Beruflich Dokumente
Kultur Dokumente
THERM S-I/FS-I
Planning Steel curtain wall
System benefits
System sections
System sections 50/56/76/96 mm
THERM+ S-I
THERM+ S-I Assembly options
System sections Polygon glazing system
Cover/Pressure profile options
Building connections
THERM+ S-I
Add-ons
THERM+ S-I Burglar resistant curtain wall RC3
Add-ons Fire resistant curtain wall
Structural Glazing SG2
Assembly options
Connector technology
THERM+ S-I
Glazing/Sealing technology
THERM+ S-I
Accessories
Assembly options
Connection profiles
Statics
System benefits
System sections
THERM+ FS-I
System sections 50/56 mm
THERM+ FS-I Assembly options
System sections Polygon glazing system
Cover/Pressure profile options
Building connections
THERM+ FS-I
Burglar resistant curtain wall RC2
Add-ons
THERM+ FS-I
Burglar resistant curtain wall RC3
Add-ons
Structural Glazing SG2
Assembly options
Connector technology
THERM+ FS-I
Glass weights
THERM+ FS-I
Glazing/Sealing technology
Assembly options
Accessories
Connection profiles
Integration elements
THERM+ S-I/FS-I
2017 3
4 2017
Content
System sections
THERM+ S-I
System benefits
Technology in detail 7
Tests 9
Variants 10
Corrosion protection 12
Ventilation 13
Sealing system 17
System sections
System width 50 mm 19
System width 56 mm 47
System width 76 mm 74
System width 96 mm 95
Building connections 50/56/76 mm 96
2017 5
6 2017
THERM+ S-I
System benefits
System sections
THERM+ S-I
Technology in detail
■ Optimum planning
– Dissipating for very high glass weights up to 800 kg,
with additional components up to 1.500 kg.
– Vertical curtain wall and glass roof up to 2° roof inclination.
– Construction as polygon curtain wall up to 45° with system
accessories.
– Entire imposed load admitted by the construction supervising
authority (welding, load transmission, pressure profile bolting).
– Extensive system accessories.
■ Efficient installation
– Patent-registered add-on construction with screw channel
of stainless steel and aluminium.
– Optimal protection against corrosion by constructive saftety
distance of 3 mm between the structural steel profile and the
base profile.
– Special technology for invisible screwed transom connections
with steel pipes.
– Three options for interior gaskets.
– Integrated drainage at the continuous gasket in three levels.
SSI-0001 2017 7
THERM+ S-I
System benefits
8 2017
THERM+ S-I
System benefits
System sections
THERM+ - Certified quality, CE-conform and tested
THERM+ S-I
THERM+ quality you can rely upon.
Extensive product tests with excellent results confirm the high quality in practical applications of the THERM+ curtain wall system wall.
Airborne sound insulation (if specially RW (C;Ctr) = 36 (-1;-4) dB until gbd LAB
4.6
requested) (EN ISO 140-3) RW (C;Ctr) = 47 (-2;-6) dB Nr. 10_1101_11
■ Notice
– All features can be used for CE-Labelling by the manufactures of curtain walls. It is mandatory that only RAICO products has to
be used and the production process has to be monitored by an in-house production control system. The whole production process
has to be compliant to the RAICO assembly instructions.
– Depending on the panel dimensions of the curtain wall and the structural connections the sound insulation value has to be calculated
separately. The system testimonial can only be used for an overview.
– Depending on the different systems options and the glass thickness the Uf-value can be adapted step-by-step. The exacts values
based on DIN EN ISO 10077-2 are documented in the thermal protection documentations by RAICO.
German general approval: – Connection steel structural profile German general approval for DIBt, Berlin
clamping joint for the curtain with system base pofile the fixing system THERM+ steel No. Z-14.4-446
wall system – Glass carriers curtain wall
– Pressure profiles
– Screws
Glass roof with 2° inclination: Class AE including accessories Test of airpermeability ift Rosenheim
Air permeability (e. g. sun protection fixation) acc. to EN 12153:2000-06 No. 13-002240-PR05
Glass roof with 2° inclination: Class RE 1050 to 2550 including Test of water penetration ift Rosenheim
Water penetration accessories (e. g. sun protection acc. to EN 12155:2000-06 No. 13-002240-PR05
fixation)
Glass roof with 2° inclination: Test load up to 2.6 kN/m2, safety Test of wind resistance ift Rosenheim
Wind resistance up to 3.9 kN/m2 (e. g. sun protection acc. to EN 12179:2000-06 No. 13-002240-PR05
fixation)
Burglar prevention Resistance class RC2 for system Test THERM+ S-I gbd LAB
widhts 50, 56 and 76 mm acc. to DIN EN 1627 Nr. 16/1315_02
Burglar prevention Resistance class RC3 for system Test THERM+ S-I gbd LAB
widhts 50, 56 and 76 mm acc. to DIN EN 1627 Nr. 16/1315_03
Passive house curtain wall Ucw ≤ 0.8 W/m2K of system THERM+ Fulfilment all criteria for components Passive house institute
S-I 50, 56 with insulating block P suitable for passive houses Dr. Feist certificate
2017 9
THERM+ S-I
System benefits
■ Drainage system
– The drainage groove of the mullion and
transom gasket is arranged on various levels.
– In all THERM+ systems the ventilation and
drainage principle is so designed that a
controlled condensate removal from
transom to the mullion rebate is secured
via interior gaskets.
System sections
THERM+ S-I
Gasket options
■ Exterior gasket
– Various exterior gaskets and insulating block
Standard exterior gasket
options available.
– Gradual adaptation of the insulation value.
– Maximum thermal insulation up to
Um,t= 0.80 W/(m²K) including screw influence. Insulating block 9
– Certified passive house curtain wall.
– Economic solution.
Insulating block 21
Insulating block P
Insulating block PH
SSI-0003 2017 11
THERM+ S-I
System benefits
■ Safety distance
– Patent-registered add-on construction with
screw channel of stainless steel and
aluminium.
Click
– Optimal protection against corrosion by con-
structive saftety distance of 3 mm between the
structural steel profile and the base profile.
– No superficially bonded components.
– The completely accessible surface enables an
easy and efficient treatment against corrosion
– even in the welding area.
Click
12 2017 SSI-0004
THERM+ S-I
System benefits
System sections
THERM+ S-I
Isothermal lines
■ Isothermal lines
– Double glazing with Ug=1.1 W/(m2K) and
acrylic spacer.
– Already with standard exterior gaskets the
10°C- isothermal line remains completely
within the system.
– Condensate is avoided efficiently.
– Individual adaption at higher risk of conden-
sation is possible (e. g. conservatories and
swimming pools).
THERM+ 50 S-I
■ Formation of condensate with acrylic spacer
SI-0001a 2017 13
THERM+ S-I
System benefits
14 2017 KS-0100
THERM+ S-I
System benefits
System sections
THERM+ S-I
Ventilation options
Option I b: Pressure compensation via mullion and synthetic sealing piece
KS-0102 2017 15
THERM+ S-I
System benefits
to
16 2017 KS-0101
THERM+ S-I
System benefits
System sections
THERM+ S-I
Interior sealing system
3 drainage levels
■ Technical information
– T38 = Level 2.
– T39 = Level 3.
– T40 = Level 1.
– T151 = Interior gasket E3.
– T152 = Interior gasket E2.
– T153 = Interior gasket E1.
– T159 = Interior gasket E2 with flap.
7.5
K-0011 2017 17
18 2017
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Certified passive house curtain wall with insulating block PH and interior gasket D
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 D 150007 20 m
Gasket for transom 50 D 150012 20 m
Insulating block PH 50/29 168513 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012129
screw 5.5x58 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 43 to 44 162080 10 pc(s)
012049
SI-0151 2017 19
THERM+ S-I
System sections 50 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Insulating block PH 50/29 168513 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012129
screw 5.5x58 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 43 to 44 162080 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
012049
20 2017 SI-0136
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Certified passive house curtain wall with insulating block PH and interior gasket L
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 L 150006 20 m
Gasket for transom 50 L 150011 20 m
Insulating block PH 50/29 168513 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012129
screw 5.5x58 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 43 to 44 162080 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
012049
SI-0152 2017 21
THERM+ S-I
System sections 50 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Insulating block P 50/19 168509 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
012049
22 2017 SI-0081b
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Insulating block 21 and standard interior gasket
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Insulating block 50/21 150605 50 m
■ Accessories
26 - 64 mm
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012114
screw 5.5x42 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 27 to 28 162040 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
26 - 64 mm
012049
SI-0016 2017 23
THERM+ S-I
System sections 50 mm
■ Gaskets
Article No. PU
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Insulating block 50/9 151010 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
012049
24 2017 SI-0010b
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Standard exterior gasket
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
012049
SI-0001b 2017 25
THERM+ S-I
System sections 50 mm
■ Profiles
Article No. PU
Cover profile 50/15 013003 6m
Pressure profile 47
118005 6m
punched
Base profile 129005 6m
Connection profile 38/22 168121 6m
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 L 150006 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Pan head tapping 100
012113
screw 5.5x40 pc(s)
500
Base profile carrier 50 168405
pc(s)
Special countersunk 100
908118
sheet metal screw 4.8x19 pc(s)
26 2017 SI-0172
THERM+ S-I
System sections 50 mm
System sections
90°
THERM+ S-I
Corner mullion 90°, vertical
Mullion section
■ Profiles
Article No. PU
Cover profile 50/15 013003 6m
Pressure profile 47
118005 6m
punched
Base profile 129005 6m
Connection profile 38/22 168121 6m
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 L 150006 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Pan head tapping screw 100
012113
5.5x40 pc(s)
500
Base profile carrier 50 168405
pc(s)
Special countersunk 100
908118
sheet metal screw 4.8x19 pc(s)
SI-0173 2017 27
THERM+ S-I
System sections 50 mm
■ Gaskets
Article No. PU
Gasket for pressure prof. 3 011070.LI 100 m
Gasket for pressure prof. 3 011070.RE 100 m
Gasket for mullion 50 D 150007 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Pan head tapping screw 100
012113
5.5x40 pc(s)
Special countersunk 100
908118
sheet metal screw 4.8x19 pc(s)
28 2017 SI-0174
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Overview structural T-profiles
Mullion section
Wall
Surface Weight Height
No. thickn.
area m2 kg/m mm
mm
062010 0.230 7.20 60 8
062020 0.290 9.08 90 8
062030 0.350 13.49 120 10
SI-0003 2017 29
THERM+ S-I
System sections 50 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for transom 50
150015 20 m
with flap
Gasket for transom 50 L
150016 20 m
with flap
Gasket for transom 50 D
150017 20 m
with flap
Gasket for transom 56
150115 20 m
with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
30 2017 SI-0002
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Continuous base gasket with flap
Transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
012049
Compensation gasket 2 011080 100 m
Base gasket for transom
150020 20 m
50 with flap
Base gasket for transom
150021 20 m
50 L with flap
Base gasket for transom
150022 20 m
50 D with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
012049 016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Sealing piece
152071 10 pc(s)
for base transom
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
012049
SI-0002a 2017 31
THERM+ S-I
System sections 50 mm
■ Accessories
012049
32 2017 SI-0165
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Galvanized structures
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
013004
012049
SI-0001a 2017 33
THERM+ S-I
System sections 50 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 L 150006 20 m
Gasket for transom 50 L 150011 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012114
screw 5.5x42 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
100
Special blind rivet 4.8x15 910125
pc(s)
34 2017 SI-0129
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Interior compensation of varying infill thicknesses
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Interior gasket 3 220320 100 m
■ Accessories
Article No. PU
Pan head tapping
012091 100 pc(s)
screw 5.5x16
Pan head tapping
012116 100 pc(s)
screw 5.5x48
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece
152010 100 pc(s)
for transom 50
Glass carrier 33 to 34 162055 10 pc(s)
Base profile carrier 50 168405 500 pc(s)
Fixture spring 26/25/10 915015 50 pc(s)
SI-0005a 2017 35
THERM+ S-I
System sections 50 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping
012107 100 pc(s)
screw 5.5x25
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece
152010 100 pc(s)
for transom 50
Glass carrier 10 to 14 162005 10 pc(s)
Base profile carrier 50 168405 500 pc(s)
012049
36 2017 SI-0005
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Single glazing and interior gasket 26 mm
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50/26 150461 20 m
Interior gasket 50/26 E3 150462 20 m
Interior gasket 50/26 E2 150463 20 m
■ Accessories
Article No. PU
Pan head tapping 100
012109
screw 5.5x30 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152007
for transom 50/26 pc(s)
Sealing piece 100
152011
for transom 50/26 E2 pc(s)
Glass carrier 10/13 167556 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
Special flat fillister head 100
908308
screw 5.5x19 pc(s)
SI-0012 2017 37
THERM+ S-I
System sections 50 mm
■ Accessories
Article No. PU
Pan head tapping 100
012114
screw 5.5x42 pc(s)
500
Base profile carrier 50 168405
pc(s)
38 2017 SI-0018
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Polygon glazing system 8° to 15°
Mullion section exterior angle
■ Accessories
Article No. PU
Pan head tapping 100
012115
screw 5.5x45 pc(s)
500
Base profile carrier 50 168405
pc(s)
SI-0127 2017 39
THERM+ S-I
System sections 50 mm
■ Gaskets
Article No. PU
Gasket for pressure
011805 100 m
profile 5 polygonal
Gasket for mullion 50
150040 20 m
polygonal 8° to 20°
Gasket for mullion 50
150045 20 m
polygonal 21° to 33°
■ Accessories
Article No. PU
Pan head tapping 100
012116
screw 5.5x48 pc(s)
Pan head tapping 100
012117
screw 5.5x50 pc(s)
500
Base profile carrier 50 168405
pc(s)
40 2017 SI-0019
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Polygon glazing system 34° to 45° with polygon interior and exterior gasket
Mullion section exterior angle
■ Gaskets
Article No. PU
Gasket for pressure
011805 100 m
profile 5 polygonal
Gasket for mullion 50
150050 20 m
polygonal 34° to 45°
■ Accessories
Article No. PU
Pan head tapping 100
012119
screw 5.5x55 pc(s)
500
Base profile carrier 50 168405
pc(s)
SI-0020 2017 41
THERM+ S-I
System sections 50 mm
42 2017 SI-0133
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Snap-on timber cover profile
Mullion section/transom section
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
100
Cover profile fixation 80 167005
pc(s)
500
Base profile carrier 50 168405
pc(s)
SI-0004 2017 43
THERM+ S-I
System sections 50 mm
44 2017 SI-0024
THERM+ S-I
System sections 50 mm
System sections
THERM+ S-I
Pressure profile options with visible screw connection
Mullion section
SI-0025 2017 45
THERM+ S-I
System sections 50 mm
■ Gaskets
Article No. PU
Gasket for pressure
220205 100 m
profile 2/16
■ Accessories
Article No. PU
Pan head tapping screw 100
012110
5.5x32 pc(s)
Flat fillister head screw 100
012138
5.5x30 with sealing ring pc(s)
Flat fillister head screw 100
012139
5.5x40 with sealing ring pc(s)
Pan head tapping screw 100
012173
5.5x32 with sealing ring pc(s)
Flat fillister head screw
100
5.5x40 with sealing 012239
pc(s)
washer
Flat fillister head screw 100
012312
5.5x40 with sealing ring pc(s)
100
Cover 11 S 014110
pc(s)
46 2017 SI-0026
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Certified passive house curtain wall with insulating block PH and interior gasket D
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 D 150107 20 m
Gasket for transom 56 D 150112 20 m
Insulating block PH 56/29 168519 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012124
5.5x62 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 47 to 48 162090 10 pc(s)
012049
SI-0153 2017 47
THERM+ S-I
System sections 56 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Insulating block PH 56/29 168519 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012124
screw 5.5x62 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 47 to 48 162090 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
012049
48 2017 SI-0137
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Certified passive house curtain wall with insulating block PH and interior gasket L
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 L 150106 20 m
Gasket for transom 56 L 150111 20 m
Insulating block PH 56/29 168519 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012124
screw 5.5x62 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 47 to 48 162090 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
012049
SI-0154 2017 49
THERM+ S-I
System sections 56 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
26 - 64 mm
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 23 to 24 162030 10 pc(s)
26 - 64 mm
500
Base profile carrier 56 168410
pc(s)
50 2017 SI-0093
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Insulating block 21 and standard interior gasket
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Insulating block 56/21 150610 50 m
■ Accessories
26 - 64 mm
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012114
screw 5.5x42 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 27 to 28 162040 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
26 - 64 mm
012049
SI-0095 2017 51
THERM+ S-I
System sections 56 mm
■ Gaskets
Article No. PU
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Insulating block 56/9 151020 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
012049
52 2017 SI-0040b
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Standard exterior gasket
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
012049
SI-0030b 2017 53
THERM+ S-I
System sections 56 mm
90°
Steel curtain wall
Corner mullion 90°, vertical
Mullion section
■ Profiles
Article No. PU
Cover profile 56/15 013023 6m
Pressure profile 53
118010 6m
punched
Base profile 129005 6m
Connection profile 38/22 168121 6m
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Pan head tapping
012113 100 pc(s)
screw 5.5x40
Base profile carrier 56 168410 500 pc(s)
Special countersunk
908118 100 pc(s)
sheet metal screw 4.8x19
54 2017 SI-0176
THERM+ S-I
System sections 56 mm
90°
Steel curtain wall
System sections
THERM+ S-I
Corner mullion 90°, vertical
Mullion section
■ Profiles
Article No. PU
Cover profile 56/15 013023 6m
Pressure profile 53
118010 6m
punched
Base profile 129005 6m
Connection profile 38/22 168121 6m
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Pan head tapping
012113 100 pc(s)
screw 5.5x40
Base profile carrier 56 168410 500 pc(s)
Special countersunk
908118 100 pc(s)
sheet metal screw 4.8x19
SI-0178 2017 55
THERM+ S-I
System sections 56 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 D 150107 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Special countersunk 100
908118
sheet metal screw 4.8x19 pc(s)
56 2017 SI-0179
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Overview structural T-profiles
Mullion section
Wall
Surface Weight Height
No. thickn.
area m2 kg/m mm
mm
062010 0.230 7.20 60 8
062020 0.290 9.08 90 8
062030 0.350 13.49 120 10
ST-0001 2017 57
THERM+ S-I
System sections 56 mm
■ Gaskets
Article No. PU
Gasket for
011070.LI 100 m
pressure profile 3
Gasket for
011070.RE 100 m
pressure profile 3
Gasket for transom 56
012049
150115 20 m
with flap
Gasket for transom 56 L
150116 20 m
with flap
Gasket for transom 56 D
150117 20 m
with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
012049 plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
012049
58 2017 SI-0031
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Continuous base gasket with flap
Transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
012049 Compensation gasket 2 011080 100 m
Base gasket for transom
150120 20 m
56 with flap
Base gasket for transom
150121 20 m
56 L with flap
Base gasket for transom
150122 20 m
56 D with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
012049
Sealing piece 100
152015
for transom 56 pc(s)
Sealing piece
152071 10 pc(s)
for base transom
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
012049
SI-0031a 2017 59
THERM+ S-I
System sections 56 mm
■ Accessories
Article No. PU
Special countersunk 100
012049
Alternativ sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
100
Terminal clamp 48/20 915501
pc(s)
012049
60 2017 SI-0183
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Galvanized structures
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
012049
SI-0030a 2017 61
THERM+ S-I
System sections 56 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012114
screw 5.5x42 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister head 100
908952
screw M5x10 pc(s)
100
Special blind rivet 4.8x15 910125
pc(s)
62 2017 SI-0130
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Interior compensation of varying infill thicknesses
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure prof. 3 011070.LI 100 m
Gasket for pressure prof. 3 011070.RE 100 m
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Interior gasket 3 220320 100 m
■ Accessories
Article No. PU
Pan head tapping
012091 100 pc(s)
screw 5.5x16
Pan head tapping
012116 100 pc(s)
screw 5.5x48
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece
152015 100 pc(s)
for transom 56
Glass carrier 33 to 34 162055 10 pc(s)
Base profile carrier 56 168410 500 pc(s)
Fixture spring 26/25/10 915015 50 pc(s)
SI-0035a 2017 63
THERM+ S-I
System sections 56 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012107
screw 5.5x25 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 10 to 14 162005 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
012049
64 2017 SI-0035
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Polygon glazing system with standard interior gasket 1° to 7°
Mullion section exterior angle/interior angle
■ Accessories
Article No. PU
Pan head tapping 100
012114
screw 5.5x42 pc(s)
500
Base profile carrier 56 168410
pc(s)
SI-0048 2017 65
THERM+ S-I
System sections 56 mm
■ Accessories
Article No. PU
Pan head tapping 100
012114
screw 5.5x42 pc(s)
500
Base profile carrier 56 168410
pc(s)
66 2017 SI-0128
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Polygon glazing system 8° to 20° and 21° to 33° with polygon interior and exterior gasket
Mullion section exterior angle
■ Gaskets
Article No. PU
Gasket for pressure
011805 100 m
profile 5 polygonal
Gasket for mullion 56
150140 20 m
polygonal 8° to 20°
Gasket for mullion 56
150145 20 m
polygonal 21° to 33°
■ Accessories
Article No. PU
Pan head tapping 100
012117
screw 5.5x50 pc(s)
Pan head tapping 100
012118
screw 5.5x52 pc(s)
500
Base profile carrier 56 168410
pc(s)
SI-0049 2017 67
THERM+ S-I
System sections 56 mm
■ Gaskets
Article No. PU
Gasket for pressure
011805 100 m
profile 5 polygonal
Gasket for mullion 56
150150 20 m
polygonal 34° to 45°
■ Accessories
Article No. PU
Pan head tapping
012119 100 pc(s)
screw 5.5x55
Base profile carrier 56 168410 500 pc(s)
68 2017 SI-0050
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Flat pressure profile options for polygon glazing system 3° to 7° with standard interior gasket
Mullion section exterior angle
SI-0158 2017 69
THERM+ S-I
System sections 56 mm
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
100
Cover profile fixation 80 167005
pc(s)
500
Base profile carrier 56 168410
pc(s)
70 2017 SI-0034
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Snap-on cover profile options
Mullion section
SI-0054 2017 71
THERM+ S-I
System sections 56 mm
72 2017 SI-0055
THERM+ S-I
System sections 56 mm
System sections
THERM+ S-I
Flat pressure profile options
Mullion section
■ Gaskets
Article No. PU
Gasket for pressure
220205 100 m
profile 2/16
■ Accessories
Article No. PU
Pan head tapping screw 100
012110
5.5x32 pc(s)
Flat fillister head screw 100
012138
5.5x30 with sealing ring pc(s)
Flat fillister head screw 100
012139
5.5x40 with sealing ring pc(s)
Pan head tapping screw 100
012173
5.5x32 with sealing ring pc(s)
Flat fillister head screw
100
5.5x40 with sealing 012239
pc(s)
washer
Flat fillister head screw 100
012312
5.5x40 with sealing ring pc(s)
100
Cover 11 S 014110
pc(s)
SI-0035c 2017 73
THERM+ S-I
System sections 76 mm
■ Gaskets
Article No. PU
Gasket for pressure
011073 100 m
profile 5
Gasket for mullion 76 D 150207 20 m
Gasket for transom 76 D 150212 20 m
Insulating block P 76/39 168526 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Cross point sealing
016056 10 pc(s)
plate 76 P
Sealing piece 100
152020
for transom 76 pc(s)
Sealing piece
152421 10 pc(s)
for pressure profile 76/5
Glass carrier 43 to 44 162080 10 pc(s)
012049
74 2017 SI-0155
THERM+ S-I
System sections 76 mm
System sections
THERM+ S-I
Certified passive house curtain wall with insulating block P 76/39 and interior gasket S
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011073 100 m
profile 5
Gasket for mullion 76 150205 20 m
Gasket for transom 76 150210 20 m
Insulating block P 76/39 168526 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012129
5.5x58 pc(s)
Cross point sealing
016056 10 pc(s)
plate 76 P
Sealing piece 100
152020
for transom 76 pc(s)
Sealing piece
152421 10 pc(s)
for pressure profile 76/5
Glass carrier 43 to 44 162080 10 pc(s)
500
Base profile carrier 76 168415
pc(s)
012049
SI-0103 2017 75
THERM+ S-I
System sections 76 mm
■ Gaskets
Article No. PU
Gasket for pressure
011073 100 m
profile 5
Gasket for mullion 76 L 150206 20 m
Gasket for transom 76 150210 20 m
Insulating block P 76/39 168526 50 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012129 100 pc(s)
5.5x58
Cross point sealing
016056 10 pc(s)
plate 76 P
Sealing piece
152020 100 pc(s)
for transom 76
Sealing piece
152421 10 pc(s)
for pressure profile 76/5
Glass carrier 43 to 44 162080 10 pc(s)
Base profile carrier 76 168415 500 pc(s)
012049
76 2017 SI-0156
THERM+ S-I
System sections 76 mm
System sections
THERM+ S-I
Insulating block P 76/19 and standard interior gasket
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 76 150205 20 m
Gasket for transom 76 150210 20 m
Insulating block P 76/19 168521 50 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012113 100 pc(s)
5.5x40
Sealing piece
014037 10 pc(s)
for pressure profile 76
Crosspoint sealing
016052 10 pc(s)
plate 76
Sealing piece
152020 100 pc(s)
for transom 76
Glass carrier 25 to 26 162035 10 pc(s)
Base profile carrier 76 168415 500 pc(s)
012049
SI-0101 2017 77
THERM+ S-I
System sections 76 mm
■ Gaskets
Article No. PU
Gasket for mullion 76 150205 20 m
Gasket for transom 76 150210 20 m
Insulating block 76/9 151030 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012113
5.5x40 pc(s)
Sealing piece
014037 10 pc(s)
for pressure profile 76
Crosspoint sealing
016052 10 pc(s)
plate 76
Sealing piece 100
152020
for transom 76 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 76 168415
pc(s)
012049
78 2017 SI-0065
THERM+ S-I
System sections 76 mm
System sections
THERM+ S-I
Standard exterior gasket
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 76 150205 20 m
Gasket for transom 76 150210 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012113
5.5x40 pc(s)
Sealing piece
014037 10 pc(s)
for pressure profile 76
Crosspoint sealing
016052 10 pc(s)
plate 76
Sealing piece 100
152020
for transom 76 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 76 168415
pc(s)
012049
SI-0060 2017 79
THERM+ S-I
System sections 76 mm
90°
Steel curtain wall
Corner mullion 90°, vertical
Mullion section
■ Profiles
Article No. PU
Cover profile 76/15 013050 6m
Pressure prof. 73 punched 118015 6m
Base profile 129005 6m
Connection profile 49/22 168126 6m
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 76 150205 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Pan head tapping screw
012113 100 pc(s)
5.5x40
Base profile carrier 76 168415 500 pc(s)
Special countersunk
908118 100 pc(s)
sheet metal screw 4.8x19
80 2017 SI-0177
THERM+ S-I
System sections 76 mm
System sections
THERM+ S-I
Corner mullion for variable angles, vertical
Mullion section
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 76 D 150207 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Pan head tapping screw 100
012113
5.5x40 pc(s)
Special countersunk sheet 100
908118
metal screw 4.8x19 pc(s)
SI-0180 2017 81
THERM+ S-I
System sections 76 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for transom 76
150215 20 m
with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012113
5.5x40 pc(s)
Sealing piece
014037 10 pc(s)
for pressure profile 76
Crosspoint sealing
016052 10 pc(s)
plate 76
Sealing piece 100
152020
for transom 76 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 76 168415
pc(s)
012049
82 2017 SI-0061
THERM+ S-I
System sections 76 mm
System sections
THERM+ S-I
Continuous base gasket with flap
Transom section
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Compensation gasket 2 011080 100 m
Base gasket for transom
150220 20 m
76 with flap
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012113 100 pc(s)
5.5x40
Sealing piece
014037 10 pc(s)
for pressure profile 76
Crosspoint sealing
016052 10 pc(s)
plate 76
Sealing piece
152020 100 pc(s)
for transom 76
Sealing piece for base
152071 10 pc(s)
transom
Glass carrier 25 to 26 162035 10 pc(s)
Base profile carrier 76 168415 500 pc(s)
012049
SI-0062 2017 83
THERM+ S-I
System sections 76 mm
■ Accessories
Alternative
Article No. PU
Pan head tapping screw
012113 100 pc(s)
5.5x40
Base profile carrier 76 168415 500 pc(s)
Terminal clamp 48/20 915501 100 pc(s)
84 2017 SI-0184
THERM+ S-I
System sections 76 mm
System sections
THERM+ S-I
Galvanized structures
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 76 150205 20 m
Gasket for transom 76 150210 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012113
5.5x40 pc(s)
Sealing piece
014037 10 pc(s)
for pressure profile 76
Crosspoint sealing
016052 10 pc(s)
plate 76
Sealing piece 100
152020
for transom 76 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
500
Base profile carrier 76 168415
pc(s)
012049
SI-0060a 2017 85
THERM+ S-I
System sections 76 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 76 150205 20 m
Gasket for transom 76 150210 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012114 100 pc(s)
5.5x42
Sealing piece
014037 10 pc(s)
for pressure profile 76
Crosspoint sealing
016052 10 pc(s)
plate 76
Sealing piece
152020 100 pc(s)
for transom 76
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister head
908952 100 pc(s)
screw M5x10
Special blind rivet 4.8x15 910125 100 pc(s)
86 2017 SI-0131
THERM+ S-I
System sections 76 mm
System sections
THERM+ S-I
Interior compensation of varying infill thicknesses
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 76 150205 20 m
Gasket for transom 76 150210 20 m
Interior gasket 3 220320 100 m
■ Accessories
Article No. PU
Pan head tapping screw
012091 100 pc(s)
5.5x16
Pan head tapping screw
012116 100 pc(s)
5.5x48
Sealing piece
014037 10 pc(s)
for pressure profile 76
Crosspoint sealing
016052 10 pc(s)
plate 76
Sealing piece
152020 100 pc(s)
for transom 76
Glass carrier 33 to 34 162055 10 pc(s)
Base profile carrier 76 168415 500 pc(s)
Fixture spring 39/25/10 915020 50 pc(s)
SI-0064 2017 87
THERM+ S-I
System sections 76 mm
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 76 150205 20 m
Gasket for transom 76 150210 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012107
5.5x25 pc(s)
Sealing piece
014037 10 pc(s)
for pressure profile 76
Crosspoint sealing
016052 10 pc(s)
plate 76
Sealing piece 100
152020
for transom 76 pc(s)
Glass carrier 10 to 14 162005 10 pc(s)
500
Base profile carrier 76 168415
pc(s)
012049
88 2017 SI-0063
THERM+ S-I
System sections 76 mm
System sections
THERM+ S-I
Polygon glazing system with standard interior gasket 1° to 7°
Mullion section exterior angle/interior angle
■ Accessories
Article No. PU
Pan head tapping screw 100
012113
5.5x40 pc(s)
500
Base profile carrier 76 168415
pc(s)
SI-0069 2017 89
THERM+ S-I
System sections 76 mm
■ Accessories
Article No. PU
Base profile carrier 76 168415 500 pc(s)
90 2017 SI-0108
THERM+ S-I
System sections 76 mm
System sections
THERM+ S-I
Flat pressure profile options for polygon glazing system 3° to 7° with standard interior gasket
Mullion section exterior angle
SI-0159 2017 91
THERM+ S-I
System sections 76 mm
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012113
5.5x40 pc(s)
Sealing piece
014037 10 pc(s)
for pressure profile 76
Crosspoint sealing plate
016052 10 pc(s)
76
Sealing piece 100
152020
for transom 76 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
100
Cover profile fixation 80 167005
pc(s)
500
Base profile carrier 76 168415
pc(s)
92 2017 SI-0066
THERM+ S-I
System sections 76 mm
System sections
THERM+ S-I
Snap-on cover profile options
Mullion section 76 mm
SI-0071 2017 93
THERM+ S-I
System sections 76 mm
■ Gaskets
Article No. PU
Gasket for pressure
220205 100 m
profile 2/16
■ Accessories
Article No. PU
Pan head tapping screw 100
012110
5.5x32 pc(s)
Flat fillister head screw 100
012138
5.5x30 with sealing ring pc(s)
Flat fillister head screw 100
012139
5.5x40 with sealing ring pc(s)
Pan head tapping screw 100
012173
5.5x32 with sealing ring pc(s)
Flat fillister head screw
100
5.5x40 with sealing 012239
pc(s)
washer
Flat fillister head screw 100
012312
5.5x40 with sealing ring pc(s)
100
Cover 11 S 014110
pc(s)
94 2017 SI-0157
THERM+ S-I
System sections 96 mm
System sections
THERM+ S-I
Steel add-on construction with mounting options for aluminium base profiles
Mullion section/transom section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 96 150705 20 m
Gasket for transom 96 150710 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012114
5.5x42 pc(s)
Sealing piece
152425 10 pc(s)
for pressure profile 96
Glass carrier 25 to 26 162035 10 pc(s)
Cross point sealing
167480 10 pc(s)
plate 96
Special flat fillister head 100
908952
screw M5x10 pc(s)
100
Special blind rivet 4.8x15 910125
pc(s)
SI-0008 2017 95
THERM+ S-I
Building connections 50/56/76 mm
■ Technical information
– T129 = Vapour-tight membrane no. 951019.
96 2017 SI-1050
THERM+ S-I
Building connections 50/56/76 mm
System sections
THERM+ S-I
Wall connection with ventilated façade panelling
■ Technical information
– T128 = Breather membrane no. 951029.
– T129 = Vapour-tight membrane no. 951019.
– T251 = Make provision for insect screen.
SI-1051 2017 97
THERM+ S-I
Structural glazing SG2
■ Technical information
– Approval required in individual cases.
– T129 = Vapour-tight membrane no. 951019.
98 2017 SI-1063
THERM+ S-I
Building connections 50/56/76 mm
System sections
THERM+ S-I
Base connection with drainage to the front
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– T126 = Vapour-tight membrane no. 951021.
– T249 = Execution vapour-tight or as breather membrane
depending on installation-site.
– T250 = Insulation with mineral cotton when required.
– T257 = Console profile no. 146005, finished.
SI-1053 2017 99
THERM+ S-I
Building connections 50/56/76 mm
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– T126 = Vapour-tight membrane no. 951021.
– T249 = Execution vapour-tight or as breather membrane
depending on installation-site.
– T250 = Insulation with mineral cotton when required.
– T251 = Make provision for insect screen.
– T257 = Console profile
no. 146005, finished.
System sections
THERM+ S-I
Ceiling connection as non-locating bearing
■ Technical information
– T126 = Vapour-tight membrane no. 951021.
– T257 = Console profile no. 146005, finished.
■ Technical information
– T126 = Vapour-tight membrane no. 951021.
– T257 = Console profile no. 146005, finished.
System sections
THERM+ S-I
Ceiling connection as non-locating bearing with ventilated façade panelling
■ Technical information
– T126 = Vapour-tight membrane no. 951021.
– T251 = Make provision for insect screen.
– T252 = Breather membrane no. 951031.
– T257 = Console profile no. 146005, finished.
■ Technical information
– *Mask joint of mullion-transom or
carry out vapour-tight.
– Pressure relief of the region behind
the panel by cuttings in the mullion gasket.
– T30 = Notching.
– T129 = Vapour-tight membrane no. 951019.
– T254 = Seal joints.
System sections
THERM+ S-I
Intermediate ceiling with inserted construction (interrupted mullion) and panel joint
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– Pressure relief of the region behind the
panel by cuttings in the mullion gasket.
– Stabilisation of the panel in the upper region when required.
– T30 = Notching.
– T129 = Vapour-tight membrane no. 951019.
– T252 = Breather membrane no. 951031.
– T253 = Insulation with non-flammable mineral-cotton.
– T254 = Seal joints.
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– Pressure relief of the region behind the panel
by cuttings in the mullion gasket.
– T30 = Notching.
– T129 = Vapour-tight membrane no. 951019.
System sections
THERM+ S-I
Intermediate ceiling with exposed curtain wall (continuous mullion) as fixed bearing
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– Pressure relief of the region behind the panel
by cuttings in the mullion gasket.
– T30 = Notching.
– T129 = Vapour-tight membrane no. 951019.
■ Technical information
– T126 = Vapour-tight membrane no. 951021.
– T251 = Make provision for insect screen.
– T252 = Breather membrane no. 951031.
– T257 = Console profile no. 146005, finished.
System sections
THERM+ S-I
Attic with inserted curtain wall and ventilated façade panelling
■ Technical information
– T124 = Breather
membrane.
– T126 = Vapour-tight
membrane
no. 951021.
– T251 = Make provision
for insect screen.
– T252 = Breather
membrane
no. 951031.
– T257 = Console profile
no. 146005,
finished.
Add-ons
THERM+ S-I
Burglar prevention
Add-ons
System benfits 113
Sections resistance class RC2 115
Sections resistance class RC3 136
Screw selection RC2/RC3 153
Fire protection
System benefits 163
Sections fire protection 165
Screw selection 171
Selection glass carriers 173
Filling elements 174
Panel options 175
Technical execution and assembly 177
Structural Glazing
System benefits 179
Sections Structural Glazing SG2 181
Exterior sealing 184
Screw selection 187
Selection insulating block 191
Selection glass carriers 192
Suction discs 193
Indications for the execution of silicone joints 195
2017 111
112 2017
THERM+ S-I
System benefits
THERM+ S-I
Add-ons
- RC2:
- Pressure-resistant blocking of the glass by a special
building component.
- Screw locking with bullet for screw heads, protection insert
or by drilling out the screw drive.
- Minimum glazing class P4A.
RC3:
- Pressure-resistant blocking of the glass by a special
building component.
- Screw locking with bullet for screw heads, protection insert
or by drilling out the screw drive.
- Reinforced screwing in the screw channel.
- Minimum glazing class P5A.
– Only few additional components.
– No visual difference between the variations.
– A huge selection of pressure and cover profiles.
– System widths and infill thicknesses identical to the basic system.
– For rooflight glazing.
– Simple and efficient assembly.
– Extension by the use of insertion elements of FRAME+ and WING.
THERM+ S-I
Add-ons
– Glazing class P4A. Cover profile 50/15 013003 6m
– For pressure-resistant blocking of the glass unit Cover profile 50/20 013210 6m
see Processing.
Pressure prof. 47 punched 118005 6m
– Screw locking with bullet, alternatively pan head tapping
Base profile 129005 6m
screw with protection insert or by drilling out the screw drive.
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 L 150006 20 m
Gasket for transom 50 L 150011 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012092
5.5x19 pc(s)
Flat fillister head screw 100
012154
5.5x45 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
100
Bullet for screw heads 014060
pc(s)
Crossp. sealing plate 50 016050 10 pc(s)
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 29 to 30 162045 10 pc(s)
100
Back filling 60/17 167015
pc(s)
500
Base profile carrier 50 168405
pc(s)
012049
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for transom 50 L
150016 20 m
with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012092
5.5x19 pc(s)
Flat fillister head screw 100
012154
5.5x45 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
100
Bullet for screw heads 014060
pc(s)
Crossp. sealing plate 50 016050 10 pc(s)
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 29 to 30 162045 10 pc(s)
100
Back filling 60/17 167015
pc(s)
500
Base profile carrier 50 168405
pc(s)
THERM+ S-I
Add-ons
– Glazing class P4A. Cover profile 50/15 013003 6m
– For pressure-resistant blocking of the glass unit Pressure prof. 47 punched 118005 6m
see Processing.
Base profile 129005 6m
– Screw locking with bullet, alternatively pan head tapping
Connection profile 36/22 168005 6m
screw with protection insert or by drilling out the screw drive.
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for pressure
011076 100 m
profile 6
Base gasket for transom
150021 20 m
50 L with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Flat fillister head screw 100
012154
5.5x45 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
100
Bullet for screw heads 014060
pc(s)
Crossp.sealing plate 50 016050 10 pc(s)
Sealing piece 100
152010
for transom 50 pc(s)
Sealing piece for base
152070 10 pc(s)
transom
Glass carrier 29 to 30 162045 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012155 100 pc(s)
5.5x48
Sealing piece
014035 10 pc(s)
for pressure profile 50
Bullet for screw heads 014060 100 pc(s)
150006
Crossp. sealing plate 50 016050 10 pc(s)
Sealing piece
152010 100 pc(s)
for transom 50
Glass carrier 29 to 30 162045 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Spec. flat fillister
908952 100 pc(s)
head screw M5x10
Special blind rivet 4.8x15 910125 100 pc(s)
Alternativ
Alternative
THERM+ S-I
Add-ons
– Glazing class P4A.
Cover profile 50/15 013003 6m
– For pressure-resistant blocking of the glass unit see Processing.
Pressure profile 47
– Screw locking with bullet, alternatively pan head tapping screw 118005 6m
punched
with protection insert or by drilling out the screw drive. Base profile 129005 6m
– With exterior gasket for pressure profile 5 mm and
Base profile 50/56/76 168400 200 m
standard interior gasket up to max. 7°.
– Face width of cover profile depends on angle and infill thickness.
■ Gaskets
– Glass bite (A and B) must be min. 12 mm. The distance
between glass edge and gasket cap (C) has to be min. 3 mm. Article No. PU
Please note the glass tolerances! Gasket for pressure
011073 100 m
– T-connectors are to be coordinated with RAICO. profile 5
– The length of the pressure profile screws is to be determined graphically. Gasket for mullion 50 L 150006 20 m
■ Accessories
Article No. PU
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012155 100 pc(s)
5.5x48
Bullet for screw heads 014060 100 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 50 168405 500 pc(s)
THERM+ S-I
Add-ons
– Glazing class P4A.
Pressure profile 50/12 013007 6m
– For pressure-resistant blocking of the glass unit
Pressure profile 50/9 013008 6m
see Processing.
– Screw locking with bullet, alternatively pan head tapping Pressure profile 50/25 013014 6m
screw with protection insert or by drilling out the screw drive. Pressure profile 50/3 013300 6m
– For more pressure profiles see Product range.
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 56 L 150106 20 m
Gasket for transom 56 L 150111 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012092
5.5x19 pc(s)
Flat fillister head screw 100
012154
5.5x45 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
100
Bullet for screw heads 014060
pc(s)
Crossp. sealing plate 56 016051 10 pc(s)
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 29 to 30 162045 10 pc(s)
100
Back filling 60/17 167015
pc(s)
500
Base profile carrier 56 168410
pc(s)
012049
THERM+ S-I
Add-ons
– Glazing class P4A.
Cover profile 56/15 013023 6m
– For pressure-resistant blocking of the glass unit
Pressure profile 53
see Processing. 118010 6m
punched
– Screw locking with bullet, alternatively pan head tapping Base profile 129005 6m
screw with protection insert or by drilling out the screw drive.
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for transom 56 L
150116 20 m
with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Pan head tapping screw 100
012092
5.5x19 pc(s)
Flat fillister head screw 100
012154
5.5x45 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
100
Bullet for screw heads 014060
pc(s)
Crossp. sealing plate 56 016051 10 pc(s)
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 29 to 30 162045 10 pc(s)
100
Back filling 60/17 167015
pc(s)
500
Base profile carrier 56 168410
pc(s)
012049
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for pressure
011076 100 m
profile 6
Base gasket for transom
150121 20 m
56 L with flap
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012129 100 pc(s)
5.5x58
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014036 10 pc(s)
for pressure profile 56
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 56 016051 10 pc(s)
Sealing piece
152015 100 pc(s)
for transom 56
Sealing piece for base
152070 10 pc(s)
transom
Glass carrier 29 to 30 162045 10 pc(s)
Base profile carrier 56 168410 500 pc(s)
THERM+ S-I
– Glazing class P4A.
