LIGHT COMMERCIAL AIR CONDITION

PRODUCT CONCEPT

Cassette
Compact / Slim Design
Reduce the height of the indoor unit, less space requiring in installation.

Model Dimension(D*W*H)
12-18K 570*570*260
24K 840*840*205
24K-45K 840*840*245
55K 840*840*287
CDU for 12-24K

A3 Cassette 12-18K
CDU for 30K-45K

Slim Cassette 24K-55K


CDU for 55K
Standard Features

Reserved Air Outlet For Duct

Reserves the space for air outlet from the side of indoor unit;
It’s available to connect air duct from side to small rooms nearby.

360°Air Flow Panel

Ensure a uniform temperature distribution across the room


without dead corners.
Standard Features

Build-in Drain Pump

The drain pump can lift the condensing water up to 750mm upmost.
It’s convenient to install drainage piping under most space condition.

Easy maintained Drain Pump

Improved structure makes it more convenient to repair the


drain pump.

Draining Pump
Standard Features

Reserved remote on-off and alarm ports

Remote on-off: With the reserved ports. a remote switch can be easily
connected to realize remote control.
Alarm: The built-in PCB can output alarm signal, which achieve setting
up an external alarm light or vibration gauge possible.

Fresh Air Intake

A ventilation motor (no more than 200W) can be installed in fresh air
duct and works with indoor fan to increase the volume of fresh air.
TECHNICAL SPECIFICATION
Fix Speed Cassette
Indoor unit customer model 42QTD012FSA 42KTD018FS 42KTD024FS 42KTD030FS 42KTD036FS 42KTD045FS 42KTD055FS
Outdoor unit customer model 38QUS012FSA 38KUS018FS19 38KUS024FS 38KUS030FS 38KUS036FS18 38KUS045FST 38KUS055FSA
1Ph- 1Ph-
1Ph- 220~240V- 1Ph- 220~240V- 3Ph- 380~415V- 3Ph- 380~415V- 3Ph- 380~415V-
Power supply Ph-V-Hz 220~240V- 220~240V-
50Hz 50Hz 50Hz 50Hz 50Hz
50Hz 50Hz
Power supply from Indoor Indoor Indoor Indoor Indoor Indoor Indoor
Capacity Btu/h 12000 18000 25000 32000 36000 45000 52000
Cooling Input W 1095 1900 2500 3200 3550 5300 6200
(Rating
performance) Current A 4.8 9.5 12.5 15.8 8.2 8.5 10.5
EER W/W 3.2 2.8 2.9 2.9 3.0 2.5 2.5
Rated(Max) input consumption W 1650 2700 3700 4900 5350 6600 8500
Rated(Max) current A 8 15.5 18.0 23.0 11.0 12.0 13.0
Indoor air flow (High/Mid/Low) m3/h 620/510/410 700/550/450 1060/920/760 1800/1500/1300 1800/1500/1300 1700/1470/1270 1890/1470/1280
Indoor noise level (High/Mid/Low) dB(A) 42/38/34 46/39/36 48/44/39 53/50/47 53/50/47 53/50/47 54/50/47
Dimension(W*D*H) mm 570x570x260 570x570x260 840x840x205 840x840x245 840x840x245 840x840x245 840x840x287
Indoor unit Packing (W*D*H) mm 655x655x290 655x655x290 900x900x217 900x900x257 900x900x257 900x900x257 900x900x292
Net/Gross weight Kg 14.5/17.5 16.5/19.5 22.5/25.5 25.0/28.5 25.0/25.5 27.0/30.5 29.0/34.0
Outdoor noise level dB(A) 57 57 61 63 63 64 63
Dimension(W*D*H) mm 770x300x555 770x300x555 845x363x702 946x410x810 946x410x810 946x410x810 900x350x1170
Outdoor unit Packing (W*D*H) mm 900x348x625 900x348x625 965x395x765 1090x500x875 1090x500x875 1090x500x875 1032x443x1307
Net/Gross weight Kg 32.1/34.5 35.8/38.6 49.0/52.5 63.0/68.5 68.5/73.0 81.5/86.5 92.7/104.2
Refrigerant (R410A) g 1000 1000 1400 2500 2400 2300 3100
Design pressure Mpa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5
mm Φ6.35/Φ Φ6.35/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ
Liquid side/ Gas side
(inch) 12.7(1/4"/1/2") 12.7(1/4"/1/2") 15.9(3/8"/5/8") 19(3/8"/3/4") 19(3/8"/3/4") 19(3/8"/3/4") 19(3/8"/3/4")
Refrigerant
piping Max. pipe length m 15 25 25 30 30 50 50
Max. difference in level m 8 15 15 20 20 30 30
Controller (Optional) Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired
Operation temperature ℃ 17~30 17~30 17~30 17~30 17~30 17~30 17~30

