Sie sind auf Seite 1von 88

aerospace

climate control
electromechanical
filtration
fluid & gas handling
hydraulics
pneumatics
process control
sealing & shielding

Denison GOLD CUP® Product Catalog


Piston Pumps & Motors
For Open & Closed Circuits
HY28-2667-01/GC/NA,EU
Effective: March 01, 2010
Hydraulic Pump Division and Denison Hydraulics

The Hydraulic Pump Division of Parker Hannifin was formed in 2004 when our significant piston pump business was
expanded through the acquisition of Denison Hydraulics. The addition of Denison allowed us to marry the wealth
of knowledge that both companies have in the design, manufacture, and application of piston products in both open
circuit and closed circuit system applications. Since before WWII, Denison products have been chosen for Military
test stand applications and for shipboard hydraulic applications being recognized as technology leaders.

The heavy duty GOLD CUP® series of pumps and motors in this catalog represent a broadening of our product
offering with hydrostatic transmission applications in marine, drilling, and shredding applications, among others. The
tried and true design of the GOLD CUP® product line incorporates features such as integral servo and replenishing
pump, hot oil shuttle, and a unique servo control system; all of which combine to provide a rugged self contained
package which can withstand the harshest of conditions and continue to perform with trouble free long life.

The division is a leading worldwide manufacturer of hydraulic components and systems for earthmoving and
construction vehicles; for mining equipment; for pulp and paper, chemical and other processing equipment; for
ships and ordnance equipment; and for such in-plant machines as machine tools, plastic molding, die casters, and
stamping presses.

The product information, specifications, and descriptions contained in this publication have been compiled for
the use and convenience of our customers from information furnished by the manufacturer; and we can not,
and do not, accept any responsibility for the accuracy or correctness of any description, calculation, specifica-
tion, or information contained herein. No such description, calculation, specification, or information regarding the
products being sold has been made part of the basis of the bargain, nor has same created or amounted to an
express warranty that the products would conform thereto. We are selling the goods and merchandise illustrated
and described on this publication on an “as is” basis, and disclaim any implied warranty, including any warranty of
merchantability or warranty of fitness for any particular purpose whatsoever, with respect to the goods and mer-
chandise sold. All manufacturer warranties shall be passed on to our customers, but we shall not be responsible
for special, indirect, incidental, or consequential damages resulting from the use of any of the products or informa-
tion contained or described on this publication. Further, we reserve the right to revise or otherwise make product
improvements at any time without notification.

WARNING - USER RESPONSIBILITY


FAILURE OR IMPROPER SELECTION OR IMPROPER USE OF THE PRODUCTS DESCRIBED HEREIN OR RELATED ITEMS CAN CAUSE DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE.
This document and other information from Parker-Hannifin Corporation, its subsidiaries and authorized distributors provide product or system options for further investigation
by users having technical expertise.

The user, through its own analysis and testing, is solely responsible for making the final selection of the system and components and assuring that all performance, endurance,
maintenance, safety and warning requirements of the application are met. The user must analyze all aspects of the application, follow applicable industry standards, and follow
the information concerning the product in the current product catalog and in any other materials provided from Parker or its subsidiaries or authorized distributors.
To the extent that Parker or its subsidiaries or authorized distributors provide component or system options based upon data or specifications provided by the user, the user is
responsible for determining that such data and specifications are suitable and sufficient for all applications and reasonably foreseeable uses of the components or systems.

OFFER OF SALE
The items described in this document are hereby offered for sale by Parker-Hannifin Corporation, its subsidiaries or its authorized distributor. This offer and its acceptance
are governed by the provisions stated in the detailed "Offer of Sale" elsewhere in this document.

© Copyright 2010, Parker Hannifin Corporation. All Rights Reserved.


Mining Photo on Front Cover is the Property of Atlas Copco.

2
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Contents GOLD CUP® Series - Open & Closed Circuits

Contents
Contents .............................................................................................................................................................3
Technical Data ...............................................................................................................................................4
Features ..............................................................................................................................................................7
Description .......................................................................................................................................................8
Pump, Motor Dimensions
P6, 7, 8 ....................................................................................................................................................................10
M6, 7, 8....................................................................................................................................................................14
P11, 14 ....................................................................................................................................................................17
M11, 14....................................................................................................................................................................21
P24, 30 ....................................................................................................................................................................24
M24, 30....................................................................................................................................................................29
Controls Dimensions
10, 2A ................................................................................................................................................................34, 41
2H, 4A......................................................................................................................................................................35
5A, 5C................................................................................................................................................................36, 41
7D, 7J ......................................................................................................................................................................37
7F, 7K ......................................................................................................................................................................38
8A, 8C................................................................................................................................................................39, 42
9A, 9C................................................................................................................................................................40, 42
**4............................................................................................................................................................................43
**6, **8, **2 ..............................................................................................................................................................44
Rear Adapters
table.........................................................................................................................................................................45
P6,7,8 .................................................................................................................................................................46-47
P11,14 ..........................................................................................................................................................46, 48-50
P24,30 ................................................................................................................................................................51-54
Inlet Conditions ...........................................................................................................................................55
Performance Curves ...........................................................................................................................56-61
Pump Primary Displacement Control Options...................................................................62-70
Secondary Control Options ............................................................................................................70-71
Hydraulic Schematics ........................................................................................................................72-76
GOLD CUP® Pump Control Combinations...................................................................................77
Pump Ordering Code ...........................................................................................................................78-79
GOLD CUP® Motor Control Combinations ..................................................................................81
Motor Ordering Code ...........................................................................................................................82-83
Offer of Sale ...................................................................................................................................................87

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 3
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Technical Data GOLD CUP® Series - Open & Closed Circuits

Series Terms P6 P7 P8 P11 P14 P24 P30


Displacement Max. displacement in3/rev. 6.00 7.25 8.00 11.00 14.00 24.60 30.60
cm3/rev. 98,3 118,8 131,1 180,3 229,5 403,2 501,5
Pressure Continuous psi 5000 5000 3600 5000 5000 50001) 50001)
bar 350 350 250 350 350 3501) 3501)
Intermittent psi 60007) 60007) 45007) 60007) 60007) 55001)7) 55001)7)
bar 4207) 4207) 3107) 4207) 4207) 3701)7) 3701)7)
Speed (Pump) max. @ full stroke rpm 3000 3000 2100 2400 2400 21002) 1800
(Motor ) max. @ full stroke rpm 3000 3000 NA 2400 2400 21002) 1800
(Motor ) max. @ 50% stroke rpm 3600 3600 NA 2800 2800 21002) 1800
Mounting Flange -2 bolt SAE 127-2 (C) 127-2 (C) 127-2 (C) - - - -
Flange -4 bolt (opt. on 6,7 & 8) SAE 152-4 (D) 152-4 (D) 152-4 (D) 165-4 (E) 165-4 (E) 177-4 (F) 177-4 (F)
Shaft - keyed SAE 32-1 (C) 32-1 (C) 32-1 (C) 44-1 (E) 44-1 (E) 50-1 (F) 50-1 (F)
keyed SAE 44-1 (D) 44-1 (D) 44-1 (D) - - - -
Shaft - splined SAE 32-4 (C) 32-4 (C) 32-4 (C) 44-4 (E) 44-4 (E) 50-4(F) 50-4 (F)
splined SAE 44-4 (D) 44-4 (D) 44-4 (D) - - - -
Weight (Pump) less controls lbs 175-300 175-300 175-300 325-530 325-530 750-835 750-835
Mass kg. 80-135 80-135 80-135 145-240 145-240 340-375 340-375
Weight (Motor Fixed) lbs 110 110 N/A 250 250 510 600
Mass kg. 50 50 N/A 110 110 230 270
Weight ( Motor Variable) less controls lbs 110 110 N/A 300 300 650 670
Mass kg. 50 50 N/A 135 135 290 300
Rotating inertia lbs-in2 92 92 92 290 290 821 977
kg.m2 0,027 0,027 0,027 0,085 0,085 0,240 0,286
Torque (Motor) theo. max. per 100 psi lbs-in 95.5 115.4 NA 175 222 392 487
per 100 bar Nm 157 189 NA 287 362 623 797
at 5000 psi lbs-in 4774 5769 NA 8750 11100 19576 24351
at 350 bar Nm 539,5 651,9 NA 990 1250 2158 2752
Power (Motor) theo. max.at 5000 psi, 350 bar
per 100 rpm hp 7.6 9.2 NA 13.8 17.6 31.1 38.6
kW 5,7 6,8 NA 10,3 13,1 23,1 28,8
at 2000 rpm hp 151.5 183.1 NA 277.8 353.5 621.3 695
kW 113,0 136,6 NA 207,0 263,7 463,5 518,2
Torque (Motor) efficiency - approx. stalled % theo. 81 81 NA 81 81 81 81
running % theo. 93 93 NA 93 93 93 93
Case pressure: max. allowable continuous psi 75 75 75 75 75 75
bar 5,2 5,2 5,2 5,2 5,2 5,2 5,2 5,2
intermittent psi 125 125 125 125 125 125 125
bar 8,6 8,6 8,6 8,6 8,6 8,6 8,6
(Not to exceed 25 psi,1,7 bar above inlet in open circuit units)
Flow (Pump) theo.at max.displ.@1500 rpm gpm 39 47 52 71 91 160 199
lpm 148 178 197 269 344 606 753
@1800 rpm gpm 47 57 62 86 109 192 238
lpm 178 216 235 326 413 727 901
Displacement (Internal aux. pump) P6,7,8P,S,V P11,14P,S P11,14V P24P P24S3) P30P P30S3)
in3/rev. 1.07 (2) 1.074) 1.075) 2.816) 2.816) 2.816) 2.816)
cm3/rev. 17,5 (2) 17,5 17,5 46,1 46,1 46,1 46,1
Flow (Internal aux. pump) @1500 rpm gpm 6.9 (2) 6.9 6.9 18.2 6.5 18.2 6.5
lpm 26,1 (2) 26,1 26,1 68,9 24,6 69,1 24,6
@1800 rpm gpm 8.3 (2) 8.3 8.3 21.9 7.8 21.9 7.8
lpm 31,4 (2) 31,4 31,4 82,9 29,5 82,9 29,5

1) Max. pressure 5000 psi, (350 bar) for M24 and 30 series variable motors. Higher servo pressure may be required - consult Parker.

2) On HF-1 fluids, 1800 RPM Max. on HF-0 fluids.

3) Internal cartridge provides servo flow and must be supercharged from external replenishing flow, from external auxiliary pump.

4) One servo cartridge and one replenishing cartridge.

5) Servo cartridge only.

6) Standard, other sizes available, see ordering code.

7) 10% of operation time, not exceeding 6 successive seconds.

Parker Hannifin Corporation


Hydraulic Pump Division
4 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Technical Data GOLD CUP® Series - Open & Closed Circuits

Replenishing pressure (Internal aux. pump) P6,7,8,11,14,24P P6,7,8,11,14,24S P30P P30S


Replenish pressure minus case pressure psi 180-220 * 180-220 180-220 *180-220
bar 12,4-15,2 12,4-15,2 12,4-15,2 12,4-15,2
Servo pressure (Internal aux. pump) psi 308-420 308-420 308-420 308-420
Servo pressure minus case pressure bar 21,2-29,0 21,2-29,0 21,2-29,0 21,2-29,0
at 0 psi, 0 bar discharge pressure
Servo pressure (Internal aux. pump) (Above
repl.)
psi 500-650 500-650 500-650 500-650
for HI-IQ control units. Servo pressure minus bar 34,5-44,8 34,5-44,8 34,5-44,8 34,5-44,8
case pressure at 5000 psi, 350 bar discharge pressure - at system pressure range 0 to 5000 psi, 350 bar.

*Note: Nominal setting, may be increased if required.

Series Terms P6 P7 P8 P11 P14 P24 P30


Controls
Compensator response off-stroke sec. 0.05 0.05 0.05 0.07 0.07 0.10 0.10
(per SAE J497 @ 5000 psi, 350 bar) on-stroke sec. 0.9 0.9 0.9 1.5 1.5 1.8 1.8
Compensator adjustment psi/turn 2000 2000 2000 2000 2000 2000 2000
bar/turn 138 138 138 138 138 138 138
Torque to turn rotary servo shaft in.-lbs 20 20 20 20 20 20 20
Nm 2,3 2,3 2,3 2,3 2,3 2,3 2,3

The maximum inlet at the auxiliary pump inlet is 200 psi. (13,8 bar)

Minimum compensating pressure will always be 100-200 psi. (6,9-13,8 bar) over servo pressure.

Any inlet pressures above atmospheric will increase noise levels and decrease efficiencies noted in this literature. Exact measurements depend
on each application and operating conditions. Please consult your nearest Parker Office for further details.

*Standard factory compensating pressure is 1,000 psi. (69,0 bar).

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 5
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Technical Data GOLD CUP® Series - Open & Closed Circuits

REAR DRIVE TORQUE CAPACITY


FRONT INPUT SHAFT REAR MOUNTINGS REAR OUTPUT SHAFT
SAE
SERIES TYPE TORQUE CAPACITY A B C D E F TORQUE CAPACITY
P6,7,8 Keyed SAE 32-1(C) 6920 in-lbs. • • 1750 in-lbs.
P,S,V,X Spline SAE 32-4(C) (780 Nm) • • (195 Nm)
P6,7,8 Keyed SAE 44-1(D) 6920 in-lbs. • • 1750 in-lbs.
P,S,V,X Spline SAE 44-4(D) (780 Nm) • • (195 Nm)
P6,7,8 Keyed SAE 32-1(C)* 13,845 in-lbs. • • • 6920 in-lbs.
R,L,D only Spline SAE 32-4C (1565 Nm) • • • (780 Nm)
P11,14 Keyed SAE 44-1(E) 13,370 in-lbs. • • • 2400 in-lbs.
P,S,V,X Spline SAE 44-4(E) (1510 Nm) • • • (270 Nm)
P11,14 Keyed SAE 44-1(E)* 26735 in-lbs. • • • • • 13,370 in-lbs.
R,L only Spline SAE 44-4(E) (3020 Nm) • • • • • (1510 Nm)
P24,30 Keyed SAE 50-1(F) 24350 in-lbs. • • 2700 in-lbs.
P,S,X Spline SAE 50-4(F) (2750 Nm) • • (305 Nm)
P24,30 Keyed SAE 50-1(F) 48,700* in-lbs. • • • • • 24,350 in-lbs
R,L only Spline SAE 50-4(F) (5,500 Nm) • • • • • (2750 Nm)
* Coupling for keyed shaft must be pressed fit for full torque capability.

P6/7/8 SAE 127-2 Mtg., 32-1, 4 Shaft Bearing 230-82140 (6007)


Speed (rpm) 1000 1000 1000 1000 1200 1200 1200 1200 1500 1500 1500 1500 1800 1800 1800 1800
Shaft Load (lbs) * 0 0 1000 1000 0 0 10 00 1000 0 0 1000 1000 0 0 1 000 1000
Shaft Load (N) * 0 0 4448 4 448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448
Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25
Case Pressure (bar) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7
B-10 Life (hours x 1000) 8E+08 1833 0.778 0.778 6E+08 1528 0.648 0.648 5E+08 1222 0.518 0.518 4E+08 1018 0.432 0.432

P6/7/8 SAE 152-4 Mtg., 44-1, 4 Shaft Bearing 230-00207-0 (6207)


Speed (rpm) 1000 1000 1000 1000 1200 1200 1200 1200 1500 1500 1500 1500 1800 1800 1800 1800
Shaft Load (lbs) * 0 0 1000 1000 0 0 1000 1000 0 0 1000 100 0 0 0 1000 1000
Shaft Load (N) * 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448
Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25
Case Pressure (bar) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7
B-10 Life (hours x 1000) 3E+09 7394 3.136 3.136 3E+09 6161 2.613 2.613 2E+09 4929 2.09 2.09 2E+09 4170 1.742 1.742

P11/14 SAE 165-4 Mtg., 44-1, 4 Radial Shaft Bearing 230-82148-0 (6010) (2 & 3 Shaft Codes)
Speed (rpm) 1000 1000 1000 1000 1200 1200 1200 1200 1500 1500 1500 1500 1800 1800 1800 1800
Shaft Load (lbs) * 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000
Shaft Load (N) * 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448
Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25
Case Pressure (bar) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7
B-10 Life (hours x 1000) 2E+09 535 1.907 1.907 2E+09 446 1.589 1.589 1E+09 356 1.272 1.272 1E+09 297 1.06 1.06

P11/14 SAE 165-4 Mtg., 44-1, 4 Spherical Roller Shaft Bearing 230-82214-0 (22208) (7 & 8 Shaft Codes)
Speed (rpm) 1000 1000 1000 1000 1200 1200 1200 1200 1500 1500 1500 1500 1800 1800 1800 1800
Shaft Load (lbs) * 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000
Shaft Load (N) * 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448
Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25
Case Pressure (bar) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7
B-10 Life (hours x 1000) 16856 2452 275 172 14046 2043 230 143 11237 1635 184 114.8 9364 1363 153 95.7

P24 SAE 177-4 Mtg., 50-1, 4 Shaft Bearing 230-82213-0 (22311)


Speed (rpm) 1000 1000 1000 1000 1200 1200 1200 1200 1500 1500 1500 1500 1800 1800 1800 1800
Shaft Load (lbs) * 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000
Shaft Load (N) * 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448
Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25
Case Pressure (bar) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7
B-10 Life (hours x 1000) 591.6 428.5 276.7 213.5 493 357 230.5 178 394.4 991.6 184.4 142.3 328.7 238 153.7 118.6

P30 SAE 177-4 Mtg., 50-1, 4 Shaft Bearing 230-82213-0 (22311)


Speed (rpm) 1000 1000 1000 1000 1200 1200 1200 1200 1500 1500 1500 1500 1800 1800 1800 1800
Shaft Load (lbs) * 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000 0 0 1000 1000
Shaft Load (N) * 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448 0 0 4448 4448
Case Pressure (psi) 0 25 0 25 0 25 0 25 0 25 0 25 0 25 0 25
Case Pressure (bar) 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7 0.0 1.7
B-10 Life (hours x 1000) 227 177.7 126.4 102.8 189.2 148 105.3 85.6 151.3 118.4 84.2 68.5 126.1 98.7 70.2 57.1
*radial load at center of key or spline

Note: Variation in life is due to variations in tolerances within the pump.


Contact Parker Hydraulics for B-10 with other operating conditions and with other case pressure values.
Consult Parker Hydraulics for shaft side loads of P*R units.

Parker Hannifin Corporation


Hydraulic Pump Division
6 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Features GOLD CUP® Series - Open & Closed Circuits

1 Quick change valve block - easy to 10 Auxiliary pump can be changed without Standard compensator vent ports allow
service or replace disassembling the transmission
15 for a wide variety of controls (See
Applications Manual)
2 Quick change controls - easy to Standard SAE keyed or splined drive
service and change
11 shafts are available Rocker cam displacement indicator helps
16 troubleshoot the system
3 Dampened low inertia rocker cam - High pressure mechanical shaft seals
more stable, quieter and faster than 12 can be changed without disassembling 17 Modulated servo pressure saves power
other designs the transmission. Double lip seals are also
available Standard Code 62 SAE split flange
18 connections
Exclusive zero-backlash rotary servo
4
design - lifetime accuracy One piece stroking vane/cam means no
13 19 Conforms to SAE mounting standards.
lost motion, zero backlash, better control,
5 Field adjustable compensator override - and no linkages to wear out
easily adjusted without removing from 20 Fast compensator response. See page 5.
machinery Stroking vane seals are pressure loaded
14
for longer life Variable motors available for multiple
Precision barrel bearing, a distinctive
21 speed ranges or constant power
6 Denison Hydraulics feature for over 30
years - permits high speeds, high Note: 1. These products, with exception of 8 cubic inch units, are qualified to
pressure and provides long life meet Military specifications MIL-P-17869A and MIL-S-901-C Grade A.

2. All GOLD CUP® Pumps and Motors* have ATEX approval.


Versatile controls - can be located on
7 either side of pump or motor for
*See ordering code for availability.

maximum freedom of design 3. Consult factory for other approvals such as ABS and Lloyd's Registry.

8 Patented ring style replenishing checks


fastest operation with
or parts nolow
and sliding poppets
pressure drop
or parts and low pressure drop 19
Hot oil shuttle available - fast, reliable
9
operation
19
9 Hot oil shuttle available - fast, reliable
21 6
operation
1821
611
12

20 5
1
15

17
2
7 10
6 18
8
16
3

12 4
13
11 2
7
14
19

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 7
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Description GOLD CUP® Series - Open & Closed Circuits

CLOSED HYDRAULIC CIRCUIT Variable Pump/Fixed Motor. This combination provides for a constant torque
output at a fixed maximum pressure over the full speed range. Speed and
direction are controlled with a variable displacement over-center pump. Power
from overhauling loads is regenerated back into the pump prime mover. Motor
speed is limited to the maximum speed permitted by full pump displacement.
System is capable of full power only at maximum pump displacement.
POWER CHARACTERISTICS OF Variable Pump/Variable Motor. This combination provides for an extended range
HYDROSTATIC TRANSMISSIONS of motor speeds. The motor, at full displacement, delivers maximum torque while
its speed and direction respond to displacement changes of the crossover center
pump. Power is proportional to motor speed.
This transmission system has the capability of constant torque and rising power
until the pump reaches full displacement and full power at elevated speeds as
motor displacement and torque are reduced.
PACKAGE PUMP The package pump contains the circuit elements shown in the hydraulic
schematic on pgs. 72-74. These include the axial piston over-center variable
displacement pump which controls the speed and direction of the motor, the
auxiliary pump which supplies servo pressure (for controlling the displacement
of the variable pump) and replenishment pressure, the servo pressure relief
valve, the replenishment pressure relief valve and the replenishment check
valves for ports A and B. The pump package also includes the displacement
control valves as well as an external arm which shows actual displacement.
The various control features are described below.

PACKAGE MOTOR The package motor, shown in schematic pgs. 72-74, contains the axial piston
fluid motor, the shuttle valve that continuously removes hot oil from the low
pressure side of the loop and a relief valve to establish minimum hydraulic loop
pressure at the motor. The fluid motor is available with fixed displacement or
with the variable displacement option. The standard variable motors include an
external indicator which shows displacement.
OPEN CIRCUIT PUMP The open circuit pump contains the circuit elements shown on pages 75,76.
These include a cross-center variable displacement pump which is normally
limited to one side of center. The auxiliary pump supplies only servo pressure
to control the main pump displacement and inlet porting is enlarged to improve
the pump’s inlet characteristics. As the open loop pump operates on one side of
center only, not all controls are available.
AUXILIARY REAR DRIVE Additional auxiliary flow is available with the rear drive pump option. The rear
drive may also be utilized for servo and other purposes. See ordering code for
additional detail.
“R” & “L” style pumps have no rear shaft seal, so any pump driven must be able
to withstand case pressure of the pump driving it.
AUXILIARY PUMP Integral to the package pump’s envelope is the gerotor auxiliary pump.
(P24P, P24S, P30P & P30S have vane integral pump). It provides servo
and replenishing pressure. See page 5 for factory settings.
NOTE: Auxiliary pump inlet must be connected directly to the reservoir.
Customer must supply external line from integral auxiliary pump back into
main pump for filtering servo and/or replenishing oil.
(see installation drawings starting on pg 10.)

Parker Hannifin Corporation


Hydraulic Pump Division
8 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Description GOLD CUP® Series - Open & Closed Circuits

MOUNTING The pump or motor is designed to operate in any position. For vertical mounting
it is recommended that the shaft bearing be drained via the drain port provided.
The mounting hub and mounting flange are in full conformance with SAE
standard. The shaft must be in alignment with the shaft of the driven load and
should be checked with a dial indicator. The mounting pad or adapter into which
the fluid pump pilots must be concentric with the pump shaft within 0.006 in.,
0,152 mm to prevent bearing failure. This concentricity is particularly important if
the shaft is rigidly connected to the driving load without a flexible coupling. The
shaft-coupling interface must be lubricated with lithium molydisulfide or similar
grease.

INLET PRESSURES, In a closed hydraulic loop the pump inlet or the fluid motor inlet (during dynamic
PORTS A & B braking) are supercharged by the integral replenishment system. Consult Parker
in cases where fluid viscosity or dynamics or line size may cause inlet pressure
at either port A or B to be less than the 150 psi, 10,3 bar maintained by the
integral replenishment system. For operation in open loop or combination open-
closed loops, consult Parker.
DRAIN PORT Drain the package pump from the higher drain port. If drain port is above the
fluid level in the tank install a 5 psi, 0,3 bar relief of suitable size in the drain
line to tank. For vertical mounting it is recommended that the shaft bearing be
drained via the drain port provided.
For pump speeds intermittently below 1000 rpm, install a back pressure relief 40
psi, 2,8 bar of suitable size in the drain line from the higher port to tank. Motor
case drain must be connected to pump case.
Motor: Drain the motor from the higher drain ports into the lower pump drain port
or tank. Make provision that the motor drain port pressure will not exceed the
maximum limits specified above.
RETURN LINE FILTER Relatively inexpensive low pressure filters are recommended for installation
in the return lines and drain lines from circuits using these pumps or motors.
Consider the possibility of decompression surges and intensified flow in cylinder
circuits as well as the factors above in selecting return line filters.

AUXILIARY FLOW FILTERS It is recommended the auxiliary pump fluid be filtered to aid in maintaining
acceptable cleanliness levels. For good filtration and reasonable maintenance
intervals the filter capacity must be at least twice the auxiliary pump flow. To use
this feature, install the isolation plug and connect the filter between ports G&H,
(P6,P7,P8,P24,P30), or J&K (P11,P14). See detailed schematics and drawings
pages 10-22 for location of these ports.

RECOMMENDED FLUIDS The fluid recommended for use in these pumps and motors has a petroleum
base and contains agents which provide oxidation inhibition and anti-rust,
antifoam and de-areating properties as described in Parker Denison standard
HF-1. These preferred fluids do not contain anti-wear additives. Fluids containing
anti-wear additives that meet Parker Denison standard HF-0 are acceptable.