Add-ons
Cover profile 56/15 013023 6m
– For pressure-resistant blocking of the glass unit see Processing.
Cover profile 56/20 013410 6m
– Screw locking with bullet, alternatively pan head tapping screw
with protection insert or by drilling out the screw drive. Pressure prof. 53 punched 118010 6m
– Stainless steel nails for add-on construction and related Base profile 47 punched 145010 6m
accessories have to be ordered at HILTI. Base profile 47 145011 6m
– German general approval DIBT Berlin, Z-14.4-766. Base profile 56 145014 6m
– Minimum wall thickness for HILTI fastener: 4 mm.
– Minimum wall thickness for rivets and screws: 2 mm. ■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fill. head screw 5.5x48 012155 100 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 56 016051 10 pc(s)
Sealing piece
152015 100 pc(s)
for transom 56
Glass carrier 29 to 30 162045 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Special flat fillister head
908952 100 pc(s)
screw M5x10
Special blind rivet 4,8x15 910125 100 pc(s)
Alternativ
Alternative
■ Accessories
Article No. PU
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012155 100 pc(s)
5.5x48
Bullet for screw heads 014060 100 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 56 168410 500 pc(s)
THERM+ S-I
Add-ons
– Glazing class P4A.
Cover profile 56/15 013023 6m
– For pressure-resistant blocking of the glass unit
Cover profile 56/12 013024 6m
see Processing.
– Screw locking with bullet, alternatively pan head tapping Cover profile 56/25 013025 6m
screw with protection insert or by drilling out the screw drive. Cover profile 56/25 013400 6m
– Slipping down of the cover profiles must be prevented. Cover profile 56/20 013410 6m
– For more cover profiles, end caps and belay sheet Pressure profile 53
see Product range. 118010 6m
punched
Cover profile 56/13.5 141301 6m
Cover profile 56/25 141304 6m
Cover profile 56/32 141307 6m
THERM+ S-I
Add-ons
– Glazing class P4A.
Cover profile 76/15 013050 6m
– For pressure-resistant blocking of the glass unit
Cover profile 76/20 013610 6m
see Processing.
– Screw locking with bullet, alternatively pan head tapping Pressure prof. 73 punched 118015 6m
screw with protection insert or by drilling out the screw drive. Base profile 129005 6m
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 76 150205 20 m
Gasket for transom 76 150210 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014037 10 pc(s)
for pressure profile 76
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 76 016052 10 pc(s)
Sealing piece
152020 100 pc(s)
for transom 76
Glass carrier 29 to 30 162045 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 76 168415 500 pc(s)
012049
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for transom 76
150215 20 m
with flap
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece for pressu-
014037 10 pc(s)
re profile 76
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 76 016052 10 pc(s)
Sealing piece
152020 100 pc(s)
for transom 76
Glass carrier 29 to 30 162045 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 76 168415 500 pc(s)
012049
THERM+ S-I
Add-ons
– Glazing class P4A.
Cover profile 76/15 013050 6m
– For pressure-resistant blocking of the glass unit
Pressure prof. 73 punched 118015 6m
see Processing.
– Screw locking with bullet, alternatively pan head tapping Base profile 129005 6m
screw with protection insert or by drilling out the screw drive. Connection profile 36/22 168005 6m
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for press. prof. 6 011076 100 m
Base gasket for transom
150220 20 m
76 with flap
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014037 10 pc(s)
for pressure profile 76
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 76 016052 10 pc(s)
Sealing piece
152020 100 pc(s)
for transom 76
Sealing piece
152071 10 pc(s)
for base transom
Glass carrier 29 to 30 162045 10 pc(s)
Base profile carrier 76 168415 500 pc(s)
012049
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012155 100 pc(s)
5.5x48
Sealing piece
014037 10 pc(s)
for pressure profile 76
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 76 016052 10 pc(s)
Sealing piece
152020 100 pc(s)
for transom 76
Glass carrier 29 to 30 162045 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Special flat fillister head
908952 100 pc(s)
screw M5x10
Special blind rivet 4,8x15 910125 100 pc(s)
THERM+ S-I
– Glazing class P4A.
Add-ons
Cover profile 76/15 013050 6m
– For pressure-resistant blocking of the glass unit see Processing.
– Screw locking with bullet, alternatively pan head tapping screw Pressure profile 73
118015 6m
with protection insert or by drilling out the screw drive. punched
– With exterior gasket for pressure profile 5 mm and standard Base profile 129005 6m
interior gasket up to max. 7°.
Base profile 50/56/76 168400 200 m
– Face width of cover profile depends on angle and infill thickness.
– Glass bite (A and B) must be min. 15 mm. The distance between glass edge
and gasket cap (C) has to be min. 3 mm. Please note the glass tolerances! ■ Gaskets
– T-connectors are to be coordinated with RAICO. Article No. PU
– The length of the pressure profile screws is to be determined graphically. Gasket for pressure
011073 100 m
profile 5
Gasket for mullion 76 150205 20 m
■ Accessories
Article No. PU
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012155 100 pc(s)
5.5x48
Bullet for screw heads 014060 100 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 76 168415 500 pc(s)
– For more cover profiles, end caps and belay sheet Cover profile 76/25 141505 6m
see Product range.
THERM+ S-I
Add-ons
– Glazing class P4A.
Pressure profile 76/3 013313 6m
– For pressure-resistant blocking of the glass unit
see Processing.
– Screw locking with bullet or by drilling out the screw drive.
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 50 L 150006 20 m
Gasket for transom 50 L 150011 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014035 10 pc(s)
for pressure profile 50
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 50 016050 10 pc(s)
Sealing piece
152010 100 pc(s)
for transom 50
Glass carrier 31 to 32 162050 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 50 168405 500 pc(s)
012049
THERM+ S-I
Add-ons
– Glazing class P5A.
Cover profile 50/15 013003 6m
– For pressure-resistant blocking of the glass unit
Reinforcement
see Processing. 013111 6m
for pressure profile 40
– Screw distance of pressure profile reinforcement: 125 mm. Pressure prof. 47 punched 118005 6m
– Screw locking with bullet, alternatively pan head tapping
Base profile RC 129010 6m
screw with protection insert or by drilling out the screw drive.
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for transom 50 L
150016 20 m
with flap
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014035 10 pc(s)
for pressure profile 50
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 50 016050 10 pc(s)
Sealing piece
152010 100 pc(s)
for transom 50
Glass carrier 31 to 32 162050 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 50 168405 500 pc(s)
012049
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for pressure
011074 100 m
profile 7
Base gasket for transom
150021 20 m
50 L with flap
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014035 10 pc(s)
for pressure profile 50
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 50 016050 10 pc(s)
Sealing piece
152010 100 pc(s)
for transom 50
Sealing piece for base
152070 10 pc(s)
transom
Glass carrier 31 to 32 162050 10 pc(s)
Base profile carrier 50 168405 500 pc(s)
THERM+ S-I
– Glazing class P5A.
Add-ons
Cover profile 50/15 013003 6m
– For pressure-resistant blocking of the glass unit see Processing.
Reinforcement
– Screw distance of pressure profile reinforcement: 125 mm. 013111 6m
for pressure profile 40
– Screw locking with bullet, alternatively pan head tapping screw
Pressure profile 47
with protection insert or by drilling out the screw drive. 118005 6m
punched
– With exterior gasket for pressure profile 5 mm and standard
interior gasket up to max. 7°. Base profile RC 129010 6m
– Face width of cover profile depends on angle and infill thickness. Base profile 50/56/76 168400 200 m
– Glass bite (A and B) must be min. 12 mm. The distance between glass edge
and gasket cap (C) has to be min. 3 mm. Please note the glass tolerances! ■ Gaskets
– T-connectors are to be coordinated with RAICO.
Article No. PU
– The length of the pressure profile screws is to be determined graphically.
Gasket for pressure
011073 100 m
profile 5
Gasket for mullion 50 150005 20 m
■ Accessories
Article No. PU
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012156 100 pc(s)
5.5x50
Bullet for screw heads 014060 100 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 50 168405 500 pc(s)
THERM+ S-I
Add-ons
– Glazing class P5A.
Pressure profile 50/12 013007 6m
– For pressure-resistant blocking of the glass unit
Pressure profile 50/9 013008 6m
see Processing.
– Screw distance of pressure profile reinforcement: 125 mm. Pressure profile 50/25 013014 6m
– Screw locking with bullet or by drilling out the screw drive.
– For more pressure profiles see Product range.
– T195 = Stainless steel flat (t = 2 mm) own production.
■ Gaskets
012154 Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 56 L 150106 20 m
Gasket for transom 56 L 150111 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014036 10 pc(s)
for pressure profile 56
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 56 016051 10 pc(s)
Sealing piece
152015 100 pc(s)
for transom 56
Glass carrier 31 to 32 162050 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 56 168410 500 pc(s)
012154
012049
THERM+ S-I
Add-ons
– Glazing class P5A.
Cover profile 56/15 013023 6m
– For pressure-resistant blocking of the glass unit
Reinforcement
see Processing. 013111 6m
for pressure profile 40
– Screw distance of pressure profile reinforcement: 125 mm. Pressure prof. 53 punched 118010 6m
– Screw locking with bullet, alternatively pan head tapping
Base profile RC 129010 6m
screw with protection insert or by drilling out the screw drive.
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for transom 56 L
150116 20 m
with flap
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014036 10 pc(s)
for pressure profile 56
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 56 016051 10 pc(s)
Sealing piece
152015 100 pc(s)
for transom 56
Glass carrier 31 to 32 162050 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 56 168410 500 pc(s)
012154
012049
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for pressure
011074 100 m
profile 7
Base gasket for transom
150121 20 m
56 L with flap
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014036 10 pc(s)
for pressure profile 56
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 56 016051 10 pc(s)
Sealing piece
152070 10 pc(s)
for base transom
Glass carrier 31 to 32 162050 10 pc(s)
Base profile carrier 56 168410 500 pc(s)
THERM+ S-I
– Glazing class P5A.
Add-ons
Cover profile 56/15 013023 6m
– For pressure-resistant blocking of the glass unit see Processing.
Reinforcement
– Screw distance of pressure profile reinforcement: 125 mm. 013111 6m
for pressure profile 40
– Screw locking with bullet, alternatively pan head tapping screw Pressure profile 53
with protection insert or by drilling out the screw drive. 118010 6m
punched
– With exterior gasket for pressure profile 5 mm and standard Base profile RC 129010 6m
interior gasket up to max. 7°.
Base profile 50/56/76 168400 200 m
– Face width of cover profile depends on angle and infill thickness.
– Glass bite (A and B) must be min. 13 mm. The distance between glass edge
and gasket cap (C) has to be min. 3 mm. Please note the glass tolerances! ■ Gaskets
– T-connectors are to be coordinated with RAICO. Article No. PU
– The length of the pressure profile screws is to be determined graphically. Gasket for pressure
011073 100 m
profile 5
Gasket for mullion 56 150105 20 m
■ Accessories
Article No. PU
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012156 100 pc(s)
5.5x50
Bullet for screw heads 014060 100 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 56 168410 500 pc(s)
THERM+ S-I
Add-ons
– Glazing class P5A.
Pressure profile 56/12 013027 6m
– For pressure-resistant blocking of the glass unit
Pressure profile 56/9 013028 6m
see Processing.
– Screw distance of pressure profile reinforcement: 125 mm.
– Screw locking with bullet or by drilling out the screw drive.
– For more pressure profiles see Product range.
– T195 = Stainless steel flat (t = 2 mm) own production.
■ Gaskets
Article No. PU
Gasket for pressure
012154 011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 76 150205 20 m
Gasket for transom 76 150210 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014037 10 pc(s)
for pressure profile 76
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 76 016052 10 pc(s)
Sealing piece
152020 100 pc(s)
for transom 76
Glass carrier 31 to 32 162050 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 76 168415 500 pc(s)
012154
012049
THERM+ S-I
Add-ons
– Glazing class P5A.
Cover profile 76/15 013050 6m
– For pressure-resistant blocking of the glass unit
Pressure profile 73
see Processing. 118015 6m
punched
– Screw distance of pressure profile reinforcement: 125 mm. Base profile RC 129010 6m
– Screw locking with bullet, alternatively pan head tapping
Base profile 50/56/76 168400 200 m
screw with protection insert or by drilling out the screw drive.
– T195 = Stainless steel flat (t = 2 mm) own production.
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for transom 76
150215 20 m
with flap
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014037 10 pc(s)
for pressure profile 76
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 76 016052 10 pc(s)
Sealing piece
152020 100 pc(s)
for transom 76
Glass carrier 31 to 32 162050 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 76 168415 500 pc(s)
012154
012049
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Flat fillister head screw
012154 100 pc(s)
5.5x45
Sealing piece
014037 10 pc(s)
for pressure profile 76
Bullet for screw heads 014060 100 pc(s)
Crossp. sealing plate 76 016052 10 pc(s)
Sealing piece
152070 10 pc(s)
for base transom
Glass carrier 31 to 32 162050 10 pc(s)
Base profile carrier 76 168415 500 pc(s)
THERM+ S-I
– Glazing class P5A.
Add-ons
– For pressure-resistant blocking of the glass unit see Processing. Cover profile 76/15 013050 6m
– Screw distance of pressure profile reinforcement: 125 mm. Pressure profile 73
118015 6m
– Screw locking with bullet, alternatively pan head tapping screw punched
with protection insert or by drilling out the screw drive. Base profile RC 129010 6m
– With exterior gasket for pressure profile 5 mm and standard
interior gasket up to max. 7°. Base profile 50/56/76 168400 200 m
– Face width of cover profile depends on angle and infill thickness.
– Glass bite (A and B) must be min. 15 mm. The distance between glass edge ■ Gaskets
and gasket cap (C) has to be min. 3 mm. Please note the glass tolerances!
– T-connectors are to be coordinated with RAICO. Article No. PU
– The length of the pressure profile screws is to be determined graphically. Gasket for pressure
011073 100 m
– T195 = Stainless steel flat (t = 2 mm) own production. profile 5
Gasket for mullion 76 150205 20 m
■ Accessories
Article No. PU
Pan head tapping screw
012092 100 pc(s)
5.5x19
Flat fillister head screw
012156 100 pc(s)
5.5x50
Bullet for screw heads 014060 100 pc(s)
Back filling 60/17 167015 100 pc(s)
Base profile carrier 76 168415 500 pc(s)
– Slipping down of the cover profiles must be prevented. Cover profile 76/25 141505 6m
■ Technical information
– The actual infill thickness should be noted.
THERM+ S-I
Add-ons
– For pressure profile – For pressure profile – For pressure profile
no. 118005, 118010, 118015. no. 013007, 013027. no. 013014, 013008, 013028.
– Accessories: – Accessories: – Accessories:
Bullet for screw heads no. 014060. Bullet for screw heads no. 014060. Bullet for screw heads no. 014060.
■ Technical information
– The actual infill thickness should be noted.
■ Technical information
– The actual infill thickness should be noted.
THERM+ S-I
Add-ons
– For pressure profile – For pressure profile – For pressure profile
no. 118005, 118010, 118015. no. 013007, 013027. no. 013014, 013008, 013028.
– Accessories: – Accessories: – Accessories:
Bullet for screw heads no. 014060. Bullet for screw heads no. 014060. Bullet for screw heads no. 014060.
■ Technical information
– The actual infill thickness should be noted.
■ Technical information
– The actual infill thickness should be noted.
THERM+ S-I
Add-ons
– For flat pressure profile – For flat pressure profile
no. 013300, 013310, 013313. no. 013300, 013310, 013313.
– Accessories: – Accessories:
Bullet for screw heads no. 014060. Bullet for screw heads no. 014060.
■ Technical information
– The actual infill thickness should be noted.
■ Technical information
– The actual infill thickness should be noted.
THERM+ S-I
Add-ons
– For pressure profile – For pressure profile
no. 118005, 118010, 118015. no. 118005, 118010, 118015.
– Accessories: – Accessories:
Protection insert no. 915110. Protection insert no. 915110.
■ Technical information
– The actual infill thickness should be noted.
■ Technical information
– The actual infill thickness should be noted.
THERM+ S-I
Add-ons
– For pressure profile – For pressure profile – For pressure profile
no. 118005, 118010, 118015. no. 013007, 013027. no. 013014, 013008, 013028.
– Accessories: – Accessories: – Accessories:
Bullet for screw heads no. 014060. Bullet for screw heads no. 014060. Bullet for screw heads no. 014060.
Pressure profile reinforcement
no. 013111.
■ Technical information
– The actual infill thickness should be noted.
THERM+ S-I
classes. The maximum size of 1.500 x 3.000 mm of the panes
Add-ons
provides a new dimension in fire protection.
If the facade constructions not only comply with the exact specifi-
cations of the classification report but also with our technical specifi-
cations, and if this is also a curtain wall in accordance with product
standard DIN EN 13830, the fire resistance can be classified acc. to
DIN EN 13501-2:2008-01.
RAICO must be consulted for country-specific verifications.
THERM+ S-I
- 28 to 33 mm: fire protection block 50/21 (no. 168640)
Add-ons
- 34 to 47 mm: fire protection block 50/27 (no. 168642) Cover profile 50/15 013003 6m
- 48 to 60 mm: fire protection block 50/41 (no. 168644). Cover profile 50/12 013004 6m
– The maximum admissible filling sizes depend on Pressure profile 47
118005 6m
the glass product (see overview for admissible filling punched
elements). Base profile 129005 6m
– Fire exposure from the inside and outside permissible.
– Fire protection according to classification report ■ Gaskets
11-003319-PR01 (ift Rosenheim).
Article No. PU
– Technical indications for the execution
have to be observed. Gasket for pressure
011070.LI 100 m
profile 3
– T209 = Depths from 60 to 160 mm.
Gasket for pressure
– T210 = Depths from 80 to 160 mm. 011070.RE 100 m
profile 3
Gasket for mullion 50 D 150007 20 m
Gasket for transom 50 D 150012 20 m
Fire protection block
168640 50 m
50/21
■ Accessories
Article No. PU
Countersunk sheet metal 100
012028
screw 5.5x22 pc(s)
Pan head tapping screw 100
012114
5.5x42 pc(s)
Sheet 40 167050 10 pc(s)
Fire protection tape 18/1 167060 25 m
Glass carrier 27 to 28 167341 10 pc(s)
■ Gaskets
Article No. PU
Gasket for pressure
011073 100 m
profile 5
Gasket for mullion 50 D 150007 20 m
Fire protection block
168640 50 m
50/21
■ Accessories
Article No. PU
Pan head tapping screw 100
012115
5.5x45 pc(s)
Sheet 40 167050 10 pc(s)
THERM+ S-I
must be prevented.
Add-ons
Cover profile 50/15 013003 6m
– For more cover profiles, end caps and
belay sheet see Product range. Cover profile 50/12 013004 6m
Cover profile 50/25 013005 6m
Cover profile 50/25 013201 6m
Cover profile 50/20 013210 6m
Pressure profile 47
118005 6m
punched
Cover profile 50/13.5 141101 6m
Cover profile 50/25 141104 6m
Cover profile 50/30 141106 6m
■ Accessories
Article No. PU
Countersunk sheet metal 100
012028
screw 5.5x22 pc(s)
Pan head tapping screw 100
012114
5.5x42 pc(s)
Sheet 40 167050 10 pc(s)
Fire protection tape 18/1 167060 25 m
Glass carrier 27 to 28 167341 10 pc(s)
150112
THERM+ S-I
with RAICO.
Add-ons
Cover profile 56/15 013023 6m
– The length of the pressure profile screws
is to be determined graphically. Pressure profile 53
118010 6m
punched
Base profile 129005 6m
■ Gaskets
Article No. PU
Gasket for pressure
011073 100 m
profile 5
Gasket for mullion 56 D 150107 20 m
Fire protection block
168646 50 m
56/21
■ Accessories
Article No. PU
Pan head tapping screw 100
012115
5.5x45 pc(s)
Sheet 40 167050 10 pc(s)
■ Technical information
– The actual infill thickness should be noted.
THERM+ S-I
Add-ons
– For pressure profile
no. 118005, 118010.
– Accessories:
Sheet no. 167050.
■ Technical information
– The actual infill thickness should be noted.
■ Technical information
– Max. load transmisson with 1 or 2 glass carriers
THERM+ S-I
per support point: see chapter Assembly options.
Add-ons
– Screw connection with
- 3 countersunk sheet metal screws no. 012028
each for no. 167341.
- 3 flat fillister head screws no. 012100
each for no. 167346 to 167921.
Infill thickness
No. Article PU
mm
28 167341 Al. glass carrier 27 to 28 10 pc(s)
29 to 30 167346 Al. glass carrier 29 to 30 10 pc(s)
31 to 32 167351 Al. glass carrier 31 to 32 10 pc(s)
33 to 34 167356 Al. glass carrier 33 to 34 10 pc(s)
35 to 36 167361 Al. glass carrier 35 to 36 10 pc(s)
37 to 38 167366 Al. glass carrier 37 to 38 10 pc(s)
39 to 40 167371 Al. glass carrier 39 to 40 10 pc(s)
41 to 42 167376 Al. glass carrier 41 to 42 10 pc(s)
43 to 44 167381 Al. glass carrier 43 to 44 10 pc(s)
45 to 46 167386 Al. glass carrier 45 to 46 10 pc(s)
47 to 48 167391 Al. glass carrier 47 to 48 10 pc(s)
49 to 50 167396 Al. glass carrier 49 to 50 10 pc(s)
51 to 52 167401 Al. glass carrier 51 to 52 10 pc(s)
53 to 54 167906 Al. glass carrier 53 to 54 10 pc(s)
55 to 56 167911 Al. glass carrier 55 to 56 10 pc(s)
57 to 58 167916 Al. glass carrier 57 to 58 10 pc(s)
59 to 60 167921 Al. glass carrier 59 to 60 10 pc(s)
Max. permissible
dimensions
Article
Width x Height Width x Height
mm mm
Pilkington Pyrodur® 30-25 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-26 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-27 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-28 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-35 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-36 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-37 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-38 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-35 Triple* 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-36 Triple* 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-37 Triple* 1.300 x 3.000 2.600 x 1.200
Pilkington Pyrodur® 30-38 Triple* 1.300 x 3.000 2.600 x 1.200
174 2017
THERM+ S-I
Fire protection
■ Technical information
– Maximum permissible dimensions:
THERM+ S-I
see overview of permissible filling elements.
Add-ons
– Fire exposure from the inside and outside
permissible.
– Fire protection according to classification
report 11-003319-PR01 (ift Rosenheim).
Alu sheet t ≥ 2 mm or
Steel sheet t ≥ 1 mm
Alu or
Steel sheet t ≥ 2 mm
■ Technical information
– Maximum permissible dimensions:
see overview of permissible filling elements.
– Fire exposure from the inside and outside
permissible.
– Fire protection according to classification
report 11-003319-PR01 (ift Rosenheim).
Alu sheet t ≥ 2 mm or
Steel sheet t ≥ 1 mm
Alu or
Steel sheet t ≥ 2 mm
Technical information
– Structural steel profiles
THERM+ S-I
System width: 50 to 60 mm
Add-ons
Mullion depth: 80 to 160 mm
Transom depth: 60 to 160 mm for field width < 1500 mm
80 to 160 mm for field width from 1500 mm.
– Use steel rectangular tubes with wall thicknesses from 3 to 4.5 mm.
– The T-connections must be of circumferentially welded design.
– When using T-connector no. 016300, the transoms must be
installed with a gap of 1 mm and circumferentially welded.
– The width of the fire protection curtain wall is not limited.
– Use screw channel no. 129005.
– Only interior gaskets type D (with or without flap) are admissible.
– Fire exposure from the inside and outside permissible.
– Use of 1 to 2 aluminium glass carriers per side → max. filling weight:
600 kg (300 kg per pair of glass carriers).
– Setting blocks made of hardwood (except beech) or inorganic material
must be used (recommendation: Promat).
– The intumescent fire protection strip in the rebate must be interrupted
in the glass carrier area. The fire protection strip article no. 167060
must be used in this area.
– It is to be ensured that aeration and vent openings are not covered.
– Use dry transom sealing pieces (e. g. no. 152010).
– Admissible exterior gaskets:
No. 011070 (3 mm), 011077 (4 mm) or 011073 (5 mm).
– Admissible pressure and cover profiles see pages Cover profile
options.
– The height is unlimited; the maximum mullion length is 5000 mm.
– The maximum carrier spacing at height is 5000 mm.
– All cavities at structural connections must be completely insulated with
non-combustible mineral wool with a melting point > 1000 °C and a
gross density ≥ 40 kg/m³ (recommendation: Fixrock or Formrock from
Rockwool).
– Bracket and fasteners in accordance with static requirements.
– Structural connections must be designed in such a way that expansion
in addition to the normal facade movement + 30 mm can be absorbed
in the event of a fire.
In addition, the specifications from the classification report
no. 11-003319-PR01 (ift Rosenheim) dated 05 March 2012 must
be observed.
2017 177
178 2017
THERM+ S-I
Stuctural Glazing SG2
■ Features SG2-system
– Free choice of support construction (rectangular
THERM+ S-I
and square tubes, sectional steel, full material).
Add-ons
– System widths 50 and 56 mm.
– Combination possible with THERM+ basic system.
– Support- and basic construction as well as the interior
gasket system are identical to the THERM+ basic system.
– Variable capabilities.
– Slim elevation widths.
– Homogeneous, building enveloping glass area.
– Maximum possible transparency.
– Many application possibilities.
– Approved curtain wall system.
– Infill thicknesses of 32 up to 64 mm.
– Simple and efficient assembly.
THERM+ S-I
and installation must be respected.
Add-ons
U-profile 034052 3m
– Glass bite 13 mm.
Base profile 129005 6m
Base profile 50/56/76 168400 200 m
■ Gaskets
Article No. PU
Gasket for mullion 50 L 150006 20 m
Gasket for transom 50 L 150011 20 m
Insulating block SG
168550 50 m
25/14
■ Accessories
Article No. PU
Flat fillister head screw 100
012100
5.5x22 pc(s)
Pan head tapping screw 100
012107
5.5x25 pc(s)
Sealing piece 100
152010
for transom 50 pc(s)
Toggle 20/58 SG 164610 10 pc(s)
Glass carrier 29 to 30 167346 10 pc(s)
500
Base profile carrier 50 168405
pc(s)
■ Gaskets
Article No. PU
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Insulating block SG
168550 50 m
25/14
■ Accessories
Article No. PU
Flat fillister head screw 100
012100
5.5x22 pc(s)
Pan head tapping screw 100
012107
5.5x25 pc(s)
Sealing piece 100
152015
for transom 56 pc(s)
Toggle 20/58 SG 164610 10 pc(s)
Glass carrier 29 to 30 167346 10 pc(s)
500
Base profile carrier 56 168410
pc(s)
■ Technical information
– Approval required in individual cases.
THERM+ S-I
Add-ons
– T129 = Vapour-tight membrane no. 951019.
■ Technical information
– T30 = Notching.
– T31 = Width of glass joint 24 mm.
– T142 = Screwing in of the SG toggle
with tool no. 170750.
THERM+ S-I
RH = Grid height.
Add-ons
– T58 = Length of the gasket for transom
= RB - 28 + 0.5% add-on.
– T66 = Length of the base profile = RB - 56.
– T67 = Glass dimension = RB or RH - 24.
T58
T66
T65
T115
■ Technical information
– Screw selection tables apply only for a cavity
THERM+ S-I
of 18 mm between the glass panes (glass edge)
Add-ons
and a centric position of the aluminium U profile
no. 034052 in the glass edge.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw
lengths have to be selected based on the planning
manuals for THERM+ H-I or THERM+ A-I.
– T262 = Nominal dimension
(= inner pane thickness + 5 mm).
Nominal
Length
dimension No.
mm
mm
11 to 13 012107 25
14 to 16 012108 28
17 to 18 012109 30
19 to 20 012110 32
21 to 23 012111 35
24 to 26 012112 38
27 to 28 012113 40
29 to 30 012114 42
31 to 33 012115 45
34 to 36 012116 48
37 to 38 012117 50
39 to 40 012118 52
41 to 43 012119 55
■ Technical information
– When using the aluminium base profile, the screw
lengths have to be selected based on the planning
manuals for THERM+ H-I or THERM+ A-I.
– For suction disc no. 163807, – For suction disc no. 163807,
163810, 163812. 163810, 163812.
Stainless Stainless
Infill thickness RAL 9004 Length Infill thickness RAL 9004 Length
steel steel
mm No. mm mm No. mm
No. No.
20 to 22 907202 907252 36 10 to 12 907202 907252 36
23 to 25 907204 907254 39 13 to 15 907204 907254 39
26 to 27 907206 907256 41 16 to 17 907206 907256 41
28 to 29 907208 907258 43 18 to 19 907208 907258 43
30 to 31 907210 907260 45 20 907210 907260 45
32 to 33 907212 907262 47
34 to 35 907214 907264 49
36 to 37 907216 907266 51
38 to 39 907218 907268 53
40 to 41 907220 907270 55
42 to 43 907222 907272 57
44 to 45 907224 907274 59
46 to 47 907226 907276 61
48 to 49 907228 907278 63
50 to 51 907230 907280 65
52 to 53 907232 907282 67
54 to 55 907234 907284 69
56 to 57 907236 907286 71
58 to 59 907238 907288 73
60 to 61 907240 907290 75
62 to 64 907242 907292 78
■ Technical information
– When using the aluminium base profile, the screw
THERM+ S-I
lengths have to be selected based on the planning
Add-ons
manuals for THERM+ H-I or THERM+ A-I.
– For suction disc no. 163809, – For suction disc no. 163809,
163811, 163813. 163811, 163813.
Stainless Stainless
Infill thickness RAL 9004 Length Infill thickness RAL 9004 Length
steel steel
mm No. mm mm No. mm
No. No.
20 012350 012174 35 20 012310 012011 35
21 to 22 012351 012175 38 21 to 22 012311 012012 38
23 to 24 012352 012176 40 23 to 24 012312 012139 40
25 to 27 012353 012177 42 25 to 27 012313 012013 42
28 to 30 012354 012178 45 28 to 30 012314 012014 45
31 to 32 012355 012179 48 31 to 32 012315 012140 48
33 to 34 012356 012180 50 33 to 34 012316 012015 50
35 to 37 012357 012181 52 35 to 37 012317 012141 52
38 to 40 012358 012182 55 38 to 40 012318 012016 55
41 to 42 012359 012183 58 41 to 42 012319 012142 58
43 to 44 012360 012184 60 43 to 44 012320 012017 60
45 to 47 012361 012185 62 45 to 47 012321 012143 62
48 to 50 012362 012186 65 48 to 50 012322 012018 65
51 to 52 012363 012190 68 51 to 52 012323 012020 68
53 to 54 012364 012187 70 53 to 54 012324 012146 70
55 to 57 012365 012192 72 55 to 57 012325 012147 72
58 to 60 012366 012188 75 58 to 60 012326 012148 75
61 to 62 012367 012194 78 61 to 62 012327 012260 78
63 to 64 012368 012189 80 63 to 64 012328 012149 80
■ Technical information
– When using the aluminium base profile, the screw
lengths have to be selected based on the planning
manuals for THERM+ H-I or THERM+ A-I.
– For suction disc no. 163807, – For suction disc no. 163807,
163810, 163812. 163810, 163812.
Stainless Stainless
Infill thickness RAL 9004 Length Infill thickness RAL 9004 Length
steel steel
mm No. mm mm No. mm
No. No.
10 012350 012174 35 10 012310 012011 35
11 to 12 012351 012175 38 11 to 12 012311 012012 38
13 to 14 012352 012176 40 13 to 14 012312 012139 40
15 to 17 012353 012177 42 15 to 17 012313 012013 42
18 to 20 012354 012178 45 18 to 20 012314 012014 45
21 to 22 012355 012179 48 21 to 22 012315 012140 48
23 to 24 012356 012180 50 23 to 24 012316 012015 50
25 to 27 012357 012181 52 25 to 27 012317 012141 52
28 to 30 012358 012182 55 28 to 30 012318 012016 55
31 to 32 012359 012183 58 31 to 32 012319 012142 58
33 to 34 012360 012184 60 33 to 34 012320 012017 60
35 to 37 012361 012185 62 35 to 37 012321 012143 62
38 to 40 012362 012186 65 38 to 40 012322 012018 65
41 to 42 012363 012190 68 41 to 42 012323 012020 68
43 to 44 012364 012187 70 43 to 44 012324 012146 70
45 to 47 012365 012192 72 45 to 47 012325 012147 72
48 to 50 012366 012188 75 48 to 50 012326 012148 75
51 to 52 012367 012194 78 51 to 52 012327 012260 78
■ Technical information
– The outer pane must be in tempered glass
THERM+ S-I
with min. 8 mm thickness.
Add-ons
– A silicone joint width of 8 to 9 mm results by using
this table, exept for an infill thickness of 25 mm.
In that case the silicone joint width is 10 mm.
– From an infill thickness of 32 mm with aluminium
U profile no. 034052 possible.
– When using the aluminium base profile, the screw lengths
have to be selected based on the planning manuals for
THERM+ H-I or THERM+ A-I.
Infill thickness
No.
mm
23 to 25 168541
26 to 27 168544
28 to 29 168546
30 to 31 168548
32 to 33 168550
34 to 35 168552
36 to 37 168554
38 to 39 168556
40 to 41 168558
42 to 43 168560
44 to 45 168562
46 to 47 168564
48 to 49 168566
50 to 51 168568
52 to 53 168570
54 to 55 168572
56 to 57 168564 + 168546
58 to 59 2x 168556
60 to 61 168568 + 168546
62 to 63 2x 168558
64 168572 + 168546
■ Technical information
– The outer pane must be in tempered glass with min. 8 mm thickness.
– Bearing surface of the outer pane on the glass carrier:
min. 50 % of the glass thickness + 1 mm.
– From an infill thickness of 32 mm with aluminium
U profile no. 034052 possible.
– Screw connection with
- 3 countersunk sheet metal screws no. 012028
each for no. 167316 to 167341.
- 3 flat fillister head screws no. 012100
each for no. 167346 to 167926.
– When using the aluminium base profile, the screw lengths have to be selected
based on the planning manuals for THERM+ H-I or THERM+ A-I.
Infill thickness
No. Article PU
mm
20 to 21 167316 Glass carrier 17 to 18 10 pc(s)
22 to 23 167321 Glass carrier 19 to 20 10 pc(s)
24 to 25 167326 Glass carrier 21 to 22 10 pc(s)
26 to 27 167331 Glass carrier 23 to 24 10 pc(s)
28 to 29 167336 Glass carrier 25 to 26 10 pc(s)
30 to 31 167341 Glass carrier 27 to 28 10 pc(s)
32 to 33 167346 Glass carrier 29 to 30 10 pc(s)
34 to 35 167351 Glass carrier 31 to 32 10 pc(s)
36 to 37 167356 Glass carrier 33 to 34 10 pc(s)
38 to 39 167361 Glass carrier 35 to 36 10 pc(s)
40 to 41 167366 Glass carrier 37 to 38 10 pc(s)
42 to 43 167371 Glass carrier 39 to 40 10 pc(s)
44 to 45 167376 Glass carrier 41 to 42 10 pc(s)
46 to 47 167381 Glass carrier 43 to 44 10 pc(s)
48 to 49 167386 Glass carrier 45 to 46 10 pc(s)
50 to 51 167391 Glass carrier 47 to 48 10 pc(s)
52 to 53 167396 Glass carrier 49 to 50 10 pc(s)
54 to 55 167401 Glass carrier 51 to 52 10 pc(s)
56 to 57 167906 Glass carrier 53 to 54 10 pc(s)
58 to 59 167911 Glass carrier 55 to 56 10 pc(s)
60 to 61 167916 Glass carrier 57 to 58 10 pc(s)
62 to 63 167921 Glass carrier 59 to 60 10 pc(s)
64 167926 Glass carrier 61 to 62 10 pc(s)
■ Technical information
– For additional mechanical saving
THERM+ S-I
for all heights larger than 8 m.
Add-ons
Suction disc set 75 Suction disc set 50/90 Suction disc set 56/90
No. 163807 No. 163810 No. 163812
No. 163809 No. 163811 No. 163813
■ Technical information
– T164 = Built-in conditions.
– T170 = Assembly suction disc.
– T171 = Suction disc variants.
– T172 = Suction disc set.
– T201 = Assembly aid no. 015230.
SG-curtain walls with silicone joint SG-curtain walls with silicone joint on two
on four sides sides and pressure profile on two sides
THERM+ S-I
Add-ons
■ Technical information ■ Technical information
– In the curtain wall THERM+ SG2 the glass units are fixed – In case of silicone joints on two sides of a glass unit, this
by means of aluminium toggles SG no. 164610. must be fixed additionally with suction discs (see Product
The quantity of the toggles and the structural values of the range) with at least one screw (diameter 5.5) in
bonding must be determined by an approved specialist, distances of max. 500 mm. The bearing surface of the
taking into consideration the maximum distance of suction discs must be min. 1.000 mm2 per glass unit. The
500 mm between two toggles. aluminium disc must be underlaid with a weatherproof
– The national building regulations and codes must be silicone disc (60 to 70 shore). As an alternative the glass
applied. A permit may be required for the particular unit can be fixed with special toggles in the glass edge,
project. If an additional mechanical fuxture is required, see system THERM+ SG2.
RAICO suction discs can be applied (see Product range) – The backing for the exerior silicone joint must be executed
– For assembly and installation the RAICO assembly with the insulation block SG (height according to the infill
instructions must be followed. For the silicone joint the thickness). The silicone joint must be at least 8 mm. The
indications of the manufacturer of the sealant must be material must be suitable for weatherproof sealing
respected in terms of adhesion on the glass edge and between glass units. Possible chemical interactions with
chemical interaction with the glass edge sealant. the sealant of the glass edge and, in case of laminated
Insulated glass units must feature a UV-resistant glass glass, with the interlayer must be coordinated with the
edge sealant. The necessary glass quality and thickness suppliers. The instructions of the manufacturers of these
must be coordinated with the glass supplier. materials must be applied.
If exterior silicone joints get in contact with pressure
– The silicone joint must be at least 8 mm. The exterior
profiles, a RAICO silicone pressure profile gasket (see
glass pane must be made of tempered glass with heat
product range), must be used. Penetrations in the silicone
soak test with a minimum thickness of 8 mm. The cavity
joint must be sealed with the same material. If screws
between the glass panes (glass edge) must be min.
without washer are used for the suctions discs, the screw
18 mm, the interior glass pane min. 6 mm.
heads must be sealed with the material of the silicone
– Glass tolerances: joints.
– The total tolerances of the glass units must be limited to – Introduction:
+/- 2 mm. The panes must be produced on the standing
– Seam the exterior glass verge.
edge.
2017 195
196 2017
Content
Assembly options
Connector technology
Transom connection for steel tubes 199
Transom connection for t-shaped steel profiles 201
Assembly steel connector SC/SCL 204
Glazing/Sealing technology
Minimum bearing surface 206
Assembly options
Load transmission 207
THERM+ S-I
Overview and selection of glass carriers 221
Interior sealing system 222
Exterior sealing system 235
Screw selection 246
Accessories
Fixation for sun protection systems 257
Installation scaffolding fixation 284
Installation fixture unit 285
Curtain wall mounting 286
Connection profiles 290
Suction discs 308
Belay sheet 309
Statical values 310
2017 197
198 2017
THERM+ S-I
Connector technology
■ Technical information
– The steel construction must be flush on
the glazing side. Max. misalignment between
mullion and transom = ± 0.5 mm.
– Welded joint and wall thickness of the transom
profile has to be calculated under consideration
of static and loads.
– Please consider a minimum bearing surface
for gaskets.
Assembly options
THERM+ S-I
Wall
Max. Max.
thick-
glass infill
ness
weight thickness
transom
kg mm
mm
2.9 100 30
3.0 105 30
3.2 120 30
3.6 145 30
4.0 165 32
4.5 200 34
Maximum load per T-connection
= max. glass weight : 2
■ Technical information
– The steel construction must be flush on
the glazing side. Max. misalignment between
mullion and transom = ± 0.5 mm.
– Welded joint and wall thickness of the transom
profile has to be calculated under consideration
of static and loads.
– Please consider a minimum bearing surface
for gaskets.
Assembly options
THERM+ S-I
■ Technical information
– For subsequent transom assembly.
– The steel construction must be flush on the
glazing side. Max. misalignment between
mullion and transom = ± 0.5 mm.
– Welded joint and wall thickness of the transom
profile has to be calculated under consideration
of static and loads.
– Proposal for constructing a transom connection
on site.
– Please consider a minimum bearing surface
for gaskets.
■ Technical information
– For subsequent transom assembly.
– The steel construction must be flush on the
glazing side. Max. misalignment between
mullion and transom = ± 0.5 mm.
– Welded joint and wall thickness of the transom
profile has to be calculated under consideration
of static and loads.
– Proposal for constructing a transom connection
Assembly options
on site.
THERM+ S-I
– Please consider a minimum bearing surface for
gaskets.
■ Technical information
– Further information see Processing.
– T82 = Mullion element.
– T86 = Transom element.
– T265 = Special flat fillister head screw
M6.0x15 no. 908953.
– T266 = Special threaded pin.
– T267 = Special flat fillister head screw
5.0x30 no. 908030.
– T268 = Fixing element 61.
– T269 = Reinforcing plate.
– T306 = Interior dimension transom depth.
– T307 = Interior dimension transom width.
Int. dimens.
Fixing
transom
element
depth
No.
mm
39 to 61 430155
> 61 to 83 430160
> 83 to 105 430165
■ Technical information
– Fixing elements for more interior
dimensions of the transom on demand.
– T265 = Special flat fillister head screw
M6x15 no. 908953.
– T270 = Steel connector SCL.
– T271 = Special flat fillister head screw
M6x46 no. 908954.
– T272 = Fixing part.
Assembly options
THERM+ S-I
– T273 = Special flat fillister head screw
5.0x15 no. 908046.
– T307 = Interior dimension transom width.
Screw connection
Interior
Steel connector SCL Fixing part Steel Mullion
dimension
transom connector Fixing part part with
width SCL transom
mm No. No. No.
No. Article No. Article
908954 908953 908046
42 430050 Steel connector SCL 8 430210 Fixing part 50/4
44 430213 Fixing part 50/3
46 430219 Fixing part 50/2
50 430225 Fixing part 60/5 3x 2x 2x
430052 Steel connector SCL 3
52 430228 Fixing part 60/4
54 430231 Fixing part 60/3
56 430240 Fixing part 60/2
■ Technical information
– For glass loads up to 400 kg the load trans-
mission needs one glass carrier per side.
- Synthetic glass carrier:
Infill thicknesses from 10 up to 64 mm:
Fixation with 3 countersunk screws
no. 012049 each.
