HIGH BAY
Acrylume Acrylic..........................................................402, 410
Hi-Tek Aluminum ..................................403-405, 407, 411-413
Contractor Select Stock ........................................................406
DuraBay Glass...................................................... 408-409, 414
LOW BAY
Acrylume Acrylic.......................................... 415-416, 421, 425
Hi-Tek Aluminum ..........................................417-419, 422-424
Contractor Select Stock ........................................................420
CONTROL SYSTEMS
Multi-Level Lighting..................................................... 428-430
401
PRODUCT INFORMATION Acrylume Acrylic
HIGH BAY
Intended Use reflector yields high vertical probe start shipments outside Optical mounting: Adjustable
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TH 400MP PA22 TB SCWA
Series Lamp type8 Reflector8 Voltage Ballast Options
TH Protected metal halide 450MP PA22 TB 7
Pulse start metal halide For options and accessories,
see pages 433-439.
175MP 875MP PA22N 120 For shipments to U.S. territories, SCWA must be specified to comply with EISA.
200MP 1000MP PA22L1 2083,4 SCWA Super constant wattage autotransformer
250MP High pressure sodium PA22E2 2403,4,5 RLB Regulated lag ballast (175-400W)
320MP 250S PA25 277 Non EISA ballast
350MP 400S 347 (blank) Standard magnetic ballast6,9
400MP 1000S 4803,4 SCWI Isolated SCWA (400W)6,10
CWI Constant wattage isolated6,9
MRB Magnetic regulator ballast
CONFIGURATIONS Drawings are for dimensional detail only and may not represent actual
REFLECTOR LAMP TYPE mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
PA22, PA22N, PA22E, 175MP, 200MP, 250MP, 320MP, 350MP,
PA22L 400MP, 450MP, 250S, 400S
PA25 875MP, 1000MP, 1000S 24-1/4 to 27-1/4 23-1/8 to 26-1/8
(61.6 to 69.2) (58.7 to 66.4)
13-1/2 14-1/4
(34.3) (36.2) Notes
1 Lensed bottom, open top. Periodic cleaning maintains
22-3/8 performance. Does not meet UL lamp rupture containment.
(56.8) 25-7/8 2 Enclosed bottom, open top. Meets UL lamp rupture
(65.7) containment standards Periodic cleaning maintains
TH PA22
LITHONIA INDOOR HID
TH PA25 performance.
3 Requires CWI or RLB option in Canada for metal halide.
Available in 175-400W.
4 Requires CWI or MRB option in Canada for high pressure
sodium. Available 70-400W.
5 220V and 240V, 50Hz and 60Hz ballasts available for use
with U.S. protected metal halide lamps.
6 Available for shipments outside of U.S. only.
7 Optional multi-tap ballast (12OV, 208V, 247V, 277V; 120V,
277V, 347V in Canada.)
8 Specify lamp type and reflector; see Configurations table.
9 175-450W metal halide only.
10 400W metal halide only.
HIGH BAY
Intended Use Self-cleaning, ventilated protected metal halide Listings
For high mounting heights
that require high efficiencies,
design carries optical con-
taminants out through open
lamps only. A17: UL Listed -30°C to 55°C
ambient operations and TH A17
TH A22
horizontal illumination and top of reflector. Installation damp locations. High
premium glare control. Ideal Pendant splice box threaded ambient (HA) option of
for manufacturing areas Electrical for 3/4" conduit (standard). 65°C available.
and aisles. Ballast: All ballasts are 100%
factory tested. HPS: Constant
Pendant splice box, remov-
able cast-aluminum box A22: UL Listed -30°C to
Hi-Tek®
Construction wattage autotransformer. slides on integral die-cast 55°C ambient operations
Housing: Rugged, heavy- MH: 175-450W fixtures aluminum housing mount- and damp locations. High
duty, die-cast aluminum shipped within the U.S. ing flange and mounts ambient (HA) option of 65°C
with white polyester powder require super CWA pulse to 3/4" pendant conduit available. 875W and 1000W
finish. Electrical components start ballasts which are 88% prior to ballast housing pulse start -30°C to 40°C.
horizontally opposed and efficient and EISA-legislation installation. Matching wire
heat-sinked to ballast hous- compliant (must specify access cover accepts RELOC® All are UL Listed to U.S. and
ing for cool operation. SCWA option). CSA, NOM or modular wiring. Complete Canadian safety standards.
INTL options required for assembly meets or exceeds NOM Certified.
Optics probe start shipments outside UL50-pound pull test. Other
Premium-spun aluminum, the U.S. 1000W is constant mounting options available.
anodized reflector combines wattage autotransformer.
high efficiency with extended Optical mounting: Adjust-
TH A17
shielding angles for high Socket: Vertically oriented able reflector mounting
performance. Exclusive fluted mogul base protected exclu- brackets are progressively
design minimizes arc tube sionary "PINK" socket with die-formed of 18-gauge
voltage rise. Optical system copper alloy, nickel-plated galvanized steel.
is adjustable and accom- screw shell and center con- TH A22
modates the full range of tact. For use with O-rated,
industrial light distributions.
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TH 400MP A17 TB SCWA
Series Lamp type6 Reflector6 Voltage Ballast Options
4
TH Protected metal halide High pressure sodium A17 TB Pulse start metal halide For options and accessories,
175MP 70S A22 120 For shipments to U.S. territories, SCWA must be specified to comply with EISA. see pages 433-439.
200MP 100S 2081,2 SCWA Super constant wattage autotransformer
250MP 150S 2401,2,3 RLB Regulates lag ballast
320MP 200S 277 Non-EISA ballast
350MP 250S 347 (blank) Standard magnetic ballast5,7
400MP 400S 4801,2 SCWI Isolated SCWA5,8
450MP 1000S CWI Constant wattage isolated5,7
875MP MRB Magnetic regulator ballast
1000MP
CONFIGURATIONS Drawings are for dimensional detail only and may not represent actual
REFLECTOR LAMP TYPE mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
175MP, 200MP, 250MP, 320MP, 350MP, 400MP, 450MP,
A17 70S, 100S, 150S, 200S, 250S, 400S 21-5/8 to 24-5/8 21-5/8 to 24-5/8
A22 875MP, 1000MP, 100S, 150S, 200S, 250S, 400S, 1000S (55.0 to 62.5) (55.0 to 62.5)
12-1/8 12-1/4
(30.8) (31.1)
17-7/8 23-1/4
LITHONIA INDOOR HID
(45.4) (59.1)
TH A17 TH A22
Notes
1 Requires CWI or RLB option in Canada for metal halide. Available in 175-400W.
2 Requires CWI or MRB option in Canada for metal halide. Available in 70-400W.
3 220V and 240V, 50Hz and 60Hz ballasts available for use with U.S. protected metal halide lamps.
4 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada.)
5 Available for shipments outside of U.S. only.
6 Specify lamp type and reflector; see Configurations table.
7 175-450W metal halide only.
8 400W metal halide only.
Intended Use voltage rise for optimal Socket: Vertically oriented die-formed of 18-gauge
TH A16GL and horizontal illumination. ventilated design that carries copper alloy, nickel-plated Listings
Ideal for general manufactur- contaminants out through screw shell and center con- THD: UL Listed -30°C to 55°C
ing areas, storage areas and top of reflector. Lensed tact. For use with O-rated, ambient operations and
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TH 400MP A16 TB SCWA
Series Lamp type Reflector Voltage Ballast Options
6
TH Protected metal halide High pressure sodium A16 TB Pulse start metal halide For options and accessories,
THD1 200MP 70S A16GL2 120 For shipments to U.S. territories, SCWA must be specified to comply see pages 433-439.
250MP 100S 2083,4 with EISA.
320MP 150S 2403,4,5 SCWA Super constant wattage autotransformer
350MP 200S 277 RLB Regulated lag ballast
400MP 250S 347 Non-EISA ballast
400S 4803,4 (blank) Standard magnetic ballast7,8
SCWI Isolated SCWA7,9
CWI Constant wattage isolated7,8
MRB Magnetic regulator ballast
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
Notes
1 THD consists of TH housing and A16 reflector shipped in one carton. Available
LITHONIA INDOOR HID
HIGH BAY
Intended Use A14: One piece hydroformed, Socket: Vertically oriented Listings
Use in high mounting heights
that require high efficiencies,
anodized aluminum reflec-
tor provides rectangular
mogul base protected exclu-
sionary "PINK" socket with
UL Listed -30°C to 55°C ambi-
ent operations and damp TH A14
horizontal illumination and
high vertical illumination.
Ideal for manufacturing and
distribution for maximum
luminaire spacing and verti-
cal illumination.
copper alloy, nickel-plated
screw shell and center contact.
locations. High ambient (HA
option) of 65°C available.
(HA not available on THD
TH A15
warehouse aisles where color
is critical.
A15: High-efficiency,
anodized, spun aluminum
Installation
Pendant splice box: Remov-
A15). UL Listed to U.S. and
Canadian safety standards. THD A15
Construction
reflector features exclusive
contoured design.
able cast-aluminum box
slides on integral die-cast
NOM Certified. Hi-Tek®
Housing: Rugged, heavy- aluminum housing mounting
duty, die-cast aluminum Electrical flange and mounts to 3/4"
with white polyester powder Ballast: All ballasts are 100% pendant conduit prior to
finish. Electrical components factory tested. HPS: Constant ballast housing installation.
horizontally opposed and wattage autotransformer. Matching wire access cover
heat-sinked to ballast housing MH: 175-450W fixtures accepts RELOC® modular
for cooler operation. Integral shipped within the U.S. wiring. Complete assembly
splice box mounting flange require super CWA pulse meets or exceeds UL 50-
ensures structural integrity. start ballasts which are 88% pound pull test.
efficient and EISA-legislation
Optics compliant (must specify Optic mounting adjustable
Self- cleaning ventilated SCWA option). CSA, NOM reflector mounting brackets TH A14
design carries contaminants or INTL options required are progressively die-formed
through the top of the for probe start shipments of 18-gauge galvanized steel.
reflector. outside the U.S.
TH A15 / THD A15
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TH 400MP A15 TB SCWA
Series Lamp type Reflector Voltage Ballast Options
5
TH Protected metal halide High pressure sodium A14 TB Pulse start metal halide For options and accessories,
THD1 175MP 70S A15 120 For shipments to U.S. terrirtories, SCWA must be specified to comply with EISA. see pages 433-439.
200MP 100S 2082,3 SCWA Super constant wattage autotransformer
250MP 150S 2402,3,4 RLB Regulated lag ballast
320MP 200S 277 Non-EISA ballast
350MP 250S 347 (blank) Standard magnetic ballast6,7
400MP 400S 4802,3 CWI Constant wattage isolated6,7
450MP MRB Magnetic regulator ballast
SCWI Isolated SCWA6,8
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
8-1/8
(20.6) Notes
LITHONIA INDOOR HID
1 THD consists of TH housing and A15 reflector shipped in a carton.
8-1/4
(30.8) Available with 400MP tapped ballast only. SCWA only.
13-5/8 2 Requires CWI or RLB option in Canada for metal halide. Available for
(34.6) 175-450W only.
TH A14 14-1/8 3 Requires CSI or MRB option in Canada for high pressure sodium.
(35.9) Available for 70-400W only.
TH A15 / THD A15 4 220V and 240V 50Hz and 60Hz ballasts available for use with U.S. protected
metal halide and high pressure sodium lamps.
5 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in
Canada).
6 Available for shipments outside of U.S. only.
7 175-450W metal halide only.
8 400W metal halide only.
CTL
ORDERING INFORMATION
COMPONENT DESCRIPTION 1
PARTS
CHCX400PPS HSG Housing with 400W protected socket, pendant splice box, steel hook and reflector legs. Works with either CHD or CXD optical.
