1 Installation Procedure .................................................................................................................... 4 
1.1 General Procedure ....................................................................................................... 4 
1.2 Recording Data Checking Procedure .......................................................................... 4 
2 Component List .............................................................................................................................. 5 
2.1 SLT-18C VDR System Drawing ................................................................................. 5 
2.2 Standard Components ................................................................................................. 6 
2.3 Optional Components.................................................................................................. 6 
3. Installation..................................................................................................................................... 7 
3.1 Installation of Protective Data Capsule SLT-18-P1 ..................................................... 7 
3.2 Installation of Float Free Protective Data Capsule SLT-18C-FP1 ............................... 8 
3.3 Installation of Recording Control Unit SLT-18C-RCU ............................................... 9 
3.4 Installation of Microphone Unit SLT-18C-MU ........................................................ 10 
3.5 Installation of Power Supply Box SLT-18C-PU........................................................ 11 
3.6 Installation of Data Acquisition Unit SLT-18C-DAU ............................................... 12 
3.7 Installation of Serial Port Device Junction Box ........................................................ 14 
3.8 Installation of Data Input Unit SLT-18C-DIU ........................................................... 14 
3.9 Installation of Net Video Capture Unit SLT-18C-NV4 .......................................... 16 
4. System Cabling ........................................................................................................................... 17 
4.1 External Connection of Recording Control Unit ....................................................... 18 
4.2 Internal Connection of the Recording Control Unit .................................................. 25 
5. Alarm Panel ................................................................................................................................. 31 
5.1 Alarm Panel Functions Introduction ......................................................................... 31 
5.2 Error Code List of the Alarm Panel ........................................................................... 32 
6. System Connection Drawings ..................................................................................................... 33 
6.1 The Diagram of Power Supply Unit .......................................................................... 33 
6.2 System Maintenance Device Connection Drawing ................................................... 35 
6.3 Internal Cable Connection of Recording Control Unit.............................................. 36 
6.4 External Power Connection Drawing Of Recording Control Unit ............................ 37 
6.6 External Cable Connection of Data Acquisition Unit ............................................... 39 
6.7 PDC Connection Drawing......................................................................................... 40 
6.8 FPDC Connection Drawing ...................................................................................... 41 
6.9 Net Video Capture Unit Connect Drawing................................................................ 42 
6.10 Connection Drawing For Junction Box for Devices with Serial Port ..................... 43 
7. Data Recording and Data Comprising ........................................................................................ 44 
7.1 Data Recording ......................................................................................................... 44 
7.2 Data comprising ........................................................................................................ 44 
8. System Software Construction .................................................................................................... 49 
8.1 Remote desktop connection software ........................................................................ 49 
8.2 Main Controlling Software Instruction ..................................................................... 51 
8.4 Playback Software Instruction .................................................................................. 68 
9. Long-term storage medium ......................................................................................................... 79 
10.Document Placement Guide....................................................................................................... 81 

2
SEALANTERN ELECTRONICS CO., LTD

11. COMMISSIONING & ANNUAL INSPECTION TEST REPORT .......................................... 82 

Note:
Functions and technical parameters shall be subject to any changes duo to our improving
without additional notices.

Version:5.0 Modified Date:2015-04-08

SEALANTERN ELECTRONICS CO., LTD


ADDR: NO.6 ZHUYUAN ROAD, HUAYUAN INDUSTRIAL
DISTRICT TIANJIN 300384, P.R. CHINA
TEL: +86-22-23078176/77/78
FAX: +86-22-23078179
http://www.sealantern.com.cn
Email:slt@sealantern.com.cn

3
SEALANTERN ELECTRONICS CO., LTD

1 Installation Procedure

1.1 General Procedure

a) Mounting the necessary units


b) Wiring the cables in according with the installation drawings.
c) Wiring the cables in the sensors and devices in according with the installation drawings
d) Checking power supply and signal which wiring condition.
e) Staring the device and checking the recording data.

1.2 Recording Data Checking Procedure

1) Personal computer setting


a) Set the IP address as “192.168.0.5” for the personal computer.
b) Set sub-net mask as “255.255.255.0”.
c) Connect PC ETHERNET interface to “Playback” interface on the bottom board of the
recording control unit with ETHERNET cable.

2) Data checking: Checking the recorded data by playback software if it is satisfied,refer to


the instruction of clause 10.3 of the guide.

3) Current IP address of the control box: 192.168.0.100


4) IP address of the PDC: 192.168.0.1
5) IP address of the FPDC: 192.168.0.2

4
SEALANTERN ELECTRONICS CO., LTD

2 Component List

2.1 SLT-18C VDR System Drawing

Fig.2-1 VDR System Drawing

5
2.2 Standard Components

SLT-18C VDR Standard Components List


S/N Name Type Quantity Remark
1 Protective Data Capsule SLT-18-P1 1
2 Float free Protective Data Capsule SLT-18C-FP1 1
SLT-18C-RC
3 Recording Control Unit 1
U
4 Indoor Microphone SLT-18C-MU 4 Cable for choice (20m)
SLT-18C-WP Cable for choice (25m)
5 Waterproof Microphone 2
MU
6 Power Supply Unit SLT-18C-PU 1
SLT-18C-DA
7 Data Acquisition Unit 1
U
8 Net Video Capture Unit SLT-18C-NV4 1
2
3X1mm From Power supply unit to
9 Power Cable 1
Recording Control Unit (3m)
2X2X0.5mm2 From Power supply Unit to
10 RS-232 Cable 1
Recording Control Box (3m)
11 Playback Device Cable +5e net cable 1 (10m)
2
12 PDC Voltage Cable 3X1mm 1 (20m)
2
13 PDC Signal Cable 2X2X0.5mm 1 (20m)
2
14 FPDC Cable 1X6X0.5 mm (20m)
15 System Installation CD 1
16 System Installation &Operation Guide 2

2.3 Optional Components

S/N Name Type


1 Serial Port Device Junction Box SLT-18C-SJB
2 Data Input Unit SLT-18C-DIU
3 Microphone Cable 6X0.5mm2
4 VHF Cable 2X0.5mm2
5 Radar Video Cable VGA Standard Cable
6 Serial Port Signal Cable 2X0.5mm2
7 Power Cable 3X1mm2
SEALANTERN ELECTRONICS CO., LTD

3. Installation

3.1 Installation of Protective Data Capsule SLT-18-P1

3.1.1 Selection of Mounting Location

The protective data capsule shall be installed on the external deck of the vessel near the bridge to
make the most possibility of its survival and reclaim after incident. The location of the capsule
shall be far way from riggings and other potential barriers but adjacent to the centerline of the
vessel as much as possible. The following circumstances shall be considered in the installation:
(1) Far away from fuel or other potential fire source
(2) Far away from the objects which may cause mechanical damages to the capsule
(3) A working environment with reliability and continuity.
(4) Easy to approach to replicate the recorded data and for routine maintenance
(5) There is enough space for capsule location for easy underwater disassembly and reclaim
of the diver and remoter control machine. The capsule shall be installed in an appropriate
position on the deck and be far from the compass in the minimum safe distance 380mm.

3.1.2 Mounting Steps

(1) Connect the protective data capsule with the deck by following the steps as below. Refer
to the figure 3-1, 3-2 for the exterior drawing and mounting dimension of the capsule.
a) Erase the paint on the mounting hole and underside of the capsule as well as the
mounting side of the deck. Process the mounting hole according to the thread hole on
the mounting underside on the vessel or the mounting bracket.
b) Connect the mounting underside of the capsule with the deck by M12 bolts.
c) Fix the underside and the thread by the knock-down Q98-1 glue.
(2) The communicating cable (Ethernet cable) and the power cable shall be covered with the
waterproof PVC pipe, laid and fixed between the junction box of the capsule and the
capsule itself.
(3) Connect the communicating cable of the capsule with the VDR in the PDC junction box
SLT-18C-PJB(optional) followed the interface marker of the capsule.
(4)Supply power to the capsule.
(5) Ensure the Ethernet has been established between the capsule and the VDR and the
communication has been carried out normally by checking the VDR’ mainframe.
(6) Power off after adjustment.

7
SEALANTER
RN ELECTRON
NICS CO., LTD
D

Figg.3-1 Undersidee Installing Dim


mension of the PDC
P

Fig.3--2 Outline of th
he PDC

3.2 Installation
n of Float Free
F Protecctive Data Capsule
C SL
LT-18C-FP11

The float-free prootective data capsule shalll be installedd on the exterrnal deck of thhe vessel neaar the
bridgge. The locattion of the flloat-free capssule shall be far way from m riggings annd other poteential
barriiers but adjacent to thee centerline of the vesssel as muchh as possiblee. The follo owing
circuumstances shhall be consideered in the innstallation:
(1) Far awayy from fuel orr other potenttial fire sourcce
(2) Far awayy from the obbjects which may
m cause meechanical dam mages to the ccapsule
(3) A workinng environmeent with reliaability and con ntinuity.

8
SEALANTERN ELECTRONICS CO., LTD

(4) Easy to approach to replicate the recorded data and for routine maintenance
The capsule shall be installed in an appropriate position on the deck and be far from the compass
in the minimum safe distance 480mm.The FPDC on the left shall be installed to the box on the
right in Fig.3-3,then the box shall be installed in an appropriate position on the deck.

Fig.3-3 Installing Dimension of the FPDC

3.3 Installation of Recording Control Unit SLT-18C-RCU

3.3.1 Selection of Mounting Location

The recording control unit shall be installed in the bridge, and its mounting position shall meet the
following requirements:
(1) Far way from other electric devices, such as some intensive electromagnetic releasing
equipment like the radar receiver and radiocommunication equipment.
(2) Far way from the potential mechanical damage caused barriers
(3) A working environment with reliability and continuity.
(4) Easily access for replicating recorded data and routine maintenance.
(5) Keep the installing distance with other connecting devices in the bridge as short as
possible.

3.3.2 Mounting Steps


(1) Fix the mounting bracket on the wall followed the mounting instruction.
(2) Fix the back of the recording control unit on the mounting bracket and make the mounting
holes right to the responding holes on the bracket. Mount the nuts on the bracket enclosed
with spring washer, connecting nut and flat gasket.
(3) Screw the nuts tightly to complete the installation.

