Sie sind auf Seite 1von 12

1. What components of a VxRail node must be assigned IP addresses?

 ESXi host. Center. ESR


 and iDRAC
 ESXi host, vSA
 Center. and ESRS
 ESXi host, vSA
 vMouon. and iDRAC
 vSA
 Center. vRealize Log Insight. and vMotion
2. A system administrator wants to check the version of the VxRail Manager Plug-In.
Where can this be done?
 vSphere Client > VxRail Cluster > Configure> VxRail Support
 vSphere Client > Menu Administration > Client Plug-Ins
 vSphere Web Client > Menu Administration > Client Plug-Ins
 VxRail Manager URL > System Health > Client Plug-Ins
3. What is the maximum number of nodes in a VxRail Cluster with 25 GbE?
 32
 64
 96
 128
4. Beginning with VxRail version 4.7, which product license option has changed?
 VSAN
 vCenter
 VMware Log Insight
 vSphere
5. What type of license does the Dell 4100 OS 10 Switch require to support SmartFabric
Services beyond the initial trial period?
 Feature specific licensing for SmartFabric Services
 Full Fabric Mode licensing
 SmartFabric licensing
 Perpetual licensing
6. A VxRail Cluster setup with P570F nodes is used for product evaluation purposes at
customer sites. Before moving the Cluster to another customer site. it needs to be reset.
Where is the image located to complete this task?
 MB Server
 IDSDM
 SATADOM
 BOSS
7. How long does it take for the Primary node to be selected for a VxRail deployment
after all nodes have been powered on?
 15 to 20 seconds
 5 to 10 minutes
 5 to 10 seconds
 15 to 20 minutes
8. What are all of the menu option choices available in the RASR factory reset procedure
when booting from the RASR ISO?
 RASR RESET
CREATE RASRUSB
FACTORY RESET
UPDATE FIRMWARE
EXIT
 RASR RESET
CREATE RASRUSB
FACTORY RESET
REBOOT
UPDATE FIRMWARE
QUIT
 RASR RESET
CREATE RASRUSB
FACTORY RESET
QUIT
 RASR RESET
CREATE RASRUSB
FACTORY RESET
REBOOT
UPDATE FIRMWARE
EXIT
9. You are validating a VxRail deployment of six V570F nodes each with four 10 Gb
connections. The VxRail nodes have not been powered on.
You need to ensure that the Dell EMC ToR switch is configured correctly.
Which command should you use to do this?
 show port-channel summary
 show interface status
 show interface trunk
 show running-config
10. How many nodes can be added simultaneously to an easting VxRail Cluster?
 1
 2
 4
 6
11. You have determined that you need to execute a RASR factory upgrade of a VxRail
v4.7.1xx node. You download the RASR ISO from the Dell Support site.
What is the correct order of steps to finish the upgrade?

 https://www.dumpsbase.com/freedumps/wp-content/uploads/2018/exams/DES-
6321%20V9.files/image002.jpg
12. What VxRail VSAN storage policy should NOT be changed or deleted after the initial
setup?
 VM Encryption Policy
 VSAN Default Storage Policy
 VxRAIL-STORAGE-PROFILLE
 VxRAIL-SYSTEM-STORAGE-PROFILE
13. In which VxRail models is the iDRAC NIC Selection Setting set to Dedicated?
 P570, V570, and S570 only
 E560 and G560 only
 P570, V570, S570 and G560
 E560, P570. V570, and S570
14. What is the correct sequence of steps used by the VxRail NVT workflow?