- Aluminium glass carrier:
Infill thickness up to 28 mm fixed by
Assembly options
3 countersunk screws no. 012028 each.
Infill thickness from 29 mm fixed by
THERM+ S-I
3 flat fillister head screws no. 012100 each.
– Four additional welding seams in the area
of glass carriers (see Processing).
– Max. load per glass carrier: 200 kg.
– Selection of the glass carriers and the suitable
screws see Overview and selection glass
carriers.
■ Technical information
– For glass loads up to 600 kg the load trans-
mission needs two glass carriers per side.
- Synthetic glass carrier:
Infill thicknesses from 10 up to 64 mm:
Fixation with 3 countersunk screws
no. 012049 each.
- Aluminium glass carrier:
Infill thickness up to 28 mm fixed by
3 countersunk screws no. 012028 each.
Infill thickness from 29 mm fixed by
3 flat fillister head screws no. 012100 each.
– Seven additional welding seams in the area
of glass carriers (see Processing).
– Max. load per set of glass carriers: 300 kg.
– Selection of the glass carriers and the suitable
screws see Overview and selection glass
carriers.
Assembly options
– Max. load per glass carrier: 400 kg. 35 to 36 163660 Glass carrier set 35 to 36 1 set
THERM+ S-I
37 to 38 163665 Glass carrier set 37 to 38 1 set
39 to 40 163670 Glass carrier set 39 to 40 1 set
41 to 42 163675 Glass carrier set 41 to 42 1 set
43 to 44 163680 Glass carrier set 43 to 44 1 set
45 to 46 163685 Glass carrier set 45 to 46 1 set
47 to 48 163690 Glass carrier set 47 to 48 1 set
49 to 50 163695 Glass carrier set 49 to 50 1 set
51 to 52 163700 Glass carrier set 51 to 52 1 set
53 to 54 163705 Glass carrier set 53 to 54 1 set
55 to 56 163710 Glass carrier set 55 to 56 1 set
57 to 58 163715 Glass carrier set 57 to 58 1 set
59 to 60 163720 Glass carrier set 59 to 60 1 set
61 to 62 163725 Glass carrier set 61 to 62 1 set
63 to 64 163730 Glass carrier set 63 to 64 1 set
* unsuitable for use with flat pressure profile
■ Technical information
– For glass loads up to 1500 kg the load trans-
mission needs a steel plate (t = 12 mm) (to be
provided on site) per side.
– Dimensions of the steel plate, the wall
thickness of the structural profiles as well
as the welded joint has to be calculated
under statistical consideration.
– The notching of the interior gasket must
be sealed with sealing material no. 952015
(EPDM-gaskets) or special silicone no. 952020
(silicone-gaskets).
– Use tool no. 170390 for cutting the interior
gasket for all continuous parts.
■ Technical information
– For glass loads up to 200 kg the load trans-
mission needs one glass carrier each side.
– Four additional welding seams in the area
of glass carriers (see Processing).
– Max. load per set of glass carriers: 100 kg.
– Selection of the glass carriers and the suitable
screws see Overview and selection glass
carriers.
Assembly options
THERM+ S-I
■ Technical information
– Glass loads see THERM+ FS-I, category assembly options, chapter glass weights.
– Selection of the glass carriers and the suitable screws see Overview and selection glass carriers.
– For Integration elements the
- Base profile glass carrier L IE no. 167700 (50) or 167702 (56) are required.
- Base profile glass carrier L and base profile adapter (see table) do not apply in this case.
– T155 = Transom gasket.
– T242 = Glass carrier.
– T285 = Tapping screw.
– T286 = Base profile adapter.
– T289 = Base profile glass carrier.
– T290 = Special flat fillister head screw.
– T292 = Special flat fillister head screw no. 908952.
– T308 = Base profile.
– T309 = Standard steel profile.
Assembly options
THERM+ S-I
THERM+ 56 S-I with steel connector SCL
Glass carrier
Construction unit Fixing material
option
No. Article Qty No. Article
L 160711 Base profile adapter 56 2 908952 Special flat fillister head screw M5 x 10
(1 glass carrier 167837/ Base profile
per side) 5 908952 Special flat fillister head screw M5 x 10
167838 glass carrier 56 L
■ Technical information
– Glass loads see THERM+ FS-I, category assembly options, chapter glass weights.
– Selection of the glass carriers and the suitable screws see Overview and selection glass carriers.
– For Integration elements the
- Base profile glass carrier L IE no. 167700 (50) or 167702 (56) are required.
- Base profile glass carrier L and base profile adapter (see table) do not apply in this case.
– T155 = Transom gasket.
– T242 = Glass carrier.
– T285 = Tapping screw.
– T286 = Base profile adapter.
– T289 = Base profile glass carrier.
– T292 = Special flat fillister head screw no. 908952.
– T308 = Base profile.
– T309 = Standard steel profile.
■ Technical information
– Glass loads see THERM+ FS-I, category assembly options, chapter glass weights.
– Selection of the glass carriers and the suitable screws
see Overview and selection glass carriers.
– Applicable from a transom depth of 90 mm and a wall thickness of 3 mm in the transom.
– T155 = Transom gasket.
– T242 = Glass carrier.
– T285 = Tapping screw.
– T289 = Base profile glass carrier.
– T290 = Special flat fillister head screw.
– T292 = Special flat fillister head screw no. 908952.
– T308 = Base profile.
– T309 = Standard steel profile.
Assembly options
THERM+ S-I
THERM+ 56 S-I with steel connector SC
Glass carrier
Construction unit Fixing material
option
No. Article Qty No. Article
■ Technical information
– Glass loads see THERM+ FS-I, category assembly options, chapter glass weights.
– Selection of the cross glass carriers and the suitable screws
see Assembly and installation of cross glass carriers.
– Applicable from a transom depth of 90 mm.
– T154 = Mullion gasket.
– T155 = Transom gasket.
– T289 = Base profile glass carrier.
– T292 = Special flat fillister head screw no. 908952.
– T294 = Special flat fillister head screw no. 908038.
– T295 = Flat fillister head screw no. 012101.
– T297 = Cross glass carrier set.
– T298 = Base profile mullion.
– T308 = Base profile.
– T309 = Standard steel profile.
– T310 = Flat fillister head screw.
■ Technical information
– Glass loads see THERM+ FS-I, category assembly options, chapter glass weights.
– Selection of the cross glass carriers and the suitable screws
see Assembly and installation of cross glass carriers.
– Applicable from a transom depth of 90 mm.
– T154 = Mullion gasket.
– T155 = Transom gasket.
– T289 = Base profile glass carrier.
– T292 = Special flat fillister head screw no. 908952.
– T295 = Flat fillister head screw no. 012101.
– T297 = Cross glass carrier set.
– T298 = Base profile mullion.
– T308 = Base profile.
– T309 = Standard steel profile.
– T310 = Flat fillister head screw.
Assembly options
must be taken by the structural construction. 45 to 46 163760 Cross point glass carrier set 45 to 46 2 pc(s)
THERM+ S-I
– T144 = Glass shim. 47 to 48 163762 Cross point glass carrier set 47 to 48 2 pc(s)
49 to 50 163764 Cross point glass carrier set 49 to 50 2 pc(s)
– T145 = Cross point glass carriers set
51 to 52 163766 Cross point glass carrier set 51 to 52 2 pc(s)
(selection see table).
53 to 54 163768 Cross point glass carrier set 53 to 54 2 pc(s)
– T149 = External view.
55 to 56 163770 Cross point glass carrier set 55 to 56 2 pc(s)
57 to 58 163772 Cross point glass carrier set 57 to 58 2 pc(s)
59 to 60 163774 Cross point glass carrier set 59 to 60 2 pc(s)
61 to 62 163776 Cross point glass carrier set 61 to 62 2 pc(s)
63 to 64 163778 Cross point glass carrier set 63 to 64 2 pc(s)
T145
■ Technical information
– T82 = Mullion element.
– T86 = Transom element.
Selection of screws
Alternative: individual order (number of screws per cross point glass carrier)
Screw set Connection Screw connection in transom
no. Screw connection
mullion with transom
or in mullion Double-sided Unilateral
piece
No. No. No. No.
163790
2x 012101 3x 012153 6x 012101 3x 012101
Content per set: screws for 2 cross point glass carriers (1 set per transom needed).
Assembly cross point glass carrier set Assembly cross point glass carrier set
– Assembly double-sided (e. g. in cross point). – Unilateral assembly (e. g. in the edge region).
– Screws have to be ordered separately (see table). The transom piece has to be shortened accordingly.
– Screws have to be ordered separately (see table).
Assembly options
per side)
167835/ Base profile
5 908952 Special flat fillister head screw M5 x 10
THERM+ S-I
167836 glass carrier 50 L
■ Technical information
– Glass loads see THERM+ FS-I, category assembly options, chapter glass weights.
– Selection of the glass carriers and the suitable screws
see Overview and selection glass carriers.
– T155 = Transom gasket.
– T242 = Glass carrier.
– T286 = Base profile adapter.
– T289 = Base profile glass carrier.
– T290 = Special flat fillister head screw.
– T292 = Special flat fillister head screw no. 908952.
– T299 = Special flat fillister head screw no. 908308.
– T308 = Base profile.
– T309 = Standard steel profile.
■ Technical information
– Glass loads see THERM+ FS-I, category assembly options, chapter glass weights.
– Selection of the glass carriers and the suitable screws
see Overview and selection glass carriers.
– T155 = Transom gasket.
– T242 = Glass carrier.
– T286 = Base profile adapter.
– T289 = Base profile glass carrier.
– T292 = Special flat fillister head screw no. 908952.
– T308 = Base profile.
– T309 = Standard steel profile.
Assembly options
25 to 26 162035 167336 Glass carrier 25 to 26 10 pc(s)
THERM+ S-I
27 to 28 162040 167341 Glass carrier 27 to 28 10 pc(s)
29 to 30 162045 167346 Glass carrier 29 to 30 10 pc(s)
31 to 32 162050 167351 Glass carrier 31 to 32 10 pc(s)
33 to 34 162055 167356 Glass carrier 33 to 34 10 pc(s)
35 to 36 162060 167361 Glass carrier 35 to 36 10 pc(s)
37 to 38 162065 167366 Glass carrier 37 to 38 10 pc(s)
39 to 40 162070 167371 Glass carrier 39 to 40 10 pc(s)
41 to 42 162075 167376 Glass carrier 41 to 42 10 pc(s)
43 to 44 162080 167381 Glass carrier 43 to 44 10 pc(s)
45 to 46 162085 167386 Glass carrier 45 to 46 10 pc(s)
47 to 48 162090 167391 Glass carrier 47 to 48 10 pc(s)
49 to 50 162095 167396 Glass carrier 49 to 50 10 pc(s)
51 to 52 162100 167401 Glass carrier 51 to 52 10 pc(s)
53 to 54 162105 167906 Glass carrier 53 to 54 10 pc(s)
55 to 56 162110 167911 Glass carrier 55 to 56 10 pc(s)
57 to 58 162115 167916 Glass carrier 57 to 58 10 pc(s)
59 to 60 162120 167921 Glass carrier 59 to 60 10 pc(s)
61 to 62 162125 167926 Glass carrier 61 to 62 10 pc(s)
63 to 64 162130 167931 Glass carrier 63 to 64 10 pc(s)
■ Technical information
– Glass loads see THERM+ FS-I, category assembly options,
chapter glass weights.
– Requirement of screws per glass carrier:
- Synthetic glass carrier:
Infill thicknesses from 12 to 64 mm fixed by 3x screw no. 012049 each.
- Aluminium glass carrier:
Infill thickness up to 28 mm fixed by 3x screw no. 012028 each.
Infill thickness from 29 mm fixed by 3x screw no. 012100 each.
■ Technical information
– Glass loads see THERM+ FS-I, category assembly options,
chapter glass weights.
– Requirement of screws per glass carrier:
- Aluminium glass carrier fixed by 3x screw no. 908308 each.
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Optional for gaskets type “S” the application of the gaskets
type “L” or type “D” is possible.
– Applicable gaskets
- Gasket for mullion with notching by special tool
(see Processing)
No. 150005 Gasket for mullion 50
No. 150105 Gasket for mullion 56
No. 150205 Gasket for mullion 76
No. 150705 Gasket for mullion 96
No. 150040 to 150050 Gasket for mullion 50 polygon
No. 150140 to 150150 Gasket for mullion 56 polygon
- PU = 20 m.
– - Gasket for transom with notching by special tool
(see Processing)
No. 150010 Gasket for transom 50
No. 150110 Gasket for transom 56
No. 150210 Gasket for transom 76
No. 150710 Gasket for transom 96
- PU = 20 m.
Sealing piece for transom gasket
No. 152010 Transom sealing piece 50
No. 152015 Transom sealing piece 56
No. 152020 Transom sealing piece 76
- PU = 100 pc(s)
- Assembly without sealing material.
Transom sealing piece 96 P
No. 152086 Transom sealing piece 96 P
- PU = 100 pc(s)
- Assembly with sealing material D2,
no. 952015 or with special silicone B1,
no. 952020.
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Tightening torque for no. 167007: appr. 2.0 Nm.
– Optional for gaskets type “S” the application of the gaskets
type “L” or type “D” is possible.
– Applicable gaskets
Assembly options
- Gasket for mullion with notching by special tool
(see Processing)
THERM+ S-I
No. 150005 Gasket for mullion 50
No. 150105 Gasket for mullion 56
No. 150205 Gasket for mullion 76
No. 150040 to 150050 Gasket for mullion 50 polygon
No. 150140 to 150150 Gasket for mullion 56 polygon
- PU = 20 m.
- Gasket for transom with notching by special tool
(see Processing)
No. 150015 Gasket for transom 50, flap
No. 150115 Gasket for transom 56, flap
No. 150215 Gasket for transom 76, flap
- PU = 20 m.
Sealing piece for transom gasket
No. 152010 Transom sealing piece 50
No. 152015 Transom sealing piece 56
No. 152020 Transom sealing piece 76
- PU = 100 pc(s)
- Assembly without sealing material.
– T196 = Belay sheet no. 167007.
– T198 = Screw no. 908118.
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Tightening torque for no. 167007: appr. 2.0 Nm.
– Optional for gaskets type “S” the application of the gaskets
type “L” or type “D” is possible.
– Applicable gaskets
- Base gasket with notching by special tool
(see Processing)
No. 150020 Base gasket 50, flap
No. 150120 Base gasket 56, flap
No. 150220 Base gasket 76, flap
- PU = 20 m.
Sealing piece for base gasket
No. 152070 Base transom sealing piece,
applicable for all system widths.
No. 152072 Base transom sealing piece,
applicable for gasket type „D“ for
all system widths.
- PU = 10 pc(s)
- Assembly with sealing material D2, no. 952015
or with special silicone B1, no. 952020.
– T196 = Sealing piece no. 167007.
– T198 = Screw no. 908118.
– T199 = Sealing piece.
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Optional for gaskets type “S” the application of the gaskets
type “L” or type “D” is possible.
– Applicable gaskets (PU = 20 m)
- Base gasket with notching by special tool
(see Processing)
Assembly options
No. 150020 Base gasket 50, flap
THERM+ S-I
No. 150120 Base gasket 56, flap
No. 150220 Base gasket 76, flap
- PU = 20 m.
- Assembly with sealing material D2, no. 952015
or with special silicone B1, no. 952020.
Article No. PU
Interior gasket 50 E3 150008 20 m
Interior gasket 56 E3 150108 20 m
Interior gasket 76 E3 150208 20 m
Article No. PU
Transom sealing piece 50 152010 100 pc(s)
Transom sealing piece 56 152015 100 pc(s)
Transom sealing piece 76 152020 100 pc(s)
Article No. PU
Transom sealing piece 50 E2 152009 100 pc(s)
Transom sealing piece 56 E2 152014 100 pc(s)
Transom sealing piece 76 E2 152019 100 pc(s)
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Optional for gaskets type “S” the application of the gaskets
type “L” or type “D” is possible.
– Applicable gaskets
- Gasket for transom with notching by special tool
(see Processing)
Assembly options
No. 150010 Gasket for transom 50
THERM+ S-I
No. 150110 Gasket for transom 56
No. 150210 Gasket for transom 76
- PU = 20 m.
– - Gasket for transom with notching by special tool
(see Processing)
No. 150013 Interior gasket 50 E2
No. 150113 Interior gasket 56 E2
No. 150213 Interior gasket 76 E2
- PU = 20 m.
Sealing piece for transom gasket
No. 152010 Transom sealing piece 50
No. 152015 Transom sealing piece 56
No. 152020 Transom sealing piece 76
- PU = 100 pc(s)
- Assembly without sealing material.
– T38 = Level 2.
– T40 = Level 1.
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Optional for gaskets type “S” the application of the gaskets
type “L” or type “D” is possible.
– Applicable gaskets
- Gasket for transom with notching by special tool
(see Processing)
No. 150008 Interior gasket 50 E3
No. 150108 Interior gasket 56 E3
No. 150208 Interior gasket 76 E3
- PU = 20 m.
– - Gasket for transom with notching by special tool
(see Processing)
No. 150013 Interior gasket 50 E2
No. 150113 Interior gasket 56 E2
No. 150213 Interior gasket 76 E2
- PU = 20 m.
Sealing piece for transom gasket
No. 152009 Transom sealing piece 50 E2
No. 152014 Transom sealing piece 56 E2
No. 152019 Transom sealing piece 76 E2
- PU = 100 pc(s)
- Assembly without sealing material.
– T38 = Level 2.
– T39 = Level 3.
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Tightening torque for no. 167007: appr. 2.0 Nm.
– Optional for gaskets type “S” the application of the gaskets
type “L” or type “D” is possible.
– Applicable gaskets
– - Gasket for mullion with notching by special tool
Assembly options
(see Processing)
THERM+ S-I
No. 150008 Interior gasket 50 E3
No. 150108 Interior gasket 56 E3
- PU = 20 m.
- Gasket for transom with notching by special tool
(see Processing)
No. 150018 Interior gasket 50 E2 flap
No. 150118 Interior gasket 56 E2 flap
- PU = 20 m.
Sealing piece for transom gasket
No. 152009 Transom sealing piece 50 E2
No. 152014 Transom sealing piece 56 E2
- PU = 100 pc(s)
- Assembly without sealing material.
– T38 = Level 2.
– T39 = Level 3.
– T197 = Sealing piece no. 167007.
– T198 = Screw no. 908118.
■ Technical information
The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Applicable gaskets
- Gasket for transom with notching by special tool
(see Processing).
No. 150461 Transom gasket 50/26
No. 150462 Interior gasket 50/26 E3
- PU = 20 m.
Sealing piece for transom gasket
No. 152007 Transom sealing piece 50/26 E1
- PU = 100 pc(s).
- Assembly without sealing material.
– T188 = Transom sealing piece.
■ Technical information
The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Applicable gaskets
- Gasket for transom with notching by special tool
(see Processing).
No. 150461 Transom gasket 50/26
No. 150463 Interior gasket 50/26 E2
- PU = 20 m.
Assembly options
Sealing piece for transom gasket
THERM+ S-I
No. 152007 Transom sealing piece 50/26 E1
- PU = 100 pc(s)
- Assembly without sealing material.
– T38 = Level 2.
– T40 = Level 1.
■ Technical information
The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Applicable gaskets
- Gasket for transom with notching by special tool
(see Processing).
No. 150462 Interior gasket 50/26 E3
No. 150463 Interior gasket 50/26 E2
- PU = 20 m.
Sealing piece for transom gasket
No. 152011 Transom sealing piece 50/26 E2
- PU = 100 pc(s)
- Assembly without sealing material.
– T38 = Level 2.
– T39 = Level 3.
■ Technical information
A
– The joint areas must be sealed carefully with sealing material
D2 no. 952015 (for silicone gaskets with special silicone B1
no. 952020) after thorough cleansing with cleaner 450
no. 952000. The stainless steel sealing pieces must be fixed
with two screws no. 908118 each.
– For more information see Processing.
– T199 = Sealing piece.
A Straight extension
Assembly options
System Stainless steel sealing piece
THERM+ S-I
width for mullion for transom for level E3
mm PU
no. no. no.
B
50 167105 167131 167103 10 pc(s)
56 167115 – – 10 pc(s)
76 167125 – – 10 pc(s)
50 167130 10 pc(s)
56 167132 10 pc(s)
76 167134 10 pc(s)
43 to 44 8 12 8 10
45 to 46 6 10 6 8
47 to 48 4 8 4 6
49 to 50 2 6 2 4
51 to 52 0 4 0 2
Assembly options
EPDM sealing pieces for pressure profiles
THERM+ S-I
self-adhesive, assembly at the interior side
of the pressure profile
Assembly options
EPDM sealing pieces for pressure profiles
THERM+ S-I
self-adhesive, assembly at the interior side
of the pressure profile
T41
■ Technical information
– All insulating blocks must be notched with
a special tool at the end of the transom gasket
(A) for assembling the sealing piece for
pressure profile (see Processing).
– The version with insulating blocks 21 and
P must be notched (B) additionally with a
special tool in the area of the glass support
(see Processing).
– PU of the insulating blocks = 50 m.
– T50 = Notching A.
– T51 = Notching B.
– T162 = Cross point sealing plate.
– T163 = Sealing piece for pressure profile.
■ Technical information Selection of interior joint plate and profile joint sealing plate
– Do not joint the pressure profile at the cross point. Sealing piece
Interior Profile joint
– Length exterior gasket = length pressure profile + 0.5 %. Cover profile for pressure
joint plate sealing plate
– T160 = Joint at intermediate range. no. profile
no. no.
no.
– T161 = Joint at the cross point.
013003 (50x15) 014035 167230 016070
– T163 = Sealing piece for pressure profile.
013210 (50x20) 014035 167232 016070
– T174 = Pressure profile.
013201 (50x25) 014035 167230 016070
– T175 = Cover profile.
Assembly options
013005 (50x25) 014035 167230 016070
– T176 = Pressure profile gasket.
THERM+ S-I
141104 (50x25) 014035 167234 016070
– T177 = Interior joint plate.
141106 (50x30) 014035 167236 016070
– T178 = Profile joint sealing plate.
013023 (56x15) 014036 167250 016071
013410 (56x20) 014036 167252 016071
013400 (56x25) 014036 167250 016071
013025 (56x25) 014036 167250 016071
141304 (56x25) 014036 167254 016071
141307 (56x32) 014036 167257 016071
013610 (76x20) 014037 167272 016072
013050 (76x15) 014037 167270 016072
013615 (76x25) 014037 167274 016072
013620 (76x30) 014037 167276 016072
Assembly options
59° to 45° 152022 152025 152028 152031
– T41 = Notch.
THERM+ S-I
– T155 = Transom gasket. 44° to 35° 152023 152026 152029 152032
– T186 = Self-cutting. For system width 96 mm the transom sealing piece 152056 (for EPDM gaskets) or
152048 (for silicone gaskets) has to be used and sealed with the corresponding
– T188 = Transom sealing piece. sealing material. Cut to size by the customer according to angle.
Selection cross-point sealing plate and pressure profile Assembly example (exterior view)
sealing piece (cut to size by custumer acc. to angle) Positions of the transom sealing pieces left / right
Exterior gasket
5 mm
Cross point Pressure profile Pressure profile
System
sealing plate sealing piece sealing piece
width Transom sealing Transom sealing
no. no. no. piece left piece right
mm
PU = 10 pc(s) PU = 5 pc(s) PU = 5 pc(s)
For pressure and cover profile
50 016080 014080 152402
56 016081 014081 152412
76 016082 014082 152422 Pressure and cover profile
For flat pressure profile
50 016083 014083
56 016084 014084
76 016085 014085
■ Technical information
– RB = Grid width
RH = Grid height.
– T53 = Length flatpressure profile = RB - 51.
– T54 = Length pressure profile with visible
screwed connection = RB - 51.
– T55 = Length cover profile clipped = RB - 51.
– T56 = Length pressure profile = RB - 55.
– T57 = Glass dimensions = RB or RH - 26.
– T58 = Length transom gasket
= RB - 28 + 0.5% add-on.
– T66 = Length of the base profile = RB - 56.
– T274 = Glass dimension passive house = FW or FH - 24.
■ Technical information
– RB = Grid width
RH = Grid height.
– T60 = Length flat pressure profile = RB - 57.
– T61 = Length pressure profile with visible
screwed connection = RB - 57.
– T62 = Length cover profile clipped = RB - 57.
– T63 = Length pressure profile = RB - 61.
Assembly options
– T64 = Glass dimensions = RB or RH - 30.
THERM+ S-I
– T65 = Length transom gasket
= RB - 34 + 0.5 % add-on.
– T115 = Length of the base profile = SW - 66.
– T280 = Glass dimension passive house
= FW or FH - 30.
■ Technical information
T107
– RB = Grid width
RH = Grid height.
– T93 = Length pressure profile = RB - 81.
– T94 = Glass dimensions = RB or RH - 46.
– T95 = Length transom gasket
= RB - 54 + 0.5% add-on.
– T96 = Length profile = RB - 86.
T93
– T107 = Length of the cover profile = RB - 77.
– T116 = Glass dimension = RB or RH - 29.
T94
T116
Passivhaus
Passive mit insulating
house with
Dämmblock
block P 168526
P 168526 and exterior
und 5Außendichtung
gasket mm 5mm
T95
T96
■ Technical information
T97
– RB = Grid width
RH = Grid height.
– T97 = Length cover profile = RB - 97.
– T98 = Length pressure profile = RB - 101.
– T99 = Glass dimensions = RB or RH - 66.
– T100 = Length transom gasket
= RB - 74 + 0.5% add-on.
Assembly options
– T101 = Length profile = RB - 106.
T98
THERM+ S-I
T99
T100
T101
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
Assembly options
THERM+ S-I
Infill thickness RAL 9004 Stainl. steel Length Infill thickness RAL 9004 Stainl. steel Length
mm No. No. mm mm No. No. mm
12 012310 012011 35 12 - 012010 32
13 to 15 012311 012012 38 13 to 15 012310 012011 35
16 to 17 012312 012139 40 16 to 18 012311 012012 38
18 to 19 012313 012013 42 19 to 20 012312 012139 40
20 to 22 012314 012014 45 21 to 22 012313 012013 42
23 to 25 012315 012140 48 23 to 25 012314 012014 45
26 to 27 012316 012015 50 26 to 28 012315 012140 48
28 to 29 012317 012141 52 29 to 30 012316 012015 50
30 to 32 012318 012016 55 31 to 32 012317 012141 52
33 to 35 012319 012142 58 33 to 35 012318 012016 55
36 to 37 012320 012017 60 36 to 38 012319 012142 58
38 to 39 012321 012143 62 39 to 40 012320 012017 60
40 to 42 012322 012018 65 41 to 42 012321 012143 62
43 to 45 012323 012020 68 43 to 45 012322 012018 65
46 to 47 012324 012146 70 46 to 48 012323 012020 68
48 to 49 012325 012147 72 49 to 50 012324 012146 70
50 to 52 012326 012148 75 51 to 52 012325 012147 72
53 to 55 012327 012260 78 53 to 55 012326 012148 75
56 to 57 012328 012149 80 56 to 58 012327 012260 78
58 to 59 012329 012261 82 59 to 60 012328 012149 80
60 to 62 - 012262 85 61 to 62 012329 012261 82
63 to 64 - 012265 88 63 to 64 - 012262 85
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
Assembly options
THERM+ S-I
Infill thickness Length Infill thickness Length Infill thickness Length
No. No. No.
mm mm mm mm mm mm
10 to 11 012107 25 10 to 11 012138 30 10 to 11 012137 28
12 to 14 012108 28 12 to 13 012010 32 12 to 13 012138 30
15 to 16 012109 30 14 to 16 012011 35 14 to 16 012010 32
17 to 18 012110 32 17 to 19 012012 38 17 to 19 012011 35
19 to 21 012111 35 20 to 21 012139 40 20 to 21 012012 38
22 to 24 012112 38 22 to 23 012013 42 22 to 23 012139 40
25 to 26 012113 40 24 to 26 012014 45 24 to 26 012013 42
27 to 28 012114 42 27 to 29 012140 48 27 to 29 012014 45
29 to 31 012115 45 30 to 31 012015 50 30 to 31 012140 48
32 to 34 012116 48 32 to 33 012141 52 32 to 33 012015 50
35 to 36 012117 50 34 to 36 012016 55 34 to 36 012141 52
37 to 38 012118 52 37 to 39 012142 58 37 to 39 012016 55
39 to 41 012119 55 40 to 41 012017 60 40 to 41 012142 58
42 to 44 012129 58 42 to 43 012143 62 42 to 43 012017 60
45 to 46 012123 60 44 to 46 012018 65 44 to 46 012143 62
47 to 48 012124 62 47 to 49 012020 68 47 to 49 012018 65
49 to 51 012125 65 50 to 51 012146 70 50 to 51 012020 68
52 to 54 012106 68 52 to 53 012147 72 52 to 53 012146 70
55 to 56 012126 70 54 to 56 012148 75 54 to 56 012147 72
57 to 58 012144 72 57 to 59 012260 78 57 to 59 012148 75
59 to 61 012127 75 60 to 61 012149 80 60 to 61 012260 78
62 to 64 012200 78 62 to 63 012261 82 62 to 63 012149 80
64 012262 85 64 012261 82
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
Infill thickness RAL 9004 Stainl. steel Length Infill thickness RAL 9004 Stainl. steel Length
mm No. No. mm mm No. No. mm
10 to 11 012310 012011 35 10 to 11 - 012010 32
12 to 14 012311 012012 38 12 to 14 012310 012011 35
15 to 16 012312 012139 40 15 to 17 012311 012012 38
17 to 18 012313 012013 42 18 to 19 012312 012139 40
19 to 21 012314 012014 45 20 to 21 012313 012013 42
22 to 24 012315 012140 48 22 to 24 012314 012014 45
25 to 26 012316 012015 50 25 to 27 012315 012140 48
27 to 28 012317 012141 52 28 to 29 012316 012015 50
29 to 31 012318 012016 55 30 to 31 012317 012141 52
32 to 34 012319 012142 58 32 to 34 012318 012016 55
35 to 36 012320 012017 60 35 to 37 012319 012142 58
37 to 38 012321 012143 62 38 to 39 012320 012017 60
39 to 41 012322 012018 65 40 to 41 012321 012143 62
42 to 44 012323 012020 68 42 to 44 012322 012018 65
45 to 46 012324 012146 70 45 to 47 012323 012020 68
47 to 48 012325 012147 72 48 to 49 012324 012146 70
49 to 51 012326 012148 75 50 to 51 012325 012147 72
52 to 54 012327 012260 78 52 to 54 012326 012148 75
55 to 56 012328 012149 80 55 to 57 012327 012260 78
57 to 58 012329 012261 82 58 to 59 012328 012149 80
59 to 61 - 012262 85 60 to 61 012329 012261 82
62 to 64 - 012265 88 62 to 64 - 012262 85
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
Assembly options
THERM+ S-I
Infill thickness Length Infill thickness Length
No. No.
mm mm mm mm
10 012238 35 10 012237 32
11 to 13 012212 38 11 to 13 012238 35
14 to 15 012239 40 14 to 16 012212 38
16 to 17 012213 42 17 to 18 012239 40
18 to 20 012214 45 19 to 20 012213 42
21 to 23 012240 48 21 to 23 012214 45
24 to 25 012215 50 24 to 26 012240 48
26 to 27 012241 52 27 to 28 012215 50
28 to 30 012216 55 29 to 30 012241 52
31 to 33 012242 58 31 to 55 012216 55
34 to 35 012217 60 34 to 58 012242 58
36 to 37 012243 62 37 to 38 012217 60
38 to 40 012218 65 39 to 40 012243 62
41 to 43 012219 68 41 to 43 012218 65
44 to 45 012244 70 44 to 46 012219 68
46 to 47 012220 72 47 to 48 012244 70
48 to 50 012245 75 49 to 50 012220 72
51 to 53 012221 78 51 to 53 012245 75
54 to 55 012246 80 54 to 56 012221 78
56 to 57 012222 82 57 to 58 012246 80
58 to 60 012223 85 59 to 60 012222 82
61 to 63 012263 88 61 to 63 012223 85
64 012264 90 64 012263 88
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
– For flat pressure profile – For flat pressure profile – For flat pressure profile
no. 013300, 013310, 013313. no. 013300, 013310, 013313. no. 013300, 013310, 013313.
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
Assembly options
THERM+ S-I
Infill Stainl. Infill thickness Length
RAL 9004 Length No.
thickn. steel mm mm
No. mm
mm No. 22 to 24 012212 38
22 to 23 012310 012011 35 25 to 26 012239 40
24 to 26 012311 012012 38 27 to 28 012213 42
27 to 28 012312 012139 40 29 to 31 012214 45
29 to 30 012313 012013 42 32 to 34 012240 48
31 to 33 012314 012014 45 35 to 36 012215 50
34 to 36 012315 012140 48 37 to 38 012241 52
37 to 38 012316 012015 50 39 to 41 012216 55
39 to 40 012317 012141 52 42 to 44 012242 58
41 to 43 012318 012016 55 45 to 46 012217 60
44 to 46 012319 012142 58 47 to 48 012243 62
47 to 48 012320 012017 60 49 to 51 012218 65
49 to 50 012321 012143 62 52 to 54 012219 68
51 to 53 012322 012018 65 55 to 56 012244 70
54 to 56 012323 012020 68 57 to 58 012220 72
57 to 58 012324 012146 70 59 to 61 012245 75
59 to 60 012325 012147 72 62 to 64 012221 78
61 to 63 012326 012148 75
64 012327 012260 78
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
Assembly options
THERM+ S-I
Infill thickness RAL 9004 Stainl. steel Length Infill thickness RAL 9004 Stainl. steel Length
mm No. No. mm mm No. No. mm
4 to 5 012311 012012 38 4 to 5 012310 012011 35
6 to 7 012312 012139 40 6 to 8 012311 012012 38
8 to 9 012313 012013 42 9 to 10 012312 012139 40
10 to 12 012314 012014 45 11 to 12 012313 012013 42
13 to 15 012315 012140 48 13 to 15 012314 012014 45
16 to 17 012316 012015 50 16 to 18 012315 012140 48
18 to 19 012317 012141 52 19 to 20 012316 012015 50
20 012318 012016 55
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11 and 13 extended screws must be used.
– The actual infill thickness should be noted.
– When using the aluminium base profile, the screw lengths have to be selected based on the planning manuals
for THERM+ H-I or THERM+ A-I.
Assembly options
– Max. usability force FH regarding to one pair of sockets. 169966 66 169906 20
THERM+ S-I
– Max. usability force FH is constant at every load distance → FH = 0.80 kN. 169970 70 169907 22
– A force crosswise to the mullion cannot be taken → FQ = 0 kN. 169974 74 169908 24
– The indicated loads are dimensioning loads. 169978 78 169909 26
– A connection plate by the customer (min. 40 x 10 mm) is used 169982 82 169910 28
for leading the forces into the the screws. 169986 86 169911 30
– The screws 5.5 has to be bolted with a bolting torque of min. 8 Nm. 169990 90 169912 32
169994 94 169913 34
– The fixation of sun protection can only be used by pairs.
169998 98 169914 36
– For each assembling situation a statical calculation is mandatory.
169999 102 169915 38
The influencing variables of EUROCODE 1 and DIN 1055 have
to be considered. 169917 42
169918 44
– T13 = Infill thickness.
169919 46
– T33 = Fixation of sun protection.
– T34 = Length of socket.
– T35 = Offset point of application a.
– T185 = Dimensioning example for connection plate provided by customer.
– T224 = See table.
to
Screw distance 90 mm
Vertical force
in use Fv [kN]
■ Technical information 1.30
1.30 1.30
1.25 1.25
1.20 1.20
1.15 1.15
1.10 1.10
1.05 1.05
1.00 1.00
0.95 0.95
0.90 0.90
0.85 0.85
0.80 0.80
0.75 0.75
0.70 0.70
0.65 0.65
0.60 0.60
0.55 0.55
0.50 0.50
0.45 0.45
0.40 0.40
0.35 0.35
0.30 0.30
Length of Length of
socket [mm] socket [mm]
1.30 1.30
1.25 1.25
1.20 1.20
1.15 1.15
1.10 1.10
1.05 1.05
1.00 1.00
0.95 0.95
0.90 0.90
0.85 0.85
0.80 0.80
0.75 0.75
0.70 0.70
0.65 0.65
0.60 0.60
0.55 0.55
0.50 0.50
0.45 0.45
0.40 0.40
0.35 0.35
0.30 0.30
Length of Length of
socket [mm] socket [mm]
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 013004 (50 mm)
No. 013024 (56 mm)
No. 013051 (76 mm)
Assembly options
– T74 = Infill thickness.
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
20 169942 169903
21 to 22 169946 169904
23 to 24 169946 169903
25 to 26 169950 169904
27 to 28 169950 169903
29 to 30 169954 169904
31 to 32 169954 169903
33 to 34 169958 169904
35 to 36 169958 169903
37 to 38 169962 169904
39 to 40 169962 169903
T74
41 to 42 169966 169904
43 to 44 169966 169903
45 to 46 169970 169904
47 to 48 169970 169903
49 to 50 169974 169904
51 to 52 169974 169903
53 to 54 169978 169904
55 to 56 169978 169903
57 to 58 169982 169904
59 to 60 169982 169903
61 to 62 169986 169904
63 to 64 169986 169903
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 013004 (50 mm)
No. 013024 (56 mm)
No. 013051 (76 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169946 169904
22 to 23 169946 169903
24 to 25 169950 169904
26 to 27 169950 169903
28 to 29 169954 169904
30 to 31 169954 169903
32 to 33 169958 169904
34 to 35 169958 169903
36 to 37 169962 169904
38 to 39 169962 169903
40 to 41 169966 169904
T74
42 to 43 169966 169903
44 to 45 169970 169904
46 to 47 169970 169903
48 to 49 169974 169904
50 to 51 169974 169903
52 to 53 169978 169904
54 to 55 169978 169903
56 to 57 169982 169904
58 to 59 169982 169903
60 to 61 169986 169904
62 to 63 169986 169903
64 169990 169904
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 141101 (50 mm)
No. 141301 (56 mm)
No. 141501 (76 mm)
Assembly options
– T74 = Infill thickness.
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
20 169946 169905
21 to 22 169946 169904
23 to 24 169950 169905
25 to 26 169950 169904
27 to 28 169954 169905
29 to 30 169954 169904
31 to 32 169958 169905
33 to 34 169958 169904
35 to 36 169962 169905
37 to 38 169962 169904
39 to 40 169966 169905
41 to 42 169966 169904
43 to 44 169970 169905
45 to 46 169970 169904
47 to 48 169974 169905
49 to 50 169974 169904
51 to 52 169978 169905
53 to 54 169978 169904
55 to 56 169982 169905
57 to 58 169982 169904
59 to 60 169986 169905
61 to 62 169986 169904
63 to 64 169990 169905
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 141101 (50 mm)
No. 141301 (56 mm)
No. 141501 (76 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169946 169904
22 to 23 169950 169905
24 to 25 169950 169904
26 to 27 169954 169905
28 to 29 169954 169904
30 to 31 169958 169905
32 to 33 169958 169904
34 to 35 169962 169905
36 to 37 169962 169904
38 to 39 169966 169905
40 to 41 169966 169904
42 to 43 169970 169905
44 to 45 169970 169904
46 to 47 169974 169905
48 to 49 169974 169904
50 to 51 169978 169905
52 to 53 169978 169904
54 to 55 169982 169905
56 to 57 169982 169904
58 to 59 169986 169905
60 to 61 169986 169904
62 to 63 169990 169905
64 169990 169904
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
No. 118020 (96 mm)
– Cover profiles:
No. 013003 (50 mm)
No. 013023 (56 mm)
Assembly options
No. 013050 (76 mm)
No. 141710 (96 mm)
THERM+ S-I
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169946 169905
21 169946 169904
22 169950 169906
23 to 24 169950 169905
25 169950 169904
26 169954 169906
27 to 28 169954 169905
29 169954 169904
30 169958 169906
31 to 32 169958 169905
33 169958 169904
34 169962 169906
35 to 36 169962 169905
37 169962 169904
38 169966 169906
39 to 40 169966 169905
41 169966 169904
42 169970 169906
43 to 44 169970 169905
45 169970 169904
46 169974 169906
47 to 48 169974 169905
49 169974 169904
50 169978 169906
51 to 52 169978 169905
53 169978 169904
54 169982 169906
55 to 56 169982 169905
57 169982 169904
58 169986 169906
59 to 60 169986 169905
61 169986 169904
62 169990 169906
63 to 64 169990 169905
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
No. 118020 (96 mm)
– Cover profiles:
No. 013003 (50 mm)
No. 013023 (56 mm)
No. 013050 (76 mm)
No. 141710 (96 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169946 169904
21 169950 169906
22 to 23 169950 169905
24 169950 169904
25 169954 169906
26 to 27 169954 169905
28 169954 169904
29 169958 169906
30 to 31 169958 169905
32 169958 169904
33 169962 169906
34 to 35 169962 169905
36 169962 169904
37 169966 169906
38 to 39 169966 169905
40 169966 169904
41 169970 169906
42 to 43 169970 169905
44 169970 169904
45 169974 169906
46 to 47 169974 169905
48 169974 169904
49 169978 169906
50 to 51 169978 169905
52 169978 169904
53 169982 169906
54 to 55 169982 169905
56 169982 169904
57 169986 169906
58 to 59 169986 169905
60 169986 169904
61 169990 169906
62 to 63 169990 169905
64 169990 169904
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 013210 (50 mm)
No. 013410 (56 mm)
No. 013610 (76 mm)
Assembly options
– T74 = Infill thickness.
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
20 169950 169907
21 to 22 169954 169908
23 to 24 169954 169907
25 to 26 169958 169908
27 to 28 169958 169907
29 to 30 169962 169908
31 to 32 169962 169907
33 to 34 169966 169908
35 to 36 169966 169907
37 to 38 169970 169908
39 to 40 169970 169907
41 to 42 169974 169908
43 to 44 169974 169907
T74
45 to 46 169978 169908
47 to 48 169978 169907
49 to 50 169982 169908
51 to 52 169982 169907
53 to 54 169986 169908
55 to 56 169986 169907
57 to 58 169990 169908
59 to 60 169990 169907
61 to 62 169994 169908
63 to 64 169994 169907
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 013210 (50 mm)
No. 013410 (56 mm)
No. 013610 (76 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169954 169908
22 to 23 169954 169907
24 to 25 169958 169908
26 to 27 169958 169907
28 to 29 169962 169908
30 to 31 169962 169907
32 to 33 169966 169908
34 to 35 169966 169907
36 to 37 169970 169908
38 to 39 169970 169907
40 to 41 169974 169908
42 to 43 169974 169907
44 to 45 169978 169908
T74
46 to 47 169978 169907
48 to 49 169982 169908
50 to 51 169982 169907
52 to 53 169986 169908
54 to 55 169986 169907
56 to 57 169990 169908
58 to 59 169990 169907
60 to 61 169994 169908
62 to 63 169994 169907
64 169998 169908
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 141104 (50 mm)
No. 141304 (56 mm)
No. 013615 (76 mm)
Assembly options
– T74 = Infill thickness.