9
SEALANTER
RN ELECTRON
NICS CO., LTD
D

Fig.3-4 Mounting Instrruction for the Recording


R Conntrol Unit

3.4 Installation
n of Microp
phone Unitt SLT-18C--MU

The microphoness are designed to capture the interior communicatio


c on, public brooadcasting syystem
and the installedd equipment with audiblee and visual alarm functioons in the brridge as mucch as
posssible, and to continuouslyy record the sound
s signalss from the woorking stationns. The mounting
locaation shall meeet the following requirements:
(1) Installedd in a positioon nearby thee directing poosition of thee bridge, radaar display deevice,
chart tabbles, etc.
(2) Far awayy from other electric equiipment, or instance, the eqquipment whhich release sttrong
electrom
magnetic interrference, suchh as radar and d the radiocommmnucation eequipment
(3) Far awayy from the obbjects which maym cause meechanical dam mages to the ddevice
(4) A workinng environmeent with reliaability and con ntinuity.
(5) Easy to approach
a to replicate
r the recorder
r data and for routinne maintenannce
(6) Locatedd in a positioon from the other conneccting equipm ment in the bbridge as sho ort as
possible

10
SEALANTER
RN ELECTRON
NICS CO., LTD
D

Fig.3-5 Mounting Instrruction of the Water


W Proof Microphone Unit

Fig.33-6 Mounting Innstruction of th


he Indoor Microophone Unit

3.5 Installation
n of Powerr Supply Boox SLT-18C
C-PU

3.5.11 Selection off Mounting Location


L

The power supply shall be insstalled in the bridge. The mounting


m loccation shall m
meet the follo
owing
requuirements:
(1) Far awayy from other electric equiipment, or instance, the eqquipment whhich release sttrong
electrom
magnetic interrference, suchh as radar and
d the radiocommmnucation eequipment
(2) Far awayy from the obbjects which may
m cause meechanical dam mages to the ddevice
(3) A workinng environmeent with reliaability and conntinuity.

11
SEALANTERN ELECTRONICS CO., LTD

(4) Easy to approach to replicate the recorder data and for routine maintenance
(5) Located in a position from the other connecting equipment in the bridge as short as
possible

3.5.2 Mounting Steps

(1) Before installing the power supply unit, weld the base on the mounting location. Fix the
mounting bracket on the wall following the mounting instruction.
(2) Fix the power supply unit on the base by the spring washer, connecting nut and flat
gasket.
(3) Fix the base of the power supply unit on the mounting bracket and make the mounting
holes right to the responding holes on the bracket. Mount the nuts on the bracket enclosed
with spring washer, connecting nut and flat gasket.
(4) Screw the nuts tightly to complete the installation

Fig.3-7 Mounting Instruction of the Power Supply Unit

3.6 Installation of Data Acquisition Unit SLT-18C-DAU

3.6.1 Function of Data Acquisition Unit(DAU)


Function of Data Acquisition Unit:
1. Digital Signal(Contact) Input: D100-D123;
2. Serial Signal Input: COM1-COM4;
3. Analog Signal Input: AI00-AI07。

3.6.2 Selection of Mounting Location

12
SEALANTERN ELECTRONICS CO., LTD

The Data Acquisition Unit shall be installed in the bridge. The mounting location shall meet the
following requirements:
(1) Far away from other electric equipment, or instance, the equipment which release strong
electromagnetic interference, such as radar and the radiocommnucation equipment
(2) Far away from the objects which may cause mechanical damages to the device
(3) A working environment with reliability and continuity.
(4) Easy to approach to replicate the recorder data and for routine maintenance
(5) Located in a position from the other connecting equipment in the bridge as short as
possible

3.6.3 Mounting Steps

(1) Before installing the Data Acquisition Unit, weld the base on the mounting location. Fix
the mounting bracket on the wall following the mounting instruction.
(2) Fix the base of the Data Acquisition Unit on the mounting bracket and make the mounting
holes right to the responding holes on the bracket. Mount the nuts on the bracket enclosed
with spring washer, connecting nut and flat gasket.
(3) Screw the nuts tightly to complete the installation

Fig.3-8 Installation Drawing of DAU

13
SEALANTERN ELECTRONICS CO., LTD

3.7 Installation of Serial Port Device Junction Box

3.7.1 Selection of Mounting Location


The serial port device junction box shall be connected by the data cable,its two ends connect to the
VDR main unit and connecting device.
The mounting location shall meet the following requirements:
(1) Far away from fuel or other potential fire source
(2) Far away from the objects which may cause mechanical damages to the capsule
(3) A working environment with reliability and continuity.

Fig.3-9 Installation Drawing of Serial Port Device Junction Box

3.8 Installation of Data Input Unit SLT-18C-DIU

3.8.1 Function of Data Input Unit(DIU)

When the AI and DI quantity acquired by the system more than the channel provided by the data
acquisition unit, the data input unit could extend AI or DI.

3.8.2 Selection of Mounting Location

14
SEALANTERN ELECTRONICS CO., LTD

The Data Input Unit shall be installed in the bridge. The mounting location shall meet the
following requirements:
(1) Far away from other electric equipment, or instance, the equipment which release strong
electromagnetic interference, such as radar and the radiocommnucation equipment
(2) Far away from the objects which may cause mechanical damages to the device
(3) A working environment with reliability and continuity.
(4) Easy to approach to replicate the recorder data and for routine maintenance
(5) Located in a position from the other connecting equipment in the bridge as short as
possible

3.8.3 Mounting Steps

(1) Before installing the Data Acquisition Unit, weld the base on the mounting location. Fix
the mounting bracket on the wall following the mounting instruction.
(2) Fix the base of the Data Acquisition Unit on the mounting bracket and make the mounting
holes right to the responding holes on the bracket. Mount the nuts on the bracket enclosed
with spring washer, connecting nut and flat gasket.
(3) Screw the nuts tightly to complete the installation

15
SEALANTERN ELECTRONICS CO., LTD

Fig.3-10 Installation Drawing of Data Input Unit

3.9 Installation of Net Video Capture Unit SLT-18C-NV4

3.9.1 Function of Net Video Capture Unit


The Net Video Capture Unit capture the Radar or ECDIS picture data, and sends the data to
RCU with net.

3.9.2 Selection of Mounting Location

The Net Video Capture Unit shall be installed in the bridge. The mounting location shall meet the
following requirements:
(1) Far away from other electric equipment, or instance, the equipment which release strong
electromagnetic interference, such as radar and the radiocommnucation equipment
(2) Far away from the objects which may cause mechanical damages to the device
(3) A working environment with reliability and continuity.
(4) Easy to approach to replicate the recorder data and for routine maintenance
(5) Located in a position from the other connecting equipment in the bridge as short as

16
SEALANTERN ELECTRONICS CO., LTD

possible

3.9.3 Mounting Steps

(1) Before installing the Net Video Capture Unit, weld the base on the mounting location. Fix
the mounting bracket on the wall following the mounting instruction.
(2) Fix the base of the Net Video Capture Unit on the mounting bracket and make the
mounting holes right to the responding holes on the bracket. Mount the nuts on the
bracket enclosed with spring washer, connecting nut and flat gasket.
(3) Screw the nuts tightly to complete the installation

Fig.3-11 Installation Drawing of Net Video Capture Unit

4. System Cabling
The following involved cable type and color are subject to what our company provide.

17
SEALANTERN ELECTRONICS CO., LTD

4.1 External Connection of Recording Control Unit

Recording control unit connections include:


(1) The power supply cable connection of the recording control unit;
(2) The cable connection with the microphone unit;
(3) The cable connection with the VHF radio telephone;
(4) The cable connection between recording control unit and devices with the serial ports;
(5) The cable connection between recording control unit and PDC junction box;
(6) The cable connection between UPS serial port and recording control unit;
(7) The cable connection between recording control unit and FPDC junction box;
(8) The cable connection between playback device and recording control unit;
(9) The cable connection between recording control unit and radar video.

18
SEALANTERN ELECTRONICS CO., LTD

4.1.1 The interface diagram of the main control unit interface board

19
SEALANTERN ELECTRONICS CO., LTD

4.1.1.1 The Power Supply Interface of the Recording Control Unit(CN1)

Cable
Cable Name Cable Connection Position Signal connection
Specification

Recording Power Supply


Control Unit Box Signal
Recording
Power CN1 Power Supply Specification
3X1mm2 Control Unit
Supply Cable Box Terminal
CN1
3-wire Aviation Connection
Connector 1-3 Terminals

1 Red 1 Red +24V


2 Yellow 2 Yellow -24V

Enclosure E E

4.1.1.2 The Interface between Recording Control Unit and Microphone(CN4- CN11)

Connect the recording control unit to a microphone with a cable, and insert the microphone cable
connection head into the aviation connector for VHF telephone on the bottom board of the
recording control unit.

Cable Cable
Cable Connection Position Signal Connection
Name Specification

Recording Control Unit Signal


MIC Unit Recording MIC Unit
6-wired CN3-CN8 Specification
MIC Cable Control Connection
0.5mm2X6 7-wire aviation Connection
CN4-CN11 Terminal
Connector 1-6 Terminal
1 Blue 1 Blue MIC+
2 White 2 White MIC-
3 Black 3 Black GND
4 Brown 4 Brown SPK
5 Green 5 Green -15V
6 Yellow 6 Yellow +15V
7 N\A N\A

20
SEALANTERN ELECTRONICS CO., LTD

MIC Unit connection method is the same, referring to the following figure:

4.1.1.3 The Interface between Recording Control Unit and VHF Radio Telephone(CN12- CN14)

Connect a VHF telephone to the recording control unit with a cable, and insert the VHF
Telephone cable connection head into the aviation connector for VHF telephone on the bottom
board of the recording control unit,three VHF telephone could be connected and methods are the
same.

