ADEN TOURISTIC RESIDENTIAL PROJECT - APARTMENT BUILDING - MAT FOUNDATION DESIGN

Mat Foundation calculation


General remarks:
1- Type of foundation (mat foundation)
2- mat foundation dimension ( L=42.20 m & W=40.70m)

mat foundation Analysis:


using staadpro2008 Program for analysis results are attached
ADEN TOURISTIC RESIDENTIAL PROJECT - APARTMENT BUILDING - MAT FOUNDATION DESIGN

Design of mat foundation thick acoording to Design Code ACI 318 -02

1 cheak punching under shear wall 1;


Fc = 30 MPa.
Fy = 420 MPa.
Assume t of footing = 1.10 m
d= 1.03 m
Support dimention a= 6.4 m
(shear wall 1) b= 0.3 m
Ultimate Load Pu= 15587 kN from analysis result under shear wall 1
Load compination 35
Result
1- Check of depth for Tow-way shear (Punching)
bo=2*(a+d)+2*(b+d)= 17.52 m
Section strength for Punching

 2 x4  1
Vc = 1 +
'
 f c .bo .d 16988 KN > Pu ok
 βc  6

α d  1
Vc =  s + 2
'
f c .bo .d 26882 KN
 bo  12
1
Vc =
'
f c .bo .d 24710 KN
3

1 cheak punching under shear wall 2;


Fc = 30 MPa.
Fy = 420 MPa.
Assume t of footing = 1.10 m
d= 1.03 m
Support dimention a= 6.4 m
(shear wall 2) b= 0.3 m
Ultimate Load Pu= 15990 kN from analysis result under shear wall 2
Load compination 33
Result
1- Check of depth for Tow-way shear (Punching)
bo=2*(a+d)+2*(b+d)= 17.52 m
Section strength for Punching

 2 x4  1
Vc = 1 +
'
 f c .bo .d 16988 KN > Pu ok
 βc  6

α d  1
Vc =  s + 2
'
f c .bo .d 26882 KN
 bo  12
1
Vc =
'
f c .bo .d 24710 KN
3
ADEN TOURISTIC RESIDENTIAL PROJECT - APARTMENT BUILDING - MAT FOUNDATION DESIGN

1 cheak punching under shear wall 3;


Fc = 30 MPa.
Fy = 420 MPa.
Assume t of footing = 0.8 m
d= 0.73 m
Support dimention a= 6.4 m
(shear wall 4) b= 0.3 m
Ultimate Load Pu= 10325 kN from analysis result under shear wall 4
Load compination 47
Result
1- Check of depth for Tow-way shear (Punching)
bo=2*(a+d)+2*(b+d)= 16.32 m
Section strength for Punching
 2 x4  1
Vc = 1 +
'
 f c .bo .d 11215 KN > Pu ok
 βc  6

α d  1
Vc =  s + 2
'
f c .bo .d 15454 KN
 bo  12

1
Vc =
'
f c .bo .d 16313 KN
3

1 cheak punching under shear wall 4;


Fc = 30 MPa.
Fy = 420 MPa.
Assume t of footing = 1.03 m
d= 0.96 m
Support dimention a= 2.8 m
(shear wall 4) b= 0.3 m
Ultimate Load Pu= 12253 kN from analysis result under shear wall 4
Load compination 32
Result
1- Check of depth for Tow-way shear (Punching)
bo=2*(a+d)+2*(b+d)= 10.04 m
Section strength for Punching

 2 x4  1
Vc = 1 +
'
 f c .bo .d 12255 KN > Pu ok
 βc  6

α d  1
Vc =  s + 2
'
f c .bo .d 19218 KN
 bo  12

1
Vc =
'
f c .bo .d 13198 KN
3
ADEN TOURISTIC RESIDENTIAL PROJECT - APARTMENT BUILDING - MAT FOUNDATION DESIGN

1 cheak punching under Shear wall 5;


Fc = 30 MPa.
Fy = 420 MPa.
Assume t of footing = 1.1 m
d= 1.03 m
Support dimention a= 5.6 m
(Column 1) b= 0.3 m
Ultimate Load Pu= 12000 kN from analysis result under Shear wall 5

Result
1- Check of depth for Tow-way shear (Punching)
bo=2*(a+d)+2*(b+d)= 15.92 m
Section strength for Punching
 2 x4  1
Vc = 1 +
'
 f c .bo .d 16038 KN > Pu ok
 βc  6

