Sie sind auf Seite 1von 13

File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.

ec6
Building Code Information ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS

Governing Code : IBC 2012, ASCE 7-10, CBC 2013, AISC 360-10, NDS 2012, ACI 318-11, ACI 530-11
City Jurisdiction :
Contact Name :
Alternate Contact :
Building Official :
Address : , ,
Phone : Fax : eMail :
Notes :
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Header H1

CODE REFERENCES
Calculations per NDS 2012, IBC 2012, CBC 2013, ASCE 7-10
Load Combination Set : IBC 2012
Material Properties
Analysis Method : Allowable Stress Design Fb - Tension 900.0 psi E : Modulus of Elasticity
Load Combination :IBC 2012 Fb - Compr 900.0 psi Ebend- xx 1,600.0 ksi
Fc - Prll 1,350.0 psi Eminbend - xx 580.0 ksi
Wood Species : Douglas Fir - Larch Fc - Perp 625.0 psi
Wood Grade : No.2 Fv 180.0 psi
Ft 575.0 psi Density 32.210 pcf
Beam Bracing : Completely Unbraced
D(0.276) Lr(0.19)

2-2x6

Span = 3.30 ft

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Uniform Load : D = 0.2760, Lr = 0.190 , Tributary Width = 1.0 ft, (Dead Loads and Live Loads)
DESIGN SUMMARY Design OK .
Maximum Bending Stress Ratio = 0.346: 1 Maximum Shear Stress Ratio = 0.224 : 1
Section used for this span 2-2x6 Section used for this span 2-2x6
fb : Actual = 503.28psi fv : Actual = 50.51 psi
FB : Allowable = 1,454.11psi Fv : Allowable = 225.00 psi
Load Combination +D+Lr Load Combination +D+Lr
Location of maximum on span = 1.650ft Location of maximum on span = 0.000 ft
Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1
Maximum Deflection
Max Downward Transient Deflection 0.008 in Ratio = 5168 >=360
Max Upward Transient Deflection 0.000 in Ratio = 0 <360
Max Downward Total Deflection 0.019 in Ratio = 2107 >=180
Max Upward Total Deflection 0.000 in Ratio = 0 <180

Maximum Forces & Stresses for Load Combinations .


Load Combination Max Stress Ratios Moment Values Shear Values
Segment Length Span # M V Cd C F/V Ci Cr Cm C t CL M fb F'b V fv F'v
D Only 0.00 0.00 0.00 0.00
Length = 3.30 ft 1 0.284 0.185 0.90 1.300 1.00 1.00 1.00 1.00 1.00 0.38 298.08 1048.77 0.33 29.92 162.00
+D+Lr 1.300 1.00 1.00 1.00 1.00 1.00 0.00 0.00 0.00 0.00
Length = 3.30 ft 1 0.346 0.224 1.25 1.300 1.00 1.00 1.00 1.00 0.99 0.63 503.28 1454.11 0.56 50.51 225.00
+D+0.750Lr 1.300 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length = 3.30 ft 1 0.311 0.202 1.25 1.300 1.00 1.00 1.00 1.00 0.99 0.57 451.98 1454.11 0.50 45.36 225.00
+0.60D 1.300 1.00 1.00 1.00 1.00 0.99 0.00 0.00 0.00 0.00
Length = 3.30 ft 1 0.096 0.062 1.60 1.300 1.00 1.00 1.00 1.00 0.99 0.23 178.85 1857.85 0.20 17.95 288.00
Overall Maximum Deflections .
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+Lr 1 0.0188 1.662 0.0000 0.000
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Header H1

Vertical Reactions Support notation : Far left is #1 Values in KIPS .