A15 15 inch spun aluminum reflector.
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
22-1/8
(56.2) 24-1/4
(61.6)
LITHONIA INDOOR HID
14-1/8
(35.9)
9-7/8
CHD (25.1)
CTL
Notes
1 Canadian products ship with standard probe start ballast.
HIGH BAY
Intended Use angle for high-performance Socket: Vertically oriented socket. Optic is sealed at the
For high-mounting heights
that require high efficiencies,
optical control. Exclusive
fluting design minimizes arc
mogul base socket with cop-
per alloy, nickel-plated screw
point of attachments with a
one-piece gasket of FDA -ap- TE E17
horizontal illumination,
premium glare control and
total enclosure. Ideal for
tube voltage rise. Gasketed,
clear, tempered-glass lens
inhibits the entrance of ambi-
shell and center contact. UL
Listed 1500W, 600V, 5KV
pulse rated for U.S. lamps.
proved material. A 16-gauge
galvanized steel support ring
with matching keyhole slots
TE E22
heavy manufacturing areas, ent contaminants. Hinge is pre-installed for vibration- Hi-Tek®
gymnasiums and wet loca- and lens retainer latches for Installation resistant mounting.
tion applications (Must be tool-less access. Pendant splice box-
ordered with WL option). removable cast-aluminum Listings
Electrical box slides on integral UL Listed to U.S. and Cana-
Construction Ballast: All ballasts are 100% die-cast aluminum housing dian safety standards. NOM
Housing: Rugged, heavy- factory tested. HPS: Constant mounting flange and mounts Certified. UL Listed for damp
duty, die-cast aluminum wattage autotransformer. to 3/4" pendant conduit locations. Ambient operation:
with white polyester powder MH: 175-400W fixtures prior to ballast housing -30°C to 55°C (high ambient
finish. Electrical components shipped within the U.S. installation. Matching wire HA option for 65°C). 750W,
are horizontally opposed and require super CWA pulse access cover accepts RELOC® 875W and 1000W pulse-start
heat-sinked to ballast hous- start ballasts which are 88% modular wiring. Complete -30° C to 40° C.
ing for cool operation. efficient and EISA-legislation assembly meets or exceeds
compliant (must specify UL 50-pound pull test.
Optics SCWA option). CSA, NOM or TE E17
One-piece, totally INTL options required for Optical mounting: four
enclosed-and-gasketed spun probe start shipments outside 8-32 corrosion-resistant,
aluminum, anodized reflector the U.S. 1000W is constant tri-lobular, thread-rolling
combines high efficiency wattage autotransformer. screws are arranged con-
with extended shielding centrically around the lamp
TE E22
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TE 400M E17 M TB SCWA
6 6 6
Series Lamp type Reflector Distribution Voltage
TE Metal halide 400M High pressure sodium E17 N Narrow TB4
175M 750M 70S E22 C Concentrated 120
200M 875M 100S M Medium 2081,2
250M 1000M 150S S Spread 2401,2,3
320M 200S W Wide 277
350M 400S 347
4801,2
Ballast Options
Pulse start metal halide For options and accessories, see pages 433-439.
For shipments to U.S. territories, SCWA must be specified to comply with EISA.
SCWA Super constant wattage autotransformer
RLB Regulated lag ballast
Non-EISA compliant
(blank) Standard magnetic ballast 5,7
CWI Constant wattage isolated 5,7
SCWI Isolated SCWA 5,8
MRB Magnetic regulator ballast
CONFIGURATIONS Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters) Notes
LITHONIA INDOOR HID
REFLECTOR LAMP TYPE DISTRIBUTION unless otherwise noted. 1 Requires CWI or RLB option in Canada for metal halide. Available for
70S, 100S, 150S, 200S,
E17 C, M, S, W 175-450W only.
175M, 200M, 250M
24-3/8 24-3/8 2 Requires CWI or MRB option in Canada for high pressure sodium.
E17 320M, 350M, 400M, 400S M, S, W Available for 70-400W only.
(61.9) (61.9)
E22 350M, 400M, 750M, 875M, 400S N, C 3 220V and 240V 50Hz and 60Hz ballasts available for use with U.S,
E22 1000M C, M, S protected metal halide and high pressure sodium lamps.
17-3/8 17-3/8 4 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V
(44.1) (44.1) in Canada).
5 Available for shipments outside of U.S. only.
17-7/8 23 6 Specify lamp type and reflector; see Configurations table.
(45.4) (58.4) 7 175-400W metal halide only.
TE E17 TE E22 8 400W metal halide only.
TPG PG21A horizontal and vertical heat-resistant borosilicate wattage autotransformer. Installation
illumination, and premium glass reflector mounted MH: 175-450W fixtures Installation: Cast-aluminum
contrast control. Optimum within heavy-gauge rigid shipped within the U.S. pendant splice box threaded for
TPG PG21
TPG PG16
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TPG 400MP PG16 M TB SCWA
6 6 6
Series Lamp type Reflector Distribution Voltage
TPG Protected metal halide 875MP PG16 N Narrow TB3
175MP 1000MP PG21 C Concentrating 120
200MP High pressure sodium PG16A M Medium 2081,2
250MP 150S PG21A S Spread 2401,2
320MP 200S W Widespread 277
350MP 250S N21 Narrow 3475
400MP 400S C21 Concentrating 4801,2
450MP 1000S M21 Medium (1000S only) TBV4
Ballast Options
Pulse start metal halide Non-EISA ballast For options and accessories, see pages 433-439.
For shipments to U.S. territories, SCWA must be specified to comply with EISA. (blank) Standard magnetic ballast5,7
SCWA Super constant wattage autotransformer CWI Constant wattage isolated5,7
RLB Regulated lag ballast MRB Magnetic regulator ballast
SCWI Isolated SCWA5,8
CONFIGURATIONS Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
REFLECTOR LAMP TYPE DISTRIBUTION unless otherwise noted.
175MP, 200MP, 250MP, 320MP, 400MP,
PG16 N, C, M, S, W
450MP, 150S
PG16 200S, 250S, 400S C, M, S, W 26 28
PG16A 150S N, C, M, S, W (66.0) (71.1) Notes
175MP, 200MP, 250MP 320MP, 350MP, 1 Requires CWI or RLB option in Canada for metal halide. Available for
PG16A C, M, S, W
LITHONIA INDOOR HID
HIGH BAY
Intended Use design carries optical con- Electrical Installation
For high mounting heights
that require high efficiencies,
taminants out through top
of reflector. High-efficiency,
Ballast: All ballasts are 100%
factory tested. HPS: Constant
Installlation: Cast-aluminum
pendant splice box threaded for TPGE PG16GLE
horizontal illumination and
premium contrast control.
Optimum performance for
high-performance, heat-
resistant borosilicate glass
reflector mounted within
wattage autotransformer.
MH: 175-450W fixtures
shipped within the U.S.
3/4" conduit (standard). Other
mounting options available. TPGE PG21GLE
high ambient temperatures
and harsh environments.
heavy-gauge rigid wire form
rings and rods fitted to top
require super CWA pulse
start ballasts which are 88%
Listings
UL Listed to U.S. and TPGE PG16AGLE
Ideal for heavy manufactur-
ing areas, warehouses, retail
aisles and gymnasiums.
and bottom of reflector.
Yields high vertical footcan-
dles with low brightness and
efficient and EISA-legislation
compliant (must specify
SCWA option). CSA, NOM or
Canadian safety standards.
NOM Certified. UL Listed for
damp locations. Ambient TPGE PG21AGLE
Construction
excellent contrast control. INTL options required for operation: -30°C to 55°C (high
ambient HA option for 65°C).
DuraBay®
probe start shipments outside
Housing: Rugged, heavy-duty, PGE16AGLE and PGE21AGLE: the U.S. 1000W is constant 750W, 875W and 1000W
die-cast aluminum with white High-efficiency, high- wattage autotransformer. pulse start -30°C to 40°C.
polyester powder finish. Elec- performance, heat-resistant
trical components horizon- borosilicate glass reflector Socket: Glazed porcelain,
tally opposed and heat-sinked with aluminum shroud to vertically oriented, mogul
to ballast housing. protect glass prisms from oily base socket with copper
dirt accumulation, emphasiz- alloy, nickel-plated screw
Optics ing downward efficiency. shell and center contact. TPGE PG21AGLE TPGE PG16AGLE
PGE16GLE and PGE21GLE:
Self-cleaning, ventilated
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TPGE 400M PG16GLE M TB SCWA
Series Lamp type6 Reflector6 Distribution6 Voltage
TPGE Metal halide 750M 400S PG16GLE N Narrow TB3
175M 875M 1000S PG21GLE C Concentrating 120
250M 1000M PG16AGLE M Medium 2081,2
320M High pressure sodium PG21AGLE S Spread 2401,2
350M 150S W Widespread 277
400M 200S N21 Narrow 347
450M 250S C21 Concentrating 480
TBV4
Ballast Options
Pulse start metal halide Non-EISA ballast For options and accessories, see pages 433-439.
For shipments to U.S. territories, SCWA must be specified to comply with EISA. (blank) Standard magnetic ballast5,7
SCWA Super constant wattage autotransformer CWI Constant wattage isolated5,7
RLB Regulated lag ballast MRB Magnetic regulator ballast
SCWI Isolated SCWA5,8
CONFIGURATIONS Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
REFLECTOR LAMP TYPE DISTRIBUTION unless otherwise noted.
150S, 175M, 250M, 320M, 350M, Notes
PG16GLE, PG16AGLE N, C, M, S, W
400M, 450M 1 Requires CWI or RLB option in Canada for metal halide. Available
PG16GLE, PG16AGLE 200S, 250S, 400S C, M, S, W 26-1/8 for 175-450W only.
28-1/2
PG21GLE, PG21AGLE 350M, 400M, 450M, 750M, 875M N21 (66.4) (72.4) 2 Requires CWI or MRB option in Canada for high pressure sodium.
LITHONIA INDOOR HID
PG21GLE, PG21AGLE 1000M, 400S, 1000S C21 Available for 70-400W only, 200V and 240V, 50Hz and 60Hz ballast
available for use with U.S. metal halide and high pressure sodium
17-5/8 lamps.
20-1/2
(44.7) (52.1) 3 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V,
347V in Canada).
4 Optional SCWA five-tap ballast (120V, 208V, 240V, 277V, 480V).
17-1/4 Available for 250W, 400W, 1000W metal halide and high pressure
(44.3) 22-1/2
(57.2) sodium (CWA only).
TPG PG16GLE 5 Available for shipments outside of U.S. only.
TPG PG21GLE
6 Specify lamp type, reflector and distribution; see Configurations
table.
7 175-450W metal halide only.
8 400W metal halide only.
Intended Use finish. All electrical compo- Electrical splice box with top entry for
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: SH 400MP PA22 TVOLT HEB
Series Lamp type Reflector Voltage Ballast Options
1
SH Protected metal halide PA22 TVOLT Pulse start metal halide For options and accessories, see pages 433-439.
320MP PA22N 120 HEB HID electronic ballast
350MP PA22L 208
400MP PA25 240
277
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
13-1/2
(34.3) 14-1/4
(36.2)
22-3/8
(56.8) 25-7/8
(65.7)
SH PA22 SH PA25
LITHONIA INDOOR HID
Notes
1 Tri-volt electronic ballast capable of operating on any line voltage between
120V and 277V at 50Hz or 60Hz. Operates 320, 350 and 400W pulse
start lamp only.
HIGH BAY
Intended Use Optics Ballast will operate pulse Listings
For high mounting heights
that require higher efficien-
Optics: Premium spun alumi-
num anodized reflector com-
start lamps only from 120V –
277V. 50/60Hz.