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169958 169911
22 to 23 169958 169910
24 to 25 169962 169911
26 to 27 169962 169910
28 to 29 169966 169911
30 to 31 169966 169910
32 to 33 169970 169911
34 to 35 169970 169910
36 to 37 169974 169911
38 to 39 169974 169910
40 to 41 169978 169911
42 to 43 169978 169910
44 to 45 169982 169911
46 to 47 169982 169910
48 to 49 169986 169911
50 to 51 169986 169910
52 to 53 169990 169911
54 to 55 169990 169910
56 to 57 169994 169911
58 to 59 169994 169910
60 to 61 169998 169911
62 to 63 169998 169910
64 169999 169911
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 141104 (50 mm)
No. 141304 (56 mm)
No. 013615 (76 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169958 169911
21 to 22 169958 169910
23 to 24 169962 169911
25 to 26 169962 169910
27 to 28 169966 169911
29 to 30 169966 169910
31 to 32 169970 169911
33 to 34 169970 169910
35 to 36 169974 169911
37 to 38 169974 169910
39 to 40 169978 169911
41 to 42 169978 169910
43 to 44 169982 169911
45 to 46 169982 169910
47 to 48 169986 169911
49 to 50 169986 169910
51 to 52 169990 169911
53 to 54 169990 169910
55 to 56 169994 169911
57 to 58 169994 169910
59 to 60 169998 169911
61 to 62 169998 169910
63 to 64 169999 169911
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 141106 (50 mm)
No. 013620 (76 mm)
– T74 = Infill thickness.
Assembly options
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
20 169962 169913
21 to 22 169962 169912
23 to 24 169966 169913
25 to 26 169966 169912
27 to 28 169970 169913
29 to 30 169970 169912
31 to 32 169974 169913
33 to 34 169974 169912
35 to 36 169978 169913
37 to 38 169978 169912
39 to 40 169982 169913
41 to 42 169982 169912
43 to 44 169986 169913
45 to 46 169986 169912
47 to 48 169990 169913
49 to 50 169990 169912
51 to 52 169994 169913
53 to 54 169994 169912
55 to 56 169998 169913
57 to 58 169998 169912
59 to 60 169999 169913
61 to 62 169999 169912
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 141106 (50 mm)
No. 013620 (76 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169962 169912
22 to 23 169966 169913
24 to 25 169966 169912
26 to 27 169970 169913
28 to 29 169970 169912
30 to 31 169974 169913
32 to 33 169974 169912
34 to 35 169978 169913
36 to 37 169978 169912
38 to 39 169982 169913
40 to 41 169982 169912
42 to 43 169986 169913
44 to 45 169986 169912
46 to 47 169990 169913
48 to 49 169990 169912
50 to 51 169994 169913
52 to 53 169994 169912
54 to 55 169998 169913
56 to 57 169998 169912
58 to 59 169999 169913
60 to 61 169999 169912
■ Technical information
– Pressure profiles:
No. 118010 (56 mm)
– Cover profiles:
No. 141307 (56 mm)
– T74 = Infill thickness.
Assembly options
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
20 169962 169913
21 to 22 169966 169914
23 to 24 169966 169913
25 to 26 169970 169914
27 to 28 169970 169913
29 to 30 169974 169914
31 to 32 169974 169913
33 to 34 169978 169914
35 to 36 169978 169913
37 to 38 169982 169914
39 to 40 169982 169913
41 to 42 169986 169914
43 to 44 169986 169913
45 to 46 169990 169914
47 to 48 169990 169913
49 to 50 169994 169914
51 to 52 169994 169913
53 to 54 169998 169914
55 to 56 169998 169913
57 to 58 169999 169914
59 to 60 169999 169913
■ Technical information
– Pressure profiles:
No. 118010 (56 mm)
– Cover profiles:
No. 141307 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169966 169914
22 to 23 169966 169913
24 to 25 169970 169914
26 to 27 169970 169913
28 to 29 169974 169914
30 to 31 169974 169913
32 to 33 169978 169914
34 to 35 169978 169913
36 to 37 169982 169914
38 to 39 169982 169913
40 to 41 169986 169914
42 to 43 169986 169913
44 to 45 169990 169914
46 to 47 169990 169913
48 to 49 169994 169914
50 to 51 169994 169913
52 to 53 169998 169914
54 to 55 169998 169913
56 to 57 169999 169914
58 to 59 169999 169913
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 013005 (50 mm)
No. 013025 (56 mm)
No. 141505 (76 mm)
Assembly options
No. 013201 (50 mm)
THERM+ S-I
No. 013400 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169954 169909
21 to 22 169954 169908
23 169954 169907
24 169958 169909
25 to 26 169958 169908
27 169958 169907
28 169962 169909
29 to 30 169962 169908
31 169962 169907
32 169966 169909
33 to 34 169966 169908
35 169966 169907
36 169970 169909
37 to 38 169970 169908
39 169970 169907
40 169974 169909
41 to 42 169974 169908
43 169974 169907
44 169978 169909
45 to 46 169978 169908
47 169978 169907
48 169982 169909
49 to 50 169982 169908
51 169982 169907
T74
52 169986 169909
53 to 54 169986 169908
55 169986 169907
56 169990 169909
57 to 58 169990 169908
59 169990 169907
60 169994 169909
61 to 62 169994 169908
63 169994 169907
64 169998 169909
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
No. 118015 (76 mm)
– Cover profiles:
No. 013005 (50 mm)
No. 013025 (56 mm)
No. 141505 (76 mm)
No. 013201 (50 mm)
No. 013400 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169954 169908
22 169954 169907
23 169958 169909
24 to 25 169958 169908
26 169958 169907
27 169962 169909
28 to 29 169962 169908
30 169962 169907
31 169966 169909
32 to 33 169966 169908
34 169966 169907
35 169970 169909
36 to 37 169970 169908
38 169970 169907
39 169974 169909
40 to 41 169974 169908
42 169974 169907
43 169978 169909
44 to 45 169978 169908
46 169978 169907
47 169982 169909
48 to 49 169982 169908
50 169982 169907
51 169986 169909
T74
52 to 53 169986 169908
54 169986 169907
55 169990 169909
56 to 57 169990 169908
58 169990 169907
59 169994 169909
60 to 61 169994 169908
62 169994 169907
63 169998 169909
64 169998 169908
■ Technical information
– Pressure profiles:
No. 013018 (50 mm)
No. 013038 (56 mm)
No. 013068 (76 mm)
No. 142770 (96 mm)
– T74 = Infill thickness.
Assembly options
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
20 169942 169900
21 to 22 169946 169902
23 169946 169901
24 169946 169900
25 to 26 169950 169902
27 169950 169901
28 169950 169900
29 to 30 169954 169902
31 169954 169901
32 169954 169900
33 to 34 169958 169902
35 169958 169901
36 169958 169900
37 to 38 169962 169902
39 169962 169901
40 169962 169900
41 to 42 169966 169902
43 169966 169901
44 169966 169900
45 to 46 169970 169902
47 169970 169901
48 169970 169900
49 to 50 169974 169902
51 169974 169901
52 169974 169900
53 to 54 169978 169902
55 169978 169901
56 169978 169900
57 to 58 169982 169902
59 169982 169901
60 169982 169900
61 to 62 169986 169902
63 169986 169901
64 169986 169900
■ Technical information
– Pressure profiles:
No. 013018 (50 mm)
No. 013038 (56 mm)
No. 013068 (76 mm)
No. 142770 (96 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169946 169902
22 169946 169901
23 169946 169900
24 to 25 169950 169902
26 169950 169901
27 169950 169900
28 to 29 169954 169902
30 169954 169901
31 169954 169900
32 to 33 169958 169902
34 169958 169901
35 169958 169900
36 to 37 169962 169902
38 169962 169901
39 169962 169900
40 to 41 169966 169902
42 169966 169901
43 169966 169900
44 to 45 169970 169902
46 169970 169901
47 169970 169900
48 to 49 169974 169902
50 169974 169901
51 169974 169900
52 to 53 169978 169902
54 169978 169901
55 169978 169900
56 to 57 169982 169902
58 169982 169901
59 169982 169900
60 to 61 169986 169902
62 169986 169901
63 169986 169900
64 169990 169902
■ Technical information
– Pressure profiles:
No. 013008 (50 mm)
No. 013028 (56 mm)
– T74 = Infill thickness.
Assembly options
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
20 169946 169902
21 to 22 169946 169901
23 169946 169900
24 169950 169902
25 to 26 169950 169901
27 169950 169900
28 169954 169902
29 to 30 169954 169901
31 169954 169900
32 169958 169902
33 to 34 169958 169901
35 169958 169900
36 169962 169902
37 to 38 169962 169901
39 169962 169900
40 169966 169902
41 to 42 169966 169901
43 169966 169900
44 169970 169902
45 to 46 169970 169901
47 169970 169900
48 169974 169902
49 to 50 169974 169901
51 169974 169900
52 169978 169902
53 to 54 169978 169901
55 169978 169900
56 169982 169902
57 to 58 169982 169901
59 169982 169900
60 169986 169902
61 to 62 169986 169901
63 169986 169900
64 169990 169902
■ Technical information
– Pressure profiles:
No. 013008 (50 mm)
No. 013028 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169946 169901
22 169946 169900
23 169950 169902
24 to 25 169950 169901
26 169950 169900
27 169954 169902
28 to 29 169954 169901
30 169954 169900
31 169958 169902
32 to 33 169958 169901
34 169958 169900
35 169962 169902
36 to 37 169962 169901
38 169962 169900
39 169966 169902
40 to 41 169966 169901
42 169966 169900
43 169970 169902
44 to 45 169970 169901
46 169970 169900
47 169974 169902
48 to 49 169974 169901
50 169974 169900
51 169978 169902
52 to 53 169978 169901
54 169978 169900
55 169982 169902
56 to 57 169982 169901
58 169982 169900
59 169986 169902
60 to 61 169986 169901
62 169986 169900
63 169990 169902
64 169990 169901
■ Technical information
– Pressure profiles:
No. 013007 (50 mm)
No. 013027 (56 mm)
– T74 = Infill thickness.
Assembly options
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
20 169946 169900
21 169950 169902
22 to 23 169950 169901
24 169950 169900
25 169954 169902
26 to 27 169954 169901
28 169954 169900
29 169958 169902
30 to 31 169958 169901
32 169958 169900
33 169962 169902
34 to 35 169962 169901
T74
36 169962 169900
37 169966 169902
38 to 39 169966 169901
40 169966 169900
41 169970 169902
42 to 43 169970 169901
44 169970 169900
45 169974 169902
46 to 47 169974 169901
48 169974 169900
49 169978 169902
50 to 51 169978 169901
52 169978 169900
53 169982 169902
54 to 55 169982 169901
56 169982 169900
57 169986 169902
58 to 59 169986 169901
60 169986 169900
61 169990 169902
62 to 63 169990 169901
64 169990 169900
■ Technical information
– Pressure profiles:
No. 013007 (50 mm)
No. 013027 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169950 169902
21 to 22 169950 169901
23 169950 169900
24 169954 169902
25 to 26 169954 169901
27 169954 169900
28 169958 169902
29 to 30 169958 169901
31 169958 169900
32 169962 169902
33 to 34 169962 169901
35 169962 169900
T74
36 169966 169902
37 to 38 169966 169901
39 169966 169900
40 169970 169902
41 to 42 169970 169901
43 169970 169900
44 169974 169902
45 to 46 169974 169901
47 169974 169900
48 169978 169902
49 to 50 169978 169901
51 169978 169900
52 169982 169902
53 to 54 169982 169901
55 169982 169900
56 169986 169902
57 to 58 169986 169901
59 169986 169900
60 169990 169902
61 to 62 169990 169901
63 169990 169900
64 169994 169902
■ Technical information
– Pressure profiles:
No. 013014 (50 mm)
– T74 = Infill thickness.
Assembly options
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
20 169954 169906
21 to 22 169954 169905
23 169954 169904
24 to 25 169958 169906
26 169958 169905
27 169958 169904
28 169962 169906
29 to 30 169962 169905
31 169962 169904
32 169966 169906
33 to 34 169966 169905
35 169966 169904
36 169970 169906
37 to 38 169970 169905
39 169970 169904
T74
40 169974 169906
41 to 42 169974 169905
43 169974 169904
44 169978 169906
45 to 46 169978 169905
47 169978 169904
48 169982 169906
49 to 50 169982 169905
51 169982 169904
52 169986 169906
53 to 54 169986 169905
55 169986 169904
56 169990 169906
57 to 58 169990 169905
59 169990 169904
60 169994 169906
61 to 62 169994 169905
63 169994 169904
64 169998 169906
■ Technical information
– Pressure profiles:
No. 013014 (50 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169954 169905
22 169954 169904
23 169958 169906
24 to 25 169958 169905
26 169958 169904
27 169962 169906
28 to 29 169962 169905
30 169962 169904
31 169966 169906
32 to 33 169966 169905
34 169966 169904
35 169970 169906
36 to 37 169970 169905
38 169970 169904
39 169974 169906
T74
40 to 41 169974 169905
42 169974 169904
43 169978 169906
44 to 45 169978 169905
46 169978 169904
47 169982 169906
48 to 49 169982 169905
50 169982 169904
51 169986 169906
52 to 53 169986 169905
54 169986 169904
55 169990 169906
56 to 57 169990 169905
58 169990 169904
59 169994 169906
60 to 61 169994 169905
62 169994 169904
63 169998 169906
64 169998 169905
■ Technical information
– Pressure profiles:
No. 013300 (50 mm)
No. 013310 (56 mm)
No. 013313 (76 mm)
– T74 = Infill thickness.
Assembly options
THERM+ S-I
Selection of sockets and sealing sleeves
Infill thickness
No. socket No. sealing sleeve
mm
24 to 25 169942 169901
26 169942 169900
27 169946 169902
28 to 29 169946 169901
30 169946 169900
31 169950 169902
32 to 33 169950 169901
34 169950 169900
35 169954 169902
36 to 37 169954 169901
38 169954 169900
39 169958 169902
40 to 41 169958 169901
42 169958 169900
43 169962 169902
44 to 45 169962 169901
46 169962 169900
47 169966 169902
48 to 49 169966 169901
50 169966 169900
51 169970 169902
52 to 53 169970 169901
54 169970 169900
55 169974 169902
56 to 57 169974 169901
58 169974 169900
59 169978 169902
60 to 61 169978 169901
62 169978 169900
63 169982 169902
64 169982 169901
■ Technical information
– In the scaffolding fixation area the base profile scaffolding fixation
no. 167793 (50) or no. 167794 (56) has to be mounted.
– Application of flat pressure profile possible from an infill thickness of 32 mm.
– The number and position of the fixation points depends on the specific requirements
of the scaffold. The max. load transmission into the curtain wall construction is
system independant and can be taken from the table Representative parameter.
– T183 = Offset posts.
– T184 = Height of scaffold.
– T281 = Black.
– T282 = White.
– T283 = Scaffolding fixation I.
– T284 = Installation example for transom.
– T303 = Situation after removing the eye bolt. Representative parameter
T283
T303
Assembly options
variables of DIN 1055 has to be considered. Fv [kN] 8.0 7.0 6.0 5.0 4.0 3.0 2.0 1.0
THERM+ S-I
– Please consider several international, national, Fh [kN] 0.2 2.0 3.5 5.0 7.0 8.5 10.0 12.0
regional and local laws and rules.
Diagonal pull Fd in consideration
– The common and accepted rules of technique of angle α
have to be considered. (offset action point a = 100)
– T3 = Steel insertion profile of S235 α [°] 50 45 40 35 30
(for self-production). Fd [kN] 10.0 10.0 10.0 10.0 10.5
– T68 = Offset action point a.
– T69 = Fixation bracket.
– T164 = Built-in conditions.
– T165 = Presentation without glass
and exterior gasket.
■ Technical information
– Applicable for structural profile width
from 50 to 60 mm.
– Mounting bracket optional with fixation bracket
profile 110/120 no. 146005 (in-house production)
or fixation bracket 80 no. 166005 (pre-fabricated).
– Mounting
- 2 mounting units no. 166110.
– Mullion handling
- 2 roand holes Ø 15 mm, offset 40 mm.
– During the detailed planning a statical proof
has to be provided (edge distances, hole bearings
etc. of the structural profile have to be observed).
For detailed information see Processing.
Upper mullion
Approvable loads for fixation bracket
no. 166010 with mounting unit no. 166115
■ Technical information
– Applicable for structural profile width from 50 to 60 mm.
– Mounting bracket optional with fixation bracket
profile 110/120 no. 146005 (in-house production)
or fixation bracket 140 no. 166010 (pre-fabricated).
– Mounting
- 1 mounting unit no. 166115.
– Handling upper mullion
- 2 roand holes Ø 15 mm, offset 43 mm.
Assembly options
– Handling lower mullion
THERM+ S-I
- 1 roand hole Ø 15 mm.
6
– During the detailed planning a statical proof has to be +5
50
provided (edge distances, hole bearings etc. of the of ile
l pr
ra
structural profile have to be observed). ru
c tu
St
For detailed information see Processing.
56
le
of i
l pr
ct ur a
ru
St
Lower mullion
Approvable loads fixation bracket 166010
with mounting unit 166115
Compensation of tolerances
Approvable Floating-point Floating-point
loads fixing 50 fixing 56
FS: 5.2 kN 7.4 kN
FD: 5.2 kN 7.4 kN
FV: 0 kN 0 kN
Compensation of tolerances
■ Technical information
– Applicable for structural profile width from 50 to 60 mm.
– Mounting bracket optional with fixation bracket
profile 110/120 no. 146005 (in-house production)
or fixation bracket 120 no. 166015 (pre-fabricated).
– Mounting
- 1 mounting unit no. 166110.
– Mullion handling
- 1 roand hole Ø 15 mm.
Assembly options
– During the detailed planning a statical proof
THERM+ S-I
has to be provided (edge distances, hole bearings etc. of the structu-
ral profile have to be observed).. For detailed information see
Processing.
■ Technical information
– T74 = Infill thickness.
– T248 = Compensation gasket.
Connection profile no. 168005 with 2 mm sheet Connection profile no. 168005 with 3 mm sheet
Assembly options
THERM+ S-I
Selection compensation gasket Selection compensation gasket
No.
168005
Infill Compensation
Height
thickness gasket PU
mm
mm mm
22 – – –
24 011080 2 100 m
25 011070 3 100 m
26 011077 4 100 m
27 011073 5 100 m
28 011076 6 100 m
29 011074 7 100 m
30 011071 8 100 m
31 011075 9 100 m
33 011072 11 100 m
35 011078 13 50 m
Assembly options
22 011074 7
before the execution.
THERM+ S-I
23 011071 8
– IT = Infill thickness. 24 011075 9
– For more in for mation see Processing. 25 – – –
– T13 = Infill thickness (IT). 26 011072 11 100 m
– T221 = Alternative. 27 – – –
– T261 = Screw, on-site. 28 011078 13 50 m
Difference D between the two glass infill thicknesses is
necessary for the selection.
(D = IT1 minus IT2; IT1 = 20 to 64 mm, IT2 = 2 to 46 mm).
■ Technical information
– Applicable as an assembly aid or for the fixation of
sheets and connection profiles at hard-to-reach places.
– Clamp thickness 1.5 to 3 mm.
– Fixation with a suitable screw for hole Ø 6 mm.
– T261 = Screw, on-site.
■ Technical information
– Table for the selection of the compensation gasket see following page.
– The maximum weight of the slim pane above is to be coordinated with RAICO.
– A difference between the glass thicknesses from 10 to 24 mm can be
compensated without exterior glass offset.
– Ensure the tightness of the compensation profiles in the corners
by carefully sealing them.
– T13 = Infill thickness (IT).
Assembly options
THERM+ S-I
and
296
IT 1 IT 2 (mm)
(mm) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54
16 220322 220321 220320
Accessories
2017
18 220323 220322 220321 220320
THERM+ S-I
Assembly options
34 to 35 167175
THERM+ S-I
36 to 37 167177
38 to 39 167179
40 to 41 167181
42 to 43 167183
44 to 45 167185
46 to 47 167187
48 to 49 167189
50 to 51 167191
No. 52 167193
167165 to 167193
No.
Assembly options
THERM+ S-I
Assembly angles and screws
FRAME+ 75 WB/WI for THERM+ I
Assembly angle for EPDM Synthetic
IT Screw compensation compensation
mm length / No. 50 mm 56 mm 76 mm gasket profile
36 32 mm 012110 167616 167666 without without without without
37 35 mm 012111 167617 167667 – – – –
38 35 mm 012111 167618 167668 2 mm 227010 without without
39 35 mm 012111 167619 167669 3 mm 227032 without without
40 38 mm 012112 167620 167670 4 mm 227015 without without
41 38 mm 012112 167621 167671 5 mm 227032 without without
42 40 mm 012113 167622 167672 6 mm 227020 without without
43 40 mm 012113 167623 167673 7 mm 227032 without without
44 42 mm 012114 167624 167674 8 mm 227025 without without
self-production
■ Technical information
– For the positioning of assembly
angles see Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness.
– T141 = Selection of assembly angle
and screws see table.
System Profile
width Dim. x Dim. y width
mm mm
50 5 5 50
56 6 4 60
76 6 4 80
■ Technical information
– For the positioning of assembly
angles see Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness.
– T141 = Selection of assembly angle
and screws see table.
Assembly options
– T264 = Gasket optional.
THERM+ S-I
Gap dimensions x1 and x 2
System
Dim. x1 Dim. x 2
width
mm mm
mm
50 4 6.5
56 3 5.5
76 3 5.5
Assembly angle
■ Technical information
– For the positioning of assembly
angles see Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness.
– T141 = Selection of assembly angle
and screws see table.
– T264 = Gasket optional.
System
Dim. x1 Dim. x 2
width
mm mm
mm
50 4 6.5
56 3 5.5
76 3 5.5
Assembly angle
■ Technical information
– For the positioning of assembly 217010
angles see Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness.
– T141 = Selection of assembly angle
and screws see table.
Assembly options
THERM+ S-I
Gap dimensions x and y
System Profile
width Dim. x Dim. y width
mm mm
50 7 5 50
56 6 4 60
76 6 4 80
■ Technical information
– For the positioning of assembly
angles see Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness.
– T141 = Selection of assembly angle
and screws see table.
System Profile
width Dim. x Dim. y width
mm mm
50 9 5 50
56 8 4 60
76 8 4 80
■ Technical information
– For the positioning of assembly
angles see Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness.
– T141 = Selection of assembly angle
and screws see table.
Assembly options
THERM+ S-I
Gap dimensions x and y
System Profile
width Dim. x Dim. y width
mm mm
50 9 5 50
56 8 4 60
76 8 4 80
■ Technical information
– For the positioning of assembly
angles see Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness.
– T141 = Selection of assembly angle
and screws see table.
System Profile
width Dim. x Dim. y width
mm mm
50 20 7.5 50
56 19 6.5 60
76 17 4.5 80
■ Technical information
– Screw connection into the façade in combination
with flat pressure profile: with countersunk screw
DIN EN ISO 14586. Sink assembly angle accordingly
before screwing.
– For the position of assembly angles see shimming
instruction in the Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
Assembly options
angles has to be adjusted.
THERM+ S-I
– *Self-production.
– T13 = Infill thickness (IT).
System Profile
width Dim. x Dim. y width
mm mm
50 12 11 50
56 11 10 60 Selection assembly angle
76 9 8 80
Façade width
No. Article
mm
224540 Assembly angle 50 50
224545 Assembly angle 56 56
224550 Assembly angle 76 76
■ Technical information
– Only insulated glass with UV resistance edge
seal or optional with enameling/screen printing
may be used.
– The necessary infill thicknesses have to be
coordinated with the glass supplier.
– The legal glazing instructions have to be
taken into consideration and if necessary an
approval in individual cases has to be obtained.
– The suction discs can be also used as a
mechanical saving in combination with
the SG2 system for all heights larger than
8 m (min. infill thickness 32 mm).
– From an infill thickness of 23 mm possible
with insulating blocks SG.
– Selection of screws see Screw selection.
– Please consider DIN EN 18008, TRLV and
TRPV.
to
Suction disc set 75 Suction disc set 50/90 Suction disc set 56/90
Art.-Nr. 163807
No. 163807 Art.-Nr. 163810
No. 163810 Art.-Nr. 163812
No. 163812
Art.-Nr. 163809
No. 163809 Art.-Nr. 163811
No. 163811 Art.-Nr. 163813
No. 163813
■ Technical information
– Rotate drilling jig for pre-drilling the belay sheet
180° for pre-drilling the belay sheet.
– Information on the assembly see Processing.
Assembly options
THERM+ S-I
No. 127100
No. 902511
Width Height Ix
No.
mm mm cm4
062010 60 60 29.6
062020 60 90 93.58
062030 60 120 252.3
Influencing
parameter e
System benefits
System sections
System sections
THERM+ FS-I
Building connections 50/56 mm 372
2017 311
312 2017
THERM+ FS-I
System benefits
■ Optimum planning
– Threaded tubes available in many varying dimensions and
wall thicknesses for a wide range of static requirements.
– Vertical curtain wall and glass roof up to 2° roof inclination.
– Different steel connectors for single bar or ladder assembly
System sections
available.
THERM+ FS-I
– Special steel connector even for heavy loads.
– Extensive system accessories.
■ Efficient installation
– Integrated screw channel in tube reduces planning,
manufacturing and installation costs.
– No welding needed for the curtain wall construction.
– Direct mounting of the pressure profile into the steel substructure.
– Sendzimir galvanised profiles ensure a broad corrosion protection.
– Special technology for invisible screwed transom connection
of the steel tubes.
– Two options for interior gaskets.
– Guidance of gasket with one-part synthetic profile.
– Integrated drainage at the continuous gasket in three levels.
– Separation of screw penetration and water-bearing level
by hat gaskets.
■ Guidance of gasket
with one-part synthetic profile
– No slipping of the gaskets.
– Secure fixing of the pressure profile screw
in the steel substructure.
– Slim steel glazing coupled with a reduction
of costly on-site welding.
– Long term quality due to our established
technology.
314 2017
THERM+ FS-I
System benefits
Airborne sound insulation (if specially RW(C;Ctr) = 34 (-1;-4) dB until gbd LAB
4.6
requesed) (EN ISO 140-3) RW(C;Ctr) = 47 (-1;-3) dB Nr. 15/1268_01
System sections
THERM+ FS-I
■ Notice
– All features can be used for CE-Labelling by the manufactures of curtain walls. It is mandatory that only RAICO products has to
be used and the production process has to be monitored by an in-house production control system. The whole production process
has to be compliant to the RAICO assembly instructions.
– Depending on the panel dimensions of the curtain wall and the structural connections the sound insulation value has to be calculated
separately. The system testimonial can only be used for an overview.
– Depending on the different systems options and the glass thickness the Um,t-value can be adapted step-by-step. The exacts values
based on DIN EN ISO 10077-2 are documented in the thermal protection documentations by RAICO.
European technical approval: – Connection steel structural profile European technical approval for OIB, Wien
clamping joint and glass load with system base pofile the fixing system THERM+ steel
transmission for the curtain – T-connection curtain wall
wall system – Glass carriers
– Pressure profiles
– Screws
Glass roof with 2° inclination: Class AE including accessories Test of airpermeability acc. to ift Rosenheim
Air permeability (e. g. sun protection fixation) EN 12153:2000-06 Nr. 15-003223-PR01
Glass roof with 2° inclination: Class RE 2550 including accessories Test of water penetration acc. to ift Rosenheim
Water penetration (e. g. sun protection fixation) EN 12155:2000-06 Nr. 15-003223-PR01
Test load up to 2.6 kN/m2, safety ift Rosenheim
Glass roof with 2° inclination: Test of wind resistance to wind-
up to 3.9 kN/m2 (e. g. sun protection Nr. 15-003223-PR01
Wind resistance load after EN 12179:2000-06
fixation)
Resistance class RC2 Test THERM+ FS-I gbd LAB
Burglar prevention
for system widhts 50 and 56 mm acc. to DIN EN 1627 16/1314_02
2017 315
THERM+ FS-I
System benefits
■ Drainage system
– The drainage groove of the mullion and
transom gasket is arranged on various levels.
– In all THERM+ systems the ventilation and
drainage principle is so designed that a
controlled condensate removal from
transom to the mullion rebate is secured
via interior gaskets.
■ Exterior gasket
– Various exterior gaskets and insulating
Standard exterior gasket
block options available.
– Gradual adaptation of the insulation value.
– Maximum thermal insulation up to
Um,t= 0.75 W/(m²K) including screw influence. Insulating block 9
– Certified passive house curtain wall.
– Economic solution.
Insulating block 21
Insulating block P
System sections
THERM+ FS-I
Insulating block PH
Pfostendichtung
Mullion gasket LL Riegeldichtung
Transom gasketLL
■ Interior gasket options
– Type „S“ for assembly with lateral guidance
and fixation by a synthetic base profile.
– Type „L“ with lateral lips for visual optimization
using big radiuses of structural profiles lateral
guidance like type „S“.
Polygondichtung
Polygon gasket Pfostendichtung
Mullion gasket
Einfachverglaung
single glazing
■ Safety distance
– Patent-registered add-on construction with
integrated screw channel in the structural profile.
– Optimal protection against corrosion by using
sendzimir galvanised profiles.
– No superficially bonded components.
– The completely accessible surface enables an
easy and efficient treatment against corrosion
– even in the screw connection zone.
Base profile
Mullion gasket
System sections
THERM+ FS-I
Base profile
Threaded tube
Base profile
Base profile
glass carrier
Transom gasket
■ Isothermal lines
– Double glazing with Ug=1.1 W/(m2K) and
acrylic spacer.
– Already with standard exterior gaskets the
10°C- isothermal line remains completely
within the system.
THERM+ 50 FS-I
– Condensate is avoided efficiently. with acrylic spacer
– Individual adaption at higher risk of conden-
sation is possible (e. g. conservatories). Due to the outstanding thermal insulation already
with standard gaskets as well as the insulating
effect of acrylic spacers the isothermal line
■ Formation of condensate
does not touch the surface of the structure.
– The humidity in the room can no longer
be absorbed by the air.
– The humidity builds up drops on
building compoments with low surface
temperatures.
– Movement of the drop formation of
insulating glass towards the area of the
spacer an the frame of the curtain wall
system.
– Formation of condensate at standard
conditions with a relative humidity of 50%
and an accepted air temperature of 20°C
in case of a temperature on surfaces
of 10°C.
System sections
THERM+ FS-I
System sections
THERM+ FS-I
to
■ Technical information
– T38 = Level 2.
– T39 = Level 3.
– T40 = Level 1.
– T151 = Interior gasket E3.
– T152 = Interior gasket E2.
– T153 = Interior gasket E1.
– T159 = Interior gasket E2 with flap.
7.5
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
System sections
THERM+ FS-I
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Insulating block PH 50/29 168513 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 43 to 44 162080 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x88 with 909088
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Insulating block P 50/19 168509 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Insulating block 50/21 150605 50 m
System sections
THERM+ FS-I
■ Accessories
Article No. PU
26 - 64 mm
26 - 64 mm
■ Gaskets
Article No. PU
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Insulating block 50/9 151010 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
System sections
THERM+ FS-I
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for press. profile 3 011070.LI 100 m
Gasket for press. profile 3 011070.RE 100 m
Gasket for mullion 50 150005 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Countersunk sheet 100
902805
metal screw 5.5x20 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Profiles
Article No. PU
Cover profile 50/15 013003 6m
Pressure profile 47
118005 6m
punched
Base profile 41 punched 145005 6m
Connection profile 38/22 168121 6m
Base profile 50 168420 6m
Threaded tube 50/90/2 445015 7m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
System sections
011070.RE 100 m
profile 3
THERM+ FS-I
Gasket for mullion 50 150005 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Countersunk sheet 100
902805
metal screw 5.5x20 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for press. profile 3 011070.LI 100 m
Gasket for press. profile 3 011070.RE 100 m
Gasket for mullion 50 150005 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Countersunk sheet 100
902805
metal screw 5.5x20 pc(s)
Flat fillister head screw 100
909073
6.0x73, sealing washer pc(s)
Wall
Surface Weight Height
No. thickn.
area m2 kg/m mm
mm
445010 0.265 4.07 60 2
445015 0.325 5.01 90 2
445020 0.385 5.95 120 2
System sections
445025 0.382 8.79 120 3
THERM+ FS-I
445030 0.442 10.21 150 3
445035 0.440 13.43 150 4
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for transom 50
150015 20 m
with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Compensation gasket 2 011080 100 m
System sections
THERM+ FS-I
Base gasket for transom
150020 20 m
50 with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece
152070 10 pc(s)
for base transom
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crossp. sealing plate 50 016050 10 pc(s)
Sealing pc. for transom 50 152010 100 pc(s)
optional Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Flat fillister head screw
909073 100 pc(s)
6.0x73, sealing washer
Terminal clamp 48/20 915501 100 pc(s)
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
System sections
Gasket for pressure
THERM+ FS-I
011070.RE 100 m
profile 3
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Interior gasket 3 220320 100 m
■ Accessories
Article No. PU
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 33 to 34 162055 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6,0x38 pc(s)
Special flat fillister
100
head screw 6,0x78 with 909078
pc(s)
sealing washer
50
Fixture spring 26/25/10 915015
pc(s)
162055
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 10 to 14 162005 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x58 with 909058
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
System sections
THERM+ FS-I
Gasket for mullion 50/26 150461 20 m
Interior gasket 50/26 E3 150462 20 m
Interior gasket 50/26 E2 150463 20 m
■ Accessories
Article No. PU
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152007
for transom 50/26 pc(s)
Sealing piece 100
152011
for transom 50/26 E2 pc(s)
Glass carrier 10/13 167556 10 pc(s)
Special flat fillister 100
908308
head screw 5.5x19 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x63 with 909063
pc(s)
sealing washer
■ Accessories
Article No. PU
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Accessories
System sections
Article No. PU
THERM+ FS-I
Special flat fillister
100
head screw 6.0x78 with 909078
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for pressure
011805 100 m
profile 5 polygonal
Gasket for mullion 50
150040 20 m
polygonal 8° to 20°
Gasket for mullion 50
150045 20 m
polygonal 21° to 33°
■ Accessories
Article No. PU
Special flat fillister
100
head screw 6.0x83 with 909083
pc(s)
sealing washer
Special flat fillister
100
head screw 6.0x88 with 909088
pc(s)
sealing washer
System sections
■ Accessories
THERM+ FS-I
Article No. PU
Special flat fillister
100
head screw 6.0x88 with 909088
pc(s)
sealing washer
or
■ Accessories
System sections
THERM+ FS-I
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
100
Cover profile fixation 80 167005
pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
System sections
THERM+ FS-I
■ Gaskets
Article No. PU
Gasket for pressure
220205 100 m
profile 2/16
■ Accessories
Article No. PU
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
Special flat fillister
100
head screw 6.0x63 with 909263
pc(s)
sealing ring
Special flat fillister
100
head screw 6.0x73 with 909273
pc(s)
or sealing ring
Special flat fillister
100
head screw 6.0x63 with 909663
pc(s)
sealing ring
Special flat fillister
100
head screw 6.0x73 with 909673
pc(s)
sealing ring
or
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
System sections
THERM+ FS-I
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Insulating block PH
168519 50 m
56/29
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 43 to 44 162080 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x88 with 909088
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Insulating block P 56/19 168515 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Insulating block 56/21 150610 50 m
System sections
THERM+ FS-I
■ Accessories
26 - 64 mm
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 27 to 28 162040 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
26 - 64 mm
■ Gaskets
Article No. PU
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Insulating block 56/9 151020 50 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
System sections
THERM+ FS-I
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister head
100
screw 6.0x73 with 909073
pc(s)
sealing washer
90°
Steel curtain wall
Corner mullion 90°, vertical, wide construction
Mullion section
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Countersunk sheet 100
902805
metal screw 5.5x20 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
90°
Steel curtain wall
THERM+ 56 FS-I with THERM
Corner mullion 90°, vertical - THERM+ THERM+ + 56 S-I
Mullion section
■ Profiles
Article No. PU
Cover profile 56/15 013023 6m
Pressure profile 53
118010 6m
punched
Base profile 47 punched 145010 6m
Connection profile 38/22 168121 6m
Base profile 56 168425 6m
Threaded tube 60/90/2 445065 7m
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
System sections
011070.RE 100 m
profile 3
THERM+ FS-I
Gasket for mullion 56 150105 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Countersunk sheet 100
902805
metal screw 5.5x20 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket f. press. profile 3 011070.LI 100 m
Gasket f. press. profile 3 011070.RE 100 m
Gasket for mullion 56 150105 20 m
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Countersunk sheet 100
902805
metal screw 5.5x20 pc(s)
Flat fillister head screw 100
909073
6.0x73, sealing washer pc(s)
Wall
Surface Weight Height
No. thickn.
area m2 kg/m
System sections
mm
mm
THERM+ FS-I
445060 0.285 4.38 60 2
445065 0.345 5.32 90 2
445070 0.340 10.28 90 4
445075 0.405 6.27 120 2
445080 0.400 12.17 120 4
445085 0.462 10.68 150 3
445090 0.460 14.05 150 4
445095 0.522 12.10 180 3
445100 0.517 19.70 180 5
445105 0.557 21.27 200 5
445100
445100.F10000
445105
445105.F10000
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for transom 56
150115 20 m
with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Compensation gasket 2 011080 100 m
System sections
THERM+ FS-I
Base gasket for transom
150120 20 m
56 with flap
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece
152071 10 pc(s)
for base transom
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Accessories
Article No. PU
Special countersunk sheet
012049 100 pc(s)
metal screw 5.5x24
Sealing pc. f. press. prof. 56 014036 10 pc(s)
Crossp. sealing plate 56 016051 10 pc(s)
Sealing pc. for transom 56 152015 100 pc(s)
optional
Glass carrier 25 to 26 162035 10 pc(s)
Special flat fillister head
908952 100 pc(s)
screw M5x10
Special flat fillister head
909038 100 pc(s)
screw 6.0x38
Flat fillister head screw
909073 100 pc(s)
6.0x73, sealing washer
Terminal clamp 48/20 915501 100 pc(s)
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
System sections
Gasket for pressure
THERM+ FS-I
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Interior gasket 3 220320 100 m
■ Accessories
Article No. PU
Pan head tapping 100
012113
screw 5.5x40 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 33 to 34 162055 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x78 with 909078
pc(s)
sealing washer
50
Fixture spring 26/25/10 915015
pc(s)
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 10 to 14 162005 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x58 with 909058
pc(s)
sealing washer
■ Accessories
Article No. PU
System sections
THERM+ FS-I
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
■ Accessories
Article No. PU
Special flat fillister
100
head screw 6.0x78 with 909078
pc(s)
sealing washer
■ Gaskets
Article No. PU
Gasket for pressure
011805 100 m
profile 5 polygonal
Gasket for mullion 56
System sections
150140 20 m
polygonal 8° to 20°
THERM+ FS-I
Gasket for mullion 56
150145 20 m
polygonal 21° to 33°
■ Accessories
Article No. PU
Special flat fillister
100
head screw 6.0x83 with 909083
pc(s)
sealing washer
Special flat fillister
100
head screw 6.0x88 with 909088
pc(s)
sealing washer
■ Accessories
Article No. PU
Special flat fillister
100
head screw 6.0x93 with 909093
pc(s)
sealing washer
System sections
pc(s)
THERM+ FS-I
sealing ring
Special flat fillister
100
head screw 6.0x73 with 909273
or pc(s)
sealing ring
Special flat fillister
100
head screw 6.0x63 with 909663
pc(s)
sealing ring
Special flat fillister
100
head screw 6.0x73 with 909673
pc(s)
sealing ring
or
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece 100
152015
for transom 56 pc(s)
Glass carrier 25 to 26 162035 10 pc(s)
100
Cover profile fixation 80 167005
pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
System sections
THERM+ FS-I
■ Gaskets
Article No. PU
Gasket for pressure
220205 100 m
profile 2/16
■ Accessories
Article No. PU
Special flat fillister
100
head screw 6.0x73 with 909073
pc(s)
sealing washer
Special flat fillister
100
head screw 6.0x63 with 909263
System sections
pc(s)
THERM+ FS-I
sealing ring
or Special flat fillister
100
head screw 6.0x68 with 909268
pc(s)
sealing ring
Special flat fillister
100
head screw 6.0x63 with 909663
pc(s)
sealing ring
Special flat fillister
100
head screw 6.0x68 with 909668
or pc(s)
sealing ring
■ Technical information
– T129 = Vapour-tight membrane no. 951019.
■ Technical information
– T128 = Breather membrane no. 951029.
– T129 = Vapour-tight membrane no. 951019.
– T251 = Make provision for insect screen.
System sections
THERM+ FS-I
■ Technical information
– Approval required in individual cases.
– T129 = Vapour-tight membrane no. 951019.
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– Screw connection with bottom console according to
static requirements.
– T126 = Vapour-tight membrane no. 951021.
– T249 = Execution vapour-tight or as breather
membrane depending on installation-site.
– T250 = Insulation with mineral cotton when required.
– T257 = Console profile no. 146005, finished.
System sections
THERM+ FS-I
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– Screw connection with bottom console according to
static requirements.
– T126 = Vapour-tight membrane no. 951021.
– T249 = Execution vapour-tight or as breather
membrane depending on installation-site.
– T250 = Insulation with mineral cotton when required.
– T251 = Make provision for insect screen.
– T257 = Console profile no. 146005, finished.
■ Technical information
– Screw connection with ceiling plate according to
static requirements.
– Be aware of the possibility of ceiling movements!
– T126 = Vapour-tight membrane no. 951021.
– T257 = Console profile no. 146005, finished.
System sections
THERM+ FS-I
■ Technical information
– T126 = Vapour-tight membrane no. 951021.
– T257 = Console profile no. 146005, finished.
■ Technical information
– T126 = Vapour-tight membrane no. 951021.
– T251 = Make provision for insect screen.
– T252 = Breather membrane no. 951031.
– T257 = Console profile no. 146005, finished.
System sections
THERM+ FS-I
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– Pressure relief of the region behind the panel by cuttings
in the mullion gasket.
– T30 = Notching.
– T129 = Vapour-tight membrane no. 951019.
– T254 = Seal joints.
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– Pressure relief of the region behind the panel by cuttings in the mullion gasket.
– Stabilisation of the panel in the upper region when required.
– T30 = Notching.
– T129 = Vapour-tight membrane no. 951019.
– T252 = Breather membrane no. 951031.
– T253 = Insulation with non-flammable mineral-cotton.
– T254 = Seal joints.
– T257 = Console profile no. 146005, finished.
System sections
THERM+ FS-I
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– T30 = Notching.
– T129 = Vapour-tight membrane no. 951019.
– T275 = Insulation when required.
■ Technical information
– *Mask joint of mullion-transom or carry out vapour-tight.
– T30 = Notching.
– T129 = Vapour-tight membrane no. 951019.
System sections
THERM+ FS-I
■ Technical information
– T126 = Vapour-tight membrane no. 951021.
– T251 = Make provision for insect screen.
– T252 = Breather membrane no. 951031.
– T257 = Console profile no. 146005, finished.
System sections
THERM+ FS-I
■ Technical information
– T124 = Breather membrane.
