Sie sind auf Seite 1von 5

DESIGN REQUIREMENTS

THE STRUCTURES SHOWN ON THESE DRAWINGS HAVE BEEN DESIGNED FOR THE
FOLLOWING LOADS:

WIND LOAD REGION A


EARTHQUAKE DESIGN CLASSIFICATION DOMESTIC
SITE CLASSIFICATION M

LIVE LOADS ON GROUND FLOOR,


FIRST FLOOR & SECOND FLOOR 1.5 kPa
LIVE LOADS ON ROOF 0.25 kPa
PARTITION WALLS 1.0 kPa
CEILING 1.0 kPa

NOTES:
SHEET SIZE A3 PACIFIC DEVELOPMENT & CONSTRUCTION
SCALE: AS SHOWN ADDITIONS & ALTERATIONS TO RESIDENCE
ISSUED FOR CONSTRUCTION CERTIFICATE
ORIGINAL SURVEY BY 14 D'ARCY AVE, APPIN (LOT 22 DP 246207)
DO NOT SCALE DRAWINGS. USE FIGURED
N/A PROPOSED SHED
DIMENSIONS ONLY. ALL DISCREPANCIES TO BE NOTES & SPECIFICATIONS
REPORTED TO PRASCON AUSTRALIA OFFICE. SURVEY DATE: N/A
COORDS & DATUM FILENAME: JOB NUMBER SHEET NUMBER REVISION
A ISSUED FOR CONSTRUCTION CERTIFICATE 30.11.2020 KD AH AH AH TN
REV AMENDMENT / REASON FOR ISSUE DATE DES. DWN. DWGCHK. VERIFIED APPROVED -
20236.DWG 20236 01 A
© PRASCON AUSTRALIA PTY LTD
C
3

NOTES:
C C
1. GEOTECHNICAL INVESTIGATION HAS NOT BEEN CARRIED OUT. PRASCON MUST INSPECT
3 3 THE FOUNDATION PRIOR TO LAYING REINFORCEMENT FOR FOOTINGS.
2. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ARCHITECTURAL DRAWINGS AND THE
SPECIFICATION.
3. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE NOTED.
4. ALL DISCREPANCY SHALL BE REFERRED TO PRASCON AND ANY VARIATIONS SHALL BE
APPROVED BY PRASCON PRIOR TO PROCEEDING WITH THE WORK.
3L11TM - 2000 5. ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL BE VERIFIED ON
C
LONG TRIMMER 3 3L11TM - 2000 SITE BY THE CONTRACTOR BEFORE CONSTRUCTION AND FABRICATION ARE COMMENCED.
LONG TRIMMER 6. PRASCON'S DRAWINGS ARE NOT TO BE SCALED. NO RESPONSIBILITY WILL BE TAKEN BY
PRASCON FOR DIMENSIONS OBTAINED BY SCALING THE DRAWINGS.
C C
3 3

LEGENDS:

STARTING POD

SLAB RIBS

MIN. SLAB THICKNESS


85
300
WAFFLE POD THICKNESS

POD EXTENSION - INSERT EXTRA POD OFFCUT TO MATCH LENGTH (1500 MAX)
D D A A
3 3 3 3

1500 mm DEEP FROM NATURAL GROUND LEVEL X 400 mm DIAMETER 20 MPa PLAIN
CONCRETE BORED PIER
8955

8850

RIB & EDGE BEAM DIMENSIONS (UNLESS OTHERWISE NOTED IN PLAN)


85
300
INTERNAL RIB: 110 mm WIDE

EDGE BEAM: 300 mm WIDE

FIREWALL BEAM: 400 mm WIDE


6355

REINFORCEMENTS:

SLAB REINFORCEMENT: SL82; 30 mm TOP COVER

RIB REINFORCEMENT BAR: N12; 40 mm BOTTOM COVER

PERIMETER EDGE BEAM REINFORCEMENT: 3L11TM; 40 mm BOTTOM COVER


3955

2235

B
3
150

150 APPROVED LOCATION FOR


B POD EXTENSION
3
2835 INSERT EXTRA POD OFFCUT
TO MATCH LENGTH
3715 (SEE DETAIL 'B')