UL Listed to U.S. and Cana-
dian safety standards. NOM SH A17
cies, high horizontal and
vertical illumination and pre-
mium contrast control. Ideal
bines high efficiency with
extended lamp shielding and
glare control. Exclusive fluted
Socket: Vertically
oriented mogul base pro-
Certified. UL Listed for damp
locations. Ambient operation:
-30°C to 40°C
SH A22
for light manufacturing areas, design that minimizes color tected exclusionary "PINK"
socket with copper alloy,
Hi-Tek®
warehouse and retail aisles. shift. Self-cleaning ventilated
Steel ballast housings should design carries contaminants nickel-plated screw shell and
be used in areas with minimal out of the top of the reflector. center contact. For use with
airborne contaminants. Optical system is adjustable O-rated protected metal
and accommodates the full halide lamps only.
Construction range of light distributions.
Housing: Steel housing with Installation
white polyester powder coat Electrical Installation: One-piece
finish. All electrical compo- Ballast: Pulse start, 100% galvanized hook and spring
nents are positioned to assure factory tested high power steel latch with cord and plug
unit will hang straight. Hous- factor. Meets and exceeds (SC3P) standard. Pendant
SH A17
ing is ventilated for optimal the minimum energy splice box with top entry for
thermal performance. efficiency required by the 3/4" conduit also available
Energy Indepenence and with other mounting options.
Security Act of 2007 (EISA).
SH A22
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: SH 400MP A17 277 TVOLT HEB
Series Wattage Optical Voltage Ballast Options
1 1
SH Protected metal halide A17 TVOLT Pulse start metal halide For options and accessories, see pages 433-439.
320MP A22 120 HEB HID electronic ballast
350MP 208
400MP 240
277
ACCESSORIES Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
SCK 60" safety chain kit unless otherwise noted.
WGA22 Wireguard for use with A22 reflector
WGA17 Wireguard for use with A17 reflector
23-1/4 23-1/4
(59.1) (59.1)
12-1/8 12-1/4
(31.8) (31.1)
17-7/8 23-1/4
(45.4) (59.1)
SH A17 SH A22
Notes
1 Tri-volt electronic ballast capable of operating on any line voltage between
120V and 277V at 50Hz or 60Hz. Operates 320, 350 and 400W pulse start
lamp only.
SH A16
Intended Use Optics of 2007 (EISA). Ballast will Optical mounting: Die-
Use in high mounting heights High-efficiency, anodized, operate pulse start lamps formed 18-gauge galvanized
that require high efficiencies, spun aluminum reflector with only from 200V - 277V at adjustable steel bracket.
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: SH 400MP A16 TVOLT HEB
Series Lamp type Reflector Voltage Ballast Options
SH Protected metal halide A16 TVOLT1 Pulse start metal halide For options and accessories, see pages 433-439.
320MP A16GL 120 HEB HID electronic ballast
350MP 208
400MP 240
277
ACCESSORIES Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
SCK 60" safety chain kit unless otherwise noted.
WGA16 Wireguard for use with A16 reflector
9-5/8 10-1/4
(24.4) (26.0)
16-3/8 17-3/4
(41.6) (45.1)
SH A16 SH A16GL
LITHONIA INDOOR HID
Notes
1 Tri-volt electronic ballast capable of operating on any line voltage
between 120V and 277V at 50Hz or 60Hz. Operates 320, 350 and 400W
pulse start lamps only.
HIGH BAY
Intended Use positioned to assure unit will ciency required by the Energy Optical mounting: Die-formed
For high mounting heights
that require high efficiencies
hang straight. Independence and Security
Act of 2007 (EISA). Ballast
18-gauge galvanized adjustable
steel bracket. SH A15
SH A14
and horizontal illumination. Optics will operate pulse start lamps
Ideal for general manufactur- A15: High-efficiency, only from 200V-277V at 50Hz Listings
ing areas, storage areas and anodized, spun aluminum or 60Hz. UL Listed to U.S. and
warehouse aisles. Steel bal- reflector that minimizes arc-
tube voltage rise for optimal Socket: Vertically oriented
Canadian safety standards.
NOM Certified. UL Listed for
Hi-Tek®
last housing (SH) should be
used in areas with minimal lamp life. Self-cleaning mogul base protected exclu- damp locations. Ambient
airborne contaminants. ventilated design carries sionary "PINK" socket with operation: -30°C to 40°.
contaminants out through copper alloy, nickel-plated Specify high ambient (HA
Construction top of reflectors. screw shell and center con- option) for 55°C.
Housing: Rugged octagonal tact. For use with O-rated,
steel housing provides A14: One-piece hydroformed, protected metal halide
structural strength and anodized aluminum reflector lamps only.
pleasing aesthetics. provides rectangular distribu-
Center-mounted ballast is tion for maximum luminaire Installation
heat-sinked and all electrical spacing and high illumination. Housing: Integral rapid-latch
components are positioned steel hook provided with
Electrical RELOC® or cord-and-plug
within the vented housing Ballast: Pulse start, 100% SH A15
for cooler operations. White assembly. Optional pendant
factory tested high power splice box (PSB) for 3/4"
polyester powder coat finish. factor. Meets and exceeds
All electrical components are conduit also available with
the minimum energy effi- mounting options. SH A14
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: SH 400MP A15 TVOLT HEB
Series Lamp type Reflector Voltage Ballast Options
SH Protected metal halide A15 TVOLT1 Pulse start metal halide For options and accessories, see pages 433-439.
320MP A14 120 HEB HID electronic ballast
350MP 208
400MP 240
277
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
8-1/4 8-1/8
(20.1) (20.6)
14-1/8 13-5/8
(35.8) (34.6)
SH A15 SH A14
Notes
1 Tri-volt electronic ballast capable of operating on any line voltage
between 120V and 277V at 50Hz or 60Hz. Operates 320, 350 and
400W pulse start lamps only.
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: SPG 400MP PG15 M TVOLT HEB
Series Lamp type Reflector Distribution Voltage Ballast Options
1
SPG Metal halide protected PG16 N Narrow TVOLT Pulse start metal halide For options and accessories, see pages 433-439.
320MP PG16A C Concentrating 120 HEB HID electronic ballast
350MP M Medium 208
400MP S Spread 240
W Widespread 277
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
25-1/2
(64.8)
10-1/2
(26.7)
17-1/4
(43.8)
LITHONIA INDOOR HID
Notes
1 Tri-volt electronic ballast capable of operating on any line voltage
between 120V and 277V at 50Hz or 60Hz. Operates 320, 350 and 400W
pulse start lamps only.
LOW BAY
Intended Use Optics compliant (must specify modular wiring. Complete
For controlled environments
that require a balance
Injection-molded, virgin
acrylic reflector and drop
SCWA option). CSA, NOM
or INTL options required
assembly meets or exceeds
UL 50-pound pull test. TX PA22C
between high vertical and
horizontal illumination.
Ideal for retail areas, light
(PA25D) or conical (PA22C)
lens. UV stabilized. Hinge and
lens retainer latches facilitate
for probe start shipments
outside the U.S. Optic mounting: Four 8-32
zinc-plated, tri lobular, TX PA25D
manufacturing areas and tool-less removal for main- Socket: Vertically oriented
mogul base protected exclu-
threaded-rolling screws
are arranged concentri-
Acrylume®
aisles. Certain airborne tenance and cleaning. Totally
contaminants can dimin- enclosed, gasketed refractor sionary "PINK" socket with cally around the lamp socket.
ish integrity of acrylic. and reflector inhibit the en- copper alloy, nickel-plated 16-gauge, die-formed steel
Refer to Acrylic Environ- trance of ambient contami- screw shell and center con- plate with matching keyhole
mental Compatibility nants. Meets UL lamp rupture tact. For use with O-rated, slot pattern for vibration-
tables on pages 794-795 containment specifications. protected metal halide resistant mounting. For
for suitable uses. Coated lamps provide lamps only. areas where reflectors
optimum performance. are subject to impact
Construction Installation (gymnasiums, etc.) add
Housing: Rugged, heavy- Electrical Pendant splice box 16-gauge FWG (full wireguard) to
duty, die-cast aluminum Ballast: All ballasts are 100% galvanized steel with catalog number.
with white polyester powder factory tested. HPS: Constant polyester powder finish. TX PA25D
finish. Electrical components wattage autotransformer. Removable box slides on Listings
horizontally opposed and MH: 175-450W fixtures integral die-cast aluminum UL Listed to U.S. and
heat-sinked to ballast hous- shipped within the U.S. housing mounting flange and Canadian safety standards.
ing for cooler operation. require super CWA pulse mounts to 3/4" pendant con- NOM Certified. UL Listed for
start ballasts which are 88% duit prior to ballast housing damp locations. -30°C to 40°C TX PA22C
efficient and EISA-legislation installation. Matching wire ambient operations. UL wet
access cover accepts RELOC® location available.
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TX 400MP PA22C TB SCWA
Series Lamp type Reflector Voltage Ballast Options
4
TX Protected metal halide High pressure sodium PA22C TB Pulse start metal halide Non-EISA ballasts For options and accessories,
175MP 250S PA25D 120 For shipments to U.S. territories, SCWA must be (blank) Standard magnetic see pages 433-439.
200MP 400S 2081,2 specified to comply with EISA. ballast5,6
250MP 2401,2,3 SCWA Super constant wattage autotransformer CWI Constant wattage
RLB Regulated lag ballast isolated5,6
320MP 277
MRB Magnetic regulator
350MP 347 ballast
400MP 4801,2 SCWI Isolated SCWA5,7
450MP
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
22-3/4 24-1/8
(57.8) (61.3)
15-3/4 17-1/8
(40.0) (43.5)
22-3/4
(57.8) 25-7/8
(65.7)
TX PA22C
TX PA25D
Intended Use Optics start ballasts which are 88% assembly meets or exceeds
TX PA25ALE high horizontal illumination. clear, tempered glass lens SCWA option). CSA, NOM Optical mounting: Four 8-32
Ideal for retail areas, light enclosure. UV-stabilized re- or INTL options required corrosion-resistant, tri-
manufacturing areas and flector. Lens is tempered glass for probe start shipments lobular, thread-rolling screws
Acrylume® aisles. Certain airborne for 22" reflector and flat clear outside the U.S. are arranged concentri-
cally around the lamp socket.
contaminants can dimin- acrylic for 25" reflector. Hinge
ish integrity of acrylic. and lens retainer latches Socket: Vertically oriented 16-gauge galvanized steel
Refer to Acrylic Environ- facilitate tool-less removal for mogul base protected exclu- support ring with matching
mental Compatibility maintenance and cleaning. sionary "PINK" socket with keyhole slots is pre-installed
tables on pages 794-795 copper alloy, nickel-plated for vibration-resistant
for suitable uses. Totally enclosed, gasketed screw shell and center con- mounting. For areas where
lens and reflector inhibit the tact. For use with O-rated, reflectors are subject to
Construction entrance of ambient contami- protected metal halide impact (gymnasiums, etc.)
Rugged, heavy-duty, die-cast nants. Meets UL lamp rupture lamps only. add FWG (full wireguard)
aluminum with white poly- containment specifications. to catalog number.
ester powder finish. Electrical Coated lamps provide Installation
components are horizontally optimum performance. Listings
TX PA25ALE Pendant splice box removable
opposed and heat-sinked UL Listed to U.S. and
cast-aluminum box slides on
to ballast housing for cool Electrical Canadian safety standards.
integral die-cast aluminum
operation. Integral splice Ballast: All ballasts are 100% NOM Certified. UL Listed for
housing mounting flange and
box mounting flange ensures factory tested. HPS: Constant damp locations. -30°C to 40°C
mounts to 3/4" pendant con-
structural integrity. wattage autotransformer. ambient operations (high
duit prior to ballast housing
TX PA22GLE MH: 175-400W fixtures ambient HA option for 55°C).
installation. Matching wire
shipped within the U.S.
access cover accepts RELOC®
require super CWA pulse
modular wiring. Complete
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TX 400MP PA22GLE TB SCWA
Series Lamp type Reflector Voltage Ballast Options
5
TX Protected metal halide High pressure sodium PA22GLE TB Pulse start metal halide For options and accessories,
175MP1 250S PA25ALE 120 For shipments to U.S. territories, SCWA must be specified to comply see pages 433-439.
