Sie sind auf Seite 1von 2

Substrates & Surface Protection

Surface Prep Surface should be dry and free of foreign matter.


Surface prep can be used to NACE 1-3 (SSPC
Selection & Specification Data SP 5-6) when applicable.
Ferrous Should be primed prior to application of MI-DTI
Product Name Mascoat Industrial-DTI
Surfaces Insulating Coating. Since the coating is water-
Product No. MI-DTI based, it is important to have a boundary layer
Description Mascoat Industrial-DTI is a composite of protection to prevent flash rusting.
ceramic insulating coating that provides Non-ferrous The coating can be applied directly to non-
an insulating barrier, protects personnel Surfaces ferrous surfaces. Surface should be clean and
and blocks corrosion all in one application. free of any oil, dirt or other foreign matter.
The coating is specifically designed to be a
multiple purpose coating solving painting and Application Equipment
insulating issues.
Listed below are the general equipment guidelines for the
Features ♦ Excellent thermal insulation at low thickness application of this product.
♦ Excellent personnel protection Airless Sprayer Pump Ratio: 33:1 or larger
♦ Prevents Corrosion Under Insulation (CUI)
♦ Provides anti-condensation protection Output per Cycle: 180cc (Minimum)
♦ Provides inspection ability w/o removal 290cc (Optimum)
♦ Fast cure times Volume: 1.5 gpm (5.7 lpm) or greater
♦ Low VOC Product Hose: 3/8” or larger with no more
♦ Easy application to irregular surfaces than 3’ of 1/4” whip. 1/2”
Base Water-based Acrylic Insulation Coating hose recommended for
length above 50’.
Gloss Flat
Tip Size: 0.017” (for tight spots)
Priming Self priming over non-ferrous materials 0.019─0.023” (Normal use)
(stainless steel & aluminum). Primer required
for carbon steel substrates. Pressure: Minimum of 3000 PSI
Small Spray Please consult Mascoat for the Small
Topcoats Please consult Mascoat.
Application Application Sprayer. This sprayer is excellent
Wet Weight 5.2─5.3 lbs/gallon for small applications and touch-ups.
(0.63 kg/liter)
2
Brush or Roll Not recommended for this coating
Weight Dry Film 0.035 lbs/ft at 20 mils DFT
2
To Area (0.170 kg/m at 0.50 mm DFT)
Application Conditions
Practical Volume 78─80%
Solids Content Surface Surface temperatures for applications should
Temperatures be greater than 60˚F (15˚C). Lower surface
Average 20─22 mils WFT at 70˚─130˚F temperatures will increase dry times.
Thickness per (0.5 mm WFT at 21˚─54˚C)
Coat Applications Ambient & Cold (60˚─139˚F, 15˚─59˚C): For
2 temperatures (surface or ambient ─ whichever is
Practical Dry 50─55 ft /gallon @ 20 mils lower), an initial tack coat is recommended of 10
2
Coat Coverage (1.3 m /liter @ 0.5 mm) mils (0.25 mm or 250 microns). This tack coat will
VOC Content 0.06 lbs/gallon help eliminate sag on vertical wall applications.
(7.6 grams/liter) Tack coat should be dry to touch prior to next
pass. Typical coat thickness should not exceed
Limitations Applications should not exceed 350˚F
20─22 mils (0.5─0.55mm) wet. Coating can be
(176˚C).
reapplied after each coat is thoroughly dry.
Storage Do not subject wet coating in pail form to Hot (>140˚F or >60˚C): Please consult Mascoat.
freezing conditions. Coating should be kept
in a warehouse between 60˚F and 90˚F. Application Product can be applied in successive coats to
Thickness increase insulation ability. There are no upper
limitations.
Dryfall Dryfall within a 3 ft radius