 https://www.dumpsbase.com/freedumps/wp-content/uploads/2018/exams/DES-
6321%20V9.files/image006.jpg
15. What is the primary use of the VxRail PEQ Addendum?
 Specifying Dell EMC- deployed switches and Stretched Clusters
 Generating the NVT/FDC JSON configuration file
 Deploying customer provided, non-Dell EMC network switches
 Manually configuring VxRail Manager
16. What is the default VLAN ID of the Private Management VLAN network on a VxRail
4.7.x node?
 0
 1
 3939
 4095
17. Where are the vSAN logs stored?
 Standard ESXi host logs
 Master vSAN node
 VSAN appliance VM
 vCenter logs
18. By design, which network is required to have IPv6 Multicast enabled in order to set
up a VxRail with version 4.7.100?
 Public management network
 VSAN network
 vMotion network
 Private management network
19. Which requirement must be met when expanding a VxRail G560F 3 node Cluster
with a 4th G Series node in the same chassis?
 Node must be a hybrid node
 Node requires only the same processor type
 Node requires only the same drive configuration
 Node must be identical to the other three nodes
20. During a VxRail 2 node Cluster deployment, what is a valid connectivity option?
 2×10 GbE
 4×25 GbE
 4 x1 GbE
 2×25 GbE
21. A VxRail Stretched Cluster will be configured with four All-Flash nodes at each site
based on the following requirements:
– PFTT=1
– SFTT=1
– FTM= Erasure Coding
Based on the required usable capacity, what should be the planned capacity of the
design?
 Single Site Capacity=200%
Total Cluster Capacity=400%
 Single Site Capacity= 133%
Total Cluster Capacity=266%
 Single Site Capacity = 100%
Total Cluster Capacity= 200%
 Single Site Capacity=150%
Total Cluster Capacity=300%
22. You have just upgraded a VxRail Cluster from version 4.5.x to version 4.7.x. You
need to ensure that new VxRail 4.7.x nodes will be discovered without having to make
any changes to the nodes.
What action should you take on the existing configuration?
 In vCenter, set the VLAN ID of the Management Network distributed portgroup to 3939
 Add a new VLAN to the ToR switches with ID 3939
 Add a new VLAN to the ToR Switches with ID 3939
In vCenter, set the VLAN ID of the Management Network distributed portgroup to 3939
 Add a new VLAN to the ToR switches with ID 3939
In vCenter, set the VLAN ID of the VxRail Management distributed portgroup to 3939
23. What is the default network traffic configuration for a VxRail node with 2 x 10 GbE
ports?
 Management, vMotion, and Virtual Machines on Uplink1
VSAN on Uplink
 Management and vMotion on Uplink1
VSAN and Virtual Machines on Uplink2
 Management and virtual Machines on Uplink1
VSAN and vMotion on Uplink2
 Management Virtual Machines, and VSAN on Uplink1
vMotion on Uplink2
24. Which settings would you expect to find in the VXRAIL-SYSTEM-STORAGE-
PROFILE?
 FTT = 1
Object space reservation (%) =0
 FTT = 2
Object space reservation (9o) =0
 FTT = 2
Object space reservation (%) =100
 FTT = 1
Object space reservation (%) =100
25. In a VRail Stretched Cluster deployment. what is the required Round Trip Time (RTT)
between sites?
 Primary to Witness site RTT: < 150 ms
Secondary to Witness site RTT: < 150 ms
Primary to Secondary site RTT: < 10 ms
 Primary to Witness site RTT: < 250 ms
Secondary to Witness site RTT: < 250 ms
Primary to Secondary site RTT: < 10 ms
 Primary to Witness site RTT: < 200 ms
Secondary to Witness site RTT: < 200 ms
Primary to Secondary site RTT: < 5 ms
 Primary to Witness site RTT: < 10 ms
Secondary to Witness site RTT: < 10 ms
Primary to Secondary site RTT: < 6 ms
26. What is the minimum number of VxRail nodes required for a SAN storage policy with
FTT = 2 and FTM set to Erasure Coding?
 4
 5
 6
 7
27. What command is used to restart the Loudmouth process on a VxRail node?
 /usr/lib/vmware/loudmouth/bin/loudmouth restart
 systemctl restart loudmouth
 systemctl restart vmware-loudmouth
 /etc/init.d/loudmouth restart
Question was not answered

