Sie sind auf Seite 1von 27

BILL NO.

31
MOLASSES STORAGE

TA2459 Lesaffre Garuda 1/27 3e73-a0f7-78d2-ebbf.xlsx-Cover


Item BILL NO. 31 SUMMARY RUPIAHS
No. MOLASSES STORAGE

SUMMARY

31.1 DEMOLITION N/A

31.2 EARTHWORK -

31.3 CONCRETE -

31.4 MASONRY -

31.5 METALS -

31.7 THERMAL AND MOISTURE PROTECTION -

31.8 DOORS AND WINDOWS -

31.9. FINISHES -

31.10 SPECIALITIES N/A

31.11 MECHANICAL WORKS N/A

31.2 ELECTRICAL WORKS -

31.3 HVAC WORKS N/A

BILL NO. 31
CARRIED TO SUMMARY -

TA2459 Lesaffre Garuda 2/27 3e73-a0f7-78d2-ebbf.xlsx-Sum


Item BILL NO. 31
31.1 DEMOLITION Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

31.1 DEMOLITION
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. N/A

TA2459 Lesaffre Garuda 3/27 3e73-a0f7-78d2-ebbf.xlsx-2.1


Item BILL NO. 31 Qty Unit Rate Rupiahs
31.2 EARTHWORK
No. MOLASSES STORAGE

31.2.1 CUT OFF PILE HEAD

Cut off pile head as drawings

A Spun pile, dia. 800mm nos

31.2.2 EARTHWORK

Excavation, disposal and backfill in any material including rock or hard


material, working space at parimeter items as defined; Excavating, starting
from stripped level, trenches to receive depth as pecified (insite area)

B To Footings m3

C To Slab on Ground Incl. slab guard room m3

D To Tank Foundation m3

E To Wall m3

31.2.3 BASE COURSES

Compacted of subgrade to 95% Standard Proctor Density as specified

F To Footings m2

G To Slab on Ground Incl. slab guard room m2

H To Tank Foundation m2

J To Tie Beam m2

Sandfill 100mm thick as specified

K To Footings m2

L To Slab on Ground Incl. slab guard room m2

M To Tank Foundation m2

N To Tie Beam m2

31.2.4 TERMITE CONTROL

Termite control to soil; The protection against termites by spraying an


insecticide on the soil or on the fill before placing the vapor and after
building completed and importing landfill; undertaken by an approved
specialist; (5 years quarantee to be given) as specified.

O To Footings m2

P To Slab on Ground Incl. slab guard room m2

Q To Tank Foundation m2

R To Wall m2

TA2459 Lesaffre Garuda 4/27 3e73-a0f7-78d2-ebbf.xlsx-2.2


Item BILL NO. 31 Qty Unit Rate Rupiahs
31.2 EARTHWORK
No. MOLASSES STORAGE

To Collection Rp. -

31.2.5 OTHERS

Plastic sheet

A To Footings m2

B To Slab on Ground Incl. slab guard room m2

C To Tank Foundation m2

D To Tie Beam m2

To Collection Rp. -

COLLECTIONS

Page 31.2 /1

Page 31.2 /2 -

TA2459 Lesaffre Garuda 5/27 3e73-a0f7-78d2-ebbf.xlsx-2.2


Item BILL NO. 31 Qty Unit Rate Rupiahs
31.2 EARTHWORK
No. MOLASSES STORAGE

31.2 EARTHWORK
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 6/27 3e73-a0f7-78d2-ebbf.xlsx-2.2


Item BILL NO. 31
31.3 CONCRETE Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

31.3.1 FORMWORK

31.3.1.1 IN GROUND FORMWORK

The design, certification, construction and performance of the formwork,


falsework and backpropping shall be the responsibilty of Contractor.
Proposed method of installation and removal of formwork is to be submitted
to the Superintendent for comment prior to work being carried out as per
dwg note.
In ground formwork as follows; permanent formwork system for in-place
concrete, concrete hollow block 100mm thick, finish starting at/from any
level and including rebates or grooves formers as described to

A To Footings m2 -

B To Slab on Ground m2 -

31.3.1.2 UPPER STRUCTURE FORMWORK

Smooth-Formed Finished concrete, plywood, metal, or other approved panel


materials, finish starting at/from any level and rebates or groove formers as
specified

C To Slab m2 -

D To Tank Foundation m2 -

E To Tie Beam and Beam m2 -

F To Column m2 -

G To Wall Incl. bundwall m2 -

H To Stair m2 -

31.3.2 CONCRETE

In-Situ Concrete

In-situ concrete designed mix Grade 30 Mpa, (K-350) NFA; ± 20mm


aggregate, vibrated with standard flatness as described ;

I To Footings m3 -

J To Slab on Ground Incl. slab guard room m3 -

K To Tank Foundation m3 -

L To Tie Beam and Beam m3 -

M To Column m3 -

N To Wall Incl. bundwall m3 -

O To Stair m3 -

TA2459 Lesaffre Garuda 7/27 3e73-a0f7-78d2-ebbf.xlsx-2.3


Item BILL NO. 31
31.3 CONCRETE Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

To Collection Rp. -

31.3.2 CONCRETE, CONT'D

Lean Concrete

Plain in-situ concrete, designed mix grade f'c= Mpa,(K-125), 40mm


aggregate, 50mm thick as described,

A To Footings m2 -

B To Slab on Ground m2 -

C To Tank Foundation m2 -

D To Tie Beam m2 -

31.3.3 REINFORCEMENT

Manufacture reinforcement bars is according to "Manual of Standard


Practice" CRSI's as follows; supply, cleaned, measurement, positioning,
setting and install. Reinforcement measure include joint dowel bars,
bolsters, chairs, spacers and other device for spacing, supporting and
fastening reinforcing bars and welded wire reinforcement in place.

Wiremesh M8-150 as specified

E To Slab on Ground 2 layers m2 -

F To Stair - Bordes slab 2 layers m2 -

Reinforcing bars is Grade 60/420 deformed or Grade BJTD 40 deformed.


round mild steel, as described in

G Dia. 13mm, To Footings kg -

H Dia. 10mm, To Slab on Ground Incl. slab guard room kg -

I Dia. 22mm, To Tank Foundation kg -

J Dia. 13mm, To Tie Beam and Beam kg -

K Dia. 10mm, To Tie Beam and Beam kg -

L Dia. 13mm, To Column kg -

M Dia. 10mm, To Column kg -

N Dia. 10mm, To Wall Incl. bundwall kg -

O Dia. 8mm, To Wall Incl. bundwall kg -

P Dia. 13mm, To Stair kg -

Q Dia. 10mm, To Stair kg -

TA2459 Lesaffre Garuda 8/27 3e73-a0f7-78d2-ebbf.xlsx-2.3


Item BILL NO. 31
31.3 CONCRETE Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

To Collection Rp. -

COLLECTIONS

Page 31.3 /1 -

Page 31.3 /2 -

TA2459 Lesaffre Garuda 9/27 3e73-a0f7-78d2-ebbf.xlsx-2.3


Item BILL NO. 31
31.3 CONCRETE Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

31.3 CONCRETE
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 10/27 3e73-a0f7-78d2-ebbf.xlsx-2.3


Item BILL NO. 31
31.4 MASONRY Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.4.1 UNIT MASONRY

Supply and Install Autoclaved aerated concrete block wall with mortar;
including reinforced concrete bonding ties, anchorage, latching, stiffener
columns and lintels beams as required, all in accordancce with drawings and
specifications
A To Wall 150mm thick External Wall m2

B To Wall 150mm thick Internal Wall m2

31.4.2 PLASTERED

Plaster; Mortar instant trowelled smooth with and including cement coating
instant as described

C To Wall 150mm thick m2 -

31.4 MASONRY
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 11/27 3e73-a0f7-78d2-ebbf.xlsx-2.4


Item BILL NO. 31
31.4 MASONRY Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

TA2459 Lesaffre Garuda 12/27 3e73-a0f7-78d2-ebbf.xlsx-2.4


Item BILL NO. 31 31.5 METALS
Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.5.1 RAILING

Supply and Install steel pipe railing including handrail support and knee
railing complete with kick plate, anchor bolt and all necessary fixing
accessories as drawings and specifications

A To stair m

31.5.2 SUNDRIES

Supply and install hot dipped galvanized steel angle complet with all
fixing accessories and support as drawing and specification