Load Combination Support 1 Support 2
Overall MAXimum 0.769 0.769
Overall MINimum 0.273 0.273
D Only 0.455 0.455
+D+Lr 0.769 0.769
+D+0.750Lr 0.691 0.691
+0.60D 0.273 0.273
Lr Only 0.314 0.314
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Header H2

CODE REFERENCES
Calculations per NDS 2012, IBC 2012, CBC 2013, ASCE 7-10
Load Combination Set : IBC 2012
Material Properties
Analysis Method : Allowable Stress Design Fb - Tension 2,400.0 psi E : Modulus of Elasticity
Load Combination :IBC 2012 Fb - Compr 1,850.0 psi Ebend- xx 1,800.0 ksi
Fc - Prll 1,650.0 psi Eminbend - xx 930.0 ksi
Wood Species : DF/DF Fc - Perp 650.0 psi Ebend- yy 1,600.0ksi
Wood Grade : 24F - V4 Fv 265.0 psi Eminbend - yy 830.0ksi
Ft 1,100.0 psi Density 32.210 pcf
Beam Bracing : Completely Unbraced

D(0.31) Lr(0.19)

5.125x12

Span = 14.0 ft

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Uniform Load : D = 0.310, Lr = 0.190 , Tributary Width = 1.0 ft, (Dead Loads and Live Loads)
DESIGN SUMMARY Design OK .
Maximum Bending Stress Ratio = 0.412: 1 Maximum Shear Stress Ratio = 0.222 : 1
Section used for this span 5.125x12 Section used for this span 5.125x12
fb : Actual = 1,195.12psi fv : Actual = 73.53 psi
FB : Allowable = 2,898.48psi Fv : Allowable = 331.25 psi
Load Combination +D+Lr Load Combination +D+Lr
Location of maximum on span = 7.000ft Location of maximum on span = 13.029 ft
Span # where maximum occurs = Span # 1 Span # where maximum occurs = Span # 1
Maximum Deflection
Max Downward Transient Deflection 0.124 in Ratio = 1351 >=360
Max Upward Transient Deflection 0.000 in Ratio = 0 <360
Max Downward Total Deflection 0.327 in Ratio = 513 >=240.
Max Upward Total Deflection 0.000 in Ratio = 0 <240.0

Maximum Forces & Stresses for Load Combinations .


Load Combination Max Stress Ratios Moment Values Shear Values
Segment Length Span # M V Cd C F/V Ci Cr Cm C t CL M fb F'b V fv F'v
D Only 0.00 0.00 0.00 0.00
Length = 14.0 ft 1 0.350 0.191 0.90 1.000 1.00 1.00 1.00 1.00 0.98 7.60 740.98 2114.57 1.87 45.59 238.50
+D+Lr 1.000 1.00 1.00 1.00 1.00 0.98 0.00 0.00 0.00 0.00
Length = 14.0 ft 1 0.412 0.222 1.25 1.000 1.00 1.00 1.00 1.00 0.97 12.25 1,195.12 2898.48 3.01 73.53 331.25
+D+0.750Lr 1.000 1.00 1.00 1.00 1.00 0.97 0.00 0.00 0.00 0.00
Length = 14.0 ft 1 0.373 0.201 1.25 1.000 1.00 1.00 1.00 1.00 0.97 11.09 1,081.59 2898.48 2.73 66.54 331.25
+0.60D 1.000 1.00 1.00 1.00 1.00 0.97 0.00 0.00 0.00 0.00
Length = 14.0 ft 1 0.122 0.065 1.60 1.000 1.00 1.00 1.00 1.00 0.95 4.56 444.59 3644.23 1.12 27.35 424.00
Overall Maximum Deflections .
Load Combination Span Max. "-" Defl Location in Span Load Combination Max. "+" Defl Location in Span
+D+Lr 1 0.3272 7.051 0.0000 0.000
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Beam ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Header H2

Vertical Reactions Support notation : Far left is #1 Values in KIPS .