– T126 = Vapour-tight membrane no. 951021.
– T251 = Make provision for insect screen.
– T252 = Breather membrane no. 951031.
– T257 = Console profile no. 146005, finished.
Add-ons
Burglar prevention
System benefits 389
Sections resistance class RC2 391
Sections resistance class RC3 403
Screw selection RC2/RC3 415
Structural Glazing
System benefits 421
Sections Structural Glazing SG2 422
Exterior sealing 425
Screw selection 428
Selection insulating block 430
Selection glass carrier 431
Suction discs 432
Indications for the execution of silicone joints 434
THERM+ FS-I
Add-ons
2017 387
388 2017
THERM+ FS-I
System benefits
THERM+ FS-I
Add-ons
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crossp. sealing plate 50 016050 10 pc(s)
THERM+ FS-I
Add-ons
Sealing piece
152010 100 pc(s)
for transom 50
Glass carrier 29 to 30 162045 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Special flat fillister
head screw 6.0x78 with 909078 100 pc(s)
sealing washer
Special flat fillister
909448 100 pc(s)
head screw 6.0x48
Protection insert TX25 915110 100 pc(s)
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crosspoint sealing
016050 10 pc(s)
plate 50
Sealing piece 100
152010
for transom 50 pc(s)
Glass carrier 29 to 30 162045 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x78 with 909078
pc(s)
sealing washer
100
Protection insert TX25 915110
pc(s)
■ Accessories
Article No. PU
Special countersunk 100
012049
sheet metal screw 5.5x24 pc(s)
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crossp. sealing plate 50 016050 10 pc(s)
THERM+ FS-I
Sealing piece
Add-ons
152070 10 pc(s)
for base transom
Glass carrier 29 to 30 162045 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister 100
909038
head screw 6.0x38 pc(s)
Special flat fillister
100
head screw 6.0x78 with 909078
pc(s)
sealing washer
100
Protection insert TX25 915110
pc(s)
■ Accessories
Article No. PU
100
Back filling 60/17 167015
pc(s)
Special flat fillister
100
head screw 6.0x78 with 909078
pc(s)
sealing washer
Special flat fillister 100
909448
head screw 6.0x48 pc(s)
100
Protection insert TX25 915110
pc(s)
THERM+ FS-I
Add-ons
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crossp. sealing plate 56 016051 10 pc(s)
THERM+ FS-I
Add-ons
Sealing piece for tran-
152015 100 pc(s)
som 56
Glass carrier 29 to 30 162045 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Special flat fillister
head screw 6.0x78 with 909078 100 pc(s)
sealing washer
Special flat fillister
909448 100 pc(s)
head screw 6.0x48
Protection insert TX25 915110 100 pc(s)
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece
152015 100 pc(s)
for transom 56
Glass carrier 29 to 30 162045 10 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Special flat fillister
head screw 6.0x78 with 909078 100 pc(s)
sealing washer
Protection insert TX25 915110 100 pc(s)
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for press. prof. 6 011076 100 m
Base gasket for transom
150120 20 m
56 with flap
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing plate
THERM+ FS-I
016051 10 pc(s)
56
Add-ons
Sealing piece
152070 10 pc(s)
for base transom
Glass carrier 29 to 30 162045 10 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Special flat fillister
head screw 6.0x78 with 909078 100 pc(s)
sealing washer
Protection insert TX25 915110 100 pc(s)
THERM+ FS-I
Add-ons
■ Gaskets
Article No. PU
Gasket for press. prof. 3 011070.LI 100 m
Gasket for press. prof. 3 011070.RE 100 m
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
THERM+ FS-I
Sealing piece
Add-ons
014035 10 pc(s)
for pressure profile 50
Crossp. sealing plate 50 016050 10 pc(s)
Sealing piece
152010 100 pc(s)
for transom 50
Glass carrier 31 to 32 162050 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Special flat fillister
head screw 6.0x78 with 909278 100 pc(s)
sealing ring
Special flat fillister
909448 100 pc(s)
head screw 6.0x48
Protection insert TX25 915110 100 pc(s)
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Sealing piece
014035 10 pc(s)
for pressure profile 50
Crossp. sealing plate 50 016050 10 pc(s)
Sealing piece
152010 100 pc(s)
for transom 50
Glass carrier 31 to 32 162050 10 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Special flat fillister
head screw 6.0x78 with 909278 100 pc(s)
sealing ring
Protection insert TX25 915110 100 pc(s)
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Sealing piece
014035 10 pc(s)
for pressure profile 50
THERM+ FS-I
Crossp. sealing plate 50 016050 10 pc(s)
Add-ons
Sealing piece
152070 10 pc(s)
for base transom
Glass carrier 31 to 32 162050 10 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Special flat fillister
head screw 6.0x78 with 909278 100 pc(s)
sealing ring
Protection insert TX25 915110 100 pc(s)
■ Accessories
Article No. PU
100
Back filling 60/17 167015
pc(s)
Special flat fillister
100
head screw 6.0x78 with 909278
pc(s)
sealing ring
Special flat fillister 100
909448
head screw 6.0x48 pc(s)
100
Protection insert TX25 915110
pc(s)
THERM+ FS-I
Add-ons
■ Gaskets
Article No. PU
Gasket for pressure
011070.LI 100 m
profile 3
Gasket for pressure
011070.RE 100 m
profile 3
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
THERM+ FS-I
sheet metal screw 5.5x24
Add-ons
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crossp. sealing plate 56 016051 10 pc(s)
Sealing pc. for transom 56 152015 100 pc(s)
Glass carrier 31 to 32 162050 10 pc(s)
Back filling 60/17 167015 100 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Special flat fillister
head screw 6.0x78 with 909278 100 pc(s)
sealing ring
Special flat fillister
909448 100 pc(s)
head screw 6.0x48
Protection insert TX25 915110 100 pc(s)
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Sealing piece
014036 10 pc(s)
for pressure profile 56
Crosspoint sealing
016051 10 pc(s)
plate 56
Sealing piece
152015 100 pc(s)
for transom 56
Glass carrier 31 to 32 162050 10 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Special flat fillister
head screw 6.0x78 with 909278 100 pc(s)
sealing ring
Protection insert TX25 915110 100 pc(s)
■ Accessories
Article No. PU
Special countersunk
012049 100 pc(s)
sheet metal screw 5.5x24
Sealing piece
014036 10 pc(s)
for pressure profile 56
THERM+ FS-I
Crossp. sealing plate 56 016051 10 pc(s)
Add-ons
Sealing piece
152070 10 pc(s)
for base transom
Glass carrier 31 to 32 162050 10 pc(s)
Special flat fillister
908952 100 pc(s)
head screw M5x10
Special flat fillister
909038 100 pc(s)
head screw 6.0x38
Special flat fillister
head screw 6.0x78 with 909278 100 pc(s)
sealing ring
167812
Protection insert TX25 915110 100 pc(s)
THERM+ FS-I
Add-ons
■ Technical Information
– The actual infill thickness should be noted.
THERM+ FS-I
Add-ons
Infill thickness Length Infill thickness Length Infill thickness Length
No. No. No.
mm mm mm mm mm mm
22 to 24 909068 68 22 909268 68 22 to 25 909268 68
25 to 29 909073 73 23 to 27 909273 73 26 to 30 909273 73
30 to 34 909078 78 28 to 32 909278 78 31 to 35 909278 78
35 to 39 909083 83 33 to 37 909283 83 36 to 40 909283 83
40 to 44 909088 88 38 to 42 909288 88 41 to 45 909288 88
45 to 49 909093 93 43 to 47 909293 93 46 to 50 909293 93
50 to 54 909098 98 48 to 52 909298 98 51 to 55 909298 98
55 to 59 909103 103 53 to 57 909303 103 56 to 60 909303 103
60 to 64 909108 108 58 to 62 909308 108 61 to 64 909308 108
63 to 64 909313 113
■ Technical Information
– The actual infill thickness should be noted.
■ Technical Information
– The actual infill thickness should be noted.
THERM+ FS-I
Add-ons
Infill RAL 9004 Stainless
Length
thickness steel
mm
mm No. No.
22 to 24 909658 909258 58
25 to 29 909663 909263 63
30 to 34 909668 909268 68
35 to 39 909673 909273 73
40 to 44 909678 909278 78
45 to 49 909683 909283 83
50 to 54 909688 909288 88
55 to 59 909693 909293 93
60 to 64 909698 909298 98
■ Technical Information
– The actual infill thickness should be noted.
■ Technical Information
– The actual infill thickness should be noted.
THERM+ FS-I
Add-ons
Infill thickness Length Infill thickness Length Infill thickness Length
No. No. No.
mm mm mm mm mm mm
22 to 23 909268 68 22 to 24 909273 73 22 909268 68
24 to 28 909273 73 25 to 29 909278 78 23 to 27 909273 73
29 to 33 909278 78 30 to 34 909283 83 28 to 32 909278 78
34 to 38 909283 83 35 to 39 909288 88 33 to 37 909283 83
39 to 43 909288 88 40 to 44 909293 93 38 to 42 909288 88
44 to 48 909293 93 45 to 49 909298 98 43 to 47 909293 93
49 to 53 909298 98 50 to 54 909303 103 48 to 52 909298 98
54 to 58 909303 103 55 to 59 909308 108 53 to 57 909303 103
59 to 63 909308 108 60 to 64 909313 113 58 to 62 909308 108
64 909313 113 63 to 64 909313 113
■ Features SG2-system
– Free choice of support construction (threaded
tubes in various material thicknesses).
– Structural profile widths 50 and 60 mm.
– Combination possible with THERM+ basic system.
– Support- and basic construction as well as the interior
gasket system are identical to the THERM+ FS-I basic system.
– Variable capabilities.
– Slim elevation widths.
– Homogeneous, building enveloping glass area.
– Maximum possible transparency.
– Many application possibilities.
– Approved curtain wall system.
– Infill thicknesses of 32 up to 64 mm.
– Simple and efficient assembly.
THERM+ FS-I
Add-ons
■ Gaskets
Article No. PU
Gasket for mullion 50 150005 20 m
Gasket for transom 50 150010 20 m
Insulating block SG
168550 50 m
25/14
■ Accessories
Article No. PU
Flat fillister head 100
012100
screw 5.5x22 pc(s)
Toggle 20/58 SG 164610 10 pc(s)
Glass carrier 29 to 30 167346 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister
100
head screw 6.0x53 with 909253
pc(s)
sealing ring
■ Gaskets
Article No. PU
Gasket for mullion 56 150105 20 m
Gasket for transom 56 150110 20 m
Insulating block SG
168550 50 m
25/14
■ Accessories
Article No. PU
Flat fillister head 100
012100
screw 5.5x22 pc(s)
Toggle 20/58 SG 164610 10 pc(s)
Glass carrier 29 to 30 167346 10 pc(s)
Special flat fillister 100
908952
head screw M5x10 pc(s)
Special flat fillister
THERM+ FS-I
100
head screw 6.0x53 with 909253
Add-ons
pc(s)
sealing ring
■ Technical information
– Approval required in individual cases.
– T129 = Vapour-tight membrane no. 951019.
■ Technical information
– T30 A = Notching toggle
– T30 B = Notching glass carrier.
– T31 = Width of glass joint 24 mm.
– T142 = Screwing in of the SG toggle
with tool no. 170750.
THERM+ FS-I
Add-ons
■ Technical information
– RB = Grid width
RH = Grid height.
– T58 = Length of the gasket for transom
= RB - 28 + 0.5% add-on.
– T66 = Length of the base profile = RB - 56.
– T67 = Glass dimension = RB or RH - 24.
– T202 = Length of structural profile = RB - 50.
■ Technical information
– RB = Grid width
RH = Grid height.
– T65 = Length of the gasket for transom
= RB - 34 + 0.5%.
– T67 = Glass dimension = RB or RH - 24.
– T115 = Length of base profile = RB - 66.
– T278 = Length of structural profile = RB - 60.
THERM+ FS-I
Add-ons
■ Technical information
– Screw selection tables apply only for a cavity
of 18 mm between the glass panes (glass edge)
and a centric position of the aluminium U profile
no. 034052 in the glass edge.
– The actual infill thickness should be noted.
– T262 = Nominal dimension
(= inner pane thickness + 5 mm).
Nominal
Length
dimension No.
mm
mm
11 909253 53
12 to 16 909258 58
17 to 21 909263 63
22 to 26 909268 68
27 to 31 909273 73
32 to 36 909278 78
37 to 41 909283 83
41 to 43 909288 88
■ Technical information
– The actual infill thickness should be noted.
– For suction disc no. 163809, – For suction disc no. 163809,
163811, 163813. 163811, 163813.
THERM+ FS-I
Add-ons
Infill RAL 9004 Stainless Infill RAL 9004 Stainless
Length Length
thickness steel thickness steel
mm mm
mm No. No. mm No. No.
20 909663 909263 63 10 909663 909263 63
21 to 25 909668 909268 68 11 to 15 909668 909268 68
26 to 30 909673 909273 73 16 to 20 909673 909273 73
31 to 35 909678 909278 78
36 to 40 909683 909283 83
41 to 45 909688 909288 88
46 to 50 909693 909293 93
51 to 55 909698 909298 98
56 to 60 909703 909303 103
61 to 64 909708 909308 108
■ Technical information
– The outer pane must be in tempered glass
with min. 8 mm thickness.
– A silicone joint width of 8 to 9 mm results by using
this table, exept for an infill thickness of 25 mm.
In that case the silicone joint width is 10 mm.
– From an infill thickness of 32 mm with aluminium
U profile no. 034052 possible.
Infill thickness
No.
mm
23 to 25 168541
26 to 27 168544
28 to 29 168546
30 to 31 168548
32 to 33 168550
34 to 35 168552
36 to 37 168554
38 to 39 168556
40 to 41 168558
42 to 43 168560
44 to 45 168562
46 to 47 168564
48 to 49 168566
50 to 51 168568
52 to 53 168570
54 to 55 168572
56 to 57 168564 + 168546
58 to 59 2x 168556
60 to 61 168568 + 168546
62 to 63 2x 168558
64 168572 + 168546
■ Technical information
– The outer pane must be in tempered glass
with min. 8 mm thickness.
– Bearing surface of the outer pane on the glass carrier:
min. 50 % of the glass thickness + 1 mm.
– From an infill thickness of 32 mm with ETAG
U profile no. 034052 possible.
– Screw connection with
- 3 countersunk sheet metal screws no. 012028
each for no. 167321 to 167341.
- 3 flat fillister head screws no. 012100
each for no. 167346 to 167926.
THERM+ FS-I
Add-ons
Infill
thickness No. Article PU
mm
22 to 23 167321 Glass carrier 19 to 20 10 pc(s)
24 to 25 167326 Glass carrier 21 to 22 10 pc(s)
26 to 27 167331 Glass carrier 23 to 24 10 pc(s)
28 to 29 167336 Glass carrier 25 to 26 10 pc(s)
30 to 31 167341 Glass carrier 27 to 28 10 pc(s)
32 to 33 167346 Glass carrier 29 to 30 10 pc(s)
34 to 35 167351 Glass carrier 31 to 32 10 pc(s)
36 to 37 167356 Glass carrier 33 to 34 10 pc(s)
38 to 39 167361 Glass carrier 35 to 36 10 pc(s)
40 to 41 167366 Glass carrier 37 to 38 10 pc(s)
42 to 43 167371 Glass carrier 39 to 40 10 pc(s)
44 to 45 167376 Glass carrier 41 to 42 10 pc(s)
46 to 47 167381 Glass carrier 43 to 44 10 pc(s)
48 to 49 167386 Glass carrier 45 to 46 10 pc(s)
50 to 51 167391 Glass carrier 47 to 48 10 pc(s)
52 to 53 167396 Glass carrier 49 to 50 10 pc(s)
54 to 55 167401 Glass carrier 51 to 52 10 pc(s)
56 to 57 167906 Glass carrier 53 to 54 10 pc(s)
58 to 59 167911 Glass carrier 55 to 56 10 pc(s)
60 to 61 167916 Glass carrier 57 to 58 10 pc(s)
62 to 63 167921 Glass carrier 59 to 60 10 pc(s)
64 167926 Glass carrier 61 to 62 10 pc(s)
■ Technical information
– For additional mechanical saving for all
heights larger than 8 m.
Suction disc set 75 Suction disc set 50/90 Suction disc set 56/90
No. 163809 No. 163811 No. 163813
■ Technical information
– T164 = Built-in conditions.
– T170 = Assembly suction disc.
– T171 = Suction disc variants.
– T172 = Suction disc set.
– T201 = Assembly aid no. 015230.
THERM+ FS-I
Add-ons
SG-curtain walls with silicone joint SG-curtain walls with silicone joint on two
on four sides sides and pressure profile on two sides
434 2017
Content
Assembly options
Connector technology
Screw connection with steel connector SC 436
Screw connection with conductor connector SCL 437
Glazing/Sealing technology
Load transmission 438
Overview and selection of glass carriers 447
Glass weights/eccentricity 448
Interior sealing system 456
Exterior sealing system 469
Screw selection 478
Accessories
Fixation for sun protection systems 489
Installation scaffolding fixation 514
Installation fixture unit 515
Connection profiles 519
Suction discs 537
Belay sheet 538
Assembly options
THERM+ FS-I
2017 435
THERM+ FS-I
Connector technology
■ Technical information
– T82 = Mullion element.
– T86 = Transom element.
– T265 = Special flat fillister head screw
M6.0x15 no. 908953.
– T266 = Special threaded pin.
– T267 = Special flat fillister head screw
5.0x30 no. 908030.
– T268 = Fixing element 61.
– T269 = Reinforcing plate.
■ Technical information
– T265 = Special flat fillister head screw
M6x15 no. 908953.
– T270 = Steel connector SCL.
– T271 = Special flat fillister head screw
M6x46 no. 908954.
Assembly options
THERM+ FS-I
– T272 = Fixing part.
– T273 = Special flat fillister head screw
5.0x15 no. 908046.
■ Technical information
– Glass loads see chapter Glass weights.
– Selection of the glass carriers and the suitable screws see Overview and selection glass carriers.
– For integration elements the
- Base profile glass carrier L IE no. 167700 (50) or 167702 (56) are required.
- Base profile glass carrier L and base profile adapter (see table) do not apply in this case.
– T155 = Transom gasket.
– T242 = Glass carrier.
– T285 = Tapping screw.
– T286 = Base profile adapter.
– T287 = Threaded tube.
– T288 = Synthetic base profile.
– T289 = Base profile glass carrier.
– T290 = Special flat fillister head screw.
– T291 = Special flat fillister head screw no. 909038.
– T292 = Special flat fillister head screw no. 908952.
■ Technical information
– Glass loads see chapter Glass weights.
– Selection of the glass carriers and the suitable screws see Overview and selection glass carriers.
– For integration elements the
- Base profile glass carrier L IE no. 167700 (50) or 167702 (56) are required.
- Base profile glass carrier L and base profile adapter (see table) do not apply in this case.
– T155 = Transom gasket.
– T242 = Glass carrier.
– T285 = Tapping screw.
– T286 = Base profile adapter.
– T287 = Threaded tube.
Assembly options
– T288 = Synthetic base profile.
THERM+ FS-I
– T289 = Base profile glass carrier.
– T291 = Special flat fillister head screw no. 909038.
– T292 = Special flat fillister head screw no. 908952.
– T293 = Special flat fillister head screw no. 908037.
■ Technical information
– Glass loads see chapter Glass weights.
– Selection of the glass carriers and the suitable screws
see Overview and selection glass carriers.
– Applicable from a transom depth of 90 mm and a wall thickness of 3 mm in the transom.
– T155 = Transom gasket.
– T242 = Glass carrier.
– T285 = Tapping screw.
– T287 = Threaded tube.
– T288 = Synthetic base profile.
– T289 = Base profile glass carrier.
– T291 = Special flat fillister head screw no. 909038.
– T292 = Special flat fillister head screw no. 908952.
– T294 = Special flat fillister head
screw no. 908038.
■ Technical information
– Glass loads see chapter Glass weights.
– Selection of the cross glass carriers and the suitable screws
see Assembly and installation of cross glass carriers.
– Applicable from a transom depth of 90 mm.
– T154 = Mullion gasket.
– T155 = Transom gasket.
– T287 = Threaded tube.
– T288 = Synthetic base profile.
– T289 = Base profile glass carrier.
Assembly options
– T291 = Special flat fillister head screw 909038.
THERM+ FS-I
– T292 = Special flat fillister head screw
no. 908952.
– T294 = Special flat fillister head screw
no. 908038.
– T295 = Flat fillister head screw
no. 012101.
– T296 = Special flat fillister head screw
no. 909468.
– T297 = Cross glass carrier set.
– T298 = Base profile mullion.
■ Technical information
– Glass loads see chapter Glass weights.
– Selection of the cross glass carriers and the suitable screws see
Assembly and installation of cross glass carriers.
– Applicable from a transom depth of 90 mm.
– T154 = Mullion gasket.
– T155 = Transom gasket.
– T287 = Threaded tube.
– T288 = Synthetic base profile.
– T289 = Base profile glass carrier.
– T291 = Special flat fillister head screw 909038.
– T292 = Special flat fillister head screw
no. 908952.
– T295 = Flat fillister head screw
no. 012101.
– T296 = Special flat fillister head screw
no. 909468.
– T297 = Cross glass carrier set.
– T298 = Base profile mullion.
T145
Assembly options
THERM+ FS-I
■ Technical information
– T82 = Mullion element.
– T86 = Transom element.
Selection of screws
Alternative: individual order (number of screws per cross point glass carrier)
Screw set Connection Screw connection in transom
no. Screw connection
mullion with transom
or in mullion Double-sided Unilateral
piece
No. No. No. No.
163793
2x 012101 3x 909468 6x 012101 3x 012101
Content per set: screws for 2 cross point glass carriers (1 set per transom needed).
Assembly cross point glass carrier set Assembly cross point glass carrier set
– Assembly double-sided (e. g. in cross point). – Unilateral assembly (e. g. in the edge region).
– Screws have to be ordered separately (see table). The transom piece has to be shortened accordingly.
– Screws have to be ordered separately (see table).
■ Technical information
– Glass loads see chapter Glass weights.
– Selection of the glass carriers and the suitable screws
see Overview and selection glass carriers.
– T155 = Transom gasket.
– T242 = Glass carrier.
– T286 = Base profile adapter.
– T287 = Threaded tube.
– T288 = Synthetic base profile.
– T289 = Base profile glass carrier.
Assembly options
– T291 = Special flat fillister head screw no. 909038.
THERM+ FS-I
– T292 = Special flat fillister head screw no. 908952.
– T294 = Special flat fillister head screw no. 908038.
– T299 = Special flat fillister head screw
no. 908308.
■ Technical information
– Glass loads see chapter Glass weights.
– Selection of the glass carriers and the suitable screws
see Overview and selection glass carriers.
– T155 = Transom gasket.
– T242 = Glass carrier.
– T286 = Base profile adapter.
– T287 = Threaded tube.
– T288 = Synthetic base profile.
– T289 = Base profile glass carrier.
– T291 = Special flat fillister head screw no. 909038.
– T292 = Special flat fillister head screw no. 908952.
– T293 = Special flat fillister head screw no. 908037.
– T299 = Special flat fillister head screw no. 908308.
■ Technical information
– Glass loads see chapter Glass weights.
Assembly options
– Requirement of screws per glass carrier:
THERM+ FS-I
- Synthetic glass carrier:
Infill thicknesses from 12 to 64 mm:
Fixation with 3x screw no. 012049 each.
- Aluminium glass carrier:
Infill thickness up to 28 mm fixed by 3x screw no. 012028 each.
Infill thickness from 29 mm fixed by 3x screw no. 012100 each.
■ Technical information
– Glass loads see chapter Glass weights.
– Requirement of screws per glass carrier:
- Aluminium glass carrier:
Fixation with 3x screw no. 908308 each.
■ Technical information
– Dimension c (interior compensation of the glass thickness) must not exceed
14 mm. Higher dimensions are only permitted after consultation with RAICO.
– Calculation tables regarding the determination of the eccentricity
you will find in the Download area on www.raico.de.
– IBP = Interspace between panes.
– All dimensions in mm.
Assembly options
≥ 90 x 4 500 479 367 290 235 196 166 8.5 kN
THERM+ FS-I
≥ 2 mm
≥ 120 x 2 500 479 367 290 235 196 166 8.0 kN
≥ 120 x 3 500 479 367 290 235 196 166 9.5 kN
≥ 120 x 4 500 479 367 290 235 196 166 9.0 kN
Assembly options
≥ 120 x 4 700 700 700 637 530 449 386 7.5 kN
THERM+ FS-I
Fitness for use – tipping over 2.0 mm
■ Technical information
– The tests and evaluations for determining the glass loads were carried
Screw channel out according to EN 16758. A max. tipping over of 1 mm is recommended.
closed – The safety coefficients on the point of application side are extracted
from the National Annexes (Germany) of the EUROCODES.
– A combination of glass load and horizontal load is calculated by linear
interaction.
– The indicated wind loads refer to the maximum glass weight
of 750 kg or 1000 kg.
– Deviating constructions available on request.
– In case of an additional load please consult the RAICO customer service.
– The glass weights refer to one field. All variants can be applied similarly
to commercial steel tubes for the various fixing options of the base profiles
(except the welded screw channel). In case of the demand for a cross
glass carrier with two fields, please consult the RAICO customer service.
– Intermediate figures can be interpolated.
– *Minimum face width 50 mm.
– ** Ɣq = 1.5 considered.
Assembly options
≥ 90 x 4 500 471 360 284 231 192 163 21.5 kN
THERM+ FS-I
≥ 2 mm
≥ 120 x 2 500 471 360 284 231 192 163 20.5 kN
≥ 120 x 3 500 471 360 284 231 192 163 23.5 kN
≥ 120 x 4 500 471 360 284 231 192 163 23.5 kN
■ Technical information
– The tests and evaluations for determining the glass loads were carried
out according to EN 16758. A max. tipping over of 1 mm is recommended. Screw channel
– The safety coefficients on the point of application side are extracted closed
from the National Annexes (Germany) of the EUROCODES.
– A combination of glass load and horizontal load is calculated by linear
interaction.
– The indicated wind loads refer to the maximum glass weight
of 750 kg or 1000 kg.
– Deviating constructions available on request.
– In case of an additional load please consult the RAICO customer service.
– The glass weights refer to one field. All variants can be applied similarly to
commercial steel tubes for the various fixing options of the base profiles
(except the welded screw channel). In case of the demand for a cross glass
carrier with two fields, please consult the RAICO customer service.
– Intermediate figures can be interpolated.
– *Minimum face width 50 mm.
– ** Ɣq = 1.5 considered.
Assembly options
≥ 2mm ≥ 120 x 2 750 750 750 750 750 750 750 23.5 kN
THERM+ FS-I
≥ 120 x 3 1.000 1.000 1.000 1.000 1.000 1.000 1.000 21.5 kN
≥ 120 x 4 1.000 1.000 1.000 1.000 1.000 1.000 1.000 21.0 kN
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– The use of gaskets type “S” is recommended.
Alternatively, the application of the gaskets type “L” is possible.
– Applicable gaskets
- Gasket for mullion with notching by special tool
(see Processing)
No. 150005 Gasket for mullion 50
No. 150105 Gasket for mullion 56
No. 150040 to 150050 Gasket for mullion 50 polygon
No. 150140 to 150150 Gasket for mullion 56 polygon
- PU = 20 m.
– - Gasket for transom with notching by special tool
(see Processing)
No. 150010 Gasket for transom 50
No. 150110 Gasket for transom 56
- PU = 20 m.
Sealing piece for transom gasket
No. 152010 Transom sealing piece 50
No. 152015 Transom sealing piece 56
- PU = 100 pc(s)
- Assembly without sealing material.
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Tightening torque for no. 167007:
- approx. 1.5 Nm in the base profile adapter.
- approx. 2.5 Nm in the base profile for glass carrier with open screw channel.
- approx. 4 Nm in the base profile for glass carrier SC H.
– The use of gaskets type “S” is recommended.
Alternatively, the application of the gaskets type “L” is possible.
– Applicable gaskets
- Gasket for mullion with notching by special tool
(see Processing)
No. 150005 Gasket for mullion 50
No. 150105 Gasket for mullion 56
No. 150040 to 150050 Gasket for mullion 50 polygon
No. 150140 to 150150 Gasket for mullion 56 polygon
- PU = 20 m.
- Gasket for transom with notching by special tool
(see Processing)
No. 150015 Gasket for transom 50, flap
No. 150115 Gasket for transom 56, flap
- PU = 20 m.
Sealing piece for transom gasket
No. 152010 Transom sealing piece 50
No. 152015 Transom sealing piece 56
- PU = 100 pc(s)
- Assembly without sealing material.
– T196 = Belay sheet no. 167007.
– T286 = Base profile adapter.
Assembly options
THERM+ FS-I
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Tightening torque for no. 167007:
- approx. 1.5 Nm in the base profile adapter.
- approx. 2.5 Nm in the base profile for glass carrier with open screw channel.
- approx. 4 Nm in the base profile for glass carrier SC H.
– The use of gaskets type “S” is recommended.
Alternatively, the application of the gaskets type “L” is possible.
– Applicable gaskets
- Base gasket with notching by special tool
(see Processing)
No. 150020 Base gasket 50, flap
No. 150120 Base gasket 56, flap
- PU = 20 m.
Sealing piece for base gasket
No. 152070 Base transom sealing piece,
applicable for all system widths.
- PU = 10 pc(s)
- Assembly with sealing material D2, no. 952015
or with special silicone B1, no. 952020.
– T196 = Belay sheet no. 167007.
– T199 = Sealing piece.
– T286 = Base profile adapter.
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– The use of gaskets type “S” is recommended.
Alternatively, the application of the gaskets type “L” is possible.
– Applicable gaskets (PU = 20 m)
- Base gasket with notching by special tool
(see Processing)
No. 150020 Base gasket 50, flap
No. 150120 Base gasket 56, flap
- PU = 20 m.
- Assembly with sealing material D2, no. 952015
or with special silicone B1, no. 952020.
Assembly options
THERM+ FS-I
– T38 = Level 2.
– T39 = Level 3.
– T40 = Level 1.
– T151 = Interior gasket E3. Interior gaskets for drainage level 2
Article No. PU
Interior gasket 50 E3 150008 20 m
Interior gasket 56 E3 150108 20 m
Article No. PU
Transom sealing piece 50 152010 100 pc(s)
Transom sealing piece 56 152015 100 pc(s)
Article No. PU
Transom sealing piece 50 E2 152009 100 pc(s)
Transom sealing piece 56 E2 152014 100 pc(s)
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– The use of gaskets type “S” is recommended.
Alternatively, the application of the gaskets type “L” is possible.
– Applicable gaskets
- Gasket for transom with notching by special tool
(see Processing)
No. 150010 Gasket for transom 50
No. 150110 Gasket for transom 56
- PU = 20 m.
– - Gasket for transom with notching by special tool
(see Processing)
No. 150013 Interior gasket 50 E2
No. 150113 Interior gasket 56 E2
- PU = 20 m.
Sealing piece for transom gasket
No. 152010 Transom sealing piece 50
No. 152015 Transom sealing piece 56
- PU = 100 pc(s)
- Assembly without sealing material.
– T38 = Level 2.
– T40 = Level 1.
Assembly options
THERM+ FS-I
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– The use of gaskets type “S” is recommended.
Alternatively, the application of the gaskets type “L” is possible.
– Applicable gaskets
- Gasket for transom with notching by special tool
(see Processing)
No. 150008 Interior gasket 50 E3
No. 150108 Interior gasket 56 E3
- PU = 20 m.
– - Gasket for transom with notching by special tool
(see Processing)
No. 150013 Interior gasket 50 E2
No. 150113 Interior gasket 56 E2
- PU = 20 m.
Sealing piece for transom gasket
No. 152009 Transom sealing piece 50 E2
No. 152014 Transom sealing piece 56 E2
- PU = 100 pc(s)
- Assembly without sealing material.
– T38 = Level 2.
– T39 = Level 3.
■ Technical information
– The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Tightening torque for no. 167007:
- approx. 1.5 Nm in the base profile adapter.
- approx. 2.5 Nm in the base profile for glass carrier with open screw channel.
- approx. 4 Nm in the base profile for glass carrier SC H.
– The use of gaskets type “S” is recommended.
Alternatively, the application of the gaskets type “L” is possible.
– Applicable gaskets
– - Gasket for mullion with notching by special tool
(see Processing)
No. 150008 Interior gasket 50 E3
No. 150108 Interior gasket 56 E3
- PU = 20 m.
- Gasket for transom with notching by special tool
(see Processing)
No. 150018 Interior gasket 50 E2 flap
No. 150118 Interior gasket 56 E2 flap
- PU = 20 m.
Sealing piece for transom gasket
No. 152009 Transom sealing piece 50 E2
No. 152014 Transom sealing piece 56 E2
- PU = 100 pc(s)
- Assembly without sealing material.
– T38 = Level 2.
– T39 = Level 3.
– T196 = Belay sheet no. 167007.
– T286 = Base profile adapter.
Assembly options
THERM+ FS-I
■ Technical information
The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Applicable gaskets
- Gasket for transom with notching by special tool
(see Processing)
No. 150461 Transom gasket 50/26
No. 150462 Interior gasket 50/26 E3
- PU = 20 m.
Sealing piece for transom gasket
No. 152007 Transom sealing piece 50/26 E1
No. 152011 Transom sealing piece 50/26 E2
- PU = 100 pc(s)
- Assembly without sealing material.
– T188 = Transom sealing piece.
■ Technical information
The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Applicable gaskets
- Gasket for transom with notching by special tool
(see Processing)
No. 150461 Transom gasket 50/26
No. 150463 Interior gasket 50/26 E2
- PU = 20 m.
Sealing piece for transom gasket
No. 152007 Transom sealing piece 50/26 E1
- PU = 100 pc(s)
- Assembly without sealing material.
– T38 = Level 2.
– T40 = Level 1.
Assembly options
THERM+ FS-I
■ Technical information
The steel construction must be flush on the glazing side.
Max. misalignment between mullion and transom = ± 0.5 mm.
– Applicable gaskets
- Gasket for transom with notching by special tool
(see Processing)
No. 150462 Interior gasket 50/26 E3
No. 150463 Interior gasket 50/26 E2
- PU = 20 m.
Sealing piece for transom gasket
No. 152011 Transom sealing piece 50/26 E2
- PU = 100 pc(s)
- Assembly without sealing material.
– T38 = Level 2.
– T39 = Level 3.
■ Technical information
A
– The joint areas must be sealed carefully with sealing material
D2 no. 952015 (for silicone gaskets with special silicone B1
no. 952020) after thorough cleansing with cleaner 450
no. 952000. The stainless steel sealing pieces must be fixed
with two screws no. 902805 each.
– For more information see Processing.
– T199 = Sealing piece.
Straight extension
A
System Stainless steel sealing piece
width for mullion for transom for level E3
mm PU
no. no. no.
50 167105 167131 167103 10 pc(s)
B 56 167115 – – 10 pc(s)
Assembly options
THERM+ FS-I
FS-I KS-0006, FS-I KS-0007, FS-I KS-0008; FS-I KS-0018 2017 467
THERM+ FS-I
Glazing/Sealing technology
43 to 44 8 12 8 10
45 to 46 6 10 6 8
47 to 48 4 8 4 6
49 to 50 2 6 2 4
51 to 52 0 4 0 2
to
Assembly options
THERM+ FS-I
Assembly options
THERM+ FS-I
■ Technical information
– All insulating blocks must be notched with
a special tool at the end of the transom gasket
(A) for assembling the sealing piece for
pressure profile (see Processing).
– The version with insulating blocks 21 and
P must be notched (B) additionally with a
special tool in the area of the glass support
(see Processing).
– PU of the insulating blocks = 50 m.
– T50 = Notching A.
– T51 = Notching B.
– T162 = Cross point sealing plate.
– T163 = Sealing piece for pressure profile.
■ Technical information Selection of interior joint plate and profile joint sealing plate
– Do not joint the pressure profile at the cross point. Sealing piece
Interior Profile joint
– Length exterior gasket = length pressure profile + 0.5 %. Cover profile for pressure
joint plate sealing plate
– For more information see Processing. no. profile
no. no.
no.
– T160 = Joint in the intermediate area.
013003 (50x15) 014035 167230 016070
– T161 = Joint at the cross point.
013210 (50x20) 014035 167232 016070
– T163 = Sealing piece for pressure profile.
013201 (50x25) 014035 167230 016070
– T174 = Pressure profile.
– T175 = Cover profile. 013005 (50x25) 014035 167230 016070
Assembly options
THERM+ FS-I
Assembly options
THERM+ FS-I
Flat pressure profile
■ Technical information
– RB = Grid width
RH = Grid height.
– The different length extensions of the
materials have to be observed.
– T53 = Length flatpressure profile = RB - 51.
– T54 = Length pressure profile with visible
screw connection = RB - 51.
– T55 = Length cover profile clipped = RB - 51.
– T56 = Length pressure profile = RB - 55.
– T57 = Glass dimensions = RB or RH - 26.
– T58 = Length transom gasket
= RB - 28 + 0.5% add-on.
– T66 = Length of the base profile = RB - 56.
– T202 = Length of the structural profile = RB - 50.
– T274 = Glass dimension passive house
= FW or FH - 24.
■ Technical information
– RB = Grid width
RH = Grid height.
– The different length extensions of the
materials have to be observed.
– T60 = Length flat pressure profile = RB - 57.
– T61 = Length pressure profile with visible
screw connection = RB - 57.
– T62 = Length cover profile clipped = RB - 57.
– T63 = Length pressure profile = RB - 61.
– T64 = Glass dimensions = RB or RH - 30.
– T65 = Length transom gasket
= RB - 34 + 0.5 % add-on.
– T115 = Length of the base profile = SW - 66.
– T280 = Glass dimension passive house
= FW or FH - 30.
Assembly options
THERM+ FS-I
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11
and 13 extended screws must be used.
– The actual infill thickness should be noted.
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11
and 13 extended screws must be used.
– The actual infill thickness should be noted.
Assembly options
THERM+ FS-I
Infill Infill
RAL 9004 Stainl. Steel Length RAL 9004 Stainl. Steel Length
thickness thickness
No. No. mm No. No. mm
mm mm
12 909663 909263 63 12 to 15 909663 909263 63
13 to 17 909668 909268 68 16 to 20 909668 909268 68
18 to 22 909673 909273 73 21 to 25 909673 909273 73
23 to 27 909678 909278 78 26 to 30 909678 909278 78
28 to 32 909683 909283 83 31 to 35 909683 909283 83
33 to 37 909688 909288 88 36 to 40 909688 909288 88
38 to 42 909693 909293 93 41 to 45 909693 909293 93
43 to 47 909698 909298 98 46 to 50 909698 909298 98
48 to 52 909703 909303 103 51 to 55 909703 909303 103
53 to 57 909708 909308 108 56 to 60 909708 909308 108
58 to 62 – 909313 113 61 to 64 – 909313 113
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11
and 13 extended screws must be used.
– The actual infill thickness should be noted.
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11
and 13 extended screws must be used.
– The actual infill thickness should be noted.
Assembly options
THERM+ FS-I
Infill Infill Length Infill Length
Length
thickness No. thickness No. mm thickness No. mm
mm
mm mm mm
10 to 13 909058 58 10 to 11 909258 58 10 to 14 909258 58
14 to 18 909063 63 12 to 16 909263 63 15 to 19 909263 63
19 to 23 909068 68 17 to 21 909268 68 20 to 24 909268 68
24 to 28 909073 73 22 to 26 909273 73 25 to 29 909273 73
29 to 33 909078 78 27 to 31 909278 78 30 to 34 909278 78
34 to 38 909083 83 32 to 36 909283 83 35 to 39 909283 83
39 to 43 909088 88 37 to 41 909288 88 40 to 44 909288 88
44 to 48 909093 93 42 to 46 909293 93 45 to 49 909293 93
49 to 53 909098 98 47 to 51 909298 98 50 to 54 909298 98
54 to 58 909103 103 52 to 56 909303 103 55 to 59 909303 103
59 to 63 909108 108 57 to 61 909308 108 60 to 64 909308 108
64 909113 113 62 to 64 909313 113
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11
and 13 extended screws must be used.
– The actual infill thickness should be noted.
Infill Infill
RAL 9004 Stainl. Steel Length RAL 9004 Stainl. Steel Length
thickness thickness
No. No. mm No. No. mm
mm mm
10 to 11 909663 909263 63 10 to 14 909663 909263 63
12 to 16 909668 909268 68 15 to 19 909668 909268 68
17 to 21 909673 909273 73 20 to 24 909673 909273 73
22 to 26 909678 909278 78 25 to 29 909678 909278 78
27 to 31 909683 909283 83 30 to 34 909683 909283 83
32 to 36 909688 909288 88 35 to 39 909688 909288 88
37 to 41 909693 909293 93 40 to 44 909693 909293 93
42 to 46 909698 909298 98 45 to 49 909698 909298 98
47 to 51 909703 909303 103 50 to 54 909703 909303 103
52 to 56 909708 909308 108 55 to 59 909708 909308 108
57 to 61 – 909313 113 60 to 64 – 909313 113
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11
and 13 extended screws must be used.
– The actual infill thickness should be noted.
Assembly options
THERM+ FS-I
Infill Length Infill Length
thickness No. mm thickness No. mm
mm mm
10 to 14 909068 68 10 to 12 909063 63
15 to 19 909073 73 13 to 17 909068 68
20 to 24 909078 78 18 to 22 909073 73
25 to 29 909083 83 23 to 27 909078 78
30 to 34 909088 88 28 to 32 909083 83
35 to 39 909093 93 33 to 37 909088 88
40 to 44 909098 98 38 to 42 909093 93
45 to 49 909103 103 43 to 47 909098 98
50 to 54 909108 108 48 to 52 909103 103
55 to 59 909113 113 53 to 57 909108 108
58 to 62 909113 113
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11
and 13 extended screws must be used.
– The actual infill thickness should be noted.
– For flat pressure profile – For flat pressure profile – For flat pressure profile
no. 013300, 013310, 013313. no. 013300, 013310, 013313. no. 013300, 013310, 013313.
2
2
2
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11
and 13 extended screws must be used.
– The actual infill thickness should be noted.
Assembly options
THERM+ FS-I
Infill Infill Length Infill Length
Length
thickness No. thickness No. mm thickness No. mm
mm
mm mm mm
4 909058 58 4 to 7 909263 63 4 to 5 909258 58
5 to 9 909063 63 8 to 12 909268 68 6 to 10 909263 63
10 to 14 909068 68 13 to 17 909273 73 11 to 15 909268 68
15 to 19 909073 73 18 to 20 909278 78 16 to 20 909273 73
20 909078 78
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11
and 13 extended screws must be used.
– The actual infill thickness should be noted.
Infill Infill
RAL 9004 Stainl. Steel Length RAL 9004 Stainl. Steel Length
thickness thickness
No. No. mm No. No. mm
mm mm
4 to 7 909668 909268 68 4 to 5 909663 909263 63
8 to 12 909673 909273 73 6 to 10 909668 909268 68
13 to 17 909678 909278 78 11 to 15 909673 909273 73
18 to 20 909683 909283 83 16 to 20 909678 909278 78
■ Technical information
– For the application of the pressure profile gaskets 4, 6, 7, 8, 9, 11
and 13 extended screws must be used.
