ER18505: A Size Bobbin Cell

Technical Datasheet

Technical Specifications
Part No. ER18505 (UHE-ER18505)
Cell Type Primary, non-rechargeable
Chemistry Lithium Thionyl Chloride
Voltage Range 2.0V to 3.7V
Nominal Voltage 3.6V
Nominal Capacity 4.0Ah @ 1mA to 2.0V @ 23°C
Max. Continuous Discharge Current 100mA
Max. Pulse Discharge Current Up to 200mA
Weight 32g
Operating Temperature -55°C to 70°C
70°C to 85°C (max of 24 hours)
Storage Temperature 1 -55°C to 70°C
70°C to 85°C (max of 24 hours)
Features
• High and stable operating voltage Exterior/Housing Stainless steel container
• Higher power and higher energy for the Terminals/Connector Radial tabs / radial pins / axial leads / flying leads
whole battery life
Transportation 2
A complete description of transportation
• Superior drain capability regulations, lithium weights and transportation
• Higher power applications classifications is available on the Ultralife website.
• Low self-discharge rate (less than 1% after
Quality Assurance Ultralife manufacturing facilities are ISO 9001:2008
1 year of storage at +20°C)
and ISO 14001:2004 registered. Its products
• Battery life higher than 10 years,
are listed under the Component Recognition
depending on the application
Program of Underwriters Laboratories (UL) and
• Hermetic glass-to-metal sealing
have passed UN transportation testing, which
• Avoid leakage, key for a higher than
is required for international transportation of all
10 year battery life
lithium batteries.
• Non-flammable electrolyte
• Safer operation in case of abuse Notes
1. Cells should be stored in temperatures less than 30°C for a shelf-life of greater than five years.
2. A complete description of transportation regulations, lithium weights and transportation classifications is
Typical Applications available on the Ultralife website.

• Military and other radio applications


• Alarm and security systems
• Beacons and emergency location
transmitters
• GPS
• Metering systems
• Sonobuoys
• LED lighting applications

ER18505
Newark, New York | +1 315-332-7100 | Fax: +1 315-331-7800
©2017 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. • 14 NOV 17 UBM-0063 Rev: B
Dimensions

Typical Performance Graphs

Constant Load Discharge Voltage versus Discharge Time at 25°C Voltage versus Temperature at Different Discharge Currents
ER18505 ER18505
4.0
3.8
3.8
3.7
3.6 3.6
Discharge Voltage (V)
Discharge Voltage (V)

3.4 3.5

3.2 3.4 10µA


3.0 3.3 0.2mA
1mA
2.8 33Ω-100mA-1.6Ah-16h 3.2
100mA
100Ω-33mA-2.5Ah-76h 3.1
2.6
330Ω-10mA-2.8Ah-280h
3.0
2.4 3.5kΩ-1mA-4.0Ah-4000h
18kΩ-0.2mA-3.2Ah-16000h 2.9
2.2
2.8
2.0
0

20

40

60

80
-60

-40

-20
10000
100
1

100000
1000
10

Discharge Time (h) Temperature (°C)

High and flat voltage at high and low drain High voltage at high drain even at -30°C

ER18505
Newark, New York | +1 315-332-7100 | Fax: +1 315-331-7800
©2017 Ultralife Corporation • www.ultralifecorp.com • All information is subject to change without notice.
The information contained herein is for reference only and does not constitute a warranty of performance. • 14 NOV 17 UBM-0063 Rev: B