Ambient Indoor(cooling/heating) ℃ 17~32 17~32 17~32 17~32 17~32 17~32 17~32


temperature Outdoor(cooling/heating) ℃ 18-43 18-43 18-43 18-43 18-43 18~43 18~43
Application area m2 16~23 24~35 33~49 43~62 48~70 60~88 69~101

* *
Note: All features and specifications are subject to change without prior
notice for product improvement purposes. (* means optional )
The golden fin is basic for the 38QUS012FSA only.
TECHNICAL SPECIFICATION
Inverter Cassette
Indoor unit customer model 42QTD012VS 42QTD018VSG 42QTD024VSA 42QTD030VS 42QTD036VS 42QTD045VS 42QTD055VS
Outdoor unit customer model 38QUS012VS 38QUS018VSG 38QUS024VSA 38QUS030VS 38QUS036VS 38QUS045VS 38QUS055VS
1Ph- 220~240V- 1Ph- 220~240V- 1Ph- 220~240V- 1Ph- 220~240V- 3Ph- 380~415V- 3Ph- 380~415V- 3Ph- 380~415V-
Power supply Ph-V-Hz
50Hz 50Hz 50Hz 50Hz 50Hz 50Hz 50Hz
Power supply from Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor
12000 18000 24000 30000 36000 45000 55000
Capacity Btu/h
(3000-14000) (8000-19000) (9000-26000) (11000-31000) (11000-36000) (19000-45000) (25000-55000)
Cooling 1100 1700 2340 2800 3900 5500 6500
(Rating Input W
(200-1500) (720-1960) (800-2800) (1000-3200) (1000-3900) (1500-5500) (2000-6700)
performance) Current A 4.8 7.5 10.5 12.4 6.6 9.0 10.2
EER W/W 3.2 3.1 3.0 3.1 2.7 2.4 2.5
14000 19000 26000 32000 38000 50000 58000
Capacity Btu/h
(3000-15000) (8000-21000) (9000-29000) (13000-33000) (13000-38000) (21000-52000) (28000-60000)
Heating 1060 1600 2115 2400 3400 4600 5300
(Rating Input W
(300-1360) (700-1870) (800-2800) (1000-3000) (1000-3500) (1500-5600) (2000-6300)
performance) Current A 4.7 8.3 9.6 11.5 5.7 7.7 10.0
COP W/W 3.9 3.5 3.6 3.9 3.3 3.2 3.2
Rated(Max) input consumption W 1900 2950 2950 3400 4150 6700 7800
Rated(Max) current A 9.0 13.5 14.0 19.0 10.0 13.0 16.0
Indoor air flow (High/Mid/Low) m3/h 620/500/420 720/620/540 1350/1200/1070 1560/1400/1200 1800/1500/1300 1800/1500/1300 1970/1500/1300
Indoor noise level (High/Mid/Low) dB(A) 44/39/36 44/39/36 47/44/42 51/49/46 53/50/47 53/50/47 54/50/47
Dimension(W*D*H) mm 570x570x260 570x570x260 840x840x245 840x840x245 840x840x245 840x840x245 840x840x287
Indoor unit Packing (W*D*H) mm 662x662x317 662x662x317 900x900x265 900x900x265 900x900x265 900x900x265 900x900x307
Net/Gross weight Kg 16.2/21.4 16.2/21.4 24.1/27.9 26.5/30.5 24.5/29.0 26.7/31.1 29.3/33.3
Outdoor noise level dB(A) 57 57 61 62 63 63 64
Dimension(W*D*H) mm 800x333x554 800x333x554 845x363x702 946x410x810 946x410x810 946x410x810 952x415x1333
Outdoor unit Packing (W*D*H) mm 920x390x625 920x390x625 965x395x775 1090x500x885 1090x500x875 1090x500x875 1095x495x1480
Net/Gross weight Kg 29.9/32.6 34.5/37.2 49/51.5 63.0/68.5 67.3/73.1 74.3/79.9 97/107
Refrigerant (R410A) g 1050 1350 1950 2800 3000 3650 4000
Design pressure Mpa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5
mm Φ6.35/Φ Φ6.35/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ
Liquid side/ Gas side
Refrigerant (inch) 9.52(1/4"/3/8") 12.7(1/4"/1/2") 15.9(3/8"/5/8") 15.9(3/8"/5/8") 19(3/8"/3/4") 19(3/8"/3/4") 19(3/8"/3/4")
piping Max. pipe length m 15 25 25 30 30 50 50
Max. difference in level m 8 15 15 20 20 30 30
Controller (Optional) Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired
Operation temperature ℃ 17~30 17~30 17~30 17~30 17~30 17~30 17~30
Ambient Indoor(cooling/heating) ℃ 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30
temperature Outdoor(cooling/heating) ℃ 0~50/-15~24 0~50/-15~24 0~50/-15~24 0~50/-15~24 0~50/-15~24 0~50/-15~24 0~50/-15~24
Application area m2 16~23 24~35 33~49 40~58 48~70 60~88 73~107

*
Note: All features and specifications are subject to change without prior
notice for product improvement purposes. (* means optional )
PRODUCT CONCEPT

Console
Ultra-thin and ultra-light design of indoor units.

IDU for 12K CDU for 12-24K

IDU for 18-24K CDU for 30K-45K

IDU for 30K-55K CDU for 55K


Standard Features

Style Installation

Fashionable design and streamline appearance, suitable for different


styles room.
Ceiling installation saves room space;
Floor installation helps prevent losing warm air.

Ceiling installation Floor installation

3D Air Flow

Vertical air flow and horizontal air flow can be adjusted by remote
controller;
Fulfill the optimum air organization, more comfortable.
Standard Features

3-way Pipe Direction

The connection pipe can be put into the unit from bottom, side or rear,
which makes installation much easier.

2-way Drainage

Both right side and left side drainage holes are available to avoid the
space limitation for drainage pipe installation.
Standard Features

Universal Spare Parts

More than 60% parts and assemblies (such as fan wheel, plastic cases,
metal parts and etc.) are universal for 3 different bodies, which makes
the production and maintenance much easier.

Louver Position Memory

When you start the unit next time, the angle of the horizontal louver will
automatically move to the same position as you set last time.
TECHNICAL SPECIFICATION
Fix Speed Console
Indoor unit customer model 42QZL018FS 42KZL024FS 42KZL036FS 42KZL045FS 42KZL055FS
Outdoor unit customer model 38QUS018FS 38KUS024FS 38KUS036FS18 38KUS045FST 38KUS055FSA
1Ph- 220~240V- 1Ph- 220~240V- 3Ph- 380~415V- 3Ph- 380~415V- 3Ph- 380~415V-
Power supply Ph-V-Hz
50Hz 50Hz 50Hz 50Hz 50Hz
Power supply from Indoor Indoor Indoor Indoor Indoor

Capacity Btu/h 18500 26000 36000 48000 53000


Cooling Input W 2110 2700 3700 5000 6100
(Rating
performance) Current A 9.3 12.7 8.2 8.7 10.3

EER W/W 2.6 2.8 2.9 2.8 2.5

Rated(Max) input consumption kW 2950 3700 5350 6600 8500

Rated(Max) current A 15.0 18.0 11.0 12.0 13.0


3
Indoor air flow (High/Mid/Low) m /h 1200/930/770 1200/930/770 1800/1500/1300 2170/1860/1660 2170/1860/1660

Indoor noise level (High/Mid/Low) dB(A) 52/47/44 52/47/44 55/51/47 56/52/49 56/52/49

Dimension(W*D*H) mm 1068x675x235 1068x675x235 1285x675x235 1650x675x235 1650x675x235

Indoor unit Packing (W*D*H) mm 1145x755x318 1145x755x318 1360x755x318 1725x755x318 1725x755x318

Net/Gross weight Kg 24.0/29.0 24.0/29.0 29.1/34.6 39.0/45.0 41.0/48.0

Outdoor noise level dB(A) 58 61 63 64 63

Dimension(W*D*H) mm 770x300x555 845x363x702 946x410x810 946x410x810 900x350x1170

Outdoor unit Packing (W*D*H) mm 900x348x625 965x395x775 1090x500x875 1090x500x875 1032x443x1307

