Sie sind auf Seite 1von 1

PROJECT

BATANGAS
INTERNATIONAL
PORT TERMINAL
FROM MERALCO MAIN LINE
BATANGAS BAS PORT, BARANGAY SANTA CLARA,
BATANGAS CITY

OWNER

MERALCO MAIN LINE


MERALCO MAIN LINE
ASIAN TERMINALS INCORPORATED

--
3 - PVC PIPE 110mmØ PROJECT MANAGER

3-150mm2 15kv XLPE CABLE


FUSE CUT-OUTS RESIDENT ENGINEER

PHILIPPINE
DCCD
ENGINEERING

BATANGAS PORT PORTS


AUTHORITY
CORPORATION
CONSULTING ENGINEERS, SINCE 1957
SOL Bldg., 112 Amorsolo St., Legaspi Village, Makati City
TEL. 892-45-86 TO 89 TEL. 818-20-33

--
PROJECT MANAGER

ARCHITECT

NW Steel Technologies Inc.


30 PARAGUAY ST. LOYOLA GRAND VILLAS, QUEZON CITY
NW
LEETS TEL. (02) 828 6867 FAX. 433 2480

ARCHITECT

CIVIL

NW Steel Technologies Inc.


30 PARAGUAY ST. LOYOLA GRAND VILLAS, QUEZON CITY
NW
LEETS TEL. (02) 828 6867 FAX. 433 2480

AFW
11 JOSE MARIA FRANCISCO O. MONTEJO
CIVIL ENGINEER

MECHANICAL

NW Steel Technologies Inc.


30 PARAGUAY ST. LOYOLA GRAND VILLAS, QUEZON CITY
NW
LEETS TEL. (02) 828 6867 FAX. 433 2480

SIDE VIEW
PROPOSE FIRST PRIVATE POLE LAYOUT
PROF. MECHANICAL ENGINEER

01 SANITARY

E-2A SCALE: NTS NW Steel Technologies Inc.


30 PARAGUAY ST. LOYOLA GRAND VILLAS, QUEZON CITY
NW
LEETS TEL. (02) 828 6867 FAX. 433 2480

SANITARY ENGINEER

FIRE PROTECTION

NW Steel Technologies Inc.


31 34 30 PARAGUAY ST. LOYOLA GRAND VILLAS, QUEZON CITY
45 50 SOLDERLESS CONNECTOR FOR #2 CU.
NW
LEETS TEL. (02) 828 6867 FAX. 433 2480

300 1200
480
720
300 48 LIGHTNING ITEM DESCRIPTION
480 250 19 29 ARRESTERS 1 CT MOUNTING CHANNEL
51 CURRENT LIMITING FUSE
300

FIRE PROTECTION ENGINEER


130 130 52 TERMINAL LUG
2 PT MOUNTING CHANNEL
7 14 16 22 30 3 CT BASE SUPPORT
53 EVERDUR LOCKWASHER FOR 12 DIA. BOLT STRUCTURAL
300

TO PROTECTIVE 54 EVERDUR NUT FOR 12 DIA. BOLT


46 47 50 4 PT BASE SUPPORT
14 27
DEVICE
31 34
55 EVERDUR BOLT 12 DIA, x 40 w/o NUT AND WASHER NW Steel Technologies Inc.
7 SEE INSET DRWG.
37 41 43 45 56 EVERDUR BOLT, 9.5 DIA. x 45 w/ NUT AND WASHER 30 PARAGUAY ST. LOYOLA GRAND VILLAS, QUEZON CITY
37 41 43 6 ALLEY ARM BRACE, 2400 LG. NW
LEETS TEL. (02) 828 6867 FAX. 433 2480
2250

TO PROTECTIVE GUT TO ANCHOR 57 POWER FUSE ASSEMBLY


14 3 1 DEVICE 7 CROSS ARM BRACE
300

48 58 FUSE REFILL
66 99 8 CROSS ARM, 3000 mm. LG.
26 20 15 59 POWER FUSE PROF. STRUCTURAL ENGINEER

29 11 KEYPLAN
6 15 95 10 MACHINE BOLT, 16 DIA x 450
2250
2400

FUSE 11 MACHINE BOLT, 16 DIA x 400


94 80 79 69 15 28 81 80 79 77 93 CUT-OUTS 12 MACHINE BOLT, 16 DIA x 350
84 85 86 87 88 68
89 90 91 25 13 14 MACHINE BOLT, 16 DIA x 50
66 CURRENT TRANSFORMER
150

70 15 MACHINE BOLT, 16 DIA x 40


67 POTENTIAL TRANSFORMER
68 GI CONDUIT, 25 MM IPS X 3 LENGTH
16 MACHINE BOLT, 16 DIA x 150
G.L. 71 69 CONDULETM MALL. IRON, 25mm DIA.,
CONDUCTOR 17 DOUBLE ARMING BOLT, 16 DIA. x 600
4000

70 COMMON NAIL, 80MM


(WHERE ADJACENT TO VEHICULAR

49 50 46 SUPPORT
TRAFFIC, INCREASE TO 7000)

TO ENTRANCE CAP
USE U-25-T 78 19 DOUBLE ARMING BOLT, 16 DIA. x 450
71 PIPE STRAP, MALL. IRON FOR 25mm DIA. REVISIONS
5500 mm. (Min.)

