Lab report
electrical energy
Gas valve: A valve that controls fuel flow to the burner in a gas-fired furnace or heater.
Primary limit switch: Furnace safety switch, a normally closed switch that opens if it gets too hot,
Secondary limit switch is use for down flo furnace in case the primary fails
To light the burner Turn you thermostat to 80 degrees or to a setting that will demand
heat. Make sure the thermostat is in "Heat" mode. Then turn the knob on the gas valve to the
pilot position press the igniter button on the side of the gas valve which will energize the
pilot solenoid allowing gas to flow to the pilot after mins turn the knob to the on position
and release the button , the thermocouple will turn the heat energy into electrical energy
usually
about 20 millivolts the the gas valve solenoid is energize the will open the gas valve
allowing gas to flow to the burner
Electrical sequence of operation in the upflo the thermostat is turned to the heating mode at
above room temperature , the thermostat close which energize the primary limit switch which
energize the gas valve, which energize the primary of the transformer when the secondary of the
transformer is energized after 60 seconds the fan limit close and energize the blower motor
Electrical sequence of operation in the downflo the thermostat is turned to the heating mode at
above room temperature , the thermostat close which energize the primary and secoundary limit
switch at the same time energizing the transformer which energize the gas valve, after 20
seconds the fan limit close and energize the blower motor
Pilot is on
Burner is off
Use ohm meter across fan limit got a reading of 120 v which mean the fan limit switch is open
Time 15 mins
FAULT NO 3
SET THEMOSTAT
Fan auto
Pilot is on
Burner is on
Observation
Check the fan limit use the volt meter got 0v across the fan limit which indicates the fan limit is
stuck close
Time 15mins
Pilot is on
Burner is off
Conclusion solenoid can’t lift the plunger to allow gas to flow to the main burner
Time 20 mins
Fault no 17 no heat
Fan auto
Pilot is on
Burner is off
Try lighting the pilot for several min did not light
Use the ohm meter to check the millivolts across the thermocouple 20milv
Time 20mins
Down flo
Pilot is on
Burner is off
Blower is energized
Used volt meter on the high limit thermostat 0v indicating its closed
Use thermometer across the vent there was a small temperature difference
Fault no 6
NO HEAT
FAN AUTO
Pilot is OFF
Burner is on
Blower is off
Primary 0v
Secondary 0v