– The actual infill thickness should be noted.
Assembly options
THERM+ FS-I
Infill Length Infill Length
thickness No. mm thickness No. mm
mm mm
4 to 5 909068 68 4 to 8 909068 68
6 to 10 909073 73 9 to 13 909073 73
11 to 15 909078 78 14 to 18 909078 78
16 to 20 909083 83 19 to 20 909083 83
Assembly options
– T224 = See table.
THERM+ FS-I
to
Screw distance 90 mm
Vertical for ce
in use Fv [kN]
■ Technical information 1.30
1.30 1.30
1.25 1.25
1.20 1.20
1.15 1.15
1.10 1.10
1.05 1.05
1.00 1.00
0.95 0.95
0.90 0.90
0.85 0.85
0.80 0.80
0.75 0.75
0.70 0.70
0.65 0.65
0.60 0.60
0.55 0.55
0.50 0.50
0.45 0.45
0.40 0.40
0.35 0.35
0.30 0.30
Length of Length of
socket [mm] socket [mm]
1.30 1.30
1.25 1.25
1.20 1.20
1.15 1.15
1.10 1.10
1.05 1.05
1.00 1.00
0.95 0.95
0.90 0.90
0.85 0.85
0.80 0.80
0.75 0.75
0.70 0.70
0.65 0.65
0.60 0.60
0.55 0.55
0.50 0.50
0.45 0.45
0.40 0.40
0.35 0.35
0.30 0.30
Length of Length of
socket [mm] socket [mm]
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
– Cover profiles:
No. 141101 (50 mm)
No. 141301 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169946 169905
21 to 22 169946 169904
23 to 24 169950 169905
25 to 26 169950 169904
27 to 28 169954 169905
29 to 30 169954 169904
31 to 32 169958 169905
33 to 34 169958 169904
35 to 36 169962 169905
37 to 38 169962 169904
39 to 40 169966 169905
41 to 42 169966 169904
43 to 44 169970 169905
45 to 46 169970 169904
47 to 48 169974 169905
49 to 50 169974 169904
Assembly options
51 to 52 169978 169905
THERM+ FS-I
53 to 54 169978 169904
55 to 56 169982 169905
57 to 58 169982 169904
59 to 60 169986 169905
61 to 62 169986 169904
63 to 64 169990 169905
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
– Cover profiles:
No. 141101 (50 mm)
No. 141103 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169946 169904
22 to 23 169950 169905
24 to 25 169950 169904
26 to 27 169954 169905
28 to 29 169954 169904
30 to 31 169958 169905
32 to 33 169958 169904
34 to 35 169962 169905
36 to 37 169962 169904
38 to 39 169966 169905
40 to 41 169966 169904
42 to 43 169970 169905
44 to 45 169970 169904
46 to 47 169974 169905
48 to 49 169974 169904
50 to 51 169978 169905
52 to 53 169978 169904
54 to 55 169982 169905
56 to 57 169982 169904
58 to 59 169986 169905
60 to 61 169986 169904
62 to 63 169990 169905
64 169990 169904
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
– Cover profiles:
No. 013003 (50 mm)
No. 013023 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169946 169905
21 169946 169904
22 169950 169906
23 to 24 169950 169905
25 169950 169904
26 169954 169906
27 to 28 169954 169905
29 169954 169904
30 169958 169906
31 to 32 169958 169905
33 169958 169904
34 169962 169906
35 to 36 169962 169905
37 169962 169904
38 169966 169906
39 to 40 169966 169905
Assembly options
41 169966 169904
THERM+ FS-I
42 169970 169906
43 to 44 169970 169905
45 169970 169904
46 169974 169906
47 to 48 169974 169905
49 169974 169904
50 169978 169906
51 to 52 169978 169905
53 169978 169904
54 169982 169906
55 to 56 169982 169905
57 169982 169904
58 169986 169906
59 to 60 169986 169905
61 169986 169904
62 169990 169906
63 to 64 169990 169905
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
– Cover profiles:
No. 013003 (50 mm)
No. 013023 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169946 169904
21 169950 169906
22 to 23 169950 169905
24 169950 169904
25 169954 169906
26 to 27 169954 169905
28 169954 169904
29 169958 169906
30 to 31 169958 169905
32 169958 169904
33 169962 169906
34 to 35 169962 169905
36 169962 169904
37 169966 169906
38 to 39 169966 169905
40 169966 169904
41 169970 169906
42 to 43 169970 169905
44 169970 169904
45 169974 169906
46 to 47 169974 169905
48 169974 169904
49 169978 169906
50 to 51 169978 169905
52 169978 169904
53 169982 169906
54 to 55 169982 169905
56 169982 169904
57 169986 169906
58 to 59 169986 169905
60 169986 169904
61 169990 169906
62 to 63 169990 169905
64 169990 169904
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
– Cover profiles:
No. 013210 (50 mm)
No. 013410 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169950 169907
21 to 22 169954 169908
23 to 24 169954 169907
25 to 26 169958 169908
27 to 28 169958 169907
29 to 30 169962 169908
31 to 32 169962 169907
33 to 34 169966 169908
35 to 36 169966 169907
37 to 38 169970 169908
39 to 40 169970 169907
41 to 42 169974 169908
43 to 44 169974 169907
45 to 46 169978 169908
47 to 48 169978 169907
49 to 50 169982 169908
Assembly options
51 to 52 169982 169907
THERM+ FS-I
53 to 54 169986 169908
55 to 56 169986 169907
57 to 58 169990 169908
59 to 60 169990 169907
61 to 62 169994 169908
63 to 64 169994 169907
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
– Cover profiles:
No. 013210 (50 mm)
No. 013410 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169954 169908
22 to 23 169954 169907
24 to 25 169958 169908
26 to 27 169958 169907
28 to 29 169962 169908
30 to 31 169962 169907
32 to 33 169966 169908
34 to 35 169966 169907
36 to 37 169970 169908
38 to 39 169970 169907
40 to 41 169974 169908
42 to 43 169974 169907
44 to 45 169978 169908
46 to 47 169978 169907
48 to 49 169982 169908
50 to 51 169982 169907
52 to 53 169986 169908
54 to 55 169986 169907
56 to 57 169990 169908
58 to 59 169990 169907
60 to 61 169994 169908
62 to 63 169994 169907
64 169998 169908
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
– Cover profiles:
No. 141104 (50 mm)
No. 141304 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169958 169911
22 to 23 169958 169910
24 to 25 169962 169911
26 to 27 169962 169910
28 to 29 169966 169911
30 to 31 169966 169910
32 to 33 169970 169911
34 to 35 169970 169910
36 to 37 169974 169911
38 to 39 169974 169910
40 to 41 169978 169911
42 to 43 169978 169910
44 to 45 169982 169911
46 to 47 169982 169910
48 to 49 169986 169911
50 to 51 169986 169910
Assembly options
52 to 53 169990 169911
THERM+ FS-I
54 to 55 169990 169910
56 to 57 169994 169911
58 to 59 169994 169910
60 to 61 169998 169911
62 to 63 169998 169910
64 169999 169911
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
– Cover profiles:
No. 141104 (50 mm)
No. 141304 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169958 169911
21 to 22 169958 169910
23 to 24 169962 169911
25 to 26 169962 169910
27 to 28 169966 169911
29 to 30 169966 169910
31 to 32 169970 169911
33 to 34 169970 169910
35 to 36 169974 169911
37 to 38 169974 169910
39 to 40 169978 169911
41 to 42 169978 169910
43 to 44 169982 169911
45 to 46 169982 169910
47 to 48 169986 169911
49 to 50 169986 169910
51 to 52 169990 169911
53 to 54 169990 169910
55 to 56 169994 169911
57 to 58 169994 169910
59 to 60 169998 169911
61 to 62 169998 169910
63 to 64 169999 169911
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
– Cover profiles:
No. 141106 (50 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169962 169913
21 to 22 169962 169912
23 to 24 169966 169913
25 to 26 169966 169912
27 to 28 169970 169913
29 to 30 169970 169912
31 to 32 169974 169913
33 to 34 169974 169912
35 to 36 169978 169913
37 to 38 169978 169912
39 to 40 169982 169913
41 to 42 169982 169912
43 to 44 169986 169913
45 to 46 169986 169912
47 to 48 169990 169913
49 to 50 169990 169912
Assembly options
51 to 52 169994 169913
THERM+ FS-I
53 to 54 169994 169912
55 to 56 169998 169913
57 to 58 169998 169912
59 to 60 169999 169913
61 to 62 169999 169912
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
– Cover profiles:
No. 141106 (50 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169962 169912
22 to 23 169966 169913
24 to 25 169966 169912
26 to 27 169970 169913
28 to 29 169970 169912
30 to 31 169974 169913
32 to 33 169974 169912
34 to 35 169978 169913
36 to 37 169978 169912
38 to 39 169982 169913
40 to 41 169982 169912
42 to 43 169986 169913
44 to 45 169986 169912
46 to 47 169990 169913
48 to 49 169990 169912
50 to 51 169994 169913
52 to 53 169994 169912
54 to 55 169998 169913
56 to 57 169998 169912
58 to 59 169999 169913
60 to 61 169999 169912
■ Technical information
– Pressure profiles:
No. 118010 (56 mm)
– Cover profiles:
No. 141307 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169962 169913
21 to 22 169966 169914
23 to 24 169966 169913
25 to 26 169970 169914
27 to 28 169970 169913
29 to 30 169974 169914
31 to 32 169974 169913
33 to 34 169978 169914
35 to 36 169978 169913
37 to 38 169982 169914
39 to 40 169982 169913
41 to 42 169986 169914
43 to 44 169986 169913
45 to 46 169990 169914
47 to 48 169990 169913
49 to 50 169994 169914
Assembly options
51 to 52 169994 169913
THERM+ FS-I
53 to 54 169998 169914
55 to 56 169998 169913
57 to 58 169999 169914
59 to 60 169999 169913
■ Technical information
– Pressure profiles:
No. 118010 (56 mm)
– Cover profiles:
No. 141307 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169966 169914
22 to 23 169966 169913
24 to 25 169970 169914
26 to 27 169970 169913
28 to 29 169974 169914
30 to 31 169974 169913
32 to 33 169978 169914
34 to 35 169978 169913
36 to 37 169982 169914
38 to 39 169982 169913
40 to 41 169986 169914
42 to 43 169986 169913
44 to 45 169990 169914
46 to 47 169990 169913
48 to 49 169994 169914
50 to 51 169994 169913
52 to 53 169998 169914
54 to 55 169998 169913
56 to 57 169999 169914
58 to 59 169999 169913
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
– Cover profiles:
No. 013005 (50 mm)
No. 013025 (56 mm)
No. 013201 (50 mm)
No. 013400 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169954 169909
21 to 22 169954 169908
23 169954 169907
24 169958 169909
25 to 26 169958 169908
27 169958 169907
28 169962 169909
29 to 30 169962 169908
31 169962 169907
32 169966 169909
33 to 34 169966 169908
35 169966 169907
36 169970 169909
37 to 38 169970 169908
39 169970 169907
40 169974 169909
Assembly options
41 to 42 169974 169908
THERM+ FS-I
43 169974 169907
44 169978 169909
45 to 46 169978 169908
47 169978 169907
48 169982 169909
49 to 50 169982 169908
51 169982 169907
52 169986 169909
53 to 54 169986 169908
55 169986 169907
56 169990 169909
57 to 58 169990 169908
59 169990 169907
60 169994 169909
61 to 62 169994 169908
63 169994 169907
64 169998 169909
■ Technical information
– Pressure profiles:
No. 118005 (50 mm)
No. 118010 (56 mm)
– Cover profiles:
No. 013005 (50 mm)
No. 013025 (56 mm)
No. 013201 (50 mm)
No. 013400 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169954 169908
22 169954 169907
23 169958 169909
24 to 25 169958 169908
26 169958 169907
27 169962 169909
28 to 29 169962 169908
30 169962 169907
31 169966 169909
32 to 33 169966 169908
34 169966 169907
35 169970 169909
36 to 37 169970 169908
38 169970 169907
39 169974 169909
40 to 41 169974 169908
42 169974 169907
43 169978 169909
44 to 45 169978 169908
46 169978 169907
47 169982 169909
48 to 49 169982 169908
50 169982 169907
51 169986 169909
52 to 53 169986 169908
54 169986 169907
55 169990 169909
56 to 57 169990 169908
58 169990 169907
59 169994 169909
60 to 61 169994 169908
62 169994 169907
63 169998 169909
64 169998 169908
■ Technical information
– Pressure profiles:
No. 013018 (50 mm)
No. 013038 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169942 169900
21 to 22 169946 169902
23 169946 169901
24 169946 169900
25 to 26 169950 169902
27 169950 169901
28 169950 169900
29 to 30 169954 169902
31 169954 169901
32 169954 169900
33 to 34 169958 169902
35 169958 169901
36 169958 169900
37 to 38 169962 169902
39 169962 169901
40 169962 169900
Assembly options
41 to 42 169966 169902
THERM+ FS-I
43 169966 169901
44 169966 169900
45 to 46 169970 169902
47 169970 169901
48 169970 169900
49 to 50 169974 169902
51 169974 169901
52 169974 169900
53 to 54 169978 169902
55 169978 169901
56 169978 169900
57 to 58 169982 169902
59 169982 169901
60 169982 169900
61 to 62 169986 169902
63 169986 169901
64 169986 169900
■ Technical information
– Pressure profiles:
No. 013018 (50 mm)
No. 013038 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169946 169902
22 169946 169901
23 169946 169900
24 to 25 169950 169902
26 169950 169901
27 169950 169900
28 to 29 169954 169902
30 169954 169901
31 169954 169900
32 to 33 169958 169902
34 169958 169901
35 169958 169900
36 to 37 169962 169902
38 169962 169901
39 169962 169900
40 to 41 169966 169902
42 169966 169901
43 169966 169900
44 to 45 169970 169902
46 169970 169901
47 169970 169900
48 to 49 169974 169902
50 169974 169901
51 169974 169900
52 to 53 169978 169902
54 169978 169901
55 169978 169900
56 to 57 169982 169902
58 169982 169901
59 169982 169900
60 to 61 169986 169902
62 169986 169901
63 169986 169900
64 169990 169902
■ Technical information
– Pressure profiles:
No. 013008 (50 mm)
No. 013028 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169946 169902
21 to 22 169946 169901
23 169946 169900
24 169950 169902
25 to 26 169950 169901
27 169950 169900
28 169954 169902
29 to 30 169954 169901
31 169954 169900
32 169958 169902
33 to 34 169958 169901
35 169958 169900
36 169962 169902
37 to 38 169962 169901
39 169962 169900
40 169966 169902
Assembly options
41 to 42 169966 169901
THERM+ FS-I
43 169966 169900
44 169970 169902
45 to 46 169970 169901
47 169970 169900
48 169974 169902
49 to 50 169974 169901
51 169974 169900
52 169978 169902
53 to 54 169978 169901
55 169978 169900
56 169982 169902
57 to 58 169982 169901
59 169982 169900
60 169986 169902
61 to 62 169986 169901
63 169986 169900
64 169990 169902
■ Technical information
– Pressure profiles:
No. 013008 (50 mm)
No. 013028 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169946 169901
22 169946 169900
23 169950 169902
24 to 25 169950 169901
26 169950 169900
27 169954 169902
28 to 29 169954 169901
30 169954 169900
31 169958 169902
32 to 33 169958 169901
34 169958 169900
35 169962 169902
36 to 37 169962 169901
38 169962 169900
39 169966 169902
40 to 41 169966 169901
42 169966 169900
43 169970 169902
44 to 45 169970 169901
46 169970 169900
47 169974 169902
48 to 49 169974 169901
50 169974 169900
51 169978 169902
52 to 53 169978 169901
54 169978 169900
55 169982 169902
56 to 57 169982 169901
58 169982 169900
59 169986 169902
60 to 61 169986 169901
62 169986 169900
63 169990 169902
64 169990 169901
■ Technical information
– Pressure profiles:
No. 013007 (50 mm)
No. 013027 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169946 169900
21 169950 169902
22 to 23 169950 169901
24 169950 169900
25 169954 169902
26 to 27 169954 169901
28 169954 169900
29 169958 169902
30 to 31 169958 169901
32 169958 169900
33 169962 169902
34 to 35 169962 169901
36 169962 169900
37 169966 169902
38 to 39 169966 169901
40 169966 169900
Assembly options
41 169970 169902
THERM+ FS-I
42 to 43 169970 169901
44 169970 169900
45 169974 169902
46 to 47 169974 169901
48 169974 169900
49 169978 169902
50 to 51 169978 169901
52 169978 169900
53 169982 169902
54 to 55 169982 169901
56 169982 169900
57 169986 169902
58 to 59 169986 169901
60 169986 169900
61 169990 169902
62 to 63 169990 169901
64 169990 169900
■ Technical information
– Pressure profiles:
No. 013007 (50 mm)
No. 013027 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169950 169902
21 to 22 169950 169901
23 169950 169900
24 169954 169902
25 to 26 169954 169901
27 169954 169900
28 169958 169902
29 to 30 169958 169901
31 169958 169900
32 169962 169902
33 to 34 169962 169901
35 169962 169900
36 169966 169902
37 to 38 169966 169901
39 169966 169900
40 169970 169902
41 to 42 169970 169901
43 169970 169900
44 169974 169902
45 to 46 169974 169901
47 169974 169900
48 169978 169902
49 to 50 169978 169901
51 169978 169900
52 169982 169902
53 to 54 169982 169901
55 169982 169900
56 169986 169902
57 to 58 169986 169901
59 169986 169900
60 169990 169902
61 to 62 169990 169901
63 169990 169900
64 169994 169902
■ Technical information
– Pressure profiles:
No. 013014 (50 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 169954 169906
21 to 22 169954 169905
23 169954 169904
24 to 25 169958 169906
26 169958 169905
27 169958 169904
28 169962 169906
29 to 30 169962 169905
31 169962 169904
32 169966 169906
33 to 34 169966 169905
35 169966 169904
36 169970 169906
37 to 38 169970 169905
39 169970 169904
40 169974 169906
Assembly options
41 to 42 169974 169905
THERM+ FS-I
43 169974 169904
44 169978 169906
45 to 46 169978 169905
47 169978 169904
48 169982 169906
49 to 50 169982 169905
51 169982 169904
52 169986 169906
53 to 54 169986 169905
55 169986 169904
56 169990 169906
57 to 58 169990 169905
59 169990 169904
60 169994 169906
61 to 62 169994 169905
63 169994 169904
64 169998 169906
■ Technical information
– Pressure profiles:
No. 013014 (50 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
20 to 21 169954 169905
22 169954 169904
23 169958 169906
24 to 25 169958 169905
26 169958 169904
27 169962 169906
28 to 29 169962 169905
30 169962 169904
31 169966 169906
32 to 33 169966 169905
34 169966 169904
35 169970 169906
36 to 37 169970 169905
38 169970 169904
39 169974 169906
40 to 41 169974 169905
42 169974 169904
43 169978 169906
44 to 45 169978 169905
46 169978 169904
47 169982 169906
48 to 49 169982 169905
50 169982 169904
51 169986 169906
52 to 53 169986 169905
54 169986 169904
55 169990 169906
56 to 57 169990 169905
58 169990 169904
59 169994 169906
60 to 61 169994 169905
62 169994 169904
63 169998 169906
64 169998 169905
■ Technical information
– Pressure profiles:
No. 013300 (50 mm)
No. 013310 (56 mm)
– T74 = Infill thickness.
Infill thickness
No. socket No. sealing sleeve
mm
24 to 25 169942 169901
26 169942 169900
27 169946 169902
28 to 29 169946 169901
30 169946 169900
31 169950 169902
32 to 33 169950 169901
34 169950 169900
35 169954 169902
36 to 37 169954 169901
38 169954 169900
39 169958 169902
40 to 41 169958 169901
42 169958 169900
43 169962 169902
44 to 45 169962 169901
Assembly options
46 169962 169900
THERM+ FS-I
47 169966 169902
48 to 49 169966 169901
50 169966 169900
51 169970 169902
52 to 53 169970 169901
54 169970 169900
55 169974 169902
56 to 57 169974 169901
58 169974 169900
59 169978 169902
60 to 61 169978 169901
62 169978 169900
63 169982 169902
64 169982 169901
■ Technical information
– In the scaffolding fixation area the base profile scaffolding fixation
no. 167793 (50) or no. 167794 (56) has to be mounted.
– Application of flat pressure profile possible from an infill thickness of 32 mm.
– The number and position of the fixation points depends on the specific requirements
of the scaffold. The max. load transmission into the curtain wall construction is
system independant and can be taken from the table Representative parameter.
– T183 = Offset posts.
– T184 = Height of scaffold.
– T281 = Black.
– T282 = White.
– T283 = Scaffolding fixation I.
– T284 = Installation example for transom.
– T303 = Situation after removing the eye bolt. Representative parameter
T283
T303
■ Technical information
– Applicable for structural profile width from 50 to 60 mm.
– For use from a threaded tube depth of 120 mm.
– Mounting bracket optional with fixation bracket profile 110/120
no. 146005 (in-house production) or fixation bracket 80
no. 166005 (pre-fabricated).
– Mounting
- 2 mounting units no. 166110.
– Mullion handling
- 2 roand holes Ø 15 mm, offset 40 mm.
– During the detailed planning a statical proof has to be provided.
(Edge distances, bearing stress, etc. of the structural profile are
to be taken into account). For detailed in for mation see Processing.
Assembly options
THERM+ FS-I
56
ile
r of
a lp
c tur
ru
St
Compensation of tolerances
Lower mullion
Approvable loads fixation bracket 166010
with mounting unit 166115
Compensation of tolerances
Approvable Floating-point Floating-point
loads fixing 50 fixing 56
FS: 5.2 kN 7.4 kN
FD: 5.2 kN 7.4 kN
FV: 0 kN 0 kN
Assembly options
THERM+ FS-I
Compensation of tolerances
■ Technical information
– Applicable for structural profile width from 50 to 60 mm.
– Mounting bracket optional with fixation bracket profile 110/120
no. 146005 (in-house production) or fixation bracket 120
no. 166015 (pre-fabricated).
– Mounting
- 1 mounting unit no. 166110.
– Mullion handling
- 1 roand hole Ø 15 mm.
– During the detailed planning a statical proof has to be provided.
(Edge distances, bearing stress, etc. of the structural profile are
to be taken into account). For detailed in for mation see Processing.
Assembly options
(50/56)
55** – 227006
THERM+ FS-I
56 227010 227006
57 227032 227006
58 227015 227006
59 227032 227006
60 227020 227006
61 227032 227006
62 227025 227006
63 227032 227006
64 227030 227006
■ Technical information
– = Infill thickness.
– T248 = Compensation gasket.
Connection profile no. 168005 with 2 mm sheet Connection profile no. 168005 with 3 mm sheet
No.
168005
Infill Compensation
Height
thickness gasket PU
mm
mm mm
22 – – –
24 011080 2 100 m
25 011070 3 100 m
26 011077 4 100 m
27 011073 5 100 m
28 011076 6 100 m
29 011074 7 100 m
30 011071 8 100 m
31 011075 9 100 m
33 011072 11 100 m
35 011078 13 50 m
Assembly options
THERM+ FS-I
■ Technical information
– Applicable as an assembly aid or for the fixation of
sheets and connection profiles at hard-to-reach places.
– Clamp thickness 1.5 to 3 mm.
– Fixation with a suitable screw for hole Ø 6 mm.
– T261 = Screw, on-site.
Assembly options
THERM+ FS-I
■ Technical information
– Table for the selection of the compensation gasket see following page.
– The maximum weight of the slim pane above is to be coordinated with RAICO.
– A difference between the glass thicknesses from 10 to 24 mm can be
compensated without exterior glass offset.
– Ensure the tightness of the compensation profiles in the corners
by carefully sealing them.
– T13 = Infill thickness (IT).
IT 1 IT 2 (mm)
(mm) 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54
16 220322 220321 220320
2017
Table for the selection of compensation gasket
Steel curtain wall 50/56 mm
525
Connection profiles
Accessories
THERM+ FS-I
THERM+ FS-I
Assembly options
THERM+ FS-I
Accessories
Assembly options
gasket profile
THERM+ FS-I
24 42 mm 012114 167604 167654 without without without without
25 – – – – – – – –
26 42 mm 012114 167606 167656 2 mm 227010 without without
27 45 mm 012115 167607 167657 3 mm 227032 without without
28 45 mm 012115 167608 167658 4 mm 227015 without without
29 45 mm 012115 167609 167659 5 mm 227032 without without
30 48 mm 012116 167610 167660 6 mm 227020 without without
31 48 mm 012116 167611 167661 7 mm 227032 without without
32 50 mm 012117 167612 167662 8 mm 227025 without without
33 50 mm 012117 167613 167663 9 mm 227032 without without
34 52 mm 012118 167614 167664 10 mm 227030 without without
35 – – – – – – – –
36 52 mm 012118 167616 167666 2 mm 227010 10 mm 227006
37 55 mm 012119 167617 167667 3 mm 227032 10 mm 227006
38 55 mm 012119 167618 167668 4 mm 227015 10 mm 227006
39 55 mm 012119 167619 167669 5 mm 227032 10 mm 227006
40 58 mm 012129 167620 167670 6 mm 227020 10 mm 227006
41 58 mm 012129 167621 167671 7 mm 227032 10 mm 227006
42 60 mm 012123 167622 167672 8 mm 227025 10 mm 227006
43 60 mm 012123 167623 167673 9 mm 227032 10 mm 227006
44 62 mm 012124 167624 167674 10 mm 227030 10 mm 227006
Self-production
IT L angle profile EPDM compen- Syn. compens. Syn. adapt. profile Screw
mm THERM+ 50 I THERM+ 56 I sation profile profile 227006 219040 219044 1 PU = 100 pc(s)
Assembly options
24 14x20x3 14x25x3 without without without 24 mm without
THERM+ FS-I
25 – – – – – – –
26 16x20x3 16x25x3 2 mm 227010 without 24 mm without
27 17x20x3 17x25x3 3 mm 227032 without 24 mm without
28 18x20x3 18x25x3 4 mm 227015 without 24 mm without
29 19x20x3 19x25x3 5 mm 227032 without 24 mm without
30 20x20x3 25x25x3 6 mm 227025 without 24 mm without
31 21x20x3 21x25x3 7 mm 227032 without 24 mm without
32 22x20x3 22x25x3 8 mm 227025 without 24 mm without
33 23x20x3 23x25x3 9 mm 227032 without 24 mm without
34 24x20x3 24x25x3 10 mm 227030 without 24 mm without
35 – – – – – – –
36 26x20x3 26x25x3 2 mm 227010 10 mm 24 mm without Frame Curtain wall
37 27x20x3 27x25x3 3 mm 227032 10 mm 24 mm without fixation fixation
38 28x20x3 28x25x3 4 mm 227015 10 mm 24 mm without 3.9x38 mm 5.5x40 mm
39 29x20x3 29x25x3 5 mm 227032 10 mm 24 mm without no. no.
40 30x20x3 30x25x3 6 mm 227025 10 mm 24 mm without 906018 012113
41 31x20x3 31x25x3 7 mm 227032 10 mm 24 mm without
42 32x20x3 32x25x3 8 mm 227025 10 mm 24 mm without
43 33x20x3 33x25x3 9 mm 227032 10 mm 24 mm without
44 34x20x3 34x25x3 10 mm 227030 10 mm without 44 mm
45 – – – – – – –
46 36x20x3 36x25x3 2 mm 227010 without without 44 mm
47 37x20x3 37x25x3 3 mm 227032 without without 44 mm
48 38x20x3 38x25x3 4 mm 227015 without without 44 mm
49 39x20x3 39x25x3 5 mm 227032 without without 44 mm
50 40x20x3 40x25x3 6 mm 227025 without without 44 mm
51 41x20x3 41x25x3 7 mm 227032 without without 44 mm
52 42x20x3 42x25x3 8 mm 227025 without without 44 mm
■ Technical information
– For the position of assembly angles see
shimming instruction in the Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness (IT).
– T141 = Selection of assembly angle
and screws see table.
– T264 = Gasket optional.
System
Dim. x1 Dim. x 2
width
mm mm
mm
50 4 6.5
56 3 5.5
Assembly
angle
IT EPDM- Synth. Screw
50/56 mm
mm compensation gasket compens. profile 1 PU = 100 pc(s)
40 166020 – – without without
41 166020 – – without without
42 166020 2 mm 227010 without without
43 166020 3 mm 227032 without without
44 166020 4 mm 227015 without without
45 166020 5 mm 227032 without without
46 166020 6 mm 227020 without without
47 166020 7 mm 227032 without without
48 166020 8 mm 227025 without without Frame Curtain wall
49 166020 9 mm 227032 without without fixation fixation
50 166020 10 mm 227030 without without 4.2x38 mm 5.5x40 mm
51 166022 – – – – no. no.
52 166022 2 mm 227010 10 mm 227006 906026 012113
53 166022 3 mm 227032 10 mm 227006
54 166022 4 mm 227015 10 mm 227006
55 166022 5 mm 227032 10 mm 227006
56 166022 6 mm 227020 10 mm 227006
57 166022 7 mm 227032 10 mm 227006
58 166022 8 mm 227025 10 mm 227006
59 166022 9 mm 227032 10 mm 227006
60 166022 10 mm 227030 10 mm 227006
■ Technical information
– For the position of assembly angles see
shimming instruction in the Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness (IT).
– T141 = Selection of assembly angle
and screws see table.
– T264 = Dichtung optional.
System
Dim. x1 Dim. x 2
width
mm mm
mm
50 4 6.5
56 3 5.5
Assembly options
THERM+ FS-I
Assembly
angle
IT EPDM- Synth. Screw
50/56 mm
mm compensation gasket compens. profile 1 PU = 100 pc(s)
40 166020 – – without without
41 166020 – – without without
42 166020 2 mm 227010 without without
43 166020 3 mm 227032 without without
44 166020 4 mm 227015 without without
45 166020 5 mm 227032 without without
46 166020 6 mm 227020 without without
47 166020 7 mm 227032 without without
48 166020 8 mm 227025 without without Frame Curtain wall
49 166020 9 mm 227032 without without fixation fixation
50 166020 10 mm 227030 without without 4.2x38 mm 5.5x40 mm
51 166022 – – – – no. no.
52 166022 2 mm 227010 10 mm 227006 906026 012113
53 166022 3 mm 227032 10 mm 227006
54 166022 4 mm 227015 10 mm 227006
55 166022 5 mm 227032 10 mm 227006
56 166022 6 mm 227020 10 mm 227006
57 166022 7 mm 227032 10 mm 227006
58 166022 8 mm 227025 10 mm 227006
59 166022 9 mm 227032 10 mm 227006
60 166022 10 mm 227030 10 mm 227006
■ Technical information
– For the position of assembly angles see
shimming instruction in the Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness (IT).
– T141 = Selection of assembly angle
and screws see table.
System Profile
width Dim. x Dim. y width
mm mm
50 7 5 50
56 6 4 60
■ Technical information
– For the position of assembly angles see
shimming instruction in the Processing.
– For some system options (e.g. half
gaskets with insertion profile) the height
of the assembly angles has to be
adjusted.
– T13 = Infill thickness (IT).
– T141 = Selection of assembly angle
and screws see table.
System Profile
width Dim. x Dim. y width
mm mm
50 9 5 50
56 8 4 60
Assembly options
Assembly angles and screws
FRAME+ 75 DI for THERM+ I
THERM+ FS-I
Assembly angle for EPDM Synthetic
IT Screw compensation compensation
mm Length / No. 50 mm 56 mm gasket profile
24 42 mm 012114 167604 167654 without without without without
25 – – – – – – – –
26 42 mm 012114 167606 167656 2 mm 227010 without without
27 45 mm 012115 167607 167657 3 mm 227032 without without
28 45 mm 012115 167608 167658 4 mm 227015 without without
29 45 mm 012115 167609 167659 5 mm 227032 without without
30 48 mm 012116 167610 167660 6 mm 227020 without without
31 48 mm 012116 167611 167661 7 mm 227032 without without
32 50 mm 012117 167612 167662 8 mm 227025 without without
33 50 mm 012117 167613 167663 9 mm 227032 without without
34 52 mm 012118 167614 167664 10 mm 227030 without without
35 – – – – – – – –
36 52 mm 012118 167616 167666 2 mm 227010 10 mm 227006
37 55 mm 012119 167617 167667 3 mm 227032 10 mm 227006
38 55 mm 012119 167618 167668 4 mm 227015 10 mm 227006
39 55 mm 012119 167619 167669 5 mm 227032 10 mm 227006
40 58 mm 012129 167620 167670 6 mm 227020 10 mm 227006
41 58 mm 012129 167621 167671 7 mm 227032 10 mm 227006
42 60 mm 012123 167622 167672 8 mm 227025 10 mm 227006
43 60 mm 012123 167623 167673 9 mm 227032 10 mm 227006
44 62 mm 012124 167624 167674 10 mm 227030 10 mm 227006
■ Technical information
– For the position of assembly angles see
shimming instruction in the Processing.
– For some system options (e.g. half
gaskets with insertion profile) the height
of the assembly angles has to be
adjusted.
– T13 = Infill thickness (IT).
– T141 = Selection of assembly angle
and screws see table.
System Profile
width Dim. x Dim. y width
mm mm
50 9 5 50
56 8 4 60
■ Technical information
– For the position of assembly angles see
shimming instruction in the Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– T13 = Infill thickness (IT).
– T141 = Selection of assembly angle
and screws see table.
System Profile
width Dim. x Dim. y width
mm mm
50 20 7.5 50
56 19 6.5 60
Assembly options
THERM+ FS-I
Self-production
IT L angle profile EPDM Synthetic Screw
mm THERM+ 50 I THERM+ 56 I compensation gasket compensation profile 1 PU = 100 pc(s)
28 15x20x2.5 15x25x2.5 – – without without
29 – – – – without without
30 18x20x2.5 18x25x2.5 2 mm 227010 without without
31 – – 3 mm 227032 without without
32 20x20x2.5 20x25x2.5 4 mm 227015 without without
33 – – 5 mm 227032 without without
34 20x20x2.5 20x25x2.5 6 mm 227020 without without
35 – – 7 mm 227032 without without
36 25x20x2.5 25x25x2.5 8 mm 227025 without without Frame Curtain wall
37 – – 9 mm 227032 without without fixation fixation
38 25x20x2.5 25x25x2.5 10 mm 227030 without without 3.9x13 mm 5.5x40 mm
39 – – – – – – no. no.
40 30x20x2.5 30x25x2.5 2 mm 227010 10 mm 227006 230075 012113
41 – – 3 mm 227032 10 mm 227006
42 30x20x2.5 30x25x2.5 4 mm 227015 10 mm 227006
43 – – 5 mm 227032 10 mm 227006
44 30x20x2.5 30x25x2.5 6 mm 227020 10 mm 227006
45 – – 7 mm 227032 10 mm 227006
46 35x20x2.5 35x25x2.5 8 mm 227025 10 mm 227006
47 – – 9 mm 227032 10 mm 227006
48 35x20x2.5 35x25x2.5 10 mm 227030 10 mm 227006
■ Technical information
– Screw connection into the façade in combination
with flat pressure profile: with countersunk screw
DIN EN ISO 14586. Sink assembly angle accordingly
before screwing.
– For the position of assembly angles see shimming
instruction in the Processing.
– For some system options (e.g. half gaskets
with insertion profile) the height of the assembly
angles has to be adjusted.
– *Self-production.
– T13 = Infill thickness (IT).
System Profile
width Dim. x Dim. y width
mm mm
50 12 11 50
56 11 10 60 Selection assembly angles
Façade width
No. Article
mm
224540 Assembly angle 50 50
224545 Assembly angle 56 56
■ Technical information
– Only insulated glass with UV resistance edge
seal or optional with enameling/screen printing
may be used.
– The necessary infill thicknesses have to be
coordinated with the glass supplier.
– The legal glazing instructions have to be taken
into consideration and if necessary an approval in
individual cases has to be obtained.
– The suction discs can be also used as a mechanical
saving in combination with the SG2 system for all
heights larger than 8 m (min. infill thickness 32 mm).
– From an infill thickness of 23 mm possible with
insulating blocks SG.
– Selection of screws see Screw selection.
– Please consider DIN EN 18008, TRLV and TRPV.
to
Assembly options
THERM+ FS-I
Suction disc set 75 Suction disc set 50/90 Suction disc set 56/90
No. 163809 No. 163811 No. 163813
■ Technical information
– Rotate drilling jig for pre-drilling the belay sheet
180° for pre-drilling the belay sheet.
– In for mation on the assembly see Processing.
Integration elements
Integration elements
THERM+ S-I/FS-I
2017 539
540 2017
THERM+ S-I
Integration elements
■ Gaskets
Article No. PU
Exterior glazing gasket 220300 100 m
Interior gasket 11 220324 75 m
Interior stop gasket 7 220337 200 m
Insulating block medial
220611 50 m
gasket
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Assembly angle piece 50/6 167606 10 pc(s)
Integration elements
THERM+ S-I/FS-I
■ Gaskets
Article No. PU
Rope 4 220075 100 pc(s)
Stop gasket 220214 200 m
Glazing gasket 5 to 6 F 220405 100 m
Exterior glazing gasket 4.5 220550 100 m
Exterior noise protection
220552 100 m
gasket
Sealing frame vulcanised 220615.R 1 pc(s)
Sealing frame vulcanised 220615.RT 1 pc(s)
Compensation gasket 2 227010 100 m
■ Gaskets
Article No. PU
Interior gasket 9 220323 100 m
Interior stop gasket 7 220337 200 m
Exterior glazing gasket 220650 100 m
Corner vulc. for med. gask. 220660.R 1 pc(s)
Corner vulc. for med. gask. 220660.RT 1 pc(s)
Compensation gasket 4 227015 100 m
■ Accessories
Article No. PU
Glass carrier 225025 100 pc(s)
Insulation insertion 16/47 227951 50 m
Insulation ins. 20.5/41.5 227966 50 m
Integration elements
THERM+ S-I/FS-I
■ Gaskets
Article No. PU
Rope 3 220065 200 m
Interior glazing gasket
220110 100 m
5 to 6
Cover gasket 220190 100 m
Stop gasket 220214 200 m
Corner vulcanised
220226.R 1 pc(s)
medial gasket
Corner vulcanised
220226.RT 1 pc(s)
medial gasket
■ Accessories
Article No. PU
Driving rod 20 225505 6m
Special flat fillister head 100
230070
screw 4.8x19 pc(s)
Special countersunk
100
sheet metal screw 230075
pc(s)
3.9x13
■ Gaskets
Article No. PU
Rope 3 220065 200 m
Interior glazing gasket
220110 100 m
5 to 6
Cover gasket 220190 100 m
Gasket for pressure
220205 100 m
profile 2/16
Stop gasket 220214 200 m
Corner vulcanised
220226.R 1 pc(s)
medial gasket
Corner vulcanised
220226.RT 1 pc(s)
medial gasket
■ Accessories
Article No. PU
Driving rod 20 225505 6m
Special flat fillister head 100
230070
screw 4.8x19 pc(s)
Integration elements
THERM+ S-I/FS-I
■ Gaskets
Article No. PU
100
Rope 4 220075
pc(s)
Glazing gasket 5 to 6 F 220405 100 m
Exterior glazing gasket 4.5 220550 100 m
Compensation gasket 2 227010 100 m
Piping gasket 320003 200 m
Stop gasket 7 320100 200 m
■ Accessories
Article No. PU
Assembly angle piece 50/6 167606 10 pc(s)
320003
■ Gaskets
Article No. PU
Exterior glazing gasket 220300 100 m
Interior gasket 11 220324 75 m
Stop gasket 7 220339 200 m
Insulating block medial
220611 50 m
gasket
Compensation gasket 2 227010 100 m
■ Accessories
Article No. PU
Assembly angle piece
167606 10 pc(s)
50/6
Integration elements
THERM+ S-I/FS-I
220339
■ Gaskets
Article No. PU
Rope 4 220075 100 pc(s)
Stop gasket 220214 200 m
Glazing gasket 5 to 6 F 220405 100 m
Exterior glazing gasket 4.5 220550 100 m
Exterior noise prot. gasket 220552 100 m
Sealing frame vulcanised 220615.R 1 pc(s)
Sealing frame vulcanised 220615.RT 1 pc(s)
Compensation gasket 2 227010 100 m
■ Gaskets
Article No. PU
Interior gasket 9 220323 100 m
Stop gasket 7 220339 200 m
Exterior glazing gasket 220650 100 m
Corner vulc. for med. gask. 220660.R 1 pc(s)
Corner vulc. for med. gask. 220660.RT 1 pc(s)
Compensation gasket 4 227015 100 m
■ Accessories
Article No. PU
Glass carrier 225025 100 pc(s)
Insulation insertion 16/47 227951 50 m
Ins. insertion 20.5/41.5 227966 50 m
Integration elements
THERM+ S-I/FS-I
■ Gaskets
Article No. PU
Rope 3 220065 200 m
Int. glazing gasket 5 to 6 220110 100 m
Cover gasket 220190 100 m
Stop gasket 220214 200 m
Corner vulcanised
220226.R 1 pc(s)
medial gasket
Corner vulcanised
220226.RT 1 pc(s)
medial gasket
■ Accessories
Article No. PU
Driving rod 20 225505 6m
Special flat fillister head 100
230070
screw 4.8x19 pc(s)
Special countersunk 100
230075
sheet metal screw 3.9x13 pc(s)
■ Gaskets
Article No. PU
Rope 3 220065 200 m
Int. glazing gasket 5 to 6 220110 100 m
Cover gasket 220190 100 m
Gasket for pressure
220205 100 m
profile 2/16
Stop gasket 220214 200 m
Corner vulcanised
220226.R 1 pc(s)
medial gasket
Corner vulcanised
220226.RT 1 pc(s)
medial gasket
■ Accessories
Article No. PU
Driving rod 20 225505 6m
Special flat fillister head 100
230070
screw 4.8x19 pc(s)
Integration elements
THERM+ S-I/FS-I
■ Gaskets
Article No. PU
100
Rope 4 220075
pc(s)
Glazing gasket 5 to 6 F 220405 100 m
Exterior glazing gasket 4.5 220550 100 m
Compensation gasket 2 227010 100 m
Piping gasket 320003 200 m
Stop gasket 7 320100 200 m
■ Accessories
Article No. PU
Assembly angle piece
167606 10 pc(s)
50/6
320003
Thermal insulation
Thermal insulation
THERM+ S-I/FS-I
2017 553
554 2017
THERM+ Thermal insulation
Basic information on curtain wall systems
ΣAgUg + ΣApUp + ΣAmUm + ΣAtUt + ΣAfUf+ Σlf,gΨf,g + Σlm,gΨm,g + Σlt,gΨt,g + ΣlpΨp + Σlm,f Ψm,f + Σlt,f Ψt,f
Ucw =
Acw
Thermal insulation
THERM+ S-I/FS-I
Σ(Ucw, j Acw, j) Σ(Ucw, j Acw, j) = Sum of the products of the thermal transmission coefficients and the respective
Ucw, tot = surfaces of the various modules.
