,549.55 -- -- 50.25 Facility - 311
140 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 121.80 m2 -- -- -- -- Facility - 311
141 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 72.00 Lm -- -- -- -- Facility - 311
142 Column SHS 100x100x8 S355 1.80 12 22.60 488.16 21.60 0.38 8.19 Facility - 315
143 Beams - B1 RHS 150x100x8 S355 3.00 18 28.90 1,560.60 54.00 0.48 25.87 Facility - 315
144 Beams - B1 RHS 150x100x8 S355 1.50 8 28.90 346.80 12.00 0.48 5.75 Facility - 315
145 Beams - B2 RHS 150x100x8 S355 3.00 8 28.90 693.60 24.00 0.48 11.50 Facility - 315
146 Steel Tee T 150x75x12 S355 1.60 24 11.50 441.60 38.40 0.45 17.09 Facility - 315
147 Angle @Col. L 75x75x8 S235 1.60 12 9.00 172.80 19.20 0.29 5.61 Facility - 315
148 Angle Conn. @ Tee L 75x75x6 S235 0.05 96 6.87 32.98 4.80 0.29 1.40 Facility - 315
149 Angle Conn. @ B2 L 75x75x10 S235 0.08 16 11.10 13.32 1.20 0.29 0.35 Facility - 315
150 Angle Conn. @ B1 L 65x65x6 S235 0.10 56 5.91 33.10 5.60 0.26 1.43 Facility - 315
151 Allowance for fittings (15%) S235 -- -- -- 567.44 -- -- 11.58 Facility - 315
152 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 34.80 m2 -- -- -- -- Facility - 315
153 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 24.00 Lm -- -- -- -- Facility - 315
154 Column RHS 150x100x10 S355 3.00 66 35.30 6,989.40 198.00 0.47 93.85 Facility - 401
155 Beams - B1 RHS 150x100x8 S355 4.50 57 28.90 7,412.85 256.50 0.48 122.86 Facility - 401
156 Beams - B1 RHS 150x100x8 S355 3.00 48 28.90 4,161.60 144.00 0.48 68.98 Facility - 401
157 Beams - B1 RHS 150x100x8 S355 1.50 48 28.90 2,080.80 72.00 0.48 34.49 Facility - 401
158 Beams - B2 RHS 150x100x8 S355 4.50 18 28.90 2,340.90 81.00 0.48 38.80 Facility - 401
159 Beams - B2 RHS 150x100x8 S355 3.00 24 28.90 2,080.80 72.00 0.48 34.49 Facility - 401
160 Steel Tee T 150x75x12 S355 2.30 162 11.50 4,284.90 372.60 0.45 165.81 Facility - 401

496796876.xlsx Page 2
EL ETIHAD STEEL FACTORY
Inq #: RFQ-18-162
Client: AL Seal
Project: Shield 5 Program
Scope of Work: Fabrication, Supply and Delivery & Installation of Structural Stee ACTUAL ACTUAL
Issued Date & Version: June 5, 2018 For Steel Quantity: For Painting Purposes:
Length Qty Unit Weight
Item Total Length Surface Area Total Area
No Description Profile Material Grade (m) (nos) (kg/m) Total Weight (kg) (m) (m2/m) (m2) Remarks
161 Angle @Col. L 75x75x8 S235 2.30 66 9.00 1,366.20 151.80 0.29 44.33 Facility - 401
162 Angle Conn. @ Tee L 75x75x6 S235 0.05 648 6.87 222.59 32.40 0.29 9.46 Facility - 401
163 Angle Conn. @ B2 L 75x75x10 S235 0.08 84 11.10 69.93 6.30 0.29 1.84 Facility - 401
164 Angle Conn. @ B1 L 65x65x6 S235 0.10 324 5.91 191.48 32.40 0.26 8.26 Facility - 401