VISCOSITY Max. at cold start 7500 SUS, 1600 cSt


at low pressure, low flow and if possible, low speed
Max. at full power 750 SUS, 160 cSt
Optimum for max. life 140 SUS, 30 cSt
Minimum at full power 60 SUS, 10cSt

CLEANLINESS Particle contamination to meet ISO 20/17/14 or better. Water content < 500 ppm
for mineral based fluids. For detail on fluid recommendations see bulletin
SPO-AM305.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 9
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P6-P7-P8F, M Dimensions GOLD CUP® Series - Open & Closed Circuits

1.50 6000 PSI


SAE- DIA.
(38,1) (414 BARS) .72 3.00 3.00 .84
4-BOLT FLG. CONN.
DRAIN CONN. (18,3) (76,2) (76,2) (21,3)
SAE-12 STR. THD.
A L3 D1
"D" CASE DRAIN CONN.
SAE-12 STR. THD.

B A
1.56 1.53
(39,6) (38,9)
3.06
3.12 (77,7)
(79,2)

D2 ALT. DRAIN CONN.


A L4 SAE-12 STR. THD.
1.44
(36,6)
1.68
(42,7)
L2 5/8-11UNC x
1.30
DEEP 2.00 3000 PSI
(33,0) SAE- DIA.
L1 4-PLACES (50,8) (207 BARS)
4-BOLT FLG. CONN.

MOUNTING
MOUNTING L1 L2 L2L3
L1 L4
L3 L4 1/2 -13UNC x
1.05
DEEP

P*F SAE
SAE 127-2
127-2
(SAE-C)
11.19
11.19
(284,2)
11.06 4.90
11.06(124,5)
(280,9)
.85
4.90
(21,6) .85
4-PLACES
(26,7)

SAE 152-4
(SAE-C) 11.59
(284,2) 11.46 (280,9)
5.30 .89
(124,5) (21,6)
(SAE-D) (294,3) (291,1) (134,6) (22,6)
SAE 152-4 11.59 11.46 5.30 .89
(SAE-D) (294,3) (291,1) (134,6) (22,6)

P*M DRAIN CONN. 1.30


DP.
A L3
SAE-12 STR. THD.
D1
5/8-11 UNC-2B TAP x
4 PLACES AS SHOWN
(33,0)

3.12
(79.2)
1.56
(39.6)
3.94 .72
(99,9) .25 (18.3)
(6.4)
1.44
(36.6)

3.94
(99,9)
SYSTEM PORT A (FAR SIDE)
SYSTEM PORT B (NEAR SIDE)
1.50 DIA. 6000 PSI
SAE-
(38.1) (418 BARS)
4-BOLT FLG. CON

A L4 D2 ALT. DRAIN CONN.


SAE-12 STR. THD.

L2
L1
MOUNTING
MOUNTING L1 L1
L2 L3L2 L4 L3 L4
SAE 127-2
SAE 127-2 13.40 13.40
10.14 10.14 .85
4.90 4.90 .85
4.50 (SAE-C) (340,4) (257,6) (124,5) (21,6)
(114,3)
(SAE-C) (340,4) (257,6) (124,5) (21,6)
SAE 152-4 13.80 10.54 5.30 .89
(SAE-D)
SAE 152-4 (350,5) 13.80
(267,7) 10.54 (22,6)
(134,6) 5.30 .89
(SAE-D) (350,5) (267,7) (134,6) (22,6)

4.50
NOTE: See page 16 for shaft information.
(114,3) See pages 45-54 for rear drive information.

Parker Hannifin Corporation


Hydraulic Pump Division
10 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P6-P7-P8V, D, P Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits
(NEAR SIDE) AUXILIARY PUMP OUTLET G H AUXILIARY PUMP (FAR SIDE)
TO EXTERNAL FILTER & SERVO GAGE CONN. FILTER RETURN PORT
SAE-8 STR. THD. SAE-8 STR. THD.

4.50 4.50
A L1 (114,3) (114,3)
ALT. DRAIN CONN. K AUXILIARY REPLENISH PORT .72 3.00 3.00 .84
L3 SAE-12 STR. THD.
D1 SAE-16 STR. THD. (18,3) (76,2) (76,2) (21,3)

L7
5.27
(133,9)
3.87
TYP.
(98,3)

B A
1.56 1.53
(39,6) (38,9)

3.12 3.06
(79,2) (77,7)

3.70
(93,9)

L4 1.44 1.68
L5 (36,6) (42,7)
PORT "B" 1/2-13UNC x 1.05
L2 SAE-
1.50
DIA.
6000 PSI
4-PLACES (26,7)
A (38,1) (414 bar)
4-BOLT FLG. CONN 5/8-11UNC x 1.38
(35,1)
DEEP
BG THIS SIDE
4-PLACES
AG FAR SIDE
ALT. DRAIN CONN. D2
C AUXILIARY PUMP INLET MAIN LOOP GAGE CONN. PORT "A"
SAE-12 STR. THD.
P*V SAE-16 STR. THD.

TABLE 1
SAE-6 STR. THD. 6.0 & 7.25 GOLD CUP®
SAE-
2.00 DIA. 3000 PSI
(50,8) (207 bar)

P*V TABLE 1
MOUNTING L1 L2 L3 L4 L5 L7
4-BOLT FLG. CONN

MOUNTING L1 L2 L3 L4 L5 L7
P*D & P*P SAE 127-2
(SAE-C)
15.51
(393,9)
13.70
(348,0)
7.02
(178,3)
1.00
(25,4)
10.64
(270,3)
5.15
(130,9)
SAE 152-4 16.85 15.04 8.36 .86 11.98 6.49
(SAE-D) (427,9) (382,1) (212,3) (21,8) (304,3) (164,8)

(NEAR SIDE) AUXILIARY PUMP OUTLET G H AUXILIARY PUMP (FAR SIDE)


TO EXTERNAL FILTER & SERVO GAGE CONN. FILTER RETURN PORT
SAE-8 STR. THD. SAE-8 STR. THD.
4.50 4.50
A L1 (114,3) (114,3)
ALT. DRAIN CONN. K AUXILIARY REPLENISH PORT .72 3.00 3.00 .72
L3 SAE-12 STR. THD.
D1 SAE-16 STR. THD. (18,3) (76,2) (76,2) (18,3)

L7
5.27
(133,9)
3.87
TYP.
(98,3)

B A
1.56 1.56
(39,6) (39,6)

3.12 3.12
(79,2) (79,2)

3.70
(93,9)

L4 1.44 1.44
L5 (36,6) (36,6)
1.38
L2 SAE-
1.50
DIA.
6000 PSI 5/8-11UNC x
8-PLACES (35,1)
DEEP

A (38,1) (414 bar)


4-BOLT FLG. CONN
BG THIS SIDE
TYP. PORTS "A" & "B"
AG FAR SIDE
ALT. DRAIN CONN. D2
C AUXILIARY PUMP INLET MAIN LOOP GAGE CONN. NOTE: See page 16 for shaft information.
SAE-12 STR. THD.
SAE-16 STR. THD. SAE-6 STR. THD.
See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 11
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P6-P7-P8X, R Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

(NEAR SIDE) AUXILIARY PUMP OUTLET G H AUXILIARY PUMP (FAR SIDE)


K AUXILIARY REPLENISH AND
TO EXTERNAL FILTER & SERVO GAGE CONN. FILTER RETURN PORT
SAE-8 STR. THD.
PUMP FILTER RETURN PORT
SAE-8 STR. THD.
SAE-12 STR. THD.

A L6 SYSTEM PORT A (FAR SIDE)


ALT. DRAIN CONN. 5.38 5.38
SYSTEM PORT B (NEAR SIDE)
L3 SAE-12 STR. THD.
D1
(136,5) (136,5)
SEE DETAIL "A"
L7
5.27
(133,9)

3.87
(98,3)

.90
(23,0)
.90
(23,0)
B A
3.87
(98,3) 3.70
(93,9)

3.38 R
(85,8)

1.44
ALT. DRAIN CONN. D2
(36,6)
L4 SAE-12 STR. THD. .72 5/8 -11UNC-2B THREAD x
1.31
DEEP
L5 (18,3) 8-PLACES (33,3)

A L2
L1 1.56
C AUXILIARY PUMP INLET
C AUXILIARY PUMP INLET (39,7)
SAE-16 STR. THD.
SAE-16 STR. THD. 3.13
TABLE 3 (79,4)
TABLE 3
MOUNTING L1 L2 L3 L4 L5 L6 L7
MOUNTING L1 L2
SAE 127-2
(SAE-C)
17.27
L3
(438,6)
15.14
(384,6)
L4 7.02
(178,3)
L5
1.00
(25,4)
10.64
(270,3)
L6
16.58
(421,2)
L7
5.15
(130,9)
SAE 127-2 17.27 SAE 15.14 18.61 7.02 16.48 1.00 10.64 11.98 16.58 5.15
152-4
(SAE-D)
8.36 .86 17.92 6.49 SYSTEM PORT A (FAR SIDE)
(SAE-C) (438,6) (384,6) (178,3)(418,6)
(472,6) (25,4)
(212,3) (270,3) (304,3)(421,2)
(21,8) (455,2) (130,9)
(164,8)
SYSTEM PORT B (NEAR SIDE)
P*X SAE 152-4
(SAE-D)
18.61
(472,6)
16.48
(418,6)
8.36
(212,3)
.86
(21,8)
11.98
(304,3)
17.92
(455,2)
6.49
(164,8) SAE-
1.50 DIA. 6000 PSI
(38,1) (414 BARS)
4 BOLT FLG. CONNECTION
4-BOLT

P*R D1 DRAIN CONN.


SAE-12 STR. THD.
5/8-11 UNC-2B TAP x
4 PLACES AS SHOWN
1.30
(33,0)
DP.

A L1 3.12
(79.2)
1.56
L3 (39.6)

L7 .72
(18.3)

1.44
(36.6)
6.07
(154,1)

3.87 .25
(98,3) (6.3)
SYSTEM PORT A (FAR SIDE)
SYSTEM PORT B (NEAR SIDE)
1.50 DIA. 6000 PSI
SAE-
(38.1) (418 BARS)
3.87 TABLE 2 4-BOLT FLG. CON
3.70
(98,3)
(94,0) MOUNTING L1 L2 L3 L4 L5 L6 L7
SAE 127-2 15.51 11.88 7.02 1.00 10.64 15.14 5.15
(SAE-C) (393,9) (301,8) (178,3) (25,4) (270,3) (384,6) (130,9)
SAE 152-4 16.85 13.22 8.36 .86 11.98 16.48 6.49
(SAE-D) (427,9) (335,9) (212,3) (21,8) (304,3) (418,7) (164,8)

L4 ALT. DRAIN CONN. D2 H SERVO GAGE CONN.


SAE-12 STR. THD. SAE-4 STR. THD.
L5
REAR ADAPTER
A L2
L6
(38.1) (418 BARS)
B1 SYSTEM GAGE CONN. K REPLENISHING PORT INLET
SAE-6 STR. THD. SAE-16 STR. THD. TABLE 2 4-BOLT FLG. CON

MOUNTING L1 L2 L3 L4 L5 L6 L7
4.50 SAE 127-2 15.51 11.88 7.02 1.00 10.64 15.14 5.15
4.50 G CONTROL PRESSURE INLET (114,3) (SAE-C) (393,9) (301,8) (178,3) (25,4) (270,3) (384,6) (130,9)
(114,3) SAE-8 STR. THD.
SAE 152-4 16.85 13.22 8.36 .86 11.98 16.48 6.49
(SAE-D) (427,9) (335,9) (212,3) (21,8) (304,3) (418,7) (164,8)

4.50
A1 SYSTEM GAGE CONN.
(114,3)
SAE-6 STR. THD. 4.50
(114,3)
NOTE: See page 16 for shaft information.
See pages 45-54 for rear drive information.
6.02
(152,8) See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
12 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P6-P7-P8S, L Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

(NEAR SIDE) AUXILIARY PUMP OUTLET G H AUXILIARY PUMP (FAR SIDE)


TO EXTERNAL FILTER & SERVO GAGE CONN. FILTER RETURN PORT
SAE-8 STR. THD. SAE-8 STR. THD.

L6
A
ALT. DRAIN CONN.
L3 SAE-12 STR. THD.
D1
"BG" SYS. GAGE (N.S.)
"AG" SYS. GAGE (F.S)
L7 SAE-6 STR. THD.

5.27
(133,9)

3.87
(98,3) SYSTEM PORT A (FAR SIDE)
SYSTEM PORT B (NEAR SIDE)
SEE DETAIL "A"

1.31
5/8 -11UNC-2B THREAD x DEEP
8-PLACES (33,3)

3.87
3.70 1.44
(98,3)
(93,9) (36,6)
.72
(18,3)
6.51
(165,4)

ALT. DRAIN CONN. D2 1.56


L4 SAE-12 STR. THD. (39,7)
L5 3.13
C AUXILIARY PUMP INLET (79,4)
A SAE-16 STR. THD.

L2
L1 DETAIL "A"
SYSTEM PORTS A & B
1.50 DIA. 6000 PSI
SAE-
(38,1) (414 BARS)
4-BOLT
4-BOLT FLG. CONNECTION FLG. CONNECTION
4.50 TABLE 5
5.38
(114,3) (136,5) TABLE 5
MOUNTING L1 L2 L3 L4 L5 L6 L7
SAE 127-2 19.97
MOUNTING
(SAE-C) (507,3)
15.14
L1
(384,6)
7.02
(178,3) L2 1.00
(25,4)
10.64
L3
(270,3)
16.58
(421,2) L4 5.15
(130,9) L5 L6 L7
16.48
SAE 152-4
SAE 127-2 21.31 19.97 8.36
15.14.86 7.02 17.92
11.98 6.49
1.00 10.64 16.58 5.15
(SAE-D) (541,3) (418,6) (212,3) (21,8) (304,3) (455,2) (164,8)
(SAE-C) (507,3) (384,6) (178,3) (25,4) (270,3) (421,2) (130,9)
4.50
5.38 SAE 152-4 21.31 16.48 8.36 .86 11.98 17.92 6.49
(114,3) (136,5)
(SAE-D) (541,3) (418,6) (212,3) (21,8) (304,3) (455,2) (164,8)

P*S "KA" SHUTTLE


RELIEF INLET
"D3" DRAIN CONNECTION
SAE-16 STR. THD.

SAE-12 STR. THD.

G SERVO PRESSURE INLET


ALT. DRAIN CONN.

P*L
SAE-8 STR. THD.
SAE-12 STR. THD.
D1
K AUXILIARY REPLENISH AND
PUMP FILTER RETURN PORT
SAE-12 STR. THD.
A L5
REAR ADAPTER
L3
L7
5.27
(133,9) 1.44
3.87 (36,6)
TYP. .72
(98,3)
(18,3)

2.04
(51,8)
1.56
(39,7)
3.13
7.38 (79,4)
(187,6)

1.31
SYSTEM PORT A (FAR SIDE) 5/8 -11UNC-2B THREAD x DEEP
8-PLACES (33,3)
SYSTEM PORT B (NEAR SIDE)
ALT. DRAIN CONN. D2
1.50 DIA. 6000 PSI
L4 SAE-12 STR. THD. SAE-
(38,1) (414 BARS)
4-BOLT FLG. CONNECTION

A
L2
L1 TABLE 4
"D3" DRAIN CONNECTION
SAE-16 STR. THD. "KA" SHUTTLE RELIEF INLET
SAE-12 STR. THD.
MOUNTING
TABLE 4
L1 L2 L3 L4 L5 L6 L7
MOUNTING
SAE 127-2 L1 L2
17.58 L315.14L4 L57.02 L6 L7
1.00 10.58 16.58 5.15
SAE 127-2 17.58 15.14 7.02 1.00 10.58 16.58 5.15
(SAE-C) (446,6)
(SAE-C) (446,6) (178,3)(384,6)
(384,6) (25,4) (178,3)(421,2)
(268,8) (25,4)
(130,9) (268,8) (421,2) (130,9)
16.48
4.50 5.38
SAE 152-4
SAE 152-4 18.92
(SAE-D) 18.92
(418,6)
8.36
16.48.86 8.36 17.92
11.92
.866.49
11.92 17.92 6.49
(480,6) (212,3) (21,8) (302,8) (455,2) (164,8)
(114,3) (136,5) (SAE-D) (480,6) (418,6) (212,3) (21,8) (302,8) (455,2) (164,8)
5.32
(135,1)

5.32
(135,1) NOTE: See page 16 for shaft information.
4.50
(114,3) See pages 45-54 for rear drive information.
5.38
(136,5) See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 13
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
M6-M7-M8 F, G, M, N Dimensions GOLD CUP® Series - Open & Closed Circuits

M*F & M*G MOUNTING L1 L2 L3 L4


SAE 127-2 11.19 11.06 4.90 .85
(SAE-C) (284,2) (280,9) (124,5) (21,6)
SAE 152-4 11.59 11.46 5.30 .89
(SAE-D) (294,3) (291,1) (134,6) (22,6)
DRAIN CONN.
SAE-12 STR. THD.
A L3 D1
"D" CASE DRAIN CONN.
.72 3.00 3.00
(18,3) (76,2) (76,2)
SAE-12 STR. THD.

B A
1.56
(39,6)

3.12
(79,2)

4.56
(115,8)
"M*G" ONLY

D2 ALT. DRAIN CONN. 6000 PSI


A L4 SAE-12 STR. THD.
1.44
(36,6)
SAE-
1.50
(38,1)
DIA.
(418 BARS)
L2 5/8-11UNC x
1.30
DEEP
4-BOLT FLG. CONN

L1 8-PLACES (33,0)

M*M & M*N REAR ADAPTER

M*M & M*N DRAIN CONN. 1.30


5/8-11 UNC-2B TAPx DP.
A L3
SAE-12 STR. THD.
D1 4 PLACES AS SHOWN
(33,0)

3.12
(79.2)
1.56
(39.6)

3.94 .72
(99,9) .25 (18.3)
(6.4)
1.44
(36.6)

3.94
(99,9) 5.67
PORTS A & B
(144,0)
"M*N" ONLY 1.50 DIA. 6000 PSI
SAE-
(38.1) (418 BARS)
4-BOLT FLG. CON

D2 ALT. DRAIN CONN.


L4 SAE-12 STR. THD.

A L2 PORT "A"- FAR SIDE


PORT "B"- THIS SIDE
L1 SEE PORT DETAIL

4.50
(114,3)
MOUNTING
MOUNTING
SAE 127-2
L1
13.40
L1 L3 L2
L2
10.14
L4
4.90 .85
L3 L4
SAE 127-2
(SAE-C) (340,4) 13.40 (124,5) 10.14
(257,6) (21,6) 4.90 .85
10.54
(SAE-C) 13.80
SAE 152-4
(SAE-D) (350,5)
(340,4)
(267,7)
5.30 .89
(257,6) (124,5) (21,6)
(134,6) (22,6)

SAE 152-4 13.80 10.54 5.30 .89


(SAE-D) (350,5) (267,7) (134,6) (22,6)

NOTE: See page 16 for shaft information.


4.50
(114,3)
See pages 45-54 for rear drive information.

Parker Hannifin Corporation


Hydraulic Pump Division
14 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
M6-M7-M8 H, V, R, L Motor Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

M*H & M*V TABLE 14

MOUNTING L1 L2 L3 L4 L5 L7
SAE 127-2 13.16 12.80 7.02 1.00 10.58 5.15
(SAE-C) (334,3) (325,1) (178,3) (25,4) (268,8) (130,9)
SAE 152-4 14.50 14.14 8.36 .86 11.92 6.49
(SAE-D) (368,3) (359,2) (212,3) (21,8) (302,8) (164,8)
D CASE DRAIN PORT
H2 CONTROL PRESSURE INLET H1 CONTROL PRESSURE INLET SAE-12 STR. THD.
SAE-8 STR. THD. (FAR SIDE) SAE-8 STR. THD. (NEAR SIDE)
4.50 4.50
L3 (114,3) (114,3)
A ALT. DRAIN CONN.
L7 SAE-12 STR. THD.
.72
(18,3)
3.00
(76,2)
3.00
(76,2)
D1

3.87
(98,3)

B A
1.56
1.16
(39,6)
(29,5)
3.12
(79,2)
3.87 4.56
(98,3) (115,8)
"M*H" ONLY

L4 ALT. DRAIN CONN. D2


1.44
SAE-
1.50
DIA.
6000 PSI
A SAE-12 STR. THD.
(36,6) (38,1) (414 bar)
1.38 4-BOLT FLG. CONN
L5 5/8-11UNC x
8-PLACES (35,1)
DEEP 2-PLACES

L2
L1
M*R & M*L REAR ADAPTER
M*R & M*L
L3
A L7 D1 DRAIN CONN.
1.30
SAE-12 STR. THD. 5/8-11 UNC-2B TAP x DP.
(33,0)
4 PLACES AS SHOWN

3.12
(79.2)
1.56
3.87 .25 (39.6)
(98,3) (6.3) .72
(18.3)

1.44
(36.6)
1.94
3.87
(49,3)
(98,3)

1H
SYSTEM PORT A (FAR SIDE)
5.67 SYSTEM PORT B (NEAR SIDE)
(144,0) 1.50 DIA. 6000 PSI
"M*L" ONLY SAE-
(38.1) (418 BARS)
ALT. DRAIN CONN. D2 4-BOLT FLG. CON
A SAE-12 STR. THD.

H1 CONTROL PRESSURE INLET


L3 SAE-8 STR. THD. (NEAR SIDE)
L2 H2 CONTROL PRESSURE INLET
SAE-8 STR. THD. (FAR SIDE)
L1

TABLE 13

4.50
4.50
(114,3)
MOUNTING L1 L2 L3 L4 L5 L7
(114,3) SAE 127-2 15.14 11.88 7.02 1.00 10.36 5.15
TABLE 13
(SAE-C) (384,6) (301,8) (178,3) (25,4) (263,1) (130,9)
MOUNTING L1 L2 L3 L4 L5 L7
SAE 152-415.14
SAE 127-2 16.48 7.02
11.88 13.22
1.00 10.36 8.36
5.15
.86 11.70 6.49
(SAE-C) (384,6) (301,8) (178,3) (25,4) (263,1) (130,9)
(SAE-D)16.48
SAE 152-4 (418,7)
13.22 8.36 (335,9)
.86 11.70 (212,3)
6.49 (21,8) (397,2) (164,8)
(SAE-D) (418,7) (335,9) (212,3) (21,8) (397,2) (164,8)

4.50
(114,3)
4.50 NOTE: See page 16 for shaft information.
(114,3)
See pages 45-54 for rear drive information.
See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 15
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
For 6-7-8 Pumps & Motors GOLD CUP® Series - Open & Closed Circuits

M*F, M*G, M*H, M*V, P*S, P*X, P*D, P*P, P*V & P*F M*R, M*L, M*M, M*N, P*L & P*R
2.97
2.91
S1 75,4
( 73,9 )
.49
(12,4)
.78
(M10 x 1.5) METRIC THREAD x DEEP
(19,8)
S2 .25
(6,4)
MAX.
.83
(21,1)
1.71
SPLINE LENGTH
S3 (43,4)
4.50
(114,3)
.12
(3,0) 3.18
6.000
5.998 (80,8)
30˚ DIA.
152,40
1.943
( 152,35 )
(49,35) 2.76
DIA.
(70,1)

30˚
6.36
1.7500
1.7494 (161,6)
DIA.
44,45
( 44,43 ( 4.50
.12 (114,3)
(3,0) .06
x 45˚
.31 (1,5)
FOR SAE 152-4
(7,9) 3.18
("D" 4-BOLT) (80,8)
SAE 152-4 ("D" 4 BOLT) SAE 152-4 ("D" 4 BOLT) 6.36
(161,6)
SAE 44-1 4.44
SAE 44-4 (112,8)
("D" KEYED) ("D" SPLINE) 8.88
(225,6)
SHAFT DEGIGNATION
PUMP MODEL CODE SHAFT S1 S2 S3 SHAFT DEGIGNATION
PUMP MODEL CODE
SAE INVOLUTE SPLINE J498-B 1969
EXTERNAL CLASS 1 FLAT ROOT SIDE FIT
SAE 44-1 2.97/2.91 2.64 .438/.437 1.75 8/16 DIA. PITCH
04 (SAE-D Key) (75,4/73,9) (67,0) (11,12/11,10)
SQ. KEY x
(44,4) 30˚ PRESSURE ANGLE
05 13 TEETH
1.7210-1.7160
MAJOR DIA
(43,713/43,586)

2.23 2.23
2.15 2.15 .78
(M10 x 1.5) METRIC THREAD x DEEP
( 56,6
54,6 ) ( 56,6
54,6 ) FOR SAE 127-2 (19,8)

.49
1.19 (12,4)
("C" 2-BOLT)
SPLINE LENGTH
(30,2) SEE NOTE 1 .73
.24 8.50
DIA.
S1 (6,1) 1.75
SPLINE LENGTH (215,9) (18,4)
(44,5) SEE NOTE 2

S2 S3 .09
(2,3)
4.22
3.56
1.386 (107,2)
4.50 (90,4)
(35,20) DIA.
30˚ (114,3)

5.000
4.998
DIA.
30˚ 127,00
1.2500
( 126,95 )
7.12 4.22
1.2494
DIA. (180,8) (107,2)
31,750
.09
( 31,735 )
.06
(2,3) x 45˚
(1,5)
1.30
DIA. .31 NOTES:
(33,0) MIN.
SAE 127-2 ("C" 2-BOLT) (7,9) 1. SPLINE LENGTH ONLY FOR:
SAE 127-2 ("C" 2-BOLT) M*F, M*G, M*H, M*V, P*S, P*X, P*D, P*P, P*V & P*F
SAE 32-1 2. SPLINE LENGTH ONLY FOR:
("C" KEYED) SAE 32-4
M*R, M*L, M*M, M*N, P*L & P*R
("C" SPLINE)
SHAFT DEGIGNATION SHAFT DEGIGNATION
PUMP MODEL CODE SHAFT S1 S2 S3 PUMP MODEL CODE
SAE INVOLUTE SPLINE J498-B 1969
EXTERNAL CLASS 1 FLAT ROOT SIDE FIT
SAE 32-1 2.23/2.15 1.88 .312/.310 1.25/1.22 12/24 DIA. PITCH
02 or 07 (SAE-C) (56,6/54,6) (47,8) (7,92/7,87)
SQ. KEY x LG.
(31,8/31,0) 30˚ PRESSURE ANGLE
SAE 32-1 LONG 3.36/3.28 3.01 .312/.310 2.38/2.35
03 or 08 14 TEETH
1.2293-1.2243
09 or 10 (SAE-C) (85,3/83,3) (76,4) (7,92/7,87)
SQ. KEY x LG.
(60,4/59,7) (31,224/31,097)
MAJOR DIA

Parker Hannifin Corporation


Hydraulic Pump Division
16 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P11-P14 M, F Dimensions GOLD CUP® Series - Open & Closed Circuits

16.28
(413,4) REAR ADAPTER
6.12
(155.4)
B 1.12
(28.4) "D1" DRAIN CONN.
SAE-16 STR. THD.

4.82
(122,4)

5.91
(150,0)

"D2" ALT. DRAIN CONN. 3.13


SAE-16 STR. THD. (79,4)
B 13.60
1.56
(39,7)
5.94 5.94
(345,4) (150,9) (150,9)

1.44
(36,6)

1.31
5/8 -11UNC-2B THREAD x DEEP
.72 (33,3)
8-PLACES

P*M (18,3)

SYSTEM PORT A (FAR SIDE)


SYSTEM PORT B (NEAR SIDE)
1.50 DIA. 6000 PSI
SAE-
(38,1) (414 BAR)
4-BOLT FLG. CONNECTION

P*F
16.51
(419,4)
1.31
15.28 5/8-11UNC-2B THREAD x DEEP
(388,0) 8-PLACES (33,3)
6.12 1.44 1.44
(155.4) (36.4) (36.4)
B 1.12
(28.4)
"D1" ALT. DRAIN CONN.
SAE-16 STR. THD.
.72
3.00 3.00 .72
(18.3) (76.2) (18.3)
(76.2)
A
B

4.82
(122,4)

1.56
(39,6) 3.12
(79,2)

4.82
(122,4)

"D2" ALT. DRAIN CONN.


SAE-16 STR. THD. "D" DRAIN CONNECTION
SAE-1.50 6000 P.S.I.
B (38.1)
DIA.
(414 bar)
SAE-16 STR. THD.

4-BOLT FLG. CONN. (CODE 62)


2-PLACES

NOTE: See page 23 for shaft information.


See pages 45-54 for rear drive information.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 17
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P11-P14 P, V Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

SAE-1.50 6000 P.S.I.


DIA.
(38.1) (415 bar)
4-BOLT FLG. CONN. (CODE 62)
TYPICAL 2-PLACES 1.44

L1 .72
(36,6)
3.00 3.00

B 1.12
(28,4)
L3 "D1" DRAIN CONN.
(18,3) (76,2) (76,2)

SAE-16 STR. THD.

5.83
5.17 (148,0)
(131,3)
B A
1.56
(39,6)
3.12
(79,2)

5.17 4.91
(131,3) (124,7) 5.33
(135,3)

L7
"D2" ALT. DRAIN CONN. 5.56 5.56
B SAE-16 STR. THD. 141,3 ( 141,3 )

1.38
L4 "C" AUXILIARY PUMP INLET
5/8-11UNC-2B x
8-PLACES (35,1)
DEEP

SAE-20 STR. THD.

P*P L2 TABLE 6

PUMP L1 L2 L3 L4 L7
P11P, P14P 19.83 18.31 8.48 15.25 6.38
& (503,8) (465,2) (215,3) (387,4) (162,0)
P*V SAE-1.50
(38.1)
DIA.
6000 P.S.I.
(415 bar)
P11V, P14V

4-BOLT FLG. CONN. (CODE 62)


1.44 2.00

L1 .72
(36,6)
3.00 3.25
(50,8)
1.00

B 1.12
(28,4)
L3 "D1" DRAIN CONN.
(18,3) (76,2) (82,6) (25,4)

SAE-16 STR. THD.

5.83
5.17 (148,0)
(131,3)
B A
1.56 1.75
(39,6) (44,4)
3.50
3.12
(88,9)
(79,2)

5.17 4.91
(131,3) (124,7) 5.33
(135,3)

L7
"D2" ALT. DRAIN CONN. 5.56 5.56
B SAE-16 STR. THD. 141,3 ( 141,3 )

L4 "C" AUXILIARY PUMP INLET


1.38
2.50
(63,5)
DIA.
2500 PSI
(172 BARS)
4-BOLT FLG.

1.19
SAE-20 STR. THD. 5/8-11UNC-2B x DEEP 1/2-13UNC-2B x DEEP
L2 4-PLACES (35,1) 4-PLACES (30,2)

NOTE: See page 23 for shaft information.


See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
18 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P11-P14 S, X Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

"K" AUXILIARY REPLENISH AND


PUMP FILTER RETURN PORT
SAE-12 STR. THD.

L5
L3
B 1.12
"D1" DRAIN CONN.
(28,4) SAE-16 STR. THD.

3.38 R
(85,8)

5.83
5.17 (148,0)
(131,3)

.90
(23,0)
.90
(23,0)
B A
4.91
5.17 (124,7)
6.51
(131,3) (165,4)

L7 "D2" ALT. DRAIN CONN.


B SAE-16 STR. THD.
L4 5.38
(136,5)
5.38
(136,5)
L2
P*S "C"L1
AUXILIARY PUMP INLET
SAE-20 STR. THD. "C" AUXILIARY PUMP INLET
1.44
(36,6)
5.56
141,3
5.56
(141,3 )

.72 1.31
TABLE 7 SAE-20 STR. THD.

P*S (18,3) 5/8 -11UNC-2B THREAD x DEEP


TABLE 7 8-PLACES (33,3)
PUMP L1 L2 L3 PUMP L4 L1 L5L2 L7
L3 L4 L5 L7
24.58 P*S
24.58
P*S 19.75 8.48 15.25 21.19 6.38 1.56
(624,4) 19.75 8.48 15.25 (624,4) 21.19 6.38 (39,7)
21.88 (501,7) (215,3) (387,4) (538.3) (162,0)
21.88 (501,7) (215,3) P*X(387,4)
(555,7)
(538.3) (162,0) 3.13

P*X P*X
(555,7)
"K" AUXILIARY REPLENISH AND
(79,4)

P*X L5
PUMP FILTER RETURN PORT
SAE-12 STR. THD.
SYSTEM PORT A (FAR SIDE)
SYSTEM PORT B (NEAR SIDE)
1.50 DIA. 6000 PSI
SAE-
L3 (38,1) (414 BARS)
B 1.12
"D1" DRAIN CONN. 4-BOLT FLG. CONNECTION
(28,4) SAE-16 STR. THD.

3.38 R
(85,8)

5.83
5.17 (148,0)
(131,3)

.90
(23,0)
.90
(23,0)
B A
5.17 4.91
(131,3) (124,7) 5.33
(135,3)

5.38 5.38
L7 "D2" ALT. DRAIN CONN. (136,5) (136,5)
B L4
SAE-16 STR. THD.
5.56 5.56
141,3 ( 141,3 )
L2
L1
"C" AUXILIARY PUMP INLET
SAE-20 STR. THD.

NOTE: See page 23 for shaft information.


See pages 45-53 for rear drive information.
See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 19
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P11-P14 R, L Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

3.13
(79,4) 1.31
1.56 5/8 -11UNC-2B THREAD x DEEP
(33,3)

P*R & P*LP*R & P*L


(39,7) 8-PLACES

1.44
(36,6)

TABLE 8
TABLE 8
.72
PUMP L1
PUMP L1L2 L2 L3
L3 L4L4 L7 L7 (18,3)

18.31 15.64 8.48 18.31 6.38 SYSTEM PORT A (FAR SIDE)


P*R & P*L
18.31 15.64(397,1)
(465,2) 8.48
(215,3) 18.31(162,0)
(465,2) 6.38
P*R & P*L SYSTEM PORT B (NEAR SIDE)
(465,2) (397,1) (215,3) (465,2) (162,0) SAE-
1.50 DIA. 6000 PSI
(38,1) (414 BARS)
4-BOLT FLG. CONNECTION

EXTERNAL SERVO SUPPLY


L4 REAR ADAPTER
INLET CONN. "G2" 5.15
(NEAR & FAR SIDES) (130,8)
SAE-8 STR. THD.
B "D1" DRAIN CONN.
SAE-16 STR. THD.

5.17
(131,3)

1.73
(43,9)

5.17
(131,3) 5.91
(150,0)
"P*R" ONLY
SHOWN IN PHANTOM

8.08
(205,1)
"P*L" ONLY
1.12 "D2" ALT. DRAIN CONN. SHOWN
B (28,4) SAE-16 STR. THD.

L7
L3
L2 "K" AUXILIARY REPLENISH
(NEAR & FAR SIDES)
L1 SAE-12 STR. THD.

SYSTEM PORT B REF.

5.94
(150,9)
5.56
(141,3)

5.94
5.56 (150,9)
(141,3)

SYSTEM PORT A REF.

NOTE: See page 23 for shaft information.


See pages 45-53 for rear drive information.
See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
20 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
M11-M14 H, V, F, G Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

11-14 MOTOR DIMENSIONS


SAE-1.50 6000 P.S.I.
DIA.
(38.1) (415 bar)
4-BOLT FLG. CONN. (CODE 62)
1.31 2-PLACES
5/8-11 UNC-2B THREAD x DEEP
8-PLACES (33,3)

L4 1.44
3.00
(76.2)
3.00
(76.2)

1.44

B 1.12 L3 "D1" ALT. DRAIN CONN.


SAE-16 STR. THD.
.72
(18.3)
(36.4)
(36.4)
.72
(28.4) (18.3)

"H1" (NEAR SIDE)


"H2" (FAR SIDE)
CONTROL PRESSURE INLET
SAE-8 STR. THD.
2-PLACES
5.17
(131.3)
B A
1.43 1.56
(36.3) (39,6) 3.12
(79,2)

5.17
(131.3)

2.75

B L7 "D2" ALT. DRAIN CONN.


SAE-16 STR. THD.
(69,8)
5.56
141,3
5.56
( 141,3 )
"D" DRAIN CONNECTION
L2 TABLE 15
SAE-12 STR. THD.

L1 MOTOR L1 L2 L3 L4 L7
M11H, M11V 17.79 17.32 8.48 14.56 6.38
M*H & M*V &
M14H, M14V
(451.9) (439.9) (215,3) (369,9) (162,0)

M*F & M*G SAE-1.50


(38.1)
DIA.
6000 P.S.I.
(414 bar)
4-BOLT FLG. CONN. (CODE 62)
1.31 2-PLACES
5/8-11UNC-2B THREAD x DEEP
16.51 8-PLACES (33,3)
(419,4)
3.00 3.00
15.28 (76.2) (76.2)
(388,0)
6.12 1.44 1.44
(155.4) (36.4) (36.4)
B 1.12
(28.4)
"D1" ALT. DRAIN CONN.
SAE-16 STR. THD.
.72 .72
(18.3) (18.3)
A
B

4.82
(122,4)

1.56
(39,6) 3.12
(79,2)

4.82
(122,4)

"D2" ALT. DRAIN CONN.


SAE-16 STR. THD. SHUTTLE ("M*G" ONLY) "D" DRAIN CONNECTION
B SAE-16 STR. THD.

NOTE: See page 23 for shaft information.


See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 21
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
M11-M14 M, N, R, L Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

16.28
(413,4) REAR ADAPTER
6.12
(155.4)
B 1.12
(28.4) "D1" DRAIN CONN.
SAE-16 STR. THD.

4.82
(122,4)

5.91
(150,0)
"M*M" ONLY
SHOWN IN PHANTOM

7.72
(196,1)
"M*N" ONLY
SHOWN
B "D2" ALT. DRAIN CONN.
SAE-16 STR. THD.

13.60
5.94 5.94
(345,4)
(150,9) (150,9)

3.13
(79,4) 1.31
1.56 5/8 -11UNC-2B THREAD x DEEP

M*M & M*N (39,7) 8-PLACES (33,3)

1.44
(36,6)

.72

M*R & M*L


(18,3)

SYSTEM PORT A (FAR SIDE)


SYSTEM PORT B (NEAR SIDE)
1.50 DIA. 6000 PSI
SAE-
(38,1) (414 BARS)
4-BOLT FLG. CONNECTION
ALTERNATE EXTERNAL SERVO SUPPLY
INLET CONN. "G2"
SAE-8 STR. THD.
B "D1" DRAIN CONN.
5.15
(130,8)
SAE-16 STR. THD.

5.17
(131,3)

1.73
(43,9)

5.17
(131,3) 5.91
(150,0)
"M*R" ONLY
SHOWN IN PHANTOM

7.72
(196,1)
"M*L" ONLY

B L7 "D2" ALT. DRAIN CONN.


SAE-16 STR. THD.
SHOWN

L3
L2
L1 SYSTEM PORT B REF.
REAR ADAPTER
1.12 TABLE 16
(28,4)
TABLE MOTOR
16
L1 L2 L3 L4 L7
5.94
M11R, M11L
MOTOR
&
M14R, M14L
18.31
L1
(465,2)
15.64
(397,1)
L2 8.48
(215,3) L314.56
(369,9) L4
6.38
(162,0) L7
5.56
(150,9) M11R, M11L 18.31 15.64 8.48 14.56 6.38
( 141,3
) & (465,2) (397,1) (215,3) (369,9) (162,0)
M14R, M14L

5.94
5.56 (150,9)
( 141,3
)
NOTE: See page 23 for shaft information.
See pages 45-54 for rear drive information.
See appropriate controls mounting starting on page 34.

SYSTEM PORT A REF.

Parker Hannifin Corporation


Hydraulic Pump Division
22 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
For 11-14 Pumps & Motors GOLD CUP® Series - Open & Closed Circuits

M*F, M*G, M*H, M*V, P*S, P*X, P*P, P*V & P*F M*R, M*L, M*M, M*N, P*L & P*R

2.97
2.90 2.97
75,4 2.90
73,7 .625 75,4
.605 73,7
15,88
1.50
15,37 1.62
SPLINE LENGTH
S1
SPLINE LENGTH (41,1) SEE NOTE 2
(38,1) SEE NOTE 1 .36
(9.1) .09
(2,3)

S3
.09
(2,3)
6.500
6.498
DIA.
165.1
1.941
165.0 2.75 NECK (49,30)
(69.8) SEE NOTE 1
DIA.
30˚
30˚

1.7500
1.7495
DIA.
44,45
44,43
.06
x 45˚
(1,5)

SAE 165-4 ("E" 4-BOLT) SAE 165-4 ("E" 4-BOLT)


SAE 165-4 ("E" 4-BOLT) SAE 44-4 SAE 165-4SAE
("E"44-1
4-BOLT)
SAE 44-4 SAE 44-1
("E" KEYED)
("E" SPLINE)
("E" SPLINE) ("E" KEYED)
SHAFT DEGIGNATION SAE INVOLUTE SPLINE DATA J498B 1969
SHAFT DEGIGNATION
PUMP MODEL CODE SAE INVOLUTE SPLINESHAFT
DATA J498B 1969
DEGIGNATION
PUMP MODEL CODE
FLAT ROOT SIDE FIT EXTERNAL CLASS 1
PUMP MODEL CODE SHAFT S1 S3

NOTES:
VIEW B-B 03 or 08
8/16 PITCH
30˚ PRESSURE ANGLE
13 TEETH
1.7210-1.7160
FLAT ROOT SIDE FIT EXTERNAL CLASSSAE144-1
8/16 PITCH
02 or 07 (SAE-E)
SAE 44-1 LONG
2.97/2.90
(75,4/73,7)
3.97/3.90
.437/.435
(11,10/11.05)
.437/.435
SQ. KEY x LG.
1.50
(38,1)
2.50
30˚ PRESSURE ANGLE 09 or 10
1. SPLINE LENGTH AND NECK ONLY FOR: MAJOR DIA. SQ. KEY x LG.
(43,713-43,586) (SAE-E) (100,8/99,1) (11,10/11.05) (63,5)
M*F, M*G, M*H, M*V, P*S, P*X, P*P, P*V & P*F
2. SPLINE LENGTH ONLY FOR:
03 or 08 13 TEETH
M*R, M*L, M*M, M*N, P*L & P*R 1.7210-1.7160
MAJOR DIA.
(43,713-43,586)

SHAFT DEGIGNATION
PUMP MODEL CODE SHAFT S1 S3
SAE 44-1 2.97/2.90 .437/.435 1.50
02 or 07 (SAE-E) (75,4/73,7) (11,10/11.05)
SQ. KEY x LG.
(38,1)
SAE 44-1 LONG 3.97/3.90 .437/.435 2.50
09 or 10 (SAE-E) (100,8/99,1) (11,10/11.05)
SQ. KEY x LG.
(63,5)

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 23
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P24-P30 M, F Dimensions GOLD CUP® Series - Open & Closed Circuits

3.82
(97,0)
.88 1.91
(22,3) (48,5)
L1 1.50
3/4-10UNC x DEEP
L2 8-PLACES (38,1)

C 10.92
1.75
(277,5)
"D1" SAE-20 STR. THD. (44,4)
CASE DRAIN

SYSTEM PORT A (FAR SIDE)


7.31 6.18 SYSTEM PORT B (NEAR SIDE)
(185,7) 2.00 6000 PSI
(157,0) SAE- DIA.
(50,8) (414 bar)
4-BOLT FLG. CONN

BG
6.44
6.18
(163,6)
(157,0) 6.84
K (173,7)

7.31
(185,7)

"D2" SAE-20 STR. THD.


C 1.25 CASE DRAIN 1.25
REAR ADAPTER
(31,7) (31,8)

7.86
(199,6) 6.44
(163,6)

PUMP L1 L2
7.86 6.44
(199,6)
(163,6) P24M 23.33 18.09
PUMP L1
(SHOWN) L2 (592,6) (459,4)
P24M 23.33 18.09
OVERHUNG SUPPORT POINT (592,6) (459,4)
(SHOWN) 24.33 19.09
7/8"-9 UNC x 1.25 DEEP
(31,8) P30M24.33 19.09 (618,0) (484,8)
P*M P30M (618,0) (484,8)

3.82
(97,0)

P*F .88
(22,3)
1.91
(48,5) 3/4-10 UNC x
8-PLACES
1.50
(38,1)
DEEP MOTOR L1
MOTOR L2
L1 L2
P24F 21.61 20.46
(SHOWN) (548,8) (519,6)
1.75
(44,4)
P24F22.61 21.46 21.61 20.46
P30F (574,2) (545,0)
(SHOWN) (548,8) (519,6)
SYSTEM PORTS A & B
SAE- 2.00
DIA.
6000 PSI
22.61 21.46
(50,8) (414 bar)
4-BOLT FLG. CONN
P30F (574,2) (545,0)
L1
L2
7.86 7.86
(199,6) (199,6)
10.92
C (277,5) "D1" SAE-20 STR. THD. 4.38 4.38
ALTERNATE CASE DRAIN (111,2) (111,2)

7.31
(185,7)
B A
6.18
(157,0)

6.18
(157,0) 6.81
5.52
(140.1) (173,0)
"M*F" ONLY "M*G" ONLY
7.31 SHOWN IN PHANTOM SHOWN

(185,7)

CASE DRAIN
"D2" SAE-20 STR. THD.
"D" SAE-16 STR. THD.
C ALTERNATE CASE DRAIN

NOTE: See page 32 for shaft information.

Parker Hannifin Corporation


Hydraulic Pump Division
24 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P24-P30 P Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

L3
"D1" SAE-20 STR. THD.
CASE DRAIN

TABLE 10

6.44
PUMP L1 L2 L3 L4 L7
(163,6) P24P 23.70 18.08 16.34 18.80
(SHOWN) (602,1) (459,4) (414,9) (477,4) 8.14
(206,7)
24.70 19.08 17.34 19.80
P30P (484,7)
(627,5) (440,3) (502,8)
1.66
(42,2)

3.82
6.44
(97,0)
(163,6) .88 1.91
(22,3) (48,5)
1.50
3/4-10UNC x DEEP
(38,1)
8-PLACES

1.75
"H1" SAE-12 STR THD (44,4)
PUMP SERVO & REPLEN. SUPPLY
1.25 INLET FROM EXTERNAL FILTER
(31,7)

L1 SYSTEM PORT A (FAR SIDE)


SYSTEM PORT B (NEAR SIDE)
L2 SAE-
2.00
DIA.
6000 PSI
C 10.92 (50,8) (414 bar)
4-BOLT FLG. CONN
(277,5)

7.31 6.08
T
(185,7) (154,4) P
O
K

6.18
(157,0)

B A

6.18 3.26
4.75 (82,9)
(157,0) K
(120,7)

7.31 G
(185,7)

"G" SAE-12 STR THD


AUX. PUMP (SERVO & REPLEN.) 45˚
OUTLET TO EXTERNAL FILTER
L7
C 1.82
"D2" SAE-20 STR. THD.
(46,2)
CASE DRAIN 7.15 7.15
L4 (181,6) (181,6)

"K" SAE-32 STR THD


OPTIONAL-REPLEN. PUMP SUPPLY INLET

1.06
1/2 -13UNC x DEEP
4-PLACES (26,9)

1.53
(38,9)
3.06
(77,7)

2.00 DIA. 3000 PSI


SAE-
(50,8) (207 bar)
4-BOLT FLG. CONN
AUX. PUMP (SERVO & REPLEN.) SUPPLY INLET

"C"
.84
(21,3)

P*P 1.68
(42,7)

NOTE: See page 32 for shaft information.


See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 25
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P24-P30 X Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

L3
"D1" SAE-20 STR. THD.
CASE DRAIN REAR ADAPTER

TABLE 11

6.44
PUMP L1 L2 L3 L4 L7
(163,6) P24X 22.83 18.08 16.34 18.80
(SHOWN) (579,9) (459,4) (414,9) (477,4)
8.14
(206,7)
23.83 19.08 17.34 19.80
P30X (484,7) (440,3) (502,8)
(605,3)
1.66
(42,2)

3.82
6.44
(97,0)
(163,6) .88 1.91
(22,3) (48,5)
1.50
3/4-10UNC x DEEP
8-PLACES (38,1)

1.75
"H1" SAE-12 STR THD (44,4)
PUMP SERVO & REPLEN. SUPPLY
1.25 INLET FROM EXTERNAL FILTER
(31,7)

L1 SYSTEM PORT A (FAR SIDE)


SYSTEM PORT B (NEAR SIDE)
L2 SAE-
2.00
DIA.
6000 PSI
C 10.92 (50,8) (414 bar)
4-BOLT FLG. CONN
(277,5)

7.31 6.08
(185,7) (154,4)

G
6.18
(157,0)

B A

6.18
(157,0) 4.75
(120,7) K
O
P
T
7.31
(185,7)

7.15 7.15
L7 (181,6) (181,6)
C
"D2" SAE-20 STR. THD.
CASE DRAIN
L4

1.06
1/2 -13UNC x DEEP
4-PLACES (26,9)

1.53
(38,9)
3.06
(77,7)

2.00 DIA. 3000 PSI


SAE-
(50,8) (207 bar)
4-BOLT FLG. CONN
AUX. PUMP (SERVO & REPLEN.) SUPPLY INLET

"C"
.84
(21,3)

P*X 1.68
(42,7)
NOTE: See page 32 for shaft information.
See pages 45-53 for rear drive information.
See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
26 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P24-P30 S Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

L3
"D1" SAE-20 STR. THD.
CASE DRAIN REAR ADAPTER

6.44
(163,6)

1.66
(42,2)

3.82
6.44
(97,0)
(163,6) .88 1.91
(22,3) (48,5)
1.50
3/4-10UNC x DEEP
8-PLACES (38,1)

1.75
"H1" SAE-12 STR THD (44,4)
PUMP SERVO & REPLEN. SUPPLY
1.25 INLET FROM EXTERNAL FILTER
(31,7)

L1 SYSTEM PORT A (FAR SIDE)


SYSTEM PORT B (NEAR SIDE)
L2 SAE-
2.00
DIA.
6000 PSI
C 10.92 (50,8) (414 bar)
4-BOLT FLG. CONN
(277,5)

7.31 6.08
(185,7) (154,4)

G
6.18
(157,0)

B A

6.18
(157,0)
K
O
P
T
7.31
(185,7)

9.89

L7 (251,3)

C
"D2" SAE-20 STR. THD.
CASE DRAIN 7.15 7.15
(181,6) (181,6)

TABLE 9

PUMP L1 L2 L3 L7
P24S 22.83 18.09 16.34
(SHOWN) (579,9) (459,4) (414,9) 8.14
(206,7)
23.83 19.09 17.34
P30S
(605,3) (484,8) (440,3)

"D3" DRAIN CONNECTION


SAE-16 STR. THD. NOTE: See page 32 for shaft information.
P*S See pages 45-53 for rear drive information.
See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 27
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P24-P30 R, L Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

L3 REAR ADAPTER
"D1" SAE-20 STR. THD.
CASE DRAIN

TABLE 12

6.44
PUMP L1 L2 L3 L7
(163,6) P24 23.33 18.08 16.34
(SHOWN) (592,6) (459,4) (414,9) 8.14
(206,7)
24.33 19.08 17.34
P30
(618,0) (484,7) (440,3)
1.66
(42,2)

3.82
6.44
(97,0)
(163,6) .88 1.91
(22,3) (48,5)
1.50
3/4-10UNC x DEEP
8-PLACES (38,1)

1.75
"H1" SAE-12 STR THD (44,4)
PUMP SERVO & REPLEN. SUPPLY
1.25 INLET FROM EXTERNAL FILTER
(31,7)

L1 SYSTEM PORT A (FAR SIDE)


SYSTEM PORT B (NEAR SIDE)
L2 SAE-
2.00
DIA.
6000 PSI
10.92 (50,8) (414 bar)
(277,5) 4-BOLT FLG. CONN

7.31 6.08
(185,7) (154,4)

6.18
(157,0)
B
B A
BG
6.44
6.18
(163,6)
(157,0) 9.89
K (251,3)
"P*L" ONLY
SHOWN
7.31
(185,7)
7.72
(196,2)
"P*R" ONLY
SHOWN IN PHANTOM

L7
"D2" SAE-20 STR. THD.
CASE DRAIN
7.15 7.15
(181,6) (181,6)

1.25
(31,8)

OPTIONAL
"K" SAE-16 STR THD
REPLEN. SUPPLY INLET

OVERHUNG SUPPORT POINT


1.25
7/8"-9 UNC x DEEP
(31,8)

NOTE: See page 32 for shaft information.


P*R & P*L See pages 45-54 for rear drive information.
See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
28 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
M24-M30 H, V, F, G Dimensions (Less Controls) GOLD CUP® Series - Open & Closed Circuits

3.82
(97,0)
.88 1.91
(22,3) 1.50
(48,5) 3/4-10 UNC x DEEP
8-PLACES (38,1) TABLE 17

MOTOR L1 L2 L3 L7
M*H & M*V 1.75
(44,4)
TABLE 17

MOTOR L1 L2
M24 L3 L7
21.61 20.46 17.80
M24 21.61 20.46
(SHOWN) 17.80 (548,8) (519,6) (452,0)
(452,0)
8.14
(SHOWN) (548,8) (519,6) 8.14
SYSTEM PORTS A & B (206,7)
SAE- 2.00 6000 PSI 22.61
(206,7) 21.46 18.80
DIA.
M30
22.61 M30
21.46 18.80
(545,0)
(50,8) (414 bar) (574,2) (545,0) (477,4) (574,2) (477,4)
4-BOLT FLG. CONN

L1
L2
7.15 7.15
(181,6) (181,6)
10.92
(277,5) "D1" SAE-20 STR. THD. 4.38 4.38
ALTERNATE CASE DRAIN (111,2) (111,2)

7.31
(185,7)
B A
6.18
(157,0)

2.31
6.18 (58,7)
(157,0) 6.81
5.45
(138,4) (173,0)
"M*V" ONLY "M*H" ONLY
7.31 SHOWN IN PHANTOM SHOWN

(185,7)

CASE DRAIN
L7 "D2" SAE-20 STR. THD. "D" SAE-16 STR. THD.
ALTERNATE CASE DRAIN CONTROL PRESSURE INLET
"H1" SAE-4 STR THD (NEAR SIDE)
"H2" SAE-4 STR THD (FAR SIDE)
L3

3.82
(97,0)
.88 1.91
(22,3) 1.50
(48,5) 3/4-10 UNC x DEEP
8-PLACES (38,1)
MOTOR L1 L2
M*F & M*G 1.75
(44,4) MOTOR L1
M24
L2
(SHOWN)
21.61
(548,8)
20.46
(519,6)
M24 21.61 20.46
(SHOWN) (548,8) (519,6) 22.61 21.46
SYSTEM PORTS A & B M30
SAE- 2.00
DIA.
6000 PSI
22.61 21.46 (574,2) (545,0)
(50,8) (414 bar) M30 (574,2) (545,0)
4-BOLT FLG. CONN

L1
L2
7.86 7.86
(199,6) (199,6)
10.92
(277,5) "D1" SAE-20 STR. THD. 4.38 4.38
ALTERNATE CASE DRAIN (111,2) (111,2)

7.31
(185,7)
B A
6.18
(157,0)

6.18
(157,0) 6.81
5.52
(140.1) (173,0)
"M*F" ONLY "M*G" ONLY
7.31 SHOWN IN PHANTOM SHOWN

(185,7)

CASE DRAIN
"D2" SAE-20 STR. THD.
"D" SAE-16 STR. THD.
ALTERNATE CASE DRAIN

NOTE: See page 32 for shaft information.


See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 29
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
M24-M30 M, N Dimensions GOLD CUP® Series - Open & Closed Circuits

M*M & M*N PUMP L1 L2


M24 23.33 18.09
(SHOWN) (592,6) (459,4)
1.50
3/4-10UNC x DEEP
24.33 19.09 8-PLACES (38,1)
M30 (618,0) (484,8)
3.82
(97,0)
.88 1.91
(22,3) (48,5)
L1
L2
10.92
1.75
(277,5)
"D1" SAE-20 STR. THD. (44,4)
CASE DRAIN

SYSTEM PORT A (FAR SIDE)


7.31 6.18 SYSTEM PORT B (NEAR SIDE)
(185,7) 2.00 6000 PSI
(157,0) SAE- DIA.
(50,8) (414 bar)
4-BOLT FLG. CONN

BG
6.44
6.18
(163,6)
(157,0) 6.84
K (173,7)
"M*M" ONLY
SHOWN IN PHANTOM
7.31
(185,7) 8.13
(206,5)
"M*N" ONLY
SHOWN

"D2" SAE-20 STR. THD.


1.25 CASE DRAIN 1.25
REAR ADAPTER
(31,7) (31,8)

7.86
(199,6) 6.44
(163,6)

7.86 6.44
(199,6)
(163,6)

OVERHUNG SUPPORT POINT


1.25
7/8"-9 UNC x DEEP
(31,8)

NOTE: See page 32 for shaft information.


See pages 45-54 for rear drive information.

Parker Hannifin Corporation


Hydraulic Pump Division
30 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
M24-M30 R, L Dimensions GOLD CUP® Series - Open & Closed Circuits

TABLE 18

M*R & M*L PUMP L1 L2 L7 "H1" SAE-6 STR THD (NEAR SIDE)
"H2" SAE-6 STR THD (FAR SIDE)
M24 23.33 18.09
CONTROL PRESSURE INLET
(SHOWN) (592,6) (459,4) 8.14
1.50
(206,7) 3/4-10UNC x DEEP
24.33 19.09 8-PLACES (38,1)
M30 (618,0) (484,8)
3.82
"D1" SAE-20 STR. THD. (97,0)
CASE DRAIN .88 1.91
(22,3) (48,5)
L1
L2
10.92 2.00
(50,7) 1.75
(277,5)
(44,4)

SYSTEM PORT A (FAR SIDE)


7.31 6.18 SYSTEM PORT B (NEAR SIDE)
(185,7) 2.00 6000 PSI
(157,0) SAE- DIA.
(50,8) (414 bar)
4-BOLT FLG. CONN

BG
6.44
6.18
(163,6)
(157,0) 6.84
K (173,7)
"M*R" ONLY
SHOWN IN PHANTOM
7.31
(185,7) 8.13
(206,5)
"M*L" ONLY
SHOWN

L7
"D2" SAE-20 STR. THD.
1.25 CASE DRAIN 1.25
REAR ADAPTER
(31,7) (31,8)

7.15
(181,6) 6.44
(163,6)

7.15
6.44
(181,6)
(163,6)

OVERHUNG SUPPORT POINT


1.25
7/8"-9 UNC x DEEP
(31,8)

NOTE: See page 32 for shaft information.


See pages 45-54 for rear drive information.
See appropriate controls mounting starting on page 34.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 31
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
For 24-30 Pumps & Motors GOLD CUP® Series - Open & Closed Circuits

M*F, M*G, M*H, M*V, P*S, P*X, P*P & P*F M*R, M*L, M*M, M*N, P*L & P*R
SAE 177-4
SAE F
1.06 3.47 3.47
DIA. THRU 3.41 3.41
(26,9)
2.00
88,1 88,1 S1
DIA. S'FACE (FAR SIDE) 86,6 86,6
(50,8)
4 PLACES
.61
(15,5)
.25
(6,2)

1.75 2.12
SPLINE LENGTH SPLINE LENGTH
SEE NOTE 1 (44,4) (53,8) SEE NOTE 2
S3

1.9994
DIA.
50,80
50,78
9.75 2.75
DIA.
(247,6) (69,8)
7.000
SQ. 6.998
DIA. 2.218
177,80 2.212
4.87 177,75 56,34
(123,7) 56,18
TYP.
.32 .12
x 45˚
(8,1) (3,0)
.12 .06
x 45˚ x 45˚
(3,0) (1,5)
SAE 177-4 ("F" 4-BOLT)
(M16 x 2) METRIC THREAD x
1.00
DEEP SAE 177-4 SAE
("F"50-4
4-BOLT) SAE 177-4 ("F" 4-BOLT)
(25,4) SAE
("F" 50-4
SPLINE) SAE 50-1
("F" SPLINE) ("F" KEYED)
NOTES: SHAFT DEGIGNATION
SHAFT DEGIGNATION
CODESIDE FITSAE
SAE INVOLUTE SPLINE DATAINVOLUTE
J498-B 1969 SPLINE DATA J498-B 1969
SHAFT DEGIGNATION
1. SPLINE LENGTH AND NECK ONLY FOR:
PUMP MODEL CODE
PUMP MODEL
FLAT ROOT EXTERNAL CLASS-1
PUMP MODEL CODE SHAFT S1 S3
3.47/3.41 .500/.498 2.25
M*F, M*G, M*H, M*V, P*S, P*X, P*P & P*F
03 or 08
8/16 PITCH
30˚ PRESSURE ANGLE
FLAT ROOT SIDE FIT EXTERNAL CLASS-102 or 07 SAE 50-1
(SAE-F) (88,1/86,6) (12,70/12.65)
SQ. KEY x LG.
(57,1)
2. SPLINE LENGTH ONLY FOR:
M*R, M*L, M*M, M*N, P*L & P*R
15 TEETH 8/16 PITCH 09 or 10
SAE 50-1 LONG 5.35/5.29 .500/.498
SQ. KEY x LG.
4.13
1.9710-1.9660/ (50,063-49,936) MAJOR DIA. (SAE-F) (12,70/12.65)
03 or 08 30˚ PRESSURE ANGLE (135,9/134,4) (104,9)

15 TEETH
1.9710-1.9660/ (50,063-49,936) MAJOR DIA.

SHAFT DEGIGNATION
PUMP MODEL CODE SHAFT S1 S3
SAE 50-1 3.47/3.41 .500/.498 2.25
02 or 07 (SAE-F) (88,1/86,6) (12,70/12.65)
SQ. KEY x LG.
(57,1)
SAE 50-1 LONG 5.35/5.29 .500/.498 4.13
09 or 10 (SAE-F) (135,9/134,4) (12,70/12.65)
SQ. KEY x LG.
(104,9)

Parker Hannifin Corporation


Hydraulic Pump Division
32 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
®
GOLD CUP Valve Block GOLD CUP® Series - Open & Closed Circuits

VB INDIVIDUAL ("B" SIDE) COMPENSATOR VENT CONN. "V" COMMON COMPENSATOR VENT CONN.
SAE-4 STR.THD. SAE-4 STR. THD.

VA INDIVIDUAL ("A" SIDE)


COMPENSATOR VENT CONN.
SAE-4 STR. THD.

KG REPLENISHING PRESS. GAGE CONN.


SAE-6 STR. THD.

ACCESS PORT PILOT RELIEF VALVE


SAE-3 STR.THD. COMPENSATOR ADJUSTMENT
(UNDER PLUG) 2000 PSI PER TURN
150 PSI PER TURN

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 33
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


CONTROL PUMP ROTARY SERVO PORT CONTROL PUMP ROTARY SERVO PORT
OPTION FIG. ROT. INPUT SHAFT ROTATION "A" OPTION FIG. ROT. INPUT SHAFT ROTATION "A"

1 CW CCW INLET 2 CW CW INLET


"10*" "10*"
1 CCW CW INLET 2 CCW CCW INLET

SEE ROTARY SERVO SEE ROTARY SERVO


SHAFT DETAIL SHAFT DETAIL
L7 L7
SEE TABLES 1-18 SEE TABLES 1-18

F O
F

F F
O

1.40 1.40
(35,6) (35,6)
SCREW ADJ. (CW ROT.)
MIN. VOLUME STOP (CW ROT.) MIN. VOLUME STOP (CCW ROT.) MIN. VOLUME STOP (CW ROT.)
SCREW ADJ. (CCW ROT.) SCREW ADJ. (CCW ROT.)

FIGURE -1 .25 .32


.45
(11,4) FIGURE -2
1/4-20UNC TAP x DEEP
(6,4) (8,1)

ROTARY SERVO SHAFT DETAIL

.513
SEE ROTARY SERVO .508 SEE ROTARY SERVO
MAJOR DIA. KNURL
SHAFT DETAIL 13.03 SHAFT DETAIL
( 12.90 ) (32 TEETH PER INCH)

.45 .45
(11,5) L7 L7 (11,5)
SEE TABLES 1-18 SEE TABLES 1-18

"Y" "X"
F O
F 2.50
(63,5)

2.50
(63,5) F
O F

"X" "Y"

1.40 MIN. VOLUME STOP (CCW ROT.) 1.40


1.00 MAX. VOLUME STOP (CW ROT.) 1.00
(35,6) (35,6)
1.00 (25,4) (25,4) 1.00
MIN. VOLUME STOP (CCW ROT.)
MAX. VOLUME STOP (CCW ROT.) (25,4) (25,4)
MAX. VOLUME STOP (CW ROT.)
MIN. VOLUME STOP (CW ROT.)

FIGURE -1 FIGURE -2

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME
PRESSURE SIGNAL TO: PRESSURE SIGNAL TO:
CONTROL PUMP PORT CONTROL PUMP PORT
OPTION FIG. ROT. 1/8-27 N.P.T.F. 1/8-27 N.P.T.F. OPTION FIG. ROT. 1/8-27 N.P.T.F. 1/8-27 N.P.T.F.
"A" "A"
PORT "X" PORT "Y" PORT "X" PORT "Y"
1 CW MAX. VOL. MIN. VOL. INLET 2 CW MIN. VOL. MAX. VOL. INLET
"2A*" "2A*"
1 CCW MIN. VOL. MAX. VOL. INLET 2 CCW MAX. VOL. MIN. VOL. INLET

Parker Hannifin Corporation


Hydraulic Pump Division
34 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME
PRESSURE SIGNAL ROTARY SERVO PORT PORT PRESSURE SIGNAL ROTARY SERVO PORT PORT
CONTROL PUMP CONTROL PUMP
OPTION FIG. TO SAE-4 INPUT SHAFT OPTION FIG. TO SAE-4 INPUT SHAFT
ROT. "A" "B" ROT. "A" "B"
STR. THD. PORT: ROTATION STR. THD. PORT: ROTATION
1 CW "X" CCW INLET OUTLET 2 CW "Y" CW INLET OUTLET

1 CCW "Y" CW INLET OUTLET 2 CCW "X" CCW INLET OUTLET


"2H*" "2H*"
1 CW "Y" CW OUTLET INLET 2 CW "X" CCW OUTLET INLET

1 CCW "X" CCW OUTLET INLET 2 CCW "Y" CW OUTLET INLET

SEE ROTARY SERVO SEE ROTARY SERVO


SHAFT DETAIL SHAFT DETAIL

.47
(12,0) L7 L7
SEE TABLES 1-18 SEE TABLES 1-18

"Y" "X"
2.47
F O
F

(62,7)

2.47
F
O F (62,7)
"X" "Y"

1.40 MAX. VOLUME STOP 1.40


1.00 1.00
(35,6) (35,6)
1.00 (25,4) (25,4) 1.00
(25,4) (25,4)
MAX. VOLUME STOP TRIMMER ADJ. MAX. VOLUME STOP
.45
(11,4)
.25 .32
1/4-20UNC TAP x DEEP

FIGURE -1
(6,4) (8,1) FIGURE -2
ROTARY SERVO SHAFT DETAIL

SEE ROTARY SERVO .513 SEE ROTARY SERVO


.508 SHAFT DETAIL
SHAFT DETAIL MAJOR DIA. KNURL
13.03
( 12.90 ) (32 TEETH PER INCH) TRIMMER ADJ.
L7 L7
SEE TABLES 1-18 SEE TABLES 1-18

F O
F

F F
O

1.40 MAX. VOLUME STOP 1.40


(35,6) TRIMMER ADJ. MAX. VOLUME STOP (35,6)
MAX. VOLUME STOP

FIGURE -1 FIGURE -2
-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION
CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME
ROTARY SERVO PORT PORT ROTARY SERVO PORT PORT
CONTROL PUMP CONTROL PUMP
OPTION FIG. INPUT SHAFT OPTION FIG. INPUT SHAFT
ROT. "A" "B" ROT. "A" "B"
ROTATION ROTATION
1 CW CCW INLET OUTLET 2 CW CW INLET OUTLET

1 CCW CW INLET OUTLET 2 CCW CCW INLET OUTLET


"4A*" "4A*"
1 CW CW OUTLET INLET 2 CW CCW OUTLET INLET

1 CCW CCW OUTLET INLET 2 CCW CW OUTLET INLET

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 35
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME
ROTARY SERVO PORT PORT ROTARY SERVO PORT PORT
CONTROL PUMP CONTROL PUMP
OPTION FIG. INPUT SHAFT OPTION FIG. INPUT SHAFT
ROT. "A" "B" ROT. "A" "B"
ROTATION ROTATION
1 CW CCW INLET OUTLET 2 CW CW INLET OUTLET

1 CCW CW INLET OUTLET 2 CCW CCW INLET OUTLET


"5A*" "5A*"
1 CW CW OUTLET INLET 2 CW CCW OUTLET INLET

1 CCW CCW OUTLET INLET 2 CCW CW OUTLET INLET

SEE ROTARY SERVO


SHAFT DETAIL
SEE ROTARY SERVO
SHAFT DETAIL
NULL ADJ. 4.10 TRIMMER ADJ. MAX. VOLUME STOP
SCREW (104,0) L7
SEE TABLES 1-18 4.30
L7
SEE TABLES 1-18 (109,3)
MARYSVILLE , OHIO U.S.A.

ASS'Y NO.

5.02
SERIAL NO.

ELEC. RATINGS: L = 1.5 mh MAX.


I = 330 ma MAX. V = 10.56 VOLTS D.C. MAX.
HAZARDOUS LOCATION SUITABILITY:
1. NONINCENDIVE CLASS I, DIVISION 2,
GROUPS A, B, C, AND D.

(127,6)
2. CLASS II, DIVISION 2, GROUPS F AND G.
WARNING- DO NOT DISCONNECT
WHILE CIRCUIT IS LIVE UNLESS
LOCATION IS KNOWN TO BE
NONHAZARDOUS.
033-91428-B

033-91428-B
NONHAZARDOUS.

5.02
LOCATION IS KNOWN TO BE
WHILE CIRCUIT IS LIVE UNLESS
WARNING- DO NOT DISCONNECT
2. CLASS II, DIVISION 2, GROUPS F AND G.
GROUPS A, B, C, AND D.
1. NONINCENDIVE CLASS I, DIVISION 2,
HAZARDOUS LOCATION SUITABILITY:

(127,6)
V = 10.56 VOLTS D.C. MAX. I = 330 ma MAX.
L = 1.5 mh MAX. ELEC. RATINGS:

SERIAL NO.

ASS'Y NO.

MARYSVILLE , OHIO U.S.A.

4.30 MAX. VOLUME STOP


(109,3) TRIMMER ADJ.
.56 4.10 NULL ADJ.
MAX. VOLUME STOP (104,0) SCREW
FIGURE -1 (14,2)
.49
.3760
.3755
(12,5) FIGURE -2
DIA.
INPUT (9,550)
A B CCW (9,538)
+ 19˚ CCW
CURRENT AT FULL DISPL. (MECH.
STOP) .31
350 MA. NOM. DIA. WITH .20 WIDE FLAT
COIL RESISTANCE (7,9)
25 NOM. A O A+
POLARITY
WITH ELECTRICAL POLARITY AS SHOWN
O
INPUT SHAFT WILL ROTATE CCW
CW 19˚ CW .15
ELECTRICAL INPUT (MECH. (3,8)
.390
ECT. RECEPTACLE CONN. 5/8-24UNEF x MAX. STOP)
ATING CONN. HALF, MS3106E-10SL-4S)
(9,91) MANUAL OVERRIDE DETAIL
TO OPERATE, DISCONNECT OIL
SUPPLY TO STROKER SEE ROTARY SERVO
SEE ROTARY SERVO 50in/lbs TORQUE. SHAFT DETAIL
SHAFT DETAIL "Z" BRAKE ACTUATOR PORT DO NOT EXCEED
L7 (6 N.m)
SAE-6 STR. THD. 4.30
NULL ADJ. 4.10 TRIMMER ADJ. MAX. VOLUME STOP (109,3)
SCREW (104,0) .59
(15,1) L7 .45
(11,4)

2.47
L8
(62,7)

2.47
(62,7)

MAX. VOLUME STOP


.45
(11,4) TRIMMER ADJ. .59
4.30 4.10 NULL ADJ.
"Z" BRAKE ACTUATOR PORT (15,1) SCREW
(109,3) MAX. VOLUME STOP (104,0)
SAE-6 STR. THD.
FIGURE -1 FIGURE -2

-B- CONTROL MTG. POSITION SERIES SIZE L7 L8 -A- CONTROL MTG. POSITION
6, 7 & 8 5.15
CONTROL SPRING OFF-SET TO MIN, VOLUME (SAE 127-2) (130,9) CONTROL SPRING OFF-SET TO MIN, VOLUME
6.20
ROTARY SERVO 6, 7 & 8 6.49 (157,4) ROTARY SERVO
CONTROL PUMP PORT PORT CONTROL PUMP PORT PORT
OPTION FIG. INPUT SHAFT (SAE 152-4) (164,8) OPTION FIG. INPUT SHAFT
ROT. "A" "B" ROT. "A" "B"
ROTATION ROTATION
6.38 6.77
CW 11 & 14 (171,9) CW
1 CCW INLET OUTLET (162,0) 2 CW INLET OUTLET
CCW INLET OUTLET 8.14 8.64 CCW INLET OUTLET
"5C*" 1 CW 24 & 30 "5C*" 2 CCW
(206,7) (219,4)
1 CW CW OUTLET INLET 2 CW CCW OUTLET INLET

1 CCW CCW OUTLET INLET 2 CCW CW OUTLET INLET

Parker Hannifin Corporation


Hydraulic Pump Division
36 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION SERIES SIZE L7 L8 L9 -A- CONTROL MTG. POSITION
6, 7 & 8 5.15
CONTROL IINDICATOR PORT PORT CONTROL PUMP IINDICATOR PORT PORT
FIG. PUMP (SAE 127-2) (130,9) FIG.
OPTION 9.43 5.63 OPTION ROT.
ROT. ROTATION "A" "B" ROTATION "A" "B"
6, 7 & 8 6.49 (239,6) (143,1)
1 CW CCW INLET OUTLET (SAE 152-4) (164,8) 2 CW CW INLET OUTLET

1 CCW CW INLET OUTLET 6.38 10.00 6.20 2 CCW CCW INLET OUTLET
"7D*" 11 & 14 (162,0) (254,1) (157,5) "7D*"
1 CW OUTLET INLET 2 CW CCW OUTLET INLET
CW
8.14 11.87 8.07
1 CCW OUTLET INLET 24 & 30 2 CCW CW OUTLET INLET
CCW (206,7) (301,5) (205,0)

P T SERVOVALVE INLET SERVOVALVE INLET


A- A+ SAE-8 STR. THD. SAE-8 STR. THD.
B+ B-
2 1
"B" OVERRIDE "A" OVERRIDE
L7 L7
TUBE B A TUBE

SERVOVALVE DIAGRAM
L9 L8
O
SERVOVALVE
F F

PORT PORT
PUMP CAM COIL
ROT.
SERVOVALVE
POLARITY PORTING "A" "B"
PORT PORT
PUMP
CW CAMA+ or B-
ABOVE
COIL
P---2 OUTLET INLET"A"
ROT. POLARITY PORTING "B" MATING CONN. F O F

#721-30004
CW BELOW A- or B+ P---1 INLET OUTLET
CW ABOVE A+ or B- P---2 OUTLET INLET -
CCW BELOW A+ or B- P---2 OUTLET INLET D D
CW ABOVE
BELOW A- or P---1
B+ P---1 INLET OUTLET 5MA/DC/NOM.
CCW A- or B+ INLET OUTLET
FIGURE -1
+
C C
FIGURE -2
CCW BELOW A+ or B- P---2 OUTLET INLET
-
B B
5MA/DC/NOM.
CCW ABOVE A- or B+ P---1 INLET OUTLET +
A A

SERVOVALVE DIAGRAM

-B- CONTROL MTG. POSITION SERIES SIZE L7 L8 L9 L10 -A- CONTROL MTG. POSITION
6, 7 & 8 5.15
VOL. INDICATOR PORT PORT (SAE 127-2) (130,9) VOL. INDICATOR PORT PORT
CONTROL
FIG. PUMP VALVE COMMAND 12.70 5.63 CONTROL
FIG. PUMP VALVE COMMAND
OPTION ROT. SHAFT ROT. (322,6) (143,1) OPTION ROT. SHAFT ROT.
D TO E "A" "B" 6, 7 & 8 6.49 D TO E "A" "B"
(SHOWN) (SAE 152-4) (164,8)
(SHOWN)
7.66
1 CW 0...-10V CCW INLET OUTLET (194,6) 2 CW 0...-10V CW INLET OUTLET
6.38 14.37 6.20
11 & 14 (162,0) (365,0) (157,5)
1 CCW 0...-10V CW INLET OUTLET 2 CCW 0...-10V CCW INLET OUTLET
"7J*" INLET
8.14 14.58 8.07 "7J*" INLET
1 CW 0...+10V CW OUTLET 24 & 30 (206,7) (370,3) (205,0) 2 CW 0...+10V CCW OUTLET

1 CCW 0...+10V CCW OUTLET INLET 2 CCW 0...+10V CW OUTLET INLET

CIRCULAR CONNECTOR-7 PIN, DIN 43563 L10


6 + PE
Zero position
Command A
0...±10V E F B
0...±20mA PID G
4...20mA D E C
D

Diagnostic F
spool stroke 0 U
0...±10V C
=
=
L7 L7
+ 0
G A B
Supply L9 L8
O
PE voltage
F F

22...30V

D1FP ( DF Plus) WIRING SCHEMATIC


F O F

FIGURE -1 FIGURE -2

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 37
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION SERIES SIZE L7 L8 L9 -A- CONTROL MTG. POSITION
6, 7 & 8 5.15
ROTARY SERVO (SAE 127-2) (130,9)
ROTARY SERVO PORT PORT
CONTROL PUMP PORT PORT 9.43 5.63 CONTROL PUMP
FIG. INPUT SHAFT OPTION FIG. INPUT SHAFT
OPTION ROT. "A" "B" 6, 7 & 8 6.49 (239,6) (143,1) ROT. "A" "B"
ROTATION ROTATION
(SAE 152-4) (164,8)
1 CW CCW INLET OUTLET 2 CW CW INLET OUTLET
6.38 10.00 6.20
11 & 14 (162,0) (254,1) (157,5)
1 CCW CW INLET OUTLET 2 CCW CCW INLET OUTLET
"7F*" 8.14 11.87 8.07
"7F*"
1 CW OUTLET INLET 24 & 30 2 CW CCW OUTLET INLET
CW (206,7) (301,5) (205,0)

CCW OUTLET INLET 2 CCW CW OUTLET INLET


1 CCW

MANUAL SERVOVALVE SHUT-OFF


SHOWN IN OPEN POSITION

P T SERVOVALVE INLET
A- A+ SAE-8 STR. THD.
B+ B- SEE ROTARY SERVO
2 1 SHAFT DETAIL TRIMMER ADJ. SEE ROTARY SERVO
SHAFT DETAIL
"B" OVERRIDE "A" OVERRIDE
L7 L7
TUBE B A TUBE

SERVOVALVE DIAGRAM
L9 L8
F O

SERVOVALVE
F

PORT PORT
PUMP SERVOVALVE
CAM COIL
PORT "A" PORT
PUMP ROT. COIL POLARITY PORTING "B"
CAM
ROT. CW ABOVE A+PORTING
POLARITY or B- P---2 "A"OUTLET "B"
INLET F F
O

CW BELOW A- or B+ P---1 INLET OUTLET


CW ABOVE A+ or B- P---2 OUTLET INLET
CCW BELOW A+ or B- P---2 OUTLET INLET 1.40 MAX. VOLUME STOP SERVOVALVE INLET 1.40
CW BELOW A- orABOVE
CCW
B+ A- P---1
or B+ P---1INLET
OUTLET (35,6) TRIMMER ADJ.
SAE-8 STR. THD.
MAX. VOLUME STOP (35,6)
INLET OUTLET
MAX. VOLUME STOP .45
CCW BELOW A+ or B- P---2 OUTLET INLET 1/4-20UNC TAP x
.25
DEEP .32
(11,4)

FIGURE -1 (6,4) (8,1)

CCW ABOVE A- or B+ P---1 INLET OUTLET FIGURE -2

ROYTARY SERVO SHAFT DETAIL


SERIES SIZE L7 L8 L9 .513
B
.508 A
6, 7 & 8 5.15 MAJOR DIA. KNURL
(SAE 127-2) (130,9) 13.03
10.63 5.63 (12.90 ) (32 TEETH PER INCH)
A B
& (270 1) (143 1)

-B- CONTROL MTG. POSITION SERIES SIZE L7 L8 L9 L10 -A- CONTROL MTG. POSITION
6, 7 & 8 5.15
CONTROL INPUT PORT PORT (SAE 127-2) (130,9) CONTROL INPUT PORT PORT
CONTROL
FIG. PUMP VALVE COMMAND 12.70 5.63 CONTROL
FIG. PUMP VALVE COMMAND
OPTION ROT. SHAFT ROT. (322,6) (143,1) OPTION ROT. SHAFT ROT.
D TO E "A" "B" 6, 7 & 8 6.49 D TO E "A" "B"
(SHOWN) (SAE 152-4) (164,8)
(SHOWN)
7.66
1 CW 0...-10V CCW INLET OUTLET (194,6) 2 CW 0...-10V CW INLET OUTLET
6.38 14.37 6.20
11 & 14 (162,0) (365,0) (157,5)
1 CCW 0...-10V CW INLET OUTLET 2 CCW 0...-10V CCW INLET OUTLET
"7K*" INLET
8.14 14.58 8.07 "7K*" INLET
1 CW 0...+10V CW OUTLET 24 & 30 (206,7) (370,3) (205,0) 2 CW 0...+10V CCW OUTLET

1 CCW 0...+10V CCW OUTLET INLET 2 CCW 0...+10V CW OUTLET INLET

MANUAL SERVOVALVE SHUT-OFF


CIRCULAR CONNECTOR-7 PIN, DIN 43563 SHOWN IN OPEN POSITION L10
6 + PE
Zero position
Command A
0...±10V E F B
0...±20mA n PID G
4...20mA D E C
PID D SEE ROTARY SERVO
SHAFT DETAIL
Diagnostic F
spool stroke 0 U
0...±10V C TRIMMER ADJ.
U
=
= = L7 L7
=
+ 0 + 0
G G A B A B
Supply
PE voltage Supply L9 L8
PE 22...30V voltage F O
F

22...30V
WIRING SCHEMATIC
D1FP ( DF Plus) WIRING SCHEMATIC
F O F

MAX. VOLUME STOP


TRIMMER ADJ. MAX. VOLUME STOP
MAX. VOLUME STOP
FIGURE -1 FIGURE -2
Parker Hannifin Corporation
Hydraulic Pump Division
38 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME
PRESSURE SIGNAL ROTARY SERVO PORT PORT PRESSURE SIGNAL ROTARY SERVO PORT PORT
CONTROL PUMP CONTROL PUMP
OPTION FIG. TO SAE-4 INPUT SHAFT OPTION FIG. TO SAE-4 INPUT SHAFT
ROT. "A" "B" ROT. "A" "B"
STR. THD. PORT: ROTATION STR. THD. PORT: ROTATION
1 CW "P1" CCW INLET OUTLET 2 CW "P2" CW INLET OUTLET

1 CCW "P2" CW INLET OUTLET 2 CCW "P1" CCW INLET OUTLET


"8A*" "8A*"
1 CW "P2" CW OUTLET INLET 2 CW "P1" CCW OUTLET INLET

1 CCW "P1" CCW OUTLET INLET 2 CCW "P2" CW OUTLET INLET

SEE ROTARY SERVO SEE ROTARY SERVO


SHAFT DETAIL SHAFT DETAIL
TRIMMER ADJ. LOCKNUT
.54 .54
(13,7) L7 L7 (13,7)
SEE TABLES 1-18 SEE TABLES 1-18

"P2" "P1"
2.47
F O F

(62,7)

2.47
(62,7) F
O F
"P1" "P2"

1.49 MAX. VOLUME STOP 1.49


1.00 1.00
(37,9) TRIMMER ADJ. (37,9)
1.00 (25,4) (25,4) 1.00
(25,4) (25,4) MAX. VOLUME STOP
MAX. VOLUME STOP
.45
(11,4)
.25 .32
1/4-20UNC TAP x DEEP

FIGURE -1
(6,4) (8,1) FIGURE -2
ROTARY SERVO SHAFT DETAIL
"Z" BRAKE ACTUATOR PORT .513
37 1/2˚ FLARED FITTING .508
MAJOR DIA. KNURL L7
SEE ROTARY SERVO 13.03 SEE ROTARY SERVO
SHAFT DETAIL
9/16-18 UNF ( 12.90 ) (32 TEETH PER INCH)
1.00
SEE TABLES 1-18
SHAFT DETAIL
TRIMMER ADJ. LOCKNUT
.59 (25,4)
.54 L7 .54
SEE TABLES 1-18 (15,1) 1.00
(13,7) (25,4) (13,7)

4.39 6.20
"P2"
(111,4) F O F (157,4) "P1"
2.47
(62,7)

2.47
(62,7) F
O F
4.39
(111,4)

1.49 MAX. VOLUME STOP 1.49


1.00 .59
(37,9) TRIMMER ADJ. (37,9)
1.00 (25,4) (15,1)
(25,4) MAX. VOLUME STOP
MAX. VOLUME STOP "Z" BRAKE ACTUATOR PORT
37 1/2˚ FLARED FITTING
FIGURE -1 9/16-18 UNF FIGURE -2
-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION
CONTROL SPRING OFF-SET TO MIN, VOLUME CONTROL SPRING OFF-SET TO MIN, VOLUME
PRESSURE SIGNAL ROTARY SERVO PORT PORT PRESSURE SIGNAL ROTARY SERVO PORT PORT
CONTROL PUMP CONTROL PUMP
OPTION FIG. TO SAE-4 INPUT SHAFT OPTION FIG. TO SAE-4 INPUT SHAFT
ROT. "A" "B" ROT. "A" "B"
STR. THD. PORT: ROTATION STR. THD. PORT: ROTATION
1 CW "P1" CCW INLET OUTLET 2 CW "P2" CW INLET OUTLET

1 CCW "P2" CW INLET OUTLET 2 CCW "P1" CCW INLET OUTLET


"8C*" "8C*"
1 CW "P2" CW OUTLET INLET 2 CW "P1" CCW OUTLET INLET

1 CCW "P1" CCW OUTLET INLET 2 CCW "P2" CW OUTLET INLET

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 39
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


MANUAL PORT PORT MANUAL PORT PORT
CONTROL PUMP ENERGIZE CONTROL PUMP ENERGIZE
OPTION FIG. OVERRIDE SHAFT OPTION FIG. OVERRIDE SHAFT
ROT. SOLENOID "A" "B" ROT. SOLENOID "A" "B"
ROTATION ROTATION
1 CW "A" CCW INLET OUTLET 2 CW "B" CW INLET OUTLET

1 CCW "B" CW INLET OUTLET 2 CCW "A" CCW INLET OUTLET


"9A*" "9A*"
1 CW "B" CW OUTLET INLET 2 CW "A" CCW OUTLET INLET

1 CCW "A" CCW OUTLET INLET 2 CCW "B" CW OUTLET INLET

L7 SEE MANUAL OVERRIDE


SEE MANUAL OVERRIDE SEE TABLES 1-18 SHAFT DETAIL
SHAFT DETAIL TRIMMER ADJ. LOCKNUT SOL. "B"
SOL. "A" 3.17
(80,5)
L7
2.67 SEE TABLES 1-18
(67,8)
5.12
O (130,1)

O
5.12
(130,1)
2.67
MAX. VOLUME STOP
(67,8)
3.17 SOL. "B" TRIMMER ADJ.
(80,5) SOL. "A" .55
MAX. VOLUME STOP
(14,0)
MAX. VOLUME STOP .19
HEX RECESS x .12 DEEP
(4,8)
FIGURE -1
(3,0)
FIGURE -2
MANUAL OVERRIDE
SHAFT DETAIL
"Z" BRAKE ACTUATOR PORT
37 1/2˚ FLARED FITTING
L7
2.67 9/16-18 UNF SEE TABLES 1-18
SOL. "B" 3.17
(67,8) TRIMMER ADJ. LOCKNUT
.59 SOL. "A" (80,5)
.54 L7 .54
SEE TABLES 1-18 (15,1)
(13,7) (13,7)

6.20 5.12
4.39 (130,1)
(111,4)
O
(157,4)

5.12
O
4.39
(130,1) (111,4)

MAX. VOLUME STOP


.59 2.67
3.17 SOL. "B" TRIMMER ADJ.
(15,1) (67,8)
(80,5) SOL. "A"
"Z" BRAKE ACTUATOR PORT MAX. VOLUME STOP
SEE MANUAL OVERRIDE MAX. VOLUME STOP 37 1/2˚ FLARED FITTING
SHAFT DETAIL SEE MANUAL OVERRIDE
FIGURE -1 9/16-18 UNF FIGURE -2 SHAFT DETAIL

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


MANUAL PORT PORT MANUAL PORT PORT
CONTROL PUMP ENERGIZE CONTROL PUMP ENERGIZE
OPTION FIG. OVERRIDE SHAFT OPTION FIG. OVERRIDE SHAFT
ROT. SOLENOID "A" "B" ROT. SOLENOID "A" "B"
ROTATION ROTATION
1 CW "A" CCW INLET OUTLET 2 CW "B" CW INLET OUTLET

1 CCW "B" CW INLET OUTLET 2 CCW "A" CCW INLET OUTLET


"9C*" "9C*"
1 CW "B" CW OUTLET INLET 2 CW "A" CCW OUTLET INLET

1 CCW "A" CCW OUTLET INLET 2 CCW "B" CW OUTLET INLET

Parker Hannifin Corporation


Hydraulic Pump Division
40 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Motor Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


CONTROL SPRING OFF-SET TO FULL VOLUME CONTROL SPRING OFF-SET TO FULL VOLUME
PRESSURE SIGNAL TO: PRESSURE SIGNAL TO:
CONTROL MOTOR PORT CONTROL MOTOR PORT
OPTION FIG. ROT. 1/8-27 N.P.T.F. 1/8-27 N.P.T.F. OPTION FIG. ROT. 1/8-27 N.P.T.F. 1/8-27 N.P.T.F.
"A" "A"
PORT "X" PORT "Y" PORT "X" PORT "Y"
1 CW INLET 2 CW INLET
"2A*" REDUCED SPEED FULL SPEED "2A*" FULL SPEED REDUCED SPEED
1 CCW OUTLET 2 CCW OUTLET
.513
SEE ROTARY SERVO .508 SEE ROTARY SERVO
MAJOR DIA. KNURL
SHAFT DETAIL 13.03 SHAFT DETAIL
( 12.90 ) (32 TEETH PER INCH)

.45 .45
(11,5) L7 L7 (11,5)
SEE TABLES 1-18 SEE TABLES 1-18

"Y" "X"
F O F 2.50
(63,5)

2.50
(63,5) F
O F

"X" "Y"

1.40 1.40
1.00 MAX. VOLUME STOP 1.00
(35,6) (35,6)
1.00 (25,4) (25,4) 1.00
MIN. VOLUME STOP (25,4) MIN. VOLUME STOP (25,4)
MAX. VOLUME STOP

(25,4) (25,4) MAX. VOLUME STOP


MIN. VOLUME STOP
FIGURE -1 -1 .45 FIGURE -2 ADJ.
FIGURE 1/4-20UNC TAP x
.25
DEEP .32
(11,4)
TRIMMER
(6,4) (8,1) FIGURE -2
ROTARY SERVO SHAFT DETAIL

.513
SEE ROTARY SERVO .508 SEE ROTARY SERVO
MAJOR DIA. KNURL
SEE ROTARY
SHAFT DETAIL SERVO 13.03 SHAFT DETAIL
SHAFT DETAIL ( 12.90 ) (32 TEETH PER INCH)

.45 SEE ROTARY SERVO .45


SHAFT DETAIL
NULL ADJ. 4.10 TRIMMER ADJ. MAX. VOLUME STOP
SCREW (104,0) L7
SEE TABLES 1-18 MAX. VOLUME STOP L7 4.30
SEE TABLES 1-18 (109,3)
MARYSVILLE , OHIO U.S.A.

ASS'Y NO.

5.02
SERIAL NO.

ELEC. RATINGS: L = 1.5 mh MAX.


I = 330 ma MAX. V = 10.56 VOLTS D.C. MAX.
HAZARDOUS LOCATION SUITABILITY:
1. NONINCENDIVE CLASS I, DIVISION 2,
GROUPS A, B, C, AND D.

(127,6)
2. CLASS II, DIVISION 2, GROUPS F AND G.
WARNING- DO NOT DISCONNECT
WHILE CIRCUIT IS LIVE UNLESS
LOCATION IS KNOWN TO BE
NONHAZARDOUS.
033-91428-B

033-91428-B

NONHAZARDOUS.

5.02
LOCATION IS KNOWN TO BE
WHILE CIRCUIT IS LIVE UNLESS
WARNING- DO NOT DISCONNECT
2. CLASS II, DIVISION 2, GROUPS F AND G.
GROUPS A, B, C, AND D.
1. NONINCENDIVE CLASS I, DIVISION 2,
HAZARDOUS LOCATION SUITABILITY:

(127,6)
V = 10.56 VOLTS D.C. MAX. I = 330 ma MAX.
L = 1.5 mh MAX. ELEC. RATINGS:

SERIAL NO.

ASS'Y NO.

MARYSVILLE , OHIO U.S.A.

4.30
(109,3) TRIMMER ADJ. MIN. VOLUME STOP
4.10 NULL ADJ.
FIGURE -1 MIN. VOLUME STOP FIGURE -2 (104,0) SCREW

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


CONTROL SPRING OFF-SET TO FULL VOLUME CONTROL SPRING OFF-SET TO FULL VOLUME
ROTARY SERVO ROTARY SERVO PORT PORT ROTARY SERVO ROTARY SERVO PORT PORT
CONTROL MOTOR CONTROL MOTOR
OPTION FIG. ROT. INPUT SHAFT INPUT SHAFT OPTION FIG. ROT. INPUT SHAFT INPUT SHAFT
CCW ROTATION CW ROTATION "A" "B" CCW ROTATION CW ROTATION "A" "B"

1 CW INLET OUTLET 2 CW INLET OUTLET


"5A*" CCW
REDUCED SPEED FULL SPEED "5A*" CCW
FULL SPEED REDUCED SPEED
1 OUTLET INLET 2 OUTLET INLET

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 41
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Motor Primary Controls GOLD CUP® Series - Open & Closed Circuits

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


CONTROL SPRING OFF-SET TO FULL VOLUME CONTROL SPRING OFF-SET TO FULL VOLUME
PRESSURE SIGNAL PRESSURE SIGNAL
MOTOR TO SAE-4 ROTARY SERVO MOTOR TO SAE-4 ROTARY SERVO
CONTROL PORT PORT CONTROL PORT PORT
FIG. ROT. STR. THD. PORT INPUT SHAFT FIG. ROT. STR. THD. PORT INPUT SHAFT
OPTION "A" "B" OPTION "A" "B"
ROTATION ROTATION
P2 P1

1 CW CW INLET OUTLET 2 CW CCW INLET OUTLET


"8A*" FULL SPEED "8A*" FULL SPEED
1 CCW CW OUTLET INLET 2 CCW CCW OUTLET INLET

SEE ROTARY SERVO SEE ROTARY SERVO


SHAFT DETAIL SHAFT DETAIL
TRIMMER ADJ. LOCKNUT
.54 .54
(13,7) L7 TRIMMER ADJ. LOCKNUT L7 (13,7)
SEE TABLES 1-18 SEE TABLES 1-18

"P2" "P1"
2.47
F O F

(62,7)

2.47
(62,7) F
O F
"P1" "P2"

MIN. VOLUME STOP

1.49 MAX. VOLUME STOP 1.49


1.00 1.00
(37,9) TRIMMER ADJ. (37,9)
1.00 (25,4) (25,4) 1.00
(25,4) .56 (25,4) MAX. VOLUME STOP
MIN. VOLUME STOP (14,2)
.45
FIGURE -1 1/4-20UNC TAP x
.25
DEEP .32
.3760
(11,4) .49
TRIMMER ADJ.

19˚ NULLED AT 0 CURRENT


(6,4)
.3755(8,1)
DIA.
(12,5)
FIGURE -2
(MECH. A B (9,550)
STOP) + (9,538)
CURRENT AT FULL DISPL.
350 MA. NOM. .31
COIL RESISTANCE DIA. WITH
(7,9)
25 NOM. .20 WIDE FLAT
6˚ CW O WITH ELECTRICAL POLARITY AS SHOWN
(MECH. INPUT SHAFT WILL ROTATE CW
STOP)
.15
A O A+ ELECTRICAL INPUT (3,8)
POLARITY .390
(ELECT. RECEPTACLE CONN. 5/8-24UNEF x MAX.
MATING CONN. HALF, MS3106E-10SL-4S)
(9,91) MANUAL OVERRIDE DETAIL
SERVO MUST BE DISCONNECTED

-B- CONTROL MTG. POSITION -A- CONTROL MTG. POSITION


CONTROL SPRING OFF-SET TO FULL VOLUME CONTROL SPRING OFF-SET TO FULL VOLUME
MANUAL PORT PORT MANUAL PORT PORT
CONTROL MOTOR ENERGIZE CONTROL MOTOR ENERGIZE
OPTION FIG. OVERRIDE SHAFT OPTION FIG. OVERRIDE SHAFT
ROT. SOLENOID "A" "B" ROT. SOLENOID "A" "B"
ROTATION ROTATION
1 CW CW INLET OUTLET 2 CW CCW INLET OUTLET
"9A*" FULL SPEED "9A*" FULL SPEED
1 CCW CW OUTLET INLET 2 CCW CCW OUTLET INLET

.55 L7 SEE MANUAL OVERRIDE


SEE MANUAL OVERRIDE (14,0) SEE TABLES 1-18 SHAFT DETAIL
SHAFT DETAIL .19
MAX. VOL. LOCKNUT HEX RECESS x 3.17
(4,8) .12 (80,5)
L7 DEEP
2.67 SEE TABLES 1-18
(3,0)
(67,8)
5.12
O (130,1)

MANUAL OVERRIDE
SHAFT DETAIL

O
5.12 MIN. VOLUME STOP
(130,1)
2.67
(67,8)
3.17 MAX. VOL. LOCKNUT
(80,5) MAX. VOLUME STOP MAX. VOLUME STOP
MIN. VOLUME STOP

FIGURE -1 FIGURE -2

Parker Hannifin Corporation


Hydraulic Pump Division
42 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Secondary Control GOLD CUP® Series - Open & Closed Circuits

-A- CONTROL MTG. POSITION SERIES SIZE L7 L10 L11 -B- CONTROL MTG. POSITION
6, 7 & 8 5.15
PORT PORT TORQUE (SAE 127-2) (130,9) 6.20 6.48 PORT PORT TORQUE
CONTROL PUMP INPUT SHAFT CONTROL PUMP INPUT SHAFT
OPTION FIG. ROT. ROTATION "A" "B"
LIMITER
6, 7 & 8 (157,4) (164,5) OPTION FIG. ROT. ROTATION
LIMITER
ADJ. 6.49 "A" "B" ADJ.
(SAE 152-4) (164,8)
3 CW CW INLET OUTLET E 4 CW CCW INLET OUTLET F
6.38 5.83 5.83
11 & 14 (162,0) (148,0) (148,0)
1 CCW CCW INLET OUTLET F 2 CCW CW INLET OUTLET E
"**4" 8.14 7.15 7.15 "**4"
1 CCW CW OUTLET INLET E 24 & 30 (206,7) (181,6) (181,6) 2 CCW CCW OUTLET INLET F
3 CW CCW OUTLET INLET F 4 CW CW OUTLET INLET E
"E" TORQUE LIMITER
"F" TORQUE LIMITER ADJUSTMENT SCREW
ADJUSTMENT SCREW
L7 L7

F O
F L10 L11

F F
O
4.97
(126,2)

1.40 "E" TORQUE LIMITER "F" TORQUE LIMITER 1.40


(35,5) FIGURE -1 ADJUSTMENT SCREW ADJUSTMENT SCREW FIGURE -2 (35,5)

"F" TORQUE LIMITER "E" TORQUE LIMITER


ADJUSTMENT SCREW ADJUSTMENT SCREW

L7 L7

F O
F L11 L10

F F
O
4.97
(126,2)

1.40
(35,5)
FIGURE -3 "E" TORQUE LIMITER "F" TORQUE LIMITER
ADJUSTMENT SCREW FIGURE -4
1.40
(35,5)
ADJUSTMENT SCREW

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 43
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump & Motor Secondary Controls GOLD CUP® Series - Open & Closed Circuits

-A- CONTROL MTG. POSITION -B- CONTROL MTG. POSITION


CONTROL PUMP INPUT SHAFT PORT PORT CONTROL PUMP INPUT SHAFT PORT PORT
OPTION FIG. OPTION FIG.
ROT. ROTATION "A" "B" ROT. ROTATION "A" "B"

2 CW CW INLET OUTLET 1 CW CCW INLET OUTLET


"**6" CCW INLET OUTLET
"**6" CCW INLET OUTLET
2 CCW 1 CW
or or
2 CW CCW OUTLET INLET 1 CW CW OUTLET INLET
"**8" "**8"
2 CCW CW OUTLET INLET 1 CCW CCW OUTLET INLET

L7 L7
SEE TABLES 1-18 SEE TABLES 1-18

F O
F
P /N
MARYSVILLE, OHIO 43040 USA
ELECTROHYDRAULIC SYSTEMS

ELECTROHYDRAULIC SYSTEMS
MARYSVILLE, OHIO 43040 USA

S/N
S/ N

P/N
F O F

3.76 3.76
"**6" "**6"
(95,5) MATING CONN. MATING CONN. (95,5)
#721-30059 #721-30059
4.15 RED 4.15
"**8"
(105,4) FIGURE -2 +15VDC
B B +15VDC
8
RED D D FIGURE -1 (105,4)
"**8"

BLUE
OUT C C OUT BL
C C
4 2
GREEN
COMMON F F GN
B B
7
C
-15VDC
BLACK WH
D D -15VDC F F

DC RVDT DIAGRAM POTENTIOMETER DIAGRAM


("**8" REF.) ("**6" REF.)

-A- CONTROL MTG. POSITION -B- CONTROL MTG. POSITION


CONTROL PUMP INPUT SHAFT PORT PORT CONTROL PUMP INPUT SHAFT PORT PORT
OPTION FIG. OPTION FIG.
ROT. ROTATION "A" "B" ROT. ROTATION "A" "B"

2 CW CW INLET OUTLET 1 CW CCW INLET OUTLET

2 CCW CCW INLET OUTLET 1 CCW CW INLET OUTLET


"**2" "**2"
2 CW CCW OUTLET INLET 1 CW CW OUTLET INLET

2 CCW CW OUTLET INLET 1 CCW CCW OUTLET INLET

L7 L7
SEE TABLES 1-18 SEE TABLES 1-18

F O
F

F O F

1.40 1.40
(35,5) FIGURE -2 FIGURE -1 (35,5)

Parker Hannifin Corporation


Hydraulic Pump Division
44 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Rear Adapters GOLD CUP® Series - Open & Closed Circuits

SAE
Mounting and Coupling
Blanking
Mounting 82-2 (A) 101-2 (B) 101-4 (B) 127-2 (C) 127-4 (C) 152-4 (D) 165-4 (E) 177-4 (F)
Plate
Coupling None 16-4 (A) 22-4 (B) 22-4 (B) 32-4 (C) 32-4 (C) 44-4 (D) 44-4 (E) 50-4 (F)

P6/7/8 S, X M A B - - - - - -

P6/7/8 R, L , M M A B - C - - - -
Pumps

P11/14 S, X M A B - - - - - -

P11/14 R, L, M M A B B C C D E

P24/30 S, X - - B - C - - - -

P24/30 R, L, M M - B B C C D E F

M6/7/8 R, L, M, N M A B - C - - - -
Motors

M11/14 R, L, M, N M A B B C C D E -

M24/30 R, L, M, N M - B B C C D E F

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 45
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
6,7,8 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

P6-14 S,X
SAE 82-2 (A) WITH COUPLING 16-4
SAE 101-2 (B) WITH COUPLING 22-4

Parker Hannifin Corporation


Hydraulic Pump Division
46 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
6,7,8 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

2.40 MIN.
SAE-"A" INTERNAL SPLINE DATA (61,0)
M6,7 R,L,M,N FLAT ROOT SIDE FIT J498B .14 SAE-"B" INTE
.29
P6,7,8 R,L,M 9 TEETH (3,6) X 45˚ FLAT ROOT
SAE 127-2 (C) WITH COUPLING 32-4 16-32 PITCH (7,4) 13 TEETH
30˚ PRESSURE ANGLE 16-32 PITCH
SAE 101-2 (B) WITH COUPLING 22-4 .6360-.6250 30˚ PRESSU
SAE 82-2 (A) WITH COUPLING 16-4 MAJOR DIA. .8860-.8750
(16,154-15,875 )
.5139-.5089 (22,504-22,225
MINOR DIA. .7583-.7533
(13,053-12,926)
(19,261-19,134)
2.09
(53,1)
2.40 MIN. 3.251
(61,0) .08 3.253
X 45˚ DIA.
(2,0) 82,58
.40
SAE-"B" INTERNAL SPLINE DATA 82,63 4.19
(10,2) SAE-C INT
FLAT ROOT SIDE FIT J498B (106,4)
13 TEETH FLAT ROOT
16-32 PITCH 14 TEETH
30˚ PRESSURE ANGLE SAEPITC
12-24 "A"
.8860-.8750
MAJOR DIA. 30˚ PRESS
(22,504-22,225 ) 2.88 AUX. MTG.
1.2500-1.26 3/8 -16 UNC-2B TAP x
.75
DP.
.7583-.7533 .39 (19,0)
MINOR DIA. (73,0) (31.750-32.0 2 PLACES AS SHOWN
(19,261-19,134) (9,9)
1.0862-1.09 MIN.
4.002 (27.589-27.7 1.38
4.006 SPLINE LENGTH
DIA. (34,9)
101,65 5.75
101,75
(146,0)
SAE 82-2 (A)
SAE "B" 1.00
1/2 -13 UNC-2B TAP x DP.
AUX. MTG. .39
2 PLACES AS SHOWN
(25.4)
.75 (9,9)
Px DP. MIN.
(19,0)
N 1.38
SPLINE LENGTH
(34,9)

2.24
MIN.
SAE 101-2 (B) (56,9) .53
(13.5) .08
x45˚
(2.0)
SAE-C INTERNAL SPLINE DATA
FLAT ROOT SIDE FIT (J498B)
14 TEETH
12-24 PITCH
3.56
30˚ PRESSURE ANGLE
1.2500-1.2630 (90,4)
MAJOR DIAMETER
(31.750-32.080)
1.0862-1.0912
MINOR DIAMETER
(27.589-27.716)
5.002
5.006
DIA.
127.05
127.15
7.12
(180,8)
1.00 SAE "C"
Px DP.
WN
(25.4) AUX. MTG.
.74
MIN.
(18,8)
1.32
SPLINE LENGTH
(33,5) 1.00
5/8 -11 UNC-2B TAP x DP.
(25.4)
2 PLACES AS SHOWN

SAE 127-2 (C)

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 47
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
11,14 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M11,14 R,L,M,N
P11,14 R,L
BLANKING PLATE

M11,14 R,L,M,N
P11,14 R,L,M
SAE 82-2 (A) WITH COUPLING 16-4

Parker Hannifin Corporation


Hydraulic Pump Division
48 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
11,14 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M11,14 R,L,M,N
P11,14 R,L,M
SAE 101-2 (B) WITH COUPLING 22-4
SAE 101-4 (B) WITH COUPLING 22-4

M11,14 R,L,M,N
P11,14 R,L,M
SAE 127-2 (C) WITH COUPLING 32-4
SAE 127-4 (C) WITH COUPLING 32-4

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 49
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
11,14 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M11,14 R,L,M,N
P11,14 R,L,M
SAE 152-4 (D) WITH COUPLING 44-4

M11,14 R,L,M,N
P11,14 R,L,M
SAE 165-4 (E) WITH COUPLING 44-4

3.50 3.50
(88.9) (88.9)
1.06
(26.9)

Parker Hannifin Corporation


Hydraulic Pump Division
50 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
P24, 30 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

P24,30,S,X
SAE 101-2 (B) WITH COUPLING 22-4

1.82
46,2

3.26
82,8

3.26
82,8

1.82
46,2

P24,30,S,X
SAE 127-2 (C) WITH COUPLING 32-4
SAE 127-4 (C) WITH COUPLING 32-4

1.82
46,2

3.26
82,8

3.26
82,8

1.82
46,2

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 51
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
24, 30 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M24,30 R,L,M,N
P24,30 R,L,M
BLANKING PLATE

7/8"-9 UNC X
1.25 (31,8) DP.
OVERHUNG SUPPORT
FITTING

.67
(17.1)

M24,30 R,L,M,N
P24,30 R,L,M
SAE 101-2 (B) WITH COUPLING 22-4
SAE 101-4 (B) WITH COUPLING 22-4
5.750 SAE 22-4 ("B")
(146,05 ) SAE 22-4 INTERNAL INVOLUTE SPLINE DATA
2.875 PER J498b 1969
( 73,02 ) FLAT ROOT SIDE FIT CLASS-1
2 BOLT MOUNT
16/32 PITCH
1/2 -13 UNC X 1.00 DP.
30˚ PRESSURE ANGLE
(25,4) 13 TEETH
.44 AS SHOWN
.7583-.7533 (19,261-19,134) MINOR DIA.
(11,2)

30 ˚

4.004
4.002
DIA.
101,69
( 101,67 )
4.21 DIA
(107,0)

7/8"-9 UNC X SEALING "O" RING


1.25 (31,8) DP. ARP - 155
OVERHUNG SUPPORT
FITTING 45˚

4 BOLT MOUNT
.67 1/2 -13 UNC X 1.00 DP.
.52
13,2 (25,4)
2.52
( 17,0 ) ON 5.000 BOLT CIRCLE
MIN. (127,00)
(64,0)
SAE 101-2 ("B" 2 BOLT) EQUALLY SPACED
SAE 101-4 ("B" 4 BOLT)

Parker Hannifin Corporation


Hydraulic Pump Division
52 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
24, 30 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M24,30 R,L,M,N
P24,30 R,L,M
SAE 127-2 (C) WITH COUPLING 32-4
SAE 127-4 (C) WITH COUPLING 32-4
1.31
(33,3) 45˚

.53 2 BOLT MOUNT


(13,5 ) 5/8 -11 UNC X 1.25 DP.
(31,8)
ON 7.125 BOLT CIRCLE
(180,98)
90˚
AS SHOWN

30˚

5.004
5.002 DIA.
127.09
( 127.07 )
5.21 DIA 4 BOLT MOUNT
(132,4) 1/2 -13 UNC X 1.00 DP.
(25,4)
ON 6.375 BOLT CIRCLE
(161,93)
7/8"-9 UNC X EQUALLY SPACED
SEALING "O" RING
1.25 (31,8) DP.
ARP - 159
OVERHUNG SUPPORT
FITTING

.54
.71 SAE 127-2 ("C" 2 BOLT) SAE 32-4 ("C")
13,7 SAE 32-4 INTERNAL INVOLUTE SPLINE DATA
3.82 ( )
( 97,0 )
18,0
SAE 127-4 ("C" 4 BOLT) PER J498b 1969
FLAT ROOT SIDE FIT CLASS-1
12/24 PITCH
30˚ PRESSURE ANGLE
1.0912-1.0862 (27,716-27,589) MINOR DIA.

M24,30 R,L,M,N
P24,30 R,L,M
SAE 152-4 (D) WITH COUPLING 44-4

1.31
(33,3)

.50
(12,7 )

30˚

8 BOLT MOUNT
3/4 -10 UNC THRU (1.31 DEEP REF.)
6.004
ON 9.000 BOLT CIRCLE
6.002
DIA. (228,60)
152.46
( 152.44 ) 8 PLACES - EQUALLY SPACED
AS SHOWN

6.21 DIA
(157,8)

SAE 44-4 ("D" & "E")


7/8"-9 UNC X SAE 44-4 INTERNAL INVOLUTE SPLINE DATA
1.25 (31,8) DP. PER J498b 1969
SEALING "O" RING
OVERHUNG SUPPORT FLAT ROOT SIDE FIT CLASS-1
ARP - 163 8/16 PITCH
FITTING
30˚ PRESSURE ANGLE
13 TEETH
1.5110-1.5060 (38,379-38,252) MINOR DIA.

.54
.71

3.82 ( 13,7
18,0 )
SAE 152-4 ("D" 4 BOLT)
( 97,0 )

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 53
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
24, 30 Rear Adapters GOLD CUP® Series - Open & Closed Circuits

M24,30 R,L,M,N
P24,30 R,L,M
1.31
SAE 165-4 (E) WITH COUPLING 44-4 (33,3)
.64 4 BOLT MOUNT 16.52 DIA
(16,3 ) 3/4-10 UNC THRU (419,6)
ON 12.500 BOLT CIRCLE
(317,50)
4 PLACES - EQUALLY SPACED

30˚

6.504
6.502 DIA.
165.14
( 165.12 )
6.71 DIA
(170,6)

7/8"-9 UNC X
1.25 (31,8) DP. SEALING "O" RING
OVERHUNG SUPPORT ARP - 165
FITTING

SAE 44-4 ("D" & "E")


SAE 44-4 INTERNAL INVOLUTE SPLINE DATA
.54
.71 PER J498b 1969
FLAT ROOT SIDE FIT CLASS-1
3.82 ( 13,7
18,0 )
SAE 165-4 ("E" 4 BOLT) 8/16 PITCH
( 97,0 ) 30˚ PRESSURE ANGLE
13 TEETH
1.5110-1.5060 (38,379-38,252) MINOR DIA.

M24,30 R,L,M,N
P24,30 R,L,M
1.31
SAE 177-4 (F) WITH COUPLING 50-4 (33,3)
.64 16.52 DIA
(16,3) (419,6)

4 BOLT MOUNT
1" -8 UNC X 1.31 DP.
4-PLACES (33,3)

30˚

9.75 SQUARE
(247,6 )

7.001
7.003 DIA.
177,82
( 177,88 )

7.28 DIA 4.88


(184,9) (123,8 )

7/8"-9 UNC X
1.25 (31,8) DP.
OVERHUNG SUPPORT SEALING "O" RING
FITTING ARP - 167

SAE 50-4 ("F")


SAE 50-4 INTERNAL INVOLUTE SPLINE DATA
.54
.71 PER J498b 1969
FLAT ROOT SIDE FIT CLASS-1
3.82 ( 13,7
18,0 )
8/16 PITCH
( 97,0 ) SAE 177-4 ("F" 4 BOLT) 30˚ PRESSURE ANGLE
15 TEETH
1.7524-1.7574 (44,511-44,638) MINOR DIA.

Parker Hannifin Corporation


Hydraulic Pump Division
54 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Inlet Conditions GOLD CUP® Series - Open & Closed Circuits

INLET CONDITIONS AT SEA LEVEL INLET CONDITIONS AT SEA LEVEL


21.7 1.50 21.7 1.50

Absolute pressure, PSIA


Absolute pressure, PSIA

20.7 1.43 20.7 1.43

Absolute pressure, Bar


Absolute pressure, Bar
19.7 1.36 19.7 1.36
18.7 1.29 18.7 1.29
17.7 1.22 17.7 1.22
16.7 1.15 16.7 1.15
15.7 1.08 15.7 1.08
14.7 1.01 14.7 1.01
13.7 0.95 13.7 0.95
12.7 0.88 12.7 0.88
11.7 0.81 11.7 0.81
10.7 0.74 10.7 0.74
1200 1400 1600 1800 2000 2200 2400 1200 1400 1600 1800 2000 2200 2400
Speed, RPM Speed, RPM
P6V & P6F P7V & P7F

INLET CONDITIONS AT SEA LEVEL


21.7 1.50
Absolute pressure, PSIA

20.7 1.43
Absolute pressure, Bar

19.7 1.36
18.7 1.29
17.7 1.22
16.7 1.15
15.7 1.08
14.7 1.01
13.7 0.95
12.7 0.88
11.7 0.81
10.7 0.74
1200 1400 1600 1800 2000 2200 2400
Speed, RPM
P8V & P8F

INLET CONDITIONS AT SEA LEVEL INLET CONDITIONS AT SEA LEVEL


21.7 1.50 21.7 1.50
Absolute pressure, PSIA
Absolute pressure, PSIA

20.7 1.43 20.7 1.43

Absolute pressure, Bar


Absolute pressure, Bar

19.7 1.36 19.7 1.36


18.7 1.29 18.7 1.29
17.7 1.22 17.7 1.22
16.7 1.15 16.7 1.15
15.7 1.08 15.7 1.08
14.7 1.01 14.7 1.01
13.7 0.95 13.7 0.95
12.7 0.88 12.7 0.88
11.7 0.81 11.7 0.81
10.7 0.74 10.7 0.74
1200 1400 1600 1800 2000 2200 2400 1200 1400 1600 1800 2000 2200 2400
Speed, RPM Speed, RPM
P11V P14V

Note: The absolute inlet pressure is the pressure required to fill the pump with petroleum based fluids. The maximum pressure in the inlet port is 200
psi, 14 bar. For unboosted systems, the diameter of the suction line must be sized to allow a maximum velocity not higher than 4 ft/sec. A coarse
screen may be considered in the suction line, no filter. For water in oil invert emulsions and water glycols increase the inlet absolute pressure by 25%,
for phosphate ester increase the absolute inlet pressure by 35%. Any inlet pressures above atmospheric may increase noise levels and decrease effi-
ciencies noted in this literature. Please consult your nearest Parker Office for further details.

Inlet characteristics-auxiliary pump, port C


Series Speed Displacement Pressure absolute
rpm in3/rev cm3/rev psi bar
6, 7, 8, 11, 14 1200 1.07 17,5 9.5 0,66
6, 7, 8, 11, 14 1800 1.07 17,5 9.5 0,66
6, 7, 8, 11, 14 2400 1.07 17,5 10.5 0,72
24, 30 1200 4.84 79,3 9.5 0,66
24, 30 1800 4.84 79,3 10.5 0,72

Note: Maximum pressure on inlet port C is 200 psi, 14 bar.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 55
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

PRESSURE - PSI PRESSURE - BAR

Performance curves Series 6 Performance curves Series 6


Pump at full displacement Pump at full displacement

SPEED - RPM SPEED - RPM

Performance curves Series 6 Performance curves Series 6


Motor at full displacement Motor at full displacement

Parker Hannifin Corporation


Hydraulic Pump Division
56 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

PRESSURE - PSI PRESSURE - BAR

Performance curves Series 7 Performance curves Series 7


Pump at full displacement Pump at full displacement

SPEED - RPM SPEED - RPM

Performance curves Series 7 Performance curves Series 7


Motor at full displacement Motor at full displacement

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 57
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

PRESSURE - PSI PRESSURE - BAR

Performance curves Series 8 Performance curves Series 8


Pump at full displacement Pump at full displacement

Parker Hannifin Corporation


Hydraulic Pump Division
58 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

PRESSURE - PSI PRESSURE - BAR

Performance curves Series 11 Performance curves Series 11


Pump at full displacement Pump at full displacement

SPEED - RPM SPEED - RPM

Performance curves Series 11 Performance curves Series 11


Motor at full displacement Motor at full displacement

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 59
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

PRESSURE - PSI PRESSURE - BAR

Performance curves Series 14 Performance curves Series 14


Pump at full displacement Pump at full displacement

SPEED - RPM SPEED - RPM

Performance curves Series 14 Performance curves Series 14


Motor at full displacement Motor at full displacement

Parker Hannifin Corporation


Hydraulic Pump Division
60 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Performance Curves U.S./METRIC GOLD CUP® Series - Open & Closed Circuits

*PRESSURE-BAR
* PRESSURE - PSI * PRESSURE - BAR
Performance curves Series 24 Performance curves Series 24
Pump at full displacement Pump at full displacement

* PRESSURE - PSI * PRESSURE - BAR


Performance curves Series 30 Performance curves Series 30
Pump at full displacement Pump at full displacement

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 61
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

CODE DESCRIPTION HYDRAULIC CIRCUIT

TO VANE CHAMBERS

10 MANUAL SCREW ADJUST

SERVO

TO VANE CHAMBERS

2A TWO POSITION CONTROL

SERVO

TO VANE CHAMBERS

2H 3 POSITION CONTROL

SERVO

TO VANE CHAMBERS

2 POSITION CONTROL WITH


2M
CEPTOP3, NG6 VALVE
SERVO

Parker Hannifin Corporation


Hydraulic Pump Division
62 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

TYPICAL PERFORMANCE DESCRIPTION OF OPERATION


CAM ANGLE

o
19 Spring loaded toward maximum displacement, with an adjustment
screw to limit the displacement anywhere between 0% and 100%. A
minimum volume stop is also supplied so that when the rotary servo
19
o
shaft is turned, the displacement can be varied only between the
19
o
minimum and maximum settings.
SHAFT ROTATION
Torque required to rotate servo shaft:
o
20 lb-in, 2.56 Nm.
19

CAM ANGLE

o
Hydraulically piloted non-proportionally between adjustable minimum
19 and maximum displacements. The control is spring loaded toward
minimum when used on pumps, to maximum on motors. Servo pres-
sure is switched by an external valve to drive the control in either
o
direction. When used on motors, the minimum setting can be set no
19 lower than 30% of maximum.
MIN MAX
SERVO
SHAFT
ROTATION

CAM ANGLE

o
19

Hydraulically piloted non-proportionally between an adjustable


3 minimum displacement of 0±5% and two fully adjustable maximum
o
19 displacements, one in either direction, and spring loaded toward
o
2 19 minimum. Servo pressure is switched by an external valve to drive the
1
SHAFT control in either direction.
ROTATION
o
19

CAM ANGLE

Same as 2A except a CEPTOP3, NG6 two position directional valve


o
19 is mounted to the control. With the solenoid de-energized, the control
is spring loaded to zero for pumps and to maximum displacement for
motors. Energizing the solenoid drives the control toward maximum
o
displacement on pumps, minimum on motors. When used on motors,
19 the minimum settings can be no less than 30% of maximum.
SHAFT ROTATION

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 63
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

CODE DESCRIPTION HYDRAULIC CIRCUIT


TO VANE CHAMBERS

3 POSITION CONTROL
2N
WITH CEPTOP3, NG6 VALVE
SERVO

TO VANE CHAMBERS

SPRING CENTERED
40
ROTARY SERVO

SERVO

TO VANE CHAMBERS

SPRING CENTERED ROTARY


4A SERVO WITH ADJUSTABLE
STOPS

SERVO

TO VANE CHAMBERS

SERVO

SPRING CENTERED ROTARY


SERVO WITH AUTOMATIC
4B
BRAKE AND BYPASS
CONTROL

BRAKE REPLENISHING

Parker Hannifin Corporation


Hydraulic Pump Division
64 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

TYPICAL PERFORMANCE DESCRIPTION OF OPERATION


CAM ANGLE

19
o Same as 2H except a CEPTOP3, NG6 three position directional valve
is mounted to the control. With the solenoids de-energized, the control
is spring loaded to zero. Energizing a solenoid drives the control toward
3

19
o maximumdisplacement in one of the two directions.
o
2 19
1

SERVO SHAFT
ROTATION
o
19

CAM ANGLE
The 40 is the basic displacement control for all Goldcup. It is actuated by
STROKE RATE a servo shaft that is rotated from 0º - 19º, either side of center. This action
o
ZERO TO MAXIMUM 19 opens a unique slide valve to port servo oil to and from the vane cham-
P6,7,8 0.8 SEC
P11,14 1.5 SEC
bers that actuate the rocker cam. Vanes, integral to the cam, move the
P24, 30 1.8 SEC cam so that it follows the rotary servo input shaft motion exactly. When
o
19
o
the cam reaches the position equal to that of the input shaft, the slide
19
valve closes. Any cam motion due to pumping forces immediately opens
SHAFT ROTATION the slide valve to correct the cam position.
ANGLE

19
o
Springs cause the control to return to zero stroke when no external force
is applied to the servo shaft. An adjustment is provided to locate the exact
zero position, to prevent machine creep.

CAM ANGLE

19
o The 4A control is the same as the 40, with addition of adjustable maxi-
mum volume stop screws, with locking caps, to limit the control to less
than 100% displacement. Stops are present on both sides of center and
19
o may be set independently to different settings.
o
19

SERVO SHAFT
ROTATION ANGLE
o
19

The 4B control is the same as the 4A control, application of an on-stroke motion at the rotary servo shaft,
with the addition of an output port that will pro- and that cause the brake to remain released even after the
vide servo pressure to control a spring applied, rotary servo shaft is recentered, until the pump rocker cam
pressure released parking brake. The control actually returns to zero, at which time the brake will set. Ad-
contains anticoincidence functions that cause ditionally, a small bypass is opened between the pump A &
the brake to release immediately upon B ports to bypass any flow that is generated if the pump is
CAM ANGLE not exactly zeroed. The bypass closes whenever the brake
is released.
o
19 BRAKE PRESSURE HIGH
BYPASS CLOSED

o
19
o
19

SERVO SHAFT
ROTATION ANGLE
o o
o
19 o
19
19 ±2 BRAKE PRESSURE LOW
BYPASS OPEN

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 65
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

CODE DESCRIPTION HYDRAULIC CIRCUIT

TO VANE CHAMBERS

SPRING CENTERED BRAKE AND


4C ADJUSTABLE BYPASS CONTROL
(AUTOMATIC BRAKE CONTROL)

SERVO

TO VANE CHAMBERS

5A ELECTROHYDRAULIC CONTROL

SERVO

TO VANE CHAMBERS

8A HYDRAULIC STROKER P2 P1

SERVO

Parker Hannifin Corporation


Hydraulic Pump Division
66 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

TYPICAL PERFORMANCE DESCRIPTION OF OPERATION

CAM ANGLE

o
19

19
o This control combines the features of the 4A and 4B controls.See
19
o above descriptions.
SERVO SHAFT
ROTATION ANGLE
o
19

CAM ANGLE

o
19

The 5A control controls displacement in proportion to an electric cur-


rent between zero and 350 milliamps. The control is available with or
IMAX without a 10% deadband. Positive polarity drives the control in one
IMAX direction, and negative polarity in the other. Adjustable maximum
INPUT CURRENT
displacement stops are included. The 5C option, with automatic
DEADBAND
brake control, is also available.
o
19

CAM ANGLE

o
19

The 8A control controls displacement in proportion to a hydraulic


pressure, values listed below. Pressure applied in the P1 port drives
PIMAX
MAX the pump on stroke in one direction, P2 port in the other. Adjustable
PIMAX
MAX maximum displacement stops are included. The 8C option, with
automatic brake control, is also available.
o
19

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 67
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

CODE DESCRIPTION HYDRAULIC CIRCUIT

TO VANE CHAMBERS

9A ELECTRIC STROKER

SERVO

TO VANE CHAMBERS

COMMAND

7D6
7D8 HIGH IQ SERVOVALVE
SERVO
7F6 CONTROL FEEDBACK
7F8 (POTENTIOMETER
COMPENSATOR OR RVDT
PILOT
(V PORT)

Parker Hannifin Corporation


Hydraulic Pump Division
68 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Primary Displacement Control Options GOLD CUP® Series - Open & Closed Circuits

TYPICAL PERFORMANCE DESCRIPTION OF OPERATION

The 9A control controls displacement in proportion to an electric current


between zero and 350 milliamps for the 24 volt version, and up to 650 mil-
liamps for the 12 volt version. The control signal is a Pulse Width Modulated
signal. Current signal to one coil drives the pump in one direction, and to
the other coil in the opposite. Adjustable maximum displacement stops are
included. The 9C option, with automatic brake control, is also available.
CAM ANGLE Specifications:
Hysteresis 5% typical, 8% maximum
Linearity 8%
o
19 Response P6,7,8 0.9 seconds, zero to full stroke or back
P11,14 1.5 seconds, zero to full stroke or back
P24, 30 1.8 seconds, zero to full stroke or back
Repeatability 2%
IMAX Temperature null shift <2% per 100ºF (38º C)
IMAX Servo pressure required 200-1000 psi (14-70 bar), 400 nominal (28 bar)
Coil resistance 41 ohms (24v coil) & 10 ohms (12v coil)
INPUT
Electrical input* 270 ma minimum, 325 ma nominal, 350 ma maximum (24v coil)
CURRENT
o
Neutral deadband* 150 ma minimum, 180 ma nominal, 210 ma maximum (24v coil)
19
Manual override 3/16" Allen wrench, 30 in-lb (3.4Nm) with zero signal
Fluid types All

Available Jupiter 900 card S20-14078


open-loop drivers Dual Driver module 027-22071-0
Power supply 762-30026-0
Euro card holder EX00-S07
Electrical connector DIN 43650 type AF, 16-01008-8
Fluid cleanliness NAS 1638, class 8 or ISO 17/14

* 12V coils are twice these values

The 7** control is a high response displacement control that uses


a servovalve to direct high flow levels to and from the vane chambers, in
CAM ANGLE
order to achieve high stroke rates on the pump. A feedback potentiometer
or RVDT (Rotary Variable Differential Transformer) is used to feed back
the rocker cam position to the controlling electronics to achieve stable
o
19
operation.
The 7D6 control uses a servovalve and a feedback potentiometer for
feedback, the 7D8 uses an RVDT.
100%
100%
The 7F6 control uses servovalve and a the feedback potentiometer, but also
COMMAND
has a special valve block with a valve in it to shut off the servovalve, so that
control may be taken over by a 4A2 control also mounted to the pump as a
19
o manual override. The 7F8 is the same, except using an RVDT.
Specifications for 7D,7F:
Specifications for P6,7,8 P11,14 P24/30
Hysteresis <±1% <±1% ±1%
Linearity <±0.5% <±0.5% ±0.5%
Step Response 180ms 300 Ms 360 Ms
Small Signal Frequency Response 10 Hz, 400 psi (28 bar) 8.2 Hz,, 440 psi (30 bar) 6 Hz,, 500 psi (35 bar)
17 Hz,, 1000psi (70 bar) 13 Hz,, 1000 psi (70 bar) 9 Hz,, 1000 psi (70 bar)
Servo Pressure 1000 psi (70 bar) nominal
Coil Resistance 1000 ohms
Electrical Input 0-10 ma
Feedback Pot Output, ±3 VDC
19", 15 VDC excitation
Feedback RVDT Output, ±2.4 VDC
19", 15 VDC excitation
Fluid Types All
Fluid Cleanliness NAS 1638, class8 or ISO 17/14
Available Drivers Jupiter High IQ S20-11958
Electrical Connectors supplied with pump

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 69
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Secondary Control Options GOLD CUP® Series - Open & Closed Circuits

CODE DESCRIPTION HYDRAULIC CIRCUIT

TO VANE CHAMBERS

7J6 HIGH IQ COMPENSATOR


PILOT (VPORT)
7J8 DF+ CONTROL
7K6 PROPORTIONAL
7K8 VALVE

CAM POSITION
ELECTRONICS FEEDBACK

COMMAND

TO VANE CHAMBERS

TORQUE LIMITER
--4
OVERRIDE

Parker Hannifin Corporation


Hydraulic Pump Division
70 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Secondary Control Options GOLD CUP® Series - Open & Closed Circuits

TYPICAL PERFORMANCE DESCRIPTION OF OPERATION

The 700 controls are high response displacement controls that use propor-
CAM ANGLE tional directional flow control valves to direct high flow levels to and from the
vane chambers, in order to achieve high stroke rates on the pump A feedback
potentiometer or RVDT (Rotary Variable Differential Transformer) is used to
o
feed back the rocker cam position to the controlling electronics to achieve
19
stable operation.
The 7J6 control uses a proportional directional control valve and a feedback
100%
potentiometer for feedback, the 7J8 uses an RVDT.
100%
COMMAND
The 7K6 control uses proportional directional control valve and a the feedback
potentiometer, but also has a special valve block with a valve in it to shut
o
off the servovalve, so that control may be taken over by a 4A2 control also
19 mounted to the pump as a manual override. The 7K8 is the same, except using
an RVDT.
Specifications for 7J, 7K
P6,7,8 P11,14 P24/30
Hysteresis <±1% <±1% <±1%
Linearity <±0.9% <±0.9% ±0.9%
Step Response 180 ms 300 ms 300 ms
Small Signal Frequency Response 16 Hz, 400 psi (28 bar) 12 Hz,, 440 psi (30 bar) 8Hz,, 500 psi (35 bar)
25 Hz,, 1000 psi (70 bar) 20 Hz,, 1000 psi (70 bar) 10 Hz,, 1000 psi (70 bar)
Ser vo Pressure 1000 psi (70 bar) nominal
Coil Resistance 4 ohms

Feedback Pot Output ±3 VDC at 19º, 15 VDC excitation


Feedback RVDT Output, ±2.4 VDC at 19º, 15 VDC excitation
Fluid Types Al l
Fluid Cleanliness NAS 1638, class 8 or ISO 17/14
Available Drivers Digital EC01 cards (see publication LT3-00055-1)
Electrical Connector

TORQUE
The **4 control option can be added to any other control, except
the 7**, and will limit the amount of torque accepted by the drive
shaft on the pump by reducing displacement if the product of pressure and
flow (displacement) exceed a preset value. This will allow the pump to go to
full stroke, but not at maximum pressure, and it will allow the pump to go to full
o
19
o
pressure, but not at maximum flow. When the condition causing the overload
19
disappears, the pump control reverts to the main displacement control. The
pressure compensator override is always in effect, at all times, and its function
is not effected by this control in any way.
Minimum setting is 25% of maximum input torque.
P (5000 (PSI) x MAX Displacement / 2›

0
15
0
15

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 71
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
6,7,8 Hydraulic Schematics (Closed Circuit) GOLD CUP® Series - Open & Closed Circuits

Series 6, 7 & 8 Information 3/8"-16UNC-2A x 1/2" SOC. SETSCREW


PACKAGE PUMP (NYLOK OR SPOTLOK) INSTALL IN
PORT H. ONLY IF PORT G CONNECTS
EXTERNALLY TO TO PORT H
C
G
D1

D2

DG CONTROL
OPTIONS
FB
FA RECOMMENDED
EXTERNAL FILTER
THE MAXIMUM PRESSURE
BG DROP IN THE FILTER
H CIRCUIT SHOULD NOT
EXCEED 150 PSI UNDER
COLD START CONDITIONS
1/2A
AG

A 1/2A K (OPTIONAL)

40 PSI (2.8 BAR)


RELIEF-OPTIONAL
(RECOMMENDED FOR
CIRCUITS WITH PUMP
SPEEDS INTERMITTENTLY 2A 2A
BELOW 1000 RPM-SEE
PAGE 6)

A A
OPTIONAL LINE

B VB V KG VA A

NOTE: See pages 75 or 76 for the Open


Circuit Pump Operational Notes

PACKAGE MOTOR
D1 D2 FIXED
DISPLACEMENT

PACKAGE MOTOR
VARIABLE
A B DISPLACEMENT
FROM PORT G
ON PUMP
H2
CONTROL OPTIONS
(2A0 SHOWN)
FROM PORT G X A P
ON PUMP H1
Y
B T
OPTIONAL LINE FA FB
D D2 CUSTOMER FURNISHED
DIRECTIONAL VALVE

DG D1

Parker Hannifin Corporation


Hydraulic Pump Division
72 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
11,14 Hydraulic Schematics (Closed Circuit) GOLD CUP® Series - Open & Closed Circuits

Series 11 & 14 Information


PACKAGE PUMP

G2
C

A D1 G
B D2

C DG CONTROL
OPTIONS 1/8-27 NPTF PIPE
FB FA PLUG INSTALLED ONLY
IF PORT "J" CONNECTS
EXTERNALLY TO
PORT "K". INSERT
1/8" PLUG UNDER
BG AG PLUG ON FACE OF
PORT BLOCK

1/2A

A
J
1/2A

40 PSI (2.8 BAR) K


RELIEF-OPTIONAL
(RECOMMENDED FOR
CIRCUITS WITH PUMP
SPEEDS INTERMITTENTLY 2A 2A
BELOW 1000 RPM-SEE
PAGE 6)
RECOMMENDED
C
C
EXTERNAL FILTER
BG2 A A
AG2 THE MAXIMUM PRESSURE
OPTIONAL LINE DROP IN THE FILTER
CIRCUIT SHOULD NOT
EXCEED 150 PSI UNDER
COLD START CONDITIONS
PLUG ON FACE OF PORT BLOCK

B VB V KG VA A

NOTE: See pages 75 or 76 for the Open


Circuit Pump Operational Notes

PACKAGE MOTOR
D D2 FIXED
DISPLACEMENT
C
C

DG D1
D

PACKAGE MOTOR
VARIABLE
A B DISPLACEMENT
AG
FROM PORT G
BG ON PUMP
H2
CONTROL OPTIONS
(2A0 SHOWN)
FROM PORT G X A P
ON PUMP H1
Y
B T
OPTIONAL LINE FA FB
D D2 CUSTOMER FURNISHED
DIRECTIONAL VALVE

DG D1

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 73
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
24,30 Hydraulic Schematics (Closed Circuit) GOLD CUP® Series - Open & Closed Circuits

Series 24 & 30 Information PACKAGE PUMP

C
G
D1 CAUTION: EXTERNAL LINE
MUST BE CONNECTED BETWEEN
PORT G AND H1 PRIOR TO
D2 START-UP OR DAMAGE WILL
OCCUR TO AUX. PUMP

DG CONTROL
OPTIONS
FB
FA

H2

H
1/2A
BG1 AG1

A 1/2A K (OPTIONAL)
RECOMMENDED
40 PSI (2.8 BAR) EXTERNAL FILTER
RELIEF-OPTIONAL
THE MAXIMUM PRESSURE
(RECOMMENDED FOR
DROP IN THE FILTER
CIRCUITS WITH PUMP CIRCUIT SHOULD NOT
SPEEDS INTERMITTENTLY 2A 2A EXCEED 150 PSI UNDER
BELOW 1000 RPM-SEE
COLD START CONDITIONS
PAGE 6)

A A
OPTIONAL LINE BG2 AG2

B VB V KG VA A

NOTE: See pages 75 or 76 for the Open


Circuit Pump Operational Notes

PACKAGE MOTOR
D1 D2 FIXED
DISPLACEMENT

DG D

PACKAGE MOTOR
VARIABLE
A B DISPLACEMENT
FROM PORT G
ON PUMP
H2
CONTROL OPTIONS
(2A0 SHOWN)
FROM PORT G X A P
ON PUMP H1
Y
B T
OPTIONAL LINE FA FB
D D2 CUSTOMER FURNISHED
DIRECTIONAL VALVE

DG D1

Parker Hannifin Corporation


Hydraulic Pump Division
74 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
6,7,8 Hydraulic Schematics (Open Circuit) GOLD CUP® Series - Open & Closed Circuits

3/8"-16 UNC-2A x 1/2" SOC. SETSCREW


Series 6, 7 & 8 Information INSTALLED ONLY IF PORT "G" CONNECTS
EXTERNALLY TO PORT "H".

PORT "H". INSTALL


1/8" PLUG IN PORT "H"

PACKAGE PUMP

C
G
D1

D2
H
DG CONTROL
OPTIONS
FB FA
RECOMMENDED
EXTERNAL FILTER
THE MAXIMUM PRESSURE
BG AG DROP IN THE FILTER
CIRCUIT SHOULD NOT
EXCEED 150 PSI UNDER
COLD START CONDITIONS
1/2A
PLUG ON FACE OF PORT BLOCK

A 1/2A

2A 2A

A A

B VB V KG VA A

RECOMMENDED OPEN CIRCUIT PUMP


CHECK VALVE
pump rotary servo input port port
rotation shaft rotation “A” “B”
input command “A” side R CW inlet outlet
L CCW inlet outlet
input command “B” side R CCW inlet outlet
L CW inlet outlet

NOTES:

1. The auxiliary pump inlet must be connected directly to the reservoir. See page 55
for main pump and auxiliary pump inlet requirements.

2. Case pressure must not exceed inlet pressure by more than 25 psi, 1,7 bar.

3. Maximum allowable inlet (port C) pressure: 200 psi, 13,8 bar.

4. Filters must use bypass valves.

5. Absolute inlet pressure must be increased for the following fluids:


a. 25% for water glycols
b. 35% for phosphate esters

6. A check valve in the outlet line between the pump and load is highly recommended
where hoses, accumulators or other components may decompress when pump is
vented by the compensator.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 75
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
11,14 Hydraulic Schematics (Open Circuit) GOLD CUP® Series - Open & Closed Circuits

Series 11 & 14 Information

PACKAGE PUMP

C
G
D1

D2

DG CONTROL
OPTIONS
FB FA

BG

1/2A

A 1/2A

2A 2A

BG2 A A
AG2

B VB V KG VA A

RECOMMENDED
CHECK VALVE OPEN CIRCUIT PUMP

pump rotary servo input port port


rotation shaft rotation “A” “B”
input command “A” side R CW inlet outlet
L CCW inlet outlet
input command “B” side R CCW inlet outlet
L CW inlet outlet

NOTES:

1. The auxiliary pump inlet must be connected directly to the reservoir. See page 55
for main pump and auxiliary pump inlet requirements.

2. Case pressure must not exceed inlet pressure by more than 25 psi, 1,7 bar.

3. Maximum allowable inlet (port C) pressure: 200 psi, 13,8 bar.

4. Filters must use bypass valves.

5. Absolute inlet pressure must be increased for the following fluids:


a. 25% for water glycols
b. 35% for phosphate esters

6. A check valve in the outlet line between the pump and load is highly recommended
where hoses, accumulators or other components may decompress when pump is
vented by the compensator.

Parker Hannifin Corporation


Hydraulic Pump Division
76 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
®
GOLD CUP Pump Control Combinations GOLD CUP® Series - Open & Closed Circuits

GOLD CUP® PUMP CONTROL COMBINATIONS


102 2M2 *00 2N2 *00 402 5A2 *00 7D6 *00 8A2 *00 8C2 *00 9A2 *00
104 2M2 *01 2N2 *01 404 5A2 *01 7D6 *01 8A2 *01 8C2 *01 9A2 *01
106 2M2 *02 2N2 *02 406 8A2 *02 8C2 *02
2M2 *03 2N2 *03 5A4 *00 8A2 *03 8C2 *03 9A4 *00
108 2M2 *04 2N2 *04 408 5A4 *01 8A2 *04 9A4 *01
2M2 *05 2N2 *05 8C4 *00
2A2 2M2 *06 2N2 *06 4A2 5A6 *00 7D8 *00 8A4 *00 8C4 *01 9A6 *00
2A4 2M2 *07 2N2 *07 4A4 5A6 *01 7D8 *01 8A4 *01 8C4 *02 9A6 *01
2A6 4A6 8A4 *02 8C4 *03
2M4 *00 2N4 *00 7F6 *01 8A4 *03 9A7*00
2A8 2M4 *01 2N4 *01 4A8 8A4 *04 8C6 *00
2M4 *02 2N4 *02 7F8 *01 8C6 *01
2H2 2M4 *03 2N4 *03 4B2 5A8 *00 8A6 *00 8C6 *02 9A8 *00
2H4 2M4 *04 2N4 *04 4B4 5A8 *01 7J6 *00 8A6 *01 8C6 *03 9A8 *01
2H6 2M4 *05 2N4 *05 4B6 7J6 *01 8A6 *02
2M4 *06 2N4 *06 5C2 *00 8A6 *03 9C2 *00
2H8 2M4 *07 2N4 *07 4B8 5C2 *01 8A6 *04 9C2 *01

2M6 *00 2N6 *00 4C2 5C4 *00 9C4 *00


2M6 *01 2N6 *01 4C4 5C4 *01 7J8 *00 9C4 *01
2M6 *02 2N6 *02 4C6 7J8 *01 8C8 *00
2M6 *03 2N6 *03 5C6 *00 8C8 *01 9C6 *00
2M6 *04 2N6 *04 4C8 5C6 *01 7K6 *01 8C8 *02 9C6 *01
2M6 *05 2N6 *05 8C8 *03
2M6 *06 2N6 *06 7K8 *01 8A8 *00
2M6 *07 2N6 *07 8A8 *01
8A8 *02
5C8 *00 8A8 *03 9C8 *00
5C8 *01 8A8 *04 9C8 *01

• Unless otherwise specified on purchase order, the following


factory setting will be used.

Maximum Stops: Full Displacement (both sides of center pumps)


Minimum Stop: Zero Displacement (“V” units & 2A controls only)
2M8 *00 2N8 *00 Pressure Compensator Override: 1000 psi nominal
2M8 *01 2N8 *01 Torque Limiter (**4): P6 @ 1800 rpm = 60 hp nominal
2M8 *02 2N8 *02 (40% of full torque) P7 @ 1800 rpm = 72.5 hp nominal
P8 @ 1800 rpm = 80 hp nominal
2M8 *03 2N8 *03 P11 @ 1800 rpm = 110 hp nominal
2M8 *04 2N8 *04 P14 @ 1800 rpm = 140 hp nominal
2M8 *05 2N8 *05 P24 @ 1800 rpm = 240 hp nominal
P30 @ 1800 rpm = 300 hp nominal
2M8 *06 2N8 *06
2M8 *07 2N8 *07

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 77
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Ordering Code GOLD CUP® Series - Open & Closed Circuits

P
Pump Displacement Type Efficiency Shaft Rotation Seals Design 2 Primary Secondary Control
Controls Controls Location

Code Displacement Code Efficiency Code Rotation


3
6 6.00 in /rev (98 cc/rev) High R Clockwise
H Efficiency
7 7.25 in3/rev (119 cc/rev) L Counterclockwise Code Seals
(P24 only)
8 8.00 in3/rev (131 cc/rev) 1 Nitrile (Buna-N)
Standard
Omit 1 Not ATEX approved.
11 11.0 in3/rev (180 cc/rev) Efficiency 4 EPR 1, 3
2 Assigned by manufacturer
14 14.0 in3/rev (229 cc/rev) 3 Not available when using “5A” or 5 Fluorocarbon
“5C” primary controls. Pump will
24 24.6 in3/rev (403 cc/rev) be unpainted unless otherwise
specified.
30 30.6 in3/rev (501 cc/rev)

Code Primary Controls


Code Type
Omit None (Fixed Displacement only)
F Fixed Displacement, Open/Closed Circuit
-10 Screw Adjustment (Spring Offset to Maximum Displacement)
Fixed Displacement with High Torque
M -2A Cylinder Control w/Adjustable Maximum Volume Stops
Thru-Drive, Open/Closed Circuit
P Variable Displacement, Closed Circuit -2H Cylinder Control – 3-Position (Spring Control with Zero Adjustment)

Variable Displacement with Medium Torque Cylinder Control – 2-Position Electrohydraulic w/Adjustable Maximum
X -2M
Thru-Drive, Closed Circuit Volume Stop (Spring Offset to Maximum Displacement) 1

Variable Displacement with Medium Torque -2N Cylinder Control – 3-Position (Spring Centered) Electrohydraulic 1
S
Thru-Drive & Shuttle Package, Closed Circuit -40 Rotary Servo – Spring Centered
Variable Displacement with High Torque Rotary Servo – Spring Centered w/Adjustable Maximum Volume
R -4A
Thru-Drive, Closed Circuit Stops
Variable Displacement with High Torque -4B Rotary Servo – Spring Centered w/Automatic Brake Control
L
Thru-Drive & Shuttle Package, Closed Circuit
Rotary Servo – Spring centered w/Adjustable Maximum Volume
Variable Displacement, Open Circuit -4C
V Stops & Automatic Brake Control
(P6, 7, 8, 11 & 14 only)
-5A Electrohydraulic Stroker w/Adjustable Maximum Volume Stops 1
Variable Displacement, Open & Closed Circuit
D Electrhydraulic Stroker w/Adjustable Maximum Volume Stops &
(P6, 7 & 8 only) -5C
Automatic Brake Control 1
-7D High IQ with 10 GPM Servo Valve & Volume Indicator 1
-7F High IQ with 10 GPM Servovalve & 4A (Rotary Servo) Control 1
Code Shaft
-7J High IQ with DF+ Valve & Volume Indicator 1
Keyed SAE – Mechanical Shaft Seal (Single
-2
Lip Seal on P6, 7, 8F/M) -7K High IQ with DF+ Valve & 4A (Rotary Servo) Control 1
Splined SAE – Mechanical Shaft Seal -8A Hydraulic Stroker w/Adjustable Maximum Volume Stops
-3
(Single Lip Seal on P6, 7, 8F/M)
Hydraulic Stroker w/Adjustable Maximum Volume Stops & Automatic
Keyed SAE-D (Mounting & Shaft) – -8C
Brake Control
-4 Mechanical Shaft Seal (P6, 7 & 8 only, Single
Lip Seal on Fixed Displacement Pumps) -9A Electrohydraulic Stroker w/Adjustable Maximum Volume Stops 1

Splined SAE-D (Mounting & Shaft) – Electrohydraulic Stroker w/Adjustable Maximum Volume Stops &
-9C
-5 Mechanical Shaft Seal (P6, 7 & 8 only, Single Automatic Brake Control 1
Lip Seal on Fixed Displacement Pumps) -9D Electro-hydraulic stroker w/ adjustable maximum volume stops
-7 Keyed SAE – Double Lip Shaft Seal
-8 Splined SAE – Double Lip Shaft Seal
Code Secondary Controls
-9 Keyed (long) SAE – Double Lip Shaft Seal
None (Fixed Displacement Code Control Location
-10 Keyed (long) SAE – Mechanical Shaft Seal Omit
only)
Omit None (Fixed Displacement only)
2 Volume Indicator
-A Primary Control on Port A Side
Torque Limiter & Volume
4 -B Primary Control on Port B Side
Indicator
Cam Position Feedback
= Omit if not required 6
Potentiometer 1
Cam Position Feedback
7
RVDT (AC)1
Cam Position Feedback R
8 Parker Hannifin Corporation
VDT (DC) 1
Hydraulic Pump Division
78 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Pump Ordering Code GOLD CUP® Series - Open & Closed Circuits

Control & Internal External External Special


Displacement Pump Drive Mounting Modifications
Features

Code Special Modifications


Control Code Control Feature Omit None
CETOP3, NG6 Valve, 110AC/60Hz with -NP No Paint 1
00
Hirschmann Connector 1 ATEX APPROVED PUMP must
-EX
consult engineering.
CETOP3, NG6 Valve, 12VDC with
01
Hirschmann Connector 1 Other Special Modification (example:
bronze caged barrel bearing for
CETOP3, NG6 Valve, 240VAC/50Hz with -M2
02 low viscosity fluids, tandem pumps,
Hirschmann Connector 1 etc.) 1

2M* & CETOP3, NG6 Valve, 110VAC/60Hz, Wiring


03
2N* Box 1
04 CETOP3, NG6 Valve, 12VDC, Wiring Box 1 Code External Mounting
05 CETOP3 (D03, NG6) Interface, No Valve 1 Omit No External Drive Required

CETOP3, NG6 Valve, 24VDC with 0 No External Pump Mounted


06
Hirschmann Connector 1 External Pump Mounted (must be separately
1
specified) – Requires Special Modification “-M2” 1
CETOP3, NG6 Valve, 110VAC/50Hz with
07 2 ATEX Externally Mounted Pump
Hirschmann Connector 1
00 With Deadband 1
5**
01 Without Deadband 1
00 Without Manual Override Shutoff 1 Code External Drive
7** With Manual Override Shutoff 1 Omit None 1
01
(required for D, F, J & K primary options) M Blanking plate – for P6, 7, 8, 11, 14S/X only
00 75-350 PSI (5-24 Bar) A SAE-A (SAE 82-2) – P6, 7, 8, 11, 14S/X/R/L/M only
01 75-435 PSI (5-30 Bar) SAE-B (SAE 101-2) – P6, 7, 8, 11, 14, 24, 30/S/X/R/L/M
B
SAE-B (SAE 101-4) – P11, 14, 24, 30R/L/M
8** 02 100-300 PSI (7-26 Bar) SAE-C (SAE 127-2) – P6, 7, 8, 11, 14, 24, 30R/L/M & P24, 30S/X
C
03 150-400 PSI (10-28 Bar) SAE-C (SAE 127-4) – P11, 14, 24, 30R/L/M
D SAE-D (SAE 152-4) – P11, 14, 24, 30R/L/M only
04 75-250 PSI (5-17 Bar)
E SAE-E (SAE 165-4) – P11, 14, 24, 30R/L/M only
00 24VDC
9** F SAE-F (SAE 177-4) – P24, 30R/L/M only
01 12VDC
All
00 None 1
Other
Code Internal Pump
Pump Code Reduced Displacement 1.07 in3/rev (17.5 cc/rev) – P6, 7, 8P/S/X/V/D & P11, 14V only**
00 Standard Cam (19°) -0 2.14 in3/rev (35 cc/rev) – P11, 14P/S/X only**
2.81 in3/rev (46 cc.rev) – P24, 30P/S/X only (standard)**
3
P6 with 17° Cam – 5.3 in /rev (87cc/rev) 1.61 in3/rev (26.4 cc/rev) – P24, 30P/S/X only
P7 with 17° Cam – 6.4 in3/rec (105 cc/rev) -1
(auxiliary external replenishing flow required)
P8 with 17° Cam – 7.1 in3/rev (116 cc/rev)
10 P11 with 17° Cam – 9.7 in3/rev (160 cc/rev) 1.05 in3/rev (17.2 cc/rev) – P24, 30P/S/X only
-2
P14 with 17° Cam – 12.5 in3/rev (205 cc/rev) (auxiliary external replenishing flow required)
P24 with 17° Cam – 22.0 in3/rev (360 cc/rev) -3 3.56 in3/rev (58.3 cc/rev) – P24, 30P/S/X only
P**F P30 with 17° Cam – 27.2 in3/rev (446 cc/rev)
& -4 4.84 in3/rev (79.3 cc/rev) – P24, 30P/S/X only
P**M P6 with 15° Cam – 4.6 in3/rev (76 cc/rev)
-5 5.42 in3/rev (88.8 cc/rev) – P24, 30P/S/X only
P7 with 15° Cam – 5.6 in3/rev (92 cc/rev)
20 P8 with 15° Cam – 6.2 in3/rev (102 cc/rev) -6 6.10 in3/rev (100.0 cc/rev) – P24, 30P/S/X only
P11 with 15° Cam – 8.5 in3/rev (140 cc/rev)
-X No Internal Pump (standard on P*R/L/F/M)
P14 with 15° Cam – 10.9 in3/rev (179 cc/rev)
** Omit code if no external drive is required.
P6 with 13° Cam – 4.0 in3/rev (66 cc/rev)
30 P7 with 13° Cam – 4.8 in3/rev (79 cc/rev)
P8 with 13° Cam – 5.3 in3/rev (88 cc/rev)

= Omit if not required

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 79
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Notes GOLD CUP® Series - Open & Closed Circuits

Notes

Parker Hannifin Corporation


Hydraulic Pump Division
80 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
®
GOLD CUP Motor Control Combinations GOLD CUP® Series - Open & Closed Circuits

GOLD CUP® MOTOR CONTROL COMBINATIONS


2A0 *2M3 *0 5A0 *0 8A0 *0 9A0 *0
*2A3 *2M3 *1 5A0 *1 8A0 *1 9A0 *1
*2A5 *2M3 *2
2A6 *2M3 *3 5A3 *0 8A3 *0 9A3 *0
*2M3 *4 5A3 *1 8A3 *1 9A3 *1
2A8 *2M3 *5
*2M3 *6 5A5 *0 8A5 *0 9A5 *0
2M0 *0 5A5 *1 8A5 *1 9A5 *1
2M0 *1
2M0 *2 *2M5 *0 5A6 *0 8A6 *0 9A6 *0
2M0 *3 *2M5 *1 5A6 *1 8A6 *1 9A6 *1
2M0 *4 *2M5 *2
2M0 *5 *2M5 *3
2M0 *6 *2M5 *4
*2M5 *5
*2M5 *6 5A8 *0 8A8 *0 9A8 *0
5A8 *1 8A8 *1 9A8 *1

*2M6 *0 9D0*0
*2M6 *1 9D081
*2M6 *2
*2M6 *3
*2M6 *4
*2M6 *5
*2M6 *6

• Not available for M24 or M30

Unless otherwise specified on purchase order, the following


factory setting will be used.
Maximum Stop: Full Displacement
*2M8 *0 Minimum Stop: Approximately 30% Displacement
*2M8 *1 Reverse Pressure Compensator Override (**3 & **5): 1000 psi
*2M8 *2 nominal
*2M8 *3
*2M8 *4
*2M8 *5
*2M8 *6

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 81
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Motor Ordering Code GOLD CUP® Series - Open & Closed Circuits

M
Motor Displacement Type Efficiency Shaft Rotation Seals Design 2 Primary Secondary Control
Controls Controls Location

Code Efficiency Code Rotation


Code Displacement High N Bi-directional
H Efficiency
6 6.00 in3/rev (98cc/rev) Code Seals
(M24 only)
7 7.25 in3/rev (119 cc/rev) 1 Not ATEX approved. 1 Nitrile (Buna-N)
Standard 2 Assigned by manufacturer.
Omit
8 8.00 in3/rev (131 cc/rev) Efficiency 3 Not available when using “5A” 4 EPR 3
3 primary control. Motor will be
11 11.0 in /rev (180 cc/rev) 5 Fluorocarbon
unpainted unless otherwise
14 14.0 in3/rev (229 cc/rev) specified.