200MP 400S 2082,3 with EISA.
250MP 2402,3,4 SCWA Super constant wattage autotransformer
320MP 277 RLB Regulated lag ballast
350MP 347 Non-EISA ballast
400MP 4802,3 (blank) Standard magnetic ballast6,7
CWI Constant wattage isolated6,7
MRB Magnetic regulator ballast
SCWI Isolated SCWA6,8
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
24-1/2 25
(62.2) (63.5)
17-1/2 18
(44.5) (45.7)
23-3/8 25-7/8
(59.4) (65.7)
TX PA22GLE TX PA25ALE
LITHONIA INDOOR HID
Notes
1 Only available with PA22GLE.
2 Requires CWI or RLB option in Canada for metal halide. Available
for 175-450W only.
3 Requires CWI or MRB option in Canada for high pressure sodium.
Available for 70-400W only.
4 220V and 240V 50Hz and 60Hz ballasts available for use with U.S.,
protected metal halide and high pressure sodium lamps.
5 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V,
347V in Canada).
6 Available for shipments outside of U.S. only.
7 175-400W metal halide only.
8 400W metal halide only.
LOW BAY
Intended Use Optics for probe start shipments Optic Mounting Four 8-32
For areas that require verti-
cal illumination and glare
Injection-molded, virgin
acrylic lens and highly reflec-
outside the U.S. zinc-plated, tri-lobular,
thread-rolling screws are TX A23
TXD A23
control at low mounting tive, white polyester powder Socket: Vertically oriented arranged concentrically
heights. Ideal for general painted reflector. UV stabi- mogul base protected exclu- around the lamp socket.
open areas, retail spaces and lized. Hinge and lens retainer sionary "PINK" socket with 16 gauge, galvanized steel
aisles. Certain airborne latches facilitate tool-less copper alloy, nickel-plated
screw shell and center con-
support ring with matching Hi-Tek®
contaminants can dimin- removal for maintenance keyhole pattern for vibra-
ish integrity of acrylic. and cleaning. Continu- tact. For use with O-rated, tion-resistant mounting.
Refer to Acrylic Environ- ously gasketed refractor and protected metal halide
mental Compatibility reflector inhibits entrance of lamps only. Listings
tables on pages 794-795 outside contaminants. UL listed -30°C to 40°C ambi-
Installation
for suitable uses. ent operations and damp
Pendant splice box: Remov-
Electrical locations. 55°C high ambient
able cast-aluminum box
Construction Ballast: All ballasts are 100% (HA option) available. (HA
slides on integral die-cast
Rugged, heavy-duty, die-cast factory tested. HPS: Constant not available on TXD A23).
aluminum housing mounting
aluminum with white poly- wattage autotransformer. MH: UL wet location available.
flange and mounts to 3/4"
ester powder finish. Electrical 150-400W fixtures shipped Consult factory. UL listed
pendant conduit prior to
components horizontally within the U.S. require super to U.S. and Canadian safety
ballast housing installation.
opposed and heat-sinked CWA pulse start ballasts which standards. NOM Certified.
Matching wire access cover
to ballast housing for cooler are 88% efficient and EISA-
accepts RELOC® modular
operation. Integral splice legislation compliant (must
wiring. Complete assembly
box mounting flange ensures specify SCWA option). CSA,
meets or exceeds UL 50-
structural integrity. NOM or INTL options required
pound pull test.
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TX 400MP A23 TB SCWA
Series Lamp type Reflector Voltage
TX Protected metal halide High pressure sodium A23 TB5
TXD1 175MP 250S 120
200MP 400S 2082,3
250MP1 2402, 3, 4
320MP 277
350MP 347
400MP1 4802,3
450MP
Ballast Options
Pulse start metal halide For options and accessories, see pages 433-439.
For shipments to U.S. territories, SCWA must be specified to comply with EISA.
SCWA Super constant wattage autotransformer (Standard)
RLB Regulated lag ballast
Non-EISA ballast
(blank) Standard magnetic ballast6,7
CWI Constant wattage isolated6,7
MRB Magnetic regulator ballast
SCWI Isolated SCWA6,8
Drawings are for dimensional detail only and may not represent actual
LITHONIA INDOOR HID
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted. Notes
1 TXD consists of TX housing and A23 optical assembly shipped in one carton. Available
22-1/4 with tapped ballast only. Available only in 250MP and 400MP SCWA ballast only.
(56.5) 2 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W only.
3 Requires CSI or MRB option in Canada for high pressure sodium.
Available for 70-400W only.
15-1/4 4 220V and 240V, 50Hz and 60Hz ballasts available for use with U.S. protected metal
(38.7) halide lamps.
5 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada.)
THD1 23 6 Available for shipments outside of U.S. only.
(58.4) 7 175-450W metal halide only.
8 400W metal halide only.
Intended Use Optics required for probe start ship- Optic mounting: Four 8-32
TX A26 excellent glare control at low anodized aluminum reflector. Socket: Vertically oriented concentrically around the lamp
mounting heights. Ideal for Hinge and lens retainer latches mogul base protected exclu- socket. 16-gauge, galvanized
general open areas, retail facilitate tool-less removal for sionary base "PINK" socket steel support ring with
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TX 400MP A26 TB SCWA
Series Lamp type6 Reflector Voltage Ballast Options
4
TX Protected metal halide High pressure sodium A20 TB Pulse start metal halide For options and accessories,
100MP 50S A26 120 For shipments to U.S. territories, SCWA must be specified to comply with EISA. see pages 433-439.
150MP 70S A30 2081,2 SCWA Super constant wattage autotransformer
175MP 100S 2401,2,3 RLB Regulated lag ballast
200MP 150S 277 Non-EISA ballast
250MP 200S 347 (blank) Standard magnetic ballast5,7
320MP 4801,2 CWI Constant wattage isolated5,7
350MP MRB Magnetic regulator ballast
400MP SCWI Isolated SCWA5,8
CONFIGURATIONS Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
REFLECTOR LAMP TYPE unless otherwise noted.
A20 100MP, 150MP, 175MP, 200MP, 250MP, 50S, 70S, 100S, 150S, 200S
A26 250MP, 320MP, 350MP, 400MP 21-1/2 24-1/8 22-1/4
A30 175MP, 200MP, 250MP, 320MP, 350MP, 400MP (54.6) (61.3) (56.5)
14-1/2 17-1/8
(36.8) (43.5) 15-1/4
(38.7)
20-3/4
(52.7) 27-1/2 30-3/4
(69.9) (78.1)
TX A20
TX A26 TX A30
LITHONIA INDOOR HID
Notes
1 Requires CWI or RLB option in Canada for metal halide. Available for 175-450W only.
2 Requires CSI or MRB option in Canada for high pressure sodium.
Available for 70-400W only.
3 220V and 240V 50Hz and 60Hz ballasts available for use with U.S.,
protected metal halide and high pressure sodium lamps.
4 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada).
5 Available for shipments outside of U.S. only.
6 Specify lamp type and reflector, see Configurations table.
7 150-400W metal halide only.
8 400W metal halide only.
LOW BAY
Intended Use Optics shipped within the U.S. modular wiring. Complete
For areas that require high
vertical illumination and
Optics (A121, A125): Anodized
aluminum 12" reflector with
require super CWA pulse
start ballasts which are 88%
assembly meets or exceeds
UL 50-pound pull test. TX A121
wide spacings. Ideal for
aisles, service areas and
parking garages. Certain
one-piece injection-molded
acrylic or polycarbonate
refractor and bottom enclo-
efficient and EISA-legislation
compliant (must specify
SCWA option). CSA, NOM
Optical mounting: Two
3-32 zinc-plated, tri-lobular, TX A125
airborne contaminants
can diminish integrity of
sure. Optics (A162, A165): 16"
high efficiency, optical-
or INTL options required
for probe start shipments
threaded-rolling screws are
arranged concentrically around TX A162
acrylic. Refer to Acrylic
Environmental Compat-
ibility tables on pages
quality, white polyester
powder finish with one-piece
injection-molded acrylic or
outside the U.S.
Socket: Vertically oriented
the lamp socket. Keyhole
slot pattern for vibration-
resistant mounting. TX A165
794-795 for suitable uses. polycarbonate refractor and mogul base protected exclu-
Listings Hi-Tek®
bottom enclosure. Consult sionary "PINK" socket with
Construction copper alloy, nickel-plated UL Listed to U.S. and
factory. Type I and II: Asym- Canadian safety standards.
Housing: Heavy-duty, die- metrical long and narrow screw shell and center con-
cast aluminum halves. Ballast tact. For use with O-rated, NOM Certified. UL Listed for
distribution. Type V: Sym- damp locations and -30°C to
and electrical components are metrical circular distribution. protected metal halide
heat-sinked and horizontally lamps only. 40°C ambient operation (high
OB optics are open bottom. ambient HA option for 55°C).
opposed for cooler operation.
Integral splice box mounting Electrical Installation UL wet location standard on
flange ensures structural Ballast: All ballasts are 100% Pendant splice box threaded 150MP closed bottom only.
integrity. Electrostatically factory tested. HPS: Constant for 3/4" conduit (standard). WL option available on all
applied white polyester wattage autotransformer. Other mounting options others, closed bottom only.
powder paint. MH: 200-400W fixtures available. Matching wire
access cover accepts RELOC®
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TX 250MP A125 TB SCWA
Series Lamp type7 Reflector Voltage Ballast6 Options
5
TX Protected metal halide High pressure sodium A165 TB Pulse start metal halide For options and accessories,
150MP 200S1 A162 120 For shipments to U.S. territories, SCWA must be spcified to comply see pages 433-439.
200MP 250S1 A165OB 2082,3 with EISA.
250MP 400S1 A162OB 2402,3,4 SCWA Super constant wattage autotransformer
320MP1 A125 277 RLB Regulated lag ballast
350MP1 A121 347 Non-EISA ballast7
400MP1 A125OB 4802,3 (blank) Standard magnetic ballast8
A121OB SCWI Isolated SCWA9
CWI Constant wattage isolated8
CONFIGURATIONS Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
REFLECTOR LAMP TYPE unless otherwise noted.
A162, A165 150MP, 200MP, 200S, 250MP, 250S
A1650B, A1650B 320MP, 350MP, 400MP, 400S
A125, A121, A125OB, A1210B 200S, 250S, 400S 17 20-5/8
(43.2) (52.4)
10
(25.4) 13-5/8
(34.6)
12-1/4
(31.1) 16-3/4
(42.6)
TX A121/A125
TX A162/A165
LITHONIA INDOOR HID
Notes
1 Open bottom only.
2 Requires CWI or RLB option in Canada for metal halide. Available in 175-400W.
3 Requires CWI or MRB option in Canada for high pressure sodium. Available 70-400W.
4 220V and 240V 50Hz and 60Hz ballasts available for use with U.S. protected metal
halide and sodium lamps.
5 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V in Canada.)
6 Available for shipments outside of U.S. only.
7 Specify lamp type and reflector, see Configurations table.
8 150-400W metal halide only.
9 400W metal halide only.