Net/Gross weight Kg 36.5/39.7 51.0/54.5 68.3/72.9 81.5/86.5 92.7/104.2

Refrigerant (R410A) g 1500 1400 2400 2300 3100

Design pressure Mpa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5

mm Φ6.35/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ


Liquid side/ Gas side
(inch) 12.7(1/4"/1/2") 15.9(3/8"/5/8") 19(3/8"/3/4") 19(3/8"/3/4") 19(3/8"/3/4")
Refrigerant
piping Max. pipe length m 25 25 30 50 50

Max. difference in level m 15 15 20 30 30

Controller (Optional) Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired

Operation temperature ℃ 17~30 17~30 17~30 17~30 17~30

Ambient Indoor(cooling/heating) ℃ 17~32 17~32 17~32 17~32 17~32


temperature Outdoor(cooling/heating) ℃ 18-43 18-43 18-43 18-43 18~43
2
Application area m 25~36 35~51 48~70 64~94 71~103

* *
Note: All features and specifications are subject to change without prior
notice for product improvement purposes. (* means optional )
The golden fin is basic for the 38QZL018FS only.
TECHNICAL SPECIFICATION
Inverter Console
Indoor unit customer model 42QZL012VS 42QZL018VSG 42QZL024VSA 42QZL036VS 42QZL045VS 42QZL055VS
Outdoor unit customer model 38QUS012VS 38QUS018VSG 38QUS024VSA 38QUS036VS 38QUS045VS 38QUS055VS
1Ph- 220~240V- 1Ph- 220~240V- 1Ph- 220~240V- 3Ph- 380~415V- 3Ph- 380~415V- 3Ph- 380~415V-
Power supply Ph-V-Hz
50Hz 50Hz 50Hz 50Hz 50Hz 50Hz

Power supply from Outdoor Outdoor Outdoor Outdoor Outdoor Outdoor


12000 18000 24000 36000 46000 55000
Capacity Btu/h
(3000-13000) (8000-19000) (11800~26000) (11000-36000) (19000-47000) (25000-55000)
Cooling 1210 1650 2340 3900 5400 6500
(Rating Input W
(200-1800) (720-1800) (740~2930) (1000-3900) (1500-5600) (2000-6900)
performance) Current A 5.5 7.3 10.0 6.3 9.1 10.6
EER W/W 2.9 3.2 3.0 2.7 2.5 2.5
13000 19000 24000 37000 50000 58000
Capacity Btu/h
(3000-15000) (8000-20000) (12000~26800) (13000-38000) (21000-54000) (28000-60000)
Heating 1100 1500 2050 3050 4300 5300
(Rating Input W
(300-1460) (510-1530) (650~ 2850) (1000-3300) (1500-5400) (2000-5800)
performance) Current A 4.8 6.6 10 5.5 7.7 10.0
COP W/W 3.5 3.7 4 3.6 3.4 3.2
Rated(Max) input consumption kW 1900 2950 2950 4150 6700 7800
Rated(Max) current A 9.0 13.5 14.0 10.0 13.0 16.0
3
Indoor air flow (High/Mid/Low) m /h 510/480/370 880/760/650 1208/1066/853 1800/1500/1300 2170/1860/1660 2170/1860/1660
Indoor noise level (High/Mid/Low) dB(A) 44/42/36 43/39/35 54/48/42 55/51/47 56/52/49 56/52/49
Dimension(W*D*H) mm 700x600x210 1068x675x235 1068x675x235 1285x675x235 1650x675x235 1650x675x235
Indoor unit Packing (W*D*H) mm 810x710x310 1145x755x318 1145x755x318 1145x755x318 1725x755x318 1725x755x318
Net/Gross weight Kg 14.8/19.0 28.0/33.3 26.8/31.9 31.0/36.5 37.5/43.8 40.0/46.0
Outdoor noise level dB(A) 57 57 61 63 63 64
Dimension(W*D*H) mm 800x333x554 800x333x554 845x363x702 946x410x810 946x410x810 952x415x1333
Outdoor unit Packing (W*D*H) mm 920x390x625 920x390x625 965x395x775 1090x500x875 1090x500x875 1095x495x1480
Net/Gross weight Kg 29.9/32.6 34.5/37.2 49/51.5 67.3/73.1 74.3/79.9 97.0/107.0
Refrigerant (R410A) g 1050 1350 1950 3000 3650 4000
Design pressure Mpa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5
Φ6.35/Φ Φ6.35/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ
Liquid side/ Gas side mm(inch)
Refrigerant 9.52(1/4"/3/8") 12.7(1/4"/1/2") 15.9(3/8"/5/8") 19(3/8"/3/4") 19(3/8"/3/4") 19(3/8"/3/4")
piping Max. pipe length m 15 25 25 30 50 50
Max. difference in level m 8 15 15 20 30 30
Controller Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired
Operation temperature ℃ 17~30 17~30 17~30 17~30 17~30 17~30
Ambient Indoor(cooling/heating) ℃ 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30
temperature Outdoor(cooling/heating) ℃ 0~50/-15~24 0~50/-15~24 0~50/-15~24 0~50/-15~24 0~50/-15~24 0~50/-15~24
Application area m2 16-23 24~35 33~49 48-70 61-90 73-107