Load Combination Support 1 Support 2
Overall MAXimum 3.500 3.500
Overall MINimum 1.302 1.302
D Only 2.170 2.170
+D+Lr 3.500 3.500
+D+0.750Lr 3.168 3.168
+0.60D 1.302 1.302
Lr Only 1.330 1.330
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Column ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Wood Jambs WJ1

.
Code References
Calculations per 2012 NDS, IBC 2012, CBC 2013, ASCE 7-10
Load Combinations Used : IBC 2012
General Information
Analysis Method : Allowable Stress Design Wood Section Name 2-2x6
End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber
Overall Column Height 12.0 ft Wood Member Type Sawn
( Used for non-slender calculations )
Exact Width 3.0 in Allow Stress Modification Factors
Wood Species Douglas Fir - Larch Exact Depth 5.50 in Cf or Cv for Bending 1.30
Wood Grade No.2 Cf or Cv for Compression
Area 16.50 in^2 1.10
Fb - Tension 900.0 psi Fv 180.0 psi
Ix Cf or Cv for Tension 1.30
41.594 in^4
Fb - Compr 900.0 psi Ft 575.0 psi Iy Cm : Wet Use Factor
12.375 in^4 1.0
Fc - Prll 1,350.0 psi Density 32.210 pcf Ct : Temperature Factor 1.0
Fc - Perp 625.0 psi Cfu : Flat Use Factor 1.0
E : Modulus of Elasticity . . . x-x Bending y-y Bending Axial Kf : Built-up columns 1.0 NDS 15.3.2
Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr : Repetitive ? No
Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns :
X-X (width) axis : Unbraced Length for X-X Axis buckling = 4 ft, K = 1.0
Y-Y (depth) axis : Unbraced Length for X-X Axis buckling = 10 ft, K = 1.0

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Column self weight included : 44.289 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 12.0 ft, D = 0.4550, Lr = 0.3140 k
BENDING LOADS . . .
Wind Loads: Lat. Uniform Load creating Mx-x, W = 0.0570 k/ft
DESIGN SUMMARY .

Bending & Shear Check Results


PASS Max. Axial+Bending Stress Ratio = 0.2726 : 1 Maximum SERVICE Lateral Load Reactions . .
Load Combination +D+0.60W Top along Y-Y 0.3420 k Bottom along Y-Y 0.3420 k
Governing NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Top along X-X 0.0 k Bottom along X-X 0.0 k
Location of max.above base 6.040 ft Maximum SERVICE Load Lateral Deflections . . .
At maximum location values are . . . Along Y-Y 0.2424 in at 6.040 ft above base
Applied Axial 0.4993 k for load combination : +D+0.60W
Applied Mx 0.6156 k-ft
Applied My Along X-X 0.0 in at 0.0 ft above base
0.0 k-ft
Fc : Allowable 893.75 psi for load combination : n/a
Other Factors used to calculate allowable stresses . . .
PASS Maximum Shear Stress Ratio = 0.04318 : 1 Bending Compression Tension
Load Combination +D+0.60W
Location of max.above base 0.0 ft
Applied Design Shear 18.655 psi
Allowable Shear 288.0 psi
Load Combination Results .

Maximum Axial + Bending Stress Ratios Maximum Shear Ratios


Load Combination CD CP Stress Ratio Status Location Stress Ratio Status Location
D Only 0.900 0.585 0.03872 PASS 0.0 ft 0.0 PASS 12.0 ft
+D+Lr 1.250 0.461 0.05763 PASS 0.0 ft 0.0 PASS 12.0 ft
+D+0.750Lr 1.250 0.461 0.05206 PASS 0.0 ft 0.0 PASS 12.0 ft
+D+0.60W 1.600 0.376 0.2726 PASS 6.040 ft 0.04318 PASS 0.0 ft
+D+0.750Lr+0.450W 1.600 0.376 0.2091 PASS 5.960 ft 0.03239 PASS 12.0 ft
+D+0.450W 1.600 0.376 0.2048 PASS 5.960 ft 0.03239 PASS 12.0 ft
+0.60D+0.60W 1.600 0.376 0.2685 PASS 6.040 ft 0.04318 PASS 0.0 ft
+0.60D 1.600 0.376 0.02031 PASS 0.0 ft 0.0 PASS 12.0 ft
.
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Column ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Wood Jambs WJ1

Maximum Reactions Note: Only non-zero reactions are listed.


X-X Axis Reaction Y-Y Axis Reaction Axial Reaction
Load Combination @ Base @ Top @ Base @ Top @ Base
D Only k k 0.499 k
+D+Lr k k 0.813 k
+D+0.750Lr k k 0.735 k
+D+0.60W k 0.205 0.205 k 0.499 k
+D+0.750Lr+0.450W k 0.154 0.154 k 0.735 k
+D+0.450W k 0.154 0.154 k 0.499 k
+0.60D+0.60W k 0.205 0.205 k 0.300 k
+0.60D k k 0.300 k
Lr Only k k 0.314 k
W Only k 0.342 0.342 k k
Maximum Deflections for Load Combinations .
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+Lr 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+0.750Lr 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+0.60W 0.0000 in 0.000 ft 0.242 in 6.040 ft
+D+0.750Lr+0.450W 0.0000 in 0.000 ft 0.182 in 6.040 ft
+D+0.450W 0.0000 in 0.000 ft 0.182 in 6.040 ft
+0.60D+0.60W 0.0000 in 0.000 ft 0.242 in 6.040 ft
+0.60D 0.0000 in 0.000 ft 0.000 in 0.000 ft
Lr Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
+0.60W 0.0000 in 0.000 ft 0.242 in 6.040 ft
Sketches .
Y M-x
0.7690kLoads
5.50 in

Height = 12.0 ft

Load 1 X

2-2x6

0.06klf

3.0 in Loads are total entered value. Arrows do not reflect absolute direction.
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Column ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Wood Jambs WJ2(Trimmer Stud)

.
Code References
Calculations per 2012 NDS, IBC 2012, CBC 2013, ASCE 7-10
Load Combinations Used : IBC 2012
General Information
Analysis Method : Allowable Stress Design Wood Section Name 2-2x6
End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber
Overall Column Height 10.50 ft Wood Member Type Sawn
( Used for non-slender calculations )
Exact Width 3.0 in Allow Stress Modification Factors
Wood Species Douglas Fir - Larch Exact Depth 5.50 in Cf or Cv for Bending 1.30
Wood Grade No.2 Cf or Cv for Compression
Area 16.50 in^2 1.10
Fb - Tension 900.0 psi Fv 180.0 psi
Ix Cf or Cv for Tension 1.30
41.594 in^4
Fb - Compr 900.0 psi Ft 575.0 psi Iy Cm : Wet Use Factor
12.375 in^4 1.0
Fc - Prll 1,350.0 psi Density 32.210 pcf Ct : Temperature Factor 1.0
Fc - Perp 625.0 psi Cfu : Flat Use Factor 1.0
E : Modulus of Elasticity . . . x-x Bending y-y Bending Axial Kf : Built-up columns 1.0 NDS 15.3.2
Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr : Repetitive ? No
Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns :
X-X (width) axis : Unbraced Length for X-X Axis buckling = 4 ft, K = 1.0
Y-Y (depth) axis : Fully braced against buckling along Y-Y Axis

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Column self weight included : 38.753 lbs * Dead Load Factor
AXIAL LOADS . . .
Axial Load at 10.50 ft, D = 2.170, Lr = 1.330 k
DESIGN SUMMARY .

Bending & Shear Check Results


PASS Max. Axial+Bending Stress Ratio = 0.1669 : 1 Maximum SERVICE Lateral Load Reactions . .
Load Combination +D+Lr Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k
Governing NDS Forumla Comp Only, fc/Fc' Top along X-X 0.0 k Bottom along X-X 0.0 k
Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections . . .
At maximum location values are . . . Along Y-Y 0.0 in at 0.0 ft above base
Applied Axial 3.539 k for load combination : n/a
Applied Mx 0.0 k-ft
Applied My Along X-X 0.0 in at 0.0 ft above base
0.0 k-ft
Fc : Allowable 1,284.74 psi for load combination : n/a
Other Factors used to calculate allowable stresses . . .
PASS Maximum Shear Stress Ratio = 0.0 : 1 Bending Compression Tension
Load Combination +0.60D
Location of max.above base 10.50 ft
Applied Design Shear 0.0 psi
Allowable Shear 288.0 psi
Load Combination Results .