28. A VxRail solution will be deployed with the embedded VCenter and Log Insight. Prior
to deployment, DNS records must be created for which entities?
 vCenter Server, ESXi hosts. VxRail Manager, and Log Insight only
 vCenter Server, Platform Services Controller ESXi hosts, VxRail Manager, and Log
Insight only
 ESXi Hosts, VxRail Manager Log Insight, and iDRAC only
 vCenter Server, Platform Services Controller ESXi hosts, VxRail Manager, Log Insight, and
iDRAC
29. What data protection methods are included with the VxRail Appliance?
 Stretched Clusters
NetBackup
vSphere Replication
 Stretched Clusters
RecoverPoint for VMs
vSphere Replication
 vSphere Replication
RecoverPoint for VMs
Avamar
 RecoverPoint for VMs
Data Domain
Stretched Clusters
30. What are the categories that can be validated by the VxRail NVT?
 Network Services, TOR Switches and Upstream Switches
 TOR Switches and Upstream Switches only
 VxRail Appliance, Network Services, and ToR Switches
 VxRail Appliance, ToR Switches, and Upstream Switches
31. You are configuring SmartFabric Services on a VxRail running version 4.7.x.
What is the maximum number of separate vCenter instances that an OMNI plug-in can
be registered with in a single fabric?
 1
 2
 5
 10
Question was not answered
32. A VxRail Stretched Cluster deployment will have E560F nodes. The Cluster must
allow local protection with both erasure coding options at either site.
What is the minimum node configuration?
 3+3 nodes
 4+4 nodes
 6+6 nodes
 8+8 nodes
33. Which log bundles can be included in VxRail automated log collection used for
troubleshooting?
 ESXi, Loudmouth, and PTAgent
 Mystic, Loudmouth, and IDRAC
 VxRail, Mystic, and vCenter
 VxRail, ESXi, and vCenter
34. A customer. new to HCl and VxRail, has a Microsoft SharePoint workload that they
would like to use as their main application.
Which VxRail model is the best option for them?
 S Series
 G Series
 P Series
 E Series
35. What is the purpose of the As-Built Configuration Generator?
 Create the customer deliverable documentation of the Dell EMC product/solution
implementation
 Provide advanced control grouping for Stretched clusters
 Capture and generate the installation workflow for review in the event of a failed deployment
 Keep a record of all spare nodes, not yet added to a VxRail Cluster
36. Which service determines the primary node after powering on Dell PowerEdge-based
VxRail nodes during the deployment of a VxRail Appliance?
 Marvin
 Election
 PTAgent
 Loudmouth
37. A VxRail Stretched Cluster will have four hybrid nodes at each site.
What is the recommended storage policy to ensure cross-site and local protection using
storage as efficiently as possible?
 PFTT=1
SFTT=0
FTM=Erasure Coding
 PFTT=1
SFTT=1
FTM=Erasure Coding
 PFTT=1
SFTT=1
FTM=Mirroring
 PFTT=0
SFTT=1
FTM=Mirroring
38. Which vSAN feature requires an All-Flash Cluster?
 Erasure Coding
 Storage Policy Based Management
 Data-at-Rest Encryption
 VSAN Software Checksum
39. What are some of the items contained in a VxRail As-Built Configuration report?
 Security updates
Support matrices
Firewall Ports listing
 Security updates
Upgrade path
Firewall Ports listing
 System configuration
Firewall Ports listing
Support matrices
 System configuration
Support matrices
Upgrade procedures
40. What does the VxRail NVT validate when only Network Services Validation is
enabled?
 VLAN configuration, NTP and DNS settings
 IP address conflicts, NTP and DNS settings
 VLAN and LACP configurations
 VLAN and STP configurations
41. How is the primary node determined after powering on a Cluster of P570 VxRail
nodes during the deployment of a VxRail Appliance?
 Loudmouth
 Marvin
 Node Selection
 Election
Question was not answered

42. What is the purpose of the PTAgent on a PowerEdge-based VxRail node?


 Hardware monitoring, SATADOM updating and firmware installation
 Hardware discovery, hardware monitoring, and VxRail VIB installation
 Hardware monitoring, SATADOM updating, and VxRail node election
 Hardware discovery, hardware monitoring, and firmware installation
43 . A 4-node VxRail Model E560F solution with an embedded vCenter and Log Insight
is planned for deployment.
Prior to deployment, DNS records must be created for which hosts?
 vCenter Server, ESXi hosts, VxRail Manager, and iDRAC
 vCenter Server, first ESXi host, VxRail Manager, and iDRAC
 DNS records are automatically created during VxRail deployment
 vCenter Server, ESXi hosts, VxRail Manager, and Log Insight
Explanation:

Reference: https://www.dellemc.com/en-us/collaterals/unauth/technical-guides-support-
information/products/

converged-infrastructure/h15300-vxrail-network-guide.pdf
44. What is the default network traffic configuration for a VxRail node with 2 x 10 GbE
ports?

Management and vMotion on Uplink1
vSAN and Virtual Machines on Uplink2
 Management, Virtual Machines, and vSAN on Uplink1
vMotion on Uplink2
 Management, vMotion, and Virtual Machines on Uplink1
vSAN on Uplink2
 Management and Virtual Machines on Uplink1
vSAN and vMotion on Uplink2
45. What is required to enable vSAN encryption on a VxRail cluster?
 All-Flash system
External Key Management Server
 Internal vCenter Server
Internal Key Management Server
 External vCenter Server
External Key Management Server
 Internal vCenter Server
External Key Management Server
Explanation:

Reference: https://docs.vmware.com/en/VMware-
vSphere/6.7/com.vmware.vsphere.virtualsan.doc/GUIDF3B2714F-3406-48E7-AC2D-
3677355C94D3.html
46. A customer is configuring VxRail to connect to an existing, external SRS VE. Their
support account is associated with the Site ID/Party ID where VxRail is installed. A
validation error is issued when the customer attempts to register VxRail in SRS.
What is the possible cause for the error?
 Status of VxRail in Install Base is ‘Shipped’
 Wrong IP address was used for SRS VE gateway
 SRS traffic goes through a proxy server
 Number of deployed devices on SRS gateway has exceeded the maximum
Explanation:

Reference: https://www.dell.com/community/VxRail/ESRS-on-VxRail-Manager/td-p/7147964
47. An implementation engineer is attempting to add a new node to a 3 node VxRail
cluster.
What is the minimum VxRail code version that no longer requires the fourth node to
match the first three nodes?
 4.0.302
 4.0.502
 4.5.070
 4.5.150
Explanation:

Reference: https://www.vstecs-dellsolutions.com/wp-content/uploads/2018/10/vxrail-faq.pdf
48. What is the minimum number of VxRail hosts required if FTT = 1 and FTM is set to
Erasure Coding?
 3
 4
 5
 6
Explanation:

Reference: https://wuchikin.wordpress.com/2016/12/04/how-many-nodes-are-need-on-vxrail
49. A Dell EMC solutions architect has updated the VxRail PEQ with Customer Top-of-
Rack (ToR) switch details.
On which worksheet would they need to be to generate a new NVT JSON file?
 Engagement Details
 Networking Details
 Customer
 VxRail Cluster
50. A failure occurs during the deployment of a VxRail cluster. You need to look through
the marvin.log file to see what could be causing the error.
Where is this file located?
 var/log/vmware/marvin
 var/log/vmware
 var/log/vmware/marvin/tomcat/logs
 var/log/mystic
Explanation:

Reference: https://www.javydekoning.com/vxrail-monitoring-managing/
51. The vCenter managing a VxRail cluster must be able to support both Enhanced
Linked Mode and Vsan Encryption.
What is the correct configuration to satisfy this requirement?
 External vCenter
External PSC
 Embedded vCenter
Embedded PSC
 External vCenter
Embedded PSC
 Embedded vCenter
External PSC
52. Where is the VxRail Manager pre-installed on a newly shipped, 4 node VxRail Model
G410 system?
 Node with the highest serial number
 Bottom-right node from the front
 All nodes
 First node
53. In a 5 node VxRail cluster in which all nodes are the same model, which cluster
requires the least amount of rack space?
 G560
 E560
 S570
 V570
54. A newly installed VxRail system appears to have poor vSAN performance for all VMs
on the cluster.
What can be used to identify the issue?
 esxtop with v view
 resxtop with d view
 esxtop with x view
 resxtop with s view
55. What is not a requirement for a VxRail External vCenter deployment?
 FQDN of the Embedded PSC
 FQDN of the vCenter Server
 An existing datacenter name to be used for the VxRail cluster
 Verification that the DNS server can resolve all VxRail ESXi hostnames
Explanation:

Reference: https://www.dellemc.com/et-ee/collaterals/unauth/technical-guides-support-
information/products/

converged-infrastructure/h15844-vxrail-4-0-vcenter-server-pg.pdf
56. Which vSAN setting is enabled by default during the initial deployment of a VxRail
cluster?
 Deduplication and Compression
 Performance Service
 Storage policy of FTT = 1
 Encryption
Explanation:

Reference: https://www.dellemc.com/en-us/collaterals/unauth/technical-guides-support-
information/products/

converged-infrastructure/h15104-vxrail-appliance-techbook.pdf (15)
57. What is used to control remote access to VxRail through SRS?
 VxRail Manager
 SRS VE Gateway
 vCenter
 Policy Manager
Explanation:

Reference: https://www.dellemc.com/en-us/collaterals/unauth/technical-guides-support-
information/products/

converged-infrastructure/h15300-vxrail-network-guide.pdf
58. How many nodes can be added simultaneously to an existing VxRail cluster running
at code version 4.5?
 1
 3
 6
 8
Explanation:

Reference: https://www.dellemc.com/resources/en-us/asset/technical-guides-support-
information/products/

converged-infrastructure/docu86660.pdf
59. What output logs are collected using the vc-support.sh script?
 vCenter log bundle
 ESXi log bundle
 vRealize Log Insight support bundle
 VxRail Manager log bundle
18. DRAG DROP
What is the correct order of steps to install a Dell PowerEdge-based VxRail cluster?

 https://www.dumpsbase.com/freedumps/wp-content/uploads/2018/exams/DES-
6321%20V8.files/image002.jpg
60. DRAG DROP
Match the management tool that is used to perform the associated operation in a VxRail
environment.

 https://www.dumpsbase.com/freedumps/wp-content/uploads/2018/exams/DES-
6321%20V8.files/image006.jpg
61. In addition to the VxRail YouTube video, links to what resources should the SE send
to the customer, according to the VxRail PEQ Engagement Details worksheet?
 VxRail vCenter Server Planning Guide
VxRail Network Guide
 VxRail QuickStart Guide
VxRail Network Guide
 VxRail vCenter Server Planning Guide
Network Validation Tool
 VxRail QuickStart Guide
Network Validation Tool
62. What does vSAN use to make metadata available to each host in the VxRail cluster?
 Loudmouth
 CMMDS
 MLD Snooping and Querier
 IPv6 Multicast
63. You are validating that a network environment is ready for a 4 node VxRail Model
V570F deployment.
What types of DNS records must be created for VxRail components before
implementation can begin?
 Forward (A) records only
 Forward (A) records and Reverse (PTR) records
 Forward (A) and MX records
 NS records and Reverse (PTR) records
Explanation:

Reference: https://www.dellemc.com/en-us/collaterals/unauth/technical-guides-support-
information/products/

converged-infrastructure/h15300-vxrail-network-guide.pdf (30)
64. Which port configuration is invalid on the integrated NIC of a VxRail node?
 2 x 25 GbE SFP28
 2 x 10 GbE RJ45
 2 x 10 GbE SFP+
 2 x 1 GbE RJ45
Explanation:

Reference: https://www.dellemc.com/en-us/collaterals/unauth/technical-guides-support-
information/products/

converged-infrastructure/h15300-vxrail-network-guide.pdf (10)
65. Which command can be used from VxRail Manager VM to restart the loudmouth
daemon?
 systemctl restart loudmouth
 /etc/init.d/vmware-loudmouth restart
 systemctl restart vmware-loudmouth
 /etc/init.d/loudmouth restart

Das könnte Ihnen auch gefallen