*
Note: All features and specifications are subject to change without prior
notice for product improvement purposes. (* means optional )
PRODUCT CONCEPT

Duct
Slim Body, Concealed Installation.

CDU for 9-24K

IDU for 9-55K CDU for 36K-45K

CDU for 45-55K


Standard Features

Concealed Installation

Concealed installation, harmonize with indoor decoration.

Slim design

The industry Lowest height is designed to be fitted into tight roof spaces.
*18K unit - 210mm, 24K/36K unit - 249mm, 45K/55K unit -300mm

270
(Before)

249
(now)
Standard Features

Easy Installation

The frame size of air inlet in rear and bottom is the same. It’s very easy
to switch to match different application.

Top middle Static-Pressure

The maximum static pressure reaches 160 Pa.


As a ducted air conditioner with medium static pressure, it has the
widest static pressure range.
Standard Features

Easy Clean

It is easy to draw out the filter from the indoor unit for cleaning.

With a larger window design, once the motor and the blower
wheels have been detached, heat exchanger and water receiver
tray in behind can be seen very clearly. Dust can be easily removed
from the inside by vacuum.
Standard Features

Easy maintenance

A6 duct allows operators maintenance the motor from the bottom


more easily compare with that on the top.

A6 duct has big space for maintenance at the side.


Optional Features

Built-in drain pump (optional)

Built-in drain pump can lift the water up to 750mm height, which
widens the drainage piping range.

Constant air volume control (Full DC model)

With constant air volume control technology, the duct will


automatically adjusts to perfect static pressure and keep constant air
volume.
TECHNICAL SPECIFICATION
Fix Speed Duct
Indoor unit customer model 42QSB018FS 42QSB024FS 42QSB036FS 42QSB045FS 42QSB055FS
Outdoor unit customer model 38QUS018FS 38QUS024FS 38QUS036FS 38QUS045FS 38QUS055FS
1Ph- 220~240V- 1Ph- 220~240V- 3Ph- 380~415V- 3Ph- 380~415V- 3Ph- 380~415V-
Power supply Ph-V-Hz
50Hz 50Hz 50Hz 50Hz 50Hz
Power supply from Indoor Indoor Outdoor Indoor Indoor
Capacity Btu/h 19000 26000 36000 48000 53000
Cooling Input W 2200 2870 3700 5350 6360
(Rating
performance) Current A 9.7 13.5 6.7 9.2 11.0
EER W/W 2.5 2.7 2.9 2.6 2.4
Capacity Btu/h 19000 28000 39000 55000 60000
Heating Input W 1750 2300 3700 4820 5540
(Rating
performance) Current A 7.9 11.3 6.7 8.3 9.3
COP W/W 3.18 3.31 3.46 3.35 3.17
Rated(Max) input consumption kW 2950 3700 4800 7200 7900
Rated(Max) current A 15.0 18.0 8.5 13.0 14.0
3
Indoor air flow (High/Mid/Low) m /h 980/810/730 1350/1170/960 1800/1350/1150 2200/1850/1400 2200/1850/1400
Indoor noise level (High/Mid/Low) dB(A) 49/45/43 48/45/43 50/44/41 53/48/42 53/48/42
ESP Range Pa 0-60 0-80 0-80 0-160 0-160
Dimension(W*D*H) mm 880x674x210 1100x774x249 1100x774x249 1200x874x300 1200x874x300
Indoor unit Packing (W*D*H) mm 1070x725x270 1305x805x305 1305x805x305 1405x915x355 1405x915x355
Net/Gross weight Kg 23.8/29.5 32.2/39.0 32.2/39.4 46.0/54.5 46.0/54.5
Outdoor noise level dB(A) 60 61 64 63 63
Dimension(W*D*H) mm 770x300x555 845x363x702 946x410x810 900x350x1170 900x350x1170
Outdoor unit Packing (W*D*H) mm 900x348x625 965x395x765 1090x500x875 1032x443x1307 1032x443x1307
Net/Gross weight Kg 36.5/39.7 52.7/56.1 74.4/78.9 97.0/107.0 97.0/107.0
Refrigerant (R410A) g 1500 1800 2850 3300 3200
Design pressure Mpa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5
mm Φ6.35/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ Φ9.52/Φ
Liquid side/ Gas side
Refrigerant (inch) 12.7(1/4"/1/2") 15.9(3/8"/5/8") 19(3/8"/3/4") 19(3/8"/3/4") 19(3/8"/3/4")
piping Max. pipe length m 25 25 30 50 50
Max. difference in level m 15 15 20 30 30
Controller (Optional) Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired
Operation temperature ℃ 17~30 17~30 17~30 17~30 17~30
Ambient Indoor(cooling/heating) ℃ 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30
temperature Outdoor(cooling/heating) ℃ 18~43/-7~24 18~43/-7~24 18~43/-7~24 18~43/-7~24 18~43/-7~24
Application area m2 25~37 35~51 48~70 64~94 71~103