Cable Cable
Cable Connection Position Signal Connection
Name Specification
Recording Control VHF Radio Signal
2-wired Recording
VHF Unit CN9-CN11 Telephone VHF Radio Specification
0.5mm2 X2 Control Unit
Cable 4-wired aviation Telephone
AF and E CN12-CN14
connector 1-4

1 Red AF Red VDR+

2 White E White VDR-

4.1.1.4 The Interface between Recording Control Unit and Serial Port Device(CN16-CN21)

Cable
S/N Cable Name Cable Connection Position Signal Connection
Specification
Recording Signal
Recording
S01&S07 Control Specification
2-wired Control Unit S01/S07 S01 S07
1 Serial Port Unit
0.5mm2X2 CN12
Cable CN16
4-pin Aviation Connection 1 1 Red - RX5+

21
SEALANTERN ELECTRONICS CO., LTD

Connector1-4 Terminal 2 2White - RX5-


3 - 1 Red RX11+
4 - 2 White RX11-
Recording
Recording
Control
Control Unit S02/S08 S02 S08
Unit
S02&S08 CN13
2-wired CN17
2 Serial Port 2
0.5mm X2 1 1 Red - RX6+
Cable 4-pin Aviation
Connection 2 2Yellow - RX6-
Connector
Terminal 3 - 1 Red RX12+
1-4
4 - 2 Yellow RX12-
Recording
Recording
Control
Control Unit S03/S09 S03 S09
Unit
CN14
S03&S09 CN18
2-wired
3 Serial Port
0.5mm2X2 1 1 Red - RX7+
Cable
4-pin Aviation Connection 2 2 Yellow - RX7-
Connector 1-4 Terminal 3 - 1 Red RX13+
4 - 2 Yellow RX13-
Recording Recording
Control Unit S04/S10 Control S04 S10
S04&S10 CN15 Unit CN19
2-wired
4 Serial Port 1 1 Red RX8+
0.5mm2X2
Cable 4-pin Aviation Connection 2 2 Yellow RX8-
Connector 1-4 Terminal 3 1 Red RX14+
4 2 Yellow RX14-
Recording Recording
Control Unit S05/S11 Control S05 S11
CN16 Unit CN20
S05&S11
2-wired
5 Serial Port 1 1 Red - RX9+
0.5mm2X2 4-pin Aviation
Cable Connection 2 2 Yellow - RX9-
Connector
Terminal 3 - 1 Red RX15+
1-4
4 - 2 Yellow RX15-
Recording
Recording
Control
Control Unit S06/S12 S06 S12
Unit
S06&S12 CN17
2-wired CN21
6 Serial Port 2
0.5mm X2 1 1 Red - RX10+
Cable 4-pin Aviation
Connection 2 2 Yellow - RX10-
Connector
Terminal 3 - 1 Red RX16+
1-4
4 - 2 Yellow RX16-

22
SEALANTERN ELECTRONICS CO., LTD

4.1.1.5 The Interface between Recording Control Unit and PDC(CN2,CN22)

The PDC is connected to the recording control unit with two cables: One is the power supply
cable; and another is the data cable. The length should not be more than 30m. Connection method
is as follows:

Cable
Cable Cable Connection
S/N Specificat Signal Connection
Name Position Signal
ion
Specificati
Recording Recording
PDC on
Control PDC Control
PDC Unit CN2 Unit CN2
3-wired
1 Power Supply 3-pin 1 Red J1-1 Red +24VDC
1mm2X3
Cable Aviation Connection J1-2Yello
2 Yellow -24VDC
Connector Terminal w
1-3 Enclosure J1-3E SHIELD
Recording Recording
PDC
4-wired Control PDC Control
0.5mm2X Unit CN24 Unit CN22
PDC
2X2 1 Red J4-1 Red TX+
2 Ethernet 4-pin
2 Black J4-2 Black TX-
Cable Aviation Connection
3 Green J4-3Green RX+
Connector Terminal
4 White J4-4White RX-
1-4
Enclosure E SHIELD

(CN15)
4.1.1.6 The Interface between Recording Control Unit and UPS Serial Communication Port

Cable Cable
Cable Connection Position Signal Connection
Name Specification Signal
Recording Power Recording Specificat
Power Supply
Control Unit Supply Control Unit ion
Box
4-wired CN15 Box CN15
232 Signal 2
0.5mm X2X 4-pin 1 Red 4 Red TR
Cable
2 Aviation Connection 2 Black 3 Black RE
Connector Terminal 3 Green 5 Green SG
1-3 4 White - -

4.1.1.7 The Interface Between Recording Control Unit and Data Acqusition Unit(CN23)

Cable Cable
Cable Connection Position Signal Connection
Name Specification Signal
Playback 4-wired Recording Playback Recording Playback Device Specification
Equipment +5 Net Cable Control Device&Data Control Unit RJ-45

23
SEALANTERN ELECTRONICS CO., LTD

Cable Unit CN23 Acqusition Unit CN23


4-pin 1White orange 1White orange TX+
Aviation Connection 2 Orange 2Orange TX-
Connector Terminal 3White Green 3White Green RX+
1-4 4Green 6 Green RX-

4.1.1.8 The Interface Between Recording Control Unit and Playback Device(CN24)

Cable Cable Cable Connection


Signal Connection
Name Specification Position
Signal
Recording
Playback Recording Control Playback Specification
Control
Device Unit CN24 Device RJ-45
Unit CN24
Playback
4-wired 1White orange 1White
Equipment 4-pin TX+
+5 Net Cable orange
Cable Aviation Connection
2 Orange 2Orange TX-
Connector Terminal
3White Green 3White Green RX+
1-4
4Green 6 Green RX-

4.1.1.9 The Interface Between Recording Control Unit and Alarm Panel(CN28)

Cable Cable
Cable Connection Position Signal Connection
Name Specification
Recording Signal
Alarm Recording
Alarm Panel 6-wired Control Unit Alarm Panel Specification
2 Panel Control
Cable 0.5mm X6 CN22 DB9-F
Unit CN22
DB9(Female) DB9(Female)

2 2 RX

3 3 TX

5 5 GND

6 6 24V+

8 8 24V-

4.1.1.10 The Interface Between Recording Control Unit and Radar Video(CN23,CN24)

Cable Cable
Cable Connection Position Signal Connection
Name Specification
Recording
Recording Signal
Control Unit Radar
Radar Video VGA Standard Control Unit Specification
CN25,CN26,C Device Radar Device
Cable Cable CN25,CN26,C
N27
N27
DB15(Female)

24
SEALANTERN ELECTRONICS CO., LTD

1 R R
2 G G
3 B B
6 GNDR GNDR
7 GNDG GNDG
8 GNDB GNDB
10 GND GND
13 HS HS
14 VS VS

4.1.1.11 The Interface Between Recording Control Unit and FPDC(CN3)

Cable Cable
Cable Connection Position Signal Connection
Name Specification
Recording
Signal
Control Unit FPDC
6-wired Recording FPDC Specification
FPDC Cable 2
CN3
1mm X6 Control Unit CN3 J30
7-pin Aviation
J30
Connector 1-7
1 8 TX+
2 9 TX-
3 10 RX+
4 11 RX-
5 5 24V-
6 6 24V+

4.2 Internal Connection of the Recording Control Unit

4.2.1 Serial Port Cable Connection between Mainframe and Serial Port Board

Cable Name Mainframe Serial Interface Board Signal Connection Signal


Serial Port Cable HD62 male HD62 male HD62 male HD62 male Specification
1 1 TX1+
2 2 TX1-
3 3 TX2+
4 4 TX2-
5 5 TX3+
6 6 TX3-
7 7 TX4+
8 8 TX4-
9 9 DATA1+
10 10 X
11 11 DATA2+

25
SEALANTERN ELECTRONICS CO., LTD

12 12 DATA3+
13 13 X
14 14 DATA4+
15 15 DATA5+
16 16 X
17 17 DATA6+
18 18 DATA7+
19 19 X
20 20 DATA8+
21 21 X
22 22 X
23 23 422_GND1
24 24 X
25 25 422_GND2
26 26 X
27 27 422_GND3
28 28 X
29 29 422_GND4
30 30 X
31 31 485_GND1
32 32 485_GND2
33 33 X
34 34 485_GND3
35 35 485_GND4
36 36 X
37 37 485_GND5
38 38 485_GND6
39 39 X
40 40 485_GND7
41 41 485_GND8
42 42 X
43 43 RX1+
44 44 RX1-
45 45 RX2+
46 46 RX2-
47 47 RX3+
48 48 RX3-
49 49 RX4+
50 50 RX4-
51 51 DATA1-
52 52 X
53 53 DATA2-
54 54 DATA3-

26
SEALANTERN ELECTRONICS CO., LTD

55 55 X
56 56 DATA4-
57 57 DATA5-
58 58 X
59 59 DATA6-
60 60 DATA7-
61 61 X
62 62 DATA8-

4.2.2 Audio Cable Connection between Mainframe and Mixer

Cable Name Mainframe Mixer Signal Connection


Length
Audio Cable DB25 Signal Specification
DB25 female DB25 male DB25 female (mm)
female
1 1 MIC IN 0
2 2 LIN IN R0
3 3 LIN OUT R0
4 4 MIC IN 1
5 5 LIN IN R1
6 6 LIN OUT R1
7 7 MIC IN 2
8 8 LIN IN R2
9 9 LIN OUT R2
10 10 MIC IN 3
11 11 LIN IN R3
12 12 LIN OUT R3
13 13 - 300
14 14 LIN IN L0
15 15 LIN OUT L0
16 16 GND0
17 17 LIN IN L1
18 18 LIN OUT L1
19 19 GND1
20 20 LIN IN L2
21 21 LIN OUT L2
22 22 GND2
23 23 LIN IN L3
24 24 LIN OUT L3
25 25 GND3

27
SEALANTERN ELECTRONICS CO., LTD

4.2.3 Audio Test Cable Connection between Mainframe and Mixer

Cable Name Mainfrme Mixer Signal Connection Signal Length


AudioTestCable DB15 female DB15 male DB15 female DB15 male Specification (mm)
1 1 D0-0
2 2 D0-2
3 3 D0-4
4 4 D0-6
5 5 D0-8
6 6 D0-10
7 7 D0GND
8 8 D0GND 300
9 9 D0-1
10 10 D0-3
11 11 D0-5
12 12 D0-7
13 13 D0-9
14 14 D0-11
15 15 PCOM

4.2.4 UPS Communication Cable Connection between Mainframe and Serial Interface Board

Serial Interface
Cable Name Mainframe Signal Connection
Board
Signal Length
UPS Serial interface
Mainframe Specification (mm)
Communication DB9 female DB9 male Board
DB9 female
Cable DB9 male
1 1 -

3 ○
2 RX

2 ○
3 TX
4 4 -

5 ○
5 GND 700
6 6 -
7 7 -
8 8 -
9 9 -

4.2.5 Cable Connection between Mainframe and Alarm Panel

28
SEALANTERN ELECTRONICS CO., LTD

Cable Name Mainframe Alarm Panel Signal Connection


Signal Length
Alarm Panel Mainframe Alarm Panel
DB9 female DB9 female Specification (mm)
Cable DB9 female DB9 female
1 1 -