Maximum Axial + Bending Stress Ratios Maximum Shear Ratios


Load Combination CD CP Stress Ratio Status Location Stress Ratio Status Location
D Only 0.900 0.792 0.1265 PASS 0.0 ft 0.0 PASS 10.50 ft
+D+Lr 1.250 0.692 0.1669 PASS 0.0 ft 0.0 PASS 10.50 ft
+D+0.750Lr 1.250 0.692 0.1513 PASS 0.0 ft 0.0 PASS 10.50 ft
+0.60D 1.600 0.602 0.05617 PASS 0.0 ft 0.0 PASS 10.50 ft
Maximum Reactions Note: Only non-zero reactions are listed. .
X-X Axis Reaction Y-Y Axis Reaction Axial Reaction
Load Combination @ Base @ Top @ Base @ Top @ Base
D Only k k 2.209 k
+D+Lr k k 3.539 k
+D+0.750Lr k k 3.206 k
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Column ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Wood Jambs WJ2(Trimmer Stud)

Maximum Reactions Note: Only non-zero reactions are listed.


X-X Axis Reaction Y-Y Axis Reaction Axial Reaction
Load Combination @ Base @ Top @ Base @ Top @ Base
+0.60D k k 1.325 k
Lr Only k k 1.330 k
Maximum Deflections for Load Combinations .
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+Lr 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+0.750Lr 0.0000 in 0.000 ft 0.000 in 0.000 ft
+0.60D 0.0000 in 0.000 ft 0.000 in 0.000 ft
Lr Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
Sketches .
Y 3.50k

Height = 10.50 ft
5.50 in

Load 1 X

2-2x6

3.0 in Loads are total entered value. Arrows do not reflect absolute direction.
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Column ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Wood Jambs WJ2(King Stud)

.
Code References
Calculations per 2012 NDS, IBC 2012, CBC 2013, ASCE 7-10
Load Combinations Used : IBC 2012
General Information
Analysis Method : Allowable Stress Design Wood Section Name 3-2x6
End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber
Overall Column Height 12.0 ft Wood Member Type Sawn
( Used for non-slender calculations )
Exact Width 4.50 in Allow Stress Modification Factors
Wood Species Douglas Fir - Larch Exact Depth 5.50 in Cf or Cv for Bending 1.30
Wood Grade No.2 Cf or Cv for Compression
Area 24.750 in^2 1.10
Fb - Tension 900.0 psi Fv 180.0 psi
Ix Cf or Cv for Tension 1.30
62.391 in^4
Fb - Compr 900.0 psi Ft 575.0 psi Iy Cm : Wet Use Factor
41.766 in^4 1.0
Fc - Prll 1,350.0 psi Density 32.210 pcf Ct : Temperature Factor 1.0
Fc - Perp 625.0 psi Cfu : Flat Use Factor 1.0
E : Modulus of Elasticity . . . x-x Bending y-y Bending Axial Kf : Built-up columns 1.0 NDS 15.3.2
Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr : Repetitive ? No
Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns :
X-X (width) axis : Unbraced Length for X-X Axis buckling = 4 ft, K = 1.0
Y-Y (depth) axis : Fully braced against buckling along Y-Y Axis

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Column self weight included : 66.433 lbs * Dead Load Factor
BENDING LOADS . . .
Wind Loads: Lat. Uniform Load creating Mx-x, W = 0.1870 k/ft
DESIGN SUMMARY .

Bending & Shear Check Results


PASS Max. Axial+Bending Stress Ratio = 0.5727 : 1 Maximum SERVICE Lateral Load Reactions . .
Load Combination +D+0.60W Top along Y-Y 1.122 k Bottom along Y-Y 1.122 k
Governing NDS Forumla Comp + Mxx, NDS Eq. 3.9-3 Top along X-X 0.0 k Bottom along X-X 0.0 k
Location of max.above base 5.960 ft Maximum SERVICE Load Lateral Deflections . . .
At maximum location values are . . . Along Y-Y 0.5301 in at 6.040 ft above base
Applied Axial 0.06643 k for load combination : +D+0.60W
Applied Mx 2.020 k-ft
Applied My Along X-X 0.0 in at 0.0 ft above base
0.0 k-ft
Fc : Allowable 2,007.01 psi for load combination : n/a
Other Factors used to calculate allowable stresses . . .
PASS Maximum Shear Stress Ratio = 0.09444 : 1 Bending Compression Tension
Load Combination +D+0.60W
Location of max.above base 12.0 ft
Applied Design Shear 40.80 psi
Allowable Shear 288.0 psi
Load Combination Results .

Maximum Axial + Bending Stress Ratios Maximum Shear Ratios


Load Combination CD CP Stress Ratio Status Location Stress Ratio Status Location
D Only 0.900 0.923 0.002176 PASS 0.0 ft 0.0 PASS 12.0 ft
+D+0.60W 1.600 0.845 0.5727 PASS 5.960 ft 0.09444 PASS 12.0 ft
+D+0.450W 1.600 0.845 0.4295 PASS 5.960 ft 0.07083 PASS 12.0 ft
+0.60D+0.60W 1.600 0.845 0.5727 PASS 5.960 ft 0.09444 PASS 12.0 ft
+0.60D 1.600 0.845 0.000802 PASS 0.0 ft 0.0 PASS 12.0 ft
Maximum Reactions Note: Only non-zero reactions are listed. .
X-X Axis Reaction Y-Y Axis Reaction Axial Reaction
Load Combination @ Base @ Top @ Base @ Top @ Base
D Only k k 0.066 k
+D+0.60W k 0.673 0.673 k 0.066 k
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Column ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Wood Jambs WJ2(King Stud)

Maximum Reactions Note: Only non-zero reactions are listed.


X-X Axis Reaction Y-Y Axis Reaction Axial Reaction
Load Combination @ Base @ Top @ Base @ Top @ Base
+D+0.450W k 0.505 0.505 k 0.066 k
+0.60D+0.60W k 0.673 0.673 k 0.040 k
+0.60D k k 0.040 k
W Only k 1.122 1.122 k k
Maximum Deflections for Load Combinations .
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+0.60W 0.0000 in 0.000 ft 0.530 in 6.040 ft
+D+0.450W 0.0000 in 0.000 ft 0.398 in 6.040 ft
+0.60D+0.60W 0.0000 in 0.000 ft 0.530 in 6.040 ft
+0.60D 0.0000 in 0.000 ft 0.000 in 0.000 ft
+0.60W 0.0000 in 0.000 ft 0.530 in 6.040 ft
Sketches .
Y M-x Loads
5.50 in

Height = 12.0 ft
X

3-2x6

0.19klf

4.50 in Loads are total entered value. Arrows do not reflect absolute direction.
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Column ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Typical Wood Stud Wall

.
Code References
Calculations per 2012 NDS, IBC 2012, CBC 2013, ASCE 7-10
Load Combinations Used : IBC 2012
General Information
Analysis Method : Allowable Stress Design Wood Section Name 2x6
End Fixities Top & Bottom Pinned Wood Grading/Manuf. Graded Lumber
Overall Column Height 12.0 ft Wood Member Type Sawn
( Used for non-slender calculations )
Exact Width 1.50 in Allow Stress Modification Factors
Wood Species Douglas Fir - Larch Exact Depth 5.50 in Cf or Cv for Bending 1.30
Wood Grade No.2 Cf or Cv for Compression
Area 8.250 in^2 1.10
Fb - Tension 900.0 psi Fv 180.0 psi
Ix Cf or Cv for Tension 1.30
20.797 in^4
Fb - Compr 900.0 psi Ft 575.0 psi Iy Cm : Wet Use Factor
1.547 in^4 1.0
Fc - Prll 1,350.0 psi Density 32.210 pcf Ct : Temperature Factor 1.0
Fc - Perp 625.0 psi Cfu : Flat Use Factor 1.0
E : Modulus of Elasticity . . . x-x Bending y-y Bending Axial Kf : Built-up columns 1.0 NDS 15.3.2
Basic 1,600.0 1,600.0 1,600.0 ksi Use Cr : Repetitive ? No
Minimum 580.0 580.0 Brace condition for deflection (buckling) along columns :
X-X (width) axis : Unbraced Length for X-X Axis buckling = 4 ft, K = 1.0
Y-Y (depth) axis : Fully braced against buckling along Y-Y Axis

