Sie sind auf Seite 1von 1

VAI PARA A MEDIÇÃO

QDC
TENSÃO NOMINAL 220/127V
POTÊNCIA TOTAL 24,17kVA
A POTÊNCIA DEM. 18,45kVA
I DEM. 48,48A
DISTÂNCIA 20m
(3#16+N#16+T#16) - PVC 450/750V

DISJ 3P
63A
DPS 275V
5kA
CLASSE II

63A

30mA

10A 10A 16A 16A 20A 16A 16A 16A 16A 40A 20A 10A 16A 16A 20A
3kA 3kA 3kA 3kA 3kA 3kA 3kA 3kA 3kA 3kA 3kA 3kA 3kA 3kA 3kA

#2,5 #2,5 #2,5 #2,5 #4,0 #2,5 #4,0 #4,0 #2,5 #6,0 #2,5 #2,5 #2,5 #2,5 #2,5

ILUM. ILUM. TUG. TUG. M.LAV. TUG. TUG. TUG. TUG. CHUV. ARC1. RES. RES. RES. RES.
460W 360W 2900W 1350W 1800W 1300W 1900W 2400W 1400W 7800W 1100W --- --- --- ---
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15

DISTRIBUIÇÃO DE TOMADAS E ILUMINAÇÃO CASA DESAFIO 7 DIAS


ESCALA: 1/25

220V 3F+N+T 60hz

(3#6+N#6+T#6) EPR
NOTAS GERAIS

1 - CONDUTORES E ELETRODUTOS COM DIMENSÕES NÃO INDICADAS EM PROJETO, DEVERÃO SER DE


NEUTRO PE
#2,5 PARA TUGS, #1,5 PARA ILUMINAÇÃO E Ø3/4" RESPECTIVAMENTE.
DISJUNTOR
2 - CONDUTORES DE PROTEÇÃO (TERRA) COM BITOLAS NÃO INDICADAS EM PROJETO DEVERÃO SER DE 3P 32A
#2,5 PARA TUGS E #1,5 PARA ILUMINAÇÃO E COR VERDE OU VERDE E AMARELHO. QFL01 - 220/127V
3 - OS CABOS UTILIZADOS EM INSTALAÇÕES DE CIRCUITOS TERMINAIS COM ISOLAÇÃO EM PVC DEVERÃO POTENCIA TOTAL INST: 12,5 kVA - 32,84A DR
SER DOS TIPOS PIRASTIC-FLEX, DUPLAST OU SINTENAX/ECONAX E PARA O USO DE EPR UTILIZAR TIPO AFUMEX.
POTENCIA DEM. 8,125 kVA - FD: 0,65 - 21,34A 40A
30mA
4- UTILIZAR O PADRÃO DE COR DE CABOS DE ACORDO COM A NBR5410, CONDUTORES FASE
(VERMELHO, PRETO E AMARELO), NEUTRO (AZUL) E RETORNO (BRANCO). AREA POT (VA) CURV (A) CIRC CIRC CURV (A) POT (VA) AREA NA

ILUM. COZINHA 600 B 10 1 2 B 10 600 ILUM. SALA


5- TODOS OS CABOS UTILIZADOS EM ALIMENTADORES DEVERÃO TER A ISOLAÇÃO EM EPR OU XLPE
(TIPO AFUMEX OU EPROTENAX).
ILUM. LAV, VAR, CIRC 500 B 10 3 4 B 10 800 ILUM. GARAGEM
6- TUBULAÇÕES EMBUTIDAS DEVERÃO SER DO TIPO PVC FLEXÍVEL, ENQUANTO QUE TUBULAÇÕES APARENTES
DEVERÃO SER DO TIPO AÇO GALVANIZADO À FOGO (RÍGIDO), CASO FIQUE AO AR LIVRE (SE APLICÁVEL) TUG SALA 1200 B 20 5 6 C 20 800 TUE SPLIT AR COND
AZUL CLARO

PLACA DE IDENTIF. DE
PROTEÇÃO
VERMELHA

TENSÃO FUNDO AMAR.


RETORNO
AMARELO

LETRA PRETA
7- OS REATORES DE LÂMPADAS DE DESCARGA DEVERÃO SER DE ALTO FATOR DE POTÊNCIA.
BRANCO
NEUTRO
FASE L1

FASE L2

FASE L3

TOMADA 2P+T - PADRÃO BRASILEIRO


TUG COZINHA/GARAG 1200 B 20 7 8 C 20 600 TUE GELADEIRA
PRETO

VERDE

NBR 14136 PINOS CILÍNDRICOS Ø4,8mm


COR VERMELHA PARA TOMADAS NO BREAK
COR PRETA PARA TOMADAS REDE COMUM 220V

8- AS TOMADAS E PLUGUES DEVERÃO ATENDER OS PADRÕES DA NBR-14136


TUG COZINHA 2000 B 20 9 10 C 20 2200 TUG COZINHA
DETALHE DE LIGAÇÃO E POLARIZAÇÃO DAS TOMADAS
SEM ESCALA DET. CORES DOS CABOS 9- TUBULAÇÕES DEVERÃO SER 3/4", EXCETO QUANDO INDICADO EM PROJETO.
S/ ESC.
RESERVA ILUM 127V 400 B 10 11 12 B 10 400 RESERVA ILUM 127V
10- TODAS AS INSTALAÇÕES DEVERÃO OBEDECER OS PADRÕES DEFINIDOS PELA NBR5410 E NR10.
RESERVA TUG 220V 600 C 20 13 14 B 20 600 RESERVA TUG 220V
11- UTILIZAR TOMADAS, PLUGUES E INTERRUPTORES DE FABRICANTES CERTIFICADOS COMO STECK, WEG,
SIEMENS, SCHNEIDER, PIAL OU SIMILAR.

ESCOLA DA ELÉTRICA