Committee Approval for Final Standard Specifications TECHNICAL TERMS - CHAPTER 4 - ENGINEERING SPECIFICATIONS E — Pipeline works Specifications Specifications PS 01 - SERVICE CONNECTIONS MATERIALS & INSTALLATION Item 15. GRP WALL MOUNTED WATERMETER BOXES The attached documents are the final revised amended copy of the above mentioned specifications under technical terms checked and signed by ‘Standards and Specification Committee':- NAME POSITION SIGNATURE Engr. AREF BARHAMA Director of Asset Management Dept. Engr. HISHAM MAHMOUD Acting Director of O&M Dept. Engr. OSAMI BAYOMI Chief Engineer ,West- A Ajman Engr. EMAN TAWFIQ Head of Standards & Specification Division. Engr. JAWAHER HAMAD ‘Standards & Specs. Engineer Engr. THOMAS VERGIS Head of Design Division Eng. HAMRUDEEN BASHERILDIN | Design Engineer- Mechanical Engr. MERAJ MOHSIN KHAN. Design Engineer(CIVIL) Endorsed By: —— ‘AREF A.BARHAMA ACTING EXECUTIVE DIRECTOR OF WATER DIRECTORATE Date: 5/2016 FEWA_WD_12_AM_PO7_12 ze! — oo Federal Electricity & Water Authority Water Directorate Asset Management Department STANDARD SPECIFICATIONS FOR WATER WORKS TECHNICAL TERMS Chapter - 4 Engineering Specifications E - Pipeline works Specifications PS 01 SERVICE CONNECTIONS MATERIALS & INSTALLATION (dient FEDERAL ELECTRICITY AND WATER AUTHORITY (FEWA) ppejest STANDARD SPECIFICATIONS FOR WATER WORKS. ~~ “NSE _Eroneer WATER DIRECTORATE - ASSET MANAGEMENT DEPARTMENT |e” Technical Terms / Chapter 47 Engineering Speciicaions / Pipeline Works Spociicatione WAM Pst SERVICE CONNECTIONS MATERIALS & NSTALLAION [ies DUBAT [erser— [Dosimert: MWA PRO_OTWAMLO4-PSO1 [rv JUNEOTS wot 1 [ek 2 SERVICE CONNECTIONS MATERIALS & INSTALLATION 15. GRP WALL MOUNTED WATERMETER BOXES ‘The water meter cabinet shall be of robust construction of GRP with a UV stabiliser gelcoat. The cabinet shall have a lockable door . ‘The following features shall be available with the cabinet. * Cabinet Body - high-class GRP, wall thickness should not be less than 3mm (Materials: Gel Cost, Resin, Chopped Strand Mat, Peroxide, UV Inhibitor. The resin to be UV Stabilized),the body shall have closed ccover in all sides and access from front side only.(no cut out at rear side) + Size 600 Height x 400 Width x 200 Depth. mm + The cabinet shall have hinged door in front with superior quality and 2 no, of square lock * Hinges ~ Heavy duty lift off type stainless steel 316 grade, hinges have 180° door opening * Finish: Smooth and plain semi gloss UV resistant gel coat finish to RAL 7036 or as approved by FEWA. + Text - FEWA Water Meter embossed in both Arabic and English or as approved by FEWA.No logo required ‘+ The doors sealing should be provided with long life,bulb type suitable EPDM gaskel(high tempearture resisitant) to prevent entrance of moisture and humidity ‘+ Suitable natural ventilating arrangement should be provided for proper heat disspation.(vent and drain holes) + Pipe inlet and outlet holes (75 mm)shall be provided at bottom and at tob centre or side of cabinet ‘The holes type shall be slotted or as approved by FEWA. * Fire resistance-fire retardant,self extinguishing to BS476, part 7, class 2. * Allard wares should be of stainless steel or fixing to wall expansion bolts of a minimum 10 mm shall be supplied. Note: 1. The water meter cabinet manufacturer should have ISO 9001/2000 or other approved equivalent Quality Control Certificate. 2. The manufacturer should have reference of supply of at least 3 years in GCC region with proven record. 3. One sample of cabinet with complete accessories and marking shall be submitted for Authority review. Engineer WATER DIRECTORATE - ASSET MANAGEMENT DEPARTMENT [alent FEDERAL ELECTRICITY AND WATER AUTHORITY [FEWA), ae lpwject STAI ‘SPECIFICATIONS FOR WATER WORKS tile: “Technical Terms / Chapter 4/ Engineering Specifications / Pipaline Works Specifications: WAM P01 SERVICE CONNECTIONS MATERIALS & NSTALLATON fice: DUBAI Jerior [Document MWA_PRO_O7IWAW-04-PSOT [rer JUNEI@DI8 Iareot 2 [or 2

Das könnte Ihnen auch gefallen