ΣAcw, j ΣAcw, j = Sum of the surfaces of the various elements.
2017 555
THERM+ Thermal insulation
Basic information on curtain wall systems
Glazed surfaces
The glazed surface Ag or the surface of a panel Ap of a component respectively, is the smallest of the surfaces visible from both sides
(see illustrations below). The overlapping of panel or glazing because of the sealings can be neglected.
assembly
556 2017
THERM+ Thermal insulation
Basic information on curtain wall systems
section 1 to 1
Af Am Af
window
section 2 to 2
Panel
Af
At
fixed
glazing
Am
At At
section 5 to 5
Thermal insulation
THERM+ S-I/FS-I
Am
Af
2017 557
THERM+ Thermal insulation
Basic information on curtain wall systems
Representative elements
In order to calculate the UCW-value of a curtain wall it is necessary to select a representative element. It is important that the chosen
element mirrors the surface ratios with various thermal qualities of the overall façade, such as glazings, window parapets and so on,
and how they are attached (by mullion and transom, silicon joint, etc.).
Said element is limited by section planes which must be within an adiabatic range. These may either be
– symmetry planes
or
– planes where the heat flow runs at a right angle to the plane of the curtain wall, i. e. there are no influences from the edge
(for example, having a distance of at least 190 mm to the edge of a window with double glazing).
The illustration below shows the adiabatic lines (in the center of the glass pane, or panel, at a sufficient distance to the frame).
Section planes are permissible here because the heat flow runs at a right angle to the glass panes.
Notice: The section planes must not necessarily be geometrical limits of the elements (such as the frame) to due to the fact that the
center of a frame often is not necessarily an adiabatic limit. This circumstance might be caused by the asymmetrical geometrical
form of the frame, asymmetrical qualities of the material (such as components with differing heat conductivity on both sides of
the frame), or the asymmetrical attachment of the panels in a symmetrical frame.
558 2017
THERM+ Thermal insulation
Basic information on curtain wall systems
Ψg value of glazings
Length-related thermal transmission coefficient Ψm,g, Ψt,g and Ψf,g in W/(mK)
Chart B.1
Distance pieces made of aluminium and steel in mullion or transom profiles Ψm,g, Ψt,g
Appendix B DIN EN ISO 12631
Timber to Aluminium 0.08 0.11
Metal frames with di 100 mm: 0.13 di 100 mm: 0.17
thermal separation di 200 mm: 0.15 di 200 mm: 0.19
Chart B.2 Thermally improved distance pieces in mullion profiles or transom profiles Ψm,g, Ψt,g
Appendix B DIN EN ISO 12631 (See Chapter 2.1.2 on a definition of thermally improved distance pieces.)
Timber to Aluminium 0.06 0.08
Metal frames with di 100 mm: 0.09 di 100 mm: 0.11
thermal separation di 200 mm: 0.10 di 200 mm: 0.12
Chart B.3 Distance pieces made of aluminium or steel Ψf,g in window elements
Appendix B DIN EN ISO 12631 (also insert elements in façades)
Timber and synthetics 0.06 0.08
Metal frames with
0.08 0.11
thermal separation
Metal frames without
0.02 0.05
thermal separation
Thermal insulation
THERM+ S-I/FS-I
2017 559
THERM+ Thermal insulation
Basic information on curtain wall systems
Ψg-values in W/(mK)
System Double heat Triple heat Double heat Triple heat Double heat Triple heat
absorbing absorbing absorbing absorbing absorbing absorbing
glazing glazing glazing glazing glazing glazing
Metal-timber-façades Metal-façades
Multitech 0.055 0.050 0.075 0.062 0.079 0.065
Thermobar 0.055 0.050 0.076 0.063 0.081 0.066
SWISSPACER Ultimate 0.056 0.050 0.076 0.063 0.081 0.066
Super Spacer TriSeal/
0.056 0.051 0.077 0.064 0.081 0.067
T-Spacer Premium
Super Spacer TriSeal/
0.058 0.053 0.079 0.066 0.084 0.069
T-Spacer Premium Plus
Ködispace 0.062 0.057 0.086 0.073 0.091 0.076
Ködispace 4SG 0.064 0.059 0.089 0.075 0.094 0.079
Nirotec EVO 0.065 0.061 0.091 0.077 0.096 0.081
SWISSPACER Advance 0.066 0.064 0.091 0.082 0.097 0.086
Chromatech Ultra F 0.066 0.061 0.092 0.078 0.098 0.082
Thermix TX Pro 0.068 0.063 0.094 0.081 0.100 0.085
TGI-Spacer M 0.068 0.063 0.095 0.081 0.100 0.085
Thermix TX.N plus 0.069 0.064 0.096 0.082 0.100 0.086
IGK 611 0.065 0.060 0.090 0.076 0.095 0.080
Nirotec 017 0.083 0.080 0.120 0.100 0.130 0.110
Chromatech 0.086 0.083 0.120 0.110 0.130 0.120
Aluminium ~ 0.120 ~ 0.120 ~ 0.150 ~ 0.150 ~ 0.150 ~ 0.150
Thermoflex* 0.042 0.037 0.056 0.045 0.059 0.047
*Only valid for hotmelt edge sealing.
Values taken from the technical data sheet of the German Bundesverband Flachglas.
For glass thicknesses > 6 mm the mentioned Ψ-values have to be increased.
Outer pane: increase of 0.001 W/(mK) per mm higher glass thickness
Inner pane: increase of 0.002 W/(mK) per mm higher glass thickness
For glass thicknesses < 6 mm the correction values mentioned above may be deducted.
The influence of increasing the glass thickness of the middle pane in case of triple heat absorbing glazing is not significant.
For further information see „Guideline ‚warm edge‘ - for windows and curtain walls“ - BF leaflet 004/2008 - release may 2016
560 2017
THERM+ Thermal insulation
Basic information on curtain wall systems
Outside Inside
Interspace between
glass panes
Spacer
Secondary seal
Thermal insulation
THERM+ S-I/FS-I
2017 561
THERM+ Thermal insulation
Basic information on curtain wall systems
Ψg-values in W/(mK)
562 2017
THERM+ Thermal insulation
Basic information on curtain wall systems
Ψg-values in W/(mK)
2017 563
THERM+ Thermal insulation
Basic information on curtain wall systems
Ψg-values in W/(mK)
564 2017
THERM+ Thermal insulation
Basic information on curtain wall systems
Ψg-values in W/(mK)
2017 565
THERM+ Thermal insulation
Basic information on curtain wall systems
Ψp-value of panels
1 1
3
3
2 4 2
4
6 5 5
Abbreviations: 1 Aluminium 2.5 mm/Steel 2.0 mm Abbreviations: 1 Aluminium 2.5 mm/Steel 2.0 mm
2 Insulating material λ = 2 Insulating material λ =
0.025 W/(mK) to 0.04 W/(mK) 0.025 W/(mK) to 0.04 W/(mK)
3 Air filled interspace 0 to 20 mm 3 Aluminium 2.5 mm/Glass 6 mm
4 Aluminium 2.5 mm/Glass 6 mm 4 Distance piece λ = 0.2 W/(mK) to 0.4 W/(mK)
5 Distance piece λ = 0.2 W/(mK) to 0.4 W/(mK) 5 Aluminium
6 Aluminium
566 2017
THERM+ Thermal insulation
Basic information on curtain wall systems
The Ψ-value between mullion/transom and clamping frame (Ψm/t,f-value) can be calculated according to DIN EN ISO 10077-2 or read
from Chart B.6 DIN EN ISO 12631 if no measuring results are available.
Length-related thermal
Type of transmission coefficient
Illustration Description
attachment Ψm,f or Ψt,f
W/(mK)
in the mullion/transom,
with extended exterior
D aluminium profile and 0.07
filling material of low heat
conductivity
(λ ≤ 0.3 W/(mK))
2017 567
THERM+ Thermal insulation
Basic information in general
Up-values of panels
The Up-values of panels are available from the panel manufacturer.
Uf values for RAICO window systems
For the values of all FRAME+ aluminium window systems, please see chapter Thermal insulation in our catalogues FRAME+
aluminium window systems.
Uf-values for RAICO door systems
The Uf-values of RAICO door systems 75 DI are shown in chapter Thermal insulation in our catalogues FRAME+ aluminium door systems.
Uf-values for RAICO curtain wall systems
For the Uf-values of RAICO curtain wall systems, please refer to the catalogues THERM+, chapter Thermal insulation.
Influence of screws
Calculating the U-values of mullions and transoms of a stick-system façade (Um/Ut) according to DIN EN ISO 10077-2,
the influence of screws acting as an additional thermal bridge is not considered.
Therefore, that influence’s value must be added as well: Um/t = U0 + ΔU
Abbreviations: Um/t Thermal transmission coefficient mullion/transom considering the influence of the screws
U0 Thermal transmission coefficient mullion/transom without the influence of the screws
ΔU Thermal transmission coefficient of the screws
ΔU can be determined by means of the following procedures:
– Calculation according to DIN EN ISO 10211
– Calculation according to DIN EN ISO 12631, Appendix C
– Measuring according to DIN EN 12412-2
– Reading from Chart 2 DIN EN ISO 12631
Chart 2 in DIN EN ISO 12631:
Important! Regarding the Uf-values of mullions and transoms illustrated in the catalogues THERM+, the influence of the
screws as determined by the ift Rosenheim has been considered.
568 2017
THERM+ Thermal insulation
Basic information in general
Annotation : The listed thermal transmission coefficients in the chart above have been calculated according to EN 673. They are
valid for the listed emission values and gas concentration rates. With certain glazings, the emission values and/or the gas
concentration rates may change by and by. Procedures for evaluating the influence of fatigue on the thermal qualities are
described in EN 1279-1 [12] and EN 1279-3 [13].
2017 569
THERM+ Thermal insulation
Basic information in general
cold
cold
SZR = Interspace between glass panes
In case of inclined glazing, a differentiation must be made between double and triple glazing, as these change differently with higher
installation angles.
Depending on the installation angle above the vertical plane, the Ug values of roof glazing can be adapted proportionally. As a result,
the Ug-values of a glazing change acc. to the publication “Geneigt ist anders“ by Dipl.-Phys. Michael Rossa, from the Institut für Fenster-
technik in Rosenheim (Institute for Window Technology) change with the following values:
Intermediate values can be calculated by linear Interpolation between the two closest points.
Reading off example :
Ug(90°) = 1.1 W/(m2K) of a double glazing
Ug(30°) = 1.1 W/(m2K) x 130% = 1.4 W/(m2K)
For a more exact calculation of the Ug-value, it can be calculated in accordance with DIN EN 673, Chapter 5.4.3.
As an alternative, a glass calculation software such as e.g. Silverstar glaCE, can be used.
570 2017
THERM+ Thermal insulation
Basic information on window systems
General
Used symbols and indices, general definitions
Indices as used
cw Curtain wall
f Frame
g Glass
m Mullion
p Panel
t Transom
w Window
– The unit is
2017 571
THERM+ Thermal insulation
Basic information on window systems
Important:
If the perimeter lg, or lp respectively, and the interior and exterior frame surfaces Af differ, the major value between the two is used. For
the glass surface Ag or panel Ap, the smaller value is to be used.
572 2017
THERM+ Thermal insulation
Basic information on window systems
The ψg-value can be calculated according to EN ISO 10077-2, or read from charts E.1 and E.2 in EN ISO 10077-1. Chart E.1 is valid for
distance pieces made of aluminium and stainless steel, chart E.2 relates to distance pieces with improved thermal conductivity.
Distance pieces with improved thermal conductivity are those in accordance with the following formula:
Σ(d·λ) ≤ 0.007
The total sum relates to any heat flows parallel to the principal heat flow direction.
The thickness d is measured vertically to the main heat flow direction; the values regarding the thermal conductivity of distance pieces
should be taken from ISO 10456 or ISO 10077-2.
(d1 · λ1) λ1
d1
d1
d2 (d2 · λ2)
hollow distance pieces Solid distance pieces
Σ(d·λ) = 2(d1 · λ1) + (d2 · λ2) Σ(d·λ) = (d1 · λ1)
2017 573
THERM+ Thermal insulation
Um,t -values S-I
■ Technical information
– Um- and Ut value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.19.
– Values also valid for all approved interior gasket variants.
– Values valid for exterior gasket 3 mm and all standard cover profile options.
– The calculations were carried out with a mullion depth (steel tube) of 100 mm.
– T13 = Infill thickness.
Um-values mullion
Ut-values Transom
■ Technical information
– Um- and Ut value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.19.
– Values also valid for all approved interior gasket variants.
– Values valid for exterior gasket 3 mm and all standard pressure profile options.
– The calculations were carried out with a mullion depth (steel tube) of 100 mm.
– T13 = Infill thickness.
Um-values mullion
Ut-values Transom
■ Technical information
– Um- and Ut value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.19.
– Values also valid for all approved interior gasket variants.
– Values also valid for all approved screw connection variants.
– The calculations were carried out with a mullion depth (steel tube) of 100 mm.
– T13 = Infill thickness.
Um-values mullion
Ut-values Transom
■ Technical information
– Um- and Ut value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.19.
– Values also valid for all approved interior gasket variants.
– Values also valid für all standard cover and pressure profile options with insulating block 9.
– The calculations were carried out with a mullion depth (steel tube) of 100 mm.
– T13 = Infill thickness.
Um-values mullion
Ut-values Transom
■ Technical information
– Um- and Ut value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.19.
– Assembly of insulating block 17, no. 151035 for system width 76 mm.
– Values also valid for all approved interior gasket variants.
– Values valid for all standard cover profile options.
– The calculations were carried out with a mullion depth (steel tube) of 100 mm.
– T13 = Infill thickness.
Um-values mullion
Ut-values Transom
■ Technical information
– Um- and Ut value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.19.
– Assembly of insulating block 17, no. 151035 for system width 76 mm.
– Values also valid for all approved interior gasket variants.
– Values valid for all standard pressure profile options.
– The calculations were carried out with a mullion depth (steel tube) of 100 mm.
– T13 = Infill thickness.
Um-values mullion
Ut-values Transom
Um-values mullion
Ut-values Transom
Um-values mullion
Ut-values Transom
■ Technical information
– Um- and Ut value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.19.
– Values also valid for all approved interior gasket variants.
– Values valid for exterior gasket 3 mm and all standard cover profile options.
Execution with glass bite 13 mm (for 50 and 56) and insulating block PH
no. 168513 (50) or 168519 (56).
– The calculations were carried out with a mullion depth (steel tube) of 100 mm.
– All values passive house certified.
– T13 = Infill thickness.
Um-values mullion
Ut-values Transom
THERM+ S-I 76 mm
Um,t-values insulating block P passive house
Mullion section/transom section
■ Technical information
– Um- and Ut value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.19.
– Values also valid for all approved interior gasket variants.
– Values valid for exterior gasket 5 mm and all standard cover profile options.
– The calculations were carried out with a mullion depth (steel tube) of 100 mm.
– All values passive house standard.
– T13 = Infill thickness.
Um-values mullion
Ut-values Transom
■ Technical information
– Um- and Ut value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.19.
– Values also valid for all approved interior gasket variants.
– Values valid for exterior gasket 3 mm and all standard pressure profile options.
Execution with glass bite 13 mm (for 50 and 56) and insulating block PH
no. 168513 (50) or 168519 (56).
– The calculations were carried out with a mullion depth (steel tube) of 100 mm.
– All values passive house certified.
– T13 = Infill thickness.
Um-values mullion
Ut-values Transom
■ Technical information
– Um- and Ut value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.19.
– Values also valid for all approved interior gasket variants.
– Values also valid for all approved screw connection variants.
– The calculations were carried out with a mullion depth (steel tube) of 100 mm.
– All values passive house standard.
– T13 = Infill thickness.
Um-values mullion
Ut-values Transom
60 0.90 0.89
64 0.88 0.87
THERM+ 50 S-I
Ψ-values for curtain walls with FRAME+ elements
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.052 W/(mK) 0.036 W/(mK) -
(without insulation insertion) 40 0.051 W/(mK) 0.034 W/(mK) -
Insulation insertion + 28 0.056 W/(mK) 0.026 W/(mK) 0.022 W/(mK)
glazing rebate insulation 40 0.059 W/(mK) 0.020 W/(mK) 0.018 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.052 W/(mK) 0.036 W/(mK) -
(without insulation insertion) 40 0.051 W/(mK) 0.036 W/(mK) -
Insulation insertion + 28 0.030 W/(mK) 0.020 W/(mK) 0.016 W/(mK)
glazing rebate insulation 40 0.030 W/(mK) 0.020 W/(mK) 0.016 W/(mK)
IT
Outer frame + adapter Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.054 W/(mK) 0.049 W/(mK) -
(without insulation insertion) 44 0.053 W/(mK) 0.048 W/(mK) -
Insulation insertion + 28 0.051 W/(mK) 0.022 W/(mK) 0.024 W/(mK)
glazing rebate insulation 44 0.032 W/(mK) 0.021 W/(mK) 0.024 W/(mK)
586 2017
THERM+ Thermal insulation
Um,t -values S-I
THERM+ 50 S-I
Ψ-values for curtain walls with FRAME+ elements
IT
Outer frame + adapter Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.054 W/(mK) 0.049 W/(mK) -
(without insulation insertion) 44 0.053 W/(mK) 0.048 W/(mK) -
Insulation insertion + 28 0.051 W/(mK) 0.022 W/(mK) 0.024 W/(mK)
glazing rebate insulation 44 0.032 W/(mK) 0.021 W/(mK) 0.024 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 - - -
(without insulation insertion) 40 0.038 W/(mK) 0.029 W/(mK) 0.023 W/(mK)
Insulation insertion + 28 - - -
glazing rebate insulation 40 0.037 W/(mK) 0.025 W/(mK) 0.024 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 - - -
(without insulation insertion) 40 0.006 W/(mK) -0.004 W/(mK) -0.006 W/(mK)
Insulation insertion + 28 - - -
glazing rebate insulation 40 0.014 W/(mK) 0.003 W/(mK) 0.001 W/(mK)
2017 587
THERM+ Thermal insulation
Um,t -values S-I
THERM+ 50 S-I
Ψ-values for curtain walls with FRAME+ elements
IT
Outer frame + adapter Standard Insulating block P Passive house option
mm
Gasket with flap 28 - - -
(without insulation insertion) 40 0.052 W/(mK) 0.045 W/(mK) 0.044 W/(mK)
Insulation insertion + 28 - - -
glazing rebate insulation 40 0.051 W/(mK) 0.041 W/(mK) 0.040 W/(mK)
IT
Outer frame + adapter Standard Insulating block P Passive house option
mm
Gasket with flap 28 - - -
(without insulation insertion) 40 0.052 W/(mK) 0.045 W/(mK) 0.044 W/(mK)
Insulation insertion + 28 - - -
glazing rebate insulation 40 0.051 W/(mK) 0.041 W/(mK) 0.040 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.050 W/(mK) 0.036 W/(mK) -
(without insulation insertion) 40 0.051 W/(mK) 0.036 W/(mK) -
Insulation insertion + 28 0.031 W/(mK) 0.022 W/(mK) 0.020 W/(mK)
glazing rebate insulation 40 0.030 W/(mK) 0.021 W/(mK) 0.018W/(mK)
588 2017
THERM+ Thermal insulation
Um,t -values S-I
THERM+ 50 S-I
Ψ-values for curtain walls with FRAME+ elements
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.097 W/(mK) 0.083 W/(mK) -
(without insulation insertion) 40 0.058 W/(mK) 0.041 W/(mK) -
Insulation insertion + glazing rebate 28 0.073 W/(mK) 0.065 W/(mK) 0.060 W/(mK)
insulation + frame rebate insulating block 40 0.034 W/(mK) 0.023 W/(mK) 0.019 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.100 W/(mK) 0.085 W/(mK) -
(without insulation insertion) 40 0.059 W/(mK) 0.041 W/(mK) -
Insulation insertion + glazing rebate 28 0.084 W/(mK) 0.070 W/(mK) 0.064 W/(mK)
insulation + frame rebate insulating block 40 0.043 W/(mK) 0.024 W/(mK) 0.019 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.076 W/(mK) 0.060 W/(mK) -
(without insulation insertion) 48 0.058 W/(mK) 0.039 W/(mK) -
Insulation insertion + 28 0.054 W/(mK) 0.042 W/(mK) 0.028 W/(mK)
glazing rebate insulation 48 0.031 W/(mK) 0.015 W/(mK) 0.004 W/(mK)
2017 589
THERM+ Thermal insulation
Um,t -values S-I
THERM+ 50 S-I
Ψ-values for curtain walls with WING elements
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.030 W/(mK) 0.017 W/(mK) -
(without insulation insertion) 40 0.017 W/(mK) 0.010 W/(mK) -
Insulation insertion + 28 0.035 W/(mK) 0.010 W/(mK) 0.010 W/(mK)
glazing rebate insulation 40 0.035 W/(mK) 0.007 W/(mK) 0.006 W/(mK)
590 2017
THERM+ Thermal insulation
Um,t -values FS-I
FRAME+ 90 WB
Determination of the Ucw-value
Example of calculation
Selected components
Curtain wall system THERM+ 50 FS-I
Passive house option
Window system FRAME+ 90 WB
Glazing Ug = 0.58 W/(m2K)
Pane configuration 4/14/4/14/4
with thermal barrier coating
Edge compound Ψg = 0.035 W/(mK)
for curtain wall, Swisspacer
Ultimate acc. to calculation
RAICO
Ψg = 0.031 W/(mK)
for integration window,
Swisspacer Ultimate acc. to
BF data sheet
Insulation option curtain wall Insulating block PH
Insulation option window Insulation insertion and
glazing rebate insulation
Thermal insulation
THERM+ S-I/FS-I
2017 591
THERM+ Thermal insulation
Um,t -values FS-I
FRAME+ 90 WB
Determination of the Uw-value
Calculation example
2400
Area division
b = 2.46 m
h = 2.40 m
bw = 1.172 m
hw = 2.342 m
bf = 0.086 m
bm = 0.050 m
bt = 0.050 m
Mullion
2400
592 2017
THERM+ Thermal insulation
Um,t -values FS-I
FRAME+ 90 WB
Determination of the Uw-value
Calculation example
U f × A f + Ug × A g + ȥ g × l g
Uw =
Aw
W W W
1.1 × 0.575 m² + 0.58 × 2.17 m² + 0.031 × 6.34 m
Uw = m²K m²K mK
2.745 m²
Uw = 0.76 W
m2 K
©2 ¹ © 2 ¹
2017 593
THERM+ Thermal insulation
Um,t -values FS-I
FRAME+ 90 WB
Determination of the Uw-value
Calculation example
Ucw = 0.73 W
m2 K
594 2017
THERM+ Thermal insulation
Um,t -values FS-I
■ Technical information
– Um- and Ut-value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.21 W/(m2K)
for system width 50 mm or 0.19 W/(m2K) for system width 56 mm.
– Values also valid for all approved interior gasket variants.
– Values valid for all exterior gaskets 3 mm and 5 mm and all standard cover profile options.
– The calculations were carried out with the maximum profile depth (threaded tube).
– T13 = Infill thickness.
Um-values mullion
12 2.14 1.99
16 1.87 1.73
20 1.73 1.62
24 1.65 1.54
28 1.59 1.49
32 1.54 1.44
36 1.50 1.41
40 1.47 1.38
44 1.45 1.36
48 1.43 1.34
52 1.41 1.33
56 1.40 1.31
60 1.39 1.30
64 1.38 1.29
Ut-values transom
12 2.18 2.06
16 1.98 1.88
20 1.87 1.77
24 1.79 1.69
28 1.73 1.63
32 1.68 1.58
Thermal insulation
36 1.64 1.55
THERM+ S-I/FS-I
40 1.61 1.52
44 1.59 1.50
48 1.57 1.48
52 1.55 1.46
56 1.54 1.44
60 1.52 1.43
64 1.51 1.42
■ Technical information
– Um- and Ut-value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.21 W/(m2K)
for system width 50 mm or 0.19 W/(m2K) for system width 56 mm.
– Values also valid for all coated standard pressure profiles with visible screw connection.
– Values also valid for all approved interior gasket variants.
– Values valid for all exterior gaskets 3 mm and 5 mm.
– The calculations were carried out with the maximum profile depth (threaded tube).
– T13 = Infill thickness.
Um-values mullion
12 2.31 2.23
16 2.11 2.07
20 2.00 1.97
24 1.91 1.91
28 1.86 1.85
32 1.82 1.81
36 1.79 1.78
40 1.76 1.76
44 1.73 1.74
48 1.71 1.72
52 1.70 1.70
56 1.68 1.69
60 1.67 1.68
64 1.66 1.67
Ut-values transom
12 2.34 2.29
16 2.19 2.16
20 2.09 2.07
24 2.02 2.00
28 1.96 1.95
32 1.92 1.91
36 1.89 1.88
40 1.86 1.86
44 1.84 1.83
48 1.82 1.82
52 1.80 1.80
56 1.79 1.79
60 1.78 1.77
64 1.77 1.76
■ Technical information
– Um- and Ut-value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.21 W/(m2K)
for system width 50 mm or 0.19 W/(m2K) for system width 56 mm.
– Values also valid for all approved interior gasket variants.
– Values also valid for all approved screw connection variants.
– Values valid for all exterior gaskets 2 mm and 3 mm.
– The calculations were carried out with the maximum profile depth (threaded tube).
– T13 = Infill thickness.
Um-values mullion
24 2.05 1.99
28 1.97 1.91
32 1.91 1.86
36 1.86 1.82
40 1.83 1.78
44 1.80 1.76
48 1.77 1.73
52 1.75 1.72
56 1.74 1.70
60 1.72 1.69
64 1.71 1.67
Ut-values transom
24 2.16 2.14
28 2.08 2.06
32 2.02 2.00
36 1.97 1.96
40 1.93 1.92
44 1.90 1.89
Thermal insulation
48 1.87 1.87
THERM+ S-I/FS-I
52 1.85 1.84
56 1.84 1.83
60 1.82 1.81
64 1.81 1.80
■ Technical information
– Um- and Ut-value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.21 W/(m2K)
for system width 50 mm or 0.19 W/(m2K) for system width 56 mm.
– Values also valid for all approved interior gasket variants.
– Values also valid for all standard cover and pressure profile options with insulating block 9.
– The calculations were carried out with the maximum profile depth (threaded tube).
– T13 = Infill thickness.
Um-values mullion
16 1.84 1.76
20 1.69 1.63
24 1.62 1.55
28 1.51 1.50
32 1.47 1.46
36 1.44 1.43
40 1.42 1.41
44 1.40 1.39
48 1.38 1.38
52 1.37 1.37
56 1.36 1.36
60 1.35 1.35
64 1.34 1.34
Ut-values transom
16 1.84 1.80
20 1.72 1.68
24 1.62 1.62
28 1.57 1.57
32 1.53 1.53
36 1.49 1.51
40 1.47 1.48
44 1.45 1.47
48 1.43 1.45
52 1.42 1.44
56 1.41 1.43
60 1.40 1.42
64 1.39 1.41
■ Technical information
– Um- and Ut-value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.21 W/(m2K)
for system width 50 mm or 0.19 W/(m2K) for system width 56 mm.
– Values also valid for all coated standard pressure profiles with visible screw connection.
– Values also valid for all approved interior gasket variants.
– Values valid for exterior gasket 3 mm and 5 mm and all standard cover profile options.
– Values of insulating block P 19 also valid for insulating block 21.
– The calculations were carried out with the maximum profile depth (threaded tube).
– T13 = Infill thickness.
Um-values mullion
24 1.39 - - - 1.34 - - -
28 1.32 - - - 1.27 - - -
32 1.26 1.18 - - 1.22 1.14 - -
36 1.22 1.15 - 1.08 1.18 1.11 - 1.04
40 1.20 1.11 - 0.98 1.16 1.07 - 0.95
44 1.18 1.09 0.99 0.91 1.15 1.05 0.95 0.88
48 1.17 1.08 0.97 0.85 1.13 1.04 0.93 0.83
52 1.16 1.06 0.95 0.83 1.13 1.03 0.92 0.81
56 1.15 1.06 0.94 0.81 1.12 1.02 0.91 0.79
60 1.15 1.05 0.94 0.79 1.11 1.02 0.90 0.78
64 1.14 1.05 0.93 0.78 1.11 1.01 0.90 0.77
Values passive Values passive
house certified house certified
Ut-values transom
24 1.39 - - - 1.35 - - -
28 1.33 - - - 1.29 - - -
32 1.28 1.19 - - 1.25 1.15 - -
Thermal insulation
■ Technical information
– Um- and Ut-value in W/(m2K) acc. to DIN EN ISO 10077-2 including screw influence 0.21 W/(m2K)
for system width 50 mm or 0.19 W/(m2K) for system width 56 mm.
– Values also valid for all approved interior gasket variants.
– Values also valid for all approved screw connection variants.
– Values valid for exterior gasket 2 mm and 3 mm.
– The calculations were carried out with the maximum profile depth (threaded tube).
– T13 = Infill thickness.
Um-values mullion
32 1.30 - - - 1.25 - - -
36 1.19 - - - 1.16 - - -
40 1.15 1.11 - - 1.11 1.07 - -
44 1.11 1.06 - 1.01 1.08 1.03 - 0.98
48 1.08 1.02 - 0.93 1.05 0.99 - 0.90
52 1.07 1.00 0.94 0.87 1.04 0.97 0.90 0.84
56 1.06 0.98 0.90 0.82 1.03 0.95 0.87 0.79
60 1.05 0.97 0.88 0.79 1.02 0.94 0.85 0.77
64 1.04 0.96 0.87 0.77 1.01 0.93 0.84 0.75
Values Values
passive passive
house house
certified certified
Ut-values transom
32 1.29 - - - 1.26 - - -
36 1.20 - - - 1.17 - - -
40 1.16 1.11 - - 1.13 1.08 - -
44 1.13 1.07 - 1.01 1.10 1.04 - 0.97
48 1.11 1.03 - 0.94 1.08 1.01 - 0.91
52 1.09 1.01 0.94 0.89 1.07 0.99 0.91 0.86
56 1.08 1.00 0.91 0.85 1.06 0.97 0.88 0.83
60 1.07 0.99 0.90 0.83 1.05 0.97 0.87 0.81
64 1.07 0.98 0.89 0.82 1.04 0.96 0.86 0.79
Values Values
passive passive
house house
certified certified
THERM+ 50 FS-I
Ψ-values for curtain walls with FRAME+ elements
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.038 W/(mK) 0.031 W/(mK) -
(without insulation insertion) 40 0.036 W/(mK) 0.029 W/(mK) -
Insulation insertion + 28 0.026 W/(mK) 0.022 W/(mK) 0.021 W/(mK)
glazing rebate insulation 40 0.025 W/(mK) 0.020 W/(mK) 0.019 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.040 W/(mK) 0.033 W/(mK) -
(without insulation insertion) 40 0.039 W/(mK) 0.032 W/(mK) -
Insulation insertion + 28 0.019 W/(mK) 0.015 W/(mK) 0.016 W/(mK)
glazing rebate insulation 40 0.019 W/(mK) 0.015 W/(mK) 0.015W/(mK)
IT
Outer frame + adapter Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.043 W/(mK) 0.044 W/(mK) -
(without insulation insertion) 44 0.042 W/(mK) 0.042 W/(mK) -
Insulation insertion + 28 0.023 W/(mK) 0.021 W/(mK) 0.023 W/(mK)
glazing rebate insulation 44 0.023 W/(mK) 0.020 W/(mK) 0.022 W/(mK)
2017 601
THERM+ Thermal insulation
Um,t -values FS-I
THERM+ 50 FS-I
Ψ-values for curtain walls with FRAME+ elements
IT
Outer frame + adapter Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.043 W/(mK) 0.044 W/(mK) -
(without insulation insertion) 44 0.042 W/(mK) 0.042 W/(mK) -
Insulation insertion + 28 0.023 W/(mK) 0.021 W/(mK) 0.023 W/(mK)
glazing rebate insulation 44 0.023 W/(mK) 0.020 W/(mK) 0.022 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 - - -
(without insulation insertion) 40 0.026 W/(mK) 0.024 W/(mK) 0.025 W/(mK)
Insulation insertion + 28 - - -
glazing rebate insulation 40 0.021 W/(mK) 0.018 W/(mK) 0.019 W/(mK)
IT
Outer frame + adapter Standard Insulating block P Passive house option
mm
Gasket with flap 28 - - -
(without insulation insertion) 44 -0.008 W/(mK) -0.010 W/(mK) -0.009 W/(mK)
Insulation insertion + 28 - - -
glazing rebate insulation 44 -0.001 W/(mK) -0.005 W/(mK) -0.004 W/(mK)
602 2017
THERM+ Thermal insulation
Um,t -values FS-I
THERM+ 50 FS-I
Ψ-values for curtain walls with FRAME+ elements
IT
Outer frame + adapter Standard Insulating block P Passive house option
mm
Gasket with flap 28 - - -
(without insulation insertion) 40 0.039 W/(mK) 0.039 W/(mK) 0.041 W/(mK)
Insulation insertion + 28 - - -
glazing rebate insulation 40 0.035 W/(mK) 0.034 W/(mK) 0.035 W/(mK)
IT
Outer frame + adapter Standard Insulating block P Passive house option
mm
Gasket with flap 28 - - -
(without insulation insertion) 40 0.039 W/(mK) 0.039 W/(mK) 0.041 W/(mK)
Insulation insertion + 28 - - -
glazing rebate insulation 40 0.035 W/(mK) 0.034 W/(mK) 0.035 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.038 W/(mK) 0.033 W/(mK) -
(without insulation insertion) 40 0.037 W/(mK) 0.031 W/(mK) -
Insulation insertion + 28 0.025 W/(mK) 0.022 W/(mK) 0.020 W/(mK)
glazing rebate insulation 40 0.024 W/(mK) 0.019 W/(mK) 0.017 W/(mK)
2017 603
THERM+ Thermal insulation
Um,t -values FS-I
THERM+ 50 FS-I
Ψ-values for curtain walls with FRAME+ elements
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.086 W/(mK) 0.082 W/(mK) -
(without insulation insertion) 44 0.044 W/(mK) 0.037 W/(mK) -
Insulation insertion + glazing rebate 28 0.064 W/(mK) 0.062 W/(mK) 0.063 W/(mK)
insulation + frame rebate insulation 44 0.024 W/(mK) 0.020 W/(mK) 0.020 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.089 W/(mK) 0.085 W/(mK) -
(without insulation insertion) 40 0.045 W/(mK) 0.038 W/(mK) -
Insulation insertion + glazing rebate 28 0.076 W/(mK) 0.069 W/(mK) 0.067 W/(mK)
insulation + frame rebate insulation 40 0.027 W/(mK) 0.022 W/(mK) 0.020 W/(mK)
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.087 W/(mK) 0.055 W/(mK) -
(without insulation insertion) 48 0.066 W/(mK) 0.036 W/(mK) -
Insulation insertion + 28 0.051 W/(mK) 0.036 W/(mK) 0.045 W/(mK)
glazing rebate insulation 48 0.033 W/(mK) 0.012 W/(mK) 0.013 W/(mK)
604 2017
THERM+ Thermal insulation
Um,t -values FS-I
THERM+ 50 FS-I
Ψ-values for curtain walls with WING elements
IT
Integration outer frame Standard Insulating block P Passive house option
mm
Gasket with flap 28 0.009 W/(mK) 0.015 W/(mK) -
(without insulation insertion) 40 0.012 W/(mK) 0.018 W/(mK) -
Insulation insertion + 28 0.027 W/(mK) 0.009 W/(mK) 0.010 W/(mK)
glazing rebate insulation 40 0.029 W/(mK) 0.006 W/(mK) 0.008 W/(mK)
Thermal insulation
THERM+ S-I/FS-I
2017 605
606 2017
Technical Conditions
2017 607
Technical Conditions
DIN 18056 – Window walls, dimensioning and DIN V ENV 1630 – Windows, doors, closings-off – burglary
construction inhibition – testing procedures for deter-
DIN 18073 – Closing-off by rolling elements, sun pro- mining the resistance against manual
tection devices and blinds in construction, attempts at burglary
definition of terms and requirements DIN V 18103 – Burglary-inhibiting doors, definition of
DIN 18095 – Parts 1, 2 smoke protection doors terms, requirements; testing, labeling
DIN 18201 – Tolerances in construction, definition of DIN V 18054 – Burglary-inhibiting doors, definition of
terms, basics, application, and inspection terms, requirements; testing, labeling
DIN 18202 – Tolerances in high-building, buildings DIN EN 1522 – Windows, doors, closings-off – inhibition
of full-penetration shots – requirements
DIN 18263 – Part 1 and Part 4, locks and hardware,
and classification
door locking devices with hydraulic
absorption DIN EN 1523 – Windows, doors, closings-off - inhibition
of full-penetration shots – requirements
DIN EN 1154 – Door locking devices with hydraulic
and testing procedures
absorption, automatic door closers with
linear operation, door closers TRLV – Technical regulations for the usage of
glazings with linear supports
DIN EN 1155 – Door closers with hydraulic absorption:
lockable door closers with and without TRAV – Technical regulations for the usage of
override glazings with anti-fall guards
DIN 18273 – Door handle fittings, doors with protection
against fire and smoke All our systems and technical products have been developed
in accordance with the preliminaries and conditions of the Deut-
DIN 18351 – VOB (German Construction Contract
Procedures), Part C General technical sche Institut für Normung e. V. (DIN, i. e. German Institute for
contractual terms for construction work Industrial Norms). In individual cases, deviations from norms
and façade works valid outside the coverage of DIN standards may occur. Our
DIN 18357 – VOB (German Construction Contract customers are advised in any case to make comparisons with
Procedures), Contracting rules for award valid national norms and standards as well.
of public works Part C, General technical
regulations for construction work, hard- Quality control
ware works The features and functions of our systems, as described and
DIN 18358 – VOB (German Construction Contract evaluated in test reports, certificates etc. can only be expected
Procedures), Contracting rules for award when using original RAICO products. In order to ensure perfect
of public works Part C, General technical quality, only our original parts should be processed.
regulations for construction work, rolling
shutter works Regulations and recommendations
DIN 18360 – VOB (German Construction Contract VDI (Association of German Engineers) regulation 2719 – sound
Procedures), Contracting rules for award protection Chart for determining the exposure categories regarding
of public works Part C, General technical window glazing – Institut für Fenstertechnik e. V. Rosenheim
regulations for construction work, metal (Institute for Window Technology), explanatory notes on glazing
construction work, locksmith works – Institut des Glaserhandwerks für Verglasungstechnik und
DIN 18361 – VOB (German Construction Contract Fensterbau (German glazing crafts institute for glazing techno-
Procedures), Contracting rules for award logy and window construction).
of public works Part C, General technical Systems admitted by building inspection authorities must be
regulations for construction work, glazing manufactured according to the admittance declarations (DIBt).
works
Deviations from the admittance declarations must in any case
DIN 18516 – Parts 1, 3, 4, cladding for external walls be authorized by the superior building supervision authorities.
ventilated at rear
DIN 18545 – Parts 1 to 3, sealing of glazings with 4. Materials and products
sealing compounds
Materials delivered by us have been manufactured according to
DIN 52290 – Parts 1 and 5, assault-inhibiting glazings, applying norms and standards. Materials and products made of
definition of terms; testing of features materials produced outside our area of influence are to be selected
inhibiting full-penetration shots, and
by the processing company at their own accountability.
classification
DIN EN 1063 – Assault-inhibiting glazings, definition of Aluminium
terms; testing of feature inhibiting full- For the manufacture of aluminum windows, façades, etc. we deliver
penetration shots, and classification anodized profiles made of AlMgSi 0.5 F 22 alloy. For specific
DIN EN 356 – Assault-inhibiting glazings; testing of anodizing procedures, such as single-stage procedures, deviating
features inhibiting assault with cutting and specific alloys must be used. Specific alloys can be delivered by
beating tools. Testing of features inhibiting us only upon prior inquiry and agreement from our side.
full-penetration throwing, classification Extruded aluminum sheaths are delivered in accordance with
DIN V ENV 1627 – Windows, doors, closings-off – burglary DIN 17615. We deliver metal sheets and bands in accordance
inhibition – requirements and classification with DIN EN 485, Parts 1 and 2. Various materials and forms
DIN V ENV 1628 – Windows, doors, closings-off – burglary of delivery (profiles, metal sheets, bands) are to be adjusted
inhibition – testing procedures for deter- according to the required looks and appearance.
mining the resistance against static stress
Profiles made of plastic
DIN V ENV 1629 – Windows, doors, closings-off – burglary
inhibition – testing procedures for deter- The qualities of the used molding material corresponds at least
mining the resistance against dynamic im- to the molding material PVC-U, EDLP, 078-25-28 according to
pact
608 2017
Technical Conditions
DIN EN ISO 1163, Parts 1 and 2. Slight flat unevenness caused 5. Construction features
by production are admissible inasmuch as their correct functioning
System profiles
will not be affected.
We only deliver profile systems which have been tested, admitted
Steel and certified, if necessary, by an acknowledged test institute or
Regarding steel parts necessary for load-bearing construction by the DIBt. The processing company will itself select the profile
elements and anchoring constructions, DIN 18800 Part 4 and systems to be used, considering the expected requirements.
DIN 18801 apply. All steel parts no longer accessible after Profile dimensions regarding frame, wing, mullion and transom
assembly must be galvanized. Admitted procedures are hot are to be determined according to statics for profiles and hardware.
galvanization and flame spraying galvanization. DIN EN ISO 1461 For blind frames and sashes, hollow profiles are to be used in
applies regarding the welding spots of galvanized constructions, general.
and the spots where the corrosion protection of the steel parts is Corner connectors and T-connectors
subject to damage during assembly. Parts no longer accessible
after assembly must have a surface protection according to The production of corner connectors, T-connectors, butt joints
DIN 18360 fig. 3.1.8 or higher. and angle couplings for construction elements, by welding,
screwing and bonding, bonding with off-center pins, pressing and
Joining elements bonding, must be done in accordance with the valid regulations. For
an adhesive a cold-hardening two-component glue is to be used.
Connecting elements such as screws, bolts, rivets etc. must
be sufficiently protected against corrosion. If used together with The joints must feature sufficient firmness, stiffness and tightness
aluminum they must be made of specific alloys. Aluminum may throughout the complete profile’s cross-section.
be used for parts exposed to less static stress. System drainage
Under particular climatic or other environmental influences,
The drainage of the system must be provided for. Penetrating water
fixing elements made of stainless steel A4 must be used,
must be drained off in any case. Please refer to the drainage cross
especially when visible outside. The processing company has
section as shown in RAICO’s processing guidelines.
to make sure about their usage at its own accountability.