ORDERING INFORMATION
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
11-7/8
(30.2)
20-7/8
(53.0)
LITHONIA INDOOR HID
LOW BAY
Intended Use housing for cooler operations. PA22GLE: Injection-molded contact. For use with
For areas that require high
efficiencies, general horizon-
White polyester powder coat
finish. All electrical compo-
virgin acrylic reflector
and Tempered glass lens.
O-rated, protected metal
halide lamps only. SX PA22C
tal/high vertical illumination
and premium contract con-
trol at lowmounting heights.
nents are positioned to assure
unit will hang straight.
Provides approximately
10% uplight. Housing: Integral rapid-latch
steel hook provided with SX PA25D
Ideal for light manufactur-
ing areas, warehouse and
Optics
UV stabilized. Enclosed
PA25ALE: Injection-molded
virgin acrylic reflector and
RELOC® or cord-and-plug
assembly. Optional pendant SX PA22GLE
retail aisles. Steel ballast
housings should be used in
areas with minimal airborne
design with integral flange
includes corrosion-resistant
hinge and latches allowing
flat lens. Provides approxi-
mately 10% uplight.
splice box (PSB) for 3/4"
conduit also available with
mounting options. Optical SX PA25ALE
contaminants. Certain easy maintenance. PA22C: Electrical mounting: Die-formed Acrylume®
airborne contaminants Injection-molded virgin Ballast: Pulse start, 100% 18-gauge galvanized adjust-
can diminish integrity of acrylic reflector and conical factory-tested high power able steel bracket.
acrylic. Refer to Acrylic lens. Coated lamps (must be factor. Meets and exceeds the
ordered separately) provide minimum energy efficiency Listings
Environmental Compat- UL Listed to U.S. and
ibility tables on pages optimal performance. required by the Energy Inde-
Consult factory for compat- pendence and Security Act Canadian safety standards.
794-795 for suitable uses. NOM Certified (See Options).
ibility with corrosive of 2007 (EISA). Ballast will
Construction materials. Meets UL lamp Installation operate pulse UL Listed for damp locations.
Housing: Rugged octagonal rupture containment start lamps only from 120V- Ambient operation: -30°C
to 40°C. 55°C available on SX PA22C SX PA25D
steel housing provides struc- specifications. Provides ap- 277V, 50/60Hz.
tural strength and pleasing proximately 35% uplight. PA25ALE only.
aesthetics. Center- mounted Socket: Vertically oriented
ballast is heat-sinked and all PA25D: Injection-molded vir- mogul base protected exclu-
electrical components are gin acrylic reflector and drop sionary "PINK" socket with
positioned within the vented lens. Provides approximately copper alloy, nickel-plated
25% uplight. screw shell and center
SX PA22GLE SX PA25ALE
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: SX 350MP PA22C TVOLT HEB
Series Lamp type Reflector Voltage Ballast Options
SX Protected metal halide PA22C TVOLT 1 Pulse start metal halide For options and accessories, see pages 433-439.
320MP PA25D 120 HEB HID electronic ballast
350MP PA22GLE 208
400MP PA25ALE 240
277
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
24-3/8 25-3/4
(65.4) 22-3/8 22-7/8
(61.9) (56.8) (56.1)
15-3/4 17-1/8 13-3/4 14-1/4
(40.0) (43.5) (34.9) (38.0)
23-3/8 25-7/8
22-3/4 25-7/8 (65.7)
(57.8) (59.4)
(65.4)
SX PA22C SX PA25D SX PA22GLE SX PA25ALE
Notes
1 Tri-volt electronic ballast capable of operating on any line voltage
between 120V and 277V at 50Hz or 60Hz. Operates 320W, 350W and
400W protected pulse start lamp only.
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: SX 400MP A23 TVOLT HEB
Series Lamp type Reflector Voltage Ballast Options
SX Protected metal halide A23 TVOLT1 Pulse start metal halide For options and accessories, see pages 433-439.
320MP 120 HEB Electronic HID ballast
350MP 208
400MP 240
277
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
23-7/8
(60.6)
15-1/4
(38.7)
23
(58.4)
LITHONIA INDOOR HID
Notes
1 Tri-volt electronic ballast capable of operating on any line voltage
between 120V and 277V at 50Hz or 60Hz opertates 320W, 350W and
400W pulse start lamps only.
LOW BAY
Intended Use housing for cooler operation. and lens retainer latches tact. For use with O-rated,
For areas that require verti-
cal illumination and glare
White polyester powder coat
finish. All electrical compo-
facilitate tool-less removal for
maintenance and cleaning.
protected metal halide
lamps only. SX A26
control at low mounting
heights. Ideal for general
open areas, retail spaces
nents are positioned to assure
unit will hang straight.
Totally enclosed, gasketed
refractor and reflector inhibit
the entrance of ambient con-
Installation
One-piece galvanized hook SX A30
and aisles. Steel ballast Optics
A20 and A26: Injection-
taminants. All distribution and spring steel latch with
cord and plug (SC3P) is
Hi-Tek®
housing should be used in patterns are widespread.
areas with minimal airborne added UV stabilized, virgin standard. Pendant splice box
contaminants. Certain acrylic lens fully fluted anod- Electrical (PSB) with top entry for 3/4"
airborne contaminants ized aluminum reflector. Ballast: Pulse start, 100% conduit also available with
can diminish integrity of Positive-latch refractor clips factory-tested high power mounting options.
acrylic. Refer to Acrylic allow access for maintenance factor. Meets and exceeds the
and cleaning. Continu- minimum energy efficiency Listings
Environmental Compat- UL Listed to U.S. and
ability tables on pages ously gasketed refractor and required by the Energy Inde-
reflector inhibit the entrance pendence and Security Act of Canadian safety standards.
794-795 for suitable uses. NOM Certified. UL Listed for SX A26
of ambient contaminants. 2007 (EISA). Ballast will oper-
Construction Meets UL lamp rupture ate pulse start lamps only damp locations. Ambient
Housing: Rugged octagonal containment specifications. from 120V-277V, 50/60Hz. operations: -30°C to 40°C .
steel housing provides struc-
tural strength and pleasing A30: Injection-molded virgin Socket: Vertically oriented
acrylic lens, fully fluted, mogul base protected exclu- SX A30
aesthetics. Center- mounted
ballast is heat-sinked and all anodized aluminum reflec- sionary "PINK" socket with
electrical components are tor; exclusive spun-fluted copper alloy, nickel-plated
positioned within the vented anodized reflector. Hinge screw shell and center con-
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: SX 400M A26 TVOLT HEB
Series Lamp type Reflector Voltage Ballast Options
1
SX 320MP A26 TVOLT Pulse start metal halide For options and accessories, see pages
350MP A30 208 HEB Electronic HID electronic ballast 433-439.
400MP 240
277
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
25-3/4 23-7/8
(65.4) (60.6)
17-1/8 15-1/4
(43.5) (38.7)
27-1/2 30-3/4
(69.9) (78.1)
SX A26 SX A30
Notes
1 Tri-volt electronic ballast capable of operating on any line voltage
between 120V and 277V at 50Hz or 60Hz. operates 320W, 350W and
400W pulse start lamps only.
Intended Use External hardware is stainless shipped within the U.S. Optical mounting: Four 8-32
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TXF 400MP A30F TB SCWA
Series Lamp type Reflector Voltage Ballast Options
4
TXF Protected metal halide High pressure sodium PA25ALEF TB Pulse start metal halide For options and accessories, see pages
175MP 250S A30F 120 For shipments to U.S. territories, SCWA must be specified to comply with EISA. 433-439.
200MP 400S 2081,2 SCWA Super constant wattage autotransformer
250MP 2401,2,3 RLB Regulated lag ballast
320MP 277 Non-EISA ballast
350MP 347 (blank) Standard magnetic ballast5,6
400MP 4801,2 CWI Constant wattage isolated5,6
MRB Magnetic regulator ballast
SCWI Isolated SCWA5,7
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
23-1/8
25-7/8 (58.7)
(65.7)
15-1/4
18 (38.7)
(45.7)
LITHONIA INDOOR HID
30-3/4 Notes
25-7/8 (78.1) 1 Requires CWI or RLB option in Canada for metal halide. Available for
(65.7) TXF A30F 175-450W only.
TXF PA25ALEF 2 Requires CSI or MRB option in Canada for high pressure sodium.
Available for 70-400W only.
3 220V and 240V 50Hz and 60Hz ballasts available for use with U.S
protected metal halide and high pressure sodium lamps.
4 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V
in Canada).
5 Available for shipments outside of U.S. only.
6 175-400W metal halide only.
7 400W metal halide only.
LOW BAY
TGL
Intended Use supplies high-frequency cur- compliant (must specify Listings
For areas that require rent to the lamp to initiate and SCWA option). CSA, NOM TGL: UL Listed to U.S. and
optimum vertical illumina- maintain a gas discharge for a or INTL options required Canadian safety standards.
tion with glare control at
low mounting heights. Ideal
for parking garages, green-
rated 100,000 hours of life.
Optics
for probe start shipments
outside the U.S.
NOM Certified. TGR: UL
Listed and CSA Certified. NOM
Certified. UL Listed for damp
TGR
houses, garden centers and One-piece, injection- Socket: Vertically oriented locations. Ambient operation: Acrylume®
low-profile industrial aisles. molded, 100% virgin acrylic mogul base protected exclu- -30°C to 40°C (100M); -30°C
Certain airborne con- refractor. TGL Type V (A165), sionary "PINK" socket with to 25°C (250M); -40°C to
taminants can diminish Type II (A162), TGR Type V copper alloy, nickel-plated 25°C (85IL). UL wet location
integrity of acrylic. Refer (A125) and Type 1 (A121) screw shell and center con- standard for 150W metal
to Acrylic Environmental distributions are available. tact. For use with O-rated, halide TGL / TGR. Optional for
Compatibility tables on Polycarbonate refractor protected metal halide all other wattages.
pages 794-795 for suit- available. Consult factory. lamps only.
able uses. Electrical Installation
Construction Ballast: All ballasts are 100% Standard quick-mount
factory tested. HPS: Constant attachment plate mounts TGR
Housing: Rugged, heavy, die-
cast aluminum housing. Stan- wattage autotransformer. to 4" square or octagonal
dard finish is natural aluminum MH: 175-200W fixtures J-box. Factory installed
polyester powder finish. shipped within the U.S. pendant mount option
require super CWA pulse (PM) available.
Induction lighting: High start ballasts which are 88%
frequency generator/ballast efficient and EISA-legislation TGL
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: TGL 200MP A165 TB SCWA
6
Series Lamp Type Reflector Voltage Ballast Options
4
TGL Protected metal halide High pressure sodium A165 TB Pulse start metal halide For options and accessories, see
TGR 100MP 70S A162 120 For shipments to U.S. territories, SCWA must be specified to comply with EISA. pages 433-439.
150MP 100S A125 2081,2,3 SCWA Super constant wattage autotransformer
200MP 150S A121 2401,2 RLB Regulated Lag ballast
Induction 277 Non-EISA ballast
55IL 347 (blank) Standard magnetic ballast5
85IL 480 CWA Constant wattage5
TVOLT7 CWI Constant wattage isolated 5
MRB Magnetic regular ballast
CONFIGURATIONS Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
REFLECTOR unless otherwise noted.