Applied Loads Service loads entered. Load Factors will be applied for calculations. .
Column self weight included : 22.144 lbs * Dead Load Factor
AXIAL LOADS . . .
Dead Load and Live Load: Axial Load at 12.0 ft, D = 0.7660, Lr = 0.5850 k
DESIGN SUMMARY .

Bending & Shear Check Results


PASS Max. Axial+Bending Stress Ratio = 0.3796 : 1 Maximum SERVICE Lateral Load Reactions . .
Load Combination +D+Lr Top along Y-Y 0.0 k Bottom along Y-Y 0.0 k
Governing NDS Forumla Comp Only, fc/Fc' Top along X-X 0.0 k Bottom along X-X 0.0 k
Location of max.above base 0.0 ft Maximum SERVICE Load Lateral Deflections . . .
At maximum location values are . . . Along Y-Y 0.0 in at 0.0 ft above base
Applied Axial 1.373 k for load combination : n/a
Applied Mx 0.0 k-ft
Applied My Along X-X 0.0 in at 0.0 ft above base
0.0 k-ft
Fc : Allowable 438.466 psi for load combination : n/a
Other Factors used to calculate allowable stresses . . .
PASS Maximum Shear Stress Ratio = 0.0 : 1 Bending Compression Tension
Load Combination +0.60D
Location of max.above base 12.0 ft
Applied Design Shear 0.0 psi
Allowable Shear 288.0 psi
Load Combination Results .

Maximum Axial + Bending Stress Ratios Maximum Shear Ratios


Load Combination CD CP Stress Ratio Status Location Stress Ratio Status Location
D Only 0.900 0.319 0.2244 PASS 0.0 ft 0.0 PASS 12.0 ft
+D+Lr 1.250 0.236 0.3796 PASS 0.0 ft 0.0 PASS 12.0 ft
+D+0.750Lr 1.250 0.236 0.3392 PASS 0.0 ft 0.0 PASS 12.0 ft
+0.60D 1.600 0.187 0.1288 PASS 0.0 ft 0.0 PASS 12.0 ft
Maximum Reactions Note: Only non-zero reactions are listed. .
X-X Axis Reaction Y-Y Axis Reaction Axial Reaction
Load Combination @ Base @ Top @ Base @ Top @ Base
D Only k k 0.788 k
+D+Lr k k 1.373 k
+D+0.750Lr k k 1.227 k
File = \\bnserver\redirectedfolders\BNguyen\Desktop\Projects\bn#16-247\bn-16-247.ec6
Wood Column ENERCALC, INC. 1983-2017, Build:6.17.1.31, Ver:6.17.1.31
Lic. # : KW-06005589 Licensee : BAKKUM NOELKE STRUCTURAL ENGINEERS
Description : Typical Wood Stud Wall

Maximum Reactions Note: Only non-zero reactions are listed.


X-X Axis Reaction Y-Y Axis Reaction Axial Reaction
Load Combination @ Base @ Top @ Base @ Top @ Base
+0.60D k k 0.473 k
Lr Only k k 0.585 k
Maximum Deflections for Load Combinations .
Load Combination Max. X-X Deflection Distance Max. Y-Y Deflection Distance
D Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+Lr 0.0000 in 0.000 ft 0.000 in 0.000 ft
+D+0.750Lr 0.0000 in 0.000 ft 0.000 in 0.000 ft
+0.60D 0.0000 in 0.000 ft 0.000 in 0.000 ft
Lr Only 0.0000 in 0.000 ft 0.000 in 0.000 ft
Sketches .
Y 1.351k

Height = 12.0 ft
5.50 in

Load 1X

2x6

1.50 in Loads are total entered value. Arrows do not reflect absolute direction.