Code: 08008002
Ionicore (UF) ultrafiltration filter 1/4'' OD Stem 2,5''x11'' (30)

Ultrafiltration is a system which separates water particles between reverse osmosis and microfiltration. It
can be described as synthetic membrane filtration which is used to separate various macromolecules,
colloids, viruses and bacteria. It operates at low pressures in comparison to reverse osmosis, almost
without causing any alterations to the water mineralization. The Ionicore UF ultrafiltration membrane is
produced with polysulphone capillaries, allowing water to pass from outside to inside without rejection, with
nominal filtration at 0,01 microns and a maximum recommended flow of 4 lt/min. The average useful life of
the system is 12.000 litres or one year, if water used is dechlorinated and with pre-filter. The recommended
work pressure for the membrane is between 0,5 and 8,2 bars. The Ionicore UF ultrafiltration membrane
applications are numerous, ideal for water cooler dispensers, reverse osmosis and microfiltration systems.
Ready to use, has no need of housing.

- Micron rating: 0,01 micron


- Max pressure: 120psi (8,2bar)
- Burst pressure: 500psi (34,4bar)
- Max temperature: 113°F (45°C)
- Flow rate: (1gpm) 4lt./min.
- Service life: (3.174gal.) 12.000lt.
- Dimensions DxH (mm.): 62,2x280(mm.) - 2,5”x11"(In.)

- Activation: it's advisable to run water through membrane at maximum pressure and full flow rate, for at
least 5 minutes to allow air purging and flushing.
- Membrane change: When capacity is reached, or when flow comes too slow (precipitates under
0,7bar/10psi), every 12 months.

Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection
before or after the system. Systems certified for cyst reduction may be used with disinfected water that may
contain filterable cysts. All systems must be maintained according to producer instructions.
Nota bene: The contaminants or other substances removed or reduced by this drinking water system are
not necessarily in your water.

20 January 2021 3/5


Code: 080001
Housing and ultrafiltration (UF) membrane set and spare parts
1/4"

Variants
Code Description
080001-03 Ultrafiltration (UF) replacement membrane
080001-04 Housing wrench

Ultrafiltration is a system which separates water particles between reverse osmosis and microfiltration. It
can be described as synthetic membrane filtration which is used to separate various macromolecules,
colloids, viruses and bacteria. It operates at low pressures in comparison to reverse osmosis, almost
without causing any alterations to the water mineralization. The MF2000 ultrafiltration membrane is
produced with polysulphone capillaries, allowing water to pass from the outside to the inside without
rejection, with nominal filtration between 0.1 and 0.01 microns and a maximum recommended flow of 1.5
lt/min. The average useful life of the system is 11,000 litres or one year, providing that the water used is
dechlorinated and subjected to a 1-micron filtering pretreatment process. The recommended work pressure
for the membrane is between 0,5 and 4 bars, and it is used as bacterial safety treatment in point-of-use
equipment, such as domestic dechlorinators, fountains and post-treatment reverse osmosis systems.

Specifications
* Material: Polysulfone * Outer diameter: 460 * Inner diameter: 280 * Pressure: 0,5~4,0bar * Micron rating: