Sie sind auf Seite 1von 2

Art.-No.

20639

Business Unit Components & Devices

Dosing technology
Dosing system

eco-DUO450

DESCRIPTION
The new and innovative 2-K-precision-volume-dispenser eco-DUO 450 made by
ViscoTec offers a wide range of applications for the 2-component dispensing.

FUNCTIONAL THEORY
preeflow® eco-DUO is a rotating and perfectly pressure-tight displacement system.
Self-sealing rotor/stator design. Conveyance action by medium displacement in the
stator through controlled rotor movement. Safe conveyance without any modifica-
tion of the medium. With its suck back option, preeflow® ensures clean and con-
trolled material or medium cut-off while preventing post-dripping effects.

APPLICATION
On-the-dot dosage with maximum volumetric precision – dot-and-bead application
with application speeds adaptable to track speeds – joint sealing technology.

RANGE OF USES
• electronic packaging • semiconductor • LCD/LED/OLED
• photovoltaic • medica • biological chemistry
• laboratory • optics and photonics • SMD/SMT

TECHNICAL FEATURES
• genuine volumetric dosing • suck back effect
• viscosity-independent dosing • easy to clean
• primary pressure-independent dosing • controllable dosing flow
• pressure-tight no valve • range of dosing pressures up to 40 bar

eco-DUO450
B

Business Unit Components & Devices


163

eco-DUO450

C
D

A
E

B
F
1
D

2x DIN ISO 228


G 1/8"

228
3 4 5
Fig.: Mounting
6 7 8

Front depression
2x Stirnsenkung für for
2x DIN ISO 228
sochet screw M4 M4
Innensechskantschraube A
G 1/8"
14,5

25,5
29
33

E
2

80
45

163
56

M8
D
E
56
so
ve
F
u
D
60,5

F
228

80 F
u
E 1
228 2 3 4
Fig.:Side view 14,5
80

Maße ohne Toleranzangabe Maßstab: 1:2 Gewicht: 1.18 kg


ISO E
nach DIN ISO 2768 f - m - g

Oberflächenangaben nach Werkstoff 1: - Art.Nr. 1: 20639

29
DIN ISO 1302 und DIN 3141 Werkstoff 2: - Art.Nr. 2: -
Datum Name
Diese Zeichnung ist geschütz:
Eine unerlaubte Vervielfältigung Erst. 18.11.10 Hager eco-DUO450 kpl.
TECHNICAL DATA 33
Bearb. - -
sowie Weitergabe an Dritte
Gepr.
verpflichtet zu Schadensersatz mit Antriebseinheit
F
und kann strafrechtliche Blatt
Folgen haben.
Für diese Zeichnung behalten wir 20639.SLDDRW 1/1
DIN
uns nach DIN 34 alle Rechte vor. ViscoTec GmbH 84513 Töging A3
Ersatz für: - Ersetzt durch:
3 4
Weight:5 6 7 8
approx. 1100 gram
4

Material infeed: 1/8“ cylindrical whitworth pipe thread DIN/ISO 228


Material outfeed: static mixer with bayonet socket
Min. operating pressure: 0 bar, self-levelling-fluid
Max. operating pressure: 0 to 20 bar input pressure, non-self-levelling-fluid
Max. dosing pressure(4): up to 40 bar
uns nach DIN 34 alle Rechte vor.
Für diese Zeichnung behalten wir
Folgen haben.
und kann strafrechtliche
verpflichtet zu Schadensersatz
sowie Weitergabe an Dritte
Eine unerlaubte Vervielfältigung
Diese Zeichnung ist geschütz:

Intrinsic tightness(1): approx. 2 bar (reference medium approx. 10mPas at 20°C)

Innensechskantschraube M4
5

Parts in contact with the media: aluminum, anodized

2x Stirnsenkung für
Seals: High-molecular PE, VisChem
Static seals: Viton O ring
ISO E

Motor: 18 - 24 V DC, incremental encoder, planetary gears


Operating conditions: +10°C to +40°C, air pressure 1 bar
Medium temperature: +10°C to +40°C
Gepr.
Bearb.
Erst.

M8
ViscoTec GmbH 84513 Töging

DIN ISO 1302 und DIN 3141

nach DIN ISO 2768 f - m - g


Maße ohne Toleranzangabe
Oberflächenangaben nach
6

Approx. dosing volume per revolution: 0.05 millilitres per revolution


18.11.10

Accuracy of dosing(2):
Datum

± 1%
-

Repeat accuracy: > 99%


Hager

Mixture ratio: 1:1 to 10:1


Name
-

Min. dosing quantity: 0.01 mililitres


Ersatz für:

Werkstoff 2: -
Werkstoff 1: -

Maßstab:
20639.SLDDRW
mit Antriebseinheit
eco-DUO450 kpl.

Volume flow(3): 0.2 to 12 mililitres per minute


7

1:2

(1) Max. dosing pressure and intrinsic tightness will decrease in direct proportion to a decrease in viscosity and increase in direct proportion to an increase in viscosity. Consultation with the manufacturer recommended

(2) Volumetric dosing as absolute deviation in relation to one dispenser revolution. Depends on the viscosity of the dosing medium

(3) Volume flow depends on viscosity, primary pressure and the mixing ratio
- Ersetzt durch:

(4) depends on the static mixer

45 25,5
60,5
Art.Nr. 2:
Art.Nr. 1:

Gewicht:
8

-
20639
1.18 kg
Blatt
1/1
DIN
A3

A
D

B
E
F

ViscoTec Pumpen- u. Dosiertechnik GmbH info@preeflow.com


Geschäftsfeld Komponenten & Geräte www.preeflow.com

Amperstraße 13 - D-84513 Töging a. Inn


Tel.: +49 (0) 8631 – 9274-00
Fax: +49 (0) 8631 – 9274-300
info@viscotec.de
www.viscotec.de
V1.3 01/16

Das könnte Ihnen auch gefallen