Property Details
Dwelling type Semi-detached house Type of BER Rating Existing Dwelling Has a rating been previously submitted Yes
Year of construction 1998 BER Number 101328490
Address line 1 4 Woodville
Date of assessment 28/11/2009 Your Ref.
Address line 2 Killala Road
Date of Plans 28/11/2009 MPRN No. 10017565581
Address line 3 Ballina
Planning reference Is MPRN shared with another dwelling? No
County Co. Mayo
Building Regulations None Shared BER Number
Post code
Developer name
Development name
12/02/2010 Dwelling Details Report Page 2 of 16
Dimension Details
Ventilation Details
Ventilation method Natural ventilation Effective air change rate [ac/h] 0.80
Ventilation heat loss [W/K] 72.00
Building Elements
Doors
Description U-Value [W/m²K] Area [m²] Heat Loss Number of
doors
Front Door Timber 3.00 1.85 5.55 1
Floors
Type Description U-Value [W/m²K] Area [m²] Heat Loss Underfloor
Heating
Ground Floor - Solid 0.44 54.89 24.15 False
Roofs
Type Description U-Value [W/m²K] Area [m²] Heat Loss Insulation Thickness
Pitched Roof – Insulated on Ceiling Main Roof 0.13 51.35 6.68 >= 300 mm
Pitched Roof – Insulated on Ceiling Roof over Utility 0.40 3.54 1.42 Unknown
Walls
Type Description U-Value [W/m²K] Area [m²] Heat Loss Semi Exposed
1 Front West Wood/PVC 0.70 Double-glazed, 2.53 0.76 6.86 2.52 No 12mm N 2.80 Average or
Elevation air filled Unknown
2 Rear East Wood/PVC 0.70 Double-glazed, 3.02 0.76 8.19 2.52 No 12mm N 2.80 Average or
Elevation air filled Unknown
3 Left Side North Wood/PVC 0.70 Double-glazed, 0.25 0.76 0.67 2.52 No 12mm N 2.80 Average or
Elevation air filled Unknown
12/02/2010 Dwelling Details Report Page 6 of 16
Water heating
Are there distribution losses Yes I supplementary elctric immersion used in summer No
Are There storage losses Yes Is there a combi boiler No
Is there a solar water heating system No
Primary circuit loss type Boiler with uninsulated primary pipework and with cylinder thermostat
Adjusted primary circuit loss [kWh/y] 541
Primary circuit loss [kWh/y] 610
Heat gains from water heating system [W] 390.00
Output from main water heater [kWh/y] 5,426.00
Annual Heat gains from water heating 3,419.00 Output from supplementary heater [kWh/y] 0.00
system [kWh/y]
12/02/2010 Dwelling Details Report Page 8 of 16
Lighting 132.00
Appliance and cooking 223.00
Water heating 390.00
Occupants 155.00
Mechanical ventilation 0.00
Heat loss to the cold water network -42.00
Month Mean External Adj Internal Heat Loss Heat Use [kWh] Gain/Loss Utilisation Heat Use [W] Useful Gains
Temp [C] Temp[C] [W] Ratio Factor [W]
totals 260 20
Gains from fans and pumps
117
associated with space heating system
Is there underfloor heating on the ground floor? No U-Value of ground floor [W/m²K] 0.00
Fraction of heating system output from ground floor 0.67
Additional heat loss via envelope element 0.00
Annual space heating requirement [kWh/y] 7,503
12/02/2010 Dwelling Details Report Page 13 of 16
Results
Energy Rating C3