Int. J. Civil Engg. Conc.Structs 2016 P K Bhargava and Atul Kumar Agarwal, 2016
*
Quantum School of Technology, Roorkeee
**
Scientist 'F' CSIR-Central Building Reseach Institute, Roorkee
Table: xxxxxxxxxxxxxxxx
Climatic Zone Mean Mean TSI is defined as the temperature of calm air,
monthly monthly
at 50% relative humidity which imparts the
maximum relative
Temperature C O
Humidity %
some thermal sensation as the given
Hot-Dry above 30 below 55 environment. Mathematically TSI is
Warm-Humid above 30 55above expressed as
Temperate above 25 above 75
Cold between 25-30 75below
TSI = 0.745 ta + 0.308 tw – v + 0.841
Composite below 25 all values Where ta = dry bulb (globe)
following
temperature, °C.
Criteria paragraph
explained tw = wet bulb temperature °C
in the
v = air speed in m/sec
Comfort Requirements
Comfort conditions depend upon air The thermal comfort of people lies
temperature, relative humidity, wind speed, between TSI values of 25 and 30°C with
as well as on clothing, acclimatisation, age, maximum per cent of people being
sex, and type of activity of the people. Based comfortable at 27.5°C. On lower side , the
on exhaustive studies carried out on thermal coolness of environment is tolerable
comfort at C.B.R.I. Roorkee, a Tropical between 19 and 25°C (TSI) and below 19°C
Summer Index (TSI) representing the (TSI) it is too cold. This clearly indicates that
combined effect of temperature, relative for achieving comfortable environment
humidity and wind speed was evolved. The indoors, heating up to 19OC is necessary in
winter, where as steps need to be taken to responsible for raising the temperature of
achieve indoor conditions conforming to TSI exterior surface of the envelope and also for
values around 27.5OC in summer. creating temperature gradient across the
thickness of envelope. As a result of this,
Passive Cooling Techniques heat is conducted indoors causing thereby a
Development of passive cooling rise in the interior surface temperature.
techniques is based on two basic concepts. Hence, reduction in the temperature of
First of all the internal heat which comprises exterior surface is necessary for keeping the
of the heat liberated by building occupants indoor surface temperature at a low value.
and the heat generated due to various Transparent window facing sun also permits
activities performed indoors should be direct entry of sun. This also contributes to
reduced to minimum by provision of the rise in the temperature of indoor surfaces.
proper ventilation system such as local Hence, control of direct entry of sun through
exhaust right above the source of heat. windows is an essential requirement for
Secondly, the heat which penetrates through preventing rise in interior surface
the building envelope should be temperature. Based on these considerations,
minimized. The three different ways of heat various methods have been evolved for
entry from outside to inside the buildings curtailment of heat flow through building
are (i) Direct penetration of sun through envelope. A few of them are discussed
windows (ii) Conduction of heat through below;
walls and roof (iii) Infiltration of outside air
Optimum Orientation
when its temperature is higher than indoor
air temperature. Based on these concepts It is well known that the amount of daily
different techniques of passive cooling of solar radiation incident per unit area on N
buildings have been conceived. In context and S facing walls is much less as compared
with cooling of buildings in hot dry and to that on the walls facing other directions.
warm humid climates, the passive Hence, for minimum solar heat gain by the
techniques mainly aim towards reduction building envelope, it is desired that the
in heat penetration through building longer axis of building should lie along East-
envelope and provision of fenestration for West direction. Further, the effect of
inducing desired natural ventilation orientation of a building on heat penetration
indoors. Few of these techniques are through envelope also depends on the
discussed below; aspect ratio (length/breadth) of the building.
For a building with square plan (aspect ratio
Reduction in Heat 1:1) and glass area equally distributed on all
the four walls, the effect of orientation is nil,
Penetration through while for a rectangular building with aspect
Building Envelope ratio 2:1, the fabric load is reduced by 30 per
Solar radiation incident on building cent due to change in orientation from worst
envelope is the main source of heat to best.