6115

7125

9810

PROPOSED WAFFLE POD RAFT SLAB PLAN


SCALE 1: 50

NOTES:
SHEET SIZE A3 PACIFIC DEVELOPMENT & CONSTRUCTION
SCALE: AS SHOWN ADDITIONS & ALTERATIONS TO RESIDENCE
ISSUED FOR CONSTRUCTION CERTIFICATE
ORIGINAL SURVEY BY 14 D'ARCY AVE, APPIN (LOT 22 DP 246207)
DO NOT SCALE DRAWINGS. USE FIGURED
N/A PROPOSED SHED
DIMENSIONS ONLY. ALL DISCREPANCIES TO BE SLAB PLAN
REPORTED TO PRASCON AUSTRALIA OFFICE. SURVEY DATE: N/A
COORDS & DATUM FILENAME: JOB NUMBER SHEET NUMBER REVISION
A ISSUED FOR CONSTRUCTION CERTIFICATE 30.11.2020 KD AH AH AH TN
REV AMENDMENT / REASON FOR ISSUE DATE DES. DWN. DWGCHK. VERIFIED APPROVED -
20236.DWG 20236 02 A
© PRASCON AUSTRALIA PTY LTD
SL82 MESH PIPE WRAPPED WITH 2N12 - 1000 LONG
10 ABLEFLEX TRIMMER

NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH
40
ARCHITECTURAL DRAWINGS AND THE SPECIFICATION.
2. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE NOTED.
PIPE WRAPPED WITH
10 ABLEFLEX
3. ALL DISCREPANCY SHALL BE REFERRED TO PRASCON AND
1:1 SLOPE
1-N12; ANY VARIATIONS SHALL BE APPROVED BY PRASCON PRIOR
400 400 40 BOTTOM COVER TO PROCEEDING WITH THE WORK.
1-N12 TO LAP; 4. ALL DIMENSIONS RELEVANT TO SETTING OUT AND
40 BOTTOM COVER 200 LAP OFF-SITE WORK SHALL BE VERIFIED ON SITE BY THE
200 LAP L11TM300 OR 3-N12 CONTRACTOR BEFORE CONSTRUCTION AND FABRICATION
TYPICAL PIPE (DIAMETER < 150 mm) ARE COMMENCED.
TYPICAL PIPE (DIAMETER < 150 mm) PENETRATION 5. PRASCON'S DRAWINGS ARE NOT TO BE SCALED. NO
THROUGH RIB BEAM DETAIL PENETRATION THROUGH GROUND SLAB DETAIL RESPONSIBILITY WILL BE TAKEN BY PRASCON FOR
(PLAN VIEW) TYPICAL FOUNDATION CORNER DETAIL DIMENSIONS OBTAINED BY SCALING THE DRAWINGS.
(ELEVATION VIEW)
SCALE 1: 25
SCALE 1: 25 (PLAN VIEW)
SCALE 1: 25

1-N12 AT RIB LOCATIONS TIMBER FRAME TO


1-N12 AT RIB LOCATIONS 40 BOTTOM COVER AS 1684

PIPE WRAPPED WITH


10 ABLEFLEX
1-N12 AT RIB LOCATIONS WAFFLE POD
N12 'L' BAR AT CORNER 1-N12 AT RIB LOCATIONS SL82 MESH;
40 BOTTOM COVER 40 BOTTOM COVER 30 TOP COVER
400

85
REFER
PLAN

REFER
PLAN
110
400 400 150 MIN.
400
L11TM200 OR 3-N12 PERIMETER; 1-N12;
1-N12 TO LAP; 40 BOTTOM COVER 40 BOTTOM COVER
40 BOTTOM COVER
300 1090 110 MIN 200 mm CONCRETE
UNDERLAY

TYPICAL WAFFLE SLAB 'T' INTERSECTION DETAIL TYPICAL EDGE & RIB BEAM DETAIL
(PLAN VIEW) TYPICAL PIPE (DIAMETER < 150 mm)
SCALE 1: 25
PENETRATION THROUGH RIB BEAM DETAIL A SECTION A
2 SCALE 1: 25
(PLAN VIEW)
SCALE 1: 25

TIMBER FRAME TO
AS 1684
15 MIN CHAMFER EDGE
TIMBER FRAME TO WAFFLE POD LOCALISED BEND
AS 1684 SL82 MESH; DOWN MESH
30 TOP COVER 15
POD EXTENSION - INSERT WAFFLE POD