165 Allowance for fittings (15%) S235 -- -- -- 4,680.22 -- -- 93.47 Facility - 401
166 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 328.95 m2 -- -- -- -- Facility - 401
167 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 144.00 Lm -- -- -- -- Facility - 401
168 Column SHS 100x100x8 S355 1.80 30 22.60 1,220.40 54.00 0.38 20.47 Facility - 403
169 Beams - B1 RHS 150x100x8 S355 3.00 54 28.90 4,681.80 162.00 0.48 77.60 Facility - 403
170 Beams - B1 RHS 150x100x8 S355 1.50 26 28.90 1,127.10 39.00 0.48 18.68 Facility - 403
171 Beams - B2 RHS 150x100x8 S355 3.00 17 28.90 1,473.90 51.00 0.48 24.43 Facility - 403
172 Steel Tee T 150x75x12 S355 1.60 51 11.50 938.40 81.60 0.45 36.31 Facility - 403
173 Angle @Col. L 75x75x8 S235 1.60 30 9.00 432.00 48.00 0.29 14.02 Facility - 403
174 Angle Conn. @ Tee L 75x75x6 S235 0.05 204 6.87 70.07 10.20 0.29 2.98 Facility - 403
175 Angle Conn. @ B2 L 75x75x10 S235 0.08 34 11.10 28.31 2.55 0.29 0.74 Facility - 403
176 Angle Conn. @ B1 L 65x65x6 S235 0.10 164 5.91 96.92 16.40 0.26 4.18 Facility - 403
177 Allowance for fittings (15%) S235 -- -- -- 1,510.34 -- -- 29.91 Facility - 403
178 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 73.95 m2 -- -- -- -- Facility - 403
179 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 78.00 Lm -- -- -- -- Facility - 403
180 Column RHS 150x100x8 S355 1.80 8 28.90 416.16 14.40 0.48 6.90 Facility - 405
181 Beams - B1 RHS 150x100x8 S355 4.50 7 28.90 910.35 31.50 0.48 15.09 Facility - 405
182 Beams - B1 RHS 150x100x8 S355 3.00 6 28.90 520.20 18.00 0.48 8.62 Facility - 405
183 Beams - B1 RHS 150x100x8 S355 1.50 6 28.90 260.10 9.00 0.48 4.31 Facility - 405
184 Beams - B2 RHS 150x100x8 S355 4.50 2 28.90 260.10 9.00 0.48 4.31 Facility - 405
185 Beams - B2 RHS 150x100x8 S355 3.00 3 28.90 260.10 9.00 0.48 4.31 Facility - 405
186 Steel Tee T 150x75x12 S355 1.60 19 11.50 349.60 30.40 0.45 13.53 Facility - 405
187 Angle @Col. L 75x75x8 S235 1.60 8 9.00 115.20 12.80 0.29 3.74 Facility - 405
188 Angle Conn. @ Tee L 75x75x6 S235 0.05 76 6.87 26.11 3.80 0.29 1.11 Facility - 405
189 Angle Conn. @ B2 L 75x75x10 S235 0.08 10 11.10 8.33 0.75 0.29 0.22 Facility - 405
190 Angle Conn. @ B1 L 65x65x6 S235 0.10 40 5.91 23.64 4.00 0.26 1.02 Facility - 405
191 Allowance for fittings (15%) S235 -- -- -- 472.48 -- -- 9.47 Facility - 405
192 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 26.10 m2 -- -- -- -- Facility - 405
193 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 18.00 Lm -- -- -- -- Facility - 405
194 Column SHS 100x100x8 S355 1.80 14 22.60 569.52 25.20 0.38 9.55 Facility - 501