B L 50.50.5 m

Supply and install steel grating complete with metal angle support grating
including all fixing accessories and support as drawing and specification

C To Gutter m

D To Sumpit 600x600mm nos

E To Sumpit 1000x1000mm nos

31.5 METALS

TA2459 Lesaffre Garuda 13/27 3e73-a0f7-78d2-ebbf.xlsx-2.5


Item BILL NO. 31 31.5 METALS
Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 14/27 3e73-a0f7-78d2-ebbf.xlsx-2.5


Item BILL NO. 31 31.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. MOLASSES STORAGE PROTECTION

31.7.1 ROOF SPECIALITIES

Supply and Install down pipe complete with overflow, steel clamp, support,
fitting, bracket, steel unp, and all fixing accessories; all in accordance with
drawings and specifications

A PVC Downpipe Ø4" m

B Roof Drain nos

Supply and install concrete waterproofing liquid membrane complete with


screeding, accessories and support; all in accordance with manufacturer's
instruction, drawings, and specifications

C To Roof m2

31.7 THERMAL AND MOISTURE PROTECTION


CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 15/27 3e73-a0f7-78d2-ebbf.xlsx-2.7


Item BILL NO. 31 31.7 THERMAL AND MOISTURE Qty Unit Rate Rupiahs
No. MOLASSES STORAGE PROTECTION

TA2459 Lesaffre Garuda 16/27 3e73-a0f7-78d2-ebbf.xlsx-2.7


Item BILL NO. 31
31.8 DOORS AND WINDOWS Qty. Unit Rate Rupiahs
No. MOLASSES STORAGE

31.8.1 DOORS

Supply and install aluminium door including laminated tempered glass +


clear glass, frames, hardwares, treshold, steel plate, and all fixing accessories
and supports as drawings and specifications

A 31.DR.001 nos

31.8.3 WINDOWS

Supply and install aluminium window complete with laminated tempered


glass + clear glass, hardwares, and all necessary components, fixing,
accessories as drawing and specification.

B 31.WA.001 nos

C 31.WB.002 nos

D 31.WB.003 nos

31.8 DOORS AND WINDOWS


CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 17/27 3e73-a0f7-78d2-ebbf.xlsx-2.8


Item BILL NO. 31
31.9. FINISHES Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.9.1 FLOOR FINISHES

Epoxy; all in accordance with manufacturer's instruction, drawings, and


specifications

A To Floor m2

Supply and install Homogenous Tile complete with screed, gape grouting
and all in accordance with manufactured instruction applied: all in
accordance with drawings and specifications

B To Floor m2

C To Skirting m

Concrete Broom Finish; all in accordance with manufacturer's instruction,


drawings, and specifications

D To Floor m2

31.9.2 WALL FINISHES

Prepare smooth and apply epoxy paint finish, in accordance with


manufacturer's recommendations, as specified to face of :

E Applied to concrete walls m2

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

F Applied to plastered autoclaved concrete walls (Internal Wall) m2

Prepare smooth and apply waterbased wethershield emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

G Applied to plastered autoclaved concrete walls (External Wall) m2

H Applied to parapet wall

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

I Applied to concrete walls m2

31.9.3 CEILING FINISHES

Prepare smooth and apply waterbased acrylic emulsion paint finish, in


accordance with manufacturer's recommendations, as specified to face of :

J To Concrete Ceiling m2

Prepare smooth and apply skimcoat, in accordance with manufacturer's


recommendations, as drawing and specification

K To Concrete Ceiling m2

31.9. FINISHES
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 18/27 3e73-a0f7-78d2-ebbf.xlsx-2.9


Item BILL NO. 31
31.9. FINISHES Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

TA2459 Lesaffre Garuda 19/27 3e73-a0f7-78d2-ebbf.xlsx-2.9


Item BILL NO. 31
31.10 SPECIALITIES Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.10 SPECIALITIES
CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. N/A

TA2459 Lesaffre Garuda 20/27 3e73-a0f7-78d2-ebbf.xlsx-2.10


Item BILL NO. 31
31.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.11 MECHANICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. N/A

TA2459 Lesaffre Garuda 21/27 3e73-a0f7-78d2-ebbf.xlsx-2.11


Item BILL NO. 31
31.11 MECHANICAL WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

TA2459 Lesaffre Garuda 22/27 3e73-a0f7-78d2-ebbf.xlsx-2.11


Item BILL NO. 31
31.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31,12 ELECTRICAL WORKS

31.12.1 SUB DISTRIBUTION BOARDS


Supply, Install and Testing Commissioning the following Sub Distribution board
fix in position includes circuit breaker, board, busbar, digital multimeter,
contactor, surge arrester, potensial transformer, current transformer, indicator
lamp, fuse, loto, star / stop push button, and all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

A 31DB01 no

31.12.2 MAIN AND SUB-MAINS CABLES


Supply and Install the following Main and Sub-Mains circuit distribution cable
run & fixed on cable tray/ladders including all necessary accessories in
arcondance to the technical spesification as shown on drawing, as described : -

B From SDB…. to 31DB01 m by other package

31.12.3 LIGHTING FIXTURES & POWER OUTLET


Supply and Install the following light fittings including tubes or lamps fixed in
position complete with all accessories and support in accordance with the
technical specification and drawings, as described :-

C Waterproof LED 40W, 220V, IP65 mounted on steel pipe 2.5m height Ø50mm no

D Flood light LED 100W, 9500lm, mounted on steel pipe 2.5m height Ø50mm no

E Surface downlight 16W, 220V, minimum 1.200lm no

Supply and Install the following switches including provision of steel/metal box
and all accessories accordance with the technical specification and drawings, as
described :-

F Double gang, 1 way switch, 10A no

Supply and Install lighting & switch cables from sub circuit to final circuit
including grounding system and all neccessary accessories accordance with the
technical specification and drawings, as described :-

G Cabling point from local panel (NYM 3C x 2.5 mm² run-in and with PVC high no
impact conduit) to; lighting and switch

POWER OUTLET
Supply and Install the following power outlet including provision of steel/metal
box and all accessories accordance with the Technical Specification and
drawings, as described :-

H General socket outlet, wall mounted, 16A, 250V, single gang no

I Industrial socket outlet, mounted on the front panel door, 16A, 250V, IP65 no

J Industrial socket outlet, mounted on the front panel door, 32A, 400V, IP65

To Collection Rp. -

TA2459 Lesaffre Garuda 23/27 3e73-a0f7-78d2-ebbf.xlsx-2.12


Item BILL NO. 31
31.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

TA2459 Lesaffre Garuda 24/27 3e73-a0f7-78d2-ebbf.xlsx-2.12


Item BILL NO. 31
31.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

21.12.4 TRAYS AND LADDERS


Supply and Install hot dip galvanized tray and ladder 2mm thickness include
jointing, elbow, tee, fixing accessories and hangers and all necessary accessories
accordance with the technical specification and drawings, as described :-

Electrical

A Cable tray 300x100mm m

B Wiremesh tray 300x100mm m

C Wiremesh tray 200x100mm m

21.12.5 GROUNDING & LIGHTNING PROTECTION SYSTEM

Supply and Install Grounding system for panel and equipment complete with
support and all neccessary accessories accordance with the technical
specification and drawings, as described :-

D Earth pit, Conductor clamp and rod electrode, dia 19mm x 3000 length no

E Earthing bonding bar (copper bar) 40x3mm thk, c/w isolator no

F BC 70mm2, grounding cable for main/mesh earthing c/w connector and m


grounding lug

To Collection Rp. -

COLLECTIONS

Page 31.12 /1 -

Page 31.12 /2 -

31.2 ELECTRICAL WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. -

TA2459 Lesaffre Garuda 25/27 3e73-a0f7-78d2-ebbf.xlsx-2.12


Item BILL NO. 31
31.2 ELECTRICAL WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

TA2459 Lesaffre Garuda 26/27 3e73-a0f7-78d2-ebbf.xlsx-2.12


Item BILL NO. 31
31.3 HVAC WORKS Qty. Unit Rate Rupiahs
No MOLASSES STORAGE

31.3 HVAC WORKS


CARRIED TO SUMMARY AT END OF BILL NO. 31 Rp. N/A

TA2459 Lesaffre Garuda 27/27 3e73-a0f7-78d2-ebbf.xlsx-2.13

Das könnte Ihnen auch gefallen