Sie sind auf Seite 1von 4

Atlas

Perfect floor slab insulation for every type of house.

Edge system

2nd installation row


3rd installation row

initial elemet

1st installation row


tion
talla ns
th a rea i
5

4th installation row

ion
llat
n sta
ai
are
6th

Installation Instructions
Installation instructions JACKODUR® Atlas – Edge system

JACKODUR® Atlas - Edge system

General notes
With JACKODUR® Atlas, you have chosen a time and The innovative plug-in system systematically excludes
money-saving floor slab insulation system suitable for thermal bridges and the insulation meets all current energy
different layouts. JACKODUR® Atlas comprises various standards. The JACKODUR® Atlas system is made of
elements which can be combined individually. extruded polystyrene foam (XPS) according to EN 13164.

JACKODUR® Atlas elements:

Corner element Side element Area element Formwork element

You receive an installation plan that shows where to position The packing list provided shows you which pallet contains
the tailor-made edge elements (special elements). the special elements.

Allgemeines
Der Aufbau und die Art des Unterbaues und Planum ist gemäß
Bodengutachten/Statischer Berechnung bzw. nach Vorgabe der Bauleitung JACKODUR® Atlas
Objekt: Obj_3674
herzustellen. Der Untergrund für die Verlegung der JACKODUR Atlas Elemente

2. installation
2nd Verlegereiherow ist eben, abgezogen herzustellen. Der JACKODUR Atlas Verlegeplan ist mit
den Ausführungsplänen des Bauvorhabens auf Übereinstimmung zu prüfen.
Die fachgerechte Verlegung des JACKODUR Atlas Systems obliegt der
ausführenden Baufirma bzw. Bauleitung. Auftragsnummer: A400259181
Verlegung
Packliste:
inogn
ut
lellga
Nach dem Verlegen des Startelementes werden die Seitenelemente bis zum
3rd installation row

nächsten Eckelement verlegt (1. Verlegereihe). Hiernach erfolgt die Verlegung

etra
weiterer Seitenelemente bis zum dritten Eckelement (2. Verlegereihe). Die

ninvs Palette 01 1 Stck. Seitenelement


Schalungselemente werden in die dafür vorgesehene Nut gesteckt und

e
eha
nachfolgend werden die Flächenelemente verlegt (3. Flächenverlegung).

aärc (38) 2 Stck. Sonderelement Nr.1


55.t
hFl Detail
2 Stck. Sonderelement Nr.3
4 Stck. Sonderelement Nr.2
Druckfestigkeit Schalungselement: 300 kPa
Druckfestigkeit Dämmung unter Bodenplatte: 300 kPa bzw.
130 kPa (50 Jahre, Stauchung <2%)

19 Stck. Sonderelement Nr.5


2 Stck. Sonderelement Nr.4
1 Stck. Sonderelement Nr.6
7 Stck. Sonderelement Nr.7
Hinweis: Auf der Wärmedämmung ist eine
row

Trennlage (z.B. PE-Folie) anzuordnen


Verlegereihe

Palette 02 13 Stck. Flächenelement


1st1.installation

Legende
(40) 27 Stck. Seitenelement
initial elemet
Startelement
Eckelement Seitenelement Flächenelement Schalungselement

blaue Bemaßung = Betonaussenkante


4th installation row Palette 03 36 Stck. Schalungselement
JACKON Insulation GmbH
Carl-Benz-Str. 8
D-33803 Steinhagen
1 Stck. Perimeterkleber

Fon: +49-5204-9955-0
Fax: +49-5204-9955-400
www.jackon-insulation.com
Stufenfalz-Richtung
beachten
JACKODUR Atlas
Wärmedämm- und Schalungssystem für Bodenplatten
Bauvorhaben Objekt Nr.
Hubert
D_3675

Datum Maßstab Einheit Gezeichnet


09.06.2017 nicht maßstäblich mm MPa.

1. Preparation of the site and setting out


It is fundamental to avoid any risk of frost below the
foundation. That is why the hardcore has to comply with the
requirements of the planner/structural engineer. Typically
the hardcore is made of crushed stone, granular and is
non-frost susceptible (good draining). If the hardcore is frost
susceptible or if the maximal local depth of frost penetration
is not reached then a frost insulation (ISO13793) has to be
installed. Crushed stone 2/5 or 4/8 is an ideal material for a
leveling filler layer on the top of hardcore. For the substrate,
a tolerance of +/- 1 cm over 5 m is
recommended for a precision fit insulation arrangement.
The blinding layer should be applied about 40 cm wider
than the outer edge of the floor slab. If possible, the batter
board should be erected at a distance of about 80 cm from
the outer edge of the floor slab. For further preparation, the
layout lines are stretched over the outer edge of the floor
slab (without thermal insulation).
Installation instructions JACKODUR® Atlas – Edge system

2. Begin with the initial element


The installation plan shows which corner to begin the
installation. The initial element must be installed as shown
in the plan (note direction of stepped profile!). With the aid
of the erected batter board arrangement, use the tensioned
layout line to arrange the initial element (outer edge of the
floor slab). Then install the side elements in the direction
“1st installation row” and thereafter continue the installation
in the direction “2nd installation row” until the edge is
complete.

3. Formwork elements
Subsequently, insert the formwork elements progressively
into the groove of the side elements with joints offset till
the next corner element is reached. The formwork elements
must be cut to length (e.g. with a handsaw or a hot wire
cutter).

2nd insta
llation ro
ow w
io nr
lat
tal
ins
3rd

n
llatio 4. Area elements
insta
area
The area elements can now be installed proceeding from
one corner with tight joints in any bonding pattern. Cut the
last area element in any row to size up to the adjoining side
row

element.
ion
lat
tal
ins
t
1s

4th
inst
alla
tion
row
Installation instructions JACKODUR® Atlas – Edge system

5. Penetrations (e.g. for drainage lines, conduits, ventilation


ducts) must be notched to size on site, e.g. with a handsaw
or portable jigsaw. Use JACKODUR® Perimeter Adhesive
(λ 0.0354) to seal off penetrations and open joints in the
insulation layer.

JACKODUR® and JACKOBOARD® are registered trademarks of JACKON Insulation GmbH. Subject to errors and changes. Part no. 4515913 EN 06/2020
6. After installation
Subsequently, install a separation layer, e.g. PE film, over
the thermal insulation boards. Install it loose and with
overlapping, taped joints.

Note
The information in this publication represents our current state of knowledge and experience. They do not
represent any guarantee in the legal sense of the term. When using these products, the specific conditions
relative to the particular application must always be taken into account, especially with regard to structural

Application film physics, civil engineering and statutory building regulations.


JACKODUR® Atlas

JACKON Insulation GmbH | Carl-Benz-Strasse 8 | D-33803 Steinhagen, Germany


Phone +49 (0) 5204 9955-499 | Fax +49 (0) 5204 9955-400 | atlas@jackodur.com | www.jackon-insulation.com

Das könnte Ihnen auch gefallen