195 Beams - B1 RHS 150x100x8 S355 3.00 13 28.90 1,127.10 39.00 0.48 18.68 Facility - 501
196 Beams - B1 RHS 150x100x8 S355 1.50 6 28.90 260.10 9.00 0.48 4.31 Facility - 501
197 Beams - B2 RHS 150x100x8 S355 3.00 5 28.90 433.50 15.00 0.48 7.19 Facility - 501
198 Beams - B3 RHS 150x100x8 S355 3.00 9 28.90 780.30 27.00 0.48 12.93 Facility - 501
199 Beams - B3 RHS 150x100x8 S355 1.50 4 28.90 173.40 6.00 0.48 2.87 Facility - 501
200 Beams - B4 RHS 150x100x8 S355 3.00 4 28.90 346.80 12.00 0.48 5.75 Facility - 501
201 Steel Tee T 150x75x12 S355 1.60 27 11.50 496.80 43.20 0.45 19.22 Facility - 501
202 Angle @Col. L 75x75x8 S235 1.60 14 9.00 201.60 22.40 0.29 6.54 Facility - 501
203 Angle Conn. @ Tee L 75x75x6 S235 0.05 108 6.87 37.10 5.40 0.29 1.58 Facility - 501
204 Angle Conn. @ B2,B4 L 75x75x10 S235 0.08 18 11.10 14.99 1.35 0.29 0.39 Facility - 501
205 Angle Conn. @ B1,B3 L 65x65x6 S235 0.10 60 5.91 35.46 6.00 0.26 1.53 Facility - 501
206 Allowance for fittings (15%) S235 -- -- -- 671.50 -- -- 13.58 Facility - 501
207 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 39.15 m2 -- -- -- -- Facility - 501
208 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 30.00 Lm -- -- -- -- Facility - 501
209 Column SHS 100x100x8 S355 1.80 42 22.60 1,708.56 75.60 0.38 28.65 Facility - 503
210 Beams - B1 RHS 150x100x8 S355 3.00 27 28.90 2,340.90 81.00 0.48 38.80 Facility - 503
211 Beams - B1 RHS 150x100x8 S355 1.50 12 28.90 520.20 18.00 0.48 8.62 Facility - 503
212 Beams - B2 RHS 150x100x8 S355 3.00 12 28.90 1,040.40 36.00 0.48 17.24 Facility - 503
213 Beams - B3 RHS 150x100x8 S355 3.00 39 28.90 3,381.30 117.00 0.48 56.04 Facility - 503
214 Beams - B3 RHS 150x100x8 S355 1.50 18 28.90 780.30 27.00 0.48 12.93 Facility - 503
215 Beams - B4 RHS 150x100x8 S355 3.00 15 28.90 1,300.50 45.00 0.48 21.56 Facility - 503
216 Steel Tee T 150x75x12 S355 1.60 81 11.50 1,490.40 129.60 0.45 57.67 Facility - 503
217 Angle @Col. L 75x75x8 S235 1.60 42 9.00 604.80 67.20 0.29 19.62 Facility - 503
218 Angle Conn. @ Tee L 75x75x6 S235 0.05 324 6.87 111.29 16.20 0.29 4.73 Facility - 503
219 Angle Conn. @ B2,B4 L 75x75x10 S235 0.08 54 11.10 44.96 4.05 0.29 1.18 Facility - 503
220 Angle Conn. @ B1,B3 L 65x65x6 S235 0.10 192 5.91 113.47 19.20 0.26 4.90 Facility - 503
221 Allowance for fittings (15%) S235 -- -- -- 2,015.56 -- -- 40.79 Facility - 503
222 Vertical Steel Screen Panel (perforated screen, 700x700xmm, HDG, S235) -- 39.15 m2 -- -- -- -- Facility - 503
223 Horizontal Sunshade Panel, Pre-engineered Aluminum Panel, 2.4 kPa -- 30.00 Lm -- -- -- -- Facility - 503

TOTAL: 320,848.16 12,574.85 6,330.03

496796876.xlsx Page 3
**split from UC section ( T 152x76x12 = 152.2x76.1x5.8x6.8)