85
EXTRA N12 PERIMETER;
EXTRA POD OFFCUT TO SL82 MESH;

REFER
30 TOP COVER

PLAN
INTERNAL FINISHED FLOOR LEVEL

REFER
30 TOP COVER

PLAN
MATCH LENGTH (1500 MAX) WAFFLE POD

85
1000 OR LESS
SL82 MESH;

REFER
PLAN
BEND 90o
85

1-N12; L11TM300 OR 3-N12 PERIMETER;


REFER
PLAN

200 mm CONCRETE 40 BOTTOM COVER 40 BOTTOM COVER


REFER
PLAN

EXTERNAL FINISHED LEVEL UNDERLAY


110 MIN 1090 300
1-N12;
CONTROLLED FILL
40 BOTTOM COVER
150 MIN. (REFER TO GENERAL NOTES)
1090 TYPICAL WAFFLE POD LENGTH 200 mm CONCRETE
OFF-CUT POLYSTYRENE
L11TM200 OR 3-N12 PERIMETER; OR BACKFILL
UNDERLAY TYPICAL GARAGE DOOR REBATE DETAIL
40 BOTTOM COVER
300 1500 MAX. 110 MIN
300 MIN. 1090 MAX 110 C SECTION C
2 SCALE 1: 25
TYPICAL WAFFLE POD EXTENSION DETAIL
FRAMED EXTERNAL CLAD
B DETAIL B TYPICAL DROP EDGE & RIB BEAM DETAIL
2 SCALE 1: 25
D SECTION D
2 SCALE 1: 25

NOTES:
SHEET SIZE A3 PACIFIC DEVELOPMENT & CONSTRUCTION
SCALE: AS SHOWN ADDITIONS & ALTERATIONS TO RESIDENCE
ISSUED FOR CONSTRUCTION CERTIFICATE
ORIGINAL SURVEY BY 14 D'ARCY AVE, APPIN (LOT 22 DP 246207)
DO NOT SCALE DRAWINGS. USE FIGURED
N/A PROPOSED SHED
DIMENSIONS ONLY. ALL DISCREPANCIES TO BE SLAB DETAIL
REPORTED TO PRASCON AUSTRALIA OFFICE. SURVEY DATE: N/A
COORDS & DATUM FILENAME: JOB NUMBER SHEET NUMBER REVISION
A ISSUED FOR CONSTRUCTION CERTIFICATE 30.11.2020 KD AH AH AH TN
REV AMENDMENT / REASON FOR ISSUE DATE DES. DWN. DWGCHK. VERIFIED APPROVED -
20236.DWG 20236 03 A
© PRASCON AUSTRALIA PTY LTD
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ARCHITECTURAL
DRAWINGS AND THE SPECIFICATION.
C1 C1 2. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE NOTED.
3. ALL DISCREPANCY SHALL BE REFERRED TO PRASCON AND ANY
VARIATIONS SHALL BE APPROVED BY PRASCON PRIOR TO PROCEEDING
WITH THE WORK.
4. ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL
BE VERIFIED ON SITE BY THE CONTRACTOR BEFORE CONSTRUCTION
AND FABRICATION ARE COMMENCED.
5. PRASCON'S DRAWINGS ARE NOT TO BE SCALED. NO RESPONSIBILITY
WILL BE TAKEN BY PRASCON FOR DIMENSIONS OBTAINED BY SCALING
THE DRAWINGS.
6. ALL OTHER FLOOR JOIST, WALL AND SLAB NOT SHOWN ON THE DRAWING
SHALL BE TIMBER CONSTRUCTED AS PER AS 1684.
7. ALL WELDING SHALL BE CONTINUOUS.

MEMBER SCHEDULE
8955

45
10 PLATE WITH
6 CFW TO PFC f12 HOLES FOR M10 BOLT
CONNECTION INTO C1 COLUMN

86
200PFC

B1 END SECTION

10 PLATE WITH
6 CFW TO C1 COLUMN
25
f14 HOLES FOR M12 DYNABOLT

B1
C1 C1
30 45

89 SHS 5.0
2235

C1 COLUMN BASE PLATE

2835

7125

PROPOSED FIRST FLOOR STEEL FRAMING PLAN


SCALE 1: 50

NOTES:
SHEET SIZE A3 PACIFIC DEVELOPMENT & CONSTRUCTION
SCALE: AS SHOWN ADDITIONS & ALTERATIONS TO RESIDENCE
ISSUED FOR CONSTRUCTION CERTIFICATE
ORIGINAL SURVEY BY 14 D'ARCY AVE, APPIN (LOT 22 DP 246207)
DO NOT SCALE DRAWINGS. USE FIGURED
N/A PROPOSED SHED
DIMENSIONS ONLY. ALL DISCREPANCIES TO BE FIRST FLOOR STEEL FRAMING PLAN
REPORTED TO PRASCON AUSTRALIA OFFICE. SURVEY DATE: N/A
COORDS & DATUM FILENAME: JOB NUMBER SHEET NUMBER REVISION
A ISSUED FOR CONSTRUCTION CERTIFICATE 30.11.2020 KD AH AH AH TN
REV AMENDMENT / REASON FOR ISSUE DATE DES. DWN. DWGCHK. VERIFIED APPROVED -
20236.DWG 20236 04 A
© PRASCON AUSTRALIA PTY LTD
NOTES:
1. THIS DRAWING SHALL BE READ IN CONJUNCTION WITH ARCHITECTURAL
DRAWINGS AND THE SPECIFICATION.
C1 C1 2. ALL DIMENSIONS ARE IN mm UNLESS OTHERWISE NOTED.
3. ALL DISCREPANCY SHALL BE REFERRED TO PRASCON AND ANY
VARIATIONS SHALL BE APPROVED BY PRASCON PRIOR TO PROCEEDING
WITH THE WORK.
4. ALL DIMENSIONS RELEVANT TO SETTING OUT AND OFF-SITE WORK SHALL
BE VERIFIED ON SITE BY THE CONTRACTOR BEFORE CONSTRUCTION
AND FABRICATION ARE COMMENCED.
5. PRASCON'S DRAWINGS ARE NOT TO BE SCALED. NO RESPONSIBILITY
WILL BE TAKEN BY PRASCON FOR DIMENSIONS OBTAINED BY SCALING
THE DRAWINGS.
6. ALL OTHER FLOOR JOIST, WALL AND SLAB NOT SHOWN ON THE DRAWING
SHALL BE TIMBER CONSTRUCTED AS PER AS 1684.
7. ALL WELDING SHALL BE CONTINUOUS.

MEMBER SCHEDULE

B2 B2
8955

65 x 5.0 EA WITH f10 HOLES


M8 BOLT TO EVERY ALTERNATE TIMBER RAFTER

250PFC
M12 BOLT

300
NOTCHED TIMBER RAFTER OVER PFC

100
10 TOP PLATE 6CFW ON C1

10 PLATE 6CFW ON C1
89 SHS 5.0

C1 C1
SECTION
2235

2835

7125

PROPOSED FIRST FLOOR STEEL FRAMING PLAN


SCALE 1: 50

NOTES:
SHEET SIZE A3 PACIFIC DEVELOPMENT & CONSTRUCTION
SCALE: AS SHOWN ADDITIONS & ALTERATIONS TO RESIDENCE
ISSUED FOR CONSTRUCTION CERTIFICATE
ORIGINAL SURVEY BY 14 D'ARCY AVE, APPIN (LOT 22 DP 246207)
DO NOT SCALE DRAWINGS. USE FIGURED
N/A PROPOSED SHED
DIMENSIONS ONLY. ALL DISCREPANCIES TO BE ROOF STEEL FRAMING PLAN
REPORTED TO PRASCON AUSTRALIA OFFICE. SURVEY DATE: N/A
COORDS & DATUM FILENAME: JOB NUMBER SHEET NUMBER REVISION
A ISSUED FOR CONSTRUCTION CERTIFICATE 30.11.2020 KD AH AH AH TN
REV AMENDMENT / REASON FOR ISSUE DATE DES. DWN. DWGCHK. VERIFIED APPROVED -
20236.DWG 20236 05 A
© PRASCON AUSTRALIA PTY LTD

Das könnte Ihnen auch gefallen