© Mascoat rev: 122618


Other Coating Specifications Cleanup & Safety
English Value Cleanup Equipment may be cleaned with soap & water.
Item Test Method
(Metric Value) Safety Half-face respirator recommended with ammonia
Cyclic Salt Fog Excellent 2000 hrs ASTM B-117 cartridge or better. Eye protection recommended.
UV-A Exposure Excellent 2000 hrs ASTM D-5894 Ventilation Recommended for constricted areas.
Humidity Cabinet Excellent 2000 hrs ASTM D-4585 Caution This material is not for human consumption.
QUV Excellent 2000 hrs ASTM G-154 Clothing Safety clothing & gloves are recommended.
Low ─ 4.98 perms
Permeability
(3.28 grams/24 hrs/m2/mm/hg)
ASTM 1653-03 Dry Times vs. Humidity
2
Transmission Low ─ 4.14 grains/hr/ft ASTM 1653-03
Time Between
Cross Hatch Surface Temperature % Humidity
5A ASTM D-3359 Coats (hours)
Adhesion
10─30% 4.00
Pull Apart Strength 260─360 psi ASTM D-4541 31─50% 5.50
61─70˚F (16─21˚C)
Elongation Rate Above 30% ASTM D-638 51─70% 6.50
>70% 8.00
2
Thermal 0.4381 Btu-in/ft -hr-˚F Thermal Probe 10─30% 2.00
Conductivity (0.0698 W/m/K) Study 31─50% 3.00
71─80˚F (22─26˚C)
51─70% 3.50
Thermal Emittance 0.85 ASTM C-1371
>70% 4.00
Solar Reflectivity 0.82─0.86 ASTM C-1549 10─30% 1.50
Transmittance 0.00 Calculated 31─50% 2.00
81─90˚F (27─32˚C)
Absorptance 0.14─0.18 Calculated 51─70% 2.50
>70% 3.00
Flame Spread Class A ASTM E-84/87
10─30% 1.25
Smoke Developed Class A ASTM E-84/87 31─50% 1.50
91─100˚F (33─37˚C)
Cone Calorimiter >6 ASTM E-1384-97 51─70% 1.75
>70% 2.00
10─30% 1.00
Mixing & Thinning 101─110˚F (38─43˚C)
31─50% 1.25
51─70% 1.50
Mixing Only a mud mixing paddle should be used. >70% 1.75
Use 1/2” drill motor to stir contents with paddle. 10─30% 0.75
Make sure drill is set to reverse to ensure that 31─50% 1.00
the paddle will not mar the bucket’s inner wall. 111─120˚F (44─49˚C)
51─70% 1.25
Please consult Mascoat for paddle, if needed.
>70% 1.50
DO NOT MECHANICALLY SHAKE.
10─30% 0.50
Thinning DO NOT THIN unless authorized in writing by 31─50% 0.75
Mascoat. 121─130˚F (50─54˚C)
51─70% 0.75
Pot life Coating is one part, so no catalyzation is >70% 1.00
needed. Pail can be reused if properly sealed.
Use 90˚ thumb test or moisture meter prior to recoat. This is the estimated
Container 5 gallon pail (18.92 liters) dry time for 15─20 mils (0.38─0.50 mm) of Mascoat Industrial-DTI wet. Dry
time may vary depending on other conditions such as wind or enclosed
Package, Handling & Storage environments. Lighter thickness passes will expedite dry times. Forced
ventilation in confined areas will also expedite dry times.
Container Wet 27.5─28.0 lbs/5 gallon pail
(with pail/lid) (12.47─12.7 kg/18.92 liters)
Net Contents 25.9 lbs/5 gallon pail
(11.7 kg/18.92 liters) Cure Times
Flash Point None
(Setaflash) Temperature Cure Time
Storage Do not subject wet coating in pail form to 50─60˚F (10─15˚C) 60─72 hrs
freezing conditions. Coating should be kept in 61─70˚F (16─21˚C) 48─60 hrs
a warehouse between 60˚F and 90˚F. 71─80˚F (22─26˚C) 36─48 hrs
Shelf Life 18 months shelf life from manufacture date. 81─90˚F (27─32˚C) 20─24 hrs
Caution Do not let product freeze. 91─100˚F (33─37˚C) 18─20 hrs
>100˚F (>37˚C) 14─16 hrs

The data within is true to the best of our knowledge on the date of publication and is subject to change without prior notice. We guarantee our products to conform to
Mascoat quality control. We assume no responsibility for coverage, performance or injuries resulting from use. Liability, if any, is limited to replacement of products. All
logos are property of their respective owners.
www.mascoat.com

Das könnte Ihnen auch gefallen