24 24.6 in3/rev (403 cc/rev)


30 30.6 in3/rev (501 cc/rev) Code Primary Controls
Omit None (Fixed Displacement only)
-2A Cylinder Control w/Adjustable Maximum Volume Stops
Code Type
Cylinder Control – 2-Position Electrohydraulic w/Ad-
F Fixed Displacement -2M justable Maximum Volume Stop (Spring Offset to
Maximum Displacement)1
G Fixed Displacement with Shuttle Package
Electrohydraulic Stroker w/Adjustable Maximum
M Fixed Displacement with Thru-Drive -5A
Volume Stops1
Fixed Displacement with Thru-Drive & Shuttle Hydraulic Stroker w/Adjustable Maximum Volume
N -8A
Package Stops
V Variable Displacement Electrohydraulic Stroker w/Adjustable Maximum
-9A
H Variable Displacement with Shuttle Package Volume Stops1

R Variable Displacement with Thru-Drive


Variable Displacement with Thru-Drive & Code Secondary Controls
L
Shuttle Package
Omit None (Fixed Displacement only)
0 Volume Indicator
Reverse Compensator (spring offset to maximum displace-
3
ment) + Volume Indicator
Code Shaft Reverse Compensator (spring offset to minimum displacement)
5
+ Volume Indicator
Keyed SAE – Mechanical Shaft Seal (Single
-2
Lip Seal on M6, 7, 8F/G/M/N) 6 Cam Position Feedback Potentiometer1
Splined SAE – Mechanical Shaft Seal 7 Cam Position Feedback RVDT (AC)1
-3
(Single Lip Seal on M6, 7, 8F/G/M/N)
8 Cam Position Feedback RVDT (DC)1
Keyed SAE-D (Mounting & Shaft) –
Reverse Compensator (3) + Cam Position Feedback Potentiom-
-4 Mechanical Shaft Seal (M6, 7 & 8 only, Single U
eter (6)1
Lip Seal on Fixed Displacement Motors)
W Reverse Compensator (3) + Cam Position Feedback RVDT (8)1
Splined SAE-D (Mounting & Shaft) –
-5 Mechanical Shaft Seal (P6, 7 & 8 only, Single Reverse Compensator (5) + Cam Position Feedback Potentiom-
Lip Seal on Fixed Displacement Motors) X
eter (6)1
-7 Keyed SAE – Double Lip Shaft Seal Z Reverse Compensator (5) + Cam Position Feedback RVDT (8)1
-8 Splined SAE – Double Lip Shaft Seal
-9 Keyed (long) SAE – Double Lip Shaft Seal
-10 Keyed (long) SAE – Mechanical Shaft Seal

Code Control Location


Omit None (Fixed Displacement only)
-A Primary Control on Port A Side
-B Primary Control on Port B Side
= Omit if not required

Parker Hannifin Corporation


Hydraulic Pump Division
82 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Motor Ordering Code GOLD CUP® Series - Open & Closed Circuits

Control & Shuttle External External Special


Displacement Valve Drive Mounting Modifications
Features Features

Code Special Modifications


Control Code Control Feature Omit None
CETOP3, NG6 Valve, 110AC/60Hz with -NP No Paint
0
Hirschmann Connector1 Other Special Modification
(example: bronze caged barrel
CETOP3, NG6 Valve, 12VDC with -M2
1 bearing for low viscosity fluids,
Hirschmann Connector1
tandem motors, etc.)
CETOP3, NG6 Valve, 240VAC/50Hz with ATEX APPROVED PUMP
2 -EX
Hirschmann Connector1 must consult engineering.
CETOP3, NG6 Valve, 110VAC/60Hz,
2M 3
Wiring Box1
Code External Mounting
4 CETOP3, NG6 Valve, 12VDC, Wiring Box1
0 No External Motor Mounted
5 CETOP3 (D03, NG6) Interface, No Valve1 External Motor Mounted (must be
CETOP3, NG6 Valve, 24VDC with 1 separately specified) – Requires Special
6 Modification “-M2”
Hirschmann Connector1
2 ATEX Externally Mounted Motor
CETOP3, NG6 Valve, 110VAC/50Hz with
7
Hirschmann Connector1
0 With Deadband1 Code External Drive
5A Omit None (M*F/G/V/H units only)
1 Without Deadband1
-A SAE-A (SAE 82-2) – M6, 7, 8, 11, 14M/N/R/L only
0 75-250 PSI (5-17 Bar)
8A SAE-B (SAE 101-2) – M6, 7, 8M/N/R/L
-B
1 250-450 PSI (17-31 Bar) SAE-B (SAE 101-2 & 101-4) – M11, 14, 24, 30M/N/R/L
0 24VDC1 SAE-C (SAE 127-2) – M6, 7, 8M/N/R/L
-C
9A SAE-C (SAE 127-2 & 127-4) – M11, 14, 24, 30M/N/R/L
1 12VDC1
-D SAE-D (SAE 152-4) – M11, 14, 24, 30M/N/R/L only
All Other 0 None -E SAE-E (SAE 165-4) – M11, 14, 24, 30M/N/R/L only
Motor Code Reduced Displacement -F SAE-F (SAE 177-4) – M24, 30M/N/R/L only
0 Standard Cam (19°) -M Blanking Plate-less Coupling
3
M6 with 17° Cam – 5.3 in /rev (87cc/rev)
M7 with 17° Cam – 6.4 in3/rec (105 cc/rev)
M8 with 17° Cam – 7.1 in3/rev (116 cc/rev) Code Shuttle Valve Features
1 M11 with 17° Cam – 9.7 in3/rev (160 cc/rev)
Omit M*F/M/V/R Motors only
M14 with 17° Cam – 12.5 in3/rev (205 cc/rev)
M*F M24 with 17° Cam – 22.0 in3/rev (360 cc/rev) 0 Without Orifices
M*G M30 with 17° Cam – 27.2 in3/rev (446 cc/rev)
2 With Orifices
M*M M6 with 15° Cam – 4.6 in3/rev (76 cc/rev)
M*N M7 with 15° Cam – 5.6 in3/rev (92 cc/rev)
2 M8 with 15° Cam – 6.2 in3/rev (102 cc/rev)
M11 with 15° Cam – 8.5 in3/rev (140 cc/rev)
M14 with 15° Cam – 10.9 in3/rev (179 cc/rev)
M6 with 13° Cam – 4.0 in3/rev (66 cc/rev)
3 M7 with 13° Cam – 4.8 in3/rev (79 cc/rev)
M8 with 13° Cam – 5.3 in3/rev (88 cc/rev)

= Omit if not required

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 83
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Notes GOLD CUP® Series - Open & Closed Circuits

Notes

Parker Hannifin Corporation


Hydraulic Pump Division
84 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Notes GOLD CUP® Series - Open & Closed Circuits

Notes

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 85
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Notes GOLD CUP® Series - Open & Closed Circuits

Notes

Parker Hannifin Corporation


Hydraulic Pump Division
86 Marysville, Ohio USA
HY28-2667-01/GC/NA,EU Hydrostatic Transmission Piston Pumps
Offer of Sale GOLD CUP® Series - Open & Closed Circuits

The items described in this document and other documents and descriptions provided by Parker Hannifin Corporation, Hydraulics Group, and its authorized distributors (“Seller”) are
hereby offered for sale at prices to be established by Seller. This offer and its acceptance by any customer (“Buyer”) shall be governed by all of the following Terms and Conditions. Buyer’s
order for any item described in its document, when communicated to Seller verbally, or in writing, shall constitute acceptance of this offer. All goods or work described will be referred to as
“Products”.

1. Terms and Conditions. Seller’s willingness to offer Products, or accept an order for 11. Buyer’s Obligation; Rights of Seller. To secure payment of all sums due or otherwise,
Products, to or from Buyer is expressly conditioned on Buyer’s assent to these Terms and Seller shall retain a security interest in the goods delivered and this agreement shall be
Conditions and to the terms and conditions found on-line at www.parker.com/saleterms/. deemed a Security Agreement under the Uniform Commercial Code. Buyer authorizes
Seller objects to any contrary or additional term or condition of Buyer’s order or any other Seller as its attorney to execute and file on Buyer’s behalf all documents Seller deems
document issued by Buyer. necessary to perfect its security interest. Seller shall have a security interest in, and lien
2. Price Adjustments; Payments. Prices stated on the reverse side or preceding pages upon, any property of Buyer in Seller’s possession as security for the payment of any
of this document are valid for 30 days. After 30 days, Seller may change prices to reflect any amounts owed to Seller by Buyer.
increase in its costs resulting from state, federal or local legislation, price increases from its 12. Improper Use and Indemnity. Buyer shall indemnify, defend, and hold Seller harmless
suppliers, or any change in the rate, charge, or classification of any carrier. The prices stated from any claim, liability, damages, lawsuits, and costs (including attorney fees), whether for
on the reverse or preceding pages of this document do not include any sales, use, or other personal injury, property damage, patent, trademark or copyright infringement or any other
taxes unless so stated specifically. Unless otherwise specified by Seller, all prices are F.O.B. claim, brought by or incurred by Buyer, Buyer’s employees, or any other person, arising out
Seller’s facility, and payment is due 30 days from the date of invoice. After 30 days, Buyer of: (a) improper selection, improper application or other misuse of Products purchased by
shall pay interest on any unpaid invoices at the rate of 1.5% per month or the maximum Buyer from Seller; (b) any act or omission, negligent or otherwise, of Buyer; (c) Seller’s use
allowable rate under applicable law. of patterns, plans, drawings, or specifications furnished by Buyer to manufacture Product;
3. Delivery Dates; Title and Risk; Shipment. All delivery dates are approximate and or (d) Buyer’s failure to comply with these terms and conditions. Seller shall not indemnify
Seller shall not be responsible for any damages resulting from any delay. Regardless of the Buyer under any circumstance except as otherwise provided.
manner of shipment, title to any products and risk of loss or damage shall pass to Buyer 13. Cancellations and Changes. Orders shall not be subject to cancellation or change by
upon tender to the carrier at Seller’s facility (i.e., when it’s on the truck, it’s yours). Unless Buyer for any reason, except with Seller’s written consent and upon terms that will indemnify,
otherwise stated, Seller may exercise its judgment in choosing the carrier and means of defend and hold Seller harmless against all direct, incidental and consequential loss or
delivery. No deferment of shipment at Buyers’ request beyond the respective dates indicated damage. Seller may change product features, specifications, designs and availability with
will be made except on terms that will indemnify, defend and hold Seller harmless against notice to Buyer.
all loss and additional expense. Buyer shall be responsible for any additional shipping 14. Limitation on Assignment. Buyer may not assign its rights or obligations under this
charges incurred by Seller due to Buyer’s changes in shipping, product specifications or in agreement without the prior written consent of Seller.
accordance with Section 13, herein. 15. Entire Agreement. This agreement contains the entire agreement between the Buyer
4. Warranty. Seller warrants that the Products sold hereunder shall be free from defects in and Seller and constitutes the final, complete and exclusive expression of the terms of the
material or workmanship for a period of eighteen months from the date of delivery to Buyer. agreement. All prior or contemporaneous written or oral agreements or negotiations with
The prices charged for Seller’s products are based upon the exclusive limited warranty respect to the subject matter are herein merged.
stated above, and upon the following disclaimer: DISCLAIMER OF WARRANTY: THIS 16. Waiver and Severability. Failure to enforce any provision of this agreement will not
WARRANTY COMPRISES THE SOLE AND ENTIRE WARRANTY PERTAINING TO waive that provision nor will any such failure prejudice Seller’s right to enforce that provision
PRODUCTS PROVIDED HEREUNDER. SELLER DISCLAIMS ALL OTHER WARRAN- in the future. Invalidation of any provision of this agreement by legislation or other rule of law
TIES, EXPRESS AND IMPLIED, INCLUDING MERCHANTABILITY AND FITNESS FOR shall not invalidate any other provision herein. The remaining provisions of this agreement
A PARTICULAR PURPOSE. will remain in full force and effect.
5. Claims; Commencement of Actions. Buyer shall promptly inspect all Products upon 17. Termination. This agreement may be terminated by Seller for any reason and at any
delivery. No claims for shortages will be allowed unless reported to the Seller within 10 days time by giving Buyer thirty (30) days written notice of termination. In addition, Seller may by
of delivery. No other claims against Seller will be allowed unless asserted in writing within written notice immediately terminate this agreement for the following: (a) Buyer commits a
60 days after delivery or, in the case of an alleged breach of warranty, within 30 days after breach of any provision of this agreement (b) the appointment of a trustee, receiver or custo-
the date within the warranty period on which the defect is or should have been discovered dian for all or any part of Buyer’s property (c) the filing of a petition for relief in bankruptcy
by Buyer. Any action based upon breach of this agreement or upon any other claim arising of the other Party on its own behalf, or by a third party (d) an assignment for the benefit of
out of this sale (other than an action by Seller for any amount due to Seller from Buyer) must creditors, or (e) the dissolution or liquidation of the Buyer.
be commenced within thirteen months from the date of tender of delivery by Seller or, for 18. Governing Law. This agreement and the sale and delivery of all Products hereunder
a cause of action based upon an alleged breach of warranty, within thirteen months from shall be deemed to have taken place in and shall be governed and construed in accordance
the date within the warranty period on which the defect is or should have been discovered with the laws of the State of Ohio, as applicable to contracts executed and wholly performed
by Buyer. therein and without regard to conflicts of laws principles. Buyer irrevocably agrees and
6. LIMITATION OF LIABILITY. UPON NOTIFICATION, SELLER WILL, AT ITS OPTION, consents to the exclusive jurisdiction and venue of the courts of Cuyahoga County, Ohio
REPAIR OR REPLACE A DEFECTIVE PRODUCT, OR REFUND THE PURCHASE with respect to any dispute, controversy or claim arising out of or relating to this agreement.
PRICE. IN NO EVENT SHALL SELLER BE LIABLE TO BUYER FOR ANY SPECIAL, Disputes between the parties shall not be settled by arbitration unless, after a dispute has
INDIRECT, INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF, OR AS arisen, both parties expressly agree in writing to arbitrate the dispute.
THE RESULT OF, THE SALE, DELIVERY, NON-DELIVERY, SERVICING, USE OR LOSS 19. Indemnity for Infringement of Intellectual Property Rights. Seller shall have no
OF USE OF THE PRODUCTS OR ANY PART THEREOF, OR FOR ANY CHARGES OR liability for infringement of any patents, trademarks, copyrights, trade dress, trade secrets
EXPENSES OF ANY NATURE INCURRED WITHOUT SELLER’S WRITTEN CONSENT, or similar rights except as provided in this Section. Seller will defend and indemnify Buyer
EVEN IF SELLER HAS BEEN NEGLIGENT, WHETHER IN CONTRACT, TORT OR against allegations of infringement of U.S. patents, U.S. trademarks, copyrights, trade dress
OTHER LEGAL THEORY. IN NO EVENT SHALL SELLER’S LIABILITY UNDER ANY and trade secrets (“Intellectual Property Rights”). Seller will defend at its expense and will
CLAIM MADE BY BUYER EXCEED THE PURCHASE PRICE OF THE PRODUCTS. pay the cost of any settlement or damages awarded in an action brought against Buyer
7. Contingencies. Seller shall not be liable for any default or delay in performance if based on an allegation that a Product sold pursuant to this Agreement infringes the Intel-
caused by circumstances beyond the reasonable control of Seller. lectual Property Rights of a third party. Seller’s obligation to defend and indemnify Buyer
8. User Responsibility. The user, through its own analysis and testing, is solely responsible is contingent on Buyer notifying Seller within ten (10) days after Buyer becomes aware of
for making the final selection of the system and Product and assuring that all performance, such allegations of infringement, and Seller having sole control over the defense of any
endurance, maintenance, safety and warning requirements of the application are met. The allegations or actions including all negotiations for settlement or compromise. If a Product is
user must analyze all aspects of the application and follow applicable industry standards and subject to a claim that it infringes the Intellectual Property Rights of a third party, Seller may,
Product information. If Seller provides Product or system options, the user is responsible for at its sole expense and option, procure for Buyer the right to continue using the Product,
determining that such data and specifications are suitable and sufficient for all applications replace or modify the Product so as to make it noninfringing, or offer to accept return of
and reasonably foreseeable uses of the Products or systems. the Product and return the purchase price less a reasonable allowance for depreciation.
9. Loss to Buyer’s Property. Any designs, tools, patterns, materials, drawings, confiden- Notwithstanding the foregoing, Seller shall have no liability for claims of infringement based
tial information or equipment furnished by Buyer or any other items which become Buyer’s on information provided by Buyer, or directed to Products delivered hereunder for which
property, may be considered obsolete and may be destroyed by Seller after two consecutive the designs are specified in whole or part by Buyer, or infringements resulting from the
years have elapsed without Buyer placing an order for the items which are manufactured modification, combination or use in a system of any Product sold hereunder. The foregoing
using such property. Seller shall not be responsible for any loss or damage to such property provisions of this Section shall constitute Seller’s sole and exclusive liability and Buyer’s sole
while it is in Seller’s possession or control. and exclusive remedy for infringement of Intellectual Property Rights.
10. Special Tooling. A tooling charge may be imposed for any special tooling, including 20. Taxes. Unless otherwise indicated, all prices and charges are exclusive of excise, sales,
without limitation, dies, fixtures, molds and patterns, acquired to manufacture Products. use, property, occupational or like taxes which may be imposed by any taxing authority upon
Such special tooling shall be and remain Seller’s property notwithstanding payment of any the manufacture, sale or delivery of Products.
charges by Buyer. In no event will Buyer acquire any interest in apparatus belonging to 21. Equal Opportunity Clause. For the performance of government contracts and where
Seller which is utilized in the manufacture of the Products, even if such apparatus has been dollar value of the Products exceed $10,000, the equal employment opportunity clauses in
specially converted or adapted for such manufacture and notwithstanding any charges paid Executive Order 11246, VEVRAA, and 41 C.F.R. §§ 60-1.4(a), 60-741.5(a), and 60-250.4,
by Buyer. Unless otherwise agreed, Seller shall have the right to alter, discard or otherwise are hereby incorporated.
dispose of any special tooling or other property in its sole discretion at any time.

Parker Hannifin Corporation


Hydraulic Pump Division
Marysville, Ohio USA 87
North America Truck The Netherlands Korea
USA Oldenzaal Seoul
Industrial Tel: (31) 541 585000 Tel: (82) 2 559 0400
USA Eastern Region
Chicago Region Cleveland, OH Norway Malaysia
Naperville, IL Tel: (440) 519 1125 Ski Subang Jaya
Tel: (630) 964 0796 Western Region Tel: (47) 64 91 10 00 Tel: (60) 3 5638 1476
Great Lakes Region San Ramon, CA Poland New Zealand
Fairlawn, OH Tel: (925) 735 9573 Warsaw Mt. Wellington
Tel: (330) 670 2680 Canada Tel: (48) 22 57 32400 Tel: (64) 9 574 1744
Northeast Region Milton, Ontario Portugal Japan
Lebanon, NJ Tel: (905) 693 3000
Tel: (908) 236 4121 Leca da Palmeira Tokyo
México Tel: (351) 22 999 7360 Tel: (81) 3 6408 3900
Pacific Region Apodaca, N.L.
Buena Park, CA Romania Singapore
Tel: (52) 81 8156 6000 Bucharest
Tel: (714) 228 2509 Jurong Town
Tel: (40) 21 252 1382 Tel: (65) 6 887 6300
Southern Region Europe
Alpharetta, GA Russia Taiwan
Austria Moscow
Tel: (770) 619 9767 Taipei
Wiener Neustadt Tel: (7) 495 580 9145
Canada Tel: (43) 2622 23501 0 Tel: (886) 2 2298 8987
Milton, Ontario Slovenia
Belgium Novo Mesto Thailand
Tel: (905) 693 3000 Bangkok
Nivelles Tel: (386) 7 337 6650
México Tel: (32) 67 280 900 Tel: (662) 717 8140
Toluca, Edo. de México Czech Republic and Spain
Tel: (52) 72 2275 4200 Slovakia Madrid Middle East
Klecany Tel: (34) 91 675 7300 United Arab Emirates
Mobile Tel: (420) 284 083 111 Sweden Abu Dhabi
USA Denmark Spanga Tel: (971) 2 678 8587
Global Mobile Ballerup Tel: (46) 8 597 95000
Lincolnshire, IL Tel: (45) 4356 0400 Ukraine Latin America
Tel: (847) 821 1500 Finland Kiev Pan American Division
Central Region Vantaa Tel: (380) 44 494 2731 Miami, FL
Lincolnshire, IL Tel: (358) 20 753 2500 United Kingdom Tel: (305) 470 8800
Tel: (847) 821 1500 France Warwick, Argentina
Eastern Region Contamine-sur-Arve Tel: (44) 1926 317878 Buenos Aires
North Canton, OH Tel: (33) 4 50 25 80 25 Tel: (54) 33 2744 4129
Tel: (330) 284 3355 Germany Asia Pacific
Midwest Region Brazil
Kaarst Australia Cachoeirinha RS
Hiawatha, IA Tel: (49) 2131 4016 0
Tel: (319) 393 1221 Castle Hill Tel: (55) 51 3470 9144
Greece Tel: (61) 2 9634 7777
Southern Region Athens Venezuela
Aledo, TX Tel: (30) 210 933 6450 China Caracas
Tel: (817) 441 1794 Beijing Tel: (58) 212 238 5422
Hungary Tel: (86) 10 6561 0520
Western Region
Buena Park, CA Budapest Shanghai Africa
Tel: (714) 228 2509 Tel: (36) 1 220 4155 Tel: (86) 21 5031 2525 South Africa
Canada Ireland Kempton Park
County Dublin, Baldonnell Hong Kong
Milton, Ontario Tel: (852) 2428 8008 Tel: (27) 11 961 0700
Tel: (905) 693 3000 Tel: (353) 1 466 6370
India
México Italy
Mahape, Navi Mumbai
Apodaca, N.L. Corsico, Milano Tel: (91) 22 5613 7081
Tel: (52) 81 8156 6000 Tel: (39) 02 45 19 21

© 2010 Parker Hannifin Corporation, all rights reserved This literature replaces ALL previous literature
3/10 NP HY28-2667-01/GC/NA,EU
Effective: March 01, 2010
Parker Hannifin Corporation
Hydraulic Pump Division
14249 Industrial Parkway
Marysville, OH 43040 USA
phone 937.644.4532
fax 937.642.3639
www.parkerhpd.com