SERIES LAMP TYPE
TYPE V TYPE II
TGL A165 A162 100MP, 150MP, 200MP, 70S, 100S, 150S, 55IL, 85IL
TGR A125 A121 100MP, 70S, 100S, 150S 15-1/2 13-3/8
(39.4) 11-1/4 (34.0)
TGL A165 A162 55IL, 85IL 13-3/8 (28.6) Pendant
(34.0) Pendant
mount Surface mount
Surface mount
mount
12-1/2
16-1/2 (31.8)
(41.9) TGR
TGL
Intended Use GS housing: Square steel pan latch. Coated lamps provide Installation
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: GPV 400M 9AGL TB SCWA
Series Lamp type1 Louver Voltage
2
GPV Vertical lamp Metal halide 16AGL 16-cell, specular clear with glass overlay TB4
GS Enclosed vertical lamp 175M 9AGL 9-cell, specular clear with glass overlay2 120
200M 2082,3
250M 2402,3
320M 277
350M 347
400M
Ballast Options
Pulse start metal halide For options and accessories, see pages 433-439.
SCWA Super constant wattage autotransformer
RLB Regulated lag ballast
For shipments to U.S. territories, SCWA must be specified to comply with EISA.
Non-EISA ballast5
(blank) Standard magnetic ballast6
CWI Constant wattage isolated6
SCWI Isolated SCWA7
Drawings are for dimensional detail only and may not represent actual
mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
D 23-3/4 17-3/4
(60.3) (45.1)
LITHONIA INDOOR HID
23-3/4
(60.3)
26
(66.0)
23-3/4 17 Notes
(60.3) (43.2) 1 Mogul-base lamps required. Coated lamps recommended.
23-3/4 2 Not available on GS products.
175W-350W 400W (60.3) 3 Requires CWI or RLB option in Canada for metal halide. Available for
Depth: 15-7/8 (40.3) 18-1/2 (47.0) GS 175-400W only.
GPV 4 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V
in Canada).
5 Available for shipments outside of U.S. only.
6 175-400W metal halide only.
7 400W metal halide only.
ORDERING INFORMATION For shortest lead times, configure products using bolded options. Example: G2V 400M FW T73 SCWA
Series Lamp type1 Door 8 Shielding Voltage Ballast
G2V Metal halide RW Regressed white aluminum T73 Tempered prismatic glass lens TB6 Pulse start metal halide
G3V 175M FWS Flush white steel2 84YGL Holophane® #8224Y acrylic lens with tempered 120 For shipments to U.S. territories, SCWA must be specified
200M FW Flush white aluminum glass overlay 2084,5 to comply with EISA.
250M A12GL Prismatic acrylic lens with tempered glass overlay 2404,5 SCWA Super constant wattage autotransformer
T73/PCL Tempered prismatic glass lens with polycarbonate standard
320M 277
underlay3 RLB Regulated lag ballast
350M 347
Non-EISA ballast7
400M
(blank) Standard magnetic ballast9
CWI Constant wattage isolated9
SCWI Isolated SCWA10
CONFIGURATIONS Drawings are for dimensional detail only and may not represent actual
DOOR FRAMES G2V G3V mechanical configuration. Dimensions are shown in inches (centimeters)
unless otherwise noted.
RW Option Option
FWS Standard N/A
FW Option Standard
D
23-3/4
(60.3)
26
(66.0)
Notes
1 Mogul-base lamps required. Coated lamps recommended.
LITHONIA INDOOR HID
2 Available with G2V luminaires only.
3 Available with G3V luminaires only.
4 Requires CWI or RLB option in Canada for metal halide. Available for
175-400W only.
5 220V and 240V 50Hz and 60Hz ballasts available for use with U.S,
metal halide lamps.
6 Optional multi-tap ballast (120V, 208V, 240V, 277V; 120V, 277V, 347V
in Canada).
7 Available for shipments outside of U.S. only.
8 See Configurations table for availabilty.
9 175-400W metal halide only.
10 400W metal halide only.
KILOWATCH®
Intended Use each on/off control zone of up to designed for use in indoor for use with all manually
KiloWatch® dual-level HID 30 fixtures. applications with 7' to 8' switched*, KWPC photocell
luminaire option provides mounting heights where a (120/208/240/277/347/480V),
capability to switch ballast KWTX: Control voltage short, wide coverage pattern or KWIR motion sensor
between high-mode and transformer. Provides 120V is desired (14°F to 160°F). (120/208/240/347/480V)
low-mode operation. Choose AC control circuit power for controlled systems.
from 100% to 50% power 208/240/347/480V AC ap- KWIR LT: Passive Infrared
operation or 100% to 50% plications in conjunction with motion sensor. Same as KW4: Reduces wattage by 50%
lumen output operation. KWIR motion sensors. High KWIR sensor designed for (light output reduces by 70-
Luminaires must be com- mode start-up of each lamp low temperature operation 80%). Luminaire supplied with
bined with motion sensors, for 20 minutes performed by (-40°F to 160°F). 277V AC control components.
photocells and/or control KWIR sensors. One KWTX re- For use with KWIR motion
quired for each on/off control KWPC: Photo-diode sensors. sensor controlled systems.
transformers for complete Sensors switch luminaires to
system. Ideal for energy zone of up to 30 fixtures.
low output based on predeter- KW450: Reduces light output
reduction or light level control KWIR: Passive infrared mined ambient illumination by 50% (power reduces by 30-
KWR in warehouses, storage areas, motion sensor. Switches levels (field adjustable). 40%). Luminaire supplied with
parking garages, shipping 120V or 277V control relays 277V AC control components
docks and gymnasiums. in each lighting fixture based Luminaires: for use with KWIR motion
System Features on occupancy. Sensor detects KiloWatch options listed sensor-controlled systems.
Components: moving temperature differ- below only are available with
entials against background Consult factory when
CWA/SCWA ballast configura- using RELOC® wiring with
KWTD: Time delay control. radiation. When motion is tions. The desired option
Solid-state, digital timing detected, lighting system KiloWatch®.
must be designated in the
circuit automatically provides is switched to high mode fixture catalog number. Lamp manufacturers require
high mode startup of each lamp for one to 20 minutes (field 100 hours high-mode
for 15 minutes, guaranteeing adjustable) after motion no KW1: Reduces wattage burn-in of new lamps prior to
KWTXTD lamp stabilization. For 120V AC longer is detected. Sensor by 50% (light output low-mode operation and 15
manually switched or 120V AC includes timing circuit for reduces by 70-80%). to 20 minutes of high-mode
photocell (KWPC) applications. automatic high mode start-up Luminaire supplied with operation thereafter upon
for 20 minutes. Sensor is 120V AC control components start-up.
KWTXTD: Time delay control factory-preset at optimum for use with all manually
voltage transformer. Provides performance angle (43°) and switched*, KWPC photocell Not for use with dual-
120V AC control circuit power can be field-adjusted. Sensor (120/208/240/277/347/480V) wattage-rated lamps.
for 208/240/277/347/480V is designed for use in indoor or KWIR sensor
AC applications controlled (120/208/240/347/480V) * Manual switches and wall
applications with 15' to 35'
by photocells or manual controlled systems. boxes by others.
mounting heights where a
switching*. Includes solid- long and narrow coverage pat-
KW150: Reduces light Consult factory for field start-
state, digital timing circuit for tern is desired (14°F to 160°F).
output by 50% (power up service.
automatic high mode start-up
of each lamp for 15 minutes, KWIR WA: Passive infrared reduces by 30-40%).
guaranteeing lamp stabiliza- motion sensor. Same as KWIR Luminaire supplied with
tion. One KWTXTD required for sensor with wide angle lens 120V AC control components
ORDERING INFORMATION Lead times will vary depending on options. Consult with your sales representative. Example: TH 400MP A16 277 SCWA KW4
Series Lamp type Reflector Voltage Ballast Options
TE High pressure sodium Protected metal halide Metal halide Consult individual product pages for 120 Pulse start metal halide KW11
reflector options.
TH 150S 175MP 175M 208 SCWA Super constant wattage autotransformer KW1502
TPG 250S 200MP 200M 240 KW43
TPGE 400S 250MP 250M 277 KW4504
TX 100S 320MP 320M 347
TGL 350MP 350M 480
TGR 400MP 400M
450MP 450M
1000MP 1000M
LITHONIA INDOOR HID
Notes
1 Manual control switches and boxes by others.
2 Consult factory when using RELOC® wiring.
3 Sensors have automatic timer to keep fixture in high
mode for 20 minutes after start-up.
4 277V control relay for 277V sensor applications only.
50% light output.
CONTROL SYSTEMS
ACCESSORIES/CONFIGURATIONS
ORDER SEPARATELY
SYSTEM FOR 120V AC SYSTEM FOR 208/240/277/347/480V AC
NOMENCLATURE DESCRIPTION (ONE COMPONENT) (ONE COMPONENT)
Time delay control, manually switched. Automatic timer keeps fixtures in high mode for 15
KWTD minutes after start-up.1 N4
MANUAL CONTROLS
Control voltage transformer with time delay. Steps supply voltage down for 120V control.
KWTXTD Automatic timer keeps fixture in high mode for 15 minutes after start-up.1 N4
KWTX Control voltage transformer. Steps supply voltage down for 120V control. N4
KWPC Photocell. N4 N4
PHOTOTCELL CONTROLS KWTD Time delay control. Automatic timer keeps fixture in high mode for 15 minutes after start-up. N4
Control voltage transformer with time delay. Steps supply voltage down for 120V control.
KWTXTD Automatic timer keeps fixture in high mode for 15 minutes after start-up.1 N4
N = Accessory available.
Top View
Distance (feet)
Side View
Mount
height
(feet)
Distance (feet)
LITHONIA INDOOR HID
KWIR-WA Motion Detector Coverage
The sensor coverage shown is under ideal conditions.
Consult specification sheets for specific information.
The KWIR-WA mounted at 8' has coverage zone of 120° and distance of 40'.
Notes
1 Manual control switches and wall boxes by others.
2 Consult factory when using with RELOC® wiring.
3 Sensors have automatic timer to keep fixture in high mode for 20 minutes
after start-up.
4 Must add KW1 or KW150 to fixture description – 120V control.
5 Must add KW4 or KW450 to fixture description – 277V control.
Intended Use flexible metal conduit to operating temperature range SE/SH/SX/SPG Series with
ORDERING INFORMATION Lead times will vary depending on options. Consult with your sales representative. Example: TH 400MP PA22 120 SCWA KW1S
Series Lamp type Reflector Voltage Ballast Options
SE High pressure Protected metal halide Metal halide E17 A20 120 HEB Electronic ballast For options and accessories,
SH sodium1 175MP 175M E22 A125 208 Pulse start metal halide see pages 433-439.
SPG 150S 200MP 200M A15 A165 240 SCWA Super constant wattage
SX 250S 250MP 250M A16 PA16 277 autotransformer
TE 400S 320MP 320M A17 PA22 347 Non-EISA ballast
TH 1000S 350MP 350M A22 PA22C 480 (blank) CWA2
TX 400MP 400M A14 PA25ALE TVOLT
450MP 450M A26 PA25D
1000MP 1000M A30 PA22GLE
See pages 431 for details A23 PA22N
on protected lamps.
10
15
Mount
height 20
(feet)
25
30
LITHONIA INDOOR HID
35
40
45
30 20 10 0 10 20 30
TECHNICAL INFORMATION
Protected Sockets
Mogul Lamp Socket and Metal Halide Mogul Lamp Base Differences
Lithonia Lighting only accepts orders for indoor metal halide products that can use either ANSI Type-E Standard Mogul Base Sockets – Standard sockets are constructed of porcelain and are white in color. The
(enclosed) or ANSI Type-S (suitable) rated lamps if those fixtures also have a tempered glass lens. This means center contact tab will accept ANSI Type E, S and O rated lamps. These sockets will continue to be used for
all indoor metal halide products with open reflectors OR with acrylic or polycarbonate lenses are metal halide HID lamps in indoor luminaires with enclosed optics.
only available with protected (pink) sockets.
Protected Mogul Base Sockets – Protected sockets are constructed of porcelain and are pink in color. The
ANSI Type E – Type E metal halide lamps are enclosed-rated and only suitable for enclosed luminaires center contact tab is surrounded by a barrier that excludes ANSI Type E and S lamps by preventing contact
that have a glass lens or plastic lens rated for arc tube containment. These lamps have a standard mogul base between the center pin on the lamp base and center tab on the lamp socket. Type O rated lamps have a nar-
design with a broad contact point as shown. Typical for 175-1500W metal halide lamps. row center pin that fits in the barrier to make contact with the center tab. These sockets will be required for
indoor HID metal halide luminaires with open optics to comply with 2005 NEC.
ANSI Type S – Type S metal halide lamps are rated suitable for use in enclosed luminaires or in open lumi-
naires if certain lamp manufacturer operating conditions are followed. These lamps have a standard mogul
base design with a broad contact point as shown. The Type S lamp rating is currently applied to metal halide
lamps 350W or greater for replacement of existing lamps.
ANSI Type O – Type O metal halide lamps are open-rated protected lamps for use in open or enclosed Type O – "EX" Type E and S
luminaires. These lamps have "EX" style exclusionary bases designed specifically for operation with pink mogul base mogul base
protected sockets. The mogul bases of these lamps have a narrow contact point designed for protected lamp Type O lamp in Type E and S lamp Type O lamp in Type E and S
sockets. Type O lamps most commonly have a cylindrical quartz barrier around the arc tube while some white standard in white standard pink protected lamp in pink
ceramic metal halide arc tubes are wrapped with wire. Typical for 175-1500W metal halide lamps. mogul socket mogul socket mogul socket protected
mogul socket
Fixture Weights
HOUSING LAMP TYPE REFLECTOR WEIGHT (LBS) HOUSING LAMP TYPE REFLECTOR WEIGHT (LBS) HOUSING LAMP TYPE REFLECTOR WEIGHT (LBS)
TPG 150S, 200S, 250S,400S PG16 34 TX 250S PA22GLE 35.8 TH 250S PA22N 31
TPG 400S, 1000S PG21 55 TX 250S PA25ALE 39 TH 400S PA22 31
TPG 400M PG16 34 TX 400S PA22GLE 35.8 TH 400S PA22N 31
TPG 400M, 1000M PG21 55 TX 400S PA25ALE 39 TH 1000S PA25 48
TPG 150S, 200S, 250S,400S PG16A 36.2 TX 250M PA22GLE 35.8 TH 175M PA22E 25
TPG 400S, 1000S PG21A 55 TX 250M PA25ALE 39 TH 250M PA22E 25
TPG 400M PG16A 36.2 TX 400M PA22GLE 35.8 TH 400M PA22 31
TPG 400M, 1000M PG21A 55 TX 400M PA25ALE 39 TH 400M PA22L 31
TPGE 150S, 200S, 250S,400S PG16GLE 36.8 TX 250S PA22C 31 TH 400M PA22N 31
TPGE 400S, 1000S PG21GLE 55 TX 250S PA25D 34 TH 1000M PA25 48
TPGE 175M, 250M, 400M PG16GLE 36.8 TX 400S PA22C 31 TH 70S, 100S, 150S A17 25
TPGE 400M, 1000M PG21GLE 55 TX 400S PA25D 34 TH 250S, 400S A17 25
TPGE 150S, 200S, 250S,400S PG16AGLE 38.8 TX 250M PA22C 31 TH 1000S A22 56
TPGE 400S, 1000S PG21AGLE 55 TX 250M PA25D 34 TH 400M A17 25
TPGE 175M, 250M, 400M PG16AGLE 38.8 TX 350M PA22C 31 TH 1000M A22 56
TPGE 400M, 1000M PG21AGLE 55 TX 350M PA25D 34 TH 70S, 100S, 150S A16 24.2
TXF 250S PA25ALEF 37 TX 400M PA22C 31 TH 250S, 400S A16 24.2
TXF 250S A30F 29.5 TX 400M PA25D 34 TH 175M A16 24.2
TXF 400S PA25ALEF 37 TX 50S, 70S, 100S A20 17 TH 250M A16 24.2
TXF 400S A30F 29.5 TX 150S, 200S, 250S A20 17 TH 400M A16 24.2
TXF 250M PA25ALEF 37 TX 250S, 400S A26 32 TH 250S A16GL 25
TXF 250M A30F 29.5 TX 100M, 175M, 250M A20 17 TH 400S A16GL 25
TXF 400M PA25ALEF 37 TX 250M, 400M A26 32 TH 175M A16GL 25
TXF 400M A30F 29.5 TX 250S, 400S A30 25.5 TH 200M A16GL 25
TGR 70S 14 TX 250S, 400S A23 21 TH 250M A16GL 25
TGR 100S 14 TX 250M, 400M A23 21 TH 400M A16GL 25
TGR 150S 14 TX 70S, 100S 150S A125 23 TH 250S A15 21
TGR 100M 14 TX 200S, 250S A125OB 23 TH 400S A15 21
TGL 70S 15 TX 200S, 250, A165 30 TH 400M A15 21
TGL 100S 15 TX 400S A1650B 30 TH 150S A14 27
LITHONIA INDOOR HID
TGL 150S 15 TX 100M A125 23 TH 200S A14 27
TGL 100M 15 TX 100M, 175, 250M A165 30 TH 250S A14 27
TGL 175M 15 TX 400M A165OB 30 TH 400S A14 27
TGL 250M 15 TX 70S, 100S, 150S A121 23 TH 400M A14 27
TX 200S, 250S A121OB 23 TE 70S, 100S, 150S, 200S E17 31
TX 200S, 250S A162 30 TE 250S, 400S E17 31
TX 400S A162OB 30 TE 400S, 1000S E22 50
TX 100M A121 23 TE 175M, 250M, 400M E17 31
TX 100M, 175M, 250M A162 30 TE 400M, 1000M E22 50
TX 400M A1620B 30
DF Double fuse. Use with 208V, 240V, 480V. Externally accessible in-line fusing isolates luminaire from circuit. Specify tap voltage if
combined with multi-tap ballast (TB2=208V, TB3=240V) or five-tap ballast (TBV2=208V, TBV3=240V, TBV6=480V).
HA (Die-cast aluminum)
HA High ambient. Allows the industrial luminaires to be operated in higher ambient temperatures. TX low bay series is 55°C. TH, TE, TPG,
TPGE high bay series is 65°C. Large die-cast aluminum ballast housing included for TH, TE, TX, TPG, TPGE. Steel housing SH, SX, SPG
DF series is 55°C and includes external heat shield.
WL Wet location label. Signifies that the luminaire meets all UL requirements for proper, safe operation in environments subject to spray of
non-corrosive and nonflammable liquids. Fixture requires rigid pendant mounting or wet location HC3PC3RWT assembly.
HA (Steel housing)
TR Remote ballast luminaire. Add TR to end of complete fixture catalog number. Includes ballast housing, optic and appropriate remote
optical splice box. Does not include interconnecting wiring. Ballast, optic and splice box ship separately.
RC3NP Remote ballast luminaire with pre-wired cord. Add RC3NP to end of complete fixture catalog number. Includes ballast housing, optic
and appropriate remote optical mounting box and 3' of pre-wired cable harness with male and female 20A twist lock plug (C3NP)
factory attached. Ballast, optic and splice box ship separately.
TR RC3NPWL Remote ballast luminaire with pre-wired cord for wet location. Add RC3NPWL to end of complete fixture catalog number. Same as
RC3NP except listed for wet location.
SCK Safety chain kit. Kit includes chain and attachment hardware for field installation. Add SCK (5’), SCK84 (7’), SCK120 (10’) to fixture
catalog number or order separately as SCK (5’), SCK84 (7’), SCK120 (10’).
Splice box
Optic Options & Accessories
CF Charcoal filter. Used with enclosed and gasketed luminaires. Filter prevents particulate contaminants from entering the optical
assembly during start-up and cool-down periods. Filter consists of activated charcoal granules freely suspended between multiple
layers of polyester filtering material.
GL17/GL22 Glass lens for TH A17/A22. Frequent cleaning maintains performance. (Does not meet UL lamp rupture containment specifications.)
RK1 MHINGE U kit must be specified when ordering lens separately for field modification.
SCK
LITHONIA INDOOR HID
CF
KW4 KiloWatch® 50% power reduction. 277V AC control circuit for dual-level control system. Requires additional system components.
See KiloWatch® data (pages 428-429) or consult factory.
KW150 KiloWatch® 50% lumen reduction. 120V AC control circuit for dual-level control system. Requires additional system components.
See KiloWatch® data (pages 428-429) or consult factory.
KW450 KiloWatch® 50% lumen reduction. 277V AC control circuit for dual-level control system. Requires additional system components.
See KiloWatch® data (pages 428-429) or consult factory.
KW1S KiloWatch® II 50% power reduction. Integral sensor unit for individually controlled dual-level system.
KW1S
See KiloWatch® II data (page 430) or consult factory.
KW1SLT KiloWatch® II 50% power reduction for low temperature. Integral low temperature sensor unit for individually controlled dual-level system.
See KiloWatch® II data (page 430) or consult factory.
ISM Individually sensored motion detector. 50% power reduction for individually controlled HEB electronic dimming ballast.
Consult factory for details.
HC3KP Hook, 3’ cord and NEMA twist-lock plug for KiloWatch®. Identical in function to HC3P except with NEMA L23-20P plug configuration
for KiloWatch®.
LC3P Loop, 3’ cord and NEMA twist-lock plug. For use where receptacle and support means are provided by others. Includes die-cast ISM
aluminum loop, 3’ of 16-gauge, 105°C cord and NEMA configuration twist-lock plug. Add LC3P to fixture catalog number for factory
installed or order separately as LC3P Lx-xxP (Lx-xxP denotes plug configuration. Specify from NEMA Plug Table below). Height 3-1/2”.
LC3KP Loop, 3’ cord and NEMA twist-lock plug for KiloWatch®. Identical in function to LC3P except with NEMA L23-20P plug configuration for
KiloWatch®.
KW1 KW4 KW150 KW450 KW1S KW1SLT ISM HC3P HC3KP LC3P LC3KP
SHIPS ATTACHED N N N N N N N N N N N
SHIPS SEPARATELY N N LC3P/LC3KP
LOCS Loop, cord and RELOC OCS connector. For use where support means are provided by others. Requires RELOC wiring system. Includes
SC3PD HOCS die-cast aluminum loop, 5’ of 16-gauge, 105°C white cord and Lithonia RELOC module. Allows the desired hot conductors needed
to energize the fixture to be selected in the field. Allows fixture to be removed from line without interruption of branch circuit.
Factory prewired. Height 3-1/2”. In Canada, available in 120V or 347V only. To order, specify voltage. For additional information,
see RELOC OCS component on page 495.
OCS Hook, cord and RELOC OCS connector. For use where support means are provided by others. Requires RELOC wiring system.
Includes steel hook, 5’ of 16-gauge, 105°C white cord and Lithonia RELOC module. For SH/SX/SPG steel housing only. Allows the
desired hot conductors needed to energize the fixture to be selected in the field. Allows fixture to be removed from line without
interruption of branch circuit. Factory prewired. Height 3-1/2”. In Canada, available in 120V or 347V only. To order, specify volt-
age. For additional information, see RELOC OCS component on page 495.
LCKPP Loop, cord and plug for KiloWatch®. Use with PPHKR and TPHKR only. Includes loop,14” of 16-gauge, 105°C cord and twist-lock
NEMA L23-20P plug for power hooks for KiloWatch®. Receptacle is part of TPHKR and PPHKR accessory. Factory installed.