2 ○
2 RX

3 ○
3 TX 600
4 4 -

5 ○
5 GND
6 6 - 0.3mm2
7 ○
7 -24 Extracted
800
8 ○
8 +24

9 9 -

4.2.6 Standard VGA Video Cable Connection between Mainframe and Serial Interface Board

Cable
Mainframe Serial Interface Board Signal Connection
Name
Serial Signal Length
Mainframe Interface Specification (mm)
Video Cable HD15female HD15 male
HD15female Board
HD15 male

1 ○
1 R

2 ○
2 G

3 ○
3 B
4 4
5 5

6 ○
6 GNDR

7 ○
7 GNDG
750

8 ○
8 GNDB
9 9

10 ○
10 GND
11 11
12 12

13 ○
13 HS

14 ○
14 VS
15 15

4.2.7 Microphone Cable Connection between Mixer and Microphone Interface Board

Cable Name Microphone Mixer Signal Connection Signal Length

29
SEALANTERN ELECTRONICS CO., LTD

Interface Specification (mm)


Board
Microphone
DB25 male DB25 male
Cable
1 1 MIC1+
2 2 SPK1
3 3 MIC2-
4 4 MIC3+
5 5 SPK3
6 6 MIC4-
7 7 MIC5+
8 8 SPK5
9 9 MIC6-
10 10 MIC7+
11 11 SPK7
12 12 MIC8-
13 13 VHF1
14 14 VHF3
15 15
16 16
17 17
18 18 GND
19 19 -12V 300
20 20 MIC1-
21 21 MIC2+
22 22 SPK2
23 23 MIC3-
24 24 MIC4+
25 25 SPK4
26 26 MIC5-
27 27 MIC6+
28 28 SPK6
29 29 MIC7-
30 30 MIC8+
31 31 SPK8
32 32 VHF2
33 33
34 34
35 35
36 36 GND
37 37 +12V

30
SEALANTERN ELECTRONICS CO., LTD

5. Alarm Panel

5.1 Alarm Panel Functions Introduction

Check the function buttons and the combination function buttons in the table below:

Item Button Function Operation instruction


If alarm sound and flicker appear simultaneously
Page Up + after clicking the test button,it indicates the alarm
1 Alarm panel test
Page Down panel works normally; if no response appears
after clicking, switch off the VDR and restart it
Page up to check
2 Page Up
alarm records.
Page down to
3 Page Down check alarm
records.
4 Page Left Obumbrate
5 Page Right brighten
Alarm sound
6 SOUND ACK
acknowledgment
7 FLICKER ACK Alarm flicker

31
SEALANTERN ELECTRONICS CO., LTD

acknowledgment

5.2 Error Code List of the Alarm Panel

Power on the VDR, the alarm panel start operating in one minute. If alarm occurs with the LED
indicator flickering and sound & light alarming (except RECORDING), it means fault occurred as
below:
Alarm
code indicator Meaning Inspection
signification
OK normal - normal Time displaying changes
PDC can not
M01 PDC error PDC Check PDC Ethernet or the power
record data
FPDC can not
M02 FPDC error PDC Check FPDC Ethernet or the power
record data
UPS main No AC power
P00 Power Check AC110/220V input
power error supply
UPS
No DC power
P01 emergency Power Check DC24V input
supply
power error
S01 Serial port 1~ Device linked to the corresponding
~ Serial port 20 COM Serial signal lost serial port is power on and the
S20 error connection is normal
Radar 1 signal Radar 1 is power on and the
V01 Video 1 error VIDEO
lost connection is normal
Rada r2 signal Radar 2 is power on and the
V02 Video 2 error VIDEO
lost connection is normal
ECDIS 1 signal ECDIS1 is power on and the
V03 Video 3 error VIDEO
lost connection is normal
ECDIS 2 signal ECDIS2 is power on and the
V03 Video 3 error VIDEO
lost connection is normal
A01 Microphone1
Microphone Check the corresponding
~ ~microphone AUDIO
signal lost microphone and the connection
A06 6 error
D01 Corresponding
Switch interface Check the state of the corresponding
~ switch interface COM
signal lost switch interface
D64 error
Corresponding Analogue
AI01~ Check the state of the corresponding
analogue port COM interface signal
AI16 analogue interface
error lost

32
SEALANTERN ELECTRONICS CO., LTD

6. System Connection Drawings

6.1 The Diagram of Power Supply Unit

33
SEALANTERN ELECTRONICS CO., LTD

34
SEALANTERN ELECTRONICS CO., LTD

6.2 System Maintenance Device Connection Drawing

35
SEALANTERN ELECTRONICS CO., LTD

6.3 Internal Cable Connection of Recording Control Unit

36
SEALANTERN ELECTRONICS CO., LTD

6.4 External Power Connection Drawing Of Recording Control Unit

37
SEALANTERN ELECTRONICS CO., LTD

6.5 Internal Cable Connection of Data Acquisition Unit

38
SEALANTERN ELECTRONICS CO., LTD

6.6 External Cable Connection of Data Acquisition Unit

39
SEALANTERN ELECTRONICS CO., LTD

6.7 PDC Connection Drawing

40
SEALANTERN ELECTRONICS CO., LTD

6.8 FPDC Connection Drawing

41
SEALANTERN ELECTRONICS CO., LTD

6.9 Net Video Capture Unit Connect Drawing

42
SEALANTERN ELECTRONICS CO., LTD

6.10 Connection Drawing For Junction Box for Devices with Serial Port

43
SEALANTERN ELECTRONICS CO., LTD

7. Data Recording and Data Comprising

7.1 Data Recording

The signals of sensors,VHF,microphones and the radars are collected by the main
control unit and the data acquisition unit. These signals are stored in the final record
medium of the PDC. The system configuration file and the radar image configuration
file are also recorded in the final record medium.

7.1.1 Real time of the data acquisition


Resolutions of acquisition time for all data are 0.01s and the data be saved to the main
computer and the PDC in real time.
1. Serial data of the sensors be collected and saved to the main computer in real time;
2. Analogue interfaces and switch interfaces data will be saved to the main computer
while they are acquired.
3. The acquired microphone audio data are recorded to a audio-file-format file in the
PDC whenever the audio signal is captured during 1 minute.
4. The acquired radio communication data are recorded as one file to the PDC
whenever the signal is captured during 1 minute.
5. The radar display image is captured in every 15 seconds and 4 images every minute,
the data is saved to the PDC after be compressed by the main computer .

7.1.2 Storage requirements for data recording

The capacity of the fixed PDC and the float-free PDC are all 32GB, it it can record
the data continuously for 48 hours. The capacity of the long-term storage medium is
512GB, it can record the data continuously for 30 days. Data be recorded must meet
the following requirements:
1. For serial port signal of the sensors,analogue data and switch data, up to 21
sentences with 82 characters in maximum length, per second.
2. Data recording of the microphone audio is captured by 3 radio channels, one of
which can connect 3 microphones. Audio data file size compressed is up to 252kB,
per minute per channel.
3. Data recording of the radio communication is only captured by one radio channel,
which can connect 3 VHF radio channels. Audio data file size compressed is up to
252kB, per minute.
4. Radar display image data is collected in every 15 seconds, up to 300kB per frame.

7.2 Data comprising

The recorded data are saved simultaneously to the main computer and the PDC, and the data can
be downloaded to the personal computer. The data is constructed with the data folder named with
the minute, the system configuration file and the radar image configuration file. Each folder

44
SEALANTERN ELECTRONICS CO., LTD

contains audio, sentences and radar images recorded during that minute.

7.2.1 Fold structure

File name Data contents File type


Initial and configuration file, contains vessel
sys.ini ini
information and product installation configuration
Initial and configuration file used for radar image
setup.cfg cfg
collection
Serial port sentences for communication &
Mk.txt
Navigation devices, contains IEC61162 format txt
(k=01,02,03…20)
data
DI.txt Switch data, convert to IEC61162 format data txt
AI.txt Analogue data, convert to IEC61162 format data txt
Collected audio data, contains microphone and
n.itu(n=1~4) G.722
VHF radio
year-mon-day-hou
Radar display image data JPG
r-min-sec.jpg

7.2.2 Sensor Data


After sensor data be acquired, it is saved to the “data” folder as a txt format file named
“Mk.txt”(k=01,02,03...20) automatically. “k” here indicates the 16 RS422/485 serial port of the
corresponding device(01-04 are RS232 serial port used for the device internal connection) and
port 17-20 are connected with the 4 RS422/485 serial ports from the data acquisition unit. Its
sentence meets the IEC61162 standard. txt format file can be browsed by using Windows
WordPad.

7.2.3 Switch data and Analogue data


After switch data and analogue data be acquired, it is saved to the “data” folder as a txt format file
named “ai” and “di” automatically.VDR convert the acquired switch and analogue data to
IEC61162 format sentences and save it into the folder. txt format file can be browsed by using
Windows WordPad.

7.2.4 Microphone and VHF audio data

The file is automatically assigned a unique file name according to the audio source channel. There
are 4 audio channels:

- 1.itu ; This channel is used for microphone No.1 , No.2 and No.3 sound mixing;
- 2.itu ; This channel is used for microphone No.4 ,No.5 and No.6 sound mixing;
- 3.itu ; This channel is used for microphone No.7 and No.8 sound mixing;
- 4.itu ; This channel is used for VHF radio input No.1-No.3 sound mixing.

45
SEALANTERN ELECTRONICS CO., LTD

The content of “.itu” file adopts compressed G.722 format audio. The file can be played using
playback software or audio decompression software.

7.2.5 Radio/ECDIS image data

2 channels of Radar/ECDIS image data can be acquired, the file is named by time accurate
to the second. The last digit indicates the radar number, 1 for the first one, 2 for the second one
and 3 for the second one. One image is saved for each radar for every 15 seconds. The format of
the file name is: year-month-day-hour-min-sec-n.jpg, for example:
2006-01-25-09-55-14-1.jpg.The data format of this file is JPG. The file can be played by using
playback software or audio decompression software.

7.2.6 Configuration Information Data

While the other data are dynamic data and they are continuously saved to the PDC & HDD, the
system configuration information is static data that is set after installation. The file is
automatically given the name of “sys.ini”,”setup1.cfg” and ”setup2.cfg”. The system
configuration file contains information of vessel and devices installing configuration. The main
control software acquires the radar image according to the standard that defined in the radar image
acquiring configuration file, where “sys.ini”,”setup1.cfg” and ”setup2.cfg” are generated by radar
configuration tool “demo.exe” directly.