All openings and joints in the frame (such as screw holes, notches
Hardware of the corner connectors, and the like) must be made tight, particu-
larly regarding the lower horizontal zone. Water tightness at miter
According to our specifications, RAICO hardware and relating joints, joints and crossings of the construction must be ensured.
components are sufficiently dimensioned and protected against
corrosion in regard to the expected exposure and wear. Hard- Assembly of the components
ware parts are to be selected by the processing company according Where the construction makes joints necessary, additional poly-
to the wear and tear expected under normal conditions. Only tuft brushes, or EPDM/chloroprene sealings respectively, must
hardware as approved and admitted by us is to be used. be used for soundless moving and gliding. Where directly joined
Movable hardware parts must be maintained. or screwed profiles and components have been used, functional
Thus the wear and tear of movable parts and their susceptibility sealing bands or interlayers are to be used in order to avoid
to corrosion will be reduced. The intervals for cleaning and care permeability, sound emission caused by expansion, and contact
depend on the environmental conditions erosion.
Glass Static requirements
The particular guidelines issued by glass manufacturers regarding All components must absorb the affecting forces and transfer
the processing of insulation glass and special glass apply. Glass them to the supporting structure of the building. DIN 18056 on
manufacturers must produce triplex glass in general, and duplex window walls, dimensions and processing applies.
glass from a glass thickness of 36 mm and higher on the standing
Wind loads
edge, to ensure even glass load transfer.
Wind loads must be considered according to DIN 1055, Part 4
Sealing compounds for glazing and sealing with the addition on increased suction coefficients (at the building
Used sealing compounds must be resistant to influences of age edges), if no exceeding loads are indicated.
and climate, and have to be malleable or permanently elastic, Superficial loads
depending on the applied load. They must be suitable to their
If the load of a person leaning out affects the transom (when the
intended purpose, in line with DIN 18545 according to all applying
window wing is open), the additional vertical load which is then
individual requirements.
required must be considered as well. In case of ceiling-high infills
Sealing profiles the horizontal superficial loads (caused by persons pressing
against the mullion or transom from the inside) must be accounted
The sealing profiles which are used must be non-hardening and
for.
abrasion-proof, and must keep their elastic qualities including
their reset force to a large extent within the existing temperature Special loads
range. The shore hardness must remain the same with only little Additional loads, such as sun protection devices, scaffolds, etc.
tolerances. Sealing profiles have to be resistant to normal must be considered in the static calculations. Our standard
atmospheric influences. products and systems are not to be used in maritime environments,
swimming pools and spas without prior modifications.
Assembly of various materials
When assembling various materials, it must be ensured that Bending
neither corrosion nor other unfavorable influences occur. The determined flection of mullion and transom must be in
In particular it must be ensured that no disturbing sounds will accordance with the requirements as defined in DIN 18056.
be caused by changes in length as a result of temperature influ-
ences.
2017 609
Technical Conditions
glass panes, must be considered when calculating the admissible caused by released internal stress, deflection and the like in
flection. the profiles must be checked not only before and after cutting,
but also after milling and stamping. The cutting edges must be
Protection against heat and humidity
deburred carefully. Especially the burs from the workpiece must
According to DIN 4108 on heat protection in high-building, building be removed wherever they inhibit correct functioning or result
components are among light external walls when featuring weights in possible accident hazards.
of up to 300 kg/m². The resulting influences on the room climate
During production, the following issues must be carefully observed:
must be particularly considered, above all regarding the type
and location of heating and air conditioning, heat storage, wall a) Accuracy of fit, flush corner connections and joints
surfaces, and the respective solar radiation. The builder’s
requirements are to be tuned to the economical and technical b) Dimensional accuracy of profiles and components
possibilities in window construction. In particular, DIN 4108
c) Build-in of sealings and tightness, fitting accuracy of corners
applies here. Drainage measures must be agreed. The applicable
and joints
insulation and avoidance of thermal bridges must be considered
when external wall claddings, carriers, supports, panels and d) Drainage (dimensioning and distribution)
other fillings are used.
e) Sealing of all profile joints, notches, and screwing
Rear-ventilated wall claddings
Wall claddings and socle wainscotings ventilated from the rear f) Fitting accuracy of the wing bearing
must be done in a fashion that little quantities of water having
g) Damages to the surface
penetrated the ventilation gap are led to the outside in a con-
trolled manner. Inasmuch as is required, anti-drumming devices h) Hardware must be mounted according to the newest state-of-
have to be built in. The openings for entering and escaping venti- the-art technology and to our specific instructions in such a
lation air must be distributed evenly over the width, their total way that the smooth-running motion (by lubrification), correct
resulting in a sufficient cross section. In any case, a rear-ventilated fit of the hardware, and tightness of the component will all be
façade requires a perfectly insulated and airtight wall. ensured.
Sound proofing i) Lubrification of all moving parts (lock bars, scissors, handles, etc.)
For bigger sheet surfaces, claddings, cover profiles and window
sills, anti-drumming materials must be used. VDI guideline 2719 Function test
on the sound protection of windows and DIN 4109 on sound RAICO components, being high-quality items with long life
protection in high-building are the basics. If higher requirements cycles, should fulfill, among others, the following requirements:
than those defined in sound-protection category 2 are demanded,
Tightness against heavy rain
particular requirements must be considered and agreed.
A window’s tightness against water penetration is defined according
Sun protection to DIN EN 12208, and is categorized by four exposure groups.
Sun protection devices and the resulting construction design must The exposure group to be chosen depends on the geographical
be agreed between the processing company and the builder. location, a normal or excessive wind load, the form of the building,
the position of the building and its height. If not agreed otherwise,
Protection against fire and smoke DIN EN 12208 applies.
Due to building regulations and obligations by local authorities
differing regionally, protective measures against fire and smoke Hardware function
must be taken from the tender documentation, or agreed with the Ensuring the easy operation of all hardware.
orderer. Faultless functioning of the safety devices, or the faulty-operation
blockers respectively.
Movement and deformation of building
and building components Surface treatment of aluminum
Building components must not absorb loads from the structure. All component surfaces have to be protected against influences
Snow loads, differences in temperature, as well as lowering and normally expected. The processing company decides at its own
shrinking must be considered. Expansion joints must be done accountability on the suitable individual surface treatment. It will
accounting for differences in temperature from - 20° to + 60° also make sure that specific features of the construction, such as
Centigrade with light surfaces of natural color; with colored and the combination with metals of higher value within the electro-
dark surfaces from -20° to +80° Centigrade. chemical series (Cu, Sn, Pb etc.), will be considered, as well as
specific emissions caused by the individual location including the
effect of sea water. We do not give any warranty for profiles
6. Production
hardware and components which have been anodized or color-
Accuracy grade, surface qualities and deformation risks have to coated outside our area of influence; in particular this applies to
be checked before cutting. For the manufacture and processing combinations of heat-insulated profiles.
of our constructions we provide multiple processing guidelines,
Anodic oxidation
tools, and auxiliary means to the processing company, which
serve as a help to reach the required quality standards. General The surface treatment of components made of aluminum must be
basic processing instructions will not be mentioned here. carried out in accordance with DIN 17611. The look of the surface
in regard to shine, structure, color shade, and evenness, and the
Processing required surface treatment (E0 – E6) are to be taken from the
The focus must be on the angular accuracy during cutting and tender documentation or agreed individually.
assembly in particular. With steel profiles or heat-insulated profiles, For color shading only procedures are admissible which create
fitting pieces should be used for precise cutting. The effect oxidation layers that are color-fast and light resistant without
610 2017
Technical Conditions
exception. For judging varieties in appearance and color, an sion compensation which are soundproof, airtight and watertight
evaluation by means of average or limit samples must be agreed. must be used. During mounting and plastering, door frames should
be planned, also considering heat insulation and moisture barriers.
Please observe:
The E0 procedure is only applicable in case that there are no Sealing
demands whatsoever regarding an even, decorative surface. If not defined otherwise in the tender documentation, the parts of
The E6 procedure may only be applied under the condition that the the building which serve as brick partitions (such as windows, win-
factory-packed aluminum can be transported within an assuredly dow walls, doors, etc.) must be sealed in the joints of the building
short time from the manufacturing factory to the anodizing work- structure and the components by suitable sealing materials. The
shop. The profiles must not be exposed to humidity and/or affected joints must be tight and sealed according to DIN 18360 and DIN
by human sweat, or subjected to lack of packaging during trans- 18540. Bigger hollow spaces at joining walls or joints in the
port, storage, inappropriate handling and the like. If these preli- construction have to be rear-ventilated by using water-repellent
minaries are not observed, RAICO cannot accept any warranty bands to fill the joints, with pore blocking. Only bands are allowable
claims. which can change their volume elastically due to their structure.
Exterior joints and joining walls are sealed by means of permanent
Coating
sealing agents or EPDM foils to be glued or clamped. For proper
Color coating procedures of the surface of aluminum components processing, sealing joints must be clean, dry and greaseless. The
are not standardized. Due to the various possible procedures, sealing joints must be dimensioned according to the instructions
details are to be taken from the tender documentation, or agreed given by the manufacturers producing sealing agents.
with the orderer and RAICO (in case we deliver surface-coated
profiles). Regarding high-gloss colors undesirable effects may Glazing
be more clearly visible than in case of standard coating. This The glazing of window panes, panels, fillings and the like is to be
cannot be influenced by RAICO. At offshore locations and in carried out according to DIN 18361 (glazing work). Glass manufac-
indoor swimming pools with brine water or sea water, filiform turers’ guidelines on glazing procedures must be observed. The
corrosion may occur. In these cases the usage of pre-anodized company in charge of window construction, if not carrying out the
profiles is recommended. Please inquire for more details. glazing itself, upon order receipt must agree on the precise manner
and execution of glazing works with the glazing company before
Protective measures during completion time
placing the order on glass. The glazing contractor has to be
According to VOB (Contracting Rules for Award of Public Works), informed on the selected system type, or way of mounting. The
the building owner is liable to all damages regarding his services guidelines issued by the German Institute of Glazing Crafts
until buy-off through the building owner. For temporarily protecting referring to glazing technology and window construction, and the
the components during completion time, in particular against processing guidelines issued by the sub-suppliers of glass panels
mechanical damage or damaging effects of plaster, mortar, cement, and insulation glass must be considered.
color and the like, adhesive tapes, plastic foils and suitable protec-
tive paint can be used which can be removed later without leaving Wet glazing
traces. For wet glazing the ‘Chart for determining the exposure catego-
ries of window glazing’, published by the German Institute for
Window Technology must be considered.
7. Transport and assembly
During transport and storage, appropriate protective measures Dry glazing
are to be taken in order to avoid damages. Assembly of the com- For dry glazing with duplex sealing profiles, the rebate must
ponents is to be done only after having finished all plastering generally be equipped with a ventilation system and a controlled
work. On demand of the building owner and for a certain com- drainage system towards the outside. Materials used for the
pensation to be agreed on, the components must be protected sealing profiles will be selected according to expected exposure.
against possible damage with the help of protective bands or When processing the sealing profiles it is important that the tole-
foils in case later plastering work is carried out. rances and dimensions of the rebate width without sealing, of the
sealing itself, and of the filling elements (e. g. the glass pane) will
Fastening
be adjusted to each other, ensuring that the adding tolerance
Build-in and bracing must be carried out according to DIN 18056 values will not exceed the maximum allowances, and that they
and DIN 18360. It must be ensured that the bracing safely trans- will remain water-tight (please see processing guidelines).
fers forces from the building component to the structure. The fi- Principally, however, the guidelines on glazing are to be considered.
xing elements must be adjusted to the building shell, supporting
the adjoining profiles in such a way that they will be protected Pressure glazing
against torsion and bending. In case the firmness in the bracing For pressure glazing the specific processing guidelines issued
spots seem doubtful, the orderer must be informed without delay by glass manufacturers and system producers must be followed.
according to VOB/B § 4, Paragraph 3 (German Construction Con-
tract Procedures). If components with moving wings, mullions and Usage of blocks
transoms are used, the blind frames must be mounted in such a With glass panes, panels, fillings and the like, blocks made of
way that the forces emanating from bands, bearings, mullions plastic or impregnated water-proofed hardwood featuring a mini-
and transoms will be transferred to the structure. Each side of the mum length of 10 cm must be used in an expert way dependent
window wall must be joined to the structure at least at two points. on the type of wing and rebate, to ensure that the wings will not
The maximum distance of the bracing spots is 80 cm. The neces- touch and scrape. When single-sheet glazing and insulation
sary assembly clearance, caused by thermal expansion of the glass are used, the guidelines on the use of blocks with even
building components, necessary sealing joints, and dimensional glass panes must be observed (as issued by the German Institu-
changes of the adjacent components has to be controlled by te of Glazing Crafts for Glazing Technology and Window Con-
means of expansion joints. If required, gliding elements for expan- struction).
2017 611
Technical Conditions
Controlled drainage
Rain water and leak water penetrating from other building
components must be collected right above the metal construction,
and drained off in a controlled manner. Water caused by rain,
condensation and leak caught in the construction itself must be
collected and drained off in a controlled manner within the lower
horizontal of each zone, whether applying to glazing zones or
wings with differing varieties of opening.
When collecting this water, the maximum level the water will
rise inside the collecting chamber must be taken into account,
also considering external pressure. The rising level should be at
least 10 mm and must be increased according to the expected
maximum external pressure. Collected water must be drained off
in a controlled manner to the outside, preventing it to penetrate
the building structure.
Cleaning
Assembled components must be cleaned before buyoff, dirt
and soil caused by mounting must be removed. Only allowable
cleaning detergents may be used. Additional cleaning procedures
have been defined in Explanatory Note A 5 on cleaning aluminum
in construction (issued by the German Aluminum Center).
Protective measures
To ensure faultless functioning and long life-cycles of hardware
parts, suitable lubricants and grease have to be applied to moving
hardware elements.
Final inspection
Before delivery of the building components to the orderer, the
following functions must be checked:
a) the evenness of joints between frame and window sash, and
the even circumferential wing bearing
b) the easy motion and correct functioning of all hardware parts
c) the operation blockers
d) the correct and faultless fit of the wing seals
e) the openings for ventilation and drainage of the rebate
612 2017
General terms of sale
§ 1 Validity of the General Terms of Sale separately with reference to this provision in each individual contract or which result from the
1. Our Terms of Sale shall apply exclusively. They shall apply even where we unreservedly nature of the Contract. Furthermore, the delivery period shall only commence subsequent to
effect delivery to the Customer whilst aware of the Customer’s conflicting provisions or pro- the full and faultless fulfilment of all those contractual obligations of the Customer which are
visions at variance with our Terms of Sale. Customer’s diverging General Terms of Business essential and necessary for the performance of our obligation. 6. Should we accept a request
are hereby strictly opposed. These shall only form part of the Contract when their validity for for a change to the contractual services expressed by the Customer subsequent to concluding
each individual contract has been explicitly confirmed in writing by us. We will not accept any the Contract, those delivery periods and deadlines agreed upon shall become non-binding.
differing terms and conditions notwithstanding that we may not have expressly rejected them We shall make every effort to indicate to the Customer new delivery, commissioning and
nor by means of our referring to correspondence with the contractual partner in which refe- acceptance deadlines for the goods he has ordered as swiftly as possible. We shall, however,
rence is made to the contractual partner’s terms and conditions. Conclusion of the Contract be entitled to give priority consideration to other obligations when finding new deadlines in this
shall not fail due to conflicting General Terms of Business. Each provision within these Terms context. 7. In the event of delays in delivery as laid down in the above-mentioned provisions,
and Conditions shall be valid on its own. Our Terms of Sale shall only apply to entrepreneurs a new delivery and/or assembly date shall only be binding subject to written consent by us
pursuant to § 14, Section 1 of the German Civil Code (BGB) and to legal entities under public or an authorised member of our staff. The same shall apply in cases where the date has
law or to special public funds. 2. Where colliding General Terms of Business tally with one become non-binding due to legal regulations. 8. Delivery periods shall extend appropriately
another, the concurring resolutions shall apply. Beyond this, those sections of our Terms or the delivery date shall be postponed by a reasonable period due to circumstances promp-
of Sale shall be deemed accepted where no provision in the Customer’s General Terms of ted by industrial action, in particular strikes or lock-outs, or due to the advent of unforeseen
Business collides with them. On the other hand, those provisions in the Customer’s General hindrances beyond our volition such as breakdowns, energy or raw material shortages, traffic
Terms of Business not fully concurring with the contractual substance of our General Terms disruption, energy supply problems, measures taken on the part of the authorities, sovereign
of Business shall not form part of the Contract. In all other cases jus dispositivum shall apply. interventions or orders in so far as those hindrances are proven to have a significant influence
3. These Terms of Sale shall apply in their current version also for all future contracts on the on the completion or delivery of the items. This shall also apply where such circumstances
delivery of goods and on subsequent deliveries between the Parties in this business relation- have effected upstream suppliers. The same shall apply for hindrances caused by Acts of God.
ship without there being a need for repeated inclusion of, or reference to, these Terms of Sale Likewise, we cannot be held responsible for the circumstances described above where they
after the initial agreement. 4. In the case of written documents appended with a translation occur during an already existent delay. Should the disruption last for over 3 months, each Party
into a foreign language relating to a Contract for which German is the official language, the to the Contract shall be entitled to withdraw from that hitherto unfulfilled section of the Contract
translation shall only serve as information. The German wording alone shall be conclusive in in writing within a period of 2 weeks without recourse to claims for compensation. Should
determining the subject of the Contract. 5. All agreements concluded between ourselves and withdrawal arise, the outlay for work already carried out incl. material must be reimbursed. At
the Customer for the purpose of implementing this Contract must be set down in writing within the request of either Party to the Contract, the respective other Party must declare whether
this Contract. Additional agreements, subsequent changes to the Contract and provisions of he wishes to adhere to the Contract once the 3-month delay period has expired. We shall be
guarantees, in particular assurances of characteristics or the assumption of procurement risks obliged to notify the Customer in writing of any delay at the earliest possible convenience. The
by non-authorised persons, must all be made in writing. same shall apply when the delay ceases to apply. 9. We always reserve the right to honour our
§ 2 Offers/Quotes delivery obligations subject to the correct and timely delivery of our own supplies. 10. In the
1. Offers made by us shall be subject to change. These represent an invitation to the Custo- event of us being responsible for a transgression or failure to observe the delivery periods, the
mer to place a binding offer for the conclusion of a Contract (order) and are therefore not Customer shall be entitled to cancel the Contract in accordance with legal provisions, subse-
yet binding for us at this stage. We are entitled to accept orders within a period of 4 weeks. quent to his setting us a deadline of at least 2 weeks in writing and this deadline also expiring
During such time the Customer is legally bound to honour his order offer. 2. Contracts shall without being met. He may cancel without setting any deadline where the conditions laid down
not be binding for us unless we accept the order by means of written order confirmation. We in § 323, Section 2 of the German Civil Code (BGB) are met. Declarations of cancellation or
shall not be required to oppose a potential Customer’s written order relating to an offer of this refusal and the fixing of final deadlines can only be made in writing. 11. In the event of neglect
kind should the Contract fail to be concluded . 3. Delivery dates are estimates only and are of duty on our part however, we shall only be obliged to compensate for damages where pre-
without obligation unless we have expressly agreed to their being binding. Descriptions and meditation or gross negligence can be ascribed to us or one of our vicarious agents employed.
photographs of our goods and products in catalogues, leaflets, circulars, advertisements and This shall not apply in the case of a firm deal. Legal provisions concerning the burden of proof
price lists, insofar as these are not part of our quotation are always only approximate and shall shall remain unaffected by this.
only become subject of the Contract when this is expressly indicated and laid down in the § 6 On-Demand Delivery
Contract. Drawings, illustrations, dimensions, weights or other performance data shall only 1. We can dispatch orders as part deliveries insofar as these remain within those customary
be binding where this is expressly agreed in writing. 4. We reserve the right to make changes in the trade and are reasonable to the Customer. These part deliveries must each be paid for
at any time to the subject of the Contract prompted by technical progress, rationalisation or separately in accordance with our terms of payment. Once we have effected part delivery,
design requirements insofar as these changes are within those that are customary in the the Customer shall be entitled to assert his rights arising from § 5, Nos. 10 and 11 of these
trade and are reasonable to the Customer. We also reserve the right to make those changes General Terms of Business, also in terms of the entire Contract, should the conditions laid
to colour, weight etc. that are customary in the trade. 5. Should a change to the subject of the down therein prevail and the Customer have no interest in part delivery. 2. Should delivery on
Contract not fall within those customary in the trade and should it also not be reasonable to the demand be agreed upon, we shall be entitled to cancel the Contract and/or claim for damages
Customer, the Customer shall be entitled to cancel the Contract – a right which he can exercise instead of demanding payment where the Customer delays in demanding delivery and we have
in writing within 2 weeks of receiving relevant notification from us. Cancellation at a later date set an appropriate deadline to no avail. Claims for damages shall not be permitted should the
shall be excluded due to the relevant amendment to the Contract having taken effect by then. Customer not be responsible for the delay. Our claim for compensation due to delay pursuant
§ 3 Offer Charges, Offer Documentation and Copyrights to § 280, Section 1, Section 2 of the German Civil Code BGB in conjunction with § 286 of
1. As a rule, the initial processing of an offer is free-of-charge. Further offers and planning the German Civil Code (BGB) shall remain unaffected by this. Alternatively in this case, we
work shall only be free-of-charge when the delivery contract becomes valid and remains shall be entitled to demand the agreed purchase price for preparation of the entire delivery. 3.
so. 2. We reserve ownership and copyrights on illustrations, drawings, designs, sketches, Goods ordered for delivery on demand must be requested in full within no more than 3 months
calculations and other documents; access to these may not be given to third parties without subsequent to order confirmation where no other deadline has been agreed.
our written consent. These may neither be copied nor reproduced in any other manner without § 7 Passing of Risk and Transport
our consent and on request they must be returned to us once the order has been carried out. 1. In the absence of other separate agreements to the contrary, delivery shall be effected ex
3. Those moulds, samples and dies produced by us in order to fulfil the Contract shall remain works at 87772 Pfaffenhausen. This shall also apply for part deliveries. 2. Where the goods
our property. Furthermore, we shall not be obliged to surrender these to the Customer even are sent to the Customer at his request or as agreed, the risk of accidental loss/destruction
if the price for these has been indicated separately in the Contract or invoice, in the absence and accidental deterioration shall pass (insofar as this is legally permitted) to the Customer
of explicit contractual agreements to the contrary. We shall be entitled to the copyrights for as soon as the goods leave our works - also in the case of part deliveries. This shall apply
the said moulds, samples and dies. 4. With goods manufactured to the Customer’s drawings, regardless of whether the goods are dispatched from the place of fulfilment or from another
specimens or other specifications, the Customer shall assume liability where patents and other location and regardless of who bears the freight costs or who transported the goods to the
copyrights of third parties are violated. The Customer shall undertake to release us from any Customer or to a forwarding agent. 3. Where those goods to be dispatched to the Customer or
such claims to this effect. collected by the Customer pursuant to the above provision are surrendered to the forwarding
§ 4 Prices agent or the Customer at the works, the risk shall then pass to the Customer to the extent
1. Unless agreed otherwise, all prices shall be net “ex works” plus statutory VAT valid at the described above. 4. In the absence of other agreements to the contrary, we shall determine
invoice issue date. Additional costs such as packaging, freight, forwarding expenses, customs, the means of transport and the transport route chosen here without there being any onus on
assembly, insurance and bank charges shall be charged separately. 2. In the absence of any us to select the fastest and cheapest option here. Where the Customer so wishes we shall
other agreement to the contrary, we shall be bound to the prices agreed for a period of 30 insure the consignment against damage incurred during transit, storage and assembly on
days. Should costs then change (in particular due to wage settlements or changes in the cost behalf and at the cost of the Customer. Where the Customer’s place of business is both place
of materials) once the commitment period has come to an end but prior to delivery, we shall of performance and place of effect as a result of an explicit agreement, we shall be entitled
be entitled to alter the agreed prices respectively. On request we shall provide proof of this to insure the consignment against damage incurred during transit, storage and assembly on
change in costs. 3. With repeat orders prices shall be agreed upon afresh. Should no such behalf and at the cost of the Customer. 5. Where the goods are transported by third parties and
agreement materialise, we shall be entitled to set the prices unilaterally at our discretion. 4. where the goods remain uninsured, particularly at the explicit request of the Customer, these
Where value added tax is not included in our invoice - particularly because notification by the goods shall be transported at the Customer’s own risk. 6. Insofar as we bear the transport risk
Customer suggests an “intracommunity” delivery pursuant to §, 4 No. 1 b in conjunction with pursuant to the above provisions, the Customer shall be obliged to facilitate the settlement of
§ 6 a of the German VAT law (UstG) and because we shall be subject to subsequent VAT (§ claims with insurance companies for us to the best of his endeavours. More specifically, the
6 a, IV of the German VAT law - UStG) - the Customer shall be obliged to pay us the sum Customer must satisfy himself of the condition of the consignment immediately on its arrival
we shall be charged in this context. This obligation shall stand regardless of whether we are and must have any possible damage in transit assessed forthwith by the relevant body (station
subsequently required to pay value added tax, turnover tax on imports or any comparable of arrival, delivery post office, forwarding agent) and must relay this information to us without
taxes domestically or abroad. 5. If on any given delivery date, which is at least four months delay. Where the insurance company effects reduced payment to us due to insufficient involve-
after the date on which the contract was concluded, any changes should occur to the basis on ment of the Customer in assessing the damage and in settling the claim, we shall be entitled
which prices have been established (e.g. an increase in the price charged for raw materials, to charge the Customer the insurance company’s shortfall in payment. 7. Where the goods are
materials, wages, transportation or storage), we shall reserve the right to adapt our prices ready for dispatch and where their dispatch or acceptance is delayed for reasons for which we
accordingly after informing the purchaser of this change, whereby the individual cost elements are not responsible, the risk shall pass to the Customer on receipt of notification announcing
and their increase shall be given a fair weighting in determining any new prices. In the event the goods’ readiness for dispatch. The same shall apply where the goods are not called up for
that individual cost elements should increase whilst others decrease, this shall also be taken delivery within the set period in the case of delivery on call.
into consideration when determining the new price. § 8 Acceptance
§ 5 Lead Time, Delivery Periods, Delays, Neglect of Duty and Acts of God 1. The Customer must take acceptance of delivered items – even those which are defective.
1. In the absence of any contractual agreements to the contrary, agreed delivery deadlines Where he refuses to do so indicating the alleged defects, he shall not be entitled to derive
shall be deemed as observed when, by this time, the delivery item left our works, was handed claims for damages from his inability to use the said goods. He shall also bear the risk of
over to the forwarding agent at our works or was indicated ready for dispatch to the Customer. further deterioration in this respect. His rights in the event of defects shall remain unaffected
2. Where fulfilment of the order depends on documents and permits being furnished or essen- by this. Acceptance of the delivered items shall not be subject here to an acceptance of goods
tial questions being clarified by the Customer, any delivery deadline consented to or agreed pursuant to § 640 of the German Civil Code - BGB). 2. Where delivered items are taken into
upon by us shall only remain binding once the Customer has clarified the said question or fur- operation without any reservations, this shall be deemed as an acceptance regardless of
nished the said documents or permits by the start of the 10th week prior to the delivery dead- whether consignments or other services, in particular assembly, are yet to be effected by us.
line. What documents and clarifications are to be furnished in the context of this stipulation 3. In case of our exceptional voluntary agreement given in advance and in writing without
shall depend on the separate provisions of both Parties to the Contract or shall result from the implying any acceptance of a statutory duty, to partially or completely accept goods returned
nature of the Contract. 3. In the absence of agreements to the contrary, delivery periods shall to us, the following applies: Only goods returned in a faultless technical and optical condition
commence once the order confirmation has been sent. 4. Delivery periods shall, however, not coming in their original packing, in complete packing units, and without any missing items, will
commence until the Customer has furnished the required documents and permits and has be accepted by us. The original Bill of Delivery must be included in the return shipment, which
clarified those questions essential for the implementation of the Contract. What documents has to be sent by the purchaser to us free of postage and handling. After corresponding receipt
and permits are to be furnished and what questions are to be clarified by the Customer shall of the goods, the customer then receives a goods credit note less the costs of putting back into
be determined by the individual contractual agreements made by the Parties or by the nature storage, which depend on the value of the goods returned. In the case of a goods value of <
of the Contract itself. 5. Observance of the delivery period shall depend on the Customer ful- 300 € the fee for putting back into storage is 30 %, 20 % for a goods value of > 300 € to < 600
filling his agreed advance payment obligations. Beyond this, the delivery period shall likewise €; 15 % for a goods value > 600 € to <1,000 €; 10 % from a goods value of > 1,000 €. However,
commence on fulfilment of those contractual obligations of the Customer which are laid down returned goods are only accepted by us in any case and are offset against a credit note, if a
maximum of 6 months has passed between the date of the delivery note of the original delivery
2017 613
General terms of sale
and the date of the return of goods. However, we will in any case only accept goods returns particular transport costs, tolls, work and material costs - where the outlay is increased as a
and issue a goods credit note if the period between the date of the delivery note and the date result of transferring the goods to be delivered to location other than the delivery address,
of the goods return does not exceed 6 months. Hazardous items and goods with a limited shelf unless transfer occurs in accordance with the usage set out in the Contract. 6. Claims under
life are excluded from returns. the right of recourse on the part of the Customer in the case of the purchase of consumer
§ 9 Terms of Payment goods (§ 478 of the German Civil Code - BGB) shall be excluded in this respect when relating
1. Our invoices are payable with a 2 % discount within 10 days of the invoice date or 30 days to agreements made by the Customer with his buyer going beyond the legal claims for defects
net, departing from the net value of the goods (as per payment received date). 2. We shall of that buyer. The Customer must inform us in good time of any claims for defects lodged by
only accept means of payment going beyond cash or transfers to those accounts indicated his buyer so that we are in a position to meet the claims of the buyer instead of the Customer
on the invoices for the sake of fulfilling the Contract – this shall particularly apply in the case if we so wish. 7. Where our contractual obligations also include assembly of the items to be
of bills of exchange or cheques. All payments must be effected free of charge to us. Bank, delivered, an acceptance certificate must be produced once assembly has been completed
discount and collection charges shall be borne by the Customer. Payment by bill of exchange to be signed by the Customer. This must record any defects the Customer has become aware
shall be subject to prior agreement. Discount on payments by bill of exchange shall not be of or that have become apparent by this time. Where these defects are not recorded our
granted. The surrender of bills of exchange and cheques as such shall not be considered as services shall be deemed accepted free from defects in this respect. 8. Services rendered in
settlement of outstanding accounts. 3. In the event of culpable default on payment subsequent lieu and remedied defects shall be subject to the same warranty provisions governing the item
to the due date we can, without the need for any reminders, demand interest of 8 percentage originally delivered. 9. Claims for defects shall become statute-barred 1 year after the passing
points above the current base interest rate from the Customer as a contractual penalty. Where of the risk unless we are found to have caused the defect due to gross negligence or with pre-
we are in a position to prove greater delay-related damage, we shall be entitled to assert this meditation or to have concealed the defect with an intent to deceive. This shall apply for any
claim. As soon as those pre-conditions required to lodge a claim for compensation prevail, guarantees issued by us or binding to us in the absence of other agreements to the contrary.
our claims shall be regulated in accordance with § 11 of these General Terms of Business. 4. The statutory time-limits for claims lodged under the right of recourse pursuant to § 478 of the
The Customer shall neither be entitled to withhold any payments nor to set off any payment German Civil Code (BGB) shall remain unaffected by this. The same shall apply for longer
obligations in the event of counter claims being disputed, not recognised by us or not legally statutory time limitations, for the construction of buildings or for the delivery of goods used
enforceable. 5. Where the Customer defaults on payment for more than 10 days, where bills for a building in accordance with their normal purpose that have caused the building’s defec-
of exchange or cheques are not honoured punctually or where a substantial deterioration of tiveness. These time limitations shall also apply for consequential damage where the claims
the purchaser’s financial circumstances should come to our attention (regardless of whether are not asserted here based upon an illegal act. Where a defective delivery shall make defect
this occurred prior or subsequent to conclusion of the Contract), we shall have the option of remediation necessary, the time limitation shall only be suspended for such time as defects
demanding either a) advance payment on all those services not yet provided (including bills have been remedied and shall not be reinstated again. 10. Before the Customer can assert
receivable) or b) the provision of collateral in respect of these claims. For such time as these any further claims or rights (cancellation, price reductions, compensation or reimbursement of
claims remain unfulfilled we shall not be obliged to effect further deliveries arising from current expenses) we shall have the opportunity to be set an appropriate deadline in which to remedy
contracts. 6. Each part delivery shall be considered a separate transaction. 7. Part payments the defect where we have not issued any guarantee worded to the contrary. Where we fail
are subject to special written agreement. to remedy the defect despite at least two attempts, where we refuse to remedy the defect or
where this remediation is not possible or not reasonable to the Customer, the Customer shall
§ 10 Retention of Title be entitled to cancel the Contract or to lower (reduce) remuneration. § 13 of these terms shall
1. We shall retain title of ownership on the delivered items until such time as the Customer apply for the assertion of claims for compensation or reimbursement of expenses. 11. The
has paid all claims arising from his business relationship with us (extended retention of title to following shall also apply in the event of claims based upon deficiencies in title: In the absence
ownership). Thus, this retention of title on the delivered items also safeguards claims lodged of provisions to the contrary we shall merely be obliged to effect delivery in the country of
against the Customer arising from contracts not relating to the delivered items. The Customer the delivery address unaffected by third party rights. In the event of us being responsible for
shall secure ownership by way of security for us. 2. Where the extended retention of title to violating third party copyrights we shall be entitled to either acquire at our own expense a right
ownership has not become part of the Contract due to the Customer having conflicting General of exploitation sufficient for the agreed or precluded use and make this over to the Customer,
Terms of Business, delivery based upon ordinary retention of title can be used as an alternati- to change the delivered goods in such a way as to ensure the copyright is not violated or to
ve. 3. The Customer may only sell the delivered items in ordinary business transactions where exchange the delivered goods insofar as the agreed and precluded use is not compromised.
he is not in default of payment and where he has not suspended payments. In such cases Where we are unable to do this, where we refuse to remedy the defect or where this fails,
resale shall not be permitted. 4. On concluding the purchase contract with us the Customer the Customer shall be entitled to lodge legal claims and assert his rights. § 13 of these terms
shall, by way of collateral, already assign to us the claims he would be entitled to against his shall apply for the assertion of claims for compensation or reimbursement of expenses. 12.
buyer on the basis of the sale or any other legal reason with respect to the subject of the Where the Customer chooses to cancel the Contract on the basis of deficiencies in title or a
Contract along with all secondary rights, at an amount corresponding to the percentage value quality defect subsequent to a failure to remedy these, he shall also forfeit his right to claim for
of the subject of our Contract. The Customer shall be entitled to collect the claim as long as compensation for the defect. Where the Customer chooses to claim damages subsequent to
he does not default on his payments to us or has not suspended payments generally. 5. The a failure to remedy defects, the goods shall remain at the Customer’s premises insofar as this
Customer must immediately inform us in writing of any attachments, seizures or other disposi- is reasonable to him. Compensation shall be limited to the difference between the price to the
tions by third parties on the item subject to retention of title and enclose all relevant documents Customer and the value of the defective goods. This shall not apply where we have caused the
(fieri feci etc.). Where a third party is unable to reimburse us the judicial and extra-judicial costs contractual violation with an intent to deceive. 13. Where a selection of samples is sent out to
of an action pursuant to § 771 of the German Code of Civil Procedure (ZPO), the Customer the Customer for inspection, we shall only be responsible for ensuring the delivery is effected
shall be held liable to cover this shortfall incurred by us. 6. We can demand that the Customer in accordance with the sample selection taking any adjustments into account. 14. Where the
makes notification of the assignment to his buyers and that he furnishes us with all informa- Customer receives erroneous assembly instructions, we shall merely be obliged to deliver
tion and documents necessary to collect the assigned claims. 7. Where those Customer’s assembly instructions free from errors and indeed only at all when the error in the assembly
claims - arising from resale of the goods subject to our retention of title or from the resale of instructions is at variance with proper assembly.
goods of which we are co-owners - are incorporated into a current account, the Customer
must immediately assign his payment claim to us to the value of the current and recognised § 13 Compensation/Reimbursement of Expenses
balance – i.e. to the amount of our claims against the Customer. 8. The Customer shall be 1. The purchaser’s legal right of rescission – with the exception of cases that fall within §12 and
obliged, for as long as title is retained, to treat the goods with care and to keep them in proper §13 – shall be neither excluded nor limited. Likewise it is not intended to exclude or limit any
condition. Any necessary repairs must be performed immediately by us – with the exception of legal or contractual rights or claims to which we may be entitled. 2. We shall be liable without
emergencies – at the Customer’s cost. We shall bear the cost of these repairs where we are limit for intentional harm and gross negligence (including that of our legal representatives or
obliged to provide services in lieu or remedy defects as part of the provisions laid down in these agents) and for injury to life, limb or health. We shall also have unlimited liability in providing
General Terms of Business relating to warranties. 9. We shall be entitled, at the Customer’s guarantees if a defect that is covered by a guarantee triggers liability. There shall also be no
cost, to sufficiently insure - to reinstatement value - those goods subject to retention of title limit to our liability in relation to offences relating to the creation of a hazard, particularly in
against theft and damage of all kinds, in particular fire or water damage where the Customer accordance with the German Product Liability Act (Produkthaftungsgesetz). This shall not
fails to prove he has taken insurance cover of this kind. 10. Where the realisable value of that affect any liability under the recourse principles under §478 et seq. of the German Civil Code
collateral to which we are entitled shall exceed by more than 15 % the claims to be safeguarded (BGB).
arising from this business relationship, we shall be obliged, upon the Customer’s request, to 3. In the case of any other culpable breach of significant contractual duties (cardinal duties,
release the collateral in this respect. The choice of collateral to be released shall fall to us. 11. subclause 8) our remaining liability shall be limited to foreseeable damage as is usual for this
The processing and transformation of the delivered items by the Customer shall always be type of contract. 4. All other forms of liability shall be excluded from this contract regardless of
performed for us. Where the delivered items are processed along with items not belonging to their legal grounds, in particular claims resulting from a breach of any main or ancillary duties
us we shall acquire co-ownership of the new item corresponding to the value of the delivered under the contract, illegal acts and any other tortious acts. 5. The same exclusions, limitations
item in relation to the other items processed at the time of processing. The items arising from and exceptions shall apply in respect of claims based on fault at the time the contract was
processing shall be subject to the same provisions as the items delivered subject to retention of concluded. 6. §13 shall apply analogously in the case of any reimbursement of expenses (with
title. 12. Where the goods subject to retention of title are connected to a plot of land of which the the exception of any reimbursement of expenses in accordance with §439 II or §635 II of the
goods form an essential part, the Customer shall be obliged to allow us to view this plot of land German Civil Code (BGB)). 7. Any exclusion or limitation of our liability shall also apply to our
and have access to it and shall be obliged to assign to us his claims in respect of the owners legal representatives and agents. 8. No reversal of the burden of proof is intended. Cardinal
of the land or to grant other collateral securities of equal value should he be the owner of the duties are significant duties, i.e. such duties which characterise the contract and on which the
land himself. Should a substantial deterioration of the financial circumstances of the Customer contractual partner can rely; these are therefore the significant rights and duties which are the
occur we shall be entitled, with the consent of the owner of the land or the landlord, to step into prerequisites for contractual performance and which are indispensible in order to fulfil the con-
the legal position of the Customer vis-à-vis the former. 13. The assertion of our claims arising tractual purpose. 9. Statutory limitation of claims between the Supplier and the Customer shall
from ownership by way of security shall not mean cancellation of the Contract. be governed by § 12, Section 9 insofar as claims relating to product liability pursuant to § 823
§ 11 Delay of the Customer et seq. of the German Civil Code (BGB) or the Product Liability Law are not affected by this.
1. Where the Customer fails to accept the goods on the agreed delivery deadline or once the This statutory limitation shall also particularly apply in the case of consequential damage. 10.
delivery period has come to an end, due to circumstances for which he is responsible, we We shall assume no liability for damage caused by unsuitable or improper use, defective com-
can demand compensation for the additional expenses we have incurred as a result. 2. In the missioning or assembly carried out by the Customer himself, natural wear and tear, defective
event of default by the Customer we shall be entitled, regardless of the possibility of asserting or negligent treatment – in particular through excessive use, unsuitable operating resources,
a greater claim for actual damage, to demand interest on the sum for which the Customer is in replacement materials, defective construction work, unsuitable ground for building, chemical,
default at 8 percentage points above the current base interest rate. 3. Where we are entitled electrochemical or electrical influences and improper modifications or maintenance performed
to claim damages instead of performance we can, regardless of the possibility of asserting a without our approval. 11. We shall not be responsible for issuing any special public permits
greater claim for actual damage, demand 15 % of our price as damages provided the Customer required or for the observance of any pollution protection laws. This shall not apply where the
fails to prove that there was no damage caused at all or damage is considerably lower than observance of these laws or the provision of special public permits have been agreed upon by
the lumpsum compensation. us on an individual contractual basis.
§ 12 Claims for Defects § 14 Court of Jurisdiction and Place of Fulfilment
1. Where defective goods exist for which we are responsible we shall be entitled to either 1. The place of fulfilment for all contractual obligations shall be 87772 Pfaffenhausen. 2.
remedy the defect or to effect subsequent deliveries. Any replaced component shall transfer Where the Customer is a merchant, a legal entity under public law or a special public fund, we
to our ownership. 2. The assertion of claims for defects by the commercial Customer shall be shall be entitled to make the court of jurisdiction for all litigation arising from this contractual
dependent on the latter having fulfilled his due obligations in terms of examining the goods and relationship alternatively Memmingen, the Customer’s place of business or – in the case of
giving notice of any defects pursuant to § 377 of the German Commercial Code (HGB). Any foreign deliveries – the capital of the country where the Customer has his place of business.
notification of defects must be made in writing detailing the specific defect involved. 3. We can The same shall apply where the domicile or place of habitual residence of the Customer at the
refuse to remedy the defects for such time as the Customer has failed to fulfil all his payment time the action commences is not known. This shall also apply for litigation arising from bills
obligations, with the exception of a sum corresponding to the price reduction on the defective of exchange and cheques. 3. Legal relationships between the Customer and ourselves shall
goods. In this case, the Customer shall only be obliged to effect advance payment where we be subject only to the law of the Federal Republic of Germany excluding the UN convention on
have confirmed our liability for defects within the ambit of these General Terms of Business to the international sale of goods.
him in writing. 4. We must be given the opportunity to inspect the notified defects on the spot. § 15 Others
This inspection must be performed by us without delay where the Customer is interested in 1. We process your personal data for the execution of your order and to provide you with the
immediate settlement of the matter. Claims for defects shall not be permitted where merely latest news about our range of products. You may object to the processing and use of your data
insignificant deviations from the properties of the goods or where merely an insignificant for advertising purposes at any time (e-mail to marketing@raico.de).
impairment of the serviceability of the goods shall prevail. 5. We can demand from the Custo- (Dated march 2017)
mer those additional costs incurred for the purpose of subsequent fulfilment of obligations - in
614 2017
Notes
2017 615
Notes
616 2017
Notes
2017 617
Pictures and diagrams, measurements, and technical
data in this catalogue have been used for illustrating
purposes, and are thus not binding. We reserve the
right to make changes to reflect technical advance-
ments.
618 2017
No. 002405 – Release 04/2017; Cover photo: Cineplex – Baden-Baden, DE; Foto: Hopermann Fotodesign