THE STRUCTURES SHOWN ON THESE DRAWINGS HAVE BEEN DESIGNED FOR THE
FOLLOWING LOADS:
NOTES:
SHEET SIZE A3 PACIFIC DEVELOPMENT & CONSTRUCTION
SCALE: AS SHOWN ADDITIONS & ALTERATIONS TO RESIDENCE
ISSUED FOR CONSTRUCTION CERTIFICATE
ORIGINAL SURVEY BY 14 D'ARCY AVE, APPIN (LOT 22 DP 246207)
DO NOT SCALE DRAWINGS. USE FIGURED
N/A PROPOSED SHED
DIMENSIONS ONLY. ALL DISCREPANCIES TO BE NOTES & SPECIFICATIONS
REPORTED TO PRASCON AUSTRALIA OFFICE. SURVEY DATE: N/A
COORDS & DATUM FILENAME: JOB NUMBER SHEET NUMBER REVISION
A ISSUED FOR CONSTRUCTION CERTIFICATE 30.11.2020 KD AH AH AH TN
REV AMENDMENT / REASON FOR ISSUE DATE DES. DWN. DWGCHK. VERIFIED APPROVED -
20236.DWG 20236 01 A
© PRASCON AUSTRALIA PTY LTD
C
3
NOTES:
C C
1. GEOTECHNICAL INVESTIGATION HAS NOT BEEN CARRIED OUT. PRASCON MUST INSPECT
3 3 THE FOUNDATION PRIOR TO LAYING REINFORCEMENT FOR FOOTINGS.
2. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS AND THE
SPECIFICATION.
3. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE NOTED.
4. ALL DISCREPANCY SHALL BE REFERRED TO PRASCON AND ANY VARIATIONS SHALL BE
APPROVED BY PRASCON PRIOR TO PROCEEDING WITH THE WORK.
3L11TM - 2000 5. ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL BE VERIFIED ON
C
LONG TRIMMER 3 3L11TM - 2000 SITE BY THE CONTRACTOR BEFORE CONSTRUCTION AND FABRICATION ARE COMMENCED.
LONG TRIMMER 6. PRASCON'S DRAWINGS ARE NOT TO BE SCALED. NO RESPONSIBILITY WILL BE TAKEN BY
PRASCON FOR DIMENSIONS OBTAINED BY SCALING THE DRAWINGS.
C C
3 3
LEGENDS:
STARTING POD
SLAB RIBS
POD EXTENSION - INSERT EXTRA POD OFFCUT TO MATCH LENGTH (1500 MAX)
D D A A
3 3 3 3
1500 mm DEEP FROM NATURAL GROUND LEVEL X 400 mm DIAMETER 20 MPa PLAIN
CONCRETE BORED PIER
8955
8850
REINFORCEMENTS:
2235
B
3
150
6115
7125
9810
NOTES:
SHEET SIZE A3 PACIFIC DEVELOPMENT & CONSTRUCTION
SCALE: AS SHOWN ADDITIONS & ALTERATIONS TO RESIDENCE
ISSUED FOR CONSTRUCTION CERTIFICATE
ORIGINAL SURVEY BY 14 D'ARCY AVE, APPIN (LOT 22 DP 246207)
DO NOT SCALE DRAWINGS. USE FIGURED
N/A PROPOSED SHED
DIMENSIONS ONLY. ALL DISCREPANCIES TO BE SLAB PLAN
REPORTED TO PRASCON AUSTRALIA OFFICE. SURVEY DATE: N/A
COORDS & DATUM FILENAME: JOB NUMBER SHEET NUMBER REVISION
A ISSUED FOR CONSTRUCTION CERTIFICATE 30.11.2020 KD AH AH AH TN
REV AMENDMENT / REASON FOR ISSUE DATE DES. DWN. DWGCHK. VERIFIED APPROVED -
20236.DWG 20236 02 A
© PRASCON AUSTRALIA PTY LTD
SL82 MESH PIPE WRAPPED WITH 2N12 - 1000 LONG
10 ABLEFLEX TRIMMER
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH
40
ARCHITECTURAL DRAWINGS AND THE SPECIFICATION.
2. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE NOTED.
PIPE WRAPPED WITH
10 ABLEFLEX
3. ALL DISCREPANCY SHALL BE REFERRED TO PRASCON AND
1:1 SLOPE
1-N12; ANY VARIATIONS SHALL BE APPROVED BY PRASCON PRIOR
400 400 40 BOTTOM COVER TO PROCEEDING WITH THE WORK.
1-N12 TO LAP; 4. ALL DIMENSIONS RELEVANT TO SETTING OUT AND
40 BOTTOM COVER 200 LAP OFF-SITE WORK SHALL BE VERIFIED ON SITE BY THE
200 LAP L11TM300 OR 3-N12 CONTRACTOR BEFORE CONSTRUCTION AND FABRICATION
TYPICAL PIPE (DIAMETER < 150 mm) ARE COMMENCED.
TYPICAL PIPE (DIAMETER < 150 mm) PENETRATION 5. PRASCON'S DRAWINGS ARE NOT TO BE SCALED. NO
THROUGH RIB BEAM DETAIL PENETRATION THROUGH GROUND SLAB DETAIL RESPONSIBILITY WILL BE TAKEN BY PRASCON FOR
(PLAN VIEW) TYPICAL FOUNDATION CORNER DETAIL DIMENSIONS OBTAINED BY SCALING THE DRAWINGS.
(ELEVATION VIEW)
SCALE 1: 25
SCALE 1: 25 (PLAN VIEW)
SCALE 1: 25
85
REFER
PLAN
REFER
PLAN
110
400 400 150 MIN.
400
L11TM200 OR 3-N12 PERIMETER; 1-N12;
1-N12 TO LAP; 40 BOTTOM COVER 40 BOTTOM COVER
40 BOTTOM COVER
300 1090 110 MIN 200 mm CONCRETE
UNDERLAY
TYPICAL WAFFLE SLAB 'T' INTERSECTION DETAIL TYPICAL EDGE & RIB BEAM DETAIL
(PLAN VIEW) TYPICAL PIPE (DIAMETER < 150 mm)
SCALE 1: 25
PENETRATION THROUGH RIB BEAM DETAIL A SECTION A
2 SCALE 1: 25
(PLAN VIEW)
SCALE 1: 25
TIMBER FRAME TO
AS 1684
15 MIN CHAMFER EDGE
TIMBER FRAME TO WAFFLE POD LOCALISED BEND
AS 1684 SL82 MESH; DOWN MESH
30 TOP COVER 15
POD EXTENSION - INSERT WAFFLE POD
85
EXTRA N12 PERIMETER;
EXTRA POD OFFCUT TO SL82 MESH;
REFER
30 TOP COVER
PLAN
INTERNAL FINISHED FLOOR LEVEL
REFER
30 TOP COVER
PLAN
MATCH LENGTH (1500 MAX) WAFFLE POD
85
1000 OR LESS
SL82 MESH;
REFER
PLAN
BEND 90o
85
NOTES:
SHEET SIZE A3 PACIFIC DEVELOPMENT & CONSTRUCTION
SCALE: AS SHOWN ADDITIONS & ALTERATIONS TO RESIDENCE
ISSUED FOR CONSTRUCTION CERTIFICATE
ORIGINAL SURVEY BY 14 D'ARCY AVE, APPIN (LOT 22 DP 246207)
DO NOT SCALE DRAWINGS. USE FIGURED
N/A PROPOSED SHED
DIMENSIONS ONLY. ALL DISCREPANCIES TO BE SLAB DETAIL
REPORTED TO PRASCON AUSTRALIA OFFICE. SURVEY DATE: N/A
COORDS & DATUM FILENAME: JOB NUMBER SHEET NUMBER REVISION
A ISSUED FOR CONSTRUCTION CERTIFICATE 30.11.2020 KD AH AH AH TN
REV AMENDMENT / REASON FOR ISSUE DATE DES. DWN. DWGCHK. VERIFIED APPROVED -
20236.DWG 20236 03 A
© PRASCON AUSTRALIA PTY LTD
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ARCHITECTURAL
DRAWINGS AND THE SPECIFICATION.
C1 C1 2. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE NOTED.
3. ALL DISCREPANCY SHALL BE REFERRED TO PRASCON AND ANY
VARIATIONS SHALL BE APPROVED BY PRASCON PRIOR TO PROCEEDING
WITH THE WORK.
4. ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL
BE VERIFIED ON SITE BY THE CONTRACTOR BEFORE CONSTRUCTION
AND FABRICATION ARE COMMENCED.
5. PRASCON'S DRAWINGS ARE NOT TO BE SCALED. NO RESPONSIBILITY
WILL BE TAKEN BY PRASCON FOR DIMENSIONS OBTAINED BY SCALING
THE DRAWINGS.
6. ALL OTHER FLOOR JOIST, WALL AND SLAB NOT SHOWN ON THE DRAWING
SHALL BE TIMBER CONSTRUCTED AS PER AS 1684.
7. ALL WELDING SHALL BE CONTINUOUS.
MEMBER SCHEDULE
8955
45
10 PLATE WITH
6 CFW TO PFC f12 HOLES FOR M10 BOLT
CONNECTION INTO C1 COLUMN
86
200PFC
B1 END SECTION
10 PLATE WITH
6 CFW TO C1 COLUMN
25
f14 HOLES FOR M12 DYNABOLT
B1
C1 C1
30 45
89 SHS 5.0
2235
2835
7125
NOTES:
SHEET SIZE A3 PACIFIC DEVELOPMENT & CONSTRUCTION
SCALE: AS SHOWN ADDITIONS & ALTERATIONS TO RESIDENCE
ISSUED FOR CONSTRUCTION CERTIFICATE
ORIGINAL SURVEY BY 14 D'ARCY AVE, APPIN (LOT 22 DP 246207)
DO NOT SCALE DRAWINGS. USE FIGURED
N/A PROPOSED SHED
DIMENSIONS ONLY. ALL DISCREPANCIES TO BE FIRST FLOOR STEEL FRAMING PLAN
REPORTED TO PRASCON AUSTRALIA OFFICE. SURVEY DATE: N/A
COORDS & DATUM FILENAME: JOB NUMBER SHEET NUMBER REVISION
A ISSUED FOR CONSTRUCTION CERTIFICATE 30.11.2020 KD AH AH AH TN
REV AMENDMENT / REASON FOR ISSUE DATE DES. DWN. DWGCHK. VERIFIED APPROVED -
20236.DWG 20236 04 A
© PRASCON AUSTRALIA PTY LTD
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ARCHITECTURAL
DRAWINGS AND THE SPECIFICATION.
C1 C1 2. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE NOTED.
3. ALL DISCREPANCY SHALL BE REFERRED TO PRASCON AND ANY
VARIATIONS SHALL BE APPROVED BY PRASCON PRIOR TO PROCEEDING
WITH THE WORK.
4. ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL
BE VERIFIED ON SITE BY THE CONTRACTOR BEFORE CONSTRUCTION
AND FABRICATION ARE COMMENCED.
5. PRASCON'S DRAWINGS ARE NOT TO BE SCALED. NO RESPONSIBILITY
WILL BE TAKEN BY PRASCON FOR DIMENSIONS OBTAINED BY SCALING
THE DRAWINGS.
6. ALL OTHER FLOOR JOIST, WALL AND SLAB NOT SHOWN ON THE DRAWING
SHALL BE TIMBER CONSTRUCTED AS PER AS 1684.
7. ALL WELDING SHALL BE CONTINUOUS.
MEMBER SCHEDULE
B2 B2
8955
250PFC
M12 BOLT
300
NOTCHED TIMBER RAFTER OVER PFC
100
10 TOP PLATE 6CFW ON C1
10 PLATE 6CFW ON C1
89 SHS 5.0
C1 C1
SECTION
2235
2835
7125
NOTES:
SHEET SIZE A3 PACIFIC DEVELOPMENT & CONSTRUCTION
SCALE: AS SHOWN ADDITIONS & ALTERATIONS TO RESIDENCE
ISSUED FOR CONSTRUCTION CERTIFICATE
ORIGINAL SURVEY BY 14 D'ARCY AVE, APPIN (LOT 22 DP 246207)
DO NOT SCALE DRAWINGS. USE FIGURED
N/A PROPOSED SHED
DIMENSIONS ONLY. ALL DISCREPANCIES TO BE ROOF STEEL FRAMING PLAN
REPORTED TO PRASCON AUSTRALIA OFFICE. SURVEY DATE: N/A
COORDS & DATUM FILENAME: JOB NUMBER SHEET NUMBER REVISION
A ISSUED FOR CONSTRUCTION CERTIFICATE 30.11.2020 KD AH AH AH TN
REV AMENDMENT / REASON FOR ISSUE DATE DES. DWN. DWGCHK. VERIFIED APPROVED -
20236.DWG 20236 05 A
© PRASCON AUSTRALIA PTY LTD