Note: All features and specifications are subject to change without prior
notice for product improvement purposes. (* means optional )
TECHNICAL SPECIFICATION
Inverter duct (Full DC)
Indoor unit customer model 42QSB009VS 42QSB012VS 42QSB018VSG 42QSB024VSA 42QSB030VS
Outdoor unit customer model 38QSB009VS 38QSB012VS 38QUS018VSG 38QUS024VSA 38QUS030VS
1Ph- 220~240V- 1Ph- 220~240V- 1Ph- 220~240V- 1Ph- 220~240V- 1Ph- 220~240V-
Power supply Ph-V-Hz
50Hz 50Hz 50Hz 50Hz 50Hz
Power supply from Outdoor Outdoor Outdoor Outdoor Outdoor
9000 12000 18000 24000 31000
Capacity Btu/h
(1800-13900) (1800-13900) (8000-18250) (9000-26000) (11000-31000)
Cooling 910 1300 1650 2190 2930
(Rating Input W
(155-1698) (155-1698) (720-1800) (800-2800) (1000-3200)
performance) Current A 4.0 5.7 7.3 10.0 13.0
EER W/W 2.9 2.7 3.2 3.2 3.1
10000 13000 19000 24000 34000
Capacity Btu/h
(3400-15600) (3400-15600) (8000-21000) (9000~28190) (13000-34000)
Heating 860 1200 1450 1950 2350
(Rating Input W
(302-1330) (302-1330) (700-1750) (900~2600) (1000-3000)
performance) Current A 3.8 5.5 6.3 8.9 10.5
COP W/W 3.4 3.2 3.8 3.6 4.2
Rated(Max) input consumption W 1900 1900 2950 2950 3400
Rated(Max) current A 9.0 9.0 13.5 14.0 19.0
Indoor air flow (High/Mid/Low) m3/h 600/480/300 600/480/300 880/650/350 1250/1100/900 1540/1250/720
Indoor noise level (High/Mid/Low) dB(A) 40/35/27 40/35/27 44/39/35 42/40/38 53/49/46
ESP Range Pa 0-60 0-60 0-100 0-160 0-160
Dimension(W*D*H) mm 700x450x200 700x450x200 880x674x210 1100x774x249 1360x774x249
Indoor unit Packing (W*D*H) mm 860x540x285 860x540x285 1070x725x270 1305x805x305 1570x805x305
Net/Gross weight Kg 18.0/22.0 18.0/22.0 24.3/29.6 31.5/38.9 40.6/48.5
Outdoor noise level dB(A) 57 57 57 61 62
Dimension(W*D*H) mm 800x333x554 800x333x554 800x333x554 845x363x702 946x410x810
Outdoor unit Packing (W*D*H) mm 920x390x615 920x390x615 920x390x625 965x395x775 1090x500x875
Net/Gross weight Kg 29.9/32.6 29.9/32.6 34.5/37.2 49/51.5 62.9/68.5
Refrigerant (R410A) g 1050 1050 1350 1950 2800
Design pressure Mpa 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5 4.2/1.5
Φ6.35/Φ Φ6.35/Φ Φ6.35/Φ Φ9.52/Φ Φ9.52/Φ
Liquid side/ Gas side mm(inch)
Refrigerant 9.52(1/4"/3/8") 9.52(1/4"/3/8") 12.7(1/4"/1/2") 15.9(3/8"/5/8") 15.9(3/8"/5/8")
piping Max. pipe length m 15 15 25 25 30
Max. difference in level m 8 8 15 15 20
Controller Remote/Wired Remote/Wired Remote/Wired Remote/Wired Remote/Wired
Operation temperature ℃ 17~30 17~30 17~30 17~30 17~30
Ambient Indoor(cooling/heating) ℃ 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30 17~32/0~30
temperature Outdoor(cooling/heating) ℃ 0~50/-15~24 0~50/-15~24 0~50/-15~24 0~50/-15~24 0~50/-15~24
Application area m2 16-23 16-23 24-35 32-47 41-60