PPH Pendant power hook. UL listed as primary disconnect, load break device. Threaded 3/4” top entry. Fixture requires LCPP op-
tion (loop, cord and plug). Add PPH to fixture catalog number or order separately as PPH xxx. (xxx – denotes voltage. Specify
120, 208, 240, 277, 347, 480.) Height 5-1/8”; width and depth 4-1/2”.
LCPP/LCKPP PPHKR Pendant power hook for KiloWatch® system. UL listed as primary disconnect, load break device. Threaded 3/4” top entry. Fixture
requires LCKPP option (loop, cord and plug for KiloWatch® system). Add PPHKR to fixture catalog or order separately as
PPHKR xxx. (xxx – denotes voltage. Specify 120, 208, 240, 277, 347, 480.) Height 5-1/8”; width and depth 4-1/2”.
TPH Through-wire power hook. UL listed as primary disconnect, load break device. Permits side entry for 1-1/4” or 3/4” conduit through
PPH/PPHKR concentric knockouts. Fixture requires LCPP option (loop, cord and plug). Add TPH to fixture catalog number or order
separately as TPH xxx. (xxx – denotes voltage. Specify 120, 208, 240, 277, 347, 480.) Height 6-1/4”; width and depth 4-1/2”.
LITHONIA INDOOR HID
TPHKR Through-wire power hook for KiloWatch® system. UL listed as primary disconnect, load break device. Permits side entry for
1-1/4” or 3/4” conduit through concentric knockouts. Fixture requires LCKPP option (loop, cord and plug for KiloWatch®
system). Add TPHKR to fixture catalog or order separately as TPHKR xxx. (xxx – denotes voltage. Specify 120, 208, 240, 277, 347,
480.) Height 6-1/4”; width and depth 4-1/2”.
TOBP Through-wire outlet box plug-in. Provides plug-in flexibility of conventional power hook and reduces overall height. Permits side
entry for 1-1/4” or 3/4” conduit through concentric knockouts. Female receptacle part of TOBP box ships separately. Male plug is TOB
factory installed to ballast housing. Not rated as a load break device. Height 2-7/8”; width and depth 4-1/2”.
PBP Pendant box plug-in. Pendant-mount plug-in outlet box provides plug-in flexibility of conventional power hook. Female receptacle TOBP
part of PBP box ships separately. Male plug is factory-installed to ballast housing. Not rated as a load break device. Threaded 3/4”
entry permits top entry of pendant stem. Height 4-1/2”; width and depth 4-1/2”.
PSB Pendant splice box. Permits pendant mounting of TG and SH/SX/SPG steel housing series. TG box has 3/4” threaded top entry.
SH/SX/SPG box has 3/4" top knockout.
PM Pendant splice box. Permits pendant mounting of TGL and TGR series. Die-cast aluminum box has 3/4” threaded top entry. PBP
PSB
Wireguards for Acrylume® Prismatic Acrylic High Bays & Low Bays
FWG Full wireguard. Use with the TH high bay or TX low bay Acrylume® fixtures. Attaches to bottom of ballast housing.
Ships separately as: FWG U (Unit).
FIXTURE SERIES AND SIZE CYLINDER DCY SQUARE DSQ HEXAGONAL DHX DIAMETER HEIGHT
TH A16 and TH A17 DCY19 400 (color) DSQ19 400 (color) DHX19 400 (color) 19” 30”
TH A17 with WGA, WGG DCY22 400 (color) DSQ22 400 (color) DHX22 400 (color) 22-1/2” 30”
TH A22 DCY24 400 (color) DSQ24 400 (color) DHX24 400 (color) 24” 30”
TH A22 with WGA, WGG DCY26 1000 (color) DSQ26 1000 (color) DHX26 1000 (color) 26” 30”
TE E17 DCY22 400 (color) DSQ22 400 (color) DHX22 400 (color) 22-1/2” 30”
TE E22 DCY26 1000 (color) DSQ26 1000 (color) DHX26 1000 (color) 26” 30”
FWG DCY
24-gauge steel construction with baked polyester enamel finish. Designed for pendant mounting on rigid conduit only. Not for use on swivel
hangers or any self-leveling hanging device. Available in all architectural colors. Custom colors may involve substantial setup fees; consult factory.
Mounting and fixture attachment hardware not included.
LITHONIA INDOOR HID
Mounting Hooks
HKM Fixture hook male. Die-cast aluminum construction with spring steel safety clasp. Overall height is 3-3/4” including 1” of threaded
nipple. Thread diameter is 3/4”.
HKF Fixture hook female. Die-cast aluminum construction with spring steel safety clasp with coupling added for female entry. Overall
height is 5-1/4” including threaded coupling. Thread diameter is 3/4”.
HKMG Fixture hook male grommeted. Die-cast aluminum construction with spring steel safety clasp. Gasketed cord exit design keeps dirt
from entering hook/cord entry. Overall height is 3-3/4” including 1” of threaded nipple. Thread diameter is 3/4”.
HKM HKF
LPM Fixture loop male. Die-cast aluminum construction with closed loop design. Overall height is 3-3/4” including 1” of threaded nipple.
Thread diameter is 3/4”.
LPF Fixture loop female. Die-cast aluminum construction with closed loop design with coupling added for female entry. Overall height is
5-1/4” including threaded coupling. Thread diameter is 3/4”.
LPMG Fixture loop male grommeted. Die-cast aluminum construction with closed loop design. Gasketed cord exit design keeps dirt from
entering loop/cord entry. Overall height is 3-3/4” including 1” of threaded nipple. Thread diameter is 3/4”.
HKMG LPM
Mounting Bars
SMB Single mounting bar. White painted steel channel with 3/4” pipe couplings suspend remote ballast housing at one end with remote
reflector assembly at the other. SMB includes end snap-in closure strips for wire access. Order as SMB18 for 18” (overall length) or
SMB24 for 24” (overall length). Center line of pipe couplings are 3” from each end.
TMB Twin mounting bar. White painted steel channel with 3/4” pipe couplings suspends two complete fixtures, one at each end. Order as
TMB30 for 30” (overall length) or TMB48 for 48” (overall length). Centerlines of pipe couplings are 3” from each end.
LPF LPMG
Wireguards for Hi-Tek® Aluminum High Bays & Low Bays
WGA Wireguard for Hi-Tek® open aluminum high bay reflectors. Use with TH A15/A16/A17/A22 and SH A15/A16 open aluminum reflector
high bays. Add WG to fixture catalog number or order separately as WGxxx. (xxx – denotes reflector. Specify A15, A16, A17, A22.)
2-7/8
(7.3) WGG Wireguard for enclosed high bay reflectors. Use with TE E17/E22; TH A17 with GL17/A22 with GL22; TPGE PG16GLE/PG16AGLE/
PG21GLE/PG21AGLE reflector high bays. Wireguard is factory installed to glass lens door. Must be ordered with fixture. Add WG to
SMB
fixture catalog number.
2-7/8 WG Wireguard for Hi-Tek® aluminum low bays. Use with TX A20/A23/A26/A30 or SX A23. Must be ordered with fixture. Add WG to fixture
(7.3) catalog number. Wireguard is factory attached to lens door. Add WG to fixture catalog number.
TMB
WGA
LITHONIA INDOOR HID
WGG
HKM HKF HKMG LPM LPF LPMG SMB TMB WGA WGG WG
SHIPS ATTACHED N N
WG
SHIPS SEPARATELY N N N N N N N N N
TH A16/A16GL
TX A125/A165
TH PA22/PA25
TXF PA25ALEF
THD A15/A16
TH A17/A22
TX PA22GLE
TX PA25ALE
TE E17/E22
SPG PG15
TX PA25D
TX PA22C
TXF A30F
TXD A23
SH PA22
SH A14
SH A15
SH A16
TH A14
TH A15
TX A20
TX A23
TX A26
TX A30
SX A23
TPGE
TPG
TGR
TGL
SF N N N N N N N N N N N N N N N N N N N N N N N N N N N
DF N N N N N N N N N N N N N N N N N N N N N N N N N N N
HA(55 °C) O O O O O O O N N N N N N N N N N N N N N N
HA(65°C) N N N N N N N N
WL N N N N N N N O O N N N N
BALLAST
TR N N N N N N N N N N N N N N N N N
HOUSING
RC3NP N N N N N N N N N N N N N N N N N
RC3NPWL N N N N N N N N N N
SCK N N N N N N N N N N N N N N N N N N N N N N N N N
SCK84 N N N N N N N N N N N N N N N N N N N N N N N N N
SCK120 N N N N N N N N N N N N N N N N N N N N N N N N N
CF N N
OPTIC GL17/GL22 O N
T73 N N
EC N N N N N N N N N N N N N N N N N N N N N N N N N
QUARTZ LAMP QRS N N N N N N N N N N N N N N N N N N
QRSTD N N N N N N N N N N N N N N N N N N N N N N N
KW1 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
KW4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
KW150 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
HID DIMMING KW450 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
KW1S N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
KW1SLT N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
ISM N N N N N N
HC3P N N N N N N N N N2 N2 N N N N N N N N N
HC3KP N N N N N N N N N N N N N N N N N
LC3P N N N N N N N N N2 N2 N N N N N N N N N
CORD
LC3KP N N N N N N N N N N N N N N N N N
MOUNTING
HC3PC3RWT N N2 N2 N N N N N N N N N N N
SC3P N N N N N N
SC3PD N N N N N N
HOCS N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5
RELOC
LOCS N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5
MOUNTING
OCS N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5 N3,4,5
LCPP N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
LCKPP N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
POWER PPH N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
HOOK PPHKR N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
TPH N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
TPHKP N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
TOB N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
TOBP N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4
BOX
PBP N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4 N3,4
MOUNTING
PSB N N N N N O O O O O O O N O O O O O O O O O O O O
PM N N
HKM N N N N N N N N N N N N N N N N N N N N N N N N N
HKF N N N N N N N N N N N N N N N N N N N N N N N N N
MOUNTING
HKMG N N N N N N N N N N N N N N N N N N N N N N N N N
HOOKS AND
LPM N N N N N N N N N N N N N N N N N N N N N N N N N
LOOPS
LPF N N N N N N N N N N N N N N N N N N N N N N N N N
LPMG N N N N N N N N N N N N N N N N N N N N N N N N N
SMB18 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6
MOUNTING SMB24 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6 N4, 6
BARS TMB30 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
TMB48 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4 N4
WGA N N N N N
WGG N9
WG N N N N N N
WIRE GUARDS
WGPG N
GFWG N
FWG N N N N N N
LITHONIA INDOOR HID
DCY N7 N 7
N 7
N 7
DECORATIVE
DSQ N7 N7 N7 N7
SHIELDS
DHX N7 N7 N7 N7
CR N8 N8 N8 N8 N8 N 8, 10 N 8, 10 N 8, 10 N8 N8 N8 N8 N8 N8 N8 N 8, 10 N 8, 10 N 8, 10 N 8, 10
PAINT
CRT N8 N8 N8 N8 N8 N 8, 10 N 8, 10 N 8, 10 N8 N8 N8 N8 N8 N 8, 10 N 8, 10 N 8, 10 N 8, 10
LPI N N
LAMP
W/LAMP N N N N N N N N N N N N N N N N N N N
Notes 4 Cannot be combined with WL option. 8 Consult factory for environmental compatibility.
1 Not available on all wattages and voltages. Consult factory. 5 Available in 120V or 347V in Canada. 9 Must be ordered with tempered glass(GL17/GL22) door enclosure.
2 Requires PM option. 6 Requires TR ballast option. 10 Housing only.
O = Standard 3 Must specify voltage tap for TB and TBV in catalog number voltage 7 Pendant mount on rigid conduit. Not for use with any self-leveling
N = Option available field. (See NEMA PLUG Chart). hanger.