***metal roof deck EXCLUDED. No detail.

496796876.xlsx Page 4
EL ETIHAD STEEL FACTORY
Inq #: RFQ-18-162
Client: AL Seal
Project: Shield 5 Program
Scope of Work: Fabrication, Supply and Delivery & Installation of Structural Stee ACTUAL With Wastage
Issued Date & Version: June 5, 2018 For Steel Quantity: For Steel Quantity:
Length Unit Weight Quantity ± 5 %
Item Qty Total Length Supply Length Total Weight
No Description Profile Material Grade (m) (nos) (kg/m) Total Weight (kg) (m) (m) (nos) (kg) Allowance (%)
1 Column RHS 150x100x10 S355 3.00 301 35.30 31,875.90 903.00 12.00 80.00 33,888.00 6%
2 Column RHS 150x100x8 S355 3.00 88 28.90 7,629.60 264.00
3 Column RHS 150x100x8 S355 1.80 76 28.90 3,953.52 136.80
4 Beams RHS 150x100x8 S355 4.50 406 28.90 52,800.30 1,827.00
12.00 577.00 200,103.60 5%
5 Beams RHS 150x100x8 S355 3.00 1173 28.90 101,699.10 3,519.00
6 Beams RHS 150x100x8 S355 2.25 8 28.90 520.20 18.00
7 Beams RHS 150x100x8 S355 1.50 552 28.90 23,929.20 828.00
8 Column SHS 100x100x8 S355 1.80 230 22.60 9,356.40 414.00 12.00 37.00 10,034.40 7%
9 Steel Tee T 150x75x12 S355 2.30 746 11.50 19,731.70 1,715.80
12.00 236.00 32,568.00 5%
10 Steel Tee T 150x75x12 S355 1.60 609 11.50 11,205.60 974.40
11 Angle Conn. @ B2,B4 L 75x75x10 S235 0.08 810 11.10 674.33 60.75 12.00 6.00 799.20 16%
12 Angle @Col. L 75x75x8 S235 2.30 357 9.00 7,389.90 821.10
12.00 115.00 12,420.00 5%
13 Angle @Col. L 75x75x8 S235 1.60 306 9.00 4,406.40 489.60
14 Angle Conn. @ Tee L 75x75x6 S235 0.05 5420 6.87 1,861.77 271.00 12.00 24.00 1,978.56 6%
15 Angle Conn. @ B1,B3 L 65x65x6 S235 0.10 3324 5.91 1,964.48 332.40 12.00 30.00 2,127.60 8%
16 Allowance for fittings (15%) S235 -- -- -- 41,849.76 -- -- 44,087.90 5%

TOTAL: 320,848.16 338,007.26 5%

496796876.xlsx Page 5
STRUCTURAL STEEL, PERFORATED PANEL & ROOF SCREEN

PLAN AREA COLUMN HEIGHT Louver Length TOTAL PLAN ESF PRICE SCHEDULE (QR)
ROOF SIZES
S/N BUILDING NAME & CODE (mm) UNIT S7 S5 S3 S2 TOTAL QTY Considered AREA
(m2) (mm) (Lm) (m2) Structural Steelworks & Aluminum
Perforated Steel Panels Louvers
1 FACILITY 104 MAIN SECURITY 15,000 x 4,500 67.50 1,800 Nos. 1 1 1 1 4 1,414.20 270.00 411,675.74 143,061.64
2 FACILITY 105 SECURITY PASS 6,000 x 6,000 36.00 1,800 Nos. 1 1 1 1 4 754.24 144.00 219,560.40 76,299.54
3 FACILITY 109 GUARD HOUSE 4,500 x 3,000 13.50 1,800 Nos. 2 1 1 1 5 353.55 67.50 102,918.94 35,765.41
4 FACILITY 203A PUMP BUILDING WATER 6,000 x 3,000 18.00 1,800 Nos. 1 1 1 1 4 377.12 72.00 109,780.20 38,149.77
5 FACILITY 203B PUMP BUILDING FIRE 6,000 x 3,000 18.00 1,800 Nos. 1 1 1 1 4 377.12 72.00 109,780.20 38,149.77
4,500 x 3,000 13.50 3,000 Nos. 1 1 1 1 4 282.84 54.00 82,335.15 28,612.33
6 FACILITY 301 ENLISTED ACOMMODATION 3,000 x 3,000 9.00 3,000 Nos. 1 1 1 1 4 188.56 36.00 54,890.10 19,074.88
18,000 x 4,500 81.00 3,000 Nos. 1 1 1 1 4 1,697.04 324.00 494,010.89 171,673.96
7 FACILITY 303 DINNING SMALL 18,000 x 6,000 108.00 3,000 Nos. N/A 1 1 1 3 1,697.04 324.00 494,010.89 171,673.96
15,000 x 4,500 67.50 3,000 Nos. 1 N/A 1 353.55 67.50 102,918.94 35,765.41
15,000 x 4,500 67.50 3,000 Nos. 1 N/A 1 353.55 67.50 102,918.94 35,765.41
15,000 x 4,500 67.50 3,000 Nos. 1 N/A 1 353.55 67.50 102,918.94 35,765.41
8 FACILITY 304 DINNING FACILITY MEDIUM 15,000 x 4,500 67.50 3,000 Nos. 1 N/A 1 353.55 67.50 102,918.94 35,765.41
6,000 x 4,500 27.00 3,000 Nos. 1 N/A 1 141.42 27.00 41,167.57 14,306.16
6,000 x 4,500 27.00 3,000 Nos. 1 N/A 1 141.42 27.00 41,167.57 14,306.16
3,000 x 4,500 13.50 3,000 Nos. 1 N/A 1 70.71 13.50 20,583.79 7,153.08
6,000 x 4,500 27.00 3,000 Nos. 1 1 N/A 1 3 424.26 81.00 123,502.72 42,918.49
6,000 x 4,500 27.00 3,000 Nos. 1 1 N/A 1 3 424.26 81.00 123,502.72 42,918.49
9 FACILITY 308 OFFICER DINNING ACOMMODATION
12,000 x 4,500 54.00 3,000 Nos. 1 1 N/A 1 3 848.52 162.00 247,005.45 85,836.98
18,000 x 4,500 81.00 3,000 Nos. 1 1 N/A 1 3 1,272.78 243.00 370,508.17 128,755.47
10 FACILITY 311 COMMUNICATION BLDG 9,000 x 6,000 54.00 1,800 Nos. 1 1 1 1 4 1,131.36 216.00 329,340.60 114,449.31
11 FACILITY 315 HAZARDOUS MATERIALS 6,000 x 3,000 18.00 1,800 Nos. 1 N/A 1 2 188.56 36.00 54,890.10 19,074.88
12,000 x 4,500 54.00 3,000 Nos. 1 1 N/A 1 3 848.52 162.00 247,005.45 85,836.98
12 FACILITY 401 ADMIN BLDG MEDIUM 9,000 x 4,500 40.50 3,000 Nos. 1 1 N/A 1 3 636.39 121.50 185,254.09 64,377.74
3,000 x 4,500 13.50 3,000 Nos. 1 1 N/A 1 3 212.13 40.50 61,751.36 21,459.25
21,000 x 3,000 63.00 1,800 Nos. N/A 1 1 329.98 63.00 96,057.67 33,381.05
13 FACILITY 403 C2 BUILDING
18,000 x 3,000 54.00 1,800 Nos. N/A 1 1 282.84 54.00 82,335.15 28,612.33
14 FACILITY 405 ADMINISTRATION CHECKOUT 9,000 x 4,500 40.50 1,800 Nos. 1 N/A 1 212.13 40.50 61,751.36 21,459.25
9,000 x 3,000 27.00 1,800 Nos. N/A 1 N/A 1 141.42 27.00 41,167.57 14,306.16
15 FACILITY 501 CRG-LCS
6,000 x 3,000 18.00 1,800 Nos. N/A 1 N/A 1 94.28 18.00 27,445.05 9,537.44
9,000 x 3,000 27.00 1,800 Nos. 1 1 N/A 1 3 424.26 81.00 123,502.72 42,918.49
16 FACILITY 503 ICC BLDG
6,000 x 3,000 18.00 1,800 Nos. 1 1 N/A 1 3 282.84 54.00 82,335.15 28,612.33
81.00 16,664.00 3,181.50 4,850,912.53 1,685,742.94