72 CONDUIT STRAP
12 4 2 21 15 79 20 DOUBLE ARMING BOLT, 16 DIA. x 400 NO. DATE DESCRIPTION
73 CONDUIT ELBOW FOR 25mm DIA.
21 DOUBLE ARMING BOLT, 16 DIA. x 350
82 99 80 MESSENGER WIRE 22 LAG SCREW, 16 DIA. x 125
74 CONDUIT BUSHING, 25mm DIA.
6100

73 74 75 76 75 CONDUIT COUPLING, 25mm DIA.


3000 (MIN.)

USE G-I-WC 23 LAG SCREW, 16 DIA. x 100


81 CABLE HOLDER 76 CONDUIT LOCKNUT, 25mm DIA.
FOR GROUNDING
CONCRETE POLE MOUNTING 77 CONDULET FERALOY TYPE LB, 25mm DIA.
BRACKET
25 HOLE CLAMP 279 DIA.
13.5M (45FT) 78 CONDULET FERALOY TYPE TB, 25MM DIA.
26 HOLE CLAMP 254 DIA.
1 3 6 12 G.L.
INSULATED 79 BLANK COVER FOR 25mm DIA. CONDULET
SERVICE CABLE 27 HOLE CLAMP 229 DIA.
15 21 23 28 ALLEY ARM BRACE CLAMP
80 RUBBER GASKET FOR 25mm DIA. CONDULET
3660 81 GALV. NIPPLE, 25mm DIA. x 100mm
29 SQUARE WASHER FOR 16 DIA. BOLT
3600 82 MOUNTING COLLAR
30 ROUND WASHER FOR 12 DIA. BOLT
29 19 10 8 93 CABLE HANGER 31 NEMA MTG. BRACKET
83 MTG. BAR ADAPTER
84 METER CABINET
SPINNING WIRE 32 FUSE CUTOUT
130

85 POLYPHASE KW-HR METER 2 ELEMENTS, 3 DIA. - 4W


FRONT ELEVATION 33 FUSE LINK
96 67 w/ CONTACTS
890

40 39 34 LIGHTINING ARRESTER
86 POLYPHASE KW-HR METER 2 ELEMENTS, 3 DIA. -4W
480

35 BOLT EYE FOR 16 DIA. BOLT SHEET CONTENTS


w/o CONTACTS
36 BALL CLEVIS
1370

39 36 35 40 THREE-BOLT 87 RECORDING DEMAND METER, 120V SIDE VIEW PROPOSE FIRST PRIVATE POLE LAYOUT
GUY CLAMP 37 STEEL PIN PRIMARY METERING DETAIL
130

MESSENGER WIRE
88 PHASE SHIFTER, 3 DIA. -4W VAR METER w/ TEST SW. CUSTOMER FIRST PRIVATE POLE DETAIL
(GALVANIZED 89 TEST BLOCK 10 POLES, w/ GLASS COVER
35 36 1145 1370 1145
96 95 GUY WIRE)
39 STRAIN CLAMP
90 STOVE BOLT, 25mm LONG
40 SUSPENSION INSULATOR
OVAL EYE BOLT
TOP VIEW 41 PIN INSULATOR
91 WIRE #12 SOLID, TYPE TW
FRONT VIEW SIDE VIEW
92 WIRE #12 STRANDED, FLAMENOL
PURPOSE OF ISSUANCE
93 CT & PT WIRE LEAD, 2/0 CU.
43 TIE WIRE #4 CU.
94 FRICTION TAPE, 75mm WIDTH

02 PRIMARY METERING DETAIL 45 PRIMARY LEAD #4/0 CU., BARE STRD. 95


96
COMP. CONNECTOR #2/0 CU. TO PRIMARY
SOLDERLESS CONNECTOR FOR #2/0 CU. DRAWN: SHEET NUMBER

E-2A SCALE: NTS 03 CUSTOMER FIRST PRIVATE POLE DETAIL


SCALE: NTS
46
47
48
GROUNDING LEAD #2 CU. BARE
STAPLE FOR GROUND WIRE
COMP. CONNECTOR #4/0 CU. TO PRIMARY
97
98
99
CONDULET TYPE LB, 25mm DIA.
GALV. NIPPLE, 25mm DIA.
MACHINE BOLT 12 DIA x 40
DATE:

REVISED:
E-2A
E-2A 49 COMP. CONNECTOR #2 CU. TO NEUTRAL CHECKED:

PROJ. NUMBER:
NOTES:
· ANY DISCREPANCY MUST BE VERIFIED WITH THE ARCHITECT AND THE ENGINEER.
· PROVIDE FIREPROOFING SEALANT TO ALL PIPES & DUCTS PENETRATING WALLS AND SLABS.
· VERIFY ACTUAL SITE/FLOOR ELEVATIONS PRIOR TO IMPLEMENTATION.
FINAL FLOOR ELEVATION IS SUBJECT FOR ACTUAL SURVEY.
· COORDINATE WITH ARCHITECTURAL, STRUCTURAL & OTHER TRADES FOR FINAL LOCATION
AQUILINO T. RIVERA
PROF. ELECTRICAL ENGINEER
OF ALL CEILING COMPONENTS.
P.R.C. Reg. No.: 2384 DATE: 01/2/2020
P.T.R. No.: 8117131 DATE: 10/04/2023
T.I.N.: 146-271-015 PLACE: MAKATI CITY