α d  1
Vc =  s + 2
'
f c .bo .d 25754 KN
 o
b  12

1
Vc =
'
f c .bo .d 22453 KN
3

1 cheak punching under core wall 6;


Fc = 30 MPa.
Fy = 420 MPa.
Assume t of footing = 1.1 m
d= 1.03 m
Support dimention a= 3.05 m
(Column 1) b= 3.05 m
Ultimate Load Pu= 22230 kN from analysis result under shear wall 5
Load compination 49
Result
1- Check of depth for Tow-way shear (Punching)
bo=2*(a+d)+2*(b+d)= 16.32 m
Section strength for Punching
 2 x4  1
Vc = 1 +
'
 f c .bo .d 103579 KN
 βc  6

α d  1
Vc =  s + 2
'
f c .bo .d 26036 KN
 bo  12

1
Vc =
'
f c .bo .d 23017 KN > Pu ok
3
ADEN TOURISTIC RESIDENTIAL PROJECT - APARTMENT BUILDING - MAT FOUNDATION DESIGN

1 cheak punching under core wall 7;

Fc = 30 MPa.
Fy = 420 MPa.
Assume t of footing = 1.1 m
d= 1.03 m
Support dimention a= 27.7 m
(Column 1) b= 0.3 m
Ultimate Load Pu= 39500 kN from analysis result under shear wall 6
Load compination 47
Result
1- Check of depth for Tow-way shear (Punching)
bo=2*(a+d)+2*(b+d)= 60.12 m
Section strength for Punching
 2 x4  1
Vc = 1 +
'
 f c .bo .d
46070 KN ok
 βc  6 > Pu

α d  1
Vc =  s + 2
'
f c .bo .d 56923 KN
 bo  12

1
Vc =
'
f c .bo .d 84792 KN
3
ADEN TOURISTIC RESIDENTIAL PROJECT - APARTMENT BUILDING - MAT FOUNDATION DESIGN

Design of mat foundation Reinf. acoording to Design Code ACI 318 -02

INPUT
Fc = 30 MPa.
Fy = 420 MPa.
t of footing = 1.20 m
d= 1.13 m

Result 1 (main Reinforcement):

1- Design of steel in long direction (L) Bottom 3- Design of steel in long direction (L) top
from analysis result Mu = 2400 kN.m from analysis result Mu = 2400 kN.m
Ru = 1.880 MPa. Ru = 1.880 MPa.
Ratio of rainforcement = 0.0052 % Ratio of rainforcement = 0.0052 %
min Ratio of rainf. 0.0020 % min Ratio of rainf. 0.0020 %
As = 5869.87 mm2 As = 5869.87 mm2
12.0 φ 25 /m' 12.0 φ 25 /m'

2- Design of steel in short direction (B) Bottom 4- Design of steel in short direction (B) top
from analysis result Mu = 1250.00 kN .m from analysis result Mu = 1250.00 kN .m
Ru = 0.979 MPa. Ru = 0.979 MPa.
Ratio of rainforcement = 0.0026 % Ratio of rainforcement = 0.0026 %
min Ratio of rainf. 0.0020 % min Ratio of rainf. 0.0020 %
As = 2925 mm2 As = 2925 mm2
6.0 φ 25 /m' 6.0 φ 25 /m'

Result 2 (Additional reinforcement under shear wall 1):


2- add bottom steel in long direction (L) 3- add bottom steel in short direction (B)
from analysis result Mu = 0 kN.m from analysis result Mu = 1300 kN.m
Ru = 0.000 MPa. Ru = 1.018 MPa.
Ratio of rainforcement = 0.0000 % Ratio of rainforcement = 0.0028 %
As = 0.00 mm2 As = 3114.18 mm2
0.0 φ 25 /m' 7.0 φ 25 /m'

Result 3 (Additional reinforcement under shear wall 6):


2- add bottom steel in long direction (L) 3- add bottom steel in short direction (B)
from analysis result Mu = 1400 kN.m from analysis result Mu = 2750 kN.m
Ru = 1.096 MPa. Ru = 2.154 MPa.
Ratio of rainforcement = 0.0030 % Ratio of rainforcement = 0.0060 %
As = 3359.89 mm2 As = 6772.43 mm2
7.0 φ 25 /m' 14.0 φ 25 /m'