Note: All features and specifications are subject to change without prior
notice for product improvement purposes. (* means optional )
TECHNICAL SPECIFICATION
Inverter duct
Indoor unit customer model 42QSB036VS 42QSB045VS 42QSB055VS
Outdoor unit customer model 38QUS036VS 38QUS045VS 38QUS055VS
Power supply Ph-V-Hz 3Ph- 380~415V- 50Hz 3Ph- 380~415V- 50Hz 3Ph- 380~415V- 50Hz
Power supply from Outdoor Outdoor Outdoor
36000 46000 55000
Capacity Btu/h
(11000-36000) (19000-47000) (25000-55000)
Cooling 3900 5500 6800
(Rating Input W
(1000-3900) (1500-5700) (2000-7000)
performance) Current A 5.7 7.9 10.5
EER W/W 2.7 2.5 2.4
38000 51000 60000
Capacity Btu/h
(13000-39000) (21000-54000) (28000-62000)
Heating 3300 4100 5200
(Rating Input W
(1000-3400) (1500-5200) (2000-5600)
performance) Current A 4.7 6.2 8.2
COP W/W 3.4 3.6 3.4
Rated(Max) input consumption W 4150 6700 7800
Rated(Max) current A 10.0 13.0 16
Indoor air flow (High/Mid/Low) m3/h 1500/1100/900 2300/1850/1500 2300/1850/1500
Indoor noise level (High/Mid/Low) dB(A) 50/45/42 51/46/42 51/46/42
ESP Range Pa 0-80 0-160 0-160
Dimension(W*D*H) mm 1100x774x249 1200x874x300 1200x874x300
Indoor unit Packing (W*D*H) mm 1305x805x305 1405x915x355 1405x915x355
Net/Gross weight Kg 34.5/41.9 47.3/56.0 47.2/55.9
Outdoor noise level dB(A) 63 63 64
Dimension(W*D*H) mm 946x410x810 946x410x810 952x415x1333
Outdoor unit Packing (W*D*H) mm 1090x500x875 1090x500x875 1095x495x1480
Net/Gross weight Kg 67.3/73.1 74.3/79.9 97.0/107.0
Refrigerant (R410A) g 3000 3650 4000
Design pressure Mpa 4.2/1.5 4.2/1.5 4.2/1.5
Liquid side/ Gas side mm(inch) Φ9.52/Φ19(3/8"/3/4") Φ9.52/Φ19(3/8"/3/4") Φ9.52/Φ19(3/8"/3/4")
Refrigerant
Max. pipe length m 30 50 50
piping
Max. difference in level m 20 30 30
Controller (Optional) Remote/Wired Remote/Wired Remote/Wired
Operation temperature ℃ 17~30 17~30 17~30
Ambient Indoor(cooling/heating) ℃ 17~32/0~30 17~32/0~30 17~32/0~30
temperature Outdoor(cooling/heating) ℃ 0~50/-15~24 0~50/-15~24 0~50/-15~24
Application area m2 48-70 61-90 73-107

Note: All features and specifications are subject to change without prior
notice for product improvement purposes. (* means optional )
PRODUCT CONCEPT

GA Floor standing
Adopts simple and bright style panel.

IDU for 24-55K CDU for 24K CDU for44K~ 55K

GA Series are suitable for most different space and show in good taste.
TECHNICAL SPECIFICATION
Fix Speed Floor Standing
Indoor unit customer model 42KFG024FS19 42KFG044FS 42KFG055FS
Outdoor unit customer model 38KUS024FS 38KFG044FS 38KUS055FSA
Power supply Ph-V-Hz 1Ph- 220~240V- 50Hz 3Ph- 380-415V- 50Hz 3Ph- 380-415V- 50Hz
Power supply from Indoor Indoor Indoor
Capacity Btu/h 25000 44000 54000
Cooling Input W 2600 5100 6250
(Rating
performance) Current A 12.7 8.7 10.3
EER W/W 2.8 2.5 2.5
Rated(Max) input consumption kW 3700 6100 8500
Rated(Max) current A 18.0 12 13.0
Indoor air flow (Turbo/High/low) m3/h 1130/990/850 1900/1800/1600 2500/2450/2030
Indoor noise level (Turbo/High/low) dB(A) 48/45/41 57/55/52 53/52/50
Dimension(W*D*H) mm 510×315×1750 550×350×1800 610×390×1925
Indoor unit Packing (W*D*H) mm 660×440×1910 685×480×1910 765×540×2070
Net/Gross weight Kg 35.7/46.9 49.0/64.5 58.5/78.3
Outdoor noise level dB(A) 61 63 63
Dimension(W*D*H) mm 845×363×702 900x350x1170 900×350×1170
Outdoor unit Packing (W*D*H) mm 965×395×775 1032x443x1307 1032×443×1307
Net/Gross weight Kg 51.0/54.5 91.5/103.0 92.5/104.0
Refrigerant (R410A) g 1400 3000 3100
Design pressure Mpa 4.2/1.5 4.2/1.5 4.2/1.5
Liquid side/ Gas side mm (inch) Φ9.52/Φ15.9(3/8"/5/8") Φ9.52/Φ19(3/8"/3/4") Φ9.52/Φ19(3/8"/3/4")
Refrigerant pipingMax. pipe length m 25 50 50
Max. difference in level m 15 30 30
Controller Remote Remote Remote
Operation temperature ℃ 17~30 17-30 17-30
Indoor(cooling) ℃ 17~32 17-32 17-32
Ambient temperature
Outdoor(cooling) ℃ 18-43 18-43 18-43
Application area m2 33~49 60~88 72~105

*
Note: All features and specifications are subject to change without prior
notice for product improvement purposes. (* means optional )
New Remote Control

Note:
1 .Above illustration shows all the features. For actual model, only
the relevant parts are shown.
2. Buttons design might be slightly different from the actual one.
Wired Control

ON/OFF
Used to start/stop the air
conditioner.

Timer On Temperature UP
Press to set the timer to Increases temperature in
turn unit on. 1 ℃ increments.

Temperature Down
Timer Off Decreases temperature in
Press to set the timer to 1 ℃ increments.
turn unit off.
ECO
Follow Me Used to activate/deactivate
Allows the remote control to ECONOMY Mode, in
act as a remote thermostat and which the unit maintains
relay temperature information a comfortable temperature
from its current location. during sleeping hours.

Swing
Auxiliary Heater Starts and stops the louver
Activate the optional auxiliary movement and sets the
heater. desired air flow direction.

Mode Fan
Press the mode button to Press to select the fan
switch the mode in turn. speed.

RESET LOCK
Used to restore the system Used to lock/unlock
to its default settings. the current setting.

Note:
1 .Above illustration shows all the features. For actual model, only
the relevant parts are shown.
2. Buttons design might be slightly different from the actual one.
3. For the new slim cassette Panel not support the 12B wired
controller, you could select 120G2 or 120X2 controller to
connect indoor main control board. You also consult us before
you purchase it.
Outdoor Features

Golden Fin Anti-corrosion Condenser Coil ( Optional )

The unique anticorrosive coating on the condenser can withstand the


salty air, rain and other corrosive elements.

The Golden coating is denser than blue coating, with higher corrosion
resistance in corrosive environment.