7.2.7 Configuration file “sys.ini”

VDR configuration file “sys.ini” is stored under the current path of the VDR main control
software (name as VDR.exe). Its format complies with the standard Windows configuration file
format:
[Section name 1]
Key word=value
[Section name 2]
Key word=value

item name signification


Section name. The system information is saved in
1 [sys]
this section.
2 PDC=\\PDC\data storage path of the data in the PDC
3 lrecord=d:\data storage path of the data in the main control unit
4 user="admin" user name of the PDC
5 password="admin" Password of the PDC
number of the serial port which the UPS connects to.
6 ups=1 Here “1” indicates the UPS connects to the first
serial port.
configuration information of the serial port the UPS
7 ups_set=2400,n,8,1
connects to. Here “2400,n,8,1” indicates the baud

46
SEALANTERN ELECTRONICS CO., LTD

rate is 2400 bps, no verifying bit, 8 data bits as well


as1 stop bit.
number of serial port which the alarm panel
8 a_panel=2 connects to. Here “2” indicates the alarm panel
connects to the system via the second serial port.
configuration information of the serial port which
alarm panel connects to. Here “9600,n,8,1” indicates
9 a_set=9600,n,8,1
the baud rate is 9600 bps, no verifying bit, 8 data bits
as well as 1 stop bit.
video card port number and its enabled status . “1”
10 Image0/Image1=
indicates “enable”, “0” indicates “disable”.
11 shipname= Name of the ship
12 approval= The approval classification society
13 imoid= IMO ID
14 imoname= Register name in IMO
15 softver=vdr 1.0 VDR software version
16 installname= Name of the engineer installed the VDR
17 installcompany= Name of the company that the engineer serves at
18 installdate= Installation date of the VDR
19 voice_test=3 Frequency choice of the microphone self-test
Section name. This section includes
20 [com1] the configuration information of the first
serial port(except the RS232 serial ports )
Number of the serial port used in the system, “5”
21 comid=5
here indicates the serial port 5
Configuration information of the serial port,baud rate
22 comset=4800,n,8,1
is 4800bps,no verifying bit and 1 stop bit
Key word of the device that the serial port connects
23 id= to,it is an IEC61162 standard sentence of the serial
port record
Time delay of the alarm,”30”here indicates 30
24 a_time=30
seconds
Enabled status of the serial port, “1” indicates
25 bln_use=1
enable,”0” disable
Section name, configuration information of the first
26 [voice1]
audio card
Enabled status of the audio card, “1” indicates
27 blnuse=0
enable,”0” disable
name of the device that the first channel of the first
audio card connects to, it can be MIC1-MIC9 and
28 line1=MIC1
VHF1-VHF3. If a MIC or a VHF telephone is not
connected, “none” should be selected.

47
SEALANTERN ELECTRONICS CO., LTD

name of the device that the second channel of the


first audio card connects to, it can be MIC1-MIC9
29 line2=MIC2
and VHF1-VHF3. If a MIC or a VHF telephone is not
connected, “none” should be selected.
name of the device that the third channel of the first
audio card connects to, it can be MIC1-MIC9 and
30 line3=none
VHF1-VHF3. If a MIC or a VHF telephone is not
connected, “none” should be selected.

48
SEALANTERN ELECTRONICS CO., LTD

8. System Software Construction

8.1 Remote desktop connection software

The name of the remote desktop connection software is“REMOTE DESKTOP CONNECTION”.
By running this software, operator can modify the software setting of VDR control box via
notebook PC. Modifiable items as following:
a) Monitor the VDR
b) Set the software parameters
c) Set the Industry PC
d) Examine the condition of data inside PDC
Operational method as following::Doubly click the software, dialog box interface will spring out
as following:

Click“OPTIONS”,and following interface will spring out:

49
SEALANTERN ELECTRONICS CO., LTD

In the “General” interface, input the IP address of the SVDR control box “192.168.0.100” after
“COMPUTER”. Input "administrator” for ”USER NAME”.

Click “LOCAL RECOURSES:, and following operational interface will spring out:

50
SEALANTERN ELECTRONICS CO., LTD

Choose “LEAVE AT REMOTE COMPUTER” for the dialog box after “REMOTE COMPUTER
SOUND”.

Keep choice of other equipments as default values, which can be set as user’s requirements.

After modification of above settings, do the remote connection. Click “CONNECT” to get into the
WINDOWS system operational platform of the VDR control box.

When exit the remote login,move the mouse up to the screen center, click "X" to return to the
personal computer desktop.

8.2 Main Controlling Software Instruction

8.2.1 Software Functions

The functions of the main controlling software as follows:

1) The function of data: including VHF ,radar video, serial statement,analogue and switching
interface ,data acquisition and compression ,save .
2) Power management function: real-time monitor and indicate the running status of the
power supply .
3)Alarm function: abnormal operation will the cause audible and visual alarm to inform the
operator in text, sound and light ways.

51
SEALANTERN ELECTRONICS CO., LTD

4)Data indication function: indicate all the organizing data on the vessel to the operator.
5) PDC status monitoring function: monitor the running status of PDC in real time. Once
abnormal running occurs, the visual and audible alarm will be active and inform the
operator.
6) Monitoring function: a watchdog is included in the entire system. When the programme
breaks off or exits, the programme will re-start soon automatically.
7) Programme re-start function: the system can re-start the operation in case of abnormal
running or abnormal exit of the main controlling software.
8) Programme self-inspection function: when programme starts or runs, all the input device
connected to the system will be inspected by the programme at a certain interval and
recorded by text.
8.2.2 Start of Main Controlling Software
Referring to fig.8-1, dblclicking the iron “VDR.EXE” on the desktop, the software will start.
Fig.8-2 is the main screen of the software.

Dblclicking the iron,


the software will start.

Fig.8-1 Startup of the Software

52
SEALANTERN ELECTRONICS CO., LTD

Fig.8-2 The main screen of the software

8.2.3 Software Screens Introduction

The operation screen includes 3 operation parts: “Tool Bar”, “Status Bar” and “Display Bar”.

1) Tool Bar: click the buttons separately; the corresponding screen will appear as follows:
b) GENERAL: All the status and alarm indication of the equipment connected to VDR
c) IMAGE : Video acquisition and display screen
d) VOICE: Audio wave display and test screen
e) COMM: Serial port data display and management screen
f) POWER: Power management screen
g) ALARM: Alarm list screen
h) EXIT: Exit from the control software
i) MINIMIZE: Minimize this software
j) DISPLAY DATA: Show IEC61162-format data of serial port GPS,COMPASS and so
on
k) NOT DISPLAY DATA: Stop to show IEC61162-format data of serial port GPS,
COMPASS and so on
2) Status Bar:
a) RUN: When the programme is running, the indicator light becomes green and flickers;
b) LINK: When the programme is communicating with PDC correctly, the indicator light
become green and flickers; otherwise, it will become red and flickers.
c) ALARM: If no alarm happens, the indicator light will become green and flickers;
otherwise it will become yellow and flickers.
d) DAU: If no alarm happens, the indicator light will become green and flickers;
otherwise it will become red and flickers.

53
SEALANTERN ELECTRONICS CO., LTD

3) Display Bar: the display contents will be differed by different screens. Each screen will be
introduced as follows.

8.2.4 Main Screen

On clicking the button “GENERAL” on the tool bar of the software, the main screen will appear,
“Green” indicator means this model is in use and working correctly; “Red” indicator means this
model is in use but working abnormally; “Gray” indicator means this model is not in use

1) Eventlog: indicate the status of the data acquisition and storage, inluding the serial port
data, analogue and switching data,video data and audio data.
2) Status Show: running status indication of acquisition and management model in the VDR
system,includes:
a)POWER: Power management model status;
b)IMAGE: Radar Video acquisition model status;
c)PDC: Ethernet management model status;
d) SHOW: Radar image acqusition port status
3)Status Show:The RS422/485 serial port start and status.
4)Voice:The Microphone start and status.
5)AI:The analogue start and status.
6)DI;The switching start and status.

8.2.5 Audio Display Screen

On clicking the button “Voice” on the tool bar, the audio acquisition screen will appear, referring
to fig.8-4. This screen includes two configuration parts as follows: voice description and voice
channel & test.

1) Voice Description
In this part, the parameters of all the audio cards and the corresponding microphone
number which is connected to the audio card are listed. If no microphone is connected,
“none” will be displayed.
2) Voice Channel & Test
In this part, the figure is displayed as the wave graph mixed with 3-microphone input
signals. If a microphone is connected to the system, the corresponding indicator will
become “Green”, and the corresponding “Test” button will be “Enable”; otherwise, the
corresponding indicator will become “Gray”, and the corresponding “Test” button will be
“Disabled”.

On clicking the button “Test” separately, every microphone can be tested.

54
SEALANTERN ELECTRONICS CO., LTD

Fig.8-4 Audio Acquisition Screen

8.2.6 Serial Port Data Display and Management Screen

Clicking the button “Comm” on the tool bar, the serial port data display and management screen
will appear, referring to fig.8-5. This screen includes two configuration parts as follows: data
display area and data management area.

1) Data Display Area


In this part, the data acquired by all the serial ports are detailed listed; the data format
complies with the requirements of IEC61162.
2) Data Management Area
In this part, the configuration information of all the connected serial ports is listed in detail
as follows:
a) ID Identification number.
b) Name The name of the device with serial port, meanings referring to Table 5.2.
c) Device The key word of the device output signal, in according with IEC61162.
d) Port The corresponding serial port number.
e) Setting Communication protocol, including baud rate, verifying bit, data bit and stop
bit.
f) Time The start time

55
SEALANTERN ELECTRONICS CO., LTD

Fig.8-5 Serial Port Data Acquisition Screen

8.2.7 Power Management Screen

Clicking the button “Power” on the tool bar, the power management screen will appear, referring
to fig.8-6. When the main power of the ship provide power to SVDR normally, “MAIN POWER
STATUS”shows as“NORMAL”,and shows as“ALARM”when turning into abnormal condition;
when the SVDR is powered by battery inside the power box,“Emergency Power Status”shows
as “NORMAL”,and shows as“ALARM”when turning into abnormal condition

Fig.8-6 Power Management Screen


8.2.9 Alarm List Screen

The detailed list indicates all the names of the equipment which alarm from the running of the
VDR system, including the alarm appearing time and the alarm disappearing time, referring to
Fig.8-7, including:

56
SEALANTERN ELECTRONICS CO., LTD

1) ID Identification
2) Time Alarm appearing time and disappearing time
3) Description The number of the port which errors
4) Status The alarm status

Fig.8-7Alarm List

8.2.10 Data Storage Format

The data is saved in the path designated in advance, generally in the “data” folder of certain root
directory, such as path “d:\data”. In the “data” folder, the data is organized again in a sub-folder
per minute, named after the time. For example, the data at 9:55 on January 25, 2006 is saved in the
relative path “\data\2006-01-25-09-55”, all the data acquired in this minute included. A folder will
be created every minute. The total folder quantity in 12 hours is “12x60=720”, the data will
refresh after the record time exceeds 12 hours, but the latest data in 12 hours will be always kept.
Please refer to Fig.8-8.

57
SEALANTERN ELECTRONICS CO., LTD

Fig.8-8 Data Format

Every folder consists of the compressed images of radar, the serial port data and the compressed
audio data file; the quantity is according to the configuration file, referring to Fig.8-9. The format
as follows:

Fig.8-9 File Configuration

1) Serial port Data: According to the sequence when devices with serial port is added, from
“1” to “n”, the data acquired by the “K” serial port is saved in the file “Mk.txt”, for
example, the data acquired by 4th serial port at 9:55 on January 25, 2006 is saved in the
folder “\data\2006-01-25-09-55\M04.txt”. The format inside is that one message forms one

58
SEALANTERN ELECTRONICS CO., LTD

line, and the time is added in front of the message, with the accuracy of 1 second. For
example, “2006-01-25-09-55-30 message data information”, the quantity of the data files
depends on the quantity of the serial ports.
2) Audio Data: The signals of 3 microphones are mixed by the mixer and connected to the
input channel forming an audio file in the system with the unit of “channel” inside. The
audio data at first channel is firstly saved in the file”1.wav”, and then forms a new file
named”1.itu”, the original file will be deleted automatically. The quantity of the audio data
files depends on the quantity of application audio channels.
3) Radar Data: A radar image will be acquired at certain interval, and saved in the form of
picture after compressed. For example the radar data acquired at 9:55 on January 25, 2006
is saved in the file “2006-01-25-09-55-30.jpg”. According to the interval designated in
advance, the quantity of radar data files in the data folder is different. For example, if the
image acquisition interval is changed to 15 seconds, the quantity of radar data file will be 4
in the folder.

All the data above is saved in the storage memory of the recording control unit, as well as backed
up in the PDC and FPDC. All the latest data in 48 hours will be saved, while the data at excess of
48 hours will be deleted automatically, and 720 hours data will be saved in the long-term storage
medium.

8.3 Configurational Software Instruction

8.3.1 Startup of the Configurational Software

Dblclick “VDRSETTING.EXE” on the desktop of VDR mainframe as shown in fig. 8-10. Startup
the VDR configrational software as shown in fig. 8-11.

Dclick this icon to startup


the VDR configrational
software.

59
SEALANTERN ELECTRONICS CO., LTD

Fig. 8-10 Startup of Configrational software

Fig. 8-11 Main Menu of Configrational Software

8.3.2 Data Configuration

The setting of VDR system software configuration will affect the running and recording of the
main controlling software, so no mistake is allowed during the configuration. 5 parts are included
as follows:
1) Read and save configurated data
2) General data configuration
3) Image capture configuration
4) Audio acquisition configuration
5) Serial port data configuration
6) The switch and analogue of configuration data

The item 1 to 5 above will be introduced respectively in next chapter.

8.3.2.1 Read,Save and Apply of the Configuration Data

The uploading of the configuration data: On clicking the button “READ”, the “SYS.ini” data in
the system can be uploaded to the software and displayed. The user can modify it according to the
real situation of the vessel. The uploading path is default as the installation path of the software.

The downloading of the configuration data: On clicking the button “APPLY”, a dialogue box will

60
SEALANTERN ELECTRONICS CO., LTD

appear, referring to fig.8-12. User should input the right user name and password, and click the
button “OK”, and then, the configuration of the system can be modified or downloaded. The
modified and downloaded data is saved to the file “SYS.ini” in the mainframe of the VDR and the
final recording medium in the PDC. The ex-factory default user name and password are “slt” .

Click the button ”Resume” to resume the the exfactory fault setting.
Click the button “CLOSE” to finish the setting and quit the “VDRSETTING” software.

Fig.8-12 Password Dialogue Box

8.3.2.2 General Data Configuration

On clicking the button “GENERAL”, the general data configuration screen will appear, referring
to fig.8-13. The general data configuration contents are as follows:
1)NAME: Ship’s name;
2)TYPE APROVAL: type approval classification
3)IMO VESSEL ID: IMO vessel identification ID
4)IMO VESSEL NAME: IMO registered vessel name
5)SOFTWARE VERSION: the version of the main controlling software
6)INSTALL CONFIG.: engineer’s name
7)MANUFACTORY : the manufacturer of VDR
8)TIME: the installation time
9)ALARM PANEL: the serial port no. of the alarm panel connecting to the system
10)UPS CONNECT TO: the serial port no. of the UPS connecting to the system
11)LOCAL RECORD FOLDER: setting of the local storage folder
12)REMOTE RECORD FOLDER: setting of remote storage folder
13)AUTO ADJUST: automatic modification of WINDOWS time to UTC time;
14)MANUL ADJUST: manual modification of WINDOWS time to UTC time。

61
SEALANTERN ELECTRONICS CO., LTD

Fig8-13 General Data Configuration Screen

8.3.2.3 Image Capture Configuration

62
SEALANTERN ELECTRONICS CO., LTD

Fig.8-14 Video Image Configuration Screen

On clicking the button “IMAGE”, the image capture screen will appear, referring to Fig.8-14.
Image capture configuration includes:
1)IMAGE 1:in use;off use, indicate if the image grabber card is using
2)IMAGE 2: The second line radar video signal.
3) Image Set: Input radar image, has reached the best effect of acquisition
4) Audio Card Type:choose system audio card type, please keep the factory Settings.

when a radar video signal entering, click on the Image Set out radar Image configuration software,
as shown in fig 8-15.(You also can click the “SetDemo.exe” to run the configuration software )

fig8-15 Radar Image Configurated Software Screen

Specific operation as follows:

1. Select the channel you want to configure in "channel", "1"is the first radar, "2" is for the
second radar.
In the "Resolution", select the appropriate resolution. Write the refresh rate in the
"Refresh" , and fill in nothing in "Mode" . You will find the IP address on the PCBA of Net
Video Capture Unit, and Fill it in "IP" .
2. Click "Open", "Config", "Capture" button. It will show the collected image corresponding
to the left, in the "channel", "Time", "Resolution", the display of captured images the appropriate
information, if capture the image successfully.

63
SEALANTERN ELECTRONICS CO., LTD

VDR support input signal as following:


Resolution Refresh Rate Horizontal Frequency Pixel Frequency
640x350PIXEL 85Hz 37.9kHz 31.500MHz
640x400PIXEL 85Hz 37.9kHz 31.500MHz
720x400PIXEL 85Hz 37.9kHz 35.500MHz
60Hz 31.5kHz 25.175MHz
72Hz 37.9kHz 31.500MHz
640x480PIXEL
75Hz 37.5kHz 31.500MHz
85Hz 43.3kHz 36.000MHz
56Hz 31.5kHz 36.000MHz
60Hz 37.9kHz 40.000MHz
800x600PIXEL 72Hz 48.1kHz 50.000MHz
75Hz 46.9kHz 49.500MHz
85Hz 57.7kHz 56.250MHz
60Hz 48.4kHz 65.000MHz
70Hz 56.5kHz 75.000MHz
1024x768PIXEL
75Hz 60.0kHz 78.750MHz
85Hz 68.7kHz 94.500MHz
1152x864PIXEL 75Hz 37.9kHz 108.000MHz
1280x960PIXEL 60Hz 37.9kHz 108.000MHz
60Hz 64.0kHz 108.000MHz
1280x1024PIXEL
75Hz 80.0kHz 135.000MHz
1600 x1200PIXEL 60Hz
1920 x1200PIXEL 60Hz

8.3.2.4 Audio Channel Configuration

On clicking the button “VOICE”, the audio channel configuration screen will appear, referring to
fig.8-16. The audio channel configuration includes:

64
SEALANTERN ELECTRONICS CO., LTD

Fig.8-16 Audio Channel Configuration

1)1CH,2CH,3CH,4CH: channel number of the audio acquisition device


2)NOT CONNECT: unconnected microphone or VHF radio telephone
3)MIC1 ~ MIC9: series number of the microphone
4)VHF1 ~ VHF3: series number of the VHF radio telephone
5) Position: installed location of the microphone

Operation method: select the corresponding microphone channel “CH1” to “CH4”, but if the
microphone is not connected, “NOT CONNECT” should be selected. The operation of VHF radio
telephone is the same to the microphone.

8.3.2.5 Serial Port Data Configuration

On clicking the button “SERIAL PORT”, the serial port data configuration screen will appear,
referring to fig.8-17. The serial port data configuration includes:
1)ADD: add a serial port to the configuration
2)MODIFY revise a serial port content
3)DELETE: delete a serial port in the configuration
4)COM PORT: the number of communication port which is connected to VDR, thereinto
COM1 ~ COM20 optional

65
SEALANTERN ELECTRONICS CO., LTD

5)BAUD RATE: set the baud rate of the serial port communication
6)TIMEOUT(SEC): time delay of the alarm
7)NAME: input serial nane
8)FILE: document name which serial recording data saved
9)NMEA MESSAGE: data message of NMEA0183
10)HEADER: data messages to be added
11)USE: choose one among COM5~COM16, and run it
12)UNUSE: choose one among COM5~COM16, and stop it

Serial port have been configurated in accordance with the relevant requirements before out of
factory , users only need to stop or use the serial port in the process of installation and debugging,
it is better not to modify, the operational method as following:
1 Use or unuse :, click the “use” to use the serial port, or click “unuse” stop it.
2.Change : choose the port in the list ,to modify related content, including serial port number, baud
rate, alarm delay,serial port name, save the file name and statement, click the Modify to finish.
3.Add :choose the blank in the list, to set up serial port related content, including serial port
number, baud rate, alarm delay, serial port name, save the file name and statements, click ADD to
finish.
4.Delete :choose the port in the list ,and click Delete to finish.
5.Add or delete the new statement :write statement which not exist in the NMEA message to the
HEADER , click ADD to finish on the right side;Check the statement, click delete to finish.

66
SEALANTERN ELECTRONICS CO., LTD

Fig.8-17 Serial port Channel Configuration

8.3.2.6 The configuration of analog and switching data

Analog signal setting as shown in fig8-18.


1Modify The applied analog signal properties
2Channel Choose analog connected channel
3Name named analog signal, the drop-down list cannot be entered manually
4Source select signal source equipment ,the drop-down list cannot be entered manually.
5Unit set the analog signal unit (e.g., degree, length, etc.)
6Min/Max set the range of the analog signal
7Signal Min/Max set the analog signal actual voltage or current value range
8Time Out set the analog alarm delay
9Tip set use or unuse analog channels.True for the usef, False to deactivate

Switching signal setting as shown in fig8-19.


1Modify The applied analog signal properties
2Channel Choose analog connection channel
3Name named analog signal, the drop-down list cannot be entered manually
4Time Out set the analog alarm delay
5Tip set use or unuse analog channels.True for the usef, False to deactivate

67
SEALANTERN ELECTRONICS CO., LTD

Fig8-18 the configurated analog data screen

Fig8-19 the configurated analog data screen

8.4 Playback Software Instruction

8.4.1 Click “playback.exe” in the playback folder in the start menu to enter the initiative screen,
shown as figure 8-20, of the VDR playback device. Here, all functions are defaulted as invalid,
and only the loader screen is displayed.

8.4.2 Loader Screen of the Software

The loader screen mainly loads all the recording items of the VDR main controlling software into
the playback device. There are two ways:

1.For the VDR server loading, it is necessary to fill IP address and path of VDR SERVER for data
storage ;
1)the IP address and path of the PDC is 192.168.0.1\share\data and the FPDC is
192.168.0.2\share\data,
2)as well as user name:admin and password :admin to realize the access to the VDR server.
3)Besides the loaded local path, which means the specific local position where the recorded

68
SEALANTERN ELECTRONICS CO., LTD

information downloaded from internet is located and stored, should be filled as well. This path can
be inputted from the textbox directly or selected from the menu bar .
4)Click “OK” to begin the load. .

2.From Local Path

8.4.3 Software Menu

The main screen of the playback device includes the menu bar, tool bar, status bar, control area
and display area.

The menu bar mainly realizes the control for all functions, the tool bar for the shortcut keys, status
bar for the status information, and control area controls the displaying contents of the display area
as well as the display are for the display of the recording information.

Now, a brief introduce about all the screens and functions will be given starting from the menu
bar.

8.4.3.1 File Menu

The file menu includes two sub-menus: select the loading path and exit.

Click the “select loading path” sub-menu, and a loading screen shown as figure 8-20 above will
appear. All recording information can be loaded and fully displayed on the main screen after
setting and loading successfully. The file menu will only be active after the software uninstalling
the current recording and returning to the preparing-for-recording status, but shielded after the
device completed the loading.

Click the “exit” sub-menu to exit the playback device.

69
SEALANTERN ELECTRONICS CO., LTD

fig8-20 Loader Screen of the Software

8.4.3.2 Display Menu


The display menu includes four sub-menus: RADAR CONTROL, AUDIO CONTROL,INFO
CONTROL,AIS CONTROL .

The controlling area will automatically display the radar image controlling screen by clicking the
“RADAR” sub-menu, and select corresponding time information in the page to display the radar
image of the time. Detailed description refers to the software function instruction.

The controlling area will automatically display the audio controlling screen by clicking the
“AUDIO” sub-menu, and select corresponding time information in the page to play all the audio
files from the period to next period. Detailed description refers to the software function
instruction.

The controlling area will automatically display serial port DATA controlling screen by clicking the
“INFO” sub-menu, and select corresponding time information in the page to display all the audio
files from the period to next period. Detailed description refers to the software function
instruction.

70
SEALANTERN ELECTRONICS CO., LTD

The controlling area will automatically display AIS controlling screen by clicking the “AIS”
sub-menu, and select corresponding time information in the page to display all the AIS files from
the period to next period. Detailed description refers to the software function instruction.

8.4.3.3 Configuration Menu

The configuration menu includes one sub-menu, that is, uninstall the current item.

Click the “uninstall the current item” button to uninstall all the current radar images, audio display
and other data, and the device returns to the opening screen. Besides the “select loading path” and
“exit” in the file menu, the other selecting items are invalid and new items can be loaded.

8.4.3.4 Tool Bar

There are 6 shortcut buttons in the tool bar: LOAD, RADAR, AUDIO, AIS, DATA and PLAYALL.
Click the respective button in the tool bar to complete the operations describing above.

8.4.4 Software Function Instruction

The playback device of VDR mainly replays the information recorded by VDR. It includes 2
modules: loading and replay shown as figure 8-21:

LAN Load
Load
Local Load
Signal Channel
Playback Radar Image
Device Play Channels At One Time
Audio Replay
Replay Serial Port Data
Play Channels in Turn
AIS Data Playback
Whole Broadcast

Fig.8-21 Software Function Instruction

The function of the load module has been introduced. The replay module will be introduced in this
chapter.

71
SEALANTERN ELECTRONICS CO., LTD

fig8-22 reply document setting display

8.4.4.1 Radar Image Replay

The controlling screen in the left part of the radar image display is designed as a layered structure.
The files of the first layer are divided for every minute. If there is a sub-layer in a minute file, a “+”
will be displayed in the left. Click “+” of the first layer to display all the radar images in this
minute file, shown as figure 8-23. Click “+” of the second layer to open put the time list of this
minute file, shown as figure 8-24.

72
SEALANTERN ELECTRONICS CO., LTD

fig8-23 Radar Image Control Display – Multi Pictures

fig8-24 Radar Image Control Display – Signal Picture

73
SEALANTERN ELECTRONICS CO., LTD

8.4.4.2 Audio Replay

In the audio display screen, select the time in the time page of the controlling area firstly, and then,
click “Begin” in the display area to automatically enter into the audio files of next time period and
read the opened audio channel in this period as well as the relative options, shown as figure 8-25.

There are 3 ways for replay: signal channel replay, replay channels at one time and replay
channels in turn. No matter which way selected to play, it can control the sound to begin, pause
and stop.

The signal channel replay is set as default, and also can be active by selecting “Play Signal
Channel” in the right upper side of the display area. If “repeat” has been selected, the sounds of
this channel will be repeated to broadcast.

Fig.8-25 Audio Control Display

The replay-channels-at-one-time is active by selecting “Play Channels At One Time” at the right
upper side of the display area. Click “play” to play all the “enabled” channels. If “repeat” has been
selected, the sounds of the “enabled” channels will be repeated to broadcast.

Note: all the selected channels will be controlled synchronously but not broadcast, paused or
stopped individually after selecting the replay-channels-at-one-time.

74
SEALANTERN ELECTRONICS CO., LTD

The replay-channels are active by selecting “Play Channels-in-turn” at the right upper side of the
display area. Then, click the selecting frame of the channels, and the selected channels will appear
in the list frame at the right upper side. Click the controlling button beside the list frame to
broadcast the sounds in each channels sequentially. If “repeat” has been selected, the sounds of the
selected channels will repeat once after its normal broadcast. Use the up and down buttons at the
right side of the list frame to change the broadcast sequence of the channels.

8.4.4.3 AIS Data Replay

In the AIS broadcast screen, select the time information at the time page FILTER firstly, and click
“BEGIN” button, then, the system will automatically display the AIS data in the left side of the
display area and display it in the right side by dynamic image, shown as Fig.8-26. “OUR SHIP ”
shows the information of the ship. “OTHER” shows the information of other ships vicinal to this
ship. The display semidiameter can be selected from the data of the “SCOPE”.

Fig. 8-26 AIS Data

8.4.4.4 Installed Information Reply

Under the Information display screen, show the location of the installed information and
microphone.
As shown in figure 8-27.

75
SEALANTERN ELECTRONICS CO., LTD

fig8-27 installed information display

8..4.4.5 Whole Replay


The control and display of the whole replay are located in the display area.

In the data and whole broadcast screen, click “filter” button at the left upper side of the display
area to enter into the time filtering screen of the whole broadcast, shown as 8-28.

76
SEALANTERN ELECTRONICS CO., LTD

Fig.8-28 Whole Broadcast Display

In the whole broadcast, click “pause” to break off the broadcast or click “stop” to stop the
broadcast.

Note: it is forbidden to enter into the time filtering screen to re-select the starting time during the
broadcast or its pause. Re-selection can only be carried out after stopping the whole broadcast.

8..4.4.6 Port Data Replay

Click on the "Filter" button, select the reply time interval, click on "Begain" to start port data reply.
Then playback the data of date, time, position, heading, water depth, engine order and response,
rudder order and response and so on.
Click "Stop" to stop the current port data reply.

77
SEALANTERN ELECTRONICS CO., LTD

Fig8-29 Port Data Replay Display

78
SEALANTERN ELECTRONICS CO., LTD

9. Long-term storage medium


The long-term storage medium is installed in the Recording Control Unit(RCU) with the capacity
of 512GB and it can store 30-day-long data. It is connected to the USB4 port of the main computer.
Refer to the diagram 9-1:

9.2 Download the data stored in the long-term storage medium


There are 2 ways to download the data that stored in the long-term storage medium.
One is to download the data via Ethernet port. The other is to playback the data stored
in the long-term storage medium via the USB port.

9.2.1 Download data via Ethernet port


Download the data stored in the long-term storage medium by using playback
software, usage of the playback tools refer to step 8.4 playback software instruction.
To do downloading, choose “from VDR Server” in the playback mode choosing
interface of the software, select the path: “192.168.0.100\data”, user name:

79
SEALANTERN ELECTRONICS CO., LTD

“administrator” and the password is null.

Diagram 9-2 Load type choose

9.2.2 Playback via USB port

Dis-assembly the long-term storage medium from the VDR system. Pull down the
data from the USB4 port on the computer, then pull the whole storage medium out of
the installation box.
Connect the USB port of the long-term storage medium to the computer which has
installed playback tool. Playback the data by using the local data playback function of
the software.Refer to step 8.4 for the software instruction.

80
SEALANTERN ELECTRONICS CO., LTD

10.Document Placement Guide


We recommend our customer to place the document that comes with the VDR into the
folder on the chart table. VDR document contains operation manual, installation CD
and playback cable. Placement sequence refer to diagram 10-1.

10-1 Diagram of document placement

81
SEALANTERN ELECTRONICS CO., LTD

11. COMMISSIONING & ANNUAL INSPECTION TEST REPORT

SLT-18C VDR

安装调试&年度检验报告

COMMISSIONING & ANNUAL INSPECTION TEST REPORT

船 名
Vessel Name _______________________________
产品编号
Serial No __________________ ____________
检验日期
Inspection date ____________ __________________
检验人员
Inspected by ____________ _________________ _
公司名称
Company ____________________ ___________
验 船 师
Surveyed by ____________________ ___________
船 级 社
Class Body ____________ ___________________

天 津 市 斯 莱 顿 电 子 有 限 公 司
82
SEALANTERN ELECTRONICS CO., LTD

SEALANTERN ELECTRONICS CO., LTD


A . 准备工作 Preparation

按照图纸和用户手册中的要求,测试之前应提前作好下列工作:
The test is prepared by the following procedure in accordance with operation manual.
步骤 规则
Step Procedure
安装好回放软件至个人电脑中,将电脑与 VDR 主控制箱内 HUB 以太网口连接。
1 Connect a playback or operation-monitoring device installed with the software dedicated for VDR
with the HUB in Recording Control Unit.
开始记录已连接串口设备的数据。
2
Start to record the data connected sensors / devices.
通过操作检验设备输出数据时,记录数据或信号。
3 Record the data and/or signals while the necessary data for operation checking are outputted
from sensors / devices.
使用数据回放设备,检查校验最终记录介质中储存的数据。
4 Check and verify the recording data storage in the storage media using a playback or
operation-monitoring device.

B. 检验 Inspection

1. 组成单元的幸存能力 Survivability of consisting unit


数据保护容器 Protective Data Capsule
No. 规则 Procedure & Specification 结果 Result
数据保护容器表面无裂缝,无盐碱腐蚀,油漆未变色,附着的电缆
无损害。
1
There should be no crack on the surface, salt damage, flooding and damage
of attached cables.
释放装置无损害,无铁锈。
2
Release lever should be able to move without damage or rusting.
商标和文字的可视性。
3
The visibility of making and retro-reflective materials should be clear.
信标开关应当无污秽。
4
The both switches on the beacon should be clear.

电池有效日期确认 Valid Date Confirmation for Batteries


No. 规则 Procedure & Specification 结果 Result
UPS 电池更换的有效终止日期应为一年或以上。
1 The valid expiration date to exchange of the UPS battery should be one (1)
year or more.
数据保护容器水下信标电池更换的有效终止日期应为一年或以上。
2 The valid expiration date to exchange of battery for the underwater beacon
attached to the protective capsule should be one (1) year or more.
上浮式数据保护容器电池更换的有效终止日期应为一年或以上。
3 The valid expiration date to exchange of battery attached to the Float-Free
protective capsule should be one (1) year or more.

静水释放器有效日期确认 Valid Date Confirmation for Hydrostatic Release System


No. 规则 Procedure & Specification 结果 Result
静水释放器更换的有效终止日期应为一年或以上。
1 The valid expiration date to exchange of the Hydrostatic Release System of
Float-Free protective capule should be one (1) year or more.

83
SEALANTERN ELECTRONICS CO., LTD

2. 系统操作的执行 Implementation of system operation


一般操作 General Operation
No. 规则 Procedure & Specification 结果 Result
切断系统供电的船舶供电,VDR 电源管理应切换到电池模式,通过
安装在内部的电池为其供电。
1 On cutting off all the power supply from ship, VDR power management
should shift to battery backup mode, which is to supply power source from
built-in batteries.
切断系统的船舶供电,系统处发光报警,声音报警 2 分钟后自动终
止。
2
On cutting off the power supply from ship’s main, audible and visible alarms
should be happened. (Audible alarm is terminated with 2 minutes expired.)
系统工作在正常状态,接线正确,采集数据信号,无故障指示。
As long as the system operates in normal condition with acquiring all
3
necessary data and signals and with correct wiring, no error should be
happened.
启动 VDR 系统后,控制软件自动运行,并可以通过报警面板上
“Recording”查看。
4 After starting to run the VDR system, the recording process should be
automatically started without operation. The automatic starting can be
checked by “RECORDING” lamp in alarm panel.
保存在数据保护容器中的数据应能够自动给予备份。
5
Data recording into capsule should be able to be saved to backup media.
保存在上浮式数据保护容器中的数据应能够自动给予备份。
6 Data recording into Float-free capsule should be able to be saved to backup
media.

3. 传感设备及记录数据的有效性检验
Validity and verification of recording data / Serviceability check of sensors and devices

检查 VDR 系统连接的传感器及设备的精度和适用性。确认数据的有效性,验证传感器及从
设备中采集到的数据,与系统图纸中描述的连接设备和接口的状况相一致。
Confirm validation and verify recording data acquired from sensors / devices in coinciding
to the connected equipment and interface condition that are described in final drawing
(last plan). In addition, check serviceability and accuracy of sensors and/or devices
connected to VDR system.
传感器和设备数据 Sensor / device data
No. 规则 Procedure & Specification 结果 Result
采集和记录日期和时间数据,数据当采集精确。
Data and time data should be acquired and recorded. The recorded data
should be accurate in acquisition.
1 输出设备:
Output from
连接端口:
Interface
采集和记录船舶位置数据,数据采集精确。
Ship’s position data should be acquired and recorded. The recorded data
should be accurate in acquisition.
2 输出设备:
Output from
连接端口:
Interface

84
SEALANTERN ELECTRONICS CO., LTD

采集和记录船速(相对地或相对水)数据,数据采集精确。
Ship speed data (either over-the-ground or through-water) should be
acquired and recorded. The recorded data should be accurate in acquisition.
3 输出设备:
Output from
连接端口:
Interface
采集和记录船艏向数据,数据采集精确。
Ship’s heading data should be acquired and recorded. The recorded data
4 should be accurate in acquisition.
输出设备 Output from:
连接端口 Interface:
通过回音探测仪采集和记录深度数据,数据采集精确。
Water depth data via echo sounder should be acquired and recorded. The
recorded data should be accurate in acquisition.
5 输出设备:
Output from
连接端口:
Interface
采集和记录驾驶室主报警数据,VDR 定义记录的数据。
Bridge main alarms, which are forced to indicate on bridge should be
acquired and recorded. Acquired alarms are specified in the final plan of
VDR system.
6
输出设备:
Output from
连接端口:
Interface
采集和记录 AIS 数据,记录的数据应当采集精确。
AIS data should be acquired and recorded. The recorded data should be
accurate in acquisition.
7 输出设备:
Output from
连接端口:
Interface
采集和记录防火门和水密门开关状态数据,记录的数据应当精确。
Fire doors and watertight doors status data should be acquired and
recorded. The recorded data should be accurate in acquisition.
8 输出设备:
Output from
连接端口:
Interface
采集和记录船体开口(门)状态数据,记录的数据应当精确。
Hull door status data should be acquired and recorded.
输出设备:
9
Output from
连接端口:
Interface
采集和记录轮机命令和响应数据,记录的数据应当精确。
Engine response data should be acquired and recorded. The recorded data
should be accurate in acquisition.
10 输出设备:
Output from
连接端口:
Interface

85
SEALANTERN ELECTRONICS CO., LTD

采集和记录操舵命令和响应数据,记录的数据应当精确。
Rudder order& response data should be acquired and recorded. The
recorded data should be accurate in acquisition.
11 输出设备:
Output from
连接端口:
Interface
采集和记录加速度和船体应力数据,记录的数据应当精确。
Hull stress monitoring data should be acquired and recorded. The recorded
data should be accurate in acquisition.
12 输出设备:
Output from
连接端口:
Interface
采集和记录风速和风向数据,记录的数据应当采集精确。
Wind direction and speed data should be acquired and recorded. The
recorded data should be accurate in acquisition.
13 输出设备:
Output from
连接端口:
Interface
其他:
Other Device
输出设备:
14
Output from
连接端口:
Interface
其他:
Other Device
输出设备:
15
Output from
连接端口:
Interface
其他:
Other Device
输出设备:
16
Output from
连接端口:
Interface
其他:
Other Device
输出设备:
17
Output from
连接端口:
Interface
其他:
Other Device
输出设备:
18
Output from
连接端口:
Interface
其他:
Other Device
19
输出设备:
Output from

86
SEALANTERN ELECTRONICS CO., LTD

连接端口:
Interface
其他:
Other Device
输出设备:
20
Output from
连接端口:
Interface
其他:
Other Device
输出设备:
21
Output from
连接端口:
Interface
其他:
Other Device
输出设备:
22
Output from
连接端口:
Interface
注:超出设备请手工添加表项填写。
Note: Please manually add tables if not enough.
4. 麦克风及甚高频音频 Voice Communication via Microphone and VHF

连续记录驾驶室麦克风和甚高频声音;并回放声音数据。
Audio signals at microphones and VHF placed in bridge should be recorded continuously.
And audio signals should be played back.

功能 Function
No. 规则 Procedure & Specification 结果 Result
No.1 麦克风 Microphone 1
位 置:
Location
回放通道 1 No.2 麦克风 Microphone 2
位 置:
Channel 1 Location
No.3 麦克风 Microphone 3
位 置:
Location
No.4 麦克风 Microphone 4
位 置:
Location
回放通道 2 No.5 麦克风 Microphone 5
位 置:
Channel 2 Location
No.6 麦克风 Microphone 6
位 置:
Location
No.7 麦克风 Microphone 7
位 置:
回放通道 3
Location
No.8 麦克风 Microphone 8
Channel 4
位 置:
Location
回放通道 No.1 VHF

87
SEALANTERN ELECTRONICS CO., LTD

VHF 设 备:
Device
Channel No.2 VHF
VHF 设 备:
Device
No.3 VHF
设 备:
Device
5. 雷达/电子海图视频图像 Radar/ECDIS Display Image

VDR 系统连续记录雷达/电子海图视频信号;并回放图像数据。
Video signals from selected Radar/ECDIS equipment connected with VDR system should
be recorded continuously. And audio signals should be played back.
雷达视频图像 Radar Display Image
No. 规则 Procedure & Specification 结果 Result
位 置:
Location
No. 1 Radar
设 备:
Device
位 置:
Location
No. 2 Radar
设 备:
Device
位 置:
Location
No.3 ECDIS
设 备:
Device
位 置:
Location
No.4 